NL-22-0499, Registration of Spent Fuel Cask Use
| ML22178A194 | |
| Person / Time | |
|---|---|
| Site: | Hatch, Vogtle, 07200036, 07201039, Holtec |
| Issue date: | 06/27/2022 |
| From: | Gayheart C Southern Nuclear Operating Co |
| To: | Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation |
| References | |
| NL-22-0499 | |
| Download: ML22178A194 (2) | |
Text
._ Southern Nuclear June 27, 2022 Cheryl A. Gayheart Regulatory Affairs Director 3535 Colonnade Parkway Birmingham, AL 35243 205 992 5316 tel 205 992 7601 fax cagayhea@southernco.com Docket Nos.: 50-321 50-366 72-1039 50-424 50-425 72-36 NL-22-0499 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Ladies and Gentlemen:
Edwin I. Hatch Nuclear Plant Vogtle Electric Generating Plant Registration of Spent Fuel Cask Use Southern Nuclear Operating Company (SNC) operates the Edwin I. Hatch Nuclear Plant (Hatch) Independent Spent Fuel Storage Installation (ISFSI) and the Alvin W.
Vogtle Electric Generating Plant (Vogtle) ISFSI in accordance with the general license provisions of 10 CFR 72.210. The requirements of 10 CFR 72.212(b)(2) include the registration of a spent fuel cask within 30 days of using a cask for the storage of spent nuclear fuel. Accordingly, SNC provides the following registration information associated with (2) HI-STORM 100 spent fuel cask systems recently placed into storage at the Hatch ISFSI and (1) HI-STORM 100 spent fuel cask systems placed into storage at the Vogtle ISFSI.
I Site II Hatch ISFSI II Vogtle ISFSI I
License Unit 1 - DPR-57, Unit 1 - NPF-68, Nos.
Unit 2 - NPF-5 Unit 2 - NPF-81 Cask 72-1014, 72-1014, 72-1014, Certificate Amendment 11 Amendment 11 Amendment 9 R1 Cask HI-STORM 100S, HI-STORM 100S, HI-STORM 100S, Model Version B Version B Version B MPC 578 655 687 Serial Number Overpack 1062 1234 1424 Serial Number Number of 68 68 32 Fuel Bundles Placed in 5/27/2022 6/10/2022 6/17/2022 Service
U.S. Nuclear Regulatory Commission NL-22-0499 Page2 The addition of the above casks results in the following totals for the Vogtle and Hatch ISFSI:
Hatch ISFSI: 3 HI-STAR 100 Systems and 88 HI-STORM 100 Cask Systems Vogtle ISFSI: 48 HI-STORM 100 Cask Systems This letter contains no regulatory commitments. If you have any questions, please contact Ryan Joyce at 205.992.6468.
Respectfully submitted, Cheryl yheart Regulatory Affairs Director CAG/dsp/cbg cc:
Regional Administrator, Region II NRR Project Manager-Hatch, Vogtle 1 & 2 Senior Resident Inspector - Hatch, Vogtle 1 & 2 RType: PP1.006