I n4f August 7, 1981 f2 AUG 17l9810_
TO ALL APPLICANTS/LICENSEES REFERENCING BWR OWNERS GROUP RESP t 74- ITEM II.K.3.44 Gentlemen:
SUBJECT: NUREG-0737, ITEM II.K.3.44-EVALUATION OF ANTICIPATED TRANSIENTS
COMBINED WITH SINGLE FAILURE (Generic Letter No. 81-32)
The staff has completed its review of the General Electric BWR Owner Group report dated December 29, 1980 pertaining to the subject NUREG-0737 item.
This report was prepared for the participating applicants/licensees identi- fied in the enclosure.
This is to advise you that we have found the response contained in this report to be acceptable on a generic basis. However, in order to confirm the applicability of this report to your facility we request that you pro- vide verification that the assumptions and initial conditions used in the analyses are representative for your plant(s). Licensees and applicants are to provide this information according to the following schedule:
a. Licensees of operating plants within 90 days of receipt of this letter, b. Applicants for operating licenses within 90 days of receipt of this letter and c. The remaining participating utilities within 30 days of docketing of the FSAR.
If the conditions and assumptions used in the analyses are not representative, the licensee should identify the major design differences between the plant analy~ed and the licensee's plant. A qualitative assessment of the effect these differences have on the analyses can be offered by the licensee; however, if this assessment lacks technical support, a schedule for providing plant specific analyses will be required. For applicants for operating licenses the completion dates for any required analyses should be consistent with your review schedule.
The above information is requested in accordance with Sections 103.b(3) and
161.c of the Atomic Energy Act of 1954, as amended. The request for informa"
tion was approved by OMB under clearance number 3150-0065 which expires June 30, 1983. Comments on burden and duplication may be directed to the Office of Management and Budget, Reports Management, Room 3208, New Executive Office Building, Washington, 0. C. - t Mr. B. Siegel has been assigned the lead on Action Plan Item II.K.3.44.
Should you have any questions regarding this request please feel free to t E Jw OFFICEO
,I, ,p.1p SUNME
DR28c74eo*-----------.. . . . . . .. ........... - ..I..................... ..................... ..................... ...................... ....................
SURNAME4....8108240477 910807 DATE PDR ADOCK
P
..................
09 I.............
+04W
PDR O .....................................................
,,........I............. ............ ..................... ................ ..... ............... ..... I.......... ...............
_._ .___ _.___
NRC FORM 318 410/80) NRCM 0240
- USGPO: 1980-329-824 OFFICIAL RECORD COPY
- 1 At;
To ALL Applicants/Licensees Referencing BWR Owners Group Response to HLREG-
0737 Item II.K.3.44 _ 2.
contact him at (301) 492,4909. Your time and efforts are appreciated.
Sincerely, Original signed by Darrell G. Elselxl Darrell G. Eisenhut, Director Division of Licensing Office of Nuclear Reactor Regulation Enclosure:
Listing of Applicants/
Licensees cc w/enclosure:
Service Lists Distribution:
Docket File (1)
NRC PDR (1)
L PDR (1)
TERA (1)
NSIC (1)
DL ADs (3)
ORBCs (5)
ORAB (1)
SEPB (1)
ORB LAs (6)
OELD (5)
IE (7)
JWetmore CHarwood R. Diggs PWooley Gray Files (1 ea.)
ACRS (10)
DEisenhut PCheck A
'..O.RS:DL AB:OR:DL'I
B i7f8. TIppol ito TNovak RTA o
..
II .... *T7IPofii..... *-7/^^-fa........ *7 $ f81----- 7-AW P .-----*7-f , 4 ........
... 7ft-1 ....... .... /...
.....................
NRC FORM 318 FORM 318 IOI80)
NRC110/80) 8240
NRCM G240
NRCM OFFICIAL RECORD COPY USGPO: 1980-329-824
., USGPO: 1980-329-824 O FFICIA L R EC O RD C OP Y
~A
- - P
k Enclosure APPLICANTS/LICENSEES PARTICIPATING IN BWR OWNERS GROUP
GENERAL RESPONSE TO NUREG-0737, II.K.3.44 Boston Edison Pilgrim 1 Carolina Power & Light Brunswick 1 & 2 Commonwealth Edison LaSalle 1 & 2, Dresden 1-3, Quad Cities 1 & 2 Georgia Power Hatch 1 & 2 Iowa Electric Light & Power Duane Arnold Jersey Central Power & Light Oyster Creek 1 Niagara Mohawk Power Nine Mile Point 1 & 2 Nebraska Public Power District Cooper Northeast Utilities Millstone 1 Philadelphia Electric Peach Bottom 2 & 3, Limerick 1 & 2 Power Authority of the State of New York FitzPatrick Tennessee Valley Authority Browns Ferry 1-3, Hartsville 1-4, Phipps Bend 1 & 2 Vermont Yankee Nuclear Power Vermont Yankee Detroit Edison Enrico Fermi 2 Mississippi Power & Light Grand Gulf 1 & 2 Pennsylvania Power & Light Susquehanna 1 & 2 Washington Public Power Supply System Hanford 2 Cleveland Electric Illuminating Perry 1 & 2 Houston Lighting & Power Allens Creek Illinois Power Clinton Station 1 & 2 Public Service of Oklahoma Black Fox 1 & 2 Long Island Lighting Shoreham Northern States Power Monticello