Kewaunee Nuclear Power Plant N490 Highway 42 Kewaunee, WI 54216-9511 920.388.2560 Point Beach Nuclear Plant 6610 Nuclear Road Two Rivers, WI 54241 920.755.2321 Kewaunee / Point Beach Nuclear Operated by Nuclear Management Company, LLC 10 CFR 50.36 NRC 2002-0010 January 17, 2002 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Dockets 50-266 and 50-301 Point Beach Nuclear Plant, Units 1 and 2 TECHNICAL SPECIFICATION BASES B 3.3.1 REVISION Ladies/Gentlemen:
Nuclear Management Company, LLC (NMC), licensee for the Point Beach Nuclear Plant (PBNP) Units 1 and 2, hereby submits a revision to the following Bases for Technical Specifications (TS): B 3.3.1, "RPS Instrumentation". A description of the changes is provided in Attachment I.
These changes have been screened for evaluation pursuant to the requirements of 10 CFR 50.59 in accordance with approved PBNP procedures and were determined to be acceptable.
Attachment II provides a clean copy of the affected TS Bases page indicating the changes.
Sincerely, Thomas H. Taylor Plant Manager RDS/kmd Attachments:
II Description and Assessment of Changes Revised Technical Specifications Bases Page cc:
NRC Regional Administrator NRC Resident Inspector NRC Project Manager PSCW Committed to Nuclear Excellence D
NRC 2002-0010 Attachment I Page 1 of 2 DESCRIPTION AND ASSESSMENT OF CHANGES TECHNICAL SPECIFICATION BASES B 3.3.1 REVISION POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2
NRC 2002-0010 Attachment I Page 2 of 2
1.0 INTRODUCTION
Nuclear Management Company, LLC (NMC), licensee for the Point Beach Nuclear Plant (PBNP) Units 1 and 2, hereby submits a revision to the following Bases for Technical Specifications (TS): B 3.3.1, "RPS Instrumentation".
2.0 DESCRIPTION
AND ANALYSIS TS Limiting Condition for Operation (LCO) 3.3.1, Required Action D.1, requires an inoperable channel to be placed in the trip condition in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. The Bases discussion of the Completion Time requirements for LCO 3.3.1, Required Action D.1, had incorrectly stated this time as 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. Therefore, this statement was revised to correct the 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to accurately reflect the requirements of TS LCO 3.3.1, Required Action D.1.
NRC 2002-0010 Attachment II Page 1 of 2 REVISED TECHNICAL SPECIFICATIONS BASES PAGE (incorporating proposed changes)
RPS Instrumentation B 3.3.1 BASES ACTIONS (continued)
The additional hour provides sufficient time to accomplish the action in an orderly manner. With the RTBs open, the Manual Reactor Trip Function is no longer required.
D.1 and D.2 Condition D applies to the following reactor trip Functions:
"* Power Range Neutron Flux-High;
"* Power Range Neutron Flux-Low;
"* Overtemperature AT;
"* Overpower AT;
"* Pressurizer Pressure-High;
"* SG Water Level-Low Low; and
"* SG Water Level - Low coincident with Steam Flow/Feedwater Flow Mismatch.
A known inoperable channel must be placed in the tripped condition within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. Placing the channel in the tripped condition results in a partial trip condition requiring only one-out-of-two logic for actuation of the two-out-of-three trips and one-out-of-three logic for actuation of the two-out-of-four trips.
If the inoperable channel cannot be placed in the tripped condition within the specified Completion Time, the unit must be placed in a MODE where these Functions are not required OPERABLE. An additional 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> is allowed to place the unit in MODE 3. Six hours is a reasonable time, based on operating experience, to place the unit in MODE 3 from full power in an orderly manner and without challenging unit systems.
E.1 and E.2 Condition E applies to the Underfrequency Bus A01 and A02 trip function. With one channel inoperable, the inoperable channel must be placed in the tripped condition within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. Placing the channel in the tripped condition results in a partial trip condition requiring only one additional channel to initiate a reactor trip above the P-7 setpoint. The 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> to place the channel in the tripped condition is necessary due to plant design requiring maintenance personnel to effect the trip of the 12/19/01 B 3.3.1-29 Point Beach