0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7$%/(2)&217(176

6HFWLRQ

3DJH

,

(YDOXDWLRQ&ULWHULD

,

'HILQLWLRQRI7HUPV

,

$VVXPSWLRQV

7DEOH,

9ROXPH'HVFULSWLRQVIRU+(/%VLQWKH5HDFWRU%XLOGLQJ

7DEOH,

9ROXPH'HVFULSWLRQVIRU+(/%VLQWKH7XUELQH%XLOGLQJ

,

+LJK(QHUJ\\6\\VWHPVDQG3LSLQJ

,

+LJK(QHUJ\\/LQHDQG6\\VWHP'HVFULSWLRQV

,

0DLQ6WHDP6\\VWHP

,

)HHGZDWHU6\\VWHP

,

&RQGHQVDWH6\\VWHP

,

+3&, 6WHDP 6\\VWHP

,

5&,& 6WHDP 6\\VWHP

,

5HDFWRU:DWHU&OHDQXS 5:&8 6\\VWHP

,

,QVWUXPHQWDQG6DPSOH/LQHV

,

&RUH6SUD\\6\\VWHP

,

5HVLGXDO+HDW5HPRYDO 5+5 6\\VWHP

,

+3&, :DWHU 6\\VWHP

,

5&,& :DWHU 6\\VWHP

,

6WDQGE\\/LTXLG&RQWURO

,

2IIJDV6\\VWHP

,

&RQWURO5RG'ULYH6\\VWHP

,

=LQF2[LGH,QMHFWLRQ6\\VWHP *(=,3 

,

+LJK(QHUJ\\/LQH'HVLJQDWLRQ/LVW

7DEOH,

+LJK(QHUJ\\3LSLQJ/LVW

,

%UHDN$QDO\\VLV

,

6HOHFWLRQRI%UHDN/RFDWLRQV

,

&ODVV, /LQHVIRUZKLFKSLSLQJDQDO\\VHVWKDWLQFOXGHVVHLVPLFKDVEHHQ

SHUIRUPHG 

,

&ODVV,, /LQHVIRUZKLFKQRVHLVPLFDQDO\\VHVKDVEHHQSHUIRUPHG 

,

%UHDNVLQ0RGHUDWH(QHUJ\\DQGRU1RQ+LJK(QHUJ\\/LQHV

,

%UHDN7\\SHV

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

+(/%,QWHUDFWLRQV

,

3LSH:KLS(IIHFWV

,

-HW,PSLQJHPHQW(IIHFWV

,

)ORRGLQJ(IIHFWV

,

(QYLURQPHQWDO(IIHFWVDQG&RPSDUWPHQW3UHVVXUL]DWLRQ

,

6\\VWHP%UHDN/RFDWLRQV

,

6DIH6KXWGRZQ5HTXLUHPHQWV5HIHUHQFHDQG

,

6DIH6KXWGRZQ6\\VWHPV

,

6FUDPDQG,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQ3HULRG

,

3RVW,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQ&RQWDLQPHQW&RROLQJDQG'HFD\\

+HDW5HPRYDO3HULRGV

,

'HVFULSWLRQRI6DIH6KXWGRZQ3DWKV

,

6DIH6KXWGRZQ6\\VWHP&RPSRQHQW/RFDWLRQV

,

5HDFWRU3URWHFWLRQ6\\VWHP

,

&RQWURO5RG'ULYH6\\VWHP

,

+LJK3UHVVXUH&RRODQW,QMHFWLRQ +3&, 6\\VWHP

,

5HDFWRU3UHVVXUH5HOLHI6\\VWHP

,

5HVLGXDO+HDW5HPRYDO 5+5 6\\VWHP

,

&RUH6SUD\\ &6 6\\VWHP

,

5+56HUYLFH:DWHU6\\VWHP

,

5HDFWRU&RUH,VRODWLRQ&RROLQJ 5&,& 6\\VWHP

,

6KXWGRZQ,QVWUXPHQWDWLRQ

,

(PHUJHQF\\6HUYLFH:DWHU6\\VWHPV

,

(PHUJHQF\\'LHVHO*HQHUDWRU(PHUJHQF\\6HUYLFH:DWHU6\\VWHP

,

(PHUJHQF\\)LOWUDWLRQ7UDLQ(PHUJHQF\\6HUYLFH:DWHU6\\VWHP

,

(PHUJHQF\\'LHVHO*HQHUDWRUVDQG$X[LOLDULHV

,

$X[LOLDU\\3RZHU'LVWULEXWLRQ6\\VWHPV

,

'&3RZHU6\\VWHPV

,

+9$&6\\VWHPV

7DEOH,

6DIH6KXWGRZQ&RPSRQHQWV$YDLODEOH

,

+(/%DQG6DIH6KXWGRZQ(YDOXDWLRQ

,

&RPSOLDQFH(YDOXDWLRQ 5HIHUHQFHDQG 

,

,GHQWLILFDWLRQRI3RWHQWLDO7DUJHWV

,

6LQJOH$FWLYH)DLOXUH(YDOXDWLRQ

,

+(/%(YDOXDWLRQVE\\6\\VWHP

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

0DLQ6WHDP6\\VWHP

,

0DLQ6WHDP&KDVH 9ROXPH 

,

6-$(5RRP 9ROXPH 

,

&RQGHQVHU$UHD 9ROXPH 

,

7XUELQH2SHUDWLQJ)ORRU 9ROXPH 

,

)HHGZDWHU6\\VWHP

,

5HDFWRU)HHGZDWHU3XPS$UHD9ROXPHVDQG

,

7XUELQH%XLOGLQJ3LSH&KDVH 9ROXPH 

,

7XUELQH2SHUDWLQJ)ORRU 9ROXPH 

,

0DLQ6WHDP&KDVH 9ROXPH 

,

&RQGHQVHU$UHD 9ROXPH 

,

&RQGHQVDWH6\\VWHP

,

&RQGHQVHU$UHD 9ROXPH 

,

7XUELQH%XLOGLQJ3LSH&KDVH 9ROXPH 

,

5HDFWRU)HHGZDWHU3XPS$UHD 9ROXPHVDQG 

,

+LJK3UHVVXUH&RRODQW,QMHFWLRQ 6WHDP 6\\VWHP

,

0DLQ6WHDP&KDVH 9ROXPH 

,

7RUXV$UHD 9ROXPHVDQG 

,

5&,& 6WHDP 6\\VWHP

,

0DLQ6WHDP&KDVH 9ROXPH 

,

7RUXV$UHD 9ROXPH 

,

5&,&&RPSDUWPHQW 9ROXPH 

,

5HDFWRU:DWHU&OHDQ8S 5:&8 6\\VWHP

,

5:&8$UHD 9ROXPH 

,

0*6HW5RRP 9ROXPH 

,

5HDFWRU%XLOGLQJ)RRW(OHYDWLRQ1RUWKZHVW$UHD 9ROXPH 

,

5HDFWRU%XLOGLQJ2SHQ$UHD)RRW(OHYDWLRQ:HVW6LGH 9ROXPH 

,

0DLQ6WHDP&KDVH 9ROXPH 

,

&RUH6SUD\\6\\VWHP

,

5HVLGXDO+HDW5HPRYDO6\\VWHP

,

+3&, :DWHU 6\\VWHP

,

5&,& :DWHU 6\\VWHP

,

6WDQGE\\/LTXLG&RQWURO

,

2II*DV6\\VWHP

,

=LQF2[LGH,QMHFWLRQ6\\VWHP *(=,3 

,

7DEOHRI6\\VWHP(IIHFWV

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,

/RFDWLRQRI+LJK(QHUJ\\6\\VWHPVDQG6DIH6KXWGRZQ(TXLSPHQWE\\

9ROXPH

7DEOH,

7DEOHRI6\\VWHP(IIHFWV

,

5HIHUHQFHV

),*85(6



)LJXUH,

5HDFWRU%OGJ(O

#

)LJXUH,

5HDFWRU%OGJ $SSUR[

#

)LJXUH,

5HDFWRU%OGJ(O

#

)LJXUH,

5HDFWRU%OGJ(O#

)LJXUH,

5HDFWRU%OGJ

 ':9HVVHO #

)LJXUH,

5HDFWRU%OGJ

#

)LJXUH,

5HDFWRU%OGJ

#

)LJXUH,

7XUELQH%OGJ(O#

)LJXUH,

7XUELQH%OGJ(O

#

)LJXUH,

7XUELQH%OGJ(O#



0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

(YDOXDWLRQ&ULWHULD

5HJXODWRU\\$SSURYHG$QDO\\VHVRIWKH&RQVHTXHQFHVRI+LJK(QHUJ\\3LSLQJ)DLOXUH

2XWVLGH&RQWDLQPHQW/LFHQVLQJ%DVLV

6WDQGDUG5HYLHZ3ODQW5HIHUHQFH$WWDFKPHQW%UDQFK7HFKQLFDO3RVLWLRQ

$6%3URWHFWLRQ$JDLQVW3RVWXODWHG3LSLQJ)DLOXUHV,Q)OXLG6\\VWHPV2XWVLGH

&RQWDLQPHQW6HFWLRQ%G,PSOHPHQWDWLRQ'HVLJQVRISODQWVIRUZKLFKRSHUDWLQJ

OLFHQVHVDUHLVVXHGEHIRUH-XO\\DUHFRQVLGHUHGDFFHSWDEOHZLWKUHJDUGWRHIIHFWRI

SLSLQJIDLOXUHVRXWVLGHFRQWDLQPHQWRQWKHEDVLVRIWKHDQDO\\VHVPDGHDQGPHDVXUHVWDNHQ

E\\DSSOLFDQWVDQGOLFHQVHHVLQUHVSRQVHWRWKH'HFHPEHUOHWWHUIURP$*LDPEXVVR

DQGWKHVWDIIUHYLHZDQGDFFHSWDQFHRIWKHVHDQDO\\VHVDQGPHDVXUHV0RQWLFHOOR

RSHUDWLQJOLFHQVHZDVLVVXHGRQ-XQH

7KHUHIRUHWKHOLFHQVLQJEDVLVRIWKH0RQWLFHOOR1XFOHDU*HQHUDWLQJ3ODQW+(/%

3URJUDPLV

x

7KH*LDPEXVVROHWWHUGDWHG'HFHPEHUZLWK(UUDWDGDWHG-DQXDU\\

5HIHUHQFH

x

01*3DQDO\\VHVDQGPHDVXUHWDNHQLQUHVSRQVHWRWKH*LDPEXVVROHWWHUGDWHG

6HSWHPEHU5HIHUHQFH

x

$(&UHYLHZDQGDFFHSWDQFH6DIHW\\(YDOXDWLRQGDWHG-XO\\5HIHUHQFH

$QDGGLWLRQDO01*3+(/%/LFHQVH%DVHVLVWKHHOLPLQDWLRQRIUDQGRPEUHDNVDQGFUDFNV

LQGLFDWHGLQWKHDERYHOLFHQVHGRFXPHQWV5HYLVLRQWR0RQWLFHOOR/LFHQVH$PHQGPHQW

5HTXHVWIRU3RZHU5H5DWHOHWWHUGDWHG'HFHPEHU5HIHUHQFH([KLELW(

SDUDJUDSKVWDWHV6HYHUDOSUHYLRXVO\\SRVWXODWHGEUHDNORFDWLRQVZHUHHOLPLQDWHG

WKURXJKWKHDSSOLFDWLRQRIFULWHULDHVWDEOLVKHGLQ6WDQGDUG5HYLHZ3ODQDQG*HQHULF

/HWWHU([KLELW(3DUDJUDSKJLYHVWKHYHUVLRQRI*/XVHGDV-XQH

5HIHUHQFH7KLVYHUVLRQRI*/FRQWDLQHGWKHYHUVLRQRI%UDQFK7HFKQLFDO

3RVLWLRQ0(%RI653XVHG7KLV/$5SURYLVLRQZDVDSSURYHGE\\WKH15&LQ6(5

IRUSRZHUUHUDWH$PHQGPHQWGDWHG6HSWHPEHU5HIHUHQFH7KH6(5 V

DSSURYDOZDVE\\UHIHUHQFHWKH6(5 V5HIHUHQFH

'HVLJQ%DVH&RUUHVSRQGHQFHZLWK15&

,QDGGLWLRQWRWKHDQDO\\VLVWKDWVXSSRUWVWKH/LFHQVLQJ%DVHVWKHIROORZLQJVXEVHTXHQW

FRUUHVSRQGHQFHFRQFHUQLQJWKH/LFHQVLQJ%DVHVKDYHRFFXUUHGDQGVXSSRUWVWKH

DGHTXDF\\RIWKHSUHYLRXVGRFXPHQWHG/LFHQVLQJ%DVHVDGHTXDF\\ZKLFKJRYHUQVEXWGRHV

QRWFKDQJHWKH/LFHQVLQJ%DVHV7KLVFRUUHVSRQGHQFHLVFRQVLGHUHGSDUWRIWKH+(/%

'HVLJQ%DVHV

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7KH+(/%LVVXHZDVLQLWLDWHGE\\WKH*LDPEXVVROHWWHU 5HIHUHQFH ZLWKLWVHQFORVXUH

³*HQHUDO,QIRUPDWLRQ5HTXLUHGIRU&RQVLGHUDWLRQRIWKH(IIHFWVRID3LSLQJ6\\VWHP%UHDN

2XWVLGH&RQWDLQPHQW'7KHOHWWHULVD³UHTXHVW'RI1RUWKHUQ6WDWHV3RZHU 163 WRSURYLGH

³DQDO\\VHVDQGRWKHUUHOHYDQWLQIRUPDWLRQQHHGHGWRGHWHUPLQHWKHFRQVHTXHQFHVRIVXFK

DQHYHQWXVLQJWKHJXLGDQFHSURYLGHGLQWKHHQFORVHGJHQHUDOLQIRUPDWLRQUHTXHVW<<<RX

VKRXOGGHWHUPLQHWKHDSSOLFDELOLW\\IRUWKH0RQWLFHOORIDFLOLW\\RIWKHLWHPVOLVWHGLQWKH

HQFORVXUH'

7KH5HIHUHQFHHQFORVXUH¶VLQWURGXFWRU\\SDUDJUDSKVWDWHV³DSSOLFDQWVDQGOLFHQVHHV

VKRXOGGHWHUPLQHRQDQLQGLYLGXDOEDVLVWKHDSSOLFDELOLW\\RIHDFKRIWKHIROORZLQJLWHPVIRU

LQFOXVLRQLQWKHLUVXEPLWWDOV



7KHV\\VWHPV RUSRUWLRQVRIV\\VWHPV IRUZKLFKSURWHFWLRQDJDLQVWSLSHZKLSLV

UHTXLUHGVKRXOGEHLGHQWLILHG3URWHFWLRQIURPSLSHZKLSQHHGQRWEHSURYLGHGLIDQ\\RI

WKHIROORZLQJFRQGLWLRQVZLOOH[LVW

D 

%RWKRIWKHIROORZLQJSLSLQJV\\VWHPFRQGLWLRQVDUHPHW

 

WKHVHUYLFHWHPSHUDWXUHLVOHVVWKDQ)DQG

 

WKHGHVLJQSUHVVXUHLVSVLJRUOHVV'

7KHIRUPDO163UHVSRQVH 5HIHUHQFH WRWKH*LDPEXVVROHWWHUVXEPLWWHGWKH0RQWLFHOOR

+(/%DQDO\\VLVUHSRUW GDWHG$XJXVW 3RVWXODWHG3LSH)DLOXUHV2XWVLGH&RQWDLQPHQW

DVSDUWRIWKH0RQWLFHOOROLFHQVLQJEDVLV7KH0RQWLFHOOR$XJXVW+(/%UHSRUWWDNHV

H[FHSWLRQWRWKH*LDPEXVVROHWWHU¶V+(/%VHOHFWLRQFULWHULDDV6HFWLRQVSHFLILFDOO\\

VWDWHV

³7KHDQDO\\VLVKDVEHHQFRQGXFWHGXVLQJWKHIROORZLQJJHQHUDOSURFHGXUHV



7KHKLJKHQHUJ\\SLSLQJV\\VWHPVZHUHLGHQWLILHGXVLQJWKHFULWHULDWKDWWKHVHUYLFH

WHPSHUDWXUHLVJUHDWHUWKDQ)DQGWKHGHVLJQSUHVVXUHLVJUHDWHUWKDQ

SVLJ'

$IWHUWKH$(&UHYLHZVZHUHFRPSOHWHGWKH$(&WUDQVPLWWHGWKHLUIRUPDODSSURYDOZLWK

UHODWHG6DIHW\\(YDOXDWLRQ 6( RIWKH0RQWLFHOOR+(/%DQDO\\VLVLQ5HIHUHQFH

5HIHUHQFHVSHFLILFDOO\\DGGUHVVHVWKH$(&DFFHSWDQFHRI163¶VOHWWHUGDWHG

6HSWHPEHUDQGLWV³VXEPLWWHGUHSRUWRQ3RVWXODWHG3LSH)DLOXUHV2XWVLGH

&RQWDLQPHQWGDWHG$XJXVW'7KH$(&6(VWDWHV³3URWHFWLRQ<<VKRXOGEH

SURYLGHG<<IURPUXSWXUHVLQSLSHVFDUU\\LQJKLJKHQHUJ\\IOXLGZKHUHWKHWHPSHUDWXUHDQG

SUHVVXUHFRQGLWLRQVRIWKHIOXLGH[FHHG)DQGSVLJUHVSHFWLYHO\\'7KHDSSURYHG

RULJLQDOOLFHQVLQJEDVLVIRU0RQWLFHOOR¶V+(/%VHOHFWLRQFULWHULDDOORZVIRUDQH[FHSWLRQWR

WKHJXLGDQFHLQWKH*LDPEXVVROHWWHU

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7KH*LDPEXVVROHWWHUZDVZULWWHQWRKDYH163DGGUHVV&)5$SSHQGL[$*HQHUDO

'HVLJQ&ULWHULRQ(QYLURQPHQWDODQGG\\QDPLFHIIHFWVGHVLJQEDVHVZLWKUHVSHFWWR+(/%

RXWVLGHFRQWDLQPHQW0RQWLFHOORZDVGHVLJQHGDQGEXLOWEHIRUHWKH*HQHUDO'HVLJQ&ULWHULD

*'& ZHUHLVVXHG7KHUHIRUH0RQWLFHOORZDVQRWGHVLJQHGDVD*'&FRPSOLDQWSODQW

15&1552IILFH,QVWUXFWLRQ/,&&RQWURORI/LFHQVLQJ%DVHVIRU2SHUDWLQJ5HDFWRUV

5HIHUHQFH SURYLGHVJXLGDQFHRQKRZWRLQWHUSUHWWKHOLFHQVLQJEDVHVRIROGHUSODQWV

OLNH0RQWLFHOORZLWKUHVSHFWWRPHHWLQJWKH*'&/,&6XEVHFWLRQ$SSHQGL[$

³*HQHUDO'HVLJQ&ULWHULD'VWDWHV

³7KH*HQHUDO'HVLJQ&ULWHULDDUHQRWDSSOLFDEOHWRSODQWVZLWKFRQVWUXFWLRQSHUPLWV

LVVXHGSULRUWR0D\\$WWKHWLPHRIWKHSURPXOJDWLRQRI$SSHQGL[$WKH

&RPPLVVLRQVWUHVVHGWKDWWKH*'&ZHUHQRWQHZUHTXLUHPHQWVDQGZHUHSURPXOJDWHG

WRPRUHFOHDUO\\DUWLFXODWHWKHOLFHQVLQJUHTXLUHPHQWVDQGSUDFWLFHLQHIIHFWDWWKDWWLPH

KLOHFRPSOLDQFHZLWKWKHLQWHQWRIWKH*'&LVLPSRUWDQWHDFKSODQWOLFHQVHGEHIRUHWKH
  • '&ZHUHIRUPDOO\\DGRSWHGZDVHYDOXDWHGRQDSODQWVSHFLILFEDVHVGHWHUPLQHGWREH

VDIHDQGOLFHQVHGE\\WKH&RPPLVVLRQ)XUWKHUPRUHFXUUHQWUHJXODWRU\\SURFHVVHVDUH

VXIILFLHQWWRHQVXUHWKDWSODQWVFRQWLQXHWREHVDIHDQGFRPSO\\ZLWKWKHLQWHQWRIWKH

  • '&'

7KH15&6(DFFHSWDQFHOHWWHU 5HIHUHQFH VWDWHPHQW³%DVHGRQRXUUHYLHZRIWKH

LQIRUPDWLRQ\\RXKDYHVXEPLWWHGRQWKH0RQWLFHOOR1XFOHDU*HQHUDWLQJ3ODQWZHKDYH

GHWHUPLQHGWKDWDIWHUFRPSOHWLRQRIWKHSURSRVHGPRGLILFDWLRQVWKHSODQWZRXOGZLWKVWDQG

WKHFRQVHTXHQFHVRISRVWXODWHGUXSWXUHVLQKLJKHQHUJ\\IOXLGSLSLQJRXWVLGHWKH

FRQWDLQPHQWZLWKRXWORVVRIWKHFDSDELOLW\\WRLQLWLDWHDQGPDLQWDLQWKHSODQWLQDVDIH

VKXWGRZQFRQGLWLRQ'GHPRQVWUDWHVWKDW0RQWLFHOORFRPSOLHGZLWKWKHLQWHQWRI*'&

7KHFXUUHQWOLFHQVLQJEDVLV &/% UHTXLUHPHQWLVIRU0RQWLFHOORWRFRPSO\\ZLWKWKHLQWHQWRI

  • '&DVGHVFULEHGLQWKH+(/%DQDO\\VLV

5HIHUHQFHUHSRUWHGWKHGLVFRYHU\\RIDQDSSOLFDEOHDUHDRIWKHWXUELQHEXLOGLQJWKDWPD\\

KDYHQRWEHHQLQFOXGHGLQWKH+(/%DQDO\\VLV$VSDUWRIUHVROXWLRQRIWKDWGLVFRYHUHG

FRQGLWLRQ163WKRURXJKO\\UHYLHZHGWKHRULJLQDODQDO\\VLV7KHUHVXOWVRIWKDWDQDO\\VLV

DUHGRFXPHQWHGLQWKH5HIHUHQFH187(&+(QJLQHHULQJUHSRUWDQGWKDWUHSRUWZDV

VXEPLWWHGWRWKH15&LQWKH5HIHUHQFH

6HFWLRQRIWKH187(&+UHSRUWGHILQHVWKHHYDOXDWLRQDSSURDFKDQGKRZWKH6WDQGDUG

5HYLHZ3ODQ 653 DQG$16,$16ZHUHXVHGWRFODULI\\DQDO\\WLFDODVVXPSWLRQV

7KHVHKHOSHGWREHWWHUGHILQHWKHDVVXPSWLRQVIRURSHUDWLQJFRQGLWLRQVDYDLODELOLW\\RI

RIIVLWHSRZHUFRQVLGHUDWLRQRIVLPXOWDQHRXVHYHQWVVLQJOHDFWLYHIDLOXUHEUHDNORFDWLRQV

SLSHZKLSHIIHFWVMHWLPSLQJHPHQWHIIHFWVDQGIORRGLQJHIIHFWV

5HTXHVWIRU$GGLWLRQDO,QIRUPDWLRQ 5$, IURP5HIHUHQFHUHIHUVWRWKH+(/%VHOHFWLRQ

FULWHULDLQ6HFWLRQRIWKH187(&+UHSRUWDQGVWDWHV³7KHVHOHFWLRQFULWHULDDUHOHVV

FRQVHUYDWLYHWKDQWKH*LDPEXVVRFULWHULD VHUYLFHZDWHUWHPSHUDWXUHH[FHHGV)RU

GHVLJQSUHVVXUHH[FHHGVSVLJ DVZHOODVWKH653FULWHULD PD[LPXPRSHUDWLQJ

WHPSHUDWXUHH[FHHGV)DQGPD[LPXPRSHUDWLQJSUHVVXUHH[FHHGVSVLJ -XVWLI\\

WKHGHYLDWLRQDQGSURYLGHDOLVWRIWKHSLSLQJV\\VWHPVWKDWZRXOGEHLQFOXGHGLQWKH

0RQWLFHOOR+(/%DQDO\\VLVLIWKH*LDPEXVVRFULWHULDZHUHXVHGDQGDOLVWLIWKH653

FULWHULDZHUHXVHG'

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





5HIHUHQFHVXEPLWWHGWKHILQDO163UHVSRQVHWRWKH+(/%VHOHFWLRQFULWHULDLVVXHLQ

5$,7KHUHVSRQVHVWDWHV

µ:LWKRQHH[FHSWLRQWKHFULWHULDXVHGIRUWKHVHOHFWLRQRIKLJKHQHUJ\\OLQHVZDV

³RSHUDWLQJWHPSHUDWXUHJUHDWHUWKDQ)DQGGHVLJQSUHVVXUHJUHDWHUWKDQSVLJ'

7KLVFULWHULDLVFRQVLVWHQWZLWKWKHFULWHULDXVHGLQWKHRULJLQDO0RQWLFHOOR+LJK

(QHUJ\\/LQH%UHDNDQDO\\VLV6HFWLRQ,RI$SSHQGL[,ZLOOEHUHYLVHGWRUHIOHFWWKLV

VHOHFWLRQFULWHULDDVSDUWRIWKHQH[WDQQXDOXSGDWHWRWKH0RQWLFHOOR86$5¶

86$5$SSHQGL[,KDVEHHQXSGDWHGWRVSHFLILFDOO\\LQFOXGHWKH+(/%VHOHFWLRQFULWHULD

FRQVLVWHQWZLWKWKHFULWHULDXVHGLQDQGDQDO\\VHV 

$OWKRXJKWKH15&GLGQRWLVVXHDIRUPDO6(WKH15& LQ5HIHUHQFH GRHVDFNQRZOHGJH

³$GGLWLRQDOLQIRUPDWLRQZDVSURYLGHG-XQH'HFHPEHU6HSWHPEHU

'HFHPEHU 5HIHUHQFHKHUHLQ -DQXDU\\DQG)HEUXDU\\

'5HIHUHQFHFRQFOXGHVWKDWWKH³RULJLQDOQRQFRQIRUPLQJ+(/%FRQGLWLRQVKDYH

EHHQFRUUHFWHG'

)XUWKHUUHYLHZRIWKH+(/%FULWHULDRFFXUUHGZLWKDQH[WHQGHGSRZHUXSUDWH (38 5$,

UHVSRQVH 5HIHUHQFH ZLWK15&UHYLHZGRFXPHQWHGLQ5HIHUHQFH

,

'HILQLWLRQRI7HUPV

&LUFXPIHUHQWLDO%UHDN$SLSHEUHDNSHUSHQGLFXODUWRWKHSLSHD[LVZLWKDEUHDNDUHD

HTXLYDOHQWWRWKHLQWHUQDOFURVVVHFWLRQDODUHDRIWKHUXSWXUHGSLSH

&RPSDUWPHQW7KHFROOHFWLYHWHUPXVHGWRGHVFULEHURRPVED\\VKDOOZD\\VHWFWKDW

PDNHXSDQHQFORVXUHLQZKLFKDKLJKHQHUJ\\SLSHLVURXWHGRUSLSHEUHDNPD\\WDNH

SODFH

&RPSDUWPHQWDO3UHVVXUL]DWLRQ7KHFRQGLWLRQRISUHVVXUL]DWLRQRIDFRPSDUWPHQW

DERYHLWVQRUPDOSUHVVXUHGXHWRDKLJKHQHUJ\\OLQHEUHDNZLWKLQWKHFRPSDUWPHQW

&ULWLFDO&UDFN7KHVLQJOHSRVWXODWHGFUDFNRQDKLJKHQHUJ\\OLQHWKDWSURGXFHVWKH

PRVWDGYHUVHHIIHFWRQVDIHVKXWGRZQHTXLSPHQWZLWKLQDFRPSDUWPHQW'LPHQVLRQDOO\\

WKHFULWLFDOFUDFNVL]HLVSRVWXODWHGWREHRQHKDOIWKHSLSHLQVLGHGLDPHWHULQOHQJWKE\\

RQHKDOIWKHSLSHWKLFNQHVVLQZLGWK

(TXLSPHQW4XDOLILFDWLRQ7KHWHUPXVHGWRGHVFULEHWKHDELOLW\\RIHTXLSPHQWWRUHPDLQ

IXQFWLRQDOLQWKHDEQRUPDOWHPSHUDWXUHSUHVVXUHKXPLGLW\\DQGUDGLDWLRQHQYLURQPHQWV

JHQHUDWHGE\\DSRVWXODWHG+(/%ZLWKLQDFRPSDUWPHQW

)ORRGLQJ7KHFRQGLWLRQHQFRXQWHUHGZLWKLQDFRPSDUWPHQWRUDGMRLQLQJFRPSDUWPHQWV

ZKHQOLTXLGZDWHURUFRQGHQVLQJVWHDPHVFDSHVIURPDUXSWXUHGKLJKHQHUJ\\OLQHRU

RWKHUFRPSRQHQWDWDIDVWHUUDWHWKDQWKHIOXLGFDQEHGUDLQHGDZD\\

+LJK(QHUJ\\)OXLG$IOXLGZLWKDQRUPDORSHUDWLQJSUHVVXUHJUHDWHUWKDQSVLJDQG

DQRUPDORSHUDWLQJWHPSHUDWXUHJUHDWHUWKDQ) 5HIHUHQFHDQG 

+LJK(QHUJ\\6\\VWHP$Q\\PHFKDQLFDOV\\VWHPZLWKSLSLQJFRQWDLQLQJKLJKHQHUJ\\IOXLG

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





+LJK(QHUJ\\/LQH$Q\\SLSHZKLFKFDUULHVIOXLGZLWKDQRUPDORSHUDWLQJSUHVVXUH

JUHDWHUWKDQSVLJDQGDQRUPDORSHUDWLQJWHPSHUDWXUHJUHDWHUWKDQ)

5HIHUHQFHDQG 

-HW,PSLQJHPHQW7KHIRUFHVH[HUWHGRQWDUJHWVE\\KLJKSUHVVXUHIOXLGH[LWLQJDEUHDN

LQWKHSLSH

/RQJLWXGLQDO%UHDN$SLSHEUHDNSDUDOOHOWRWKHSLSHD[LVDQGRULHQWHGDWDQ\\SRLQW

DURXQGWKHSLSHFLUFXPIHUHQFHZLWKDEUHDNDUHDHTXDOWRWKHHIIHFWLYHFURVVVHFWLRQDO

IORZDUHDLPPHGLDWHO\\XSVWUHDPRIWKHEUHDNORFDWLRQ

1RUPDO2SHUDWLQJ&RQGLWLRQV1RUPDOVWHDG\\VWDWHRSHUDWLQJFRQGLWLRQVRIUDWHG

SRZHU

3LSH:KLS7KHPHFKDQLFDOUHDFWLRQFDXVHGE\\KLJKHQHUJ\\IOXLGH[LWLQJDUXSWXUHG

SLSH

5HDFWRU3ODQW3URWHFWLYH$FWXDWLRQ$+(/%WKDWFDXVHVD7HFKQLFDO6SHFLILFDWLRQ

VSHFLILHGWULS)RU+(/%WKLVLVD&RQWDLQPHQW*URXS,VRODWLRQDQGRUVFUDP

5HIHUHQFH(UUDWD 

6DIH6KXWGRZQ6KXWGRZQRIWKHXQLWIURPSRZHUWRVXEFULWLFDOFRQGLWLRQZLWK

WHPSHUDWXUHLQWKHUHDFWRURIOHVVWKDQRUHTXDOWR)QRUHVXOWLQJIXHOGDPDJHDQG

QRVWUXFWXUDOIDLOXUHRISULPDU\\RUVHFRQGDU\\FRQWDLQPHQW

6DIH6KXWGRZQ6\\VWHP&RPSRQHQW6\\VWHPVDQGFRPSRQHQWVUHTXLUHGWRVDIHO\\

VKXWGRZQWKHUHDFWRUDQGPLWLJDWHWKHFRQVHTXHQFHVRIDKLJKHQHUJ\\OLQHEUHDNZLWKRXW

RIIVLWHSRZHU

6LQJOH$FWLYH)DLOXUH7KHPDOIXQFWLRQRUORVVRIIXQFWLRQRIDQHOHFWULFDORUIOXLG

V\\VWHPFRPSRQHQWH[FOXGLQJSDVVLYHIDLOXUHVZKLFKUHO\\RQPHFKDQLFDOPRYHPHQWWR

FRPSOHWHLWVLQWHQGHGIXQFWLRQXSRQGHPDQG

7HUPLQDO(QG([WUHPLWLHVRISLSLQJUXQVWKDWFRQQHFWWRVWUXFWXUHVFRPSRQHQWV HJ

YHVVHOVSXPSVYDOYHV RUSLSHDQFKRUVWKDWDFWDVULJLGFRQVWUDLQWVWRSLSLQJPRWLRQ

DQGWKHUPDOH[SDQVLRQ$EUDQFKFRQQHFWLRQWRDPDLQSLSLQJUXQLVDWHUPLQDOHQGRIWKH

EUDQFKUXQH[FHSWZKHUHWKHEUDQFKUXQLVFODVVLILHGDVSDUWRIDPDLQUXQLQWKHVWUHVV

DQDO\\VLVDQGLVVKRZQWRKDYHDVLJQLILFDQWHIIHFWRQWKHPDLQUXQEHKDYLRU,QSLSLQJ

UXQVZKLFKDUHPDLQWDLQHGSUHVVXUL]HGGXULQJQRUPDOSODQWFRQGLWLRQVIRURQO\\DSRUWLRQ

RIWKHUXQ LHXSWRWKHILUVWQRUPDOO\\FORVHGYDOYH DWHUPLQDOHQGRIVXFKUXQVLVWKH

SLSLQJFRQQHFWLRQWRWKLVFORVHGYDOYH 0(%)RRWQRWH+/-5HIHUHQFH $QRUPDOO\\

FORVHGYDOYHLVQRWFRQVLGHUHGDWHUPLQDOHQGLIWKHYDOYHLVSDUWRIWKHSLSHVWUHVV

DQDO\\VLV ZKLFKLQFOXGHVVHLVPLF DQGWKHYDOYHLVQRWVXSSRUWHGDVDQDQFKRU

5HIHUHQFH 

9ROXPHV7KHVXEGLYLVLRQRIWKHSODQW¶VEXLOGLQJVFKRVHQWRSURYLGHFRQVLVWHQW

LGHQWLILFDWLRQRIWKHFRPSDUWPHQWVHYDOXDWHGLQWKLVUHSRUW$VLPLODUEXWVHSDUDWHVHWRI

YROXPHQXPEHUVLVXVHGIRUWKH5HDFWRU%XLOGLQJDQG7XUELQH%XLOGLQJ6HH)LJXUH,

WKURXJK)LJXUH,



0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

$VVXPSWLRQV

7KHIROORZLQJDVVXPSWLRQVZHUHXVHGGXULQJWKH+(/%HYDOXDWLRQLQDFFRUGDQFHZLWK

WKHHYDOXDWLRQFULWHULDDERYH

,

$SRVWXODWHGEUHDNLVDVVXPHGWRRFFXUGXULQJ1RUPDO2SHUDWLQJ&RQGLWLRQV

,

,I5HDFWRU3ODQW3URWHFWLYH$FWXDWLRQKDVRFFXUUHGWKHQXQWLOLQLWLDOYHVVHOOHYHOKDV

VWDELOL]HGZKLFKHVWDEOLVKHVDGHTXDWHFRUHFRROLQJORVVRIRIIVLWHSRZHUFRQFXUUHQW

ZLWKWKHOLQHEUHDNLVDVVXPHG$IWHUZDUGVRIIVLWHSRZHULVDVVXPHGDQGVKXWGRZQ

LVDVGLUHFWHGE\\&(PHUJHQF\\2SHUDWLQJ3URFHGXUHV

,

1RILUHVRURWKHUVLPXOWDQHRXVOLQHEUHDNVRUDFFLGHQWVZHUHFRQVLGHUHG

,

,I5HDFWRU3ODQW3URWHFWLRQ$FWXDWLRQKDVRFFXUUHGWKHQXQWLOLQLWLDOYHVVHOOHYHOKDV

VWDELOL]HGZKLFKHVWDEOLVKHVDGHTXDWHFRUHFRROLQJDVLQJOHDFWLYHFRPSRQHQW

IDLOXUHZDVDVVXPHG$IWHUZDUGVVLQJOHDFWLYHIDLOXUHLVQRWDVVXPHGDQGVKXWGRZQ

LVDVGLUHFWHGE\\&(PHUJHQF\\2SHUDWLQJ3URFHGXUHV

,

&LUFXPIHUHQWLDOEUHDNVZHUHDVVXPHGWRUHVXOWLQFRPSOHWHSLSHVHYHUDQFHZLWKIXOO

VHSDUDWLRQRIWKHWZRVHYHUHGSLSHHQGV LHJXLOORWLQH 7KHEUHDNZDVDVVXPHGWR

EHSHUSHQGLFXODUWRWKHORQJLWXGLQDOD[LVRIWKHSLSH&LUFXPIHUHQWLDOEUHDNV

SRVWXODWHGDWILWWLQJVZHUHDVVXPHGWREHDWWKHILWWLQJWRSLSHZHOG V 

,

/RQJLWXGLQDOEUHDNVZHUHDVVXPHGWREHRULHQWHGSDUDOOHOWRWKHORQJLWXGLQDOD[LVRI

WKHSLSHRULHQWHGDWDQ\\SRLQWDURXQGWKHSLSHFLUFXPIHUHQFHZLWKDEUHDNDUHDHTXDO

WRWKHHIIHFWLYHFURVVVHFWLRQDOIORZDUHDLPPHGLDWHO\\XSVWUHDPRIWKHEUHDNORFDWLRQ

/RQJLWXGLQDOEUHDNVSRVWXODWHGDWILWWLQJVZHUHDVVXPHGWREHDWWKHFHQWHURIWKH

ILWWLQJ

,

&ODVV,6\\VWHPVIRUZKLFKVWUHVVGDWDZDVQRWDYDLODEOHWRGHWHUPLQHEUHDN

ORFDWLRQVZHUHWUHDWHGDV&ODVV,,6\\VWHPV

,

$QRUPDOO\\FORVHGFKHFNYDOYHLQDSLSLQJOLQHXWLOL]HGDVDQLQERDUGFRQWDLQPHQW

LVRODWLRQYDOYHZDVDVVXPHGWROHDN7KHOHDNDJHZDVDVVXPHGWRUHVXOWLQ

SUHVVXUL]DWLRQRIWKDWVHFWLRQRISLSHRXWWRWKHILUVWQRUPDOO\\FORVHGYDOYHRXWVLGHWKH

3ULPDU\\&RQWDLQPHQW

,

$QRUPDOO\\FORVHGFKHFNYDOYHZDVDVVXPHGWRUHPDLQFORVHGLQWKHHYHQWRID

SRVWXODWHGOLQHEUHDNEHWZHHQWKHFKHFNYDOYHDQGWKHILUVWQRUPDOO\\FORVHGYDOYH

RXWVLGHWKHSULPDU\\FRQWDLQPHQW)RUWKLVFRQGLWLRQWKHFKHFNYDOYHZDVDVVXPHGWR

EHDSDVVLYHFRPSRQHQW

,

%UHDNVGRQRWQHHGWREHSRVWXODWHGLQVHFWLRQVRISLSLQJIURPFRQWDLQPHQWXSWRWKH

RXWERDUGLVRODWLRQYDOYHSURYLGHGWKDWWKHUHTXLUHPHQWVRI%UDQFK7HFKQLFDO3RVLWLRQ

0(%DVLGHQWLILHGLQ6WDQGDUG5HYLHZ3ODQ185(*KDYHEHHQPHW

,

%UHDNORFDWLRQVZHUHSRVWXODWHGIRUDOOKLJKHQHUJ\\SLSLQJZLWKDQRPLQDOGLDPHWHU

JUHDWHUWKDQLQFKDQGDQRUPDORSHUDWLRQWLPHH[FHHGLQJIRUWKHWRWDOXQLW

RSHUDWLRQWLPH 5HIHUHQFH 

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,

9ROXPH'HVFULSWLRQVIRU+(/%VLQWKH5HDFWRU%XLOGLQJ



92/80(

92/80('(6&5,37,21



5+5DQG&RUH6SUD\\3XPS5RRP'LYLVLRQ,



5+5DQG&RUH6SUD\\3XPS5RRP'LYLVLRQ,6WDLUZD\\



5+5DQG&RUH6SUD\\3XPS5RRP'LYLVLRQ,,



5+5DQG&RUH6SUD\\3XPS5RRP'LYLVLRQ,,6WDLUZD\\



5&,&5RRP



5HDFWRU%OGJ(OHYDWLRQ(TXLSPHQWDQG)ORRU'UDLQ7DQN



&5'3XPS5RRP



+3&,5RRP



6XSSUHVVLRQ3RRO$UHD1RUWKHDVW



6XSSUHVVLRQ3RRO$UHD6RXWKHDVW



6XSSUHVVLRQ3RRO$UHD6RXWKZHVW



6XSSUHVVLRQ3RRO$UHD1RUWKZHVW



(DVW6KXWGRZQ&RROLQJ5RRP



&5'+\\GUDXOLF&RQWURO8QLW$UHD(DVW(OHYDWLRQ



7,35RRP



6WHDP&KDVH



7,3'ULYH5RRP



&5'+\\GUDXOLF&RQWURO8QLW$UHDDQG+9$&$UHDV1:(O



&5'+\\GUDXOLF&RQWURO8QLW$UHDDQG+9$&$UHDV6:(O



HVW6KXWGRZQ&RROLQJ5RRP



3,3(&KDVH



0&&DQG6WDQGE\\/LTXLG&RQWURO6\\VWHP$UHD(DVW(O



&RQWDPLQDWHG7RRO6WRUDJH(DVW(O



5HFLUF0*6HW$LUORFN



1RUWKRI5HDFWRU6KLHOG:DOO



5HDFWRU5HFLUFXODWLRQ3XPSV0*6HW5RRP



&RROLQJ:DWHU3XPSDQG&KLOOHU$UHD:HVW(O



5:&83XPS5RRP%DQG+DOOZD\\



5:&83XPS5RRP$



5:&8+HDW([FKDQJHU$UHD



5:&8$UHD%HKLQG+[([FKDQJHU



5:&8,VRODWLRQ9DOYH5RRP



0&&DQG,QVWUXPHQW5DFN&$UHD



&*&6$5HFRPELQHU$UHD



&RROLQJ:DWHU+HDW([FKDQJHUDQG&*&6%5HFRPELQHU$UHD



6WDQGE\\*DV7UHDWPHQW6\\VWHP%7UDLQ5RRP



6WDQGE\\*DV7UHDWPHQW6\\VWHP)DQ5RRP



6WDQGE\\*DV7UHDWPHQW6\\VWHP$LUORFN



6WDQGE\\*DV7UHDWPHQW6\\VWHP$7UDLQ$UHD



5HDFWRU3OHQXP5RRP



5HDFWRU5HFLUFXODWLRQ0*6HW)DQ5RRP



&RUULGRU2XWVLGH0DLQ([KDXVW3OHQXP



6NLPPHU6XUJH7DQNDQG)XHO3RRO3XPSV$UHD



6QXEEHU5HEXLOGDQG'HFRQWDPLQDWLRQ$UHD



1RUWKHDVW6WDLUZD\\(O



&RQWDPLQDWHG(TXLSPHQW6WRUDJH$UHD



1RUWKZHVW6WDLUZD\\(O



5HIXHOLQJ)ORRU(O



0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,

9ROXPH'HVFULSWLRQVIRU+(/%VLQWKH7XUELQH%XLOGLQJ



92/80(

92/80('(6&5,37,21



0RWRU&RQWURO&HQWHU%$ %DQG%



7XUELQH%XLOGLQJVRXWKHDVW&RUQHUQHDU0&&%



/XEH2LO5HVHUYRLUDQG5HDFWRU)HHG3XPS$UHD



/XEH2LO6WRUDJH7DQN5RRP



7XUELQH%XLOGLQJ&RUULGRU1RUWKHDVW(O



DWHU%R[6FDYDJLQJ6\\VWHP$UHD



7XUELQH%XLOGLQJ6XPSDQG0&&%$UHD



.9DQG/RDG&HQWHU'LYLVLRQ$



+DOOZD\\RXWVLGH$LU(MHFWRU5RRP(QWUDQFH'RRU



+\\GURJHQ6HDO2LO8QLWDQG&RQGHQVDWH3XPS$UHD1RUWK



+\\GURJHQ6HDO2LO8QLWDQG&RQGHQVDWH3XPS$UHD6RXWK



0HFKDQLFDO9DFXXP3XPS$UHD



&RQGHQVDWH%DFNZDVK5HFHLYLQJ7DQN$UHD



$LU(MHFWRU5RRP



7XUELQH%DVHPHQW&RQGHQVHU$UHD



3LSH7XQQHOWR,QWDNH



,QWDNH(QWU\\$UHD



,QWDNH6WUXFWXUH3XPS5RRP



&LUF:DWHU3XPS$UHD



7XUELQH%XLOGLQJ(O(DVW



7XUELQH%XLOGLQJ(O9HQW&KDVH



7XUELQH%XLOGLQJ&RUULGRU1RUWKZHVWDQG+DOOZD\\WR1R'*

(QWU\\(O



7XUELQH%XLOGLQJ1RUWKZHVW6WDLUZD\\IURPWR(O



9DOYH2SHUDWLQJ*DOOHU\\DQG&RQGHQVDWH'HPLQ3DQHOV$UHD



):3LSHDQG&DEOH7UD\\3HQHWUDWLRQ5RRP



$X[LOLDU\\%RLOHU5RRP



(DVW(OHFWULFDO(TXLSPHQW5RRPDQG('*



N96ZLWFKJHDU5RRPV



7XUELQH%XLOGLQJ&RUULGRU6RXWKHDVW&RUQHU(O



&DEOH&KDVH(O



1R'LHVHO*HQHUDWRU5RRP



1R'LHVHO*HQHUDWRU5RRP(QWU\\$UHD



1R'LHVHO*HQHUDWRU5RRP



6WDWRU:DWHU&RROLQJ$UHD



.9DQG/RDG&HQWHU'LYLVLRQ%



5HDFWRU%XLOGLQJ3OHQXP5RRP



7XUELQH%XLOGLQJ5DLOURDG&DU6KHOWHU



5HDFWRU%XLOGLQJ6WHDP&KDVH



7XUELQH'HFNWR(O



0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

+LJK(QHUJ\\6\\VWHPVDQG3LSLQJ

+LJKHQHUJ\\SLSLQJZDVDVVXPHGWREHDOOSLSLQJZLWKDQRUPDORSHUDWLQJWHPSHUDWXUH

H[FHHGLQJ)DQGDGHVLJQSUHVVXUHH[FHHGLQJSVLJ 5HIHUHQFHDQG ,IWKH

DFWXDORSHUDWLQJWHPSHUDWXUHZDVQRWNQRZQWKHGHVLJQWHPSHUDWXUHZDVFRQVHUYDWLYHO\\

VXEVWLWXWHG$OOV\\VWHPVKDYLQJSLSLQJFRQWDLQLQJKLJKHQHUJ\\IOXLGVDUHFODVVLILHGDVKLJK

HQHUJ\\V\\VWHPVDQGWKRVHSRUWLRQVRIWKHSLSLQJFRQWDLQLQJWKHKLJKHQHUJ\\IOXLGDUH

LGHQWLILHGDVKLJKHQHUJ\\OLQHV

D

0DLQ6WHDP

E

)HHGZDWHU

F

&RQGHQVDWH

G

+3&, VWHDP 

H

5&,& VWHDP 

I

5:&8 5HDFWRU:DWHU&OHDQXS 

J

,QVWUXPHQWDQGVDPSOHOLQHV LGHQWLILHGZLWKDVVRFLDWHGV\\VWHPVLQ7DEOH, 

K

&RUH6SUD\\

L

5HVLGXDO+HDW5HPRYDO

M

+3&, LQMHFWLRQ 

N

5&,& LQMHFWLRQ 

O

6WDQGE\\/LTXLG&RQWURO

P

2IIJDV

Q

&RQWURO5RG'ULYH

R

  • (=,3 =LQF2[LGH,QMHFWLRQ 

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

+LJK(QHUJ\\/LQHDQG6\\VWHP'HVFULSWLRQV

7KHSULPDU\\KLJKHQHUJ\\OLQHVDUHGHVFULEHGE\\V\\VWHPLQWKHIROORZLQJSDUDJUDSKV

7KHVHGHVFULSWLRQVLGHQWLI\\WKHSLSLQJFRQWDLQLQJWKHKLJKHQHUJ\\IOXLGVWKH

FRPSDUWPHQWVFRQWDLQLQJWKHKLJKHQHUJ\\OLQHVWKHERXQGDULHVRIWKHKLJKHQHUJ\\

SRUWLRQVRIWKHSLSLQJDQGWKHMXVWLILFDWLRQVIRUH[FOXGLQJDQ\\RIWKHSLSLQJIURPIXUWKHU

+(/%FRQVLGHUDWLRQ

)RUFRQYHQLHQFHWKHLGHQWLILFDWLRQRIVSHFLILFSODQWDUHDVFRPSDUWPHQWVDQGURRPV

ZDVDFFRPSOLVKHGE\\VXEGLYLGLQJWKHPDMRUEXLOGLQJVRIWKHSODQWLQWRGLVFUHWHYROXPHV

IRUXVHLQWKH+(/%DQDO\\VLV$OLVWRIYROXPHVLVSURYLGHGLQ7DEOHV,DQG,

,

0DLQ6WHDP6\\VWHP

7KHKLJKHQHUJ\\OLQHVIRUWKH0DLQ6WHDP6\\VWHPDUHORFDWHGLQFRPSDUWPHQWVWKH

PDLQVWHDPFKDVH 9ROXPH LQWKH5HDFWRU%XLOGLQJWKHFRQGHQVHUDUHD

9ROXPH WKHVWHDPMHWDLUHMHFWRU 6-$( URRP 9ROXPH DQGWKHWXUELQH

RSHUDWLRQIORRU 9ROXPH LQWKH7XUELQH%XLOGLQJ

7KHKLJKHQHUJ\\OLQHVRQWKH0DLQ6WHDP6\\VWHPLQFOXGHWKHIRXUPDLQVWHDPOLQHV

WKHHTXDOL]DWLRQOLQHVWKHWXUELQHE\\SDVVOLQHVWRWKHFRQGHQVHU0DLQ6WHDPWR6-$(

OLQHPDLQVWHDPWRVWHDPVHDOV\\VWHPDQGWKHPDLQVWHDPGUDLQOLQHV

7KHPDLQVWHDPOLQHERXQGDU\\SRLQWVDUHFRQWDLQPHQWSHQHWUDWLRQV;$;%;&

DQG;'DQGWKHIRXUQR))OHVWRWKHKLJKSUHVVXUHWXUELQH3LSLQJEHWZHHQWKH

FRQWDLQPHQWSHQHWUDWLRQVDQGWKHPDLQVWHDPRXWERDUGLVRODWLRQYDOYHVKDVEHHQ

HYDOXDWHGSHUWKHFULWHULDGHILQHGLQ,  E 7KHUHDUHDOVRWHUPLQDOSRLQWVDWWKH

LQOHWDQGRXWOHWWRWKHWXUELQHVWRSDQGFRQWUROYDOYHVIRUWKHIRXUPDLQVWHDPOLQHV

7KHHTXDOL]DWLRQOLQHVDUHFRQVLGHUHGEUDQFKOLQHVIURPWKHIRXUPDLQVWHDPOLQHV

7KHUHIRUHWKHLUERXQGDULHVDUHDWWKHWHHVWRWKHPDLQVWHDPOLQHV7KHWXUELQH

E\\SDVVOLQHERXQGDULHVDUHDWWKHWHHVLQWRWKHPDLQVWHDPOLQHVWKHSHQHWUDWLRQVDW

WKHFRQGHQVHUDQGWHUPLQDOSRLQWVDWWKHE\\SDVVFRQWUROYDOYHV7KHPDLQVWHDPWR

WKH6-$(¶VOLQHKDVERXQGDULHVDWWKHWHHVWRWKHPDLQVWHDPOLQHVDQGDWWKH6-$(

SUHVVXUHUHGXFLQJVWDWLRQLQWKH6-$(URRP7KHVWHDPVHDOUHJXODWRUOLQHVKDYH

ERXQGDULHVRQWKHVWHDPE\\SDVVOLQHDQGVWHDPVHDOUHJXODWRU7KHPDLQVWHDPGUDLQ

OLQHVKDYHERXQGDULHVDWWKHRXWERDUG3ULPDU\\&RQWDLQPHQWLVRODWLRQYDOYH

02DQGDWWKHLQFKUHGXFHUMXVWGRZQVWUHDPRIYDOYH02

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

)HHGZDWHU6\\VWHP

7KHKLJKHQHUJ\\)HHGZDWHU6\\VWHPSLSLQJ ):$('DQG):%(' EHJLQ

LQWKHIHHGZDWHUSXPSDUHD 9ROXPH DWWKHGLVFKDUJHQR))OHVRIIHHGSXPSV3$

DQG3%7KHWZRPDLQIHHGZDWHUOLQHV):$DQG):%SDVVWKURXJK

VRXWKHDVWFRUQHURIWKH7XUELQH%XLOGLQJ 9ROXPH XSLQWRWKH7XUELQH%XLOGLQJSLSH

FKDVHDUHD 9ROXPH DQGWKHQLQWRWKHFRQGHQVHUDUHD 9ROXPH %HIRUH

HQWHULQJWKH5HDFWRU%XLOGLQJVWHDPFKDVH 9ROXPH DQGWHUPLQDWLQJDW

FRQWDLQPHQWSHQHWUDWLRQV;$DQG;%HDFKIHHGZDWHUOLQHLVFRQQHFWHGWRWKH

UHVSHFWLYHKLJKSUHVVXUHIHHGZDWHUKHDWHUV ($ %DQG($ % RQWKH

WXUELQHRSHUDWLQJIORRU 9ROXPH 3LSLQJEHWZHHQWKHFRQWDLQPHQWSHQHWUDWLRQV

DQGWKHSULPDU\\FRQWDLQPHQWLVRODWLRQYDOYHV):DQG):KDVEHHQ

HYDOXDWHGSHUWKHFULWHULDGHILQHGLQ,  E 7KHIHHGZDWHUUHJXODWLQJVWDWLRQ

SLSLQJ):'(DQG):'(LVWHUPLQDWHGDWERWKRIWKHPDLQIHHGZDWHU

SLSLQJOLQHVDQGLVORFDWHGLQ9ROXPHVDQG7KHIHHGZDWHUSXPSVUHFLUFXODWLRQ

OLQHVWRWKHFRQGHQVHU):'(DQG):'(DUHURXWHGIURPWKHGLVFKDUJHRI

HDFKIHHGZDWHUSXPSWRWKHFRQGHQVHULQOHWQR))OHV7KHLUKLJKHQHUJ\\ERXQGDULHV

DUHWKHIHHGZDWHUOLQHVDQGWKHFRQGHQVHU7KHVHOLQHVDUHURXWHGIURP9ROXPH

WKURXJKWKHZDOOLQWRWKHFRQGHQVHUDUHD 9ROXPH WRWKHFRQGHQVHU7KHRWKHU

IHHGZDWHUSLSLQJ):'(DQG):('DUHORFDWHGLQWKHFRQGHQVHUDUHD

9ROXPH 7KHLUERXQGDULHVDUHWKHPDLQIHHGZDWHUOLQHVDQGYDOYH):

,

&RQGHQVDWH6\\VWHP

7KHKLJKHQHUJ\\&RQGHQVDWH6\\VWHPOLQHVDUHORFDWHGLQWKHFRQGHQVHUDUHD

9ROXPH 7XUELQH%XLOGLQJSLSHFKDVHDUHD 9ROXPH DQGUHDFWRUIHHGZDWHU

SXPSDUHD 9ROXPHVDQG 7KHKLJKHQHUJ\\&RQGHQVDWH6\\VWHPSLSLQJLQFOXGHV

WKHPDLQFRQGHQVDWHV\\VWHPSLSLQJ &$*%DQG&%*% DQGWKH

FRQGHQVDWHFURVVWLH &*% 7KHERXQGDULHVRIWKHFRQGHQVDWHOLQHVDUHWKH

RXWOHWQR))OHVRIWKHVHFRQGVWDJHLQWHUPHGLDWHKHDWHUV($ (%DQGWKH

VXFWLRQQR))OHVRIWKHIHHGZDWHUSXPSV3$DQG3%7KHQRUPDORSHUDWLQJ

SUHVVXUHRIWKHFRQGHQVDWHOLQHVLVSVLJDQGLVWKHUHIRUHQRWKLJKHQHUJ\\7KH

SLSLQJGRZQVWUHDPRIWKH(KHDWHUVLVFRQVHUYDWLYHO\\FODVVLILHGDVKLJKHQHUJ\\

,

+3&, 6WHDP 6\\VWHP

7KHKLJKHQHUJ\\SLSLQJRQWKH+3&,V\\VWHPLVWKHVWHDPVXSSO\\OLQH 36(' 

7KH+3&,VWHDPVXSSO\\OLQHLVURXWHGIURPFRQWDLQPHQWSHQHWUDWLRQ;WRWKH+3&,

VWHDPVXSSO\\YDOYH02ORFDWHGQHDUWKH+3&,WXUELQH3LSLQJEHWZHHQ

FRQWDLQPHQWSHQHWUDWLRQ;DQGWKHRXWERDUGSULPDU\\FRQWDLQPHQWLVRODWLRQYDOYH

02KDVEHHQHYDOXDWHGSHUWKHFULWHULDGHILQHGLQ,  E 7KHUHPDLQLQJ

SRUWLRQVRIWKLVOLQHIURPWKH02WRWKH+3&,WXUELQHUHTXLUHQRIXUWKHU+(/%

HYDOXDWLRQEHFDXVHWKLVSRUWLRQRIWKHOLQHLVSUHVVXUL]HGOHVVWKDQRIWKHWLPH

7KH+3&,VWHDPVXSSO\\OLQHEHJLQVLQWKHPDLQVWHDPFKDVH 9ROXPH LVURXWHG

WKURXJKWKHWRUXVDUHD 9ROXPH DQGWHUPLQDWHVLQWKH+3&,FRPSDUWPHQW

9ROXPH 

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

5&,& 6WHDP 6\\VWHP

7KHRQO\\KLJKHQHUJ\\OLQHIRUWKH5&,& 6WHDP 6\\VWHPLVWKHVWHDPVXSSO\\OLQH

36('7KLVOLQHLVURXWHGIURPWKHFRQWDLQPHQWSHQHWUDWLRQ;WRWKHWXUELQH

VWHDPVXSSO\\YDOYH023LSLQJEHWZHHQFRQWDLQPHQWSHQHWUDWLRQ;DQGWKH

RXWERDUGSULPDU\\FRQWDLQPHQWLVRODWLRQYDOYH02KDVEHHQHYDOXDWHGSHUWKH

FULWHULDGHILQHGLQ,  E 7KHUHPDLQLQJSRUWLRQRIWKLVOLQHIURP02WR

WKH5&,&WXUELQHUHTXLUHQRIXUWKHU+(/%HYDOXDWLRQEHFDXVHWKLVSRUWLRQRIWKHOLQHLV

SUHVVXUL]HGOHVVWKDQRIWKHWLPH

7KH5&,&VWHDPVXSSO\\OLQHEHJLQVLQWKHPDLQVWHDPFKDVH 9ROXPH LVURXWHG

WKURXJKWKHWRUXVDUHD 9ROXPH DQGWHUPLQDWHVLQWKH5&,&FRPSDUWPHQW

9ROXPH 

,

5HDFWRU:DWHU&OHDQXS 5:&8 6\\VWHP

7KHKLJKHQHUJ\\SLSLQJ5:&86\\VWHPFRQVLVWVRIWKH5:&8VXSSO\\OLQHIURPWKH

SULPDU\\FRQWDLQPHQWSHQHWUDWLRQ;WKURXJKWKHKHDWH[FKDQJHUV

5(:'%''&''% WKHE\\SDVVSLSLQJDURXQGWKHUHJHQHUDWLYHKHDW

H[FKDQJHU 5(:'%' WKHFURVVWLHIURPWKHVXSSO\\OLQHWRYDOYH5&

5(:'%' DQGWKHUHWXUQOLQHIURPWKHUHJHQHUDWLYHKHDWH[FKDQJHUWRWKH

+3&,DQG5&,&LQMHFWLRQOLQHV 5(:'%''&(' 7KHSLSLQJLVURXWHGIURPWKH

SULPDU\\FRQWDLQPHQWSHQHWUDWLRQLQWKH5:&8DUHD 9ROXPH WKURXJKWKHKHDW

H[FKDQJHUVLQWKH5:&8DUHD 9ROXPHDQG WKURXJKWKH5HDFWRU

%XLOGLQJDWIRRWHOHYDWLRQ 9ROXPH DQGWKH0*VHWURRP 9ROXPH WKURXJK

WKHZHVWVLGHRIWKH5HDFWRU%XLOGLQJDWWKHIRRWHOHYDWLRQ 9ROXPH DQG

WHUPLQDWHVEDFNLQWKHPDLQVWHDPFKDVH 9ROXPH 3LSLQJEHWZHHQFRQWDLQPHQW

SHQHWUDWLRQ;DQGWKHRXWERDUGSULPDU\\FRQWDLQPHQWLVRODWLRQYDOYH02KDV

EHHQHYDOXDWHGSHUWKHFULWHULDGHILQHGLQ,  E 

,

,QVWUXPHQWDQG6DPSOH/LQHV

7KHLQVWUXPHQWVHQVLQJOLQHVIURPWKHSULPDU\\FRROLQJV\\VWHPDQGUHDFWRUYHVVHOWR

WKHLQVWUXPHQWDWLRQUHSUHVHQWKLJKHQHUJ\\OLQHVIRUWKHSRUWLRQRIWKHURXWLQJRXWVLGH

RIWKH3ULPDU\\&RQWDLQPHQW6LQFHDOORIWKHVHOLQHVDUHLQFKRUVPDOOHULQQRPLQDO

VL]HQHLWKHUFLUFXPIHUHQWLDOEUHDNVQRUORQJLWXGLQDOEUHDNVDUHUHTXLUHGWREH

SRVWXODWHG,QDGGLWLRQDOOOLQHVDUHHTXLSSHGZLWKH[FHVVIORZFKHFNYDOYHVZKLFK

ZRXOGPLWLJDWHDQ\\EUHDNZLWKLQDIHZVHFRQGVRIWKHEUHDNRFFXUULQJ

$OOLQVWUXPHQWDQGVDPSOHOLQHVZKLFKWHHIURPRWKHUKLJKHQHUJ\\OLQHVDUHLGHQWLILHG

DQGHYDOXDWHGZLWKWKHVSHFLILFV\\VWHP

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

&RUH6SUD\\6\\VWHP

LWKLQWKH&RUH6SUD\\ &6 6\\VWHPRQO\\DVPDOOSRUWLRQRIHDFKLQMHFWLRQOLQH

7:('DQG7:(' ZDVGHWHUPLQHGWREHKLJKHQHUJ\\SLSLQJ7KHSRUWLRQ

RIWKHLQMHFWLRQOLQHVLGHQWLILHGDVKLJKHQHUJ\\UXQVIURPWKHFRQWDLQPHQWSHQHWUDWLRQ

RXWWRWKHLQERDUGFRQWDLQPHQWLVRODWLRQYDOYHV02DQG02UHVSHFWLYHO\\

/LQH7:('IURPSULPDU\\FRQWDLQPHQWSHQHWUDWLRQ;$WRYDOYH02LV

ORFDWHGHQWLUHO\\ZLWKLQWKHUHDFWRUZDWHUFOHDQXSFRPSDUWPHQW 9ROXPH 7KH

UHPDLQLQJ&RUH6SUD\\OLQH7:('IURPSULPDU\\FRQWDLQPHQWSHQHWUDWLRQ;%

WRYDOYH02LVORFDWHGZLWKLQDEORFNZDOOFRPSDUWPHQW 9ROXPH DERYHWKH

5HDFWRU%XLOGLQJOHYHO%RWKOLQHVKDYHEHHQHYDOXDWHGWRPHHWWKHFULWHULD

GHILQHGLQ,  E 7KHUHPDLQLQJSRUWLRQVRIWKHVHOLQHVIURPWKHLQERDUG

FRQWDLQPHQWLVRODWLRQYDOYHVWRWKH&RUH6SUD\\SXPSGLVFKDUJHQR))OHVZHUH

GHWHUPLQHGWRUHTXLUHQRIXUWKHU+(/%HYDOXDWLRQEHFDXVHWKHVHOLQHVDUHQRW

SUHVVXUL]HGPRUHWKDQRIWKHWLPH3RUWLRQVRIFRUHVSUD\\SLSLQJKDYHGHVLJQ

WHPSHUDWXUHVWKDWKDYHLQFUHDVHGIURP)WR)DVDUHVXOWRI(387KXV

WKHVHOLQHVDUHQRZFODVVLILHGDV+(/%OLQHVEXWUHTXLUHQRIXUWKHU+(/%HYDOXDWLRQ

EHFDXVHWKHVHOLQHVDUHQRWSUHVVXUL]HGPRUHWKDQRIWKHWLPH

,

5HVLGXDO+HDW5HPRYDO 5+5 6\\VWHP

7KHRQO\\SRUWLRQVRIWKH5+56\\VWHPFRQVLGHUHGKLJKHQHUJ\\SLSLQJDUHRQWKH/3&,

LQMHFWLRQOLQHV 7:'%DQG7:'% IURPWKHSULPDU\\FRQWDLQPHQW

SHQHWUDWLRQVWRWKHLQERDUGFRQWDLQPHQWLVRODWLRQYDOYHV02DQG02

UHVSHFWLYHO\\DQGWKHVKXWGRZQFRROLQJVXFWLRQOLQH5(:'%IURPWKH

FRQWDLQPHQWSHQHWUDWLRQWRWKHRXWERDUGFRQWDLQPHQWLVRODWLRQYDOYH02/LQH

7:'%LVORFDWHGLQWKHZHVWVKXWGRZQFRROLQJURRP 9ROXPH DQG

WHUPLQDWHVDWSHQHWUDWLRQ;$DQGYDOYH02/LQH7:'%LVORFDWHGLQ

WKHHDVWVKXWGRZQFRROLQJURRP 9ROXPH DQGWHUPLQDWHVDWSHQHWUDWLRQ;%

DQGYDOYH02/LQH5(:'%LVORFDWHGLQ9ROXPHDQGWHUPLQDWHVDW

SHQHWUDWLRQ;DQGYDOYH02$OORIWKHVHOLQHVKDYHEHHQHYDOXDWHGSHUWKH

FULWHULDGHILQHGLQ,  E 7KHUHPDLQLQJSRUWLRQVRIWKHVHOLQHVIURPWKH

LQERDUGFRQWDLQPHQWLVRODWLRQYDOYHVWRWKH5+5SXPSGLVFKDUJHQR))OHUHTXLUHQR

IXUWKHU+(/%HYDOXDWLRQEHFDXVHWKHVHOLQHVDUHSUHVVXUL]HGOHVVWKDQRIWKH

WLPH

7KHUHPDLQLQJ5+56\\VWHPOLQHVZHUHGHWHUPLQHGWRQRWUHTXLUHIXUWKHU+(/%

HYDOXDWLRQ$OORIWKHSLSLQJFRPSULVLQJWKHVKXWGRZQFRROLQJPRGHRI5+5ZHUH

LGHQWLILHGDVH[HPSWIURP+(/%HYDOXDWLRQVEHFDXVHLWLVSUHVVXUL]HGOHVVWKDQRI

WKHWLPH 5HIHUHQFH 3RUWLRQVRI5+5SLSLQJKDYHGHVLJQWHPSHUDWXUHVWKDWKDYH

LQFUHDVHGIURP)WR)DVDUHVXOWRI(387KXVWKHVHOLQHVDUHQRZ

FODVVLILHGDV+(/%OLQHVEXWUHTXLUHQRIXUWKHU+(/%HYDOXDWLRQEHFDXVHWKHVHOLQHV

DUHQRWSUHVVXUL]HGPRUHWKDQRIWKHWLPH

,

+3&, :DWHU 6\\VWHP

7KHKLJKHQHUJ\\SRUWLRQFRQVLVWVRIWKH+3&,LQMHFWLRQOLQH7:('IURPWKH

+3&,LQMHFWLRQOLQHYDOYH 02 WRWKHIHHGZDWHUOLQH7KLVSRUWLRQRIWKHOLQHLV

ORFDWHGLQWKHVWHDPFKDVHDUHD 9ROXPH $OORWKHUSRUWLRQVRIWKH+3&,LQMHFWLRQ

OLQHDUHSUHVVXUL]HGOHVVWKDQRIWKHWLPHVRWKH\\GRQRWUHTXLUHIXUWKHUHYDOXDWLRQ



0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

5&,& :DWHU 6\\VWHP

7KHKLJKHQHUJ\\SRUWLRQFRQVLVWVRIWKH5&,&LQMHFWLRQOLQH):('IURPWKH

QRUPDOO\\FORVHG5&,&LQMHFWLRQYDOYH 02 WRWKH)HHGZDWHUOLQH7KLVSRUWLRQRI

WKHOLQHLVORFDWHGLQWKHVWHDPFKDVHDUHD 9ROXPH $OORWKHUSRUWLRQVRIWKH5&,&

LQMHFWLRQOLQHDQGIXOOIORZWHVWOLQHDUHSUHVVXUL]HGOHVVWKDQRIWKHWLPHVRWKH\\GR

QRWUHTXLUHIXUWKHUHYDOXDWLRQ

,

6WDQGE\\/LTXLG&RQWURO

/LQH&+'&IURPFRQWDLQPHQWSHQHWUDWLRQ;WRFKHFNYDOYH;3LVWKH

RQO\\KLJKHQHUJ\\SRUWLRQRIWKLVV\\VWHP,WLVORFDWHGLQWKHHDVWVKXWGRZQFRROLQJ

URRP 9ROXPH $WHUPLQDOHQGEUHDNDWWKHFRQWDLQPHQWSHQHWUDWLRQ;KDV

EHHQHYDOXDWHGSHUWKHFULWHULDGHILQHGLQ,  D 

,

2IIJDV6\\VWHP

)RUWKH2IIJDV6\\VWHPWKHQRUPDORSHUDWLQJWHPSHUDWXUHVDQGSUHVVXUHVZHUHXVHG

WRGHWHUPLQHWKHKLJKHQHUJ\\OLQHVRQWKHV\\VWHP+RZHYHUQROLQHVRIWKH2IIJDV

6\\VWHPZHUHH[FOXGHGIURPWKHOLVWRIKLJKHQHUJ\\SLSLQJEDVHGXSRQDQRSHUDWLQJ

SUHVVXUHOHVVWKDQSVLJ

LWKWKHH[FHSWLRQRIOLQHV6+3DQG*2/(DOORIWKHKLJKHQHUJ\\OLQHV

LQWKH2IIJDV6\\VWHPDUHORFDWHGLQWKH2IIJDV6WRUDJHDQG&RPSUHVVRU%XLOGLQJ

7KHVWHDPVXSSO\\OLQH6+3LVURXWHGIURPWKHFRQGHQVHUDUHD 9ROXPH 

WKURXJKWKH6-$(5RRP 9ROXPH 2QHERXQGDU\\IRUWKLVOLQHLVWKHWHHWROLQH

36('DQGWKHRWKHULVLQWKH2IIJDV6WRUDJHDQG&RPSUHVVRU%XLOGLQJ7KLVOLQH

LVWKHGLVFKDUJHOLQHIRUVDIHW\\YDOYH369%DQGKHQFHWKLVOLQHZRXOGRQO\\EH

SUHVVXUL]HGLIWKH369OLIWHG/LQH*2/(ZDVH[FOXGHGIURPFRQVLGHUDWLRQ

XQGHUWKHFULWHULRQ

,

&RQWURO5RG'ULYH6\\VWHP

LWKLQWKH&5'V\\VWHPRQO\\DVPDOOSRUWLRQRIWKH&5'UHWXUQOLQH &5''( 

EHWZHHQFKHFNYDOYH&5'DQGWKHWHHFRQQHFWLRQWRWKH5:&8UHWXUQOLQH

5(:'& LVGHWHUPLQHGWREHKLJKHQHUJ\\SLSLQJ7KLVOLQHLVORFDWHGLQWKH

5HDFWRU%XLOGLQJIRRWIORRU 9ROXPH 7KHUHPDLQLQJ6FUDP'LVFKDUJH9ROXPH

DQGDVVRFLDWHGSLSLQJDUHSUHVVXUL]HGDERYHSVLJRQO\\DIWHUVFUDPLQLWLDWLRQ

7KHUHIRUHWKHVHOLQHVDUHH[FOXGHGEDVHGRQWKHXVDJHFULWHULD 5HIHUHQFHV

DQG 

,

=LQF2[LGH,QMHFWLRQ6\\VWHP *(=,3 

7KHV\\VWHPFRQVLVWVRIWKUHHLQFKOLQHVZLWKRQHRQWKHVXFWLRQSLSHRIHDFK

IHHGZDWHUSXPSDQGWKHWKLUGRQIHHGZDWHUSXPS3%GLVFKDUJHOLQH7KHHQWLUH

  • (=,3LVFRQVLGHUHGKLJKHQHUJ\\SLSLQJORFDWHGLQWKHIHHGZDWHUSXPSDUHD

9ROXPH 

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

+LJK(QHUJ\\/LQH'HVLJQDWLRQ/LVW

7DEOH,SURYLGHVDOLVWRIDOOKLJKHQHUJ\\OLQHVFRQVLGHUHGLQWKLVHYDOXDWLRQ,Q

DGGLWLRQWRLGHQWLI\\LQJWKHKLJKHQHUJ\\OLQHVIRUHDFKV\\VWHPFRQVLGHUHGLQIRUPDWLRQLV

SURYLGHGIRUHDFKOLQH¶VORFDWLRQWHUPLQDOSRLQWVQRUPDORSHUDWLQJRUGHVLJQFRQGLWLRQV

,QIRUPDWLRQIRUHDFK+(OLQHZLWKLQDFRPSDUWPHQWZDVFRPSLOHGE\\VLWHLQVSHFWLRQDQG

UHFRUGHGLQVXUYH\\ERRNV 5HIHUHQFHVDQG 

7KHIROORZLQJGHVFULSWLRQVLGHQWLI\\WKHLQIRUPDWLRQSURYLGHGLQHDFKFROXPQRI

7DEOH,

&ROXPQ

6\\VWHP,GHQWLILHVWKHQDPHRIWKHSODQWV\\VWHPFRQWDLQLQJ+(

OLQH

&ROXPQ

3 ,',GHQWLILHVWKH³0'QXPEHURUGUDZLQJQXPEHUIRUWKH3 ,'

FRQWDLQLQJWKHOLQH

&ROXPQ

9ROXPH,GHQWLILHVWKHYROXPHLQWKH5HDFWRU%XLOGLQJ 5% RU

7XUELQH%XLOGLQJ 7% ZKHUHWKH+(OLQHLVORFDWHG9ROXPHVIRU

SLSLQJH[FOXGHGIURP+(/%HYDOXDWLRQEDVHGWKHFULWHULD

PD\\QRWEHVKRZQ

&ROXPQ

/LQH'HVLJQDWLRQ,GHQWLILHVSODQWOLQHQXPEHURI+(OLQH

&ROXPQV 

)URP7R,GHQWLILHVWKHVHJPHQWRIWKH+(OLQHE\\RIILFLDOSODQW

QXPEHU7KH)URP7RSRLQWVPD\\EHDSXPSKHDWH[FKDQJHU

DQRWKHUSLSHWDQNHWF

&ROXPQV

'HVLJQRU1RUPDO&RQGLWLRQV,GHQWLILHVWKHGHVLJQSUHVVXUHDQG

QRUPDORSHUDWLQJWHPSHUDWXUHDJDLQVWZKLFKWKHOLQHZDV

LGHQWLILHGDVD+(OLQH,IQRUPDORSHUDWLQJWHPSHUDWXUHLVQRW

NQRZQWKHGHVLJQWHPSHUDWXUHZDVFRQVHUYDWLYHO\\XVHG7KH

WDEOHLVFRQVHUYDWLYHO\\EDVHGRQGHVLJQSUHVVXUHUDWKHUWKDQ

RSHUDWLQJSUHVVXUH

&ROXPQV

+(/%EUHDNVDQGFUDFNVSRVWXODWHGLQ6HFWLRQ,DUHQRW

SRVWXODWHGLQ+(OLQHVWKDWKDYHWKHIROORZLQJH[FOXVLRQV

7KHH[FOXVLRQVLQFOXGHGSLSLQJZLWKRSHUDWLQJSUHVVXUHDERYH

SVLJRULWVRSHUDWLQJWHPSHUDWXUHDERYH)IRUOHVVWKDQ

RIQRUPDORSHUDWLQJWLPH 5HIHUHQFH0(%%H 

0RGHUDWHHQHUJ\\OLQHVDUHQRWSRVWXODWHGSHUVHFWLRQ,

5HIHUHQFH ([FHSWLRQWRWKHUXOHLVQRWHGLQWKHWDEOH

ZKHUHXVHG

³63' VXSHUSLSH ZDVXVHGWRGHVLJQDWHWKDWEUHDNVZHUHQRW

UHTXLUHGWREHSRVWXODWHGSHUVHFWLRQ,7KLVSRUWLRQRI

SLSLQJKDVEHHQHYDOXDWHGSHUWKHFULWHULDGHILQHGLQ6HFWLRQ

,  E 

6PDOOGLDPHWHUSLSLQJLQFKDQGOHVVLVQRWLQFOXGHGLQWKLV

WDEOH

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,

+LJK(QHUJ\\3LSLQJ/LVW



+,*+(1(5*</,1('(6,*1$7,21/,67

6\\VWHP

3 ,' V 

9ROXPH V 

/LQH

)URP

7R

3UHVV 7HPS ([FOXVLRQ V 







'HVLJQDWLRQ





SVLJ

)



63

0DLQ6WHDP

0

5%

36('

$

$2$



 



0DLQ6WHDP

0

5% 7%

36('

$2$

69



 



0DLQ6WHDP

0

5%

36('

%

$2%



 



0DLQ6WHDP

0

5% 7%

36('

$2%

69



 



0DLQ6WHDP

0

5%

36('

&

$2&



 



0DLQ6WHDP

0

5% 7%

36('

$2&

69



 



0DLQ6WHDP

0

5%

36('

'

$2'



 



0DLQ6WHDP

0

5% 7%

36('

$2'

69



 



0DLQ6WHDP

0

7% 7%

36

&9

+37XUELQH*



 



0DLQ6WHDP

0

7%

36

&9

+37XUELQH*



 



0DLQ6WHDP

0

7%

36

&9

+37XUELQH*



 



0DLQ6WHDP

0

7% 7%

36

&9

+37XUELQH*



 



0DLQ6WHDP

0

5%

36('

36('

&DS



 



0DLQ6WHDP

0

5%

36('

36('

&DS



 



0DLQ6WHDP

0

5%

36('

36('

&DS



 



0DLQ6WHDP

0

5%

36('

36('

&DS



 



0DLQ6WHDP

0

7%

36('

%3&9

($



 



0DLQ6WHDP

0

7%

36('

%3&9

($



 



0DLQ6WHDP

0

7%

36('

36('

&DS



 



0DLQ6WHDP

0

7%

36('

36('

36('



 



0DLQ6WHDP

0

7%

36('

36('

36



 



0DLQ6WHDP

0

7%

36('

36('

%3&9



 



0DLQ6WHDP

0

7%

36('

36('

%3&9



 



0DLQ6WHDP

0

7%

36('

36('

36('



 



0DLQ6WHDP

0

7%

36('

36('

36('



 



0DLQ6WHDP

0

7%

36('

36('

06



 



0DLQ6WHDP

0

7%

36('

36('

06



 



0DLQ6WHDP

0

7%

36('

36('

06



 





0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,+LJK(QHUJ\\3LSLQJ/LVW &RQW¶G 



+,*+(1(5*</,1('(6,*1$7,21/,67

6\\VWHP

3 ,' V 

9ROXPH V 

/LQH

)URP

7R

3UHVV 7HPS ([FOXVLRQ V 







'HVLJQDWLRQ





SVLJ

)



63

0DLQ6WHDP

0

7%

36('

36('

06



 



0DLQ6WHDP

0

7%

36('

36('

36('



 



0DLQ6WHDP

0

7%

36('

36('

36('



 



0DLQ6WHDP

0

7%

36('

36('

36('



 



0DLQ6WHDP

0

7%

36('

36('

36('



 



0DLQ6WHDP

0

5%

36('



02



 



0DLQ6WHDP

0

5%

36(%

02

6XSSRUW65



 



0DLQ6WHDP

0

5%

36(%

6XSSRUW65

02



 



0DLQ6WHDP

0

5%

36()

02

[5HG(OERZ



 



0DLQ6WHDP

0

5%7%

'()(%

[5HG(OERZ

&RQGHQVHU($



 



0DLQ6WHDP

0

7%

36('

36('

52



 



0DLQ6WHDP

0

7%

36(%'

36('

36('



 



0DLQ6WHDP

0

7%

36(%'

36('

36('



 



0DLQ6WHDP

0

7%

36(%'

36('

36('



 



0DLQ6WHDP

0

7%

36(%'

36(%'

&DS



 



0DLQ6WHDP

0

7%

06%UDQFK

36(%'

06



 



0DLQ6WHDP

0

5%

'('

36('

'('



 



0DLQ6WHDP

0

5%

'('

36('

'('



 



0DLQ6WHDP

0

5%

'('

36('

'('



 



0DLQ6WHDP

0

5%

'('

36('

'('



 



0DLQ6WHDP

0

5%

'('

&DS

02



 



0DLQ6WHDP

0

5%

'(%

02

36(%



 



0DLQ6WHDP

0

7%

'(%

'(%

02



 



0DLQ6WHDP

0

7%

'(%'

36(%'

02



 



0DLQ6WHDP

0

7%

'()

02

'()



 



0DLQ6WHDP

0

7%

'(%'

36(%'

52



 



0DLQ6WHDP

0

7%

'()

52

'()



 



0DLQ6WHDP

0

7%

36

36('

02



 



0DLQ6WHDP

0

7%

36

36

02



 



0DLQ6WHDP

0

7%

36

02

6WHDP6HDO

5HJXODWRU



 





0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,+LJK(QHUJ\\3LSLQJ/LVW &RQW¶G 



+,*+(1(5*</,1('(6,*1$7,21/,67

6\\VWHP

3 ,' V 

9ROXPH V 

/LQH

)URP

7R

3UHVV 7HPS ([FOXVLRQ V 







'HVLJQDWLRQ





SVLJ

)



63

&RQGHQVDWH

0

7%µ

&$*%

+HDWHU($

+HDWHU($





 



&RQGHQVDWH

0

7%

&$*%

+HDWHU($

3$









&RQGHQVDWH

0

7%

&$'(

&$*%

):









&RQGHQVDWH

0

7%

&%*%

+HDWHU(%

+HDWHU(%





 



&RQGHQVDWH

0

7%

&%*%

+HDWHU(%

3%









&RQGHQVDWH

0

7%

&%'(

&%*%

):









&RQGHQVDWH

0

7%

&*%

&$*%

&%*%









)HHGZDWHU

0

7%

):'(

):$'(

):%'(









)HHGZDWHU

0

7%

):'(

):'(

):$'(









)HHGZDWHU

0

7%

):'(

):'(

):%'(









)HHGZDWHU

0

7%

):$'(

3$

($









)HHGZDWHU

0

7%

):$'(

($

($









)HHGZDWHU

0

7%

):$'(

($

02









)HHGZDWHU

0

7% 5% ):$('

02

):









)HHGZDWHU

0

5%

):$('

):

):









)HHGZDWHU

0

5%

):$('

):

%









)HHGZDWHU

0

7%

9%'(

):%'(

):









)HHGZDWHU

0

7%

):%'(

(%

(%









)HHGZDWHU

0

7%

):%'(

(%

02









)HHGZDWHU

0

7% 5% ):%('

02

):









)HHGZDWHU

0

5%

):%('

):

):









)HHGZDWHU

0

5%

):%('

):

$









)HHGZDWHU

0

7%

):'(

):$'(

&9









)HHGZDWHU

0

7%

):'(

):%'(

&9









)HHGZDWHU

0

7%

):'(

):$%'(

):









)HHGZDWHU

0

7%

):'(

):

):









)HHGZDWHU

0

7%

):('

):$('

):%('











0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,+LJK(QHUJ\\3LSLQJ/LVW &RQW¶G 



+,*+(1(5*</,1('(6,*1$7,21/,67

6\\VWHP

3 ,' V 

9ROXPH V 

/LQH

)URP

7R

3UHVV 7HPS ([FOXVLRQ V 







'HVLJQDWLRQ





SVLJ

)



63

)HHGZDWHU

0

7%

):$'(

):$'(

3$









)HHGZDWHU

0

7%

):%UDQFK

):$'(

):









)HHGZDWHU

0

7%

):%'(

):%'(

3%









)HHGZDWHU

0

7%

):%UDQFK

):%'(

):









&5'

0

5%

&5''(

5(:'&

µZHVW&5'+









&5'

0



&5''&

&5''&

&5'$'&









&5'

0



&5''&

&5''&

&5'%'&









&5'

0



&5''&

&5''&

&5'&'&









&5'

0



&5''&

&5''&

&5'''&









&5'

0



&5''&

&5''&

5HGXFHU









&5'

0



&5'$'%

&5'$&&'

&5'$&&'









&5'

0



&5'%'%

&5'%&&'

&5'%&&'









&5'

0



&5'$'%

&5'$&&'

&5'$&&'









&5'

0



&5'%'%

&5'%&&'

&5'%&&'









&5'

0



&5'$'%

&5'$&&'

&5'$&&'









&5'

0



&5'%'%

&5'%&&'

&5'%&&'









&5'

0



&5'$&&'

&5'$&&'

%OLQG)ODQJH









&5'

0



&5'$&&'

&5'$&&'

&5'$&&'









&5'

0



&5'$&&'

&5'$&&'

&9&









&5'

0



&5'%&&'

&5'%&&'

%OLQG)ODQJH









&5'

0



&5'%&&'

&5'%&&'

&5'%&&'









&5'

0



&5'%&&'

&5'%&&'

&9'









5+5

0



7:*(

7:*(

3%









5+5

0



7:*(

7:*(

3'









5+5

0



7:*(

7:*(

(%









5+5

0



7:*(

7:*(

3$









5+5

0



7:*(

7:*(

3&









5+5

0



7:*(

7:*(

($









5+5

0



7:*(

(%

7:*(









5+5

0



7:*(

(%

7:*(









5+5

0



3$6%UDQFK

7:*(

3$6











0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,+LJK(QHUJ\\3LSLQJ/LVW &RQW¶G 



+,*+(1(5*</,1('(6,*1$7,21/,67

6\\VWHP

3 ,' V 

9ROXPH V 

/LQH

'HVLJQDWLRQ

)URP

7R

3UHVV

SVLJ

7HPS

)

([FOXVLRQ V 



63

5+5

0



7:*(

7:*(

02









5+5

0



5+5%UDQFK

7:*(

5+5









5+5

0



7:'%

02

02









5+5

0

5%

7:'%

02

$









5+5

0



7:*(

7:*(

52









5+5

0



7:*(

7:*(

52









5+5

0



7:*(

7:*(

7:*(









5+5

0



7:*(

7:*(

7:+









5+5

0



7:*(

7:+

7:*(









5+5

0



7:*(

7:*(

7:*(









5+5

0



7:*(

($

7:*(









5+5

0



5+5%UDQFK

7:*(

5+5









5+5

0



7:*(

($

7:*(









5+5

0



3$6%UDQFK

7:*(

3$6









5+5

0



7:*(

7:*(

02









5+5

0



7:'%

02

02









5+5

0

5%

7:'%

02

%









5+5

0



7:*(

7:*(

52









5+5

0



7:*(

7:*(

52









5+5

0



7:*(

7:*(

&DSSHG(QG









5+5

0



7:*(

7:*(

02









5+5

0

5%

5(:('



02









5+5

0



)3:*(

7:*(

3&









5+5

0



6:*(

7:*(

6:*)









5+5

0



'*(

7:*(

5+5









5+5

0



'*(

7:*(

5+5









5+5

0



'*(

7:*(

5+5









5+5

0



59*(

7:*(

59









5+5

0



59*(

7:*(

59









5+5

0



6&*&

&67

%UDQFKHV









5+5

0



6&$*&

6&*&

6&$*(











0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,+LJK(QHUJ\\3LSLQJ/LVW &RQW¶G 



+,*+(1(5*</,1('(6,*1$7,21/,67

6\\VWHP

3 ,' V 

9ROXPH V 

/LQH

'HVLJQDWLRQ

)URP

7R

3UHVV

SVLJ

7HPS

)

([FOXVLRQ V 



63

5+5

0



6&$*(

6&$*&

7:*(









5+5

0



6&%*&

6&*&

6&%*(









5+5

0



6&%*(

6&%*&

5(:+(









5+5

0



6&&*&

6&*&

6&&*(









5+5

0



6&&*(

6&&*&

7:*(









5+5

0



6&'*&

6&*&

6&'*(









5+5

0



6&'*(

6&'*&

7:*(









5+5

0



6&*&

&67

%UDQFKHV









5+5

0



6&*&

6&*&

6&*(









5+5

0



6&*(

6&*&

7:*(









5+5

0



6&%*&

6&*&

6&%*(









5+5

0



6&%*(

6&%*&

7:*(









5+5

0



7:*(

7:

02









5+5

0



7:*(

02

$









5+5

0



7:*(

7:

02









5+5

0



7:*(

02

02









5+5

0



7:*(

7:

02









5+5

0



7:*(

7:

02









5+5

0



7:*(

02

02









5+5

0



7:*(

7:

02









&RUH6SUD\\

0



7:*(

3$

02









&RUH6SUD\\

0



7:*(

7:

52









&RUH6SUD\\

0



7:+(

7:

52









&RUH6SUD\\

0



6&*(

7:

&67









&RUH6SUD\\

0



7:*(

3%

02









&RUH6SUD\\

0



7:*(

7:

52









&RUH6SUD\\

0



7:+(

7:

52









&RUH6SUD\\

0



6&*(

6&*(

7:*(









&RUH6SUD\\

0

5%

7:('

$

02









&RUH6SUD\\

0



7:('

02

02









&RUH6SUD\\

0

5%

7:('

%

02











0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,+LJK(QHUJ\\3LSLQJ/LVW &RQW¶G 



+,*+(1(5*</,1('(6,*1$7,21/,67

6\\VWHP

3 ,' V 

9ROXPH V 

/LQH

)URP

7R

3UHVV 7HPS ([FOXVLRQ V 







'HVLJQDWLRQ





SVLJ

)



63

&RUH6SUD\\

0



7:('

02

02









+3&, 6WHDP 

0

5%

36('



02









+3&, 6WHDP 

0

5%

36('

02

02









+3&, 6WHDP 

0

5%

36('

02

+2









+3&, 6WHDP 

0

5%

+HDWLQJ6WHDP&RQQ

36('

&DS









+3&, :DWHU 

0

5%

7:('

):%('

02









+3&, :DWHU 

0

5%

7:('

02

65









5&,& :DWHU 

0

5%

):('

):$('

$2









5&,& :DWHU 

0

5%

):('

$2

02









5&,& :DWHU 

0

5%

):('

02

02









5&,& :DWHU 

0

5%

):('

02

02









5&,& 6WHDP 

0

5%

36('



02









5&,& 6WHDP 

0

5%

36('

02

65









5&,& 6WHDP 

0

5%

+HDWLQJ6WHDP&RQQ

36('

&DS









5&,& 6WHDP 

0

5%

36('

65

02









5&,& 6WHDP 

0

5%

36('

02

02









6/&

0

5%

&+'&


3









6/&

0

5%

&+'&

3
3$









6/&

0

5%

&+'&

3
3%









6/&

0

5%

3%UDQFK

&+'&

3









5:&8

0

5%

5(:('



02









5:&8

0

5%

5(:'%'

02

5&









5:&8

0

5%

7(%UDQFK

5(:'%'

7(









5:&8

0

5%

5(:'%'

02

5&









5:&8

0

5%

5(:'%'

02

(  









5:&8

0

5%

5(:'%'

(  

(  









5:&8

0

5%

5(:'%'

(  

(  









5:&8

0

5%

5(:'%'

5&

(  









5:&8

0

5%

5(:'%'

(  

(  









5:&8

0

5%

7(%UDQFK

5(:'%

7(









5:&8

0

5%

5(:'%'

(  

02











0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,+LJK(QHUJ\\3LSLQJ/LVW &RQW¶G 



+,*+(1(5*</,1('(6,*1$7,21/,67

6\\VWHP

3 ,' V 

9ROXPH V 

/LQH

)URP

7R

3UHVV 7HPS ([FOXVLRQ V 







'HVLJQDWLRQ





SVLJ

)



63

5:&8

0

5%

7(%UDQFK

5(:'%'

7(









5:&8

0

5%

5(:'&

02

&5'7HH









5:&8

0

5%

5(:'&

&5'7HH

65









5:&8

0

5%

5(:'&

65

):7HH









5:&8

0

5%

5(:'%

):7HH

5&









5:&8

0

5%

5(:('

5&

7:('









5:&8

0

5%

5(:'%

):7HH

):('









2II*DV

1+

2IIJDV%XLOGLQJ 

&1(1&

($

9$









2II*DV

1+

2IIJDV%XLOGLQJ 

&1(1&

(%

9%









2II*DV

1+

2IIJDV%XLOGLQJ 

  • 2/(+1&

369%

(%









2II*DV

1+

2IIJDV%XLOGLQJ 

  • 2/(+1&

369$

  • 2/(+1&









2II*DV

1+

7%

6+3+1&

36('

7%:DOO









2II*DV

1+

2IIJDV%XLOGLQJ 

6+3+1&

7%:DOO

3&9$









2II*DV

1+

2IIJDV%XLOGLQJ 

6+3(1&

3&9$

-$









2II*DV

1+

2IIJDV%XLOGLQJ 

6+3+1&

6+3+1&

3&9%









2II*DV

1+

2IIJDV%XLOGLQJ 

603(1&

603((1&

($









2II*DV

1+

2IIJDV%XLOGLQJ 

603(1&

603((1&

(%









2II*DV

1+

2IIJDV%XLOGLQJ 

603((1&

-$

06









2II*DV

1+

2IIJDV%XLOGLQJ 

603(+1&

06

-$









2II*DV

1+

2IIJDV%XLOGLQJ 

603((1&

-%

06









2II*DV

1+

2IIJDV%XLOGLQJ 

603(+1&

06

-%









2II*DV

1+

2IIJDV%XLOGLQJ 

603(1&

6+3(1&

369$









2II*DV

1+

2IIJDV%XLOGLQJ 

603(1&

6+3(1&

369%









1RWH1RUPDORSHUDWLQJSUHVVXUHLVSVLJDQGWKHUHIRUHWKLVVHJPHQWLVQRWKLJKHQHUJ\\



0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

%UHDN$QDO\\VLV

7KHSRVWXODWHGEUHDNORFDWLRQVIRUHDFKKLJKHQHUJ\\OLQHDUHEDVHGRQWKHFULWHULD

HVWDEOLVKHGLQWKH*LDPEXVVROHWWHU 5HIHUHQFH 653 5HIHUHQFH DQG*HQHULF

/HWWHU 5HIHUHQFH 7KHV\\VWHPVHYDOXDWHGZHUHWKH0DLQ6WHDP+3&,5&,&

)HHGZDWHU&RQGHQVDWH5:&8DQGPLVFHOODQHRXVVHQVLQJDQGVDPSOHOLQHV

&DOFXODWLRQVZHUHSHUIRUPHGLQDFFRUGDQFHZLWKWKH³+(/%'(YDOXDWLRQ&ULWHULD

5HIHUHQFH WRGHWHUPLQHZKHUHWKHEUHDNORFDWLRQVZRXOGEHSRVWXODWHGIRUKLJKHQHUJ\\

SLSLQJ 5HIHUHQFH )RUHDFKV\\VWHPWKHFDOFXODWLRQUHVXOWVDUHOLVWHGEHORZ7KHEUHDN

ORFDWLRQVIRUKLJKHQHUJ\\OLQHVDUHVKRZQRQWKHGUDZLQJVSURYLGHGLQWKHILJXUHVVHFWLRQRI

WKLVDSSHQGL[

,

6HOHFWLRQRI%UHDN/RFDWLRQV

%UHDNORFDWLRQVZHUHSRVWXODWHGIRUDOOKLJKHQHUJ\\OLQHVVSHFLILHGLQ7DEOH,ZLWKRXW

DQH[FOXVLRQLQDFFRUGDQFHZLWKWKHIROORZLQJFULWHULD

,

&ODVV, /LQHVIRUZKLFKSLSLQJDQDO\\VHVWKDWLQFOXGHVVHLVPLFKDVEHHQSHUIRUPHG 

%UHDNVZHUHSRVWXODWHGIRUHDFK&ODVV,KLJKHQHUJ\\OLQHDVIROORZV

 

$WWHUPLQDOHQGV 0(%%F   5HIHUHQFH 

 

$WDQ\\LQWHUPHGLDWHORFDWLRQZKHUHQRUPDORSHUDWLQJDQGVHLVPLFVWUHVVHV

H[FHHGV 6K6$ RU 6$  0(%%F   5HIHUHQFH 

 

$WWKHWHUPLQDOHQGVRIWKHKLJKHQHUJ\\SLSLQJWKDWSHQHWUDWHVWKH3ULPDU\\

&RQWDLQPHQWERXQGDU\\7KHSRVWXODWHG+(/%VKDOOEHHLWKHU

D 

$WWKHSULPDU\\FRQWDLQPHQWSHQHWUDWLRQ7KLVSRLQWLVLGHQWLILHGDVWKH

ZHOGEHWZHHQWKHFRQWDLQPHQWSHQHWUDWLRQDQGWKHSLSLQJ

(YDOXDWLRQVZHUHSHUIRUPHGWRGHPRQVWUDWHWKDWWKHFRQWDLQPHQW

LQWHJULW\\LVPDLQWDLQHGZLWKD+(/%DWWKHFRQWDLQPHQWSHQHWUDWLRQ



RU

E 

$WWKHZHOGEHWZHHQWKHRXWERDUGFRQWDLQPHQWLVRODWLRQYDOYHDQG

WKHSLSLQJQRWZLWKLQWKH3ULPDU\\&RQWDLQPHQW3LSLQJEHWZHHQWKH

FRQWDLQPHQWSHQHWUDWLRQVDQGWKHRXWERDUGFRQWDLQPHQWLVRODWLRQ

YDOYHVKDVEHHQHYDOXDWHGWRPHHWWKHFULWHULDIRXQGLQ5HIHUHQFHV

DQG7KLVFULWHULDGRHVQRWUHTXLUHEUHDNVWREHSRVWXODWHGLQWKHVH

VHJPHQWV

 

,QDFFRUGDQFHZLWK*HQHULF/HWWHU 5HIHUHQFH VHLVPLFDOO\\DQDO\\]HG

DQGVXSSRUWHGKLJKHQHUJ\\OLQHVDUHQRWUHTXLUHGWRKDYHSRVWXODWHG

LQWHUPHGLDWH+(/%RUFULWLFDOFUDFNORFDWLRQVSURYLGHGWKDWWKHVWUHVVOHYHODW

HDFKSRWHQWLDOLQWHUPHGLDWHEUHDNORFDWLRQLVOHVVWKDQWKHYDOXHVLGHQWLILHGLQ

6HFWLRQ,  DERYH 5HIHUHQFH 

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





&ULWLFDOFUDFNVZHUHSRVWXODWHGZKHUHQRUPDORSHUDWLQJDQGVHLVPLFVWUHVVHVH[FHHG

 6K6$ &ULWLFDOFUDFNVDUHQRWUHTXLUHGWREHSRVWXODWHGLQSRUWLRQVRISLSLQJ

IURPWKHFRQWDLQPHQWZDOOWRDQGLQFOXGLQJWKHLQERDUGDQGRXWERDUGLVRODWLRQYDOYHV

0(%%H  +/-5HIHUHQFH 

,

&ODVV,, /LQHVIRUZKLFKQRVHLVPLFDQDO\\VHVKDVEHHQSHUIRUPHG 

%UHDNORFDWLRQVSRVWXODWHGIRUHDFK&ODVV,,KLJKHQHUJ\\OLQHZHUHVHOHFWHGDV

IROORZV

 

$WWHUPLQDOHQGV

 

$WHDFKLQWHUPHGLDWHORFDWLRQRISRWHQWLDOKLJKVWUHVVRUIDWLJXHVXFKDVSLSH

ILWWLQJVYDOYHVIODQJHVDQGZHOGHGRQDWWDFKPHQWV

 

&ULWLFDOFUDFNVZHUHSRVWXODWHGDWORFDWLRQVWKDWUHVXOWLQWKHPRVWVHYHUH

HQYLURQPHQWDOFRQVHTXHQFHV 0(%%H  +/-5HIHUHQFH 

,QWKRVHFDVHVZKHUHD&ODVV,,KLJKHQHUJ\\OLQHLVDQDO\\]HGWR&ODVV,SLSLQJVHLVPLF

UHTXLUHPHQWVEUHDNORFDWLRQVZHUHVHOHFWHGXVLQJWKHFULWHULDLQ6HFWLRQ,

,

%UHDNVLQ0RGHUDWH(QHUJ\\DQGRU1RQ+LJK(QHUJ\\/LQHV

01*3GRHVQRWVSHFLI\\0RGHUDWH(QHUJ\\OLQHVGHVFULEHGLQ*HQHULF/HWWHU

5HIHUHQFH +LJKHQHUJ\\OLQHEUHDNUXOHVRUKLJKHQHUJ\\OLQHFUDFNUXOHVGRQRW

VSHFLI\\WRSRVWXODWHKLJKHQHUJ\\OLQHEUHDNVRUKLJKHQHUJ\\OLQHFUDFNVLQQRQKLJK

HQHUJ\\OLQHV 5HIHUHQFHVDQG 

,

%UHDN7\\SHV

&LUFXPIHUHQWLDOEUHDNVZHUHSRVWXODWHGDQGHYDOXDWHGDWWHUPLQDOHQGV,QDGGLWLRQ

FLUFXPIHUHQWLDOEUHDNVZHUHSRVWXODWHGDWLQWHUPHGLDWHEUHDNORFDWLRQVRQKLJKHQHUJ\\

SLSLQJZLWKDQRPLQDOGLDPHWHUH[FHHGLQJLQFK/RQJLWXGLQDOEUHDNVZHUHSRVWXODWHGDW

DOOLQWHUPHGLDWHORFDWLRQVRQKLJKHQHUJ\\SLSLQJZLWKDQRPLQDOGLDPHWHUHTXDOWRRU

H[FHHGLQJLQFKHV/RQJLWXGLQDOEUHDNVZHUHSRVWXODWHGZLWKDQRULHQWDWLRQRIDQ\\SRLQW

DURXQGWKHSLSHFLUFXPIHUHQFHDQGDEUHDNDUHDHTXDOWRWKHHIIHFWLYHFURVVVHFWLRQDO

IORZDUHDLPPHGLDWHO\\XSVWUHDPRIWKHEUHDNORFDWLRQ &ULWHULRQ5HIHUHQFH 

&ULWLFDOFUDFNVZHUHSRVWXODWHGWRRFFXULQSLSLQJFDUU\\LQJKLJKHQHUJ\\IOXLGV7KHFULWLFDO

FUDFNVL]HZDVWDNHQWREHWKHSLSHGLDPHWHULQOHQJWKDQGWKHZDOOWKLFNQHVVLQ

ZLGWK &ULWHULRQ5HIHUHQFH 

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

+(/%,QWHUDFWLRQV

7KHHIIHFWVRQ6DIH6KXWGRZQ(TXLSPHQWIURPKLJKHQHUJ\\OLQHVFDQEHGLYLGHGLQWRILYH

 VHSDUDWHW\\SHVRILQWHUDFWLRQV7KHVHLQWHUDFWLRQVLQFOXGH



3LSH:KLS



-HW,PSLQJHPHQW



)ORRGLQJ



(QYLURQPHQWDO(IIHFWV



&RPSDUWPHQW3UHVVXUL]DWLRQ

7KHHYDOXDWLRQFULWHULDIRUHDFKRIWKHVHLQWHUDFWLRQVZDVSHUIRUPHGE\\DSSO\\LQJWKH

IROORZLQJFULWHULD

,

3LSH:KLS(IIHFWV

3LSHZKLSLVGHILQHGDVWKHPHFKDQLFDOUHDFWLRQFDXVHGE\\KLJKHQHUJ\\IOXLGH[LWLQJD

UXSWXUHGSLSH)RUHDFKSRVWXODWHGEUHDNWKHHIIHFWVRISLSHZKLSZHUHHYDOXDWHG

3LSHZKLSPRYHPHQWZDVDVVXPHGWRRFFXUDERXWDSODVWLFKLQJHORFDWHGDWDSRLQWRU

SRLQWVVHOHFWHGXVLQJWKHIROORZLQJJXLGHOLQHV 5HIHUHQFH 

 

7KHSLSHUXQWHUPLQDOSRLQW

 

7KHQHDUHVWSLSHILWWLQJZKLFKZLOOH[SHULHQFHKLJKEHQGLQJPRPHQW*HQHUDOO\\

WKLVZLOORFFXUDWWKHVHFRQGHOERZIURPWKHEUHDNSRLQW

 

$SLSHZKLSUHVWUDLQW

 

$Q\\VWUXFWXUHRUHTXLSPHQWZKLFKFDQUHDVRQDEO\\EHH[SHFWHGWRUHVWUDLQWKH

PRYHPHQWRIWKHSLSH HJFRQFUHWHZDOORUSUHVVXUHYHVVHO 

 

2UGLQDU\\SLSHVXSSRUWVZHUHFRQVLGHUHGLQHIIHFWLYHUHVWUDLQWVGXULQJZKLS

&LUFXPIHUHQWLDOEUHDNVZHUHDVVXPHGWRFDXVHSLSHZKLSDERXWWKHSODVWLFKLQJHLQD

SODQHGHILQHGE\\WKHSLSHJHRPHWU\\DQGLQWKHGLUHFWLRQRIMHWUHDFWLRQ &ULWHULRQ

%D5HIHUHQFH /RQJLWXGLQDOEUHDNVZHUHDVVXPHGWRFDXVHSLSHZKLS

PRYHPHQWLQWKHGLUHFWLRQRSSRVLWHRIWKHIOXLGIORZQRUPDOWRWKHD[LVRIWKHSLSHDW

WKHSRLQWRIWKHEUHDN )RRWQRWHWR&ULWHULRQ5HIHUHQFH $GGLWLRQDOO\\LWZDV

DVVXPHGWKDWWKHJHRPHWU\\RIWKHSLSHVHJPHQWEHWZHHQWKHVHOHFWHGKLQJHV

UHPDLQHGXQFKDQJHGWKURXJKRXWWKHSLSHZKLSSDWK

7KHDUHDRILQIOXHQFHRISLSHZKLSZDVFRQVLGHUHGWREHWKHZRUVWFDVHDUHD

GHWHUPLQHGDSSO\\LQJWKHFULWHULDLGHQWLILHGDERYH,QJHQHUDOFLUFXPIHUHQWLDOEUHDNV

FDXVHWKHZRUVWFDVHSLSHZKLSFRQGLWLRQV

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,QHYDOXDWLQJWKHHIIHFWRISLSHZKLSRQVDIHVKXWGRZQFRPSRQHQWVDQGVWUXFWXUHV

WKHIROORZLQJFULWHULDZHUHXVHG

 

7KHHQHUJ\\OHYHOLQDZKLSSLQJSLSHZDVFRQVLGHUHGWREHLQVXIILFLHQWWRUXSWXUH

DQLPSDFWHGSLSHRI

D 

(TXDORUJUHDWHUQRPLQDOSLSHVL]HDQG

E 

(TXDORUKHDYLHUZDOOWKLFNQHVV )RRWQRWHWR&ULWHULRQG

5HIHUHQFH 

 

,PSDFWHGSLSHRIOHVVHUQRPLQDOSLSHVL]HRUWKLQQHUZDOOWKLFNQHVVZDV

DVVXPHGWRUXSWXUHRUUHTXLUHIXUWKHUHYDOXDWLRQ )RRWQRWHWR&ULWHULRQG

5HIHUHQFH 

 

$OOHOHFWULFDOFDEOHVLQFDEOHWUD\\VFRQGXLWVRURWKHUUDFHZD\\VLPSDFWHGE\\D

ZKLSSLQJSLSHZHUHDVVXPHGWREHVHYHUHGRUUHTXLUHIXUWKHUHYDOXDWLRQ2WKHU

HOHFWULFDODQGLQVWUXPHQWDQGFRQWURO , & FRPSRQHQWVZHUHDVVXPHGWRIDLO

RUUHTXLUHIXUWKHUHYDOXDWLRQ 5HIHUHQFH 

 

6WUXFWXUDOFRPSRQHQWVLPSDFWHGE\\DZKLSSLQJSLSHZHUHDVVXPHGWRIDLORU

UHTXLUHIXUWKHUHYDOXDWLRQ 5HIHUHQFH 

,

-HW,PSLQJHPHQW(IIHFWV

)RUHDFKSRVWXODWHGEUHDNWKHHIIHFWVRIMHWLPSLQJHPHQWZHUHHYDOXDWHG7KHFULWHULD

XVHGWRHYDOXDWHWKHVHHIIHFWVZHUHDVIROORZV

 

$OOMHWVZHUHDVVXPHGWREHLQIOXHQFHGE\\JUDYLW\\ 6HFWLRQ5HIHUHQFH 

+RZHYHUEHFDXVHRIWKHMHWIOXLGYHORFLWLHVDQGWKHUHODWLYHSUR[LPLW\\RIWKH

WDUJHWVVWUDLJKWOLQHMHWWUDYHOZDVDVVXPHG

 

-HWVIURPDFLUFXPIHUHQWLDOEUHDNZHUHDVVXPHGWRVZHHSWKHDUFWUDYHOHG

GXULQJWKHZKLS 6HFWLRQ5HIHUHQFH 

 

$ORQJLWXGLQDOEUHDNZDVDVVXPHGWRRFFXUDWDQ\\D]LPXWKORFDWLRQRQWKHSLSH

FLUFXPIHUHQFHZLWKDEUHDNDUHDHTXDOWRWKHHIIHFWLYHFURVVVHFWLRQDOIORZDUHD

LPPHGLDWHO\\XSVWUHDPRIWKHEUHDNORFDWLRQ )RRWQRWHWR&ULWHULRQ

5HIHUHQFH 

 

$MHWGLVFKDUJLQJVDWXUDWHGVWHDPRUDPL[WXUHRIVWHDPDQGZDWHUZLWKDIOXLG

WHPSHUDWXUHJUHDWHUWKDQWKHVDWXUDWLRQWHPSHUDWXUHDWWKHVXUURXQGLQJ

HQYLURQPHQWDOSUHVVXUHZDVDVVXPHGWRH[SDQGLQDKDOIDQJOHFRQH

6HFWLRQ5HIHUHQFHDQGSDJH5HIHUHQFH  1RWH7KLVFULWHULRQ

LVFRQVLVWHQWZLWKWKHSUHYLRXV0RQWLFHOOR+(/%HYDOXDWLRQ5HIHUHQFH 



 %HFDXVHRIWKHXQFHUWDLQWLHVDVVRFLDWHGZLWKEUHDNRULHQWDWLRQDQGMHWJHRPHWU\\DQDGGLWLRQDOGHJUHHRI

FRQVHUYDWLVPZDVHVWDEOLVKHGWRLQFOXGHSRWHQWLDOWDUJHWVEH\\RQGWKHKDOIDQJOHFRQH,QVRPHFDVHVWDUJHWV

XSWRRIIWKHD[LVRIWKHMHWZHUHFRQVLGHUHGKLWDQGLQFDSDEOHRISHUIRUPLQJWKHLUVDIHVKXWGRZQIXQFWLRQ



0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





 

$MHWGLVFKDUJLQJVDWXUDWHGOLTXLGZDWHURUVXEFRROHGZDWHUZDVFKDUDFWHUL]HG

E\\DFRQVWDQWGLDPHWHUMHWIRUSXUSRVHVRIGHWHUPLQLQJWKHMHWIRUFHRQWDUJHWV

)RUWKHSXUSRVHRIGHWHUPLQLQJSRWHQWLDOWDUJHWVVDWXUDWHGOLTXLGZDWHURU

VXEFRROHGZDWHUMHWVZHUHDVVXPHGWRH[SDQGDWOHDVWDWDKDOIDQJOHFRQH

6HFWLRQ5HIHUHQFHDQGSDJH5HIHUHQFH  1RWH7KLVFULWHULRQ

LVPRUHFRQVHUYDWLYHWKDQWKDWXVHGLQWKHSUHYLRXV0RQWLFHOOR+(/%HYDOXDWLRQ

5HIHUHQFHVDQG 

 

7KHPDJQLWXGHRIMHWIRUFHZDVGHWHUPLQHGXVLQJWKHFULWHULDRI,WHP&  RQ

3DJHRI653 5HIHUHQFH 7KHFULWHULDIRUWDNLQJLQWRDFFRXQW

WKHJHRPHWULFFRQVLGHUDWLRQVRIDIOXLGMHWZHUHSURYLGHGLQ$SSHQGL['RI

5HIHUHQFH

 

$SRVWXODWHGMHWZDVFRQVLGHUHGHIIHFWLYHXQWLOLWVWUXFNDVROLGEDUULHUXSRQ

ZKLFKWKHMHWPRPHQWXPLVUHGXFHGWR]HUR$OOVDIHVKXWGRZQFRPSRQHQWV

SLSHVDQGVWUXFWXUHVLPSDFWHGE\\WKHMHWZHUHFRQVLGHUHGLQFDSDEOHRI

SHUIRUPLQJWKHLUVDIHVKXWGRZQIXQFWLRQRUUHTXLUHGIXUWKHUHYDOXDWLRQ

6HFWLRQ5HIHUHQFH 

 

KHUHWKHMHWPXVWWUDYHODVLJQLILFDQWGLVWDQFHWRLPSDFWVDIHVKXWGRZQ

FRPSRQHQWVRUVWUXFWXUHVVLPSOLILHGFDOFXODWLRQVZHUHXVHGWRGHPRQVWUDWH

WKDWWKHMHWLPSLQJHPHQWIRUFHVZHUHQHJOLJLEOH

,

)ORRGLQJ(IIHFWV

,QHDFKDUHDRUFRPSDUWPHQWZKHUHEUHDNVZHUHSRVWXODWHGWKHSRWHQWLDODGYHUVH

HIIHFWVIURPIORRGLQJZHUHLGHQWLILHGXVLQJWKHIROORZLQJFULWHULD 6HFWLRQ

5HIHUHQFH 

D

9XOQHUDELOLW\\RIVDIHVKXWGRZQHTXLSPHQWGXHWRIORRGLQJEHFDXVHRIORFDWLRQ

DQGFRQILJXUDWLRQ

E

3RWHQWLDOUXSWXUHVL]HVDQGWKHDYDLODEOHTXDQWLW\\RIZDWHU

F

$EVHQFHRIIORRUGUDLQVRUGRRUZD\\VZKLFKFRXOGSURYLGHGUDLQDJH

G

([LVWHQFHRIIORRGSURWHFWLRQLQWKHIRUPRIGDPVRUVXPSVZLWKSXPSV

(QYLURQPHQWDOHIIHFWVDUHHYDOXDWHGLQWKH01*3(QYLURQPHQWDO4XDOLILFDWLRQ (4 

SURJUDPEDVHGRQWKHEUHDNFDVHVFRQVLGHUHGLQWKH+(/%DQDO\\VLV%RXQGLQJ

SURILOHVIRUHQYLURQPHQWDOFRQGLWLRQVDUHLGHQWLILHGDQGIORRGLQJHIIHFWVDUHHYDOXDWHG

EDVHGRQWKHVHFRQGLWLRQV

,

(QYLURQPHQWDO(IIHFWVDQG&RPSDUWPHQW3UHVVXUL]DWLRQ

$UHYLHZZDVFRQGXFWHGWRGHWHUPLQHLIWKHVDIHVKXWGRZQFRPSRQHQWVLQ

FRPSDUWPHQWVRUDUHDVLQZKLFKEUHDNVKDYHEHHQSRVWXODWHGDUHTXDOLILHGIRUZRUVW

FDVHHQYLURQPHQWDOFRQGLWLRQVLQFOXGLQJWKHHIIHFWVRIFRPSDUWPHQWSUHVVXUL]DWLRQ

$WWHQWLRQZDVIRFXVHGRQFORVHGFRPSDUWPHQWVZKLFKFRQWDLQHGKLJKHQHUJ\\OLQHV

(QYLURQPHQWDOHIIHFWVDUHHYDOXDWHGLQWKH01*3(QYLURQPHQWDO4XDOLILFDWLRQ (4 

SURJUDPEDVHGRQWKHEUHDNFDVHVFRQVLGHUHGIRUWKH+(/%HYDOXDWLRQV%RXQGLQJ

SURILOHVIRUHQYLURQPHQWDOFRQGLWLRQVDUHLGHQWLILHGLQFOXGLQJFRPSDUWPHQW

SUHVVXUL]DWLRQKHDWXSDQGIORRGLQJHIIHFWV

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

6\\VWHP%UHDN/RFDWLRQV

6\\VWHPEUHDNDQGFULWLFDOFUDFNORFDWLRQVDUHLGHQWLILHGLQ5HIHUHQFHVWKURXJK

,

6DIH6KXWGRZQ5HTXLUHPHQWV5HIHUHQFHDQG

7KHV\\VWHPVUHTXLUHGIRUVDIHVKXWGRZQRIWKHUHDFWRUIRUWKHSRVWXODWHGSLSHIDLOXUHRI

HDFKRIWKHKLJKHQHUJ\\V\\VWHPVZHUHLGHQWLILHGEDVHGRQWKHDQDO\\VHVSUHVHQWHGLQ

86$56HFWLRQ3ODQW(QJLQHHUHG6DIHJXDUGVIRU/2&$DQGWKHRULJLQDO+(/%

$QDO\\VHVRI5HIHUHQFH%\\YHULI\\LQJWKDWWKHVHV\\VWHPVUHPDLQRSHUDWLRQDOLQWKH

HYHQWRIWKHSRVWXODWHGIDLOXUHRIWKHSLSLQJV\\VWHPVLWLVDVVXUHGWKDWWKHSODQWFDQEH

VDIHO\\VKXWGRZQDQGPDLQWDLQHGLQDVDIHVKXWGRZQFRQGLWLRQ

,

6DIH6KXWGRZQ6\\VWHPV

6DIHVKXWGRZQV\\VWHPVDUHVHSDUDWHGLQWRWZRFDWHJRULHVRQHWKRVHQHHGHGIRU

6FUDPPLQJDQG,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQWRGHPRQVWUDWHDGHTXDWHFRUHFRROLQJ

DQGWZRWKRVHQHHGHGIRU3RVW,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQIRU&RQWDLQPHQW

&RROLQJDQG'HFD\\+HDW5HPRYDO

,

6FUDPDQG,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQ3HULRG

7KHIROORZLQJOLVWLGHQWLILHV(PHUJHQF\\&RUH&RROLQJ6\\VWHPV(&&6FUHGLWHGIRU

FRUHFRROLQJ3HU(UUDWDRI5HIHUHQFHZKHUH5HDFWRU3URWHFWLYH$FWXDWLRQKDV

RFFXUUHG VFUDPDQGRUFRQWDLQPHQWJURXSLVRODWLRQ WKHQFRQFXUUHQWZLWKWKH

SRVWXODWHGDFFLGHQWVLQJOHDFWLYHIDLOXUHDQGORVVRIRIIVLWHSRZHULVDVVXPHG

2WKHUZLVHVLQJOHIDLOXUHDQGORVVRIRIIVLWHSRZHULVQRWDVVXPHG

 

5HDFWRU3URWHFWLRQ6\\VWHP 536 &RQWURO5RG'ULYH6\\VWHP &5' DQG

&RQWURO5RGV

 

+LJK3UHVVXUH&RRODQW,QMHFWLRQ +3&, 

 

5HDFWRU3UHVVXUH5HOLHI6DIHW\\5HOLHI9DOYHV 659V 

 

/RZ3UHVVXUH&RRODQW,QMHFWLRQ /3&, 0RGH

 

&RUH6SUD\\ &6 

 

6KXWGRZQ,QVWUXPHQWDWLRQ 6HH,WHP  

 

$X[LOLDU\\6XSSRUW

D 

2QVLWH3RZHUDQG'LVWULEXWLRQ6\\VWHP

E 

(PHUJHQF\\6HUYLFH:DWHU (6: 

F 

(PHUJHQF\\'LHVHO*HQHUDWRU$X[LOLDU\\6\\VWHPV

G 

'&3RZHU6\\VWHPV

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





H 

+HDWLQJ9HQWLODWLRQDQG$LU&RQGLWLRQLQJ +9$& 6\\VWHPV

 

6KXWGRZQ,QVWUXPHQWDWLRQ

7KHPLQLPXPUHTXLUHGSURFHVVLQVWUXPHQWDWLRQWRDVVXUHVDIHVKXWGRZQLVDV

IROORZV

D 

5HDFWRU9HVVHO/HYHO,QGLFDWLRQ

E 

5HDFWRU3UHVVXUH,QGLFDWLRQ

F 

6XSSUHVVLRQ3RRO7HPSHUDWXUH,QGLFDWLRQ

G 

6XSSUHVVLRQ3RRO/HYHO,QGLFDWLRQ

,

3RVW,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQ&RQWDLQPHQW&RROLQJDQG'HFD\\+HDW

5HPRYDO3HULRGV

7KHIROORZLQJOLVWLGHQWLILHVWKRVHV\\VWHPVIRUPLWLJDWLRQDIWHUYHVVHOLVVWDELOL]HG

6LQJOHDFWLYHIDLOXUHLVQRWDVVXPHG/RVVRIRIIVLWHSRZHULVQRWDVVXPHG

 

5+56KXWGRZQ&RROLQJ 6'& 0RGH

 

5+56XSSUHVVLRQ3RRO&RROLQJ 63& 0RGH

 

5+56HUYLFH:DWHU

 

(&&6

 

$OWHUQDWH,QMHFWLRQ6\\VWHPVVXFKDVWKRVHVXJJHVWHGE\\(PHUJHQF\\

2SHUDWLQJ3URFHGXUH&539&RQWURO

 

$OODYDLODEOHWRUXVFRROLQJDVVXJJHVWHGE\\(PHUJHQF\\2SHUDWLQJ3URFHGXUH

&3ULPDU\\&RQWDLQPHQW&RQWURO

,

'HVFULSWLRQRI6DIH6KXWGRZQ3DWKV

6DIHVKXWGRZQFDQEHGHVFULEHGDVVFUDPPLQJDQGLQLWLDOYHVVHOOHYHOVWDELOL]DWLRQ

IROORZHGE\\UHGXFLQJ539SUHVVXUHDQGWHPSHUDWXUHIURPWKHQRUPDORSHUDWLQJ

FRQGLWLRQVRIDSSUR[LPDWHO\\SVLDDQG)WRD539FRRODQWWHPSHUDWXUHRIOHVV

WKDQ)DQGWKH539YHQWHGZLWKWKHUHDFWRULQDVXEFULWLFDOFRQGLWLRQDQGQRIXHO

GDPDJHRUEUHDFKRI3ULPDU\\&RQWDLQPHQW7KHPLQLPXPHTXLSPHQWQHFHVVDU\\IRU

DFKLHYLQJDQGPDLQWDLQLQJVDIHVKXWGRZQLQFOXGHVWKHIROORZLQJ

 

7KH5HDFWRU3URWHFWLRQ6\\VWHPDQG&RQWURO5RG'ULYH6\\VWHP QHJDWLYH

UHDFWLYLW\\IXQFWLRQ 

 

659V 539RYHUSUHVVXUHSURWHFWLRQDQGGHFD\\KHDWUHPRYDOIXQFWLRQV 

 

5+5SXPS /3&,0RGH RU&RUH6SUD\\SXPSDQG5+5SXPSLQ63&

0RGH UHDFWRUYHVVHOOHYHOPDLQWHQDQFHDQGGHFD\\KHDWUHPRYDOIXQFWLRQV 

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





 

5+56HUYLFH:DWHUSXPS GHFD\\KHDWUHPRYDOIXQFWLRQ 

 

(PHUJHQF\\'LHVHO*HQHUDWRU ('* ('*DX[LOLDULHV('*(PHUJHQF\\

6HUYLFH:DWHUSXPS(PHUJHQF\\6HUYLFH:DWHUSXPSDQG'LYLVLRQRI

VDIHW\\UHODWHGSRZHUGLVWULEXWLRQ IRUDOOIXQFWLRQVH[FHSWQHJDWLYHUHDFWLYLW\\ 

 

6KXWGRZQ,QVWUXPHQWDWLRQ IURP5HIHUHQFH 

D 

5HDFWRU9HVVHO/HYHO

E 

5HDFWRU3UHVVXUH

F 

6XSSUHVVLRQ3RRO7HPSHUDWXUH

G 

6XSSUHVVLRQ3RRO/HYHO

 

2IIVLWHSRZHUDQGQRQ(&&6HTXLSPHQWPD\\EHXVHGDVGLUHFWHGE\\WKH

(PHUJHQF\\2SHUDWLQJ3URFHGXUHV&VHULHV

(YDOXDWLRQVSHUIRUPHGWRGHWHUPLQHDFFHSWDEOHSDWKVWRVDIHVKXWGRZQXWLOL]HGWKH

DERYHGHVFULEHGPLQLPXPQHFHVVDU\\HTXLSPHQW

$GGLWLRQDOVDIHVKXWGRZQSDWKVFDQEHGHVFULEHGGHSHQGLQJRQWKHORFDWLRQRIWKH

SRVWXODWHG+(/%DQGWKHVLQJOHDFWLYHIDLOXUHWDNHQ7KH+3&,V\\VWHPFDQEHXVHGWR

PDLQWDLQ539ZDWHUOHYHODQGGHSUHVVXUL]HWKH539VRWKDWWKHORZSUHVVXUHKLJKIORZ

SXPSV 5+5RU&6 FDQEHXVHG7DEOH,LGHQWLILHVWKHV\\VWHPVDYDLODEOHWRVXSSRUW

HDFKVKXWGRZQSHUIRUPDQFHJRDO

)RUDQ\\SRVWXODWHG+(/%ZLWK+3&,DYDLODEOH5&,&LVQRWUHTXLUHGVLQFH+3&,FRXOG

SHUIRUPWKHVDPHIXQFWLRQ)RUDQ\\SRVWXODWHG+(/%ZLWK+3&,QRWDYDLODEOHGXHWRD

VLQJOHDFWLYHIDLOXUHRU+(/%UHODWHGGDPDJHWKHXQLWLVVKXWGRZQXVLQJWKH659V

539GHSUHVVXUL]DWLRQ &RUH6SUD\\ 539ZDWHUOHYHOPDLQWHQDQFH DQG5+5 GHFD\\

KHDWUHPRYDODQG539ZDWHUOHYHOPDLQWHQDQFH 1RVLQJOHDFWLYHIDLOXUHFRXOGDIIHFW

PRUHWKDQ659&6GLYLVLRQRU5+5GLYLVLRQ

7KH5&,&6\\VWHPLVQRWUHTXLUHGIRUDQ\\SRVWXODWHG+(/%LQDQ\\RIWKHLGHQWLILHG

FRPSDUWPHQWV+RZHYHUIRUPRVWSRVWXODWHG+(/%V5&,&LVDYDLODEOHWRVXSSRUWVDIH

VKXWGRZQ

)RUDQ\\SRVWXODWHG+(/%DWOHDVWRQHGLYLVLRQRI(6:LVDYDLODEOHWRSURYLGHFRROLQJWR

RQHGLYLVLRQRI5+5DQG&6V\\VWHPV+HQFHVDIHVKXWGRZQFDQEHDFFRPSOLVKHGIRU

DQ\\SRVWXODWHG+(/%ZLWKRXWUHTXLULQJWKH5&,&6\\VWHPWRVXSSRUWWKHVDIHVKXWGRZQ

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

6DIH6KXWGRZQ6\\VWHP&RPSRQHQW/RFDWLRQV

)RUHDFKRIWKHV\\VWHPVLGHQWLILHGLQ6HFWLRQ,RIWKLVUHSRUWWKHORFDWLRQVRIWKH

PDMRUFRPSRQHQWVPDLQSLSHURXWLQJVDQGSRZHUDQGFRQWUROFDEOHURXWLQJVDUHOLVWHG

LQWKLVVHFWLRQ7KHLQIRUPDWLRQLVSURYLGHGE\\V\\VWHPDQG+(/%DQDO\\VLVYROXPHIRU

UHIHUHQFH

,

5HDFWRU3URWHFWLRQ6\\VWHP

7KH5HDFWRU3URWHFWLRQ6\\VWHP 536 FRQVLVWVRIWKHPRWRUJHQHUDWRUVHWSRZHU

VXSSOLHVWKH536SRZHUGLVWULEXWLRQSDQHOVVHQVRUVDQGFDEOLQJ7KHWZR

PRWRUJHQHUDWRUVHWVDUHORFDWHGLQWKH5HDFWRU%XLOGLQJRQWKHIRRWHOHYDWLRQLQ

9ROXPHVDQG7KH536SRZHUGLVWULEXWLRQSDQHOVDUHORFDWHGLQWKH&DEOH

6SUHDGLQJ5RRP7KHUHDUHVHQVRUV LHKLJKUHDFWRUSUHVVXUHHWF LQFOXGHGLQWKH

SURWHFWLRQV\\VWHPWKDWDUHORFDWHGLQDYDULHW\\RIVLWHVWKURXJKRXWWKHSODQW

,

&RQWURO5RG'ULYH6\\VWHP

7KH&RQWURO5RG'ULYH6\\VWHPFRQVLVWVRIWKHFRQWUROURGVDQGWKHDVVRFLDWHGFRQWURO

URGGULYHK\\GUDXOLFXQLWV7KHHOHFWULFDOVLJQDOVWRWKHVFUDPYDOYHVRQWKHFRQWUROURG

GULYHK\\GUDXOLFXQLWVDUHSURYLGHGE\\WKH5367KHFRQWUROURGVDQG&RQWURO5RG

'ULYHVDUHORFDWHGLQVLGHRIWKH3ULPDU\\&RQWDLQPHQW7KHFRQWUROURGGULYHK\\GUDXOLF

XQLWVDUHORFDWHGLQWZRVHSDUDWHEDQNVRQHLWKHUVLGHRIWKH3ULPDU\\&RQWDLQPHQWRQ

WKHIRRWHOHYDWLRQRIWKH5HDFWRU%XLOGLQJLQ9ROXPHVDQG

,

+LJK3UHVVXUH&RRODQW,QMHFWLRQ +3&, 6\\VWHP

7KH+3&,6\\VWHPFRQVLVWVRIDSXPSZLWKDVWHDPGULYHQWXUELQHDQGDVVRFLDWHG

YDOYLQJ,WLVORFDWHGSULPDULO\\LQWKH+3&,URRP 9ROXPH 7KH+3&,VWHDPVXSSO\\

OLQHDQGWKH+3&,LQMHFWLRQOLQH 36('DQG7:('UHVSHFWLYHO\\ DUH

URXWHGIURPPDLQWKHVWHDPFKDVH 9ROXPH WRWKH+3&,URRP 9ROXPH 7KH

YDOYLQJIRUWKH+3&,6\\VWHPLVORFDWHGLQWKHDERYHLGHQWLILHGFRPSDUWPHQWV3RZHU

FDEOLQJIRUWKH+3&,6\\VWHPLVURXWHGIURPWKHEDWWHULHVLQWKH()7%XLOGLQJLQWRWKH

7XUELQH%XLOGLQJLQWKHHDVWFRUULGRURQWKHIRRWHOHYDWLRQ 9ROXPH 7KH

FDEOHVDUHWKHQURXWHGLQWRWKHFRQGHQVHUED\\ 9ROXPH IURPWKHUHLQWRWKH&5'

SXPSURRP 9ROXPH GRZQWRHTXLSPHQWDQGIORRUGUDLQWDQNDUHD 9ROXPH DQG

ILQDOO\\LQWRWKH+3&,5RRP 9ROXPH 

,

5HDFWRU3UHVVXUH5HOLHI6\\VWHP

7KHHLJKW659VDQGDVVRFLDWHGSLSLQJDUHORFDWHGLQVLGHRIWKH3ULPDU\\&RQWDLQPHQW

RQWKHPDLQVWHDPOLQHV7KHUHDUHIRXUFRQWUROSDQHOVDQGWZRLQVWUXPHQWUDFNV

DVVRFLDWHGZLWKWKH659V7KH659FRQWUROSDQHOLVORFDWHGLQWKH&DEOH6SUHDGLQJ

5RRP7KH659/RZ/RZ6HWFRQWUROSDQHO³$'LVORFDWHGLQWKHFDEOHVSUHDGLQJ

DUHD7KH³%'FRQWUROSDQHOVDUHORFDWHGLQWKHPDLQFRQWUROURRPDQGRQWKHWKLUGIORRU

RIWKH()7%XLOGLQJ7KH659ORZORZVHWLQVWUXPHQWUDFN³$'LVORFDWHGLQWKH

QRUWKHDVWFRUQHURIWKHWRUXVDUHD 9ROXPH DQGWKH³%'UDFNLVORFDWHGRQWKH

IRRWHOHYDWLRQRIWKH5HDFWRU%XLOGLQJQHDUWKHZHVWVLGH&5'K\\GUDXOLFXQLWV

9ROXPH 

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

5HVLGXDO+HDW5HPRYDO 5+5 6\\VWHP

7KH5+56\\VWHPLVDWZRGLYLVLRQDOV\\VWHPZLWKWZRPRWRUGULYHQSXPSVLQHDFK

GLYLVLRQ7KHYDOYLQJIRUWKHV\\VWHPFRQVLVWVRIDVHULHVRIVXFWLRQDQGGLVFKDUJH

YDOYHVZKLFKDOORZWKH5+56\\VWHPWREHRSHUDWHGLQYDULRXVPRGHV7ZRRIWKH

5+5SXPSVDUHORFDWHGLQWKHVRXWKHDVWFRUQHUURRPRIWKH5HDFWRU%XLOGLQJ

9ROXPH DQGWKHRWKHUWZRLQWKHVRXWKZHVWFRUQHUURRPRIWKH5HDFWRU%XLOGLQJ

9ROXPH 7KHVXFWLRQYDOYLQJLVORFDWHGLQWKUHHVHSDUDWHFRPSDUWPHQWV0RVWRI

WKH5+5SXPSGLVFKDUJHYDOYHVDUHDOVRORFDWHGLQWKHFRUQHUURRPVZLWKWKH

IROORZLQJH[FHSWLRQV

 

'LYLVLRQ,VXSSUHVVLRQSRROFRROLQJ 63& YDOYHV 02DQG02 DQG

WKH'LYLVLRQ,,63&YDOYH 02 DUHORFDWHGLQWKHWRUXVDUHD 9ROXPH

 

 

'LYLVLRQ,,63&PRGHRXWERDUGYDOYH 02 LVORFDWHGRQWKHZHVWVLGHRI

5HDFWRU%XLOGLQJDWWKHIRRWHOHYDWLRQLQ9ROXPH

 

7KH'LYLVLRQ,/3&,LQMHFWLRQDQG6'&FRQWDLQPHQWLVRODWLRQYDOYHV 02

DQG02 DQGWKHVKXWGRZQFRROLQJOLQHRXWERDUGLVRODWLRQYDOYH

02 DUHORFDWHGLQ9ROXPHRQWKHIRRWHOHYDWLRQRIWKH5HDFWRU

%XLOGLQJ

 

7KH'LYLVLRQ,,/3&,,QMHFWLRQDQG6'&FRQWDLQPHQWLVRODWLRQYDOYHV 02

DQG02 DUHORFDWHGLQ9ROXPHRQWKHIRRWHOHYDWLRQRIWKH

5HDFWRU%XLOGLQJ

 

7KH'LYLVLRQ,FRQWDLQPHQWVSUD\\LVRODWLRQYDOYHV 02DQG02 DUH

ORFDWHGLQ9ROXPHRQWKHIRRWHOHYDWLRQRIWKH5HDFWRU%XLOGLQJDQGWKH

'LYLVLRQ,,YDOYHV 02DQG02 DUHORFDWHGRQWKHIRRWLQFK

HOHYDWLRQLQ9ROXPHVDQG

7KHSRZHUFDEOLQJIRUWKH5+53XPSVLVURXWHGIURPWKHUHVSHFWLYHVDIHW\\UHODWHG

VZLWFKJHDUURRPLQWKH7XUELQH%XLOGLQJ9ROXPH 'LYLVLRQ, DQG9ROXPH

'LYLVLRQ,, XQGHUJURXQGWRWKH5HDFWRU%XLOGLQJ'LYLVLRQ,FDEOHVDUHWKHQURXWHGWR

5&,&URRP 9ROXPH DQGFRQWLQXHXQGHUJURXQGWRWKHVRXWKHDVWFRUQHUURRP

9ROXPH 7KH'LYLVLRQ,,FDEOHVDUHURXWHGXQGHUJURXQGWRWKH5HDFWRU%XLOGLQJ

GUDLQWDQNURRP 9ROXPH DQGWKHQFRQWLQXHXQGHUJURXQGWRWKHVRXWKZHVWFRUQHU

URRP 9ROXPH 7KHSRZHUFDEOHVWRWKHYDOYHVDUHURXWHGIURPWKHUHVSHFWLYH

0&&VLQWKH7XUELQH%XLOGLQJ9ROXPH 'LYLVLRQ, DQG9ROXPH 'LYLVLRQ,, WRWKH

&DEOH6SUHDGLQJ5RRPDQGLQWRWKH5HDFWRU%XLOGLQJYLD9ROXPH 'LYLVLRQ, DQG

9ROXPH 'LYLVLRQ,, )URPWKHUHWKHFDEOHVDUHURXWHGWRWKHUHVSHFWLYHYDOYHV

7KHFRQWUROFDEOHVIROORZWKHURXWLQJRIWKHYDOYHV¶SRZHUFDEOHV7KHSRZHUDQG

FRQWUROFDEOHVIRU'LYLVLRQ,,5+5YDOYHV0202DQG02DUH

URXWHGIURP0&&V 9ROXPH WRWKHWKLUGIORRU()7%XLOGLQJ7KH\\WKHQJR

XQGHUJURXQGDURXQGWKHVRXWKVLGHRIWKH5HDFWRU%XLOGLQJWRWKHIRRWHOHYDWLRQ

9ROXPH RIWKH5HDFWRU%XLOGLQJDQGWKHQWRWKHUHVSHFWLYHYDOYHV

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

&RUH6SUD\\ &6 6\\VWHP

7KH&RUH6SUD\\6\\VWHPLVDWZRGLYLVLRQDOV\\VWHPFDSDEOHRIWDNLQJVXSSUHVVLRQSRRO

ZDWHUDQGVSUD\\LQJLWRYHUWKHWRSRIWKHUHDFWRUFRUH(DFKGLYLVLRQKDVDFRUHVSUD\\

SXPSDYDOYHRQWKHVXFWLRQOLQHWRWKHVXSSUHVVLRQFKDPEHUDQGLQERDUGDQG

RXWERDUGLQMHFWLRQYDOYHV

7KH'LYLVLRQ,SXPS 3$ LVORFDWHGLQWKHVRXWKHDVWFRUQHUURRPRIWKH5HDFWRU

%XLOGLQJ 9ROXPH LQWKHVDPHURRPZLWKWKH'LYLVLRQ,5+5SXPSV,WVVXFWLRQOLQH

7:+( LVURXWHGIURPWKHVXSSUHVVLRQFKDPEHUDUHD 9ROXPH WRWKH&6

SXPS7KHSRROVXFWLRQYDOYH 02 LVORFDWHGLQWKHVRXWKHDVWFRUQHUURRP

9ROXPH ZLWKWKH&6SXPS7KHGLVFKDUJHSLSLQJLVURXWHGIURPWKHVRXWKHDVW

FRUQHUURRPXSWKURXJKWKHHDVWVLGHRIWKHIRRWHOHYDWLRQRIWKH5HDFWRU

%XLOGLQJ 9ROXPH DQGILQDOO\\XSWRWKHIRRWLQFKHOHYDWLRQRIWKH5HDFWRU

%XLOGLQJRQWKHHDVWVLGH 9ROXPH 7KHLQERDUGDQGRXWERDUGLQMHFWLRQYDOYHV

02DQG02UHVSHFWLYHO\\ DUHORFDWHGLQWKLVDUHD 9ROXPH 

7KH'LYLVLRQ,,&RUH6SUD\\6\\VWHPLVORFDWHGRQWKHZHVWVLGHRIWKH5HDFWRU%XLOGLQJ

7KH'LYLVLRQ,,FRUHVSUD\\SXPS 3% DQGWKHSRROVXFWLRQYDOYH 02 DUH

ORFDWHGLQWKHVRXWKZHVWFRUQHUURRP 9ROXPH 7KH&6SXPSVXFWLRQSLSLQJLV

URXWHGIURPWKHVXSSUHVVLRQFKDPEHUDUHD 9ROXPH WRWKHVRXWKZHVWFRUQHU

URRP7KHSXPSGLVFKDUJHSLSLQJLVURXWHGIURPWKHVRXWKZHVWFRUQHUURRPXS

WKURXJKWKHIRRWHOHYDWLRQRIWKH5HDFWRU%XLOGLQJ 9ROXPH DQGXSWRWKH

IRRWLQFKHOHYDWLRQRIWKH5HDFWRU%XLOGLQJ 9ROXPH 7KHLQERDUGDQG

RXWERDUGLQMHFWLRQYDOYHV 02DQG02UHVSHFWLYHO\\ DUHORFDWHGRQWKH

ZHVWVLGHRIWKH5HDFWRU%XLOGLQJDWWKHIRRWLQFKHOHYDWLRQLQ9ROXPH

7KHFDEOLQJIRUHDFKGLYLVLRQRIWKH&RUH6SUD\\6\\VWHPIROORZVWKHVDPHURXWLQJDV

WKHFRUUHVSRQGLQJGLYLVLRQRI5+5

,

5+56HUYLFH:DWHU6\\VWHP

7KH5+56HUYLFH:DWHU 5+56: 6\\VWHPVXSSOLHVZDWHUIURPWKHXOWLPDWHKHDWVLQN

ULYHU WRWKHWXEHVLGHRIWKH5+5KHDWH[FKDQJHUVDQGEDFNWRWKHULYHU7KHV\\VWHP

KDVSXPSVZLWKGHGLFDWHGWRHDFKGLYLVLRQ7KHSXPSVIRUERWKGLYLVLRQVDUH

ORFDWHGLQWKH,QWDNH6WUXFWXUHSXPSURRP 9ROXPH 7KHGLVFKDUJHSLSLQJLV

URXWHGIURPWKH,QWDNH6WUXFWXUH 9ROXPH WKURXJKWKHDFFHVVWXQQHO 9ROXPH 

LQWRWKH7XUELQH%XLOGLQJQRUWKFRUULGRU 9ROXPH )URPWKH7XUELQH%XLOGLQJQRUWK

FRUULGRUWKH\\DUHURXWHGDERYHWKHIRRWHOHYDWLRQRIWKH7XUELQH%XLOGLQJWKURXJK

9ROXPHVDQGDQGLQWRWKHFRQGHQVHUED\\DUHD 9ROXPH 7KHOLQHVH[LWWKH

7XUELQH%XLOGLQJIURPWKHFRQGHQVHUED\\DQGSHQHWUDWHWKH5HDFWRU%XLOGLQJLQWKH

7,3GULYHURRP9ROXPH)URPWKH7,3GULYHURRPWKHOLQHVDUHURXWHGWRWKHWRUXV

DUHD 9ROXPHV DQGWKHQWRWKHUHVSHFWLYHFRUQHUURRPV

$X[LOLDU\\DLUFRPSUHVVRUVDUHORFDWHGRQWKHIRRWHOHYDWLRQRIWKH5HDFWRU

%XLOGLQJ'LYLVLRQ,LQ9ROXPHDQG'LYLVLRQ,,LQ9ROXPH(DFKGLYLVLRQV¶KHDW

H[FKDQJHUGLVFKDUJHSUHVVXUHFRQWUROYDOYHV &9DQG&9 DUHDOVR

ORFDWHGLQWKHUHVSHFWLYHFRUQHUURRPV

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





&DEOLQJIRUWKHV\\VWHPLVURXWHGHQWLUHO\\ZLWKLQWKH7XUELQH%XLOGLQJ7KHSRZHU

FDEOLQJIRUWKHSXPSVLVURXWHGIURPWKHUHVSHFWLYHVZLWFKJHDUDUHDV 9ROXPHVDQG

 WRWKH,QWDNH6WUXFWXUH 9ROXPH &RQWUROFDEOLQJLVURXWHGWRWKH&RQWURO5RRP

YLDWKHUHVSHFWLYHGLYLVLRQDOURXWLQJLQWKH7XUELQH%XLOGLQJ)RU'LYLVLRQ,WKLVZRXOG

EHIURPWKHFDEOHVSUHDGLQJURRPWR9ROXPHVDQG)RU'LYLVLRQ,,WKLV

ZRXOGEHIURPWKHFDEOHVSUHDGLQJURRPWR9ROXPHDQGWKHQLQWRWKHVZLWFKJHDU

DUHD

,

5HDFWRU&RUH,VRODWLRQ&RROLQJ 5&,& 6\\VWHP

KLOHQRWUHTXLUHGIRUVDIHVKXWGRZQWKH5&,&6\\VWHPPD\\EHXVHGLIDYDLODEOH$

GHVFULSWLRQLVLQFOXGHGLQWKLVVHFWLRQIRUFRPSOHWHQHVV

7KH5&,&6\\VWHPOLNHWKH+3&,6\\VWHPFRQVLVWVRIDVWHDPGULYHQWXUELQHSXPS

DVVHPEO\\DQGDVVRFLDWHGYDOYLQJ7KHWXUELQHSXPSDQGPRVWRIWKHDVVRFLDWHG

YDOYHVDUHORFDWHGLQ5&,&URRP 9ROXPH 7KHVWHDPVXSSO\\OLQH 36(' 

DQGWKH5&,&LQMHFWLRQOLQH ):(' DUHURXWHGIURPWKH5&,&URRPWKURXJKWKH

WRUXVDUHD 9ROXPH DQGXSLQWRPDLQVWHDPFKDVH 9ROXPH 7KHYDOYLQJIRUWKH

5&,&6\\VWHPLVORFDWHGLQHLWKHUWKH5&,&URRPRUPDLQVWHDPFKDVH7KH5&,&

SRZHUFDEOHVDUHURXWHGIURPWKHEDWWHULHVLQWKH3ODQW$GPLQLVWUDWLRQ%XLOGLQJ

WKURXJKWKH&DEOH6SUHDGLQJ5RRPLQWR7,3GULYHURRP 9ROXPH LQWKH5HDFWRU

%XLOGLQJDQGGRZQWRWKH5&,&URRP 9ROXPH 

,

6KXWGRZQ,QVWUXPHQWDWLRQ

7KH6KXWGRZQ,QVWUXPHQWDWLRQOLNHWKHRWKHUVDIHW\\UHODWHGHTXLSPHQWLV

GLYLVLRQDOL]HG7KHORFDWLRQVIRUWKHFRPSRQHQWVIRUHDFKGLYLVLRQDUHJLYHQEHORZ



'LYLVLRQ

3DUDPHWHU

0HDVXUHG

(TXLSPHQW

'HVLJQDWLRQ

&RPSDUWPHQW

,

5HDFWRU:DWHU/HYHO

/7$

(DVWVLGHRI5HDFWRU

%OGJ(OHYIRRW

,

6XSSUHVVLRQ3RRO/HYHO /7$

7RUXV$UHD

,

5HDFWRU3UHVVXUH

37$

(DVWVLGHRI5HDFWRU

%OGJ(OHYIRRW

LQFK

,

6XSSUHVVLRQ3RRO

7HPSHUDWXUH

7($WR$

7RUXV$UHD

,,

5HDFWRU:DWHU/HYHO

/7%

HVWVLGHRI5HDFWRU

%OGJ(OHYIRRW

,,

6XSSUHVVLRQ3RRO/HYHO /7%

7RUXV$UHD

,,

5HDFWRU3UHVVXUH

37%

HVWVLGHRI5HDFWRU

%OGJ(OHYIRRW

LQFK

,,

6XSSUHVVLRQ3RRO

7HPSHUDWXUH

7(%WR%

7RUXV$UHD

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7KHFDEOLQJIURPWKHVHLQVWUXPHQWVLVURXWHGWKURXJKWKHVDPHURXWLQJVFKHPHVEDFN

WRWKHFDEOHVSUHDGLQJDUHDDVDUHWKHRWKHUVDIHW\\UHODWHGGLYLVLRQDOVHSDUDWHG

FDEOHV7KHRQO\\H[FHSWLRQVDUHWKH'LYLVLRQ,,VXSSUHVVLRQSRROWHPSHUDWXUHFDEOHV

DQG$OWHUQDWH6KXWGRZQ6\\VWHP $6'6 LQVWUXPHQWV)URPWKHWRUXVDUHDWKH\\DUH

URXWHGLQWRWKHFRQGHQVHUED\\ 9ROXPH DQGWKURXJK9ROXPHRQWKHIRRW

HOHYDWLRQRIWKH7XUELQH%XLOGLQJDQGLQWRWKH(PHUJHQF\\)LOWUDWLRQ%XLOGLQJIURP

WKHUH$6'6LQVWUXPHQWVWKDWKDYHEHHQUHURXWHGDUHUHDFWRUZDWHUOHYHO

/7%DQGVXSSUHVVLRQSRROOHYHO/7%7KHURXWLQJLVXQGHUJURXQG

DURXQGWKHVRXWKVLGHRIWKH5HDFWRU%XLOGLQJWRWKHWKLUGIORRU()7

,

(PHUJHQF\\6HUYLFH:DWHU6\\VWHPV

7KHWZRHPHUJHQF\\VHUYLFHZDWHUV\\VWHPVFRQVLVWLQJRIWKH(PHUJHQF\\'LHVHO

  • HQHUDWRU(PHUJHQF\\6HUYLFH:DWHU ('*(6: 6\\VWHPDQGWKH(PHUJHQF\\

)LOWUDWLRQ7UDLQ(PHUJHQF\\6HUYLFH:DWHU ()7(6: 6\\VWHPDUHERWKWZR

GLYLVLRQDOV\\VWHPVZKLFKFROOHFWLYHO\\VXSSO\\FRROLQJZDWHUWRWKHHPHUJHQF\\GLHVHO

JHQHUDWRUVWKH(&&6SXPSURRPFRROHUVWKH5+5 &RUH6SUD\\SXPSVDQGWKH

()76\\VWHP7KHV\\VWHPVZKHQFRPELQHGFRQVLVWRISXPSV3$%& '

ORFDWHGLQWKH,QWDNH6WUXFWXUH 9ROXPH 3XPSV3$DQG3&DUHERWK

'LYLVLRQ,FRPSRQHQWVDQGSXPSV3%DQG3'DUHERWK'LYLVLRQ,,

FRPSRQHQWV

,

(PHUJHQF\\'LHVHO*HQHUDWRU(PHUJHQF\\6HUYLFH:DWHU6\\VWHP

3XPS3$DQG3%DUHXVHGWRVXSSO\\FRROLQJZDWHUWRWKH'LYLVLRQ,DQG

'LYLVLRQ,,HPHUJHQF\\GLHVHOJHQHUDWRUUHVSHFWLYHO\\7KHGLVFKDUJHSLSLQJIURP

HDFK('*(6:SXPSWHHVLQWKHLQWDNHVWUXFWXUHZLWKVHSDUDWHLQFKOLQHVURXWHG

XQGHUJURXQGWRWKHUHVSHFWLYH('*7KHRWKHUEUDQFKRIWKHWHHRQHDFKOLQHKDVD

FORVHGPDQXDOYDOYHLQWKH,QWDNH6WUXFWXUH (6:DQG(6: 7KH

FRROLQJZDWHUOLQHVWRWKH('*VDUHFURVVWLHGLQWKH,QWDNH6WUXFWXUH7KLVDOORZV

FRROLQJRIHLWKHU('*IURPSXPS3$RU3%

7KHSRZHUFDEOHIRU'LYLVLRQ,(6:SXPS3$LVURXWHGIURP0&&LQWKH

()7%XLOGLQJLQWRWKHPDLQIHHGSXPSDUHD 9ROXPH DORQJWKHHDVWFRUULGRUDW

WKHIRRWHOHYDWLRQ 9ROXPH DORQJWKHQRUWK7XUELQH%XLOGLQJFRUULGRU

9ROXPH WKURXJKWKHDFFHVVWXQQHO 9ROXPH DQGLQWRWKHLQWDNHVWUXFWXUH$

FRQWUROFDEOHIRU3$LVURXWHGIURPWKH&RQWURO5RRPWKURXJKWKH&DEOH

6SUHDGLQJ5RRPWKURXJK9ROXPHLQWRWKHPDLQIHHGSXPSDUHD 9ROXPH 

DQGLQWRWKH()7%XLOGLQJ$QRWKHUFRQWUROFDEOHIRU3$LVURXWHGIURP&LQ

WKH&RQWURO5RRPWKURXJKWKH&DEOH6SUHDGLQJ5RRPWKURXJK9ROXPHLQWR

WKHPDLQIHHGSXPSDUHD 9ROXPH DORQJWKHHDVWFRUULGRUDWWKHIRRW

HOHYDWLRQDORQJWKHQRUWK7XUELQH%XLOGLQJFRUULGRU 9ROXPH DQGLQWRWKH

'LYLVLRQ,HVVHQWLDOVZLWFKJHDUDUHD 9ROXPH EHIRUHHQWHULQJWKH'LYLVLRQ,('*

FRPSDUWPHQW 9ROXPH 

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7KHSRZHUFDEOHIRU'LYLVLRQ,,(6:SXPS3%LVURXWHGIURP0&&

ORFDWHGLQWKHVRXWKHDVWFRUQHURIWKH7XUELQH%XLOGLQJRQHOHYDWLRQIRRW

9ROXPH DORQJWKHHDVWFRUULGRURIWKH7XUELQH%XLOGLQJ 9ROXPH DORQJWKH

QRUWK7XUELQH%XLOGLQJFRUULGRU 9ROXPH DQGLQWRWKH'LYLVLRQ,,HVVHQWLDO

VZLWFKJHDUDUHD 9ROXPH EHIRUHHQWHULQJWKH,QWDNH6WUXFWXUHWKURXJKDQ

XQGHUJURXQGGXFWEDQN7KHFRQWUROFDEOHVIRU3%RULJLQDWHLQWKH()7

%XLOGLQJDQGDUHURXWHGLQWRWKH7XUELQH%XLOGLQJVRXWKHDVWFRUQHUDWHOHYDWLRQ

IRRW)URPWKHUHRQHRIWKHFRQWUROFDEOHVLVURXWHGGLUHFWO\\LQWRWKH&RQWURO

5RRPRQHLVURXWHGWR0&& ZKLFKLVORFDWHGLQ9ROXPH DQGRQHLV

URXWHGDORQJWKHHDVW7XUELQH%XLOGLQJFRUULGRUDWWKHIRRWHOHYDWLRQ

9ROXPH DORQJWKHQRUWK7XUELQH%XLOGLQJFRUULGRU 9ROXPH DQGLQWRWKH

'LYLVLRQ,,HVVHQWLDOVZLWFKJHDUDUHD 9ROXPH EHIRUHHQWHULQJWKH'LYLVLRQ,,

(PHUJHQF\\'LHVHO*HQHUDWRUFRPSDUWPHQW 9ROXPH 

,

(PHUJHQF\\)LOWUDWLRQ7UDLQ(PHUJHQF\\6HUYLFH:DWHU6\\VWHP

3XPSV3& 'VXSSO\\FRROLQJZDWHUWRWKHUHVSHFWLYH'LYLVLRQ,DQG,,(&&6

SXPSURRPFRROHUVWKH5+5DQG&RUH6SUD\\SXPSVDQGWKH()76\\VWHP7KH

'LYLVLRQ,(6:/LQHWR(&&6URRPFRROHUVDQG'LYLVLRQ,5+5DQG&RUH6SUD\\

3XPSV (6:+) LVURXWHGIURPWKH,QWDNH6WUXFWXUHWKURXJKWKHDFFHVV

WXQQHO 9ROXPH LQWRWKH7XUELQH%XLOGLQJQRUWKFRUULGRURQWKHIRRW

HOHYDWLRQ 9ROXPH )URPWKHUHLWLVURXWHGLQWKHQRUWKFRUULGRURYHULQWRWKH

UHDFWRUIHHGSXPSDUHD 9ROXPH :LWKLQWKLVFRPSDUWPHQWWKHOLQHVWHHDJDLQ

5HIHUHQFH ZLWKWKHSLSLQJOLQH(6:+%'URXWHGLQWRWKH(PHUJHQF\\

)LOWUDWLRQ%XLOGLQJ7KHOLQHWRWKH(&&6SXPSURRPFRROHUVDQG5+5DQG&RUH

6SUD\\3XPSV6:$+)LVURXWHGIURPWKHPDLQIHHGSXPSDUHDLQWRWKH

FRQGHQVHUED\\DUHD 9ROXPH RQWKHIRRWHOHYDWLRQ7KHSLSHLVURXWHG

DORQJWKHHDVWZDOORYHUWRWKHVRXWKZDOORIWKHURRP7KHSLSLQJOLQHH[LWVWKH

FRQGHQVHUED\\WKURXJKWKHVRXWKZDOODQGLQWRWKH5HDFWRU%XLOGLQJ7KLVOLQH

HQWHUVWKH5HDFWRU%XLOGLQJLQWKH7,3GULYHURRP 9ROXPH DQGLVURXWHGIURP

WKHUHLQWRWKHWRUXVDUHD 9ROXPH 2QFHLQWKHWRUXVDUHDWKHOLQHWHHVDJDLQZLWK

SDUWRIWKHIORZURXWHGWRWKHVRXWKHDVWFRUQHUURRP 9ROXPH DQGWKHUHPDLQGHU

WRWKH+3&,URRP 9ROXPH IRUWKH'LYLVLRQ,+3&,URRPFRROHU

7KH'LYLVLRQ,,(6:/LQHWRWKH(&&6URRPFRROHUV (6:+) IROORZVD

SDUDOOHOURXWHWRLWV'LYLVLRQ,FRXQWHUSDUWWRWKHQRUWKWXUELQHFRUULGRUDWWKH

IRRWHOHYDWLRQ 9ROXPH )URPWKHUHLWLVURXWHGWR9ROXPHRQWKHIRRW

HOHYDWLRQRIWKH7XUELQH%XLOGLQJ,Q9ROXPHWKHOLQHWHHV 5HIHUHQFH ZLWK

OLQH6:%+)URXWHGLQWR9ROXPHDQGWKHQLQWRWKHFRQGHQVHUED\\

9ROXPH )URPWKHFRQGHQVHUED\\WKHOLQHHQWHUVWKH5HDFWRU%XLOGLQJLQWKH

PDLQVWHDPFKDVH 9ROXPH DQGIURPWKHUHLVURXWHGLQWRWKHWRUXVDUHD

9ROXPH $IWHUHQWHULQJWKHWRUXVDUHDWKHOLQHWHHVDJDLQZLWKSDUWRIWKHIORZ

JRLQJWRWKHVRXWKZHVWFRUQHUURRP 9ROXPH DQGWKHUHPDLQGHUWRWKH'LYLVLRQ,,

+3&,URRPFRROHULQWKH+3&,URRP 9ROXPH 

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7KHFDEOHIRUWKHRWKHUWZR(6:SXPSV 3&DQG3' EHJLQVLQWKH()7

%XLOGLQJ7KHSRZHUFDEOHWR3&LVURXWHGIURP0&&LQWKH()7%XLOGLQJ

LQWRWKHPDLQIHHGSXPSDUHD9ROXPHDORQJWKHHDVWFRUULGRUDWWKHIRRW

HOHYDWLRQDQGWKHQDORQJWKHQRUWK7XUELQH%XLOGLQJFRUULGRU9ROXPHLQWRWKH

DFFHVVWXQQHO2QHFRQWUROFDEOHLVORFDWHGHQWLUHO\\LQWKH()7%XLOGLQJ7KHRWKHU

HQWHUVWKH7XUELQH%XLOGLQJLQWKHPDLQIHHGSXPSDUHDWKHQLVURXWHGLQWR

9ROXPHDQGLQWRWKH&DEOH6SUHDGLQJ5RRPEHIRUHHQWHULQJWKH&RQWURO

5RRP)RUSXPS3'WKHSRZHUFDEOHLVURXWHGIURP0&&LQWKH()7

%XLOGLQJLQWRWKH7XUELQH%XLOGLQJVRXWKHDVWFRUQHURQWKHIRRWHOHYDWLRQ,WLV

WKHQURXWHGDORQJWKHHDVWFRUULGRUDWWKDWHOHYDWLRQLQWRWKH'LYLVLRQ,,FDEOHZD\\

9ROXPH DQGHQGLQJLQ'LYLVLRQ,,HVVHQWLDOVZLWFKJHDUDUHD9ROXPH)URP

WKHUHWKHFDEOHLVURXWHGRXWVLGHXQGHUJURXQGWRWKH,QWDNH6WUXFWXUH7KUHH

FRQWUROFDEOHVIRUWKLVSXPSDUHORFDWHGHQWLUHO\\ZLWKLQWKH()7%XLOGLQJDQGWKH

RWKHUHQWHUVWKH7XUELQH%XLOGLQJDWWKHIRRWHOHYDWLRQLQ9ROXPH)URP

WKHUHLWLVURXWHGXSWRWKHWXUELQHRSHUDWLQJIORRUEHIRUHHQWHULQJWKH&RQWURO5RRP

,

(PHUJHQF\\'LHVHO*HQHUDWRUVDQG$X[LOLDULHV

7KHUHLVRQH(PHUJHQF\\'LHVHO*HQHUDWRU ('* IRUHDFKHVVHQWLDOGLYLVLRQDW

0RQWLFHOOR7KH('*VDUHORFDWHGLQDGMDFHQWFRPSDUWPHQWVZLWK('*ORFDWHGLQ

9ROXPHDQG('*ORFDWHGLQ9ROXPH7KHORFDOFRQWUROSDQHOVDQGDLUVWDUW

V\\VWHPVDUHDOVRORFDWHGLQWKHUHVSHFWLYHFRPSDUWPHQWZLWKWKH('*7KHRLOGD\\

WDQNVDUHORFDWHGQH[WWR9ROXPHLQVHSDUDWHGD\\WDQNURRPV&DEOLQJIRUSRZHUWR

WKHORFDOFRQWURODQGHOHFWULFDOFDELQHWVLVURXWHGLQWKHVDPHPDQQHUDVWKHFRQWURO

FDEOHVIRU5+56:SXPSV7KH('*SRZHUFDEOLQJLVURXWHGWRWKHUHVSHFWLYH

HVVHQWLDOVZLWFKJHDUZKLFKDUHLQDGMDFHQWFRPSDUWPHQWVLQWKH7XUELQH%XLOGLQJ

,

$X[LOLDU\\3RZHU'LVWULEXWLRQ6\\VWHPV

7KH$X[LOLDU\\3RZHU'LVWULEXWLRQ6\\VWHPFRQVLVWVRIWKH.9VZLWFKJHDUWKH9DF

ORDGFHQWHUPRWRUFRQWUROFHQWHUVDQGWKHWUDQVIRUPHUVEHWZHHQWKHP7KHV\\VWHPLV

FDSDEOHRIGLVWULEXWLQJWKHHOHFWULFDOSRZHUJHQHUDWHGE\\WKH('*VXQGHUDORVVRI

RIIVLWHSRZHUFRQGLWLRQ)RU'LYLVLRQ,ERWKWKH.9VZLWFKJHDUDQG9DF

GLVWULEXWLRQHTXLSPHQWDUHORFDWHGLQ9ROXPHRQWKHIRRWHOHYDWLRQRIWKH

7XUELQH%XLOGLQJLQWKHQRUWKZHVWFRUQHU7KH'LYLVLRQ,,ORDGFHQWHUVDUHORFDWHG

GLUHFWO\\DERYHWKH'LYLVLRQ,ORDGFHQWHUVRQWKHQH[WIORRU IRRWHOHYDWLRQ LQ

9ROXPH(VVHQWLDO0&&V$$DQG$DUHORFDWHGLQWKHVRXWKHDVW

FRUQHURIWKH7XUELQH%XLOGLQJZLWK'LYLVLRQ,0&&$ORFDWHGRQWKHIRRW

HOHYDWLRQLQ9ROXPHDQG'LYLVLRQ,,0&&V$DQG$ORFDWHGRQWKHIRRW

HOHYDWLRQLQ9ROXPH(VVHQWLDO0&&VDQGDUHORFDWHGLQWKH()77KH

()7LVQRWDVVLJQHGDYROXPHQXPEHUEHFDXVHWKHUHDUHQRKLJKHQHUJ\\OLQHVZLWKLQ

WKHEXLOGLQJ

&DEOLQJIURPORDGFHQWHUVWRWKH0&&VLVURXWHGLQVHSDUDWHFRPSDUWPHQWV&DEOHV

IURP'LYLVLRQ,ORDGFHQWHUVDUHURXWHGIURP9ROXPHWKURXJK9ROXPHVDQG

WHUPLQDWLQJLQ9ROXPH2WKHU'LYLVLRQ,FDEOHVQRWWHUPLQDWLQJDWWKH0&&DUH

URXWHGXSLQWR9ROXPHDQGLQWRWKHFDEOHVSUHDGLQJDUHD7KH'LYLVLRQ,,FDEOHV

DUHURXWHGIURPWKHORDGFHQWHUV9ROXPHWKURXJK9ROXPHVDQGDQG

WHUPLQDWLQJLQ9ROXPH&DEOHVJRLQJWRWKHFDEOHVSUHDGLQJDUHDDUHURXWHG

WKURXJK9ROXPH

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

'&3RZHU6\\VWHPV

LWKWKHH[FHSWLRQRIWKH9GFGLVWULEXWLRQSDQHOVORFDWHGLQWKH.9VZLWFKJHDU

URRPVWKHPDMRU'&SRZHUFRPSRQHQWVUHTXLUHGIRUVDIHVKXWGRZQDUHORFDWHGLQ

WKHEDWWHU\\URRPVRIWKH$GPLQLVWUDWLRQRU(PHUJHQF\\)LOWUDWLRQ%XLOGLQJV7KH

FDEOLQJLVURXWHGIURP&DEOH6SUHDGLQJ5RRPWRWKHUHVSHFWLYHFRPSRQHQWVDORQJ

WKHGLYLVLRQDOURXWLQJVGHVFULEHGSUHYLRXVO\\7KHRQO\\H[FHSWLRQLVWKH+3&,SRZHU

FDEOHVZKLFKDUHURXWHGLQDVLPLODUURXWHWRWKH'LYLVLRQ,,6327026FDEOHV

+RZHYHURQFHURXWHGLQWRWKH5HDFWRU%XLOGLQJWKH+3&,FDEOHVDUHWKHQURXWHGWR

WKH+3&,DUHD 9ROXPH 

,

+9$&6\\VWHPV

7KHRQO\\+9$&(TXLSPHQWUHTXLUHGIRUVDIHVKXWGRZQDUHWKH(&&65RRP&RROHUV

9$& 'LYLVLRQ, DQG9$& 'LYLVLRQ,, ORFDWHGLQUHVSHFWLYH5HDFWRU%XLOGLQJ

FRUQHUURRPVRQWKHIRRWHOHYDWLRQDQGWKH('*VXSSO\\IDQ96)IRU('*1R

DQG96)IRU('*1R7KHFRROLQJZDWHUIRUWKH(&&6URRPFRROHUVLV

VXSSOLHGIURPWKHUHVSHFWLYH(PHUJHQF\\6HUYLFH:DWHU6\\VWHPSXPSZLWK9$&

VXSSOLHGE\\3&DQG9$&E\\3'3RZHUFDEOLQJIRUWKH9$&DQG

9$&LVURXWHGLQWRWKH5HDFWRU%XLOGLQJIURPWKHFDEOHVSUHDGLQJDUHDLQWKHVDPH

PDQQHUDVWKHRWKHUGLYLVLRQDOFDEOHV

7KHSRZHUDQGFRQWUROFDEOHVIRU'LYLVLRQ,('*VXSSO\\IDQ 96) DUHURXWHGIURP

0&&LQWKH()7%XLOGLQJLQWRWKHPDLQIHHGSXPSDUHD 9ROXPH DORQJWKH

HDVWFRUULGRUDWWKHIRRWHOHYDWLRQ 9ROXPH DORQJWKHQRUWK7XUELQH%XLOGLQJ

FRUULGRU 9ROXPH DQGLQWR'LYLVLRQ,VZLWFKJHDUDUHD 9ROXPH EHIRUHHQWHULQJ

WKH'LYLVLRQ,('*FRPSDUWPHQW 9ROXPH 

7KHSRZHUDQGFRQWUROFDEOHVIRU'LYLVLRQ,,('*VXSSO\\IDQ 96) DUHURXWHGIURP

0&&ORFDWHGLQWKHVRXWKHDVWFRUQHURIWKH7XUELQH%XLOGLQJDWWKHIRRW

HOHYDWLRQDORQJWKHHDVWFRUULGRURIWKH7XUELQH%XLOGLQJDWWKHIRRWHOHYDWLRQ

DORQJWKHQRUWK7XUELQH%XLOGLQJFRUULGRUDQGLQWRWKH'LYLVLRQ,,HVVHQWLDOVZLWFKJHDU

DUHD 9ROXPH EHIRUHHQWHULQJWKH'LYLVLRQ,,('*FRPSDUWPHQW 9ROXPH 



0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,

6DIH6KXWGRZQ&RPSRQHQWV$YDLODEOH



6$)(6+87'2:1&20321(176$9$,/$%/()25($&+3(5)250$1&(*2$/  

'LYLVLRQ

(TXLSPHQW5HTXLUHGWR

$FKLHYHDQG0DLQWDLQ

6XEFULWLFDOLW\\

(TXLSPHQW5HTXLUHGWR

0DLQWDLQ539,QYHQWRU\\  

(TXLSPHQW5HTXLUHGIRU

539'HSUHVVXUL]DWLRQ

(TXLSPHQW5HTXLUHGWR5HPRYH'HFD\\

+HDWDQGFRQWDLQPHQWVSUD\\FRROLQJ

,

5HDFWRU3URWHFWLRQ6\\VWHPDQG

&RQWURO5RGVDQG&RQWURO5RG

'ULYHV

&63XPSDQG5+53XPSV

$YDLODEOH  

x &63XPSRU5+53XPS

/3&,0RGH   

659V$YDLODEOH  

x 659V1HHGHGIRU/3&,

539,QYHQWRU\\5HFRYHU\\RU

x 659V1HHGHGIRU&63XPS

539,QYHQWRU\\5HFRYHU\\

659V5+53XPSV&63XPS5+5

+HDW([FKDQJHUDQG5+56:3XPSV

$YDLODEOH

x 5+53XPS 6'&0RGH 5+5+HDW

([FKDQJHUDQG5+56:3XPS1HHGHG

RU

x &63XPS6595+53XPS 63&

0RGH 5+5+HDW([FKDQJHUDQG

5+56:3XPS1HHGHGRU

x 5+53XPS /3&,0RGH 5+5+HDW

([FKDQJHU659DQG5+56:3XPS

1HHGHG

,,

5HDFWRU3URWHFWLRQ6\\VWHPDQG

&RQWURO5RGVDQG&RQWURO5RG

'ULYHV

+3&,&63XPSDQG5+5

3XPSV$YDLODEOH

x +3&,&63XPSRU5+5

3XPS /3&,0RGH 1HHGHG

RU

x &63XPSRU5+53XPS

/3&,0RGH   

+3&,DQG659V$YDLODEOH

x +3&,DQG6591HHGHG

RU

x 659V1HHGHGIRU/3&,

539,QYHQWRU\\5HFRYHU\\RU

x 659V1HHGHGIRU&63XPS

539,QYHQWRU\\5HFRYHU\\

659V5+53XPS&63XPS5+5

+HDW([FKDQJHUDQG5+56:3XPSV

$YDLODEOH

x 5+53XPS 6'&0RGH 5+5+HDW

([FKDQJHUDQG5+56:3XPS1HHGHG

RU

x &63XPS6595+53XPS 63&

0RGH 5+5+HDW([FKDQJHUDQG

5+56:3XPS1HHGHGRU

x 5+53XPS /3&,0RGH 6595+5

+HDW([FKDQJHUDQG5+56:3XPS

1HHGHG





5HTXLUHG$X[LOLDU\\6XSSRUW6\\VWHPV LH('*('*$X[LOLDULHV(VVHQWLDO3RZHU'LVW6\\V(6:6\\VWHP6KXWGRZQ,QVWUXPHQWDWLRQ DOZD\\VUHTXLUHG



)ROORZLQJ539GHSUHVVXUL]DWLRQE\\659VDQG5&,&QRWDYDLODEOH



)ROORZLQJ539GHSUHVVXUL]DWLRQE\\659VDQG+3&,QRWDYDLODEOH



5+5SXPSXVHGIRU539,QYHQWRU\\&RQWUROFDQQRWEHVDPH5+5SXPSXVHGIRU'HFD\\+HDW5HPRYDOH[FHSWIRUWKHILQDOSDWKGHVFULEHGIRUHLWKHUGLYLVLRQXQGHU

GHFD\\KHDWUHPRYDORIWKLVWDEOH



7KRXJKQRWUHTXLUHGVDIHVKXWGRZQHTXLSPHQW5&,&LIDYDLODEOHFRXOGEHXVHG



0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

+(/%DQG6DIH6KXWGRZQ(YDOXDWLRQ

,

&RPSOLDQFH(YDOXDWLRQ 5HIHUHQFHDQG 

7KHREMHFWLYHRIWKHFRPSOLDQFHHYDOXDWLRQZDVWRHVWDEOLVKWKDWIRUDQ\\SRVWXODWHG

+(/%LQDQ\\FRPSDUWPHQWDSDWKWRVDIHVKXWGRZQH[LVWHGXVLQJWKHPLWLJDWLQJV\\VWHPV

LGHQWLILHGLQ6HFWLRQ,7KHPHWKRGRORJ\\IRUVKRZLQJWKLVFRPSOLDQFHZDVGLYLGHGLQWR

IRXUVWHSV

 

(OLPLQDWHDOOFRPSDUWPHQWVZKLFKGLGQRWFRQWDLQERWKSRVWXODWHG+(/%VDQG

66'HTXLSPHQWRUDOOFRPSDUWPHQWVFRQWDLQLQJSRVWXODWHG+(/%VZKLFK

ZRXOGQRWDGYHUVHO\\DIIHFW66'LQDGMDFHQWFRPSDUWPHQWV

 

(YDOXDWHWKHORVVRIDOO66'HTXLSPHQWIURPDSRVWXODWHG+(/%LQDVSHFLILF

FRPSDUWPHQW,IDSDWKWRVDIHVKXWGRZQH[LVWVWKHHYDOXDWLRQRIWKH

FRPSDUWPHQWLVFRPSOHWHDQGGRFXPHQWHGDFFRUGLQJO\\

 

(YDOXDWHWKHORVVRIWKH66'HTXLSPHQWDIIHFWHGE\\VSHFLILF+(/%VLQD

FRPSDUWPHQWWRGHPRQVWUDWHFRPSOLDQFH

 

3URYLGHUHFRPPHQGDWLRQVIRUSURSRVHGPRGLILFDWLRQVWRDFKLHYHFRPSOLDQFH

IRUVSHFLILFSRVWXODWHG+(/%V

6WHSZDVSHUIRUPHGXVLQJWKHGDWDREWDLQHGIURPWKHILHOGVXUYH\\V 5HIHUHQFHV

DQG DQGWKH+(/%ORFDWLRQVZHUHLGHQWLILHG$UHYLHZRIDOOFRPSDUWPHQWVZDVPDGH

WRGHWHUPLQHWKRVHFRPSDUWPHQWVLQZKLFKRQO\\66'HTXLSPHQWRUKLJKHQHUJ\\OLQHV

ZHUHORFDWHG7KHVHFRPSDUWPHQWVZHUHLGHQWLILHGDVEHLQJLQFRPSOLDQFH,QDGGLWLRQ

IRUWKHFRPSDUWPHQWVFRQWDLQLQJRQO\\KLJKHQHUJ\\OLQHVDUHYLHZZDVSHUIRUPHGWR

GHWHUPLQHLIDQ\\SRVWXODWHG+(/%VFRXOGFDXVHDGYHUVHHIIHFWVRQ66'HTXLSPHQWLQ

DGMRLQLQJFRPSDUWPHQWV,IDQLQWHUDFWLRQGXHWRWKHHIIHFWVRID+(/%FRXOGEH

LGHQWLILHGDQHYDOXDWLRQXVLQJWKHPHWKRGVRI6WHSZDVSHUIRUPHG

6WHSLQWKHFRPSOLDQFHHYDOXDWLRQZDVWRHYDOXDWHWKHORVVRIDOO66'HTXLSPHQWLQD

JLYHQFRPSDUWPHQWDVDUHVXOWRID+(/%DQGHYDOXDWHZKHWKHUDSDWKWRVDIHVKXWGRZQ

H[LVWHG7KLVVDIHVKXWGRZQSDWKZDVWKHQDSSOLHGWRDOOSRVWXODWHG+(/%VLQWKH

FRPSDUWPHQW

)RUDQ\\FRPSDUWPHQWLQZKLFKFRPSOLDQFHFRXOGQRWEHGHPRQVWUDWHGDQHYDOXDWLRQRI

VSHFLILF+(/%VZDVFRQGXFWHG 6WHS WRGHWHUPLQHWKH66'HTXLSPHQWDGYHUVHO\\

DIIHFWHGE\\DEUHDNDQGSRWHQWLDOSDWKZD\\VWRVDIHVKXWGRZQ$JDLQFRPSOLDQFHFRXOG

EHGHPRQVWUDWHGE\\HVWDEOLVKLQJDVDIHVKXWGRZQSDWK$Q\\XQDFFHSWDEOHLQWHUDFWLRQV

UHPDLQLQJZHUHLGHQWLILHGDQGFKDQJHVWRSODQWFRQILJXUDWLRQDQGRSHUDWLQJ

UHTXLUHPHQWVZHUHPDGHWRUHPRYHWKHVHLQWHUDFWLRQV

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

,GHQWLILFDWLRQRI3RWHQWLDO7DUJHWV

7KHWDUJHWVRIWKHSRVWXODWHG+(/%VZHUHVHOHFWHGDVWKRVHV\\VWHPVFRPSRQHQWV

DQGVWUXFWXUHVUHTXLUHGWRPLWLJDWHWKHFRQVHTXHQFHVRISRVWXODWHG+(/%VDQG

DFFRPSOLVKDQGPDLQWDLQDFROGVKXWGRZQFRQGLWLRQZLWKRXWIXHOGDPDJHRUEUHDNRI

SULPDU\\FRQWDLQPHQWDVLGHQWLILHGLQWKH86$5WKH6DIH6KXWGRZQ$QDO\\VLVDQGWKH

RULJLQDO+(/%5HSRUW 5HIHUHQFH 

7DUJHWVLQFOXGHIORRUVZDOOVFRPSDUWPHQWERXQGDULHVDQGRWKHUV\\VWHPVZKHUH

IDLOXUHVRIWKHERXQGDU\\RUV\\VWHPLQDSRVWXODWHG+(/%FRXOGFDXVHGDPDJHRU

FUHDWHDGYHUVHFRQGLWLRQVIRUSULPDU\\VDIHVKXWGRZQHTXLSPHQW

7KHSULPDU\\DQGVHFRQGDU\\FRQWDLQPHQWERXQGDULHVDQGWKH&RQWURO5RRPDUHDOVR

FRQVLGHUHGWREHWDUJHWVRISRVWXODWHG+(/%V

,

6LQJOH$FWLYH)DLOXUH(YDOXDWLRQ

+(/%%UHDNVLQWKH0DLQVWHDPOLQH)HHGZDWHUOLQHDQG5:&8OLQHDUH

DXWRPDWLFDOO\\FRQWDLQHGZLWKLQWKHILUVWPLQXWHVE\\+3&,VWDELOL]LQJYHVVHOOHYHO

DIWHUVFUDPPLQJ,QWKLVWLPHIUDPHRQO\\(&&6FRPSRQHQWVDUHDVVXPHGWRPLWLJDWH

WKH+(/%ZLWKDVLQJOHDFWLYHIDLOXUHLQWKH(&&6FRPSRQHQWVSOXVDQDVVXPHGORVV

RIRIIVLWHSRZHU)RUHQYLURQPHQWDOIORRGLQJSXUSRVHVRIIVLWHSRZHUIRUWKH):

EUHDNZDVDVVXPHGEXWVKXWGRZQLVFRQVHUYDWLYHO\\VKRZQZLWKRXWRIIVLWHSRZHU,I

+3&,LVWKHVLQJOHIDLOXUHWKHQDGLYLVLRQRIORZSUHVVXUHLQMHFWLRQV\\VWHPV&6DQGRU

5+5DUHDXWRPDWLFDOO\\DYDLODEOHIRUYHVVHOOHYHOVWDELOL]DWLRQDIWHUGHSUHVVXUL]DWLRQ

DWZKLFKWLPHWKH+(/%DFFLGHQWLVFRQWDLQHG

$IWHULQLWLDOYHVVHOOHYHOVWDELOL]DWLRQWKHQRIIVLWHSRZHULVDVVXPHGDQGVLQJOHDFWLYH

(&&6IDLOXUHLVQRWSRVWXODWHG6'&DQG63&QRQ(&&60RGHVRI5+5DQG(&&6

HTXLSPHQWPD\\EHXVHGIRUFRQWDLQPHQWFRROLQJYHVVHOOHYHOFRQWURODQGGHFD\\KHDW

UHPRYDO$OWHUQDWH,QMHFWLRQV\\VWHPVSHU&DQG$OO$YDLODEOH7RUXV&RROLQJ

SHU&DUHDOVRDYDLODEOH

)RUHDFKFRPSDUWPHQWFRQWDLQLQJKLJKHQHUJ\\OLQHVZKHUHVDIHVKXWGRZQHTXLSPHQW

ZDVDGYHUVHO\\DIIHFWHGDVLQJOHDFWLYHIDLOXUHUHYLHZZDVFRQGXFWHGWRGHWHUPLQHWKH

VLQJOHDFWLYHIDLOXUHVWKDWFRXOGLQKLELWVDIHVKXWGRZQRIWKHXQLW$VLQJOHDFWLYHIDLOXUH

LVGHILQHGDVWKHPDOIXQFWLRQRUORVVRIIXQFWLRQRIDQHOHFWULFDORUIOXLGV\\VWHP

FRPSRQHQWH[FOXGLQJSDVVLYHIDLOXUHVZKLFKUHO\\RQPHFKDQLFDOPRYHPHQWWR

FRPSOHWHLWVLQWHQGHGIXQFWLRQXSRQGHPDQG

7KHGHWHUPLQDWLRQRISRVWXODWHGWDUJHWVDQGGLVDEOHGV\\VWHPVUHYHDOHGWKDWIRUDOO

+(/%VZLWKLQWKHSODQWWKH659VDQGWKH536HTXLSPHQWZRXOGQRWEHDGYHUVHO\\

DIIHFWHG$OVRWKHUHDUHQRVLQJOHDFWLYHIDLOXUHVZLWKLQWKHVHV\\VWHPVFRLQFLGHQWZLWK

ORVVRIRIIVLWHSRZHUZKLFKFRXOGSUHYHQWWKHVHV\\VWHPVIURPSHUIRUPLQJWKHLU

LQWHQGHGVDIHVKXWGRZQIXQFWLRQ7KHUHIRUHWKHUHDFWLYLW\\FRQWURODQGUHDFWRUYHVVHO

GHSUHVVXUL]DWLRQIXQFWLRQFRXOGDOZD\\VEHDFKLHYHG

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





KLOH5&,&LVQRWDQ(&&6V\\VWHPLWVXVHLVFUHGLWHGLQ5HIHUHQFH7DEOH7KH

UHDFWRUYHVVHOOHYHOFRQWUROIXQFWLRQLVDFKLHYHGE\\XVLQJHLWKHUWKH+3&,RU5&,&

V\\VWHPVEHIRUH539GHSUHVVXUL]DWLRQDQGE\\XVLQJRQHGLYLVLRQRIWKH&RUH6SUD\\RU

WKH/3&,PRGHRI5+5DIWHU539GHSUHVVXUL]DWLRQ,IQHLWKHU+3&,QRU5&,&LV

DIIHFWHGE\\D+(/%WKHQHLWKHUV\\VWHPFDQDFKLHYHWKHOHYHOFRQWUROIXQFWLRQ

DVVXPLQJDVLQJOHDFWLYHIDLOXUHLQHLWKHUV\\VWHP,IERWK+3&,DQG5&,&DUHORVW

WKURXJKD+(/%RU+(/%DQGVLQJOHDFWLYHIDLOXUHWKH539FDQEHGHSUHVVXUL]HG

ZLWKWKH659VDQGHLWKHUWKH/3&,PRGHRI5+5RU&6FDQEHXVHGWRUHVWRUHDQG

PDLQWDLQ539OHYHO7KH/3&,DQG&6DUHUHGXQGDQWWRHDFKRWKHUDQGHDFK

HVVHQWLDOGLYLVLRQKDVD&6DQG/3&,6\\VWHP7KHUHDUHQRVLQJOHDFWLYHIDLOXUHVLQ

WKH&6+3&,5&,&DQG/3&,0RGHRI5+5ZKLFKSUHYHQWVWKHUHDFWRUYHVVHOOHYHO

IXQFWLRQIURPEHLQJDFKLHYHG

)RUWKHSRVWXODWHG+(/%VLWFDQEHFRQFOXGHGKHUHWKDWWKHUHDUHQRFRLQFLGHQW

VLQJOHDFWLYHIDLOXUHVZKLFKZRXOGSUHYHQWVDIHVKXWGRZQRIWKHXQLW

,

+(/%(YDOXDWLRQVE\\6\\VWHP

7DEOH,LGHQWLILHVE\\FRPSDUWPHQWDQGV\\VWHPWKHORFDWLRQVRIKLJKHQHUJ\\SLSLQJ

VXEMHFWWRSRVVLEOHSLSHUXSWXUH%\\UHDGLQJDQ\\URZDGHWHUPLQDWLRQFDQEHPDGHRIDOO

FRPSDUWPHQWVLQZKLFKSLSHUXSWXUHVRIDVSHFLILFV\\VWHPDUHSRVWXODWHG$OVRE\\

H[DPLQLQJDQ\\FROXPQDGHWHUPLQDWLRQFDQEHPDGHLIDQ\\SRVWXODWHGKLJKHQHUJ\\OLQH

EUHDNVDUHORFDWHGZLWKLQDVSHFLILFFRPSDUWPHQW7KHODVWOLQHRIWKHWDEOHLGHQWLILHV

WKRVHFRPSDUWPHQWVZKLFKFRQWDLQVDIHVKXWGRZQHTXLSPHQW

7KHIROORZLQJVHFWLRQHYDOXDWHVWKHHIIHFWVRIDSRVWXODWHG+(/%RQVDIHVKXWGRZQLQ

HDFKFRPSDUWPHQWLGHQWLILHGLQ7DEOH,WKDWKDVDSRVWXODWHGEUHDNORFDWLRQRUKDV

KLJKHQHUJ\\SLSLQJWUDYHUVLQJWKHFRPSDUWPHQW7KHUHDUHQRKLJKHQHUJ\\OLQHVLQWKH

()7EXLOGLQJ7KHHYDOXDWLRQVDUHFRQGXFWHGRQDV\\VWHPEDVLVIRUHDFKFRPSDUWPHQW

(YDOXDWLRQVDUHSURYLGHGIRUHDFKKLJKHQHUJ\\V\\VWHPZLWKKLJKHQHUJ\\SLSLQJWKDWFRXOG

QRWEHH[FOXGHGIURPIXUWKHUHYDOXDWLRQE\\7DEOH,)RUHDFKV\\VWHPDQHYDOXDWLRQLV

SURYLGHGIRUHDFKFRPSDUWPHQWLQZKLFK+(/%VDUHSRVWXODWHG7KHHYDOXDWLRQV

GHVFULEHWKHHIIHFWVRISLSHZKLSMHWLPSLQJHPHQWFRPSDUWPHQWSUHVVXUL]DWLRQ

IORRGLQJDQGHQYLURQPHQWDOHIIHFWV,QIRUPDWLRQRQSDWKVWRVDIHVKXWGRZQLVJLYHQLI

WKHSRVWXODWHG+(/%VGDPDJH66'HTXLSPHQW

,

0DLQ6WHDP6\\VWHP

7KHKLJKHQHUJ\\OLQHVIRUWKH0DLQ6WHDP6\\VWHPDUHORFDWHGLQIRXUFRPSDUWPHQWV

WKHPDLQVWHDPFKDVH 9ROXPH LQWKH5HDFWRU%XLOGLQJWKHFRQGHQVHUDUHD

9ROXPH WKHVWHDPMHWDLUHMHFWRU 6-$( URRP 9ROXPH DQGWKHWXUELQH

RSHUDWLQJIORRU 9ROXPH LQWKH7XUELQH%XLOGLQJ

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

0DLQ6WHDP&KDVH 9ROXPH 

7KHPDLQVWHDPFKDVHFRQWDLQVWKHIRXUPDLQVWHDPOLQHVDQGWKHDVVRFLDWHGGUDLQ

SLSLQJ3LSHZKLSIURPWKHPDLQVWHDPOLQHVLVQRWFRQVLGHUHGDSUREOHPVLQFH

WKHVHOLQHVDUHUHVWUDLQHGDWVHYHUDOORFDWLRQVLQWKLVFRPSDUWPHQWDQGSLSHZKLS

UHDFWLRQVDUHQRWWRZDUGDQ\\66'HTXLSPHQW6LQFHWKHRQO\\SRVWXODWHGEUHDN

ORFDWLRQVDUHDWWKHRXWERDUGFRQWDLQPHQWLVRODWLRQYDOYHVDQGWKHSHQHWUDWLRQDFWV

DVDQDQFKRUSRLQWRQO\\FLUFXPIHUHQWLDOEUHDNVDUHUHTXLUHGWREHSRVWXODWHG7KH

UHVXOWDQWMHWVIURPWKHFLUFXPIHUHQWLDOEUHDNVGRQRWLPSDFWDQ\\66'HTXLSPHQW

H[FHSWIRUDVPDOOSRUWLRQRIWKHMHWZKLFKZRXOGKLWWKHFRPSDUWPHQWFHLOLQJ

,PEHGGHGLQWKHFHLOLQJDUH'LYLVLRQ,,FDEOHVRI66'HTXLSPHQWEXWWKHVHFDEOHV

ZRXOGEHXQDIIHFWHGEHFDXVHRIWKHFRQFUHWHFHLOLQJUHLQIRUFHPHQWEHORZWKH

FRQGXLWV+3&,DQG5&,&ZRXOGERWKEHDYDLODEOHWRVXSSRUWVDIHVKXWGRZQVLQFH

WKHVWHDPOLQHLVRODWLRQYDOYHVDQGLQMHFWLRQYDOYHVDUHTXDOLILHGIRUWKHDQWLFLSDWHG

VWHDPHQYLURQPHQW,QDGGLWLRQDOORWKHU66'V\\VWHPVRIERWKGLYLVLRQVZRXOGEH

DYDLODEOH'HSUHVVXUL]DWLRQLVDFFRPSOLVKHGE\\WKH+3&,RUWKH659VDQG/3&,

DQG&6FDQEHXVHGIRUGHFD\\KHDWUHPRYDODQG539OHYHOPDLQWHQDQFH

7KHUHIRUHVDIHVKXWGRZQFDQEHDFFRPSOLVKHG

7KHSRVWXODWHGPDLQVWHDPOLQHEUHDNZRXOGUXSWXUHWKHEORZRXWSDQHOVWRWKH

WXUELQHRSHUDWLQJIORRU 9ROXPH DQGIDLORSHQWKHUDLOZD\\GRRUWRWKHVRXWKVLGH

RIWKH5HDFWRU%XLOGLQJDWHOHYDWLRQIRRW7KHHIIHFWVRIWKHSUHVVXUL]DWLRQ

ZRXOGEHIURPWKHVDPHFLUFXPIHUHQWLDOEUHDNDQGWKHLGHQWLFDO66'HTXLSPHQW

ZRXOGEHDIIHFWHG1RDGGLWLRQDO66'HTXLSPHQWZRXOGEHDGYHUVHO\\DIIHFWHGDVD

UHVXOWRIWKHSUHVVXUL]DWLRQ7KHUHIRUHVDIHVKXWGRZQFRXOGEHDFFRPSOLVKHGLQ

WKHVDPHPDQQHUDVGHVFULEHGDERYH

7KHFRQVHTXHQFHVRIFRPSDUWPHQWIORRGLQJZDVHYDOXDWHGDQGQRDGGLWLRQDO66'

HTXLSPHQWZRXOGEHDIIHFWHG7KH+3&,DQG5&,&LQMHFWLRQYDOYHVZRXOGUHPDLQ

DYDLODEOHGXHWRWKHKHLJKWRIWKHRSHUDWRUVDERYHWKHIORRU aIW :DWHUZRXOG

QRWOHDYHWKHDUHDVLQFHWKHERWWRPRIWKHGRRURSHQLQJLVIHHWDERYHWKH

FRPSDUWPHQWIORRUHOHYDWLRQ

7KHHIIHFWVRIWKHPDLQVWHDPOLQHEUHDNLQWKLVFRPSDUWPHQWZHUHXVHGIRU

HQYLURQPHQWDOTXDOLILFDWLRQSXUSRVHV7KHUHIRUHQRDGGLWLRQDO66'HTXLSPHQWZLOO

EHDGYHUVHO\\DIIHFWHGDQGWKHSUHYLRXVO\\LGHQWLILHGSDWKWRVDIHVKXWGRZQFDQEH

XWLOL]HG

%UHDNVRQWKHPDLQVWHDPGUDLQOLQH 36(% ZHUHHYDOXDWHGDQGIRXQGWR

EHERXQGHGE\\WKHRWKHUPDLQVWHDPOLQHEUHDNHYDOXDWLRQV

,WLVWKHUHIRUHFRQFOXGHGWKDWDSDWKWRVDIHVKXWGRZQH[LVWVIRUDQ\\SRVWXODWHG

PDLQVWHDPEUHDNLQWKHPDLQVWHDPFKDVH

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

6-$(5RRP 9ROXPH 

7KHPDLQVWHDPSLSLQJOLQH 36(' LVURXWHGWRWKH6-$(5RRPIURPWKH

&RQGHQVHUDUHD1RFRQFHUQH[LVWVZLWKUHVSHFWWRSLSHZKLSDQGMHWLPSLQJHPHQW

VLQFHWKHUHLVQR66'HTXLSPHQWLQWKHDUHD7KHFRQVHTXHQFHVRIFRPSDUWPHQW

IORRGLQJZDVHYDOXDWHG6LQFHWKHUHLVQR66'HTXLSPHQWLQWKHURRPWKHUHZDV

QRQHJDWLYHHIIHFW$OVRWKHGUDLQVLQWKHURRPFDQGUDLQWKHHQWLUHYROXPHWRWKH

VXPSDUHD,QDGGLWLRQWKHGRRUWRWKH6-$(URRPLVEDUUHGDQGDLUWLJKW$Q\\

OHDNDJHDVDUHVXOWRIWKHIORRGLQJZRXOGEHQHJOLJLEOH

&RPSDUWPHQWSUHVVXUL]DWLRQDQGHQYLURQPHQWDOHIIHFWVIURPWKLVVWHDPOLQHEUHDN

ZRXOGQRWDGYHUVHO\\DIIHFWDQ\\66'HTXLSPHQW7KH6-$(KDWFKSOXJKDVEHHQ

PRGLILHGDQGWKH6-$(KDVDGHTXDWHYHQWDUHDVWRWKH&RQGHQVHUED\\

9ROXPH DQGWRWKHIRRWHOHYDWLRQRIWKH7XUELQH%XLOGLQJ7KHGRRUWRWKH

6-$(5RRPKDVDOVREHHQPRGLILHGWRZLWKVWDQGWKHSUHVVXUL]DWLRQ7KLVEUHDN

GRHVQRWFDXVH5HDFWRU3URWHFWLYHLQLWLDWLRQVLQFHWKHEUHDNIORZLVOHVVWKDQWKH

  • URXSIORZWULSSRLQW 5HIHUHQFH(UUDWD 7KHUHIRUHVLQJOHIDLOXUHDQGORVVRI

RIIVLWHSRZHUFRQVLGHUDWLRQVDUHQRWDSSOLFDEOH

66'HTXLSPHQWDGYHUVHO\\DIIHFWHGDUH'LYLVLRQ,0&&$DQG0&&%GXH

WRKLJKWHPSHUDWXUH'LYLVLRQ,,HTXLSPHQWZLWK+3&,DUHDYDLODEOHIRUYHVVHO

LQYHQWRU\\ZLWKVXEVHTXHQWVDIHVKXWGRZQ'LYLVLRQ,,&6LVDXWRPDWLFDOO\\DYDLODEOH

IRU9HVVHO,QYHQWRU\\PDNHXSDIWHU659GHSUHVVXUL]DWLRQDQG5+56XSSUHVVLRQ

3RROFRROLQJLVDYDLODEOHIRUFRQWDLQPHQWDQGGHFD\\KHDWUHPRYDO$OWHUQDWH

,QMHFWLRQV\\VWHPVSHU&DQG$OO$YDLODEOH7RUXV&RROLQJSHU&DUH

DOVRDYDLODEOH

,

&RQGHQVHU$UHD 9ROXPH 

 ,QFK6WHDP/LQHV

7KLVEUHDNFDXVHV5HDFWRU3URWHFWLYHLQLWLDWLRQEHFDXVH06,9 VFORVHRQD

  • URXS,GXHWRIORZ7KHUHIRUHVLQJOHIDLOXUHZLWKORVVRIRIIVLWHSRZHULV

DSSOLFDEOHGXULQJWKHLQLWLDOYHVVHOOHYHOVWDELOL]DWLRQSHULRG

66'HTXLSPHQWDGYHUVHO\\DIIHFWHGLV'LYLVLRQ,0&&$DQG0&&%

GXHWRKLJKWHPSHUDWXUHDQGEHLQJIORRGHGDQG',9,5+56:/LQH

6:*)GXHWRSLSHZKLS,WLVDVVXPHG'LYLVLRQ,,/3&,LQMHFWLRQLVQRW

DYDLODEOHVLQFHWKHSRZHUIRUWKH/3&,LQMHFWLRQYDOYHVLQ'LY,,0&&%KDYH

EHHQKDUGZLUHGWR'LY,0&&%IRU/3&,ORRSVHOHFWORJLFGXULQJD/2&$

,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQ3HULRG6LQJOHIDLOXUHZLWKORVVRIRIIVLWHSRZHU

x +3&,LIVLQJOHIDLOXUHWKHQ

x 659ZLWK'LYLVLRQ,,&6

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





3RVW,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQ3HULRG1RVLQJOHIDLOXUHQRORVVRIRIIVLWH

SRZHU

x 9HVVHO/HYHO

+3&,RU

659ZLWK'LYLVLRQ,,&6RU

$OWHUQDWH,QMHFWLRQV\\VWHPVSHU&

x &RQWDLQPHQW&RROLQJDQG'HFD\\+HDW5HPRYDO

'LY,,&6659'LY,,5+5 63& 'LY,,5+5+HDW([FKDQJHU'LY,,5+56:

3XPSDQGRU$OWHUQDWH,QMHFWLRQV\\VWHPVSHU&$OO$YDLODEOH7RUXV

&RROLQJSHU& 

 ,QFK6WHDP/LQH%\\SDVV36('

7KLVEUHDNE\\LWVHOIGRHVQRWFDXVH5HDFWRU3URWHFWLYHLQLWLDWLRQ 5HIHUHQFH

(UUDWD 7KHUHIRUHVLQJOHIDLOXUHDQGORVVRIRIIVLWHSRZHUFRQVLGHUDWLRQVDUH

QRWDSSOLFDEOH

66'HTXLSPHQWDGYHUVHO\\DIIHFWHGLV+3&,SRZHUFDEOHVDQGRQHGLYLVLRQRI

6327026WRUXVWHPSHUDWXUHLQVWUXPHQWFDEOHGXHWRSLSHZKLSDQG'LYLVLRQ,

0&&$DQG0&&%GXHWRKLJKWHPSHUDWXUH'LYLVLRQ,,&6LV

DXWRPDWLFDOO\\DYDLODEOHIRU9HVVHO,QYHQWRU\\PDNHXSDIWHU659

GHSUHVVXUL]DWLRQDQG'LYLVLRQ,,5+56XSSUHVVLRQ3RROFRROLQJLVDYDLODEOHIRU

FRQWDLQPHQWDQGGHFD\\KHDWUHPRYDO$OWHUQDWH,QMHFWLRQV\\VWHPVSHU

&DQG$OO$YDLODEOH7RUXV&RROLQJSHU&DUHDOVRDYDLODEOH

,

7XUELQH2SHUDWLQJ)ORRU 9ROXPH 

7KHRQO\\SRVWXODWHG+(/%VLQWKLVFRPSDUWPHQWIURPWKHPDLQVWHDPV\\VWHPDUH

EUHDNVDWWKHLQOHWWRWKH+LJK3UHVVXUH7XUELQH$EUHDNDWWKLVORFDWLRQZRXOGQRW

H[SRVHDQ\\66'HTXLSPHQWWRHLWKHUSLSHZKLSRUMHWLPSLQJHPHQWDVWKHUHLVQR

66'HTXLSPHQWLQWKLVDUHD(QYLURQPHQWDOHIIHFWVDUHHYDOXDWHGLQWKH01*3

(QYLURQPHQWDO4XDOLILFDWLRQ (4 SURJUDPEDVHGRQWKHEUHDNFDVHVLGHQWLILHGLQ

WKLV$SSHQGL[%RXQGLQJSURILOHVIRUHQYLURQPHQWDOFRQGLWLRQVDUHLGHQWLILHG7KH

HQYLURQPHQWDOFRQGLWLRQVLQFOXGHFRPSDUWPHQWSUHVVXUL]DWLRQKHDWXSDQG

IORRGLQJHIIHFWV$Q\\ZDWHUFRQGHQVLQJZRXOGGUDLQHLWKHUWRWKH&RQGHQVHUED\\RU

ORZHUHOHYDWLRQVRIWKH7XUELQH%XLOGLQJWRDUHDVZKHUHWKHZDWHUFRXOGEHGUDLQHG

7KH66'HTXLSPHQWLQWKHVHDUHDVZRXOGQRWEHDGYHUVHO\\DIIHFWHGE\\WKHZDWHU

SURGXFHG+(/%EDUULHUVKDYHEHHQLQVWDOOHGWRSUHYHQWHQYLURQPHQWDOHIIHFWV

IURPEUHDNVRQWKHWXUELQHRSHUDWLQJIORRUIURPDIIHFWLQJ66'HTXLSPHQWLQWKH'LY

,,.9DQG'LY,,(VVHQWLDO0&&DUHDV 9ROXPHVDQG 

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

)HHGZDWHU6\\VWHP

7KHKLJKHQHUJ\\OLQHVIRUWKH)HHGZDWHU6\\VWHPDUHORFDWHGLQWKHIHHGZDWHUSXPS

DUHD 9ROXPHVDQG 7XUELQH%XLOGLQJSLSHFKDVH 9ROXPH WXUELQHRSHUDWLQJ

IORRU 9ROXPH FRQGHQVHUDUHD 9ROXPH LQWKH7XUELQH%XLOGLQJDQGWKHPDLQ

VWHDPFKDVH 9ROXPH LQWKH5HDFWRU%XLOGLQJ

7KHWZRIHHGZDWHUOLQHVDQGWKHIHHGZDWHUUHJXODWLQJVWDWLRQSLSLQJZHUHVHLVPLFDOO\\

DQDO\\]HG%UHDNORFDWLRQVZHUHVHOHFWHGEDVHGXSRQWKHVHLVPLFDQDO\\VLVRIWKH

SLSLQJDQGWKHEUHDNORFDWLRQFULWHULDHVWDEOLVKHGIRUVHLVPLF&ODVV,SLSLQJ7KHUH

ZHUHQREUHDNORFDWLRQVLQWKH7XUELQH%XLOGLQJSLSHFKDVH 9ROXPH 

,

5HDFWRU)HHGZDWHU3XPS$UHD9ROXPHVDQG

7KLVEUHDNFDXVHV5HDFWRU3URWHFWLYHLQLWLDWLRQEHFDXVHDORVVRI)HHGZDWHU

FDXVHVYHVVHOORZZDWHUOHYHOWKDWFDXVHVDVFUDP7KHUHIRUHVLQJOHIDLOXUHZLWK

ORVVRIRIIVLWHSRZHULVDSSOLFDEOHGXULQJWKHLQLWLDOYHVVHOOHYHOVWDELOL]DWLRQSHULRG

66'HTXLSPHQWDGYHUVHO\\DIIHFWHGLV'LYLVLRQ,0&&$DQG0&&%GXHWR

KLJKWHPSHUDWXUHDQGEHLQJIORRGHG,WLVDVVXPHG'LYLVLRQ,,/3&,LQMHFWLRQLVQRW

DYDLODEOHVLQFHWKHSRZHUIRUWKH/3&,LQMHFWLRQYDOYHVLQ'LY,,0&&%KDYH

EHHQKDUGZLUHGWR'LY,0&&%IRU/3&,ORRSVHOHFWORJLFGXULQJD/2&$3LSH

ZKLSUHVWUDLQWVKDYHEHHQLQVWDOOHGQHDUWKHSLSHWHUPLQDOHQGVDWWKH):SXPSVWR

SUHYHQWGDPDJHWRWKHFHLOLQJDERYHWKDWSURYLGHVIORRUVXSSRUWWRWKH'LY,,

0&&

V

,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQ3HULRG6LQJOHIDLOXUHZLWKORVVRIRIIVLWHSRZHU

x +3&,LIVLQJOHIDLOXUHWKHQ

x 659ZLWK'LYLVLRQ,,&6

3RVW,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQ3HULRG1RVLQJOHIDLOXUHQRORVVRIRIIVLWH

SRZHU

x 9HVVHO/HYHO

+3&,RU

659ZLWK'LYLVLRQ,,&6RU

$OWHUQDWH,QMHFWLRQV\\VWHPVSHU&

x &RQWDLQPHQW&RROLQJDQG'HFD\\+HDW5HPRYDO

'LY,,&6659'LY,,5+5 63& 'LY,,5+5+HDW([FKDQJHU'LY,,5+56:

3XPSDQGRU$OWHUQDWH,QMHFWLRQV\\VWHPVSHU&$OO$YDLODEOH7RUXV

&RROLQJSHU&

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

7XUELQH%XLOGLQJ3LSH&KDVH 9ROXPH 

7KHUHDUHQRSRVWXODWHGIHHGZDWHUOLQHEUHDNVZLWKLQWKLVFRPSDUWPHQW7KXVSLSH

ZKLSMHWLPSLQJHPHQWIORRGLQJDQGFRPSDUWPHQWSUHVVXUL]DWLRQHIIHFWVUHVXOW

IURPEUHDNVLQRWKHUDUHDV 9ROXPHVDQG 6LQFHWKHUHDUHQREUHDNVLQWKLV

9ROXPHRQO\\WHPSHUDWXUHDQGFRPSDUWPHQWSUHVVXUL]DWLRQFUHDWHHQYLURQPHQWDO

FRQFHUQVLQ9ROXPH(QYLURQPHQWDOHIIHFWVDUHHYDOXDWHGLQWKH01*3

(QYLURQPHQWDO4XDOLILFDWLRQ (4 SURJUDPEDVHGRQWKHEUHDNFDVHVLGHQWLILHGLQ

WKLV$SSHQGL[%RXQGLQJSURILOHVIRUHQYLURQPHQWDOFRQGLWLRQVDUHLGHQWLILHG7KH

HQYLURQPHQWDOFRQGLWLRQVLQFOXGHFRPSDUWPHQWSUHVVXUL]DWLRQKHDWXSDQG

IORRGLQJHIIHFWV

,

7XUELQH2SHUDWLQJ)ORRU 9ROXPH 

7KLVEUHDNFDXVHV5HDFWRU3URWHFWLYHLQLWLDWLRQEHFDXVHDORVVRI)HHGZDWHU

FDXVHVYHVVHOORZZDWHUOHYHOWKDWFDXVHVDVFUDP7KHUHIRUHVLQJOHIDLOXUHZLWK

ORVVRIRIIVLWHSRZHULVDSSOLFDEOHGXULQJWKHLQLWLDOYHVVHOOHYHOVWDELOL]DWLRQSHULRG

66'HTXLSPHQWDGYHUVHO\\DIIHFWHGLV'LYLVLRQ,0&&$DQG0&&%GXHWR

KLJKWHPSHUDWXUHDQGEHLQJIORRGHG,WLVDVVXPHG'LYLVLRQ,,/3&,LQMHFWLRQLVQRW

DYDLODEOHVLQFHWKHSRZHUIRUWKH/3&,LQMHFWLRQYDOYHVLQ'LY,,0&&%KDYH

EHHQKDUGZLUHGWR'LY,0&&%IRU/3&,ORRSVHOHFWORJLFGXULQJD/2&$

,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQ3HULRG6LQJOHIDLOXUHZLWKORVVRIRIIVLWHSRZHU

x +3&,LIVLQJOHIDLOXUHWKHQ

x 659ZLWK'LYLVLRQ,,&6

3RVW,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQ3HULRG1RVLQJOHIDLOXUHQRORVVRIRIIVLWH

SRZHU

x 9HVVHO/HYHO

+3&,RU

659ZLWK'LYLVLRQ,,&6RU

$OWHUQDWH,QMHFWLRQV\\VWHPVSHU&

x &RQWDLQPHQW&RROLQJDQG'HFD\\+HDW5HPRYDO

'LY,,&6659'LY,,5+5 63& 'LY,,5+5+HDW([FKDQJHU'LY,,5+56:

3XPSDQGRU$OWHUQDWH,QMHFWLRQV\\VWHPVSHU&$OO$YDLODEOH7RUXV

&RROLQJSHU&

7KHUHVXOWDQWIORRGLQJZRXOGGUDLQEDFNWRWKH&RQGHQVHUDUHD 9ROXPH 7KH

FDVFDGLQJZDWHUZRXOGQRWDGYHUVHO\\DIIHFWDQ\\66'HTXLSPHQW

1RVDIHVKXWGRZQHTXLSPHQWLVORFDWHGRQWKHWXUELQHRSHUDWLQJIORRU

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

0DLQ6WHDP&KDVH 9ROXPH 

7KHRQO\\SRVWXODWHGEUHDNORFDWLRQVLQWKLVDUHDFRQVLVWRIWKHWHUPLQDOHQGDWHDFK

RXWERDUGFRQWDLQPHQWLVRODWLRQYDOYH ):  )RUDEUHDNDWWKHWHUPLQDO

SRLQWRQOLQH):$('DWWKH):RXWERDUGZHOG5&,&IORZZRXOGEHORVW

EHFDXVHWKH5&,&LQMHFWLRQOLQH ):(' FRQQHFWVXSVWUHDPRIWKHSRVWXODWHG

EUHDN)RUIHHGZDWHUOLQH):%('DEUHDNDWWKHWHUPLQDOHQGDWWKH

):RXWERDUGZHOGZRXOGFDXVHWKHORVVRIWKH+3&,6\\VWHPEHFDXVHWKH

+3&,LQMHFWLRQSRLQWLVXSVWUHDPRIWKHEUHDN1RVDIHVKXWGRZQHTXLSPHQWFDQEH

DGYHUVHO\\DIIHFWHGE\\SLSHZKLSRUGLUHFWMHWLPSLQJHPHQWIURPDQ\\SLSHEUHDNRI

WKH)HHGZDWHU6\\VWHPLQWKH5HDFWRU%XLOGLQJVWHDPFKDVH+RZHYHUIRU

FRQVHUYDWLVPERWK+3&,DQG5&,&DUHDVVXPHGORVWGXHWRIORRGLQJ GHVFULEHG

EHORZ DQGSRVVLEOHMHWLPSLQJHPHQWGXHWRFRPSDUWPHQWJHRPHWU\\

)ORRGLQJLQWKH5HDFWRU%XLOGLQJVWHDPFKDVHDVDUHVXOWRIDIHHGZDWHUOLQHEUHDN

ZRXOGFDXVHWKHORVVRIERWK+3&,DQG5&,&VLQFHWKHLQMHFWLRQYDOYHVIRUWKHVH

V\\VWHPV 02DQG02 ZRXOGEHVXEPHUJHGDERYHWKHPRWRU

RSHUDWRUVDWWKHSHDN+(/%IORRGOHYHO:DWHUH[LWLQJWKHVWHDPFKDVHZRXOGIORZ

DORQJWKHIORRURIWKH5HDFWRU%XLOGLQJIRRWHOHYDWLRQ6RPHRIWKHZDWHUZRXOG

DOVRIORZGRZQWRWKH&RQWURO5RG'ULYHSXPSURRP 9ROXPH DQGLQWRWKH(OHY

IRRWWDQNDQG+3&,SXPSURRPV$GGLWLRQDOVDIHVKXWGRZQHTXLSPHQWZRXOG

QRWEHDIIHFWHGE\\WKHZDWHUH[LWLQJWKHVWHDPFKDVHEHFDXVHQR66'HTXLSPHQW

UHTXLUHGWRPLWLJDWHWKLVEUHDNLVORFDWHGLQWKHDIIHFWHGDUHDV7KHUHIRUHWKH

IORRGLQJIURPWKHSRVWXODWHGIHHGZDWHUOLQHEUHDNRIHLWKHUIHHGZDWHUOLQHZRXOG

DGYHUVHO\\DIIHFWRQO\\+3&,DQG5&,&7KHSDWKWRVDIHVKXWGRZQZRXOGEHWKH

VDPHDVWKDWGHVFULEHGLQ6HFWLRQ,ZLWKWKHH[FHSWLRQWKDWDQ5+5RU&6

SXPSZRXOGEHUHTXLUHGWRPDLQWDLQ539OHYHO

7KHPDLQVWHDPOLQHEUHDNSURYLGHVWKHERXQGLQJFDVHLQWKHVWHDPFKDVHIRU

WHPSHUDWXUHDQGFRPSDUWPHQWSUHVVXUL]DWLRQ)ORRGLQJHIIHFWVIURPWKHIHHGZDWHU

EUHDNUHPRYH5&,&+3&,IURPWKHDYDLODEOHVDIHVKXWGRZQHTXLSPHQWKRZHYHUD

VDIHVKXWGRZQSDWKH[LVWVIRUERWKEUHDNFDVHV

,QVXPPDU\\D)HHGZDWHU/LQHEUHDNLQWKHPDLQVWHDPFKDVH 9ROXPH FRXOG

DGYHUVHO\\DIIHFW+3&,DQG5&,&7KHHPHUJHQF\\VHUYLFHZDWHUOLQH

6:%+)ZRXOGQRWEHDGYHUVHO\\DIIHFWHGIURPDIHHGZDWHUOLQHEUHDN3DWKV

WRVDIHVKXWGRZQZRXOGLQFOXGHXVLQJWKH659VWRGHSUHVVXUL]HWKH539XVLQJ

&6IRU539OHYHOPDLQWHQDQFHDQG5+5IRUGHFD\\KHDWUHPRYDO1RSRVWXODWHG

VLQJOHDFWLYHIDLOXUHSUHYHQWVWKHRWKHUGLYLVLRQIURPDFKLHYLQJVDIHVKXWGRZQ

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

&RQGHQVHU$UHD 9ROXPH 

7KLVEUHDNFDXVHV5HDFWRU3URWHFWLYHLQLWLDWLRQEHFDXVHDORVVRI)HHGZDWHU

FDXVHVYHVVHOORZZDWHUOHYHOWKDWFDXVHVDVFUDP7KHUHIRUHVLQJOHIDLOXUHZLWK

ORVVRIRIIVLWHSRZHULVDSSOLFDEOHGXULQJWKHLQLWLDOYHVVHOOHYHOVWDELOL]DWLRQSHULRG

66'HTXLSPHQWDGYHUVHO\\DIIHFWHGLV'LYLVLRQ,0&&$DQG0&&%GXHWR

KLJKWHPSHUDWXUHDQGEHLQJIORRGHG,WLVDVVXPHG'LYLVLRQ,,/3&,LQMHFWLRQLVQRW

DYDLODEOHVLQFHWKHSRZHUIRUWKH/3&,LQMHFWLRQYDOYHVLQ'LY,,0&&%KDYH

EHHQKDUGZLUHGWR'LY,0&&%IRU/3&,ORRSVHOHFWORJLFGXULQJD/2&$

,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQ3HULRG6LQJOHIDLOXUHZLWKORVVRIRIIVLWHSRZHU

x +3&,LIVLQJOHIDLOXUHWKHQ

x 659ZLWK'LYLVLRQ,,&6

3RVW,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQ3HULRG1RVLQJOHIDLOXUHQRORVVRIRIIVLWH

SRZHU

x 9HVVHO/HYHO

+3&,RU

659ZLWK'LYLVLRQ,,&6RU

$OWHUQDWH,QMHFWLRQV\\VWHPVSHU&

x &RQWDLQPHQW&RROLQJDQG'HFD\\+HDW5HPRYDO

'LY,,&6659'LY,,5+5 63& 'LY,,5+5+HDW([FKDQJHU'LY,,5+56:

3XPSDQGRU$OWHUQDWH,QMHFWLRQV\\VWHPVSHU&$OO$YDLODEOH7RUXV

&RROLQJSHU&

,

&RQGHQVDWH6\\VWHP

7KHKLJKHQHUJ\\&RQGHQVDWH6\\VWHPOLQHVDUHORFDWHGLQWKHFRQGHQVHUDUHD

9ROXPH 7XUELQH%XLOGLQJSLSHFKDVHDUHD 9ROXPH DQGIHHGZDWHUSXPS

DUHD 9ROXPHVDQG LQWKH7XUELQH%XLOGLQJ

%UHDNORFDWLRQVIRUSRUWLRQVRIWKHFRQGHQVDWHV\\VWHPSLSLQJZHUHVHOHFWHGEDVHG

XSRQDVHLVPLFDQDO\\VLVRIWKHSLSLQJDQGEUHDNORFDWLRQFULWHULDHVWDEOLVKHGIRU

&ODVV,SLSLQJ

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

&RQGHQVHU$UHD 9ROXPH 

7KLVEUHDNFDXVHV5HDFWRU3URWHFWLYHLQLWLDWLRQEHFDXVHDORVVRI)HHGZDWHU

FDXVHVYHVVHOORZZDWHUOHYHOWKDWFDXVHVDVFUDP7KHUHIRUHVLQJOHIDLOXUHZLWK

ORVVRIRIIVLWHSRZHULVDSSOLFDEOHGXULQJWKHLQLWLDOYHVVHOOHYHOVWDELOL]DWLRQSHULRG

66'HTXLSPHQWDGYHUVHO\\DIIHFWHGLV'LYLVLRQ,0&&$DQG0&&%GXHWR

KLJKWHPSHUDWXUHDQGEHLQJIORRGHG,WLVDVVXPHG'LYLVLRQ,,/3&,LQMHFWLRQLVQRW

DYDLODEOHVLQFHWKHSRZHUIRUWKH/3&,LQMHFWLRQYDOYHVLQ'LY,,0&&%KDYH

EHHQKDUGZLUHGWR'LY,0&&%IRU/3&,ORRSVHOHFWORJLFGXULQJD/2&$

,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQ3HULRG6LQJOHIDLOXUHZLWKORVVRIRIIVLWHSRZHU

x +3&,LIVLQJOHIDLOXUHWKHQ

x 659ZLWK'LYLVLRQ,,&6

3RVW,QLWLDO9HVVHO/HYHO6WDELOL]DWLRQ3HULRG1RVLQJOHIDLOXUHQRORVVRIRIIVLWH

SRZHU

x 9HVVHO/HYHO

+3&,RU

659ZLWK'LYLVLRQ,,&6RU

$OWHUQDWH,QMHFWLRQV\\VWHPVSHU&

x &RQWDLQPHQW&RROLQJDQG'HFD\\+HDW5HPRYDO

'LY,,&6659'LY,,5+5 63& 'LY,,5+5+HDW([FKDQJHU'LY,,5+56:

3XPSDQGRU$OWHUQDWH,QMHFWLRQV\\VWHPVSHU&$OO$YDLODEOH7RUXV

&RROLQJSHU&

,

7XUELQH%XLOGLQJ3LSH&KDVH 9ROXPH 

7KHUHDUHQRSRVWXODWHGFRQGHQVDWHOLQH+(/%VZLWKLQWKLVFRPSDUWPHQW

,

5HDFWRU)HHGZDWHU3XPS$UHD 9ROXPHVDQG 

7KHSRVWXODWHGFRQGHQVDWHOLQH+(/%VLQWKHVHFRPSDUWPHQWVZRXOGQRWDIIHFW

DQ\\DGGLWLRQDO66'HTXLSPHQWRWKHUWKDQWKH66'HTXLSPHQWGHVFULEHGIRUD

IHHGZDWHUOLQHEUHDNLQWKHVDPHFRPSDUWPHQW7KHHIIHFWVRISLSHZKLSMHW

LPSLQJHPHQWIORRGLQJFRPSDUWPHQWSUHVVXUL]DWLRQDQGHQYLURQPHQWDOHIIHFWV

DUHOHVVDGYHUVHWKDQIRUWKHIHHGZDWHUOLQHEUHDN7KHUHIRUHWKHVDPH

HYDOXDWLRQVDVSURYLGHGLQ6HFWLRQ,RIWKLVUHSRUWDSSO\\DQGWKHVDPH

SDWKVWRVDIHVKXWGRZQFDQEHXVHG

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

+LJK3UHVVXUH&RRODQW,QMHFWLRQ 6WHDP 6\\VWHP

7KHVWHDPVXSSO\\OLQH 36(' WRWKH+3&,7XUELQHLVORFDWHGLQWKHVWHDP

FKDVH 9ROXPH 7KHWRUXVDUHD 9ROXPHVDQG DQG+3&,FRPSDUWPHQWDUHD

9ROXPH 

,

0DLQ6WHDP&KDVH 9ROXPH 

3RVVLEOHSLSHZKLSWDUJHWVLQFOXGHWKHIHHGZDWHUDQGPDLQVWHDPOLQHVZKLFKDUH

DVVXPHGWREHXQDIIHFWHGEHFDXVHWKH\\DUHODUJHUDQGWKLFNHUZDOOHGWKDQWKH

+3&,VWHDPOLQH1RRWKHU66'HTXLSPHQWLVDIIHFWHGE\\D+3&,VWHDPOLQHSLSH

ZKLS

-HWLPSLQJHPHQWWDUJHWVLQFOXGHWKHFHLOLQJWKURXJKZKLFK'LYLVLRQ,,HPEHGGHG

FRQGXLWVDUHURXWHG7KHHIIHFWVRIMHWLPSLQJHPHQWRQWKHFHLOLQJLVGLVFXVVHGLQ

6HFWLRQ,+RZHYHUWKHHQYLURQPHQWDOHIIHFWVIURPD+3&,VWHDPOLQH

EUHDNDUHOHVVVHYHUHWKDQDEUHDNRIRQHRIWKHPDLQVWHDPOLQHV

)RUWKLVSRVWXODWHG+(/%WKHSDWKWRVDIHVKXWGRZQZRXOGFRQVLVWRIXVLQJWKH

659VIRU539GHSUHVVXUL]DWLRQDQG'LYLVLRQ,&6WRPDLQWDLQUHDFWRUZDWHUOHYHO

DQG'LYLVLRQ,5+5WRUHPRYHGHFD\\KHDW1RVLQJOHDFWLYHIDLOXUHFDQSUHYHQWWKH

XVHRIHLWKHUHVVHQWLDOGLYLVLRQWRVDIHO\\VKXWGRZQWKHXQLW

&RPSDUWPHQWIORRGLQJZRXOGQRWDIIHFWDQ\\66'HTXLSPHQW7KH+3&,VWHDPOLQH

EUHDNLVERXQGHGE\\WKHPDLQVWHDPOLQHEUHDNWKHUHIRUHDQ\\HQYLURQPHQWDO

HIIHFWVZLOOEHOHVVVHYHUH7KXVDSDWKWRVDIHVKXWGRZQKDVEHHQGHPRQVWUDWHG

,VRODWLRQRIWKH+3&,VWHDPOLQH36('LVDVVXUHGVLQFHWKHWHUPLQDOHQG

EUHDNFDQQRWWDUJHWWKHRXWERDUGFRQWDLQPHQWLVRODWLRQYDOYH02RUWKH

FDEOLQJWRWKHYDOYH7KHUHIRUHHYHQZLWKDVLQJOHDFWLYHIDLOXUHWRHLWKHU

FRQWDLQPHQWLVRODWLRQYDOYHRQOLQH36('LVRODWLRQRIWKHEUHDNLV

DFFRPSOLVKHGZLWKWKHUHPDLQLQJFRQWDLQPHQWLVRODWLRQYDOYH

,

7RUXV$UHD 9ROXPHVDQG 

1RLQWHUPHGLDWHEUHDNORFDWLRQVZHUHSRVWXODWHGRQWKH+3&,6WHDPOLQHLQWKLV

FRPSDUWPHQW

,

5&,& 6WHDP 6\\VWHP

7KHKLJKHQHUJ\\SLSLQJIRUWKH5&,&6\\VWHPLVORFDWHGLQWKHVWHDPFKDVH

9ROXPH WKHWRUXVDUHD 9ROXPH DQG5&,&FRPSDUWPHQW 9ROXPH LQWKH

5HDFWRU%XLOGLQJ

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

0DLQ6WHDP&KDVH 9ROXPH 

)RUDSRVWXODWHG+(/%RQWKH5&,&VWHDPOLQHWKHRQO\\66'HTXLSPHQWDIIHFWHG

E\\HLWKHUSLSHZKLSRUMHWLPSLQJHPHQWZRXOGEHWKHFHLOLQJWRWKHFRPSDUWPHQWLQ

ZKLFK'LYLVLRQ,,FRQWURODQGSRZHUFDEOHVDUHORFDWHGDQGWKH+3&,VWHDPOLQH

36(' 7KHHIIHFWVRQWKHFHLOLQJDUHERXQGHGE\\HIIHFWVIURPDSRVWXODWHG

PDLQVWHDPOLQHEUHDNDQGVRKDYHQRLPSDFWRQVDIHVKXWGRZQ'XHWRWKH

SRWHQWLDOMHWRULHQWDWLRQWKHORVVRIWKH+3&,VWHDPOLQHDQGKHQFHWKH+3&,

6\\VWHPZDVDVVXPHG)RUWKLVSRVWXODWHG+(/%WKHSDWKWRVDIHVKXWGRZQZRXOG

FRQVLVWRIXVLQJWKH659VIRU539GHSUHVVXUL]DWLRQDQG'LYLVLRQ,&6WRPDLQWDLQ

UHDFWRUZDWHUOHYHODQG'LYLVLRQ,5+5WRUHPRYHGHFD\\KHDW1RVLQJOHDFWLYH

IDLOXUHFDQSUHYHQWWKHXVHRIHLWKHUHVVHQWLDOGLYLVLRQWRVDIHO\\VKXWGRZQWKHXQLW

)ORRGLQJIURPWKH5&,&VWHDPOLQHEUHDNLQWKHPDLQVWHDPFKDVHDVVXPLQJDOO

VWHDPFRQGHQVHVDQGUHPDLQVLQWKHFRPSDUWPHQWZRXOGEHERXQGHGE\\WKHPDLQ

VWHDPOLQHEUHDN7KHHQYLURQPHQWDOFRQGLWLRQVJHQHUDWHGERWKLQWKHPDLQVWHDP

FKDVHDQGLQDGMRLQLQJFRPSDUWPHQWVZRXOGEHERXQGHGE\\WKHHIIHFWVRID

SRVWXODWHGPDLQVWHDPOLQHEUHDN7KHUHIRUHQRQHZDGYHUVHFRQGLWLRQVKDYH

EHHQSURGXFHGDQGSDWKVWRVDIHVKXWGRZQGHVFULEHGIRUWKHSRVWXODWHGPDLQ

VWHDPOLQHEUHDNDUHDSSOLFDEOHKHUH

,VRODWLRQRIWKH5&,&VWHDPOLQH36('LVDVVXUHGVLQFHWKHWHUPLQDOHQG

EUHDNFDQQRWWDUJHWWKHRXWERDUGFRQWDLQPHQWLVRODWLRQYDOYH02RUWKH

FDEOLQJWRWKHYDOYH7KHUHIRUHHYHQZLWKDVLQJOHDFWLYHIDLOXUHWRHLWKHU

FRQWDLQPHQWLVRODWLRQYDOYHRQOLQH36('LVRODWLRQRIWKHEUHDNLV

DFFRPSOLVKHGZLWKWKHUHPDLQLQJFRQWDLQPHQWLVRODWLRQYDOYH

,

7RUXV$UHD 9ROXPH 

1RLQWHUPHGLDWHEUHDNORFDWLRQVZHUHSRVWXODWHGRQWKH5&,&6WHDPOLQHLQWKLV

FRPSDUWPHQW

,

5&,&&RPSDUWPHQW 9ROXPH 

7KHRQO\\66'FRPSRQHQWVLQWKLVFRPSDUWPHQWDUHWKH5&,&HTXLSPHQWZLWKWKH

H[FHSWLRQRIWKH'LYLVLRQ,5+5DQG&RUH6SUD\\SXPSV¶.9SRZHUFDEOHV7KHUH

DUHQREUHDNVRUFULWLFDOFUDFNVLQWKH5&,&FRPSDUWPHQW

,

5HDFWRU:DWHU&OHDQ8S 5:&8 6\\VWHP

7KH5HDFWRU:DWHU&OHDQXSKLJKHQHUJ\\OLQHVDUHORFDWHGLQWKH5:&8FRPSDUWPHQW

9ROXPHV WKHVWHDPFKDVH 9ROXPH WKH0*VHWURRP 9ROXPH WKH

QRUWKZHVWVLGHRIHOHYDWLRQIRRW 9ROXPH DQGWKHQRUWKZHVWVLGHRIHOHYDWLRQ

IRRWRIWKH5HDFWRU%XLOGLQJ 9ROXPH 

7KH5:&8VXSSO\\5(:('DQGWKHUHWXUQOLQH5(:('ZHUHVHLVPLFDOO\\

DQDO\\]HG%UHDNORFDWLRQVZHUHVHOHFWHGEDVHGXSRQWKHVHLVPLFDQDO\\VLVRIWKH

SLSLQJ

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

5:&8$UHD 9ROXPH 

7KHSRVVLEOH5:&8VXSSO\\OLQHSLSHZKLSRUMHWLPSLQJHPHQWWDUJHWVFRQVLVWRI

FRQGXLWVZKLFKVXSSO\\SRZHUWRWKH'LYLVLRQ,,UHDFWRUVDPSOHRXWERDUG

FRQWDLQPHQWYDOYHERWK'LYLVLRQ,,&RUH6SUD\\FRQWDLQPHQWLVRODWLRQYDOYHVDQG

ERWK3ULPDU\\&RQWDLQPHQW$WPRVSKHULF&RQWURO 3&$& YDOYH¶VDLUQLWURJHQ

VXSSO\\OLQHV

7KH3ULPDU\\&RQWDLQPHQW$WPRVSKHULF&RQWURO 3&$& YDOYHDQGRQH&RUH6SUD\\

LVRODWLRQYDOYHDUHQRUPDOO\\FORVHG/RVVRISRZHUWRWKHVHYDOYHVZRXOGFDXVHQR

FKDQJHRIVWDWHDQGFUHDWHQRDGYHUVHFRQFHUQV,QDGGLWLRQWKH'LYLVLRQ,,&RUH

6SUD\\6\\VWHPKDVDFKHFNYDOYHORFDWHGLQVLGHSULPDU\\FRQWDLQPHQWXQDIIHFWHGE\\

WKH+(/%

-HWLPSLQJHPHQWLQWKH5:&8FRPSDUWPHQWFDQFRQVHUYDWLYHO\\WDUJHWDQ\\RIWKH

DERYHYDOYHV7KH5:&8RXWERDUGFRQWDLQPHQWLVRODWLRQYDOYHLVQRWDMHW

LPSLQJHPHQWWDUJHWEHFDXVHRISLSHJHRPHWU\\,VRODWLRQRIWKH5:&8VXSSO\\OLQH

5(:('LVDVVXUHGVLQFHWKHWHUPLQDOHQGEUHDNFDQQRWWDUJHWWKHRXWERDUG

FRQWDLQPHQWLVRODWLRQYDOYH02RUWKHFDEOLQJWRWKHYDOYH7KHUHIRUHHYHQ

ZLWKDVLQJOHDFWLYHIDLOXUHWRHLWKHUFRQWDLQPHQWLVRODWLRQYDOYHRQOLQH5(:

('LVRODWLRQRIWKHEUHDNLVDFFRPSOLVKHGZLWKWKHUHPDLQLQJFRQWDLQPHQW

LVRODWLRQYDOYH

5HGXQGDQWYDOYHVLQVLGHWKH3ULPDU\\&RQWDLQPHQWRUORFDWHGRXWVLGHWKLV

FRPSDUWPHQWPLWLJDWHDQ\\FRQFHUQVRQORVVRIWKHDERYHFRPSRQHQWV7KHDLU

VXSSO\\WRWKH3&$&LVRODWLRQYDOYHV$2DQG$2ZDVXSJUDGHGDQG

KDUGHQHGDJDLQVWSRVWXODWHGFULWLFDOFUDFNV)RUWKHDIIHFWHGYDOYHVVDIH

VKXWGRZQFDQEHDFFRPSOLVKHGXVLQJWKH'LYLVLRQ,HTXLSPHQWDQGWKH+3&,

6\\VWHP6XIILFLHQWUHGXQGDQF\\H[LVWVWREHDEOHWRVKXWGRZQWKHXQLWDVVXPLQJD

VLQJOHDFWLYHIDLOXUH

&RPSDUWPHQWIORRGLQJZRXOGQRWEHDSUREOHPVLQFHQRRWKHU66'HTXLSPHQW

ZRXOGEHDGYHUVHO\\DIIHFWHGE\\IORRGLQJRWKHUWKDQWKH66'HTXLSPHQWGLUHFWO\\

DIIHFWHGE\\SLSHZKLSRUMHWLPSLQJHPHQW(QYLURQPHQWDOHIIHFWVDUHHYDOXDWHGLQ

WKH01*3(QYLURQPHQWDO4XDOLILFDWLRQ (4 SURJUDPEDVHGRQWKHEUHDNFDVHV

LGHQWLILHGLQWKLV$SSHQGL[%RXQGLQJSURILOHVIRUHQYLURQPHQWDOFRQGLWLRQVDUH

LGHQWLILHG7KHHQYLURQPHQWDOFRQGLWLRQVLQFOXGHFRPSDUWPHQWSUHVVXUL]DWLRQ

KHDWXSDQGIORRGLQJHIIHFWV

,

0*6HW5RRP 9ROXPH 

7KHUHDUHQRSRVWXODWHGEUHDNVRUFUDFNVLQWKLVDUHD7KH5:&8UHWXUQSLSLQJ

RXWVLGHWKH5:&8FRPSDUWPHQWLVVHLVPLFDOO\\DQDO\\]HGLQDFFRUGDQFHZLWKWKH

FULWHULDGHILQHGLQ6HFWLRQ,  7KHUHDUHQRSRVWXODWHGLQWHUPHGLDWH5:&8

+(/%VRUFULWLFDOFUDFNVRXWVLGHWKH5:&8FRPSDUWPHQW

,

5HDFWRU%XLOGLQJ)RRW(OHYDWLRQ1RUWKZHVW$UHD 9ROXPH 

7KHUHDUHQRSRVWXODWHGEUHDNVRUFUDFNVLQWKLVDUHD7KHUHDUHQRSRVWXODWHG

LQWHUPHGLDWH5:&8+(/%VRUFUDFNVRXWVLGHWKH5:&8FRPSDUWPHQWDV

LGHQWLILHGLQ,

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

5HDFWRU%XLOGLQJ2SHQ$UHD)RRW(OHYDWLRQ:HVW6LGH 9ROXPH 

7KHUHDUHQRSRVWXODWHGSLSHEUHDNVRUFUDFNVLQWKLVDUHD7KHUHDUHQRSRVWXODWHG

LQWHUPHGLDWH5:&8+(/%VRUFUDFNVRXWVLGHWKH5:&8FRPSDUWPHQWDV

LGHQWLILHGLQ,

,

0DLQ6WHDP&KDVH 9ROXPH 

7KHUHDUHQRSLSHZKLSWDUJHWVIRU66'LQWKLVDUHD$Q\\RWKHUFRQFHUQVLQWKLVDUHD

DUHERXQGHGE\\RWKHUODUJHUSLSHVGLVFXVVHGLQ6HFWLRQV,,DQG

,

6DIHVKXWGRZQZRXOGEHDFFRPSOLVKHGLQWKHPDQQHUGHVFULEHGLQ6HFWLRQ

,ZLWKSRWHQWLDOO\\HLWKHU+3&,RU5&,&QRWDYDLODEOH

,

&RUH6SUD\\6\\VWHP

$VLQGLFDWHGLQ,WKHUHDUHQRSRVWXODWHGEUHDNORFDWLRQVIRUWKLVV\\VWHP

,

5HVLGXDO+HDW5HPRYDO6\\VWHP

$VLQGLFDWHGLQ,WKHUHDUHQRSRVWXODWHGEUHDNORFDWLRQVIRUWKLVV\\VWHP

,

+3&, :DWHU 6\\VWHP

7KHKLJKHQHUJ\\SRUWLRQRIWKLVV\\VWHPLVORFDWHGHQWLUHO\\ZLWKLQWKHPDLQVWHDPFKDVH

9ROXPH 7KHHQYLURQPHQWDOHIIHFWVRIWKLVSRVWXODWHG+(/%DUHERXQGHGE\\WKH

)HHGZDWHUOLQHEUHDNLQWKHVWHDPFKDVH

,

5&,& :DWHU 6\\VWHP

7KHKLJKHQHUJ\\SRUWLRQRIWKLVV\\VWHPLVORFDWHGHQWLUHO\\ZLWKLQWKHPDLQVWHDPFKDVH

9ROXPH 7KHHQYLURQPHQWDOHIIHFWVRIWKLVSRVWXODWHG+(/%DUHERXQGHGE\\WKH

)HHGZDWHUOLQHEUHDNLQWKHVWHDPFKDVH

,

6WDQGE\\/LTXLG&RQWURO

/LQH&+'&IURPFRQWDLQPHQWSHQHWUDWLRQ;WRFKHFNYDOYH;3LVQRW

URXWHGLQWKHYLFLQLW\\RIDQ\\VDIHVKXWGRZQFRPSRQHQWV$QLQERDUGFKHFNYDOYHZLOO

OLPLWDQ\\HQHUJ\\UHOHDVHDQGEHFDXVHRIWKHVPDOOYROXPHRIZDWHUFRQWDLQHG

EHWZHHQWKHLQERDUGFRQWDLQPHQWFKHFNYDOYHDQGYDOYH;3FRPSDUWPHQW

9ROXPH SUHVVXUL]DWLRQDQGIORRGLQJDUHQRWDFRQFHUQEHFDXVHRIDQH[WHQVLYH

GUDLQV\\VWHPDQGDODUJHIUHHYROXPH

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

2II*DV6\\VWHP

7KHVWHDPVXSSO\\OLQH6+3LVORFDWHGLQWKHFRQGHQVHUED\\DUHD 9ROXPH 

DQGWKH6-$(URRP 9ROXPH LQWKH7XUELQH%XLOGLQJ7KHHIIHFWVRISRVWXODWHG

EUHDNVRQWKLVOLQHLQWKHFRQGHQVHUDUHDDUHERXQGHGE\\WKHSRVWXODWHGEUHDNVRQ

RWKHUOLQHVVXFKDV)HHGZDWHUDQG0DLQ6WHDP VHH6HFWLRQV,DQG, 

7KHUHLVQR66'HTXLSPHQWLQWKH6-$(5RRPWREHDIIHFWHGE\\DSLSHZKLSRUMHW

LPSLQJHPHQW3RVWXODWHGEUHDNVRQOLQH6+3DUHERXQGHGE\\RWKHUSRVWXODWHG

+(/%VIRUZKLFKSDWKVWRVDIHVKXWGRZQKDYHEHHQGHPRQVWUDWHG VHH6HFWLRQV

,DQG, $OORWKHUKLJKHQHUJ\\OLQHVLQWKH2IIJDV6\\VWHPDUHORFDWHGLQWKH

2IIJDV6WRUDJHDQG&RPSUHVVRU%XLOGLQJLQZKLFKQRVDIHVKXWGRZQHTXLSPHQWLV

ORFDWHG6LQFHWKHRFFXUUHQFHRID+(/%LQWKLVDUHDFDQKDYHQRLPSDFWRQV\\VWHPV

UHTXLUHGWRPLWLJDWHDFFLGHQWVQRIXUWKHUHYDOXDWLRQVQHHGWREHPDGH

,

=LQF2[LGH,QMHFWLRQ6\\VWHP *(=,3 

7KHSRUWLRQVRIWKH*(=,3V\\VWHPZLWKSRVWXODWHG+(/%VDUHWKHSRUWLRQVQHDU

WKH)HHGZDWHUDQG&RQGHQVDWHOLQHV 9ROXPH LQWKH7XUELQH%XLOGLQJ+RZHYHU

GXHWRWKHSUR[LPLW\\WRWKHSRVWXODWHG)HHGZDWHUDQG&RQGHQVDWH6\\VWHPV+(/%V

DQ\\DGYHUVHHIIHFWVIURPD*(=,3+(/%ZRXOGEHHQYHORSHGE\\DSRVWXODWHG+(/%

RQRQHRIWKH)HHGZDWHURU&RQGHQVDWHOLQHV6LQFHSDWKZD\\VWRVDIHVKXWGRZQKDYH

EHHQGHPRQVWUDWHGIRUWKH)HHGZDWHUDQG&RQGHQVDWHSRVWXODWHG+(/%VWKHVH

VDPHSDWKZD\\VZRXOGH[LVWIRUDPXFKVPDOOHU*(=,3+(/%

,

7DEOHRI6\\VWHP(IIHFWV

7DEOH,VKRZVWKHHIIHFWRIVSHFLILFKLJKHQHUJ\\OLQHEUHDNVE\\YROXPHDQGV\\VWHP

7KLVWDEOHLQFOXGHVWKHUHTXLUHGDX[LOLDU\\V\\VWHPVZKLFKDUHFRQVLGHUHGSRWHQWLDO+(/%

WDUJHWV$Q\\V\\VWHPQRWDIIHFWHGE\\DSRVWXODWHG+(/%LVWREHFRQVLGHUHGDYDLODEOHWR

VXSSRUWVDIHVKXWGRZQ7KHPHDQLQJRIWKHOHWWHUFRGHVXVHGLQWKHWDEOHDUHDVIROORZV

)



3ULPDU\\IDLOXUHDVDGLUHFWUHVXOWRIDOLQHEUHDN

$



6\\VWHPLVXQDIIHFWHGE\\DOLQHEUHDNDQGLVDYDLODEOHWRVXSSRUW

VDIHVKXWGRZQ

8



7KHV\\VWHPLVXQDYDLODEOHGXHWRWKHIDLOXUHRIDUHTXLUHGIXQFWLRQ

RUFRPSRQHQWDVVRFLDWHGZLWKDQRWKHUV\\VWHP





0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,

/RFDWLRQRI+LJK(QHUJ\\6\\VWHPVDQG6DIH6KXWGRZQ(TXLSPHQWE\\9ROXPH



/2&$7,212)+,*+(1(5*<6<67(06$1'6$)(6+87'2:1(48,30(17%<92/80( 5($&725%8,/',1* 

3$*(2)

+,*+(1(5*<6<67(0

92/80( 6((3$*()25$,7,21$/92/80(6 





































0$,167($0

²

²

²

²

²

²

²

²

²

²

+(%&

²

²

²

²

²

²

²

)((':$7(5

²

²

²

²

²

²

²

²

²

²

+(%&

²

²

²

²

²

²

²

&21'(16$7(

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

+3&, 67($0 

²

²

²

²

²

²

²

²

²

²

+(%&

²

²

²

²

²

+(&

²

5&,& 67($0 

²

²

²

²

²

²

²

²

²

²

+(%&

²

²

²

²

²

+(&

²

5($&725:$7(5&/($183

²

²

²

²

²

²

²

²

²

+(

+(%&

²

²

+(%&

²

²

²

+(

&25(635$<

²

²

²

²

+(

²

²

²

²

²

²

²

²

+(

²

²

²

²

5(6,'8$/+($75(029$/

²

²

²

+(

²

²

²

²

²

²

²

+(

²

²

²

²

²

²

+3&, ,1-(&7,21 

²

²

²

²

²

²

²

²

²

²

+(%&

²

²

²

²

²

²

²

5&,& ,1-(&7,21 

²

²

²

²

²

²

²

²

²

²

+(%&

²

²

²

²

²

²

²

67$1'%</,48,'&21752/

²

²

²

+(%

²

²

²

²

²

²

²

²

²

²

²

²

²

²

2))*$6

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

&5'6<67(0

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

  • (=,3

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

,167580(17$1'6$03/(/,1(6

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

²

'2(692/80(&217$,16$)(

6+87'2:1(48,30(17"

<(6

<(6

<(6

<(6

<(6

<(6

<(6

<(6

<(6

<(6

<(6

<(6

<(6

<(6

<(6

<(6

<(6

<(6





 6((6(&7,21,



0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,/RFDWLRQRI+LJK(QHUJ\\6\\VWHPVDQG6DIH6KXWGRZQ(TXLSPHQWE\\9ROXPH

/2&$7,212)+,*+(1(5*<6<67(06$1'6$)(6+87'2:1(48,30(17%<

92/80( 785%,1(%8,/',1* 

3$*(2)

+,*+(1(5*<6<67(0

92/80(













0$,167($0

²

²

²

+(%&

+(%

+(%&

)((':$7(5

+(%

+(&

+(

+(%&

²

+(%&

&21'(16$7(

+(%

+(

+(

+(%&

²

²

+3&, 67($0 

²

²

²

²

²

²

5&,& 67($0 

²

²

²

²

²

²

5($&725:$7(5&/($183

²

²

²

²

²

²

&25(635$<

²

²

²

²

²

²

5(6,'8$/+($75(029$/

²

²

²

²

²

²

+3&, ,1-(&7,21 

²

²

²

²

²

²

5&,& ,1-(&7,21 

²

²

²

²

²

²

67$1'%</,48,'&21752/

²

²

²

²

²

²

2))*$6

²

²

²

+(%

+(%

²

&5'6<67(0

²

²

²

²

²

²

  • (=,3

+(%

²

²

²

²

²

,167580(17$1'6$03/(/,1(6

²

²

²

²

²

²

'2(692/80(&217$,16$)(

6+87'2:1(48,30(17"

<(6

<(6

<(6

<(6

12

12



.(<

²



+,*+(1(5*<3,3,1*2)7+,66<67(0,6127/2&$7(',17+,6&203$570(1725$//+,*+(1(5*<

3,3,1*2)7+,66<67(0+$6%((1(;&/8'('%<&5,7(5,21,6'120,1$/3,3(6,=(2560$//(525

%5($.6$5(1275(48,5('72%($6680('



+(



&217$,16+,*+(1(5*<3,3,1*2)7+,66<67(0 127(;&/8'('%<&5,7(5,21$1',6/$5*(57+$1

120,1$/3,3(6,=( 



+(%



&217$,16%5($./2&$7,216)257+(+,*+(1(5*<3,3,1*2)7+,66<67(0



+(&



&217$,16&5,7,&$/&5$&./2&$7,216)257+(+,*+(1(5*<3,3,1*2)7+,66<67(0



+(%&



&217$,16%5($.$1'&5,7,&$/&5$&./2&$7,216)257+(+,*+(1(5*<3,3,1*2)7+,66<67(0

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





7DEOH,

7DEOHRI6\\VWHP(IIHFWV

6<67(0

67($0&+$6(

 

&21'(16(5$5($

 

6-$(

5220

785%,1(%/'*

)(('3803$5($

 

5:&8

&203  

5($&725

%/'*  

785%,1(  

%/'*

.(<

)  35,0$5<)$,/85($6$

',5(&75(68/72)$/,1(

%5($.

$  6<67(0,681$))(&7('%<$

/,1(%5($.$1',6

$9$,/$%/(726833257

6$)(6+87'2:1

8  7+(6<67(0,681$9$,/$%/(

'8(727+()$,/85(2)$

5(48,5(')81&7,2125

&20321(17$662&,$7('

,7+$127+(56<67(0

6$)(6+87'2:16<67(0

² 5($&7,9,7<&21752/

² 5(6725($1'

0$,17$,1539:$7(5

/(9(/

² 539

'(35(6685,=$7,21

² '(&$<+($75(029$/

&217$,10(17

&22/,1*

² $8;,/,$5<6833257



127(6



'(/(7('



'(/(7('



$33/,(6723621/<



0&&$%



',9&217$,10(17635$<

21/<



7+(5($5(1266'7$5*(76

,17+($5($



7+(6596$5(5(63216,%/(

)2553929(535(6685(

3527(&7,21



'(/(7('



'(/(7('

 '(/(7('

 81$9$,/$%/(817,/,62/$7('

)5200&&%

 7KRXJKQRWUHTXLUHGVDIH

VKXWGRZQHTXLSPHQW5&,&LI

DYDLODEOHFRXOGEHXVHG

0$,167($0

36

+3&,

36

5&,&

36

)((':$7(5

5:&8

5(:

&21'(16$7(

&$

&21'(16$7(

&%

)((':$7(5

67($0

%<3$66

36

0$,167($0

36

0$,167($0

36

&21'(16$7(

&%

&21'(16$7(

&$

)((':$7(5

):$

)((':$7(5

):%

5(:

5(:

6%/&

&+

0$,167($0

36

)HHG:DWHU

+3&,





$

)

)

)

8

$

$

$

)

$

$

$

$

$

$

$

$

$

$

5&,&  



$

$

)

)

8

$

$

$

$

$

$

8

8

8

8

$

$

$

$

6596





$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

5+5/3&,',9



$

$

$

$

$

8

8

8

8

8

8

8

8

8

8

$

$

$

8

5+5/3&,',9



$

$

$

$

$

8

8

8

8

8

8

8

8

8

8

$

$

$

8

5+563&',9



$

$

$

$

$

8

8

8

8

8

8

8

8

8

8

$

$

$

8

5+563&',9



$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

5+56'&',9



$

$

$

$

$

8

8

8

8

8

8

8

8

8

8

$

$

$

8

5+56'&',9



$

$

$

$

$

8

8

8

8

8

8

8

8

8

8

)

$

$

8

5+56(59,&(:$7(5',9



$

$

$

$

$

8

8

8

8

)

8

8

8

8

8

$

$

$

8

5+56(59,&(:$7(5',9



$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

&25(635$<',9





$

$

$

$

$

8

8

8

8

8

8

8

8

8

8

$

$

$

8

&25(635$<',9





)

(0(5*(1&<6(59,&(

$7(5',9



$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

(0(5*(1&<6(59,&(

$7(5',9



$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

(0(5*(1&<32:(5',9



$

$

$

$

$

)

)

)

)

)

)

)

)

)

)

$

$

$

)

(0(5*(1&<32:(5',9



$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

536&21752/52'9$/9(6

&21752/52'6



$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

+9$&



',9

$

$

$

$

$

)

)

)

)

)

)

)

)

)

)

$

$

$

)

(&&65220

',9

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$

$



































































































0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





,

5HIHUHQFHV



1RWXVHG



/HWWHUIURP$*LDPEXVVR'HSXW\\'LUHFWRUIRU5HDFWRU3URMHFWV$(&WR1RUWKHUQ

6WDWHV3RZHU&RPSDQ\\6XEMHFW+LJK(QHUJ\\%UHDNV2XWVLGHRIWKH&RQWDLQPHQW

'HFHPEHUSOXV(UUDWDGDWHG-DQXDU\\5ROO%OLS



6WDQGDUG5HYLHZ3ODQ3ODQW'HVLJQIRU3URWHFWLRQ$JDLQVW3RVWXODWHG3LSLQJ

)DLOXUHVLQ)OXLG6\\VWHPV2XWVLGH&RQWDLQPHQW5HY-XO\\



6WDQGDUG5HYLHZ3ODQ'HWHUPLQDWLRQRI5XSWXUH/RFDWLRQVDQG'\\QDPLF

(IIHFWV$VVRFLDWHGZLWKWKH3RVWXODWHG5XSWXUHRI3LSLQJ5HY-XO\\



1RWXVHG



8QLWHG6WDWHV$WRPLF(QHUJ\\&RPPLVVLRQ6DIHW\\(YDOXDWLRQE\\WKH'LUHFWRUDWHRI

/LFHQVLQJ'RFNHW1R0RQWLFHOOR1XFOHDU*HQHUDWLQJ3ODQW³$QDO\\VLVRIWKH

&RQVHTXHQFHVRI+LJK(QHUJ\\3LSLQJ)DLOXUHV2XWVLGH&RQWDLQPHQW'-XO\\

5ROO*2%OLS



$16,$16$PHULFDQ1DWLRQDO6WDQGDUG'HVLJQ%DVLVIRU3URWHFWLRQRI

/LJKW:DWHU1XFOHDU3RZHU3ODQWV$JDLQVW(IIHFWVRI3RVWXODWHG3LSH5XSWXUH

'HFHPEHU



163 (&:DUG OHWWHUWR$(& $*LDPEXVVR ³0RQWLFHOOR1XFOHDU*HQHUDWLQJ3ODQW

(3RVWXODWHG3LSH)DLOXUHV2XWVLGH&RQWDLQPHQW''RFNHW1RGDWHG

6HSWHPEHUZLWKDWWDFKPHQW³3RVWXODWHG3LSH)DLOXUHV2XWVLGH

&RQWDLQPHQW'$XJXVW5ROO*2%OLS5ROO%OLS



15&1552IILFH,QVWUXFWLRQ³&RQWURORI/LFHQVLQJ%DVHVIRU2SHUDWLQJ5HDFWRUV'

/,&5HYLVLRQ-DQXDU\\

 163 '00XVROI OHWWHUWR15&³)DLOXUHWR3URYLGH+LJK(QHUJ\\/LQH%UHDN

3URWHFWLRQIRUWKH7XUELQH%XLOGLQJ3LSH&KDVH'GDWHG$SULO

 187(&+(QJLQHHULQJ5HSRUW1635HYLVLRQ³5HYLHZRI+LJK(QHUJ\\/LQH

$QDO\\VLVIRUWKH0RQWLFHOOR1XFOHDU*HQHUDWLQJ6WDWLRQ'-XQH

 163OHWWHUWR7HUU\\0D[H\\6XEMHFW(YDOXDWLRQRI5+53UHVVXUHDQG7HPSHUDWXUH

,QFUHDVHIRU(QYLURQPHQWDO4XDOLILFDWLRQ,PSDFW-XQH

 15& 50%HUQHUR *HQHULF/HWWHU³6DIHW\\&RQFHUQV$VVRFLDWHGZLWK3LSH

%UHDNVLQWKH%:56FUDP6\\VWHP'-DQXDU\\

 6FUDP'LVFKDUJH9ROXPH'HVLJQ&KDQJH5HFRPPHQGDWLRQV6,/1R2FWREHU



 6XUYH\\%RRN+LJK(QHUJ\\/LQHVLQ6\\VWHPVFRQVLGHUHGLQ+(/%$QDO\\VLV0D\\

&DOFXODWLRQ5ROO%OLS$5061XPEHU&

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





 6XUYH\\6KHHWVDQG6XUYH\\1RWHVIRU,GHQWLILHG1RQ%HFKWHO+LJK(QHUJ\\/LQHV-XQH

&DOFXODWLRQ5ROO%OLS$5061XPEHU&

 1XWHFK&DOFXODWLRQ163³'HWHUPLQDWLRQRI+LJK(QHUJ\\3LSH/RFDWLRQV

IRUWKH6\\VWHPV%HFKWHO/RRNHGDWLQ'

 'UDZLQJ1'(6:()7(6:³$''LYLVLRQ&URVVWLH3LSLQJ,625HYLVLRQ



 'UDZLQJ1'(6:()7(6:³%''LYLVLRQ&URVVWLH3LSLQJ,625HYLVLRQ



 'HOHWHG

 15& )-0LUDJOLD *HQHULF/HWWHU³5HOD[DWLRQLQ$UELWUDU\\,QWHUPHGLDWH3LSH

5XSWXUH5HTXLUHPHQWV'-XQH

 'HOHWHG

 1XWHFK&DOFXODWLRQ3DFNDJH163'HWHUPLQDWLRQRI³+LJK(QHUJ\\3LSH

%UHDN'/RFDWLRQV-XQH

 /HWWHUIURP'DYLG0XVROI 163 WR'LUHFWRU2IILFHRI1XFOHDU5HDFWRU5HJXODWLRQ

³$GGLWLRQDO,QIRUPDWLRQ5HODWHGWR+LJK(QHUJ\\/LQH%UHDNV$QDO\\VLV''HFHPEHU



 /HWWHUIURP'DYLG0XVROI 163 WR'LUHFWRU2IILFHRI1XFOHDU5HDFWRU5HJXODWLRQ

³5HVROXWLRQRI'HILFLHQFLHVLQ+LJK(QHUJ\\/LQH%UHDN3URWHFWLRQIRUWKH0RQWLFHOOR

3ODQW'-XQH

 1'3ULPDU\\6WHDP6\\VWHP%UHDNDQG&ULWLFDO&UDFN/RFDWLRQV

36(' 36('% 

 1'$GGLWLRQDO3ULPDU\\6WHDP%UHDNDQG&ULWLFDO&UDFN/RFDWLRQV

36 

 1'$GGLWLRQDO3ULPDU\\6WHDP%UHDNDQG&ULWLFDO&UDFN/RFDWLRQV

36(% 

 1'+3&,6\\VWHP6WHDP/LQH%UHDNDQG&ULWLFDO&UDFN/RFDWLRQV

36(' 

 1'3ULPDU\\6WHDP'UDLQ%UHDNDQG&ULWLFDO&UDFN/RFDWLRQV

'(' '(' 

 1'$GGLWLRQDO3ULPDU\\6WHDP%UHDN/RFDWLRQV 36(' 

 1'$GGLWLRQDO3ULPDU\\6WHDP%UHDN/RFDWLRQV$LUHMHFWRU($

36(' 

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





 1'$GGLWLRQDO3ULPDU\\6WHDP%UHDN/RFDWLRQV$LU(MHFWRU(%

36(' 

 1'0DLQ6WHDP'UDLQ%UHDN/RFDWLRQV '(% 

 1'0DLQ6WHDP(TXDOL]LQJ'UDLQWR&RQGHQVHU%UHDN/RFDWLRQV

'('% 

 1'&RQGHQVDWH6\\VWHP%UHDN/RFDWLRQV &$*% 

 1'&RQGHQVDWH6\\VWHP &RQWLQXHG %UHDNDQG&ULWLFDO&UDFN/RFDWLRQV

&%*% 

 1'&RQGHQVDWH6\\VWHP &RQWLQXHG %UHDN/RFDWLRQV &$(% 

 1'&RQGHQVDWH6\\VWHP &RQWLQXHG %UHDN/RFDWLRQV &%(% 

 1')HHGZDWHU6\\VWHP%UHDNDQG&ULWLFDO&UDFN/RFDWLRQV

):$'((' ):'( 

 1')HHGZDWHU6\\VWHP &RQWLQXHG %UHDN/RFDWLRQV ):%'(

(' 

 1'6WDQGE\\/LTXLG&RQWURO6\\VWHP%UHDN/RFDWLRQV &+'& 

 1')HHGZDWHU6\\VWHP &RQWLQXHG %UHDN/RFDWLRQV)HHGZDWHU+HDWHU

($ ):'( ):$'( 

 1')HHGZDWHU6\\VWHP &RQWLQXHG %UHDN/RFDWLRQV)HHGZDWHU+HDWHU

(% ):'( ):%'( 

 1')HHGZDWHU6\\VWHP &RQWLQXHG %UHDN/RFDWLRQV)HHGZDWHU

5HFLUFXODWLRQOLQHV ):'( 

 1'5HDFWRU)HHG3XPSV3$ 3% ):$'( 

):%'( 

 1'&RQWURO5RG'ULYH%UHDN/RFDWLRQV &5''( 

 1'+3&,,QMHFWLRQ/LQH%UHDNDQG&ULWLFDO&UDFN/RFDWLRQV

7:(' 

 1'5&,&,QMHFWLRQ/LQH%UHDNDQG&ULWLFDO&UDFN/RFDWLRQV ):(' 

 1'5&,&6\\VWHP6WHDP/LQH%UHDNDQG&ULWLFDO&UDFN/RFDWLRQV

36(' 

 1'5HDFWRU:DWHU&OHDQXS6\\VWHP%UHDNDQG&ULWLFDO&UDFN/RFDWLRQV

5(:'&''%' 

0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





 1'5HDFWRU:DWHU&OHDQXS5HWXUQ/LQH%UHDN/RFDWLRQV

5(:'%' 

 1'5HDFWRU:DWHU&OHDQXS6\\VWHP &RQWLQXHG %UHDNDQG&ULWLFDO

&UDFN/RFDWLRQV 5(:'&'%(' 5(:'% 5(:'% 

 1'2II*DV6\\VWHP%UHDN/RFDWLRQV 6+3+1& 

 1'2II*DV6\\VWHP &RQWLQXHG %UHDN/RFDWLRQV 6+3+1& 

 1'2II*DV6\\VWHP%UHDN/RFDWLRQV 6+3+1& 

 1'6WHDP6HDO5HJXODWRU3LSLQJ%UHDN/RFDWLRQV 36 36 

 1'*(=,3 287 6\\VWHP+(/%%UHDN &ULWLFDO&UDFN/RFDWLRQV

*=3 

 15& '&'L,DQQL OHWWHUWR163 '00XVROI ³5HTXHVW)RU$GGLWLRQDO,QIRUPDWLRQ

5HODWHGWR+LJK(QHUJ\\/LQH%UHDNV'GDWHG6HSWHPEHUZLWK5$,HQFORVXUH

 163 '00XVROI OHWWHUWR15&³$GGLWLRQDO,QIRUPDWLRQ5HODWHGWR8SGDWHG+LJK

(QHUJ\\/LQH%UHDN$QDO\\VLV'GDWHG'HFHPEHU

 15& :2/RQJ OHWWHUWR163 703DUNHU ³0RQWLFHOOR+LJK(QHUJ\\/LQH%UHDN

$QDO\\VLV 7$&1R 'GDWHG-XQH

 1630OHWWHU/07 7-2

&RQQRU WR15&GDWHG$XJXVW³0RQWLFHOOR

([WHQGHG3RZHU8SUDWH5HVSRQVHWR15&0HFKDQLFDODQG&LYLO(QJLQHHULQJ

5HYLHZ%UDQFK (0&% 5HTXHVWVIRU$GGLWLRQDO,QIRUPDWLRQV 5$,V GDWHG0DUFK

 7$&1R0' 'GDWHG$XJXVW

 15& 7$%HOW] OHWWHUWR1630 .')LOL 0RQWLFHOOR1XFOHDU*HQHUDWLQJ3ODQW

,VVXDQFHRI$PHQGPHQW1RWR5HQHZHG)DFLOLW\\2SHUDWLQJ/LFHQVH5HJDUGLQJ

([WHQGHG3RZHU8SUDWH 7$&120' GDWHG'HFHPEHU

 (&&DOFXODWLRQ5HY7HPSHUDWXUHDQG$VEXLOW$QDO\\VHVRI&5'

DQG5:&83LSLQJ7HUPLQDO(QG'HILQLWLRQV

 &KDQJH5HTXHVW86$5$SSHQGL[,+(/%5HYLVLRQ

 15&6(5IRU3RZHU5HUDWH$PHQGPHQWGDWHG6HSWHPEHU5ROO

%OLS

 01*3/LFHQVH$PHQGPHQW5HTXHVWIRU5HUDWH5HYLVLRQGDWHG'HFHPEHU

5ROO%OLS







0217,&(//283'$7('6$)(7<$1$/<6,65(3257

86$5,

$33(1',;,

(9$/8$7,212)+,*+(1(5*</,1(%5($.6

2876,'(&217$,10(17

5HYLVLRQ

3DJHRI





),*85(6



LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ
LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ





LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ
LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ





LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ
LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ





LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ
LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ





LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ
LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ





LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ
LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ





LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ
LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ





LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ
LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ





LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ
LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ



LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ
LWKKHOG6HFXULW\\5HODWHG,QIRUPDWLRQ