Text
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 165 Appendix B-100U 2-31 Table 2.4-3 (Page 1 of 8)
PWR Fuel Assembly Burnup and Cooling Time-Dependent Coefficients Limits (ZR-Clad Fuel)
Minimum Cooling Time (years)
Maximum Allowable Burnup, MWd/mtU MPC-24/24E/24EF 1.0 5,000 1.4 15,000 1.8 25,000 2.0 35,000 2.2 40,000 2.4 45,000 2.6 50,000 2.8 55,000 3.0 60,000 4.0 69,000 5.0 75,000 MPC-32/32F 1.0 5,000 1.4 10,000 1.8 20,000 2.0 25,000 2.2 30,000 2.4 35,000 2.6 40,000 3.0 45,000 4.0 60,000 5.0 69,000 Holtec Letter 5014951 Attachment 7 Page 1 of 2
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 165 Appendix B-100U 2-39 Table 2.4-4 (Page 1 of 10)
BWR Fuel Assembly Burnup and Cooling Time-Dependent Coefficients Limits (ZR-Clad Fuel)
Minimum Cooling Time (years)
Maximum Allowable Burnup, MWd/mtU MPC-68/68FF/68M 1.0 10,000 1.2 15,000 1.4 20,000 2.0 25,000 2.2 30,000 2.4 35,000 2.6 40,000 3.0 50,000 4.0 62,000 5.0 65,000 6.0 70,000 Holtec Letter 5014951 Attachment 7 Page 2 of 2