Responses to Requests for Additional Information (Rais) for the Revalidation Recommendation for the Model No. JMS-87Y-18.5T, Docket No. 71-3004, June 27, 2023
Date released: 02/16/2024 Download: ML24043A216


Letter Dated 6/20/23 from K Tsuchiya (Jaea) to R W Boyle (Dot), Responses to Requests for Additional Information for the Revalidation Recommendation for the Model No. JMS-87Y-18.5T, Japanese Certificate of Competent Authority No. J/2044/B(U
ML24043A224
Person / Time
Site: 07103004
Issue date: 06/20/2023
From: Tsuchiya K
Govt of Japan, Atomic Energy Agency
To: Garcia-Santos N
Storage and Transportation Licensing Branch
References
001794, EPID L-2023-DOT-0005
Download: ML24043A224 (1)
Letter Dated 6/27/23 from Rboyle (DOT) to Ngarcia Santos (NRC) Responses to Requests for Additional Information for the Revalidation Recommendation for the Model No. JMS-87Y-18.5T, Japanese Certificate of Competent Authority No. J/2044/B(U)
ML24043A223
Person / Time
Site: 07103004
Issue date: 06/27/2023
From: Boyle R
US Dept of Transportation (DOT), Office of Hazardous Materials Safety
To: Garcia-Santos N
Storage and Transportation Licensing Branch
References
001794, EPID L-2023-DOT-0005
Download: ML24043A223 (1)
Enclosure 1 - Responses to Requests for Additional Information (Rais) for the Revalidation Recommendation for the Model No. JMS-87Y-18.5T, Japanese Certificate of Competent Authority No. J/2044/B(U)F, Docket No. 71-3004, June 27, 2023
ML24043A222
Person / Time
Site: 07103004
Issue date: 06/27/2023
From: Boyle R, Neely R, Tsuchiya K
Edlow International Co, US Dept of Transportation (DOT), Office of Hazardous Materials Safety
To: Garcia-Santos N
Storage and Transportation Licensing Branch
References
001794, EPID L-2023-DOT-0005
Download: ML24043A222 (11)
Affidavit 6/26/23 - Responses to Requests for Additional Information (Rais) for the Revalidation Recommendation for the Model No. JMS-87Y-18.5T, Japanese Certificate of Competent Authority No. J/2044/B(U)F, Docket No. 71-3004
ML24043A220
Person / Time
Site: 07103004
Issue date: 06/26/2023
From: Tsuchiya K
JAEA
To: Boyle R W
Office of Nuclear Material Safety and Safeguards
References
001794, EPID L-2023-DOT-0005
Download: ML24043A220 (1)