ML20357A199
| ML20357A199 | |
| Person / Time | |
|---|---|
| Site: | Cook |
| Issue date: | 08/13/2018 |
| From: | Chuck Zoia Operations Branch III |
| To: | Indiana Michigan Power Co |
| Zoia C | |
| Shared Package | |
| ML17164A385 | List: |
| References | |
| Download: ML20357A199 (2) | |
Text
ES-401 Generic Knowledge and Abilities Outline (Tier 3)
Form ES-401-3 Facility: D.C. Cook Date of Exam: 06/18/2018 Category K/A #
Topic RO SRO-only IR IR
- 1. Conduct of Operations 2.1.3 Knowledge of shift or short-term relief turnover practices.
(CFR: 41.10 / 45.13) 3.7 66 2.1.4 Knowledge of individual licensed operator responsibilities related to shift staffing, such as medical requirements, no-solo operation, maintenance of active license status, 10CFR55, etc.
(CFR: 41.10 / 43.2) 3.8 94 2.1.19 Ability to use plant computers to evaluate system or component status.
(CFR: 41.10 / 45.12) 3.9 67 2.1.25 Ability to interpret reference materials, such as graphs, curves, tables, etc.
(CFR: 41.10 / 43.5 / 45.2, 45.6) 3.9 68 2.1.34 Knowledge of primary and secondary plant chemistry limits (CFR: 41.10 / 43.5 / 45.12) 3.5 95 Subtotal 3
2
- 2. Equipment Control 2.2.1 Ability to perform pre-startup procedures for the facility, including operating those controls associated with plant equipment that could affect reactivity.
(CFR: 41.5, 41.10 / 43.5, 43.6 / 45.1) 4.5 69 2.2.5 Knowledge of the process for making design or operating changes to the facility.
(CFR: 41.10 / 43.3 / 45.13) 3.2 96 2.2.35 Ability to determine Technical Specification Mode of Operation (CFR: 41.7, 41.10 / 43.2 / 45.13) 3.6 70 2.2.38 Knowledge of conditions and limitations in the facility license.
(CFR: 41.7 / 43.5 / 45.12) 4.5 97 Subtotal 2
2
- 3. Radiation Control 2.3.4 Knowledge of radiation exposure limits under normal and emergency conditions.
(CFR: 41.12 / 43.4 / 45.10) 3.2 71 2.3.5 Ability to approve release permits (CFR: 41.11, 41.12 / 43.4 / 45.9) 3.8 98 2.3.13 Knowledge of radiological safety procedures pertaining to licensed operator duties, such as response to radiation monitor alarms, containment entry requirements, fuel handling responsibilities, access to locked high-radiation areas, filters, etc.
(CFR: 41.12 / 43.4 / 45.9, 45.10) 3.4 72 Subtotal 2
1
- 4. Emergency Procedures/Plan 2.4.2 Knowledge of system set points, interlocks and automatic actions associated with EOP entry conditions (CFR: 41.7 / 43.5 / 45.13) 4.5 73 2.4.6 Knowledge of EOP mitigation strategies.
(CFR: 41.10 / 43.5 / 45.13) 3.7 74 2.4.18 Knowledge of the specific bases for EOPs (CFR: 41.10 / 43.1 / 45.13) 4.0 99 2.4.29 Knowledge of the emergency plan (CFR: 41.10 / 43.5 / 45.13) 4.4 100
ES-401 Generic Knowledge and Abilities Outline (Tier 3)
Form ES-401-3 2.4.32 Knowledge of operator response to loss of all annunciators (CFR: 41.10 / 43.5 / 45.13) 3.6 75 Subtotal 3
2 Tier 3 Point Total 10 7