Cadillac Castings, Inc., NRC Forms 591M and 592M, Inspection Report 03032072/2023001
ML23360A162
Person / Time
Site: 03032072
Issue date: 12/22/2023
From: Jason Dykert, Shirley E
NRC/RGN-III
To: Olson E
Cadillac Castings
References
IR 2023001
Download: ML23360A162 (1)


See also: IR 07200202/2030001

Text

NRC FORM 591M

(04-2022)

Materials Inspection Report

U.S. NUCLEAR REGULATORY COMMISSION

Page 1 of 1

Add Continuation Page

1. Licensee/Location Inspected:

Cadillac Castings, Inc.

1500 Fourth Ave.

Cadillac, MI 49601

Report Number(s) 2023-001

2. NRC/Regional Office

Region III

U. S. Nuclear Regulatory Commission

2443 Warrenville Road, Suite 210

Lisle, IL 60532-4352

3. Docket Number(s)

030-32072

4. License Number(s)

21-26282-01

5. Date(s) of Inspection

November 29, 2023

LICENSEE:

The inspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the

Nuclear Regulatory Commission (NRC) rules and regulations and the conditions of your license. The inspection consisted of selective

examinations of procedures and representative records, interviews with personnel, and observations by the inspector. The inspection findings

are as follows:

1. Based on the inspection findings, no violations were identified.

2. Previous violation(s) closed.

3. During this inspection, certain of your activities, as described below and/or attached, were in violation of NRC requirements, and

were assessed at Severity Level IV, in accordance with the NRC Enforcement Policy.

B. The following violation(s) is/are being cited in accordance with NRC Enforcement Policy. This form is a NOTICE OF VIOLATION,

which may be subject to posting in accordance with 10 CFR 19.11.

(Violations and Corrective Actions)

Statement of Corrective Actions

I hereby state that, within 30 days, the actions described by me to the Inspector will be taken to correct the violations identified. This statement of corrective

actions is made in accordance with the requirements of 10 CFR 2.201 (corrective steps already taken, corrective steps which will be taken, date when full

compliance will be achieved). I understand that no further written response to NRC will be required, unless specifically requested.

A. The violation(s), specifically described to you by the inspector as non-cited violations, are not being cited because they were self-

identified, non-repetitive, corrective action was or is being taken, and the remaining criteria in the NRC Enforcement Policy

were satisfied.

(Non-cited violation(s) was/were discussed involving the following requirement(s)

TITLE

NRC INSPECTOR

PRINTED NAME

SIGNATURE AND DATE

LICENSEE'S

REPRESENTATIVE

Jason Dykert; Earlon Shirley

BRANCH CHIEF

Jason C. Dykert

Digitally signed by Jason C. Dykert

Date: 2023.12.04 09:12:44 -07'00'

5KH[(GZDUGV

Digitally signed by Rhex A. Edwards

Date: 2023.12.22 07:05:56 -06'00'

NRC FORM 592M

(10-04-2022)

U.S. NUCLEAR REGULATORY COMMISSION

Materials Inspection Record

Page 1 of 1

NRC Form 592M (10-04-2022)

1. Licensee Name:

Cadillac Castings, Inc.

2. Docket Number(s):

030-32072

3. License Number(s)

21-26282-01

4. Report Number(s):

2023-001

5. Date(s) of Inspection:

11/29/2023

6. Inspector(s):

Jason Dykert; Earlon Shirley

7. Program Code(s):

03120

8. Priority:

5

9. Inspection Guidance Used:

IP 87124

10. Licensee Contact Name(s):

Erik Olson - RSO

11. Licensee E-mail Address:

eolson@cadillaccasting.com

12. Licensee Telephone Number(s):

231-779-9600

13. Inspection Type:

Initial

Routine

Announced

Non-Routine

Unannounced

14. Locations Inspected:

Hybrid

Main Office

Field Office

Temporary Job Site

Remote

15. Next Inspection Date (MM/DD/YYYY):

11/29/2028

Normal

Reduced

Extended

No change

16. Location(s) Inspected List:

1500 Fourth Avenue, Cadillac, MI

17. Scope and Observations:

This was an assist inspection for Region III. The last routine inspection in 2018 identified 2 SLIV violations, for failure

to perform leak tests at least once every three years, and failing to perform annual audits each year. Corrective

actions for these violations were reviewed during this inspection. Cadillac Castings possessed one fixed gauge, a

Thermo Process Instruments 5201, for monitoring the level of raw material going into a melting furnace.

The inspectors interviewed the RSO and observed the installed gauge in use. Area postings were adequate,

independent surveys indicated the gauge shielding was intact as area dose rates were minimal. The inspectors

observed the RSO properly collect samples for leak test analysis and perform a shutter test. The inspectors

reviewed records of previous leak test results, which had been completed as required since the last inspection. The

RSO had a work order generated every six months to ensure physical inventory and shutter tests were performed as

required. The RSO also performed audits of the program each time the work order was generated, and wrote notes

on the work order form to document the audit. Both violations from 2018 are considered closed.

The inspectors noted that the licensee's fixed gauge had been exchanged by the manufacturer in 2011 with a

generally licensed device (s/n B5414) that is still listed in GLTS under recipient code GL-60803. The licensee has

kept this gauge under their specific license and covered the GL label as permitted under 10 CFR 31.5(c)(8)(iii)(B).

However, the licensee is considering terminating the specific license and reverting to possessing the gauge under a

general license as permitted by 10 CFR 31.5(c)(9), and would make the required report if such a transfer occurred.

The RSO stated that they would plan to coordinate any potential future efforts with Region III licensing staff.

No violations of NRC requirements were identified as a result of this inspection.