Industry / NRC Materials Programs Technical Information Exchange Advanced Manufacturing Technologies Carolyn Fairbanks U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of New and Renewed Licenses Vessels and Internals Branch June 14-15, 2023

Advanced Manufacturing Technologies

  • Techniques and material processing methods

- Not traditionally used in the U.S. nuclear industry

- Not formally standardized/codified by the nuclear industry

- AMTs can include new ways to fabricate or join components, surface treatments, or other processing techniques to provide a performance or operational benefit.

2

Examples of U.S. Applications installed under 10 CFR 50.59 3

Channel Fastener

  • Browns Ferry Unit 2
  • 316L stainless steel - LPBF
  • Byron Unit 1
  • 316L stainless steel - LPBF

NRC AMT Action Plan, Rev. 1 (ADAMS ML19333B980)

NRCs initial focus areas Laser powder bed fusion (LPBF)

Laser direct energy deposition (L-DED)

Cold spray (CS)

Electron beam welding (EBW)

Power metallurgyhot isostatic pressing (PM-HIP) 4

  • Technical Preparedness

Technical Letter Reports (National Laboratories)

NRC Technical Assessments

  • Regulatory Preparedness

Draft Guidelines Documents - technology specific

Draft Review Guidelines - generic

Implementation Using the 50.59 Process for AMTs Communications and Knowledge Management

Engagement with industry, codes & standards, research organizations, international

Staff development

  • new reactor fuel technologies are addressed outside the AMT Action Plan

Action Plan Products - Technical Preparedness 5

LPBF ML20351A292 L-DED ML21301A077 Cold Spray ML21263A105 Final Guidance for Initial AMTs (potential future effort)

PM-HIP ML22164A437 EBW ML22143A927 Technical Letter Reports & Assessments LPBF ML21074A040 L-DED ML22143A951 Cold Spray ML22143A952 PM-HIP EBW Technology-Specific Draft Review Guidelines Implementation using 10 CFR 50.59 Process ML21155A043 Assessment of Regulatory Guidance ML20233A693 Draft Guidelines Document for AMTs ML21074A037 NDE Gap Analysis ML20349A012 Modeling Gap Analysis ML20269A301 ML20350B550 NRC Staff-developed Contractor-developed Legend Generic Guidelines

& Assessments

NRC Activities -

Moving Forward

  • Research
  • NDE confirmatory efforts on AMT components, mock-ups, welds
  • Assessment of additional technologies: Arc--DED and diode laser cladding
  • Evaluation of long-term performance, including environmental effects (e.g.,

irradiation, corrosion)

  • Participation in ASME Code activities
  • NRC AMT Workshop: October 24-26, 2023 6

NRC Points-of-Contact & Additional Information Office of Nuclear Regulatory Research Isaac Anchondo-Lopez, Carol Nove NDE of AMT isaac.anchondo-lopez@nrc.gov carol.nove@nrc.gov Eric Focht Overall AMT Agency Efforts eric.focht@nrc.gov Rob Tregoning Senior Level Technical Advisor robert.tregoning@nrc.gov Office of Nuclear Reactor Regulation Carolyn Fairbanks Overall AMT Agency Efforts carolyn.fairbanks@nrc.gov David Rudland Senior Level Technical Advisor david.rudland@nrc.gov John Wise Senior Level Technical Advisor john.wise@nrc.gov NRC AMT website https://www.nrc.gov/reactors/power/amts.html