From:

Cruz, Holly To:

Thomas Eiden Cc:

Balazik, Michael; Michael Grochowski

Subject:

Revised PDC TR RAIs Uploaded to Box Date:

Friday, September 02, 2022 12:45:00 PM

Thomas,

Ive uploaded the revised PDC TR RAIs to BOX, along with some staff observations. As discussed, this revision resulted in the reduction in the overall number of RAIs. However, the main question that I believe Atomic Alchemy would like to discuss with the staff related to burnable poison, is still on the revised list (RAI 11). Weve scheduled some time to discuss further in a clarification call on Tuesday, 9/6/22, at 4pm (eastern). Please let me know if you have any questions in the meantime.

Thanks again,

Holly

From: Cruz, Holly Sent: Friday, July 22, 2022 4:06 PM To: Thomas Eiden <thomas.eiden@atomicalchemy.us>

Cc: Balazik, Michael <Michael.Balazik@nrc.gov>; Michael Grochowski

<michael.grochowski@atomicalchemy.us>

Subject:

Draft PDC TR RAIs Uploaded to Box

Thomas,

Ive uploaded the PDC TR Draft RAIs to Box under the folder: NRC Documents>PDC TR.

Please take a look when you get a chance to make sure it uploaded successfully. Once weve verified youre able to view, please let us know if you have any questions or need a clarification call before we issue formally. There also appears to be a folder titled, Assets, in the Atomic Alchemy Data Room. We havent opened it, but wanted to make you aware, should it be something we shouldnt have permission to view.

Thanks again,

Holly

Holly Cruz, Senior Project Manager Non-power Production and Utilization Facility Licensing Branch (UNPL)

Division of Advanced Reactors and Non-power Production and Utilization Facilities Office of Nuclear Reactor Regulation, USNRC Phone: (301) 415-1053 Location: O-6A56; M/S: O-6A51 email: holly.cruz@nrc.gov

From: Thomas Eiden <noreply@box.com>

Sent: Wednesday, July 06, 2022 3:39 PM To: Cruz, Holly <Holly.Cruz@nrc.gov>

Subject:

[External_Sender] Thomas Eiden has invited you to work together in "NRC - Atomic Alchemy Data Room" folder on Box

Thomas Eiden wants to work with you on NRC - Atomic Alchemy Data Room NRC - Atomic Alchemy Data Room "Testing the data room functionality to be able to efficiently share information."

Go to Folder

Get our app to view this on mobile

© 2022 l 900 Jefferson Avenue, Redwood City, CA 94063, USA About Boxl Edit Notification Settingsl Privacy Policy