Atlanta Corporate Headquarters: 3930 East Jones Bridge Road, Norcross, Georgia 30092 USA Phone 770-447-1144, Fax 770-447-1797, www.nacintl.com July 2022 Docket No. 72-1031 MAGNASTOR (Modular Advanced Generation Nuclear All-purpose STORage)
FINAL SAFETY ANALYSIS REPORT Amendment 11 Supplement Revision 22B to ED20220101 Page 1 of 3 List of Changes for MAGNASTOR FSAR, Amendment 11 Supplement Revision 22B (Docket No 72-1031)
NAC International July 2022 to ED20220101 Page 2 of 3 List of Changes for the MAGNASTOR FSAR, Revision 22B Note: The List of Effective Pages and the Chapter Table of Contents, List of Figures, and List of Tables have been revised accordingly to reflect the list of changes detailed below.
Chapter 1
No changes.
Chapter 2
No changes.
Chapter 3
No changes.
Chapter 4
No changes.
Chapter 5
No changes.
Chapter 6
No changes.
Chapter 7
No changes.
Chapter 8
No changes.
Chapter 9
No changes.
Chapter 10
Page 10.2-3, modified the sixth row of Table 10.2-1 where indicated.
to ED20220101 Page 3 of 3 Chapter 11 No changes.
Chapter 12 No changes.
Chapter 13 No changes.
Chapter 14 No changes Chapter 15 No changes to ED20220101 Page 1 of 1 FSAR Changed Pages and LOEP Docket No. 72-1031 MAGNASTOR FSAR, Amendment 11 Supplement Revision 22B (Docket No 72-1031)
NAC International July 2022
Atlanta Corporate Headquarters: 3930 East Jones Bridge Road, Norcross, Georgia 30092 USA Phone 770-447-1144, Fax 770-447-1797, www.nacintl.com July 2022 Docket No. 72-1031 MAGNASTOR (Modular Advanced Generation Nuclear All-purpose STORage)
FINAL SAFETY ANALYSIS REPORT Revision 22B
MAGNASTOR System FSAR July 2022 Docket No. 72-1031 Revision 22B List of Effective Pages Page 1 of 7 Chapter 1 Page 1-i............................. Revision 20A Page 1-1................................. Revision 1 Page 1.1-1 thru 1.1-6......... Revision 20A Page 1.2-1 thru 1.2-2......... Revision 20A Page 1.3-1.............................. Revision 5 Page 1.3-2......................... Revision 20A Page 1.3-3.............................. Revision 5 Page 1.3-4 thru 1.3-10....... Revision 20A Page 1.3-11 thru 1.3-13.......... Revision 5 Page 1.3-14 thru 1.3-21..... Revision 20A Page 1.4-1......................... Revision 20A Page 1.5-1.............................. Revision 9 Page 1.6-1.............................. Revision 9 Page 1.6-2.............................. Revision 0 Page 1.7-1.............................. Revision 0 Page 1.7-2.............................. Revision 2 Page 1.8-1 thru 1.8-2......... Revision 20A 26 drawings (see Section 1.8)
Chapter 2 Page 2-i thru 2-ii............... Revision 20A Page 2-1............................ Revision 20A Page 2.1-1.............................. Revision 5 Page 2.1-2.............................. Revision 0 Page 2.1-3.............................. Revision 5 Page 2.1-4.............................. Revision 8 Page 2.1-5.............................. Revision 5 Page 2.2-1......................... Revision 20A Page 2.2-2.......................... Revision 21B Page 2.2-3 thru 2.2-4......... Revision 20A Page 2.2-5.......................... Revision 21B Page 2.2-6 thru 2.2-7......... Revision 20A Page 2.2-8.......................... Revision 21B Page 2.2-9......................... Revision 20A Page 2.3-1 thru 2.3-4.............. Revision 0 Page 2.3-5.............................. Revision 5 Page 2.3-6 thru 2.3-8.............. Revision 0 Page 2.4-1.............................. Revision 0 Page 2.4-2.............................. Revision 2 Page 2.4-3 thru 2.4-4.............. Revision 5 Page 2.4-5.............................. Revision 0 Page 2.4-6.............................. Revision 5 Page 2.4-7.............................. Revision 9 Page 2.5-1.............................. Revision 0 Page 2.6-1 thru 2.6-2.............. Revision 0 Chapter 3 Page 3-i.................................. Revision 6 Page 3-ii thru 3-x.............. Revision 20A Page 3-1................................. Revision 0 Page 3.1-1.............................. Revision 9 Page 3.1-2.............................. Revision 0 Page 3.1-3 thru 3.1-6......... Revision 20A Page 3.2-1 thru 3.2-6......... Revision 20A Page 3.3-1.............................. Revision 0 Page 3.4-1.............................. Revision 2 Page 3.4-2......................... Revision 20A Page 3.4-3.............................. Revision 6 Page 3.4-4.............................. Revision 1 Page 3.4-5.............................. Revision 5 Page 3.4-6 thru 3.4-14............ Revision 3 Page 3.4-15....................... Revision 20A Page 3.4-16 thru 3.4-42.......... Revision 3 Page 3.4-43 thru 3.4-57.......... Revision 9 Page 3.4-58 thru 3.4-77..... Revision 20A Page 3.5-1.............................. Revision 5 Page 3.5-2 thru 3.5-4.............. Revision 9 Page 3.5-5 thru 3.5-26............ Revision 6 Page 3.5-27....................... Revision 20A Page 3.5-28 thru 3.5-30.......... Revision 8 Page 3.6-1 thru 3.6-2.............. Revision 5 Page 3.6-3 thru 3.6-4.............. Revision 9 Page 3.6-5 thru 3.6-19............ Revision 6 Page 3.7-1.............................. Revision 5 Page 3.7-2 thru 3.7-3.............. Revision 9 Page 3.7-4 thru 3.7-56............ Revision 6 Page 3.7-57....................... Revision 20A Page 3.7-58............................ Revision 6 Page 3.7-59 thru 3.7-61.......... Revision 8 Page 3.7-62 thru 3.7-64.......... Revision 6 Page 3.7-65............................ Revision 8 Page 3.7-66............................ Revision 6 Page 3.7-67 thru 3.7-68.......... Revision 8 Page 3.7-69............................ Revision 6
MAGNASTOR System FSAR July 2022 Docket No. 72-1031 Revision 22B List of Effective Pages (contd)
Page 2 of 7 Page 3.7-70 thru 3.7-72.......... Revision 8 Page 3.7-72 thru 3.7-81.......... Revision 6 Page 3.7-73 thru 3.7-79.......... Revision 6 Page 3.7-80............................ Revision 8 Page 3.7-81............................ Revision 6 Page 3.8-1 thru 3.8-10............ Revision 0 Page 3.9-1.............................. Revision 0 Page 3.9-2.............................. Revision 1 Page 3.9-3.............................. Revision 9 Page 3.10-1............................ Revision 0 Page 3.10.1-1......................... Revision 5 Page 3.10.1-2 thru 3.10.1-4.... Revision 2 Page 3.10.1-5......................... Revision 1 Page 3.10.1-6 thru 3.10.1-32.. Revision 5 Page 3.10.2-1 thru 3.10.2-6.... Revision 4 Page 3.10.2-7 thru 3.10.2-44..................... Revision 20A Page 3.10.3-1 thru 3.10.3-2.... Revision 8 Page 3.10.3-3......................... Revision 0 Page 3.10.3-4 thru 3.10.3-23.. Revision 1 Page 3.10.3-24....................... Revision 8 Page 3.10.3-25 thru 3.10.3-38 Revision 1 Page 3.10.4-1 thru 3.10.4-2.... Revision 1 Page 3.10.4-3 thru 3.10.4-9.... Revision 0 Page 3.10.4-10....................... Revision 1 Page 3.10.4-11 thru 3.10.4-14 Revision 0 Page 3.10.5-1......................... Revision 1 Page 3.10.5-2......................... Revision 2 Page 3.10.5-3......................... Revision 9 Page 3.10.5-4 thru 3.10.5-13..................... Revision 20A Page 3.10.6-1 thru 3.10.6-2.... Revision 5 Page 3.10.6-3......................... Revision 4 Page 3.10.6-4 thru 3.10.6-6.... Revision 5 Page 3.10.6-7 thru 3.10.6-10.. Revision 4 Page 3.10.6-11 thru 3.10.6-13 Revision 2 Page 3.10.6.14 thru 3.10.6-16 Revision 4 Page 3.10.6-17 thru 3.10.6-18 Revision 2 Page 3.10.6-19....................... Revision 4 Page 3.10.6-20 thru 3.10.6-21 Revision 2 Page 3.10.6-22 thru 3.10.6-34 Revision 4 Page 3.10.7-1 thru 3.10.7-2.... Revision 0 Page 3.10.8-1......................... Revision 4 Page 3.10.8-2......................... Revision 2 Page 3.10.8-3 thru 3.10.8-8.... Revision 0 Page 3.10.9-1......................... Revision 6 Page 3.10.9-2......................... Revision 4 Page 3.10.9-3 thru 3.10.9-11.. Revision 0 Page 3.10.10-1 thru 3.10.10-8 Revision 5 Page 3.11.1........................ Revision 20A Page 3.11.1-1.................... Revision 20A Page 3.11.2-1 thru 3.11.2-26..................... Revision 20A Page 3.11.3-1 thru 3.11.3-27..................... Revision 20A Page 3.11.3-28................... Revision 21B Page 3.11.3-29.................. Revision 20A Chapter 4 Page 4-i.................................. Revision 9 Page 4-ii............................ Revision 20A Page 4-iii................................ Revision 9 Page 4-iv thru 4-v............... Revision 21B Page 4-vi thru 4-vii........... Revision 20A Page 4-1................................. Revision 0 Page 4.1-1 thru 4.1-4......... Revision 20A Page 4.1-5 thru 4.1-8.............. Revision 7 Page 4.2-1.............................. Revision 0 Page 4.3-1.............................. Revision 0 Page 4.4-1......................... Revision 20A Page 4.4-2 thru 4.4-3.............. Revision 5 Page 4.4-4 thru 4.4-7.............. Revision 8 Page 4.4-8 thru 4.4-10............ Revision 5 Page 4.4-11............................ Revision 7 Page 4.4-12....................... Revision 20A Page 4.4-13 thru 4.4-20.......... Revision 7 Page 4.4-21 thru 4.4-22.......... Revision 9 Page 4.4-23 thru 4.4-25.......... Revision 7 Page 4.4-26 thru 4.4-27.......... Revision 8 Page 4.4-28 thru 4.4-31.......... Revision 7 Page 4.4-32............................ Revision 9 Page 4.4-33 thru 4.4-36.......... Revision 8 Page 4.4-37 thru 4.4-63.......... Revision 7 Page 4.4-64............................ Revision 8 Page 4.4-65 thru 4.4-71.......... Revision 7 Page 4.5-1......................... Revision 20A Page 4.5-2.............................. Revision 7 Page 4.5-3 thru 4.5-4.............. Revision 9
MAGNASTOR System FSAR July 2022 Docket No. 72-1031 Revision 22B List of Effective Pages (contd)
Page 3 of 7 Page 4.6-1......................... Revision 20A Page 4.6-2 thru 4.6-4.............. Revision 7 Page 4.7-1.............................. Revision 0 Page 4.7-2.............................. Revision 9 Page 4.8-1.............................. Revision 0 Page 4.8.1-1 thru 4.8.1-10...... Revision 0 Page 4.8.2-1 thru 4.8.2-8........ Revision 0 Page 4.8.3-1 thru 4.8.3-2........ Revision 0 Page 4.8.3-3 thru 4.8.3-4........ Revision 1 Page 4.8.3-5........................... Revision 0 Page 4.8.3-6 thru 4.8.3-9........ Revision 1 Page 4.9-1.............................. Revision 9 Page 4.9.1-1......................... Revision 10 Page 4.9.2-1 thru 4.9.2-4...... Revision 10 Page 4.9.3-1........................... Revision 8 Page 4.9.3-2......................... Revision 10 Page 4.9.3-3........................... Revision 3 Page 4.9.4-1........................... Revision 8 Page 4.10-1............................ Revision 9 Page 4.10.1-1 thru 4.10.1-5.... Revision 9 Page 4.10.2-1 thru 4.10.2-5.... Revision 9 Page 4.11-1........................ Revision 21B Page 4.11.1-1 thru 4.11.1-49...................... Revision 21B Page 4.11.2-1..................... Revision 21B Page 4.11.2-2.................... Revision 20A Page 4.11.2-3 thru 4.11.2-4........................ Revision 21B Page 4.11.2-5 thru 4.11.2-6....................... Revision 20A Page 4.11.2-7 thru 4.11.2-8........................ Revision 21B Page 4.11.2-9 thru 4.11.2-11..................... Revision 20A Page 4.11.2-12................... Revision 21B Page 4.11.3-1 thru 4.11.3-2........................ Revision 21B Page 4.11.4-1 thru 4.11.4-3........................ Revision 21B Page 4.11.5-1..................... Revision 21B Chapter 5 Page 5-i............................. Revision 20A Page 5-ii................................. Revision 9 Page 5-iii........................... Revision 20A Page 5-iv................................ Revision 5 Page 5-v................................. Revision 1 Page 5-vi................................ Revision 5 Page 5-vii............................... Revision 8 Page 5-viii.............................. Revision 5 Page 5-ix................................ Revision 9 Page 5-x thru 5-xi.............. Revision 20A Page xii thru xiv..................... Revision 9 Page xv.............................. Revision 20A Page 5-1 thru 5-2............... Revision 20A Page 5.1-1 thru 5.1-13....... Revision 20A Page 5.2-1 thru 5.2-12............ Revision 5 Page 5.3-1 thru 5.3-2.............. Revision 5 Page 5.3-3.............................. Revision 0 Page 5.3-4 thru 5.3-5.............. Revision 1 Page 5.3-6.............................. Revision 0 Page 5.4-1 thru 5.4-5.............. Revision 0 Page 5.5-1.............................. Revision 0 Page 5.5-2 thru 5.5-3.............. Revision 8 Page 5.5-4 thru 5.5-5.............. Revision 5 Page 5.5-6.............................. Revision 0 Page 5.5-7 thru 5.5-10............ Revision 1 Page 5.5-11 thru 5.5-13.......... Revision 0 Page 5.5-14............................ Revision 8 Page 5.5-15............................ Revision 1 Page 5.5-16 thru 5.5-20.......... Revision 5 Page 5.6-1 thru 5.6-2.............. Revision 0 Page 5.6-3.............................. Revision 1 Page 5.6-4.............................. Revision 8 Page 5.6-5 thru 5.6-6.............. Revision 5 Page 5.6-7.............................. Revision 1 Page 5.6-8.............................. Revision 5 Page 5.6-9.............................. Revision 1 Page 5.6-10 thru 5.6-13.......... Revision 0 Page 5.7-1 thru 5.7-2.............. Revision 0 Page 5.7-3.............................. Revision 9 Page 5.8-1.............................. Revision 0 Page 5.8.1-1 thru 5.8.1-4........ Revision 0 Page 5.8.2-1........................... Revision 0 Page 5.8.2-2 thru 5.8.2-5........ Revision 1 Page 5.8.2-6........................... Revision 0 Page 5.8.2-7 thru 5.8.2-13...... Revision 1 Page 5.8.3-1........................... Revision 5
MAGNASTOR System FSAR July 2022 Docket No. 72-1031 Revision 22B List of Effective Pages (contd)
Page 4 of 7 Page 5.8.3-2........................... Revision 1 Page 5.8.3-3........................... Revision 5 Page 5.8.3-4........................... Revision 8 Page 5.8.3-5........................... Revision 5 Page 5.8.3-6 thru 5.8.3-17...... Revision 1 Page 5.8.3-18 thru 5.8.3-19.... Revision 5 Page 5.8.3-20 thru 5.8.3-23.... Revision 1 Page 5.8.3-24 thru 5.8.3-31.... Revision 5 Page 5.8.3-32......................... Revision 8 Page 5.8.3-33......................... Revision 5 Page 5.8.4-1........................... Revision 5 Page 5.8.4-2........................... Revision 7 Page 5.8.4-3 thru 5.8.4-17...... Revision 0 Page 5.8.4-18 thru 5.8.4-29.... Revision 9 Page 5.8.4-30......................... Revision 0 Page 5.8.5-1........................... Revision 5 Page 5.8.5-2 thru 5.8.5-3........ Revision 7 Page 5.8.5-4........................... Revision 8 Page 5.8.5-5 thru 5.8.5-6........ Revision 5 Page 5.8.5-7........................... Revision 0 Page 5.8.5-8 thru 5.8.5-9........ Revision 8 Page 5.8.6-1........................... Revision 7 Page 5.8.6-2 thru 5.8.6-6........ Revision 5 Page 5.8.6-7........................... Revision 7 Page 5.8.7-1 thru 5.8.7-2........ Revision 7 Page 5.8.7-3........................... Revision 0 Page 5.8.7-4........................... Revision 8 Page 5.8.7-5........................... Revision 7 Page 5.8.8-1........................... Revision 8 Page 5.8.8-2 thru 5.8.8-4........ Revision 0 Page 5.8.8-5 thru 5.8.8-12...... Revision 1 Page 5.8.8-13 thru 5.8.8-23.... Revision 0 Page 5.8.8-24 thru 5.8.8-34.... Revision 1 Page 5.8.8-35 thru 5.8.8-56.... Revision 0 Page 5.8.8-57 thru 5.8.8-65.... Revision 5 Page 5.8.8-66 thru 5.8.8-79.... Revision 8 Page 5.8.8-80 thru 5.8.8-115.. Revision 5 Page 5.8.9-1........................... Revision 7 Page 5.8.9-2........................... Revision 0 Page 5.8.9-3 thru 5.8.9-54...... Revision 9 Page 5.8.9-55......................... Revision 1 Page 5.8.9-56......................... Revision 7 Page 5.8.9-57 thru 5.8.9-69.... Revision 9 Page 5.8.10-1 thru 5.8.10-5.... Revision 0 Page 5.8.11-1 thru 5.8.11-3.... Revision 1 Page 5.8.12-1......................... Revision 8 Page 5.8.12-2 thru 5.8.12-16.. Revision 5 Page 5.8.13-1 thru 5.8.13-6.... Revision 5 Page 5.9-1.............................. Revision 7 Page 5.9.1-1........................... Revision 7 Page 5.9.2-1........................... Revision 7 Page 5.9.3-1 thru 5.9.3-5........ Revision 7 Page 5.9.4-1 thru 5.9.4-2........ Revision 7 Page 5.9.5-1 thru 5.9.5-2........ Revision 7 Page 5.9.6-1 thru 5.9.6-4........ Revision 7 Page 5.9.7-1 thru 5.9.7-23...... Revision 7 Page 5.9.8-1........................... Revision 7 Page 5.9.8-2 thru 5.9.8-28...... Revision 9 Page 5.9.9-1 thru 5.9.9-6........ Revision 7 Page 5.10-1............................ Revision 7 Page 5.10.1-1......................... Revision 7 Page 5.10.2-1......................... Revision 7 Page 5.10.3-1 thru 5.10.3-3.... Revision 7 Page 5.10.4-1......................... Revision 7 Page 5.10.5-1 thru 5.10.5-4.... Revision 7 Page 5.10.6-1......................... Revision 7 Page 5.10.6-2 thru 5.10.6-25.. Revision 9 Page 5.11.1-1 thru 5.11.1-6.... Revision 9 Page 5.11.2-1......................... Revision 9 Page 5.11.3-1 thru 5.11.3-4.... Revision 9 Page 5.11.4-1 thru 5.11.4-8.... Revision 9 Page 5.11.5-1 thru 5.11.5-2.... Revision 9 Page 5.11.6-1......................... Revision 9 Page 5.11.7-1 thru 5.11.7-2.... Revision 9 Page 5.11.8-1 thru 5.11.8-11.. Revision 9 Page 5.11.9-1......................... Revision 9 Page 5.11.10-1 thru 5.11.10-10........................ Revision 9 Page 5.11.11-1 thru 5.11.11-41........................ Revision 9 Page 5.12-1....................... Revision 20A Page 5.12.1-1.................... Revision 20A Page 5.12.2-1 thru 5.12.2-4....................... Revision 20A Page 5.12.3-1.................... Revision 20A Page 5.12.4-1 thru 5.12.4-11..................... Revision 20A Page 5.12.5-1.................... Revision 20A
MAGNASTOR System FSAR July 2022 Docket No. 72-1031 Revision 22B List of Effective Pages (contd)
Page 5 of 7 Page 5.12.6-1.................... Revision 20A Page 5.12.7-1.................... Revision 20A Page 5.13-1....................... Revision 20A Page 5.13.1-1 thru 5.13.1-4....................... Revision 20A Page 5.13.2-1 thru 5.13.2-2....................... Revision 20A Page 5.13.3-1 thru 5.13.3-3....................... Revision 20A Page 5.14-1....................... Revision 20A Page 5.14.1-1.................... Revision 20A Page 5.14.2-1.................... Revision 20A Page 5.14.3-1.................... Revision 20A Page 5.14.4-1 thru 5.14.4-10..................... Revision 20A Page 5.14.5-1 thru 5.14.5-3....................... Revision 20A Page 5.14.6-1.................... Revision 20A Page 5.14.7-1.................... Revision 20A Chapter 6 Page 6-i thru 6-vi.............. Revision 20A Page 6-1................................. Revision 0 Page 6.1-1 thru 6.1-19....... Revision 20A Page 6.2-1.............................. Revision 5 Page 6.2-2 thru 6.2-5.............. Revision 0 Page 6.3-1 thru 6.3-3......... Revision 20A Page 6.3-4 thru 6.3-8.............. Revision 0 Page 6.3-9.............................. Revision 2 Page 6.4-1.............................. Revision 0 Page 6.4-2.............................. Revision 2 Page 6.4-3.............................. Revision 5 Page 6.4-4 thru 6.4-7......... Revision 20A Page 6.4-8 thru 6.4-10............ Revision 5 Page 6.4-11....................... Revision 20A Page 6.5-1......................... Revision 20A Page 6.5-2.............................. Revision 0 Page 6.5-3 thru 6.5-4......... Revision 20A Page 6.5-5 thru 6.5-7.............. Revision 0 Page 6.5-8......................... Revision 20A Page 6.6-1......................... Revision 20A Page 6.7-1.............................. Revision 0 Page 6.7.1-1 thru 6.7.1-2........ Revision 5 Page 6.7.1-3........................... Revision 0 Page 6.7.1-4........................... Revision 2 Page 6.7.1-5 thru 6.7.1-37...... Revision 0 Page 6.7.2-1 thru 6.7.2-2........ Revision 0 Page 6.7.2-3........................... Revision 5 Page 6.7.2-4 thru 6.7.2-5........ Revision 0 Page 6.7.3-1 thru 6.7.3-27...... Revision 5 Page 6.7.4-1 thru 6.7.4-26....................... Revision 20A Page 6.7.5-1...................... Revision 20A Page 6.7.5-2 thru 6.7.5-7........ Revision 0 Page 6.7.6-1 thru 6.7.6-4... Revision 20A Page 6.7.6-5........................... Revision 2 Page 6.7.6-6 thru 6.7.6-12....................... Revision 20A Page 6.7.6-13 thru 6.7.6-16.... Revision 2 Page 6.7.6-17 thru 6.7.6-23....................... Revision 20A Page 6.7.6-24......................... Revision 7 Page 6.7.6-25.................... Revision 20A Page 6.7.6-26......................... Revision 2 Page 6.7.6-27 thru 6.7.6-31....................... Revision 20A Page 6.7.7-1 thru 6.7.7-34. Revision 20A Page 6.7.8-1 thru 6.7.8-3........ Revision 5 Page 6.7.8-4........................... Revision 7 Page 6.7.8-5 thru 6.7.8-80...... Revision 5 Page 6.7.8-81 thru 6.7.8-83.... Revision 7 Page 6.7.8-84......................... Revision 5 Page 6.7.8-85 thru 6.7.8-87.... Revision 7 Page 6.7.8-88 thru 6.7.8-89.... Revision 5 Page 6.7.8-90......................... Revision 7 Page 6.7.9-1 thru 6.7.9-9... Revision 20A Page 6.7.10-1 thru 6.7.10-2....................... Revision 20A Chapter 7 Page 7-i................................. Revision 5 Page 7-1................................. Revision 0 Page 7.1-1 thru 7.1-3......... Revision 20A Page 7.1-4.............................. Revision 7 Page 7.1-5.............................. Revision 5 Page 7.1-6.............................. Revision 2 Page 7.2-1.............................. Revision 8 Page 7.2-2.............................. Revision 0
MAGNASTOR System FSAR July 2022 Docket No. 72-1031 Revision 22B List of Effective Pages (contd)
Page 6 of 7 Page 7.3-1.............................. Revision 0 Page 7.4-1.............................. Revision 0 Chapter 8 Page 8-i.................................. Revision 8 Page 8-ii................................. Revision 5 Page 8-1................................. Revision 0 Page 8.1-1.............................. Revision 5 Page 8.1-2......................... Revision 20A Page 8.1-3.............................. Revision 6 Page 8.1-4......................... Revision 20A Page 8.2-1.............................. Revision 1 Page 8.3-1.............................. Revision 5 Page 8.3-2 thru 8.3-8.............. Revision 1 Page 8.3-9 thru 8.3-14............ Revision 5 Page 8.3-15 thru 8.3-16..... Revision 20A Page 8.3-17............................ Revision 5 Page 8.4-1.............................. Revision 0 Page 8.5-1......................... Revision 20A Page 8.5-2.............................. Revision 6 Page 8.6-1.............................. Revision 1 Page 8.6-2 thru 8.6-3.............. Revision 8 Page 8.7-1.............................. Revision 2 Page 8.7-2.............................. Revision 0 Page 8.8-1.............................. Revision 2 Page 8.8-2.............................. Revision 3 Page 8.8-3.............................. Revision 0 Page 8.8-4.............................. Revision 3 Page 8.9-1.............................. Revision 0 Page 8.10-1............................ Revision 0 Page 8.10-2 thru 8.10-3..... Revision 20A Page 8.10-4 thru 8.10-6.......... Revision 1 Page 8.10-7............................ Revision 8 Page 8.11-1 thru 8.11-2.......... Revision 0 Page 8.11-3............................ Revision 8 Page 8.12-1 thru 8.12-2.......... Revision 0 Page 8.12-3....................... Revision 20A Page 8.13-1............................ Revision 8 Page 8.13-2 thru 8.13-6.......... Revision 0 Page 8.13-7............................ Revision 8 Page 8.13-8............................ Revision 6 Page 8.13-9............................ Revision 8 Page 8.13-10 thru 8.13-17...... Revision 6 Page 8.13-18 thru 8.13-40...... Revision 8 Chapter 9 Page 9-i............................. Revision 20A Page 9-1 thru 9-2.................... Revision 2 Page 9.1-1 thru 9.1-20....... Revision 20A Page 9.2-1 thru 9.2-16....... Revision 20A Page 9.3-1 thru 9.3-18....... Revision 20A Page 9.4-1 thru 9.4-6......... Revision 20A Chapter 10 Page 10-i........................... Revision 20A Page 10-1............................... Revision 0 Page 10.1-1............................ Revision 5 Page 10.1-2............................ Revision 6 Page 10.1-3 thru 10.1-4.......... Revision 2 Page 10.1-5............................ Revision 9 Page 10.1-6 thru 10.1-23... Revision 20A Page 10.2-1 thru 10.2-2.......... Revision 9 Page 10.2-3........................ Revision 22B Page 10.3-1............................ Revision 0 Page 10.3-2............................ Revision 1 Chapter 11 Page 11-i........................... Revision 20A Page 11-1.......................... Revision 20A Page 11.1-1 thru 11.1-2.......... Revision 0 Page 11.2-1....................... Revision 20A Page 11.3-1............................ Revision 0 Page 11.3-2 thru 11.3-3..... Revision 20A Page 11.3-4............................ Revision 0 Page 11.3-5 thru 11.3-6..... Revision 20A Page 11.4-1............................ Revision 0 Page 11.5-1............................ Revision 0 Chapter 12 Page 12-i........................... Revision 20A Page 12-1............................... Revision 0 Page 12.1-1....................... Revision 20A Page 12.1-2............................ Revision 5 Page 12.1-3 thru 12.1-7..... Revision 20A Page 12.1-8............................ Revision 8 Page 12.1-9 thru 12.1-10........ Revision 5 Page 12.2-1............................ Revision 0 Page 12.2-2 thru 12.2-4..... Revision 20A
MAGNASTOR System FSAR July 2022 Docket No. 72-1031 Revision 22B List of Effective Pages (contd)
Page 7 of 7 Page 12.2-5............................ Revision 4 Page 12.2-6............................ Revision 0 Page 12.2-7 thru 12.2-21... Revision 20A Page 12.3-1 thru 12.3-2.......... Revision 0 Chapter 13 Page 13-i................................ Revision 0 Page 13-1............................... Revision 0 Page 13A-i............................. Revision 0 Page 13A-1............................. Revision 0 Page 13B-i.............................. Revision 0 Page 13B-1............................. Revision 0 Page 13C-i.............................. Revision 1 Page 13C-1............................. Revision 5 Page 13C-2 thru 13C-3..... Revision 20A Page 13C-4 thru 13C-9.......... Revision 0 Page 13C-10........................... Revision 7 Page 13C-11 thru 13C-13. Revision 20A Page 13C-14........................... Revision 1 Page 13C-15 thru 13C-16. Revision 20A Page 13C-17 thru 13C-18...... Revision 9 Page 13C-19 thru 13C-20...... Revision 5 Page 13C-21...................... Revision 20A Page 13C-22........................... Revision 1 Page 13C-23 thru 13C-24...... Revision 5 Page 13C-25 thru 13C-27...... Revision 2 Chapter 14 Page 14-i................................ Revision 0 Page 14-1 thru 14-2................ Revision 0 Page 14.1-1 thru 14.1-7.......... Revision 0 Page 14.2-1............................ Revision 0 Chapter 15 Page 15-i................................ Revision 0 Page 15-1............................... Revision 0 Page 15.1-1............................ Revision 0 Page 15.2-1 thru 15.2-4.......... Revision 0 Page 15.3-1............................ Revision 0
MAGNASTOR System FSAR July 2022 Docket No. 72-1031 Revision 22B NAC International 10.2-3 Table 10.2-1 MAGNASTOR Maintenance Program Schedule Task Frequency Visual inspection and repair or recoating of concrete cask concrete and accessible coated carbon steel surfaces Annually during storage operations Visual inspection of concrete cask identification markings Annually Load testing and/or visual and dimensional inspection of the transfer cask Annually while transfer cask is in operation, or prior to returning to service Visual inspection and repair or recoating of MTC1 transfer cask exposed carbon steel surfaces, except on sliding surfaces (does not apply to MTC2 or PMTC)
Annually while transfer cask is in operation, or prior to returning the transfer cask to service Visual inspection of MTC1 transfer cask exposed carbon steel surfaces and temporary repair of coating surfaces using site-approved materials (does not apply to MTC2, PMTC or LMTC)
Quarterly while transfer cask is in operation, or prior to returning the transfer cask to service Visual examination of welds of PMTC neutron shield and expansion tanks Annually while PMTC is in operation, or prior to returning the transfer cask to service Visual examination of welds of LMTC neutron shield and expansion tanks Annually while LMTC is in operation, or prior to returning the transfer cask to service Functional check of transfer cask sliding parts to verify adequate lubrication Each use Functional check of transfer cask inflatable seals to confirm operability Each use Visual inspection of the concrete cask lift lug bolts - if applicable Prior to each installation