ML20274A072

From kanterella
Jump to navigation Jump to search
Summary of Virtual Public Meeting/Workshop Enhancing Risk-Informed and Performance-Based Seismic Safety for Advanced Non-Light Water Reactors
ML20274A072
Person / Time
Issue date: 09/30/2020
From: Gascot-Lozada R
NRC/RES/DE/SGSEB
To: Dogan Seber
NRC/RES/DE/SGSEB
Gascot R
References
Download: ML20274A072 (8)


Text

September 30, 2020 MEMORANDUM TO: Dogan Seber, Chief Structural Geotechnical and Seismic Engineering Branch Division of Engineering Office of Nuclear Regulatory Research FROM Ramón L. Gascot Lozada, Structural Engineer/Project Manager /RA/

Structural Geotechnical and Seismic Engineering Branch Division of Engineering Office of Nuclear Regulatory Research

SUBJECT:

SUMMARY

OF VIRTUAL PUBLIC MEETING/WORKSHOP ENHANCING RISK-INFORMED AND PERFORMANCE-BASED SEISMIC SAFETY FOR ADVANCED NON-LIGHT WATER REACTORS On September 2 & 3,2020, the Office of Nuclear Regulatory Research (RES) of the U.S.

Nuclear Regulatory Commission (NRC), sponsored a Category 3 virtual Public Meeting. The purpose of this meeting was to discuss research conducted by the Office of Nuclear Regulatory Research (RES) on a proposed alternative conceptual approach to seismic safety and design for Advanced Non-light Reactors within the framework of the Licensing Modernization Project (LMP) and ASCE 43 seismic design criteria and to seek inputs and feedback from the interested stakeholders and the public.

Enclosed are the meeting agenda (Enclosure 1) and the meeting attendees list (Enclosure 2).

Non-proprietary presentation slides discussed in the meeting can be found in the Agencywide Documents Access and Management System (ADAMS), (ADAMS Accession Nos.

ML20241A151,ML20241A150, and ML20241A152).

Summary of meeting During this one-and a half-day meeting NRC staff, personnel from Southwest Research Institute (SwRI) and consultants discussed research being conducted by RES that developed a proposed alternative conceptual approach to seismic safety and physical design of nuclear power plants. The meeting opened with introductory remarks by NRC staff which included a discussion of background information and objective of the meeting. Following the staffs introductory remarks, the Southern Company representatives provided an overview on the LMP project and the treatment of external events in applying this methodology. SwRI consultants proceeded with the first part of their presentation discussing the concept of the new proposed approach, followed by a demonstration of the feasibility of this methodology through simple examples. Research and standard support to this approach was presented by the Chair of the American Society of Civil Engineers (ASCE) Nuclear Standards Committee and perspectives on using risk-informed and performance-based principles were provided by, GEH, Oklo and

NuScale representatives. To conclude the first day of the virtual public meeting/workshop, a general discussion and feedback session was held.

The second day of the virtual public meeting, started with an interactive session to discuss questions and issues related to implementation, benefits, and regulatory and licensing impacts of this approach, followed by a presentation discussing the planned phase 2 activities and scope of work. The session was concluded with a summary of the workshop and a discussion of the next steps. The public was invited to ask questions or provide comments to the NRC staff at the designated points in the agenda and all were addressed.

Enclosures:

1. Meeting Agenda
2. Meeting Attendees List

NRC/RES Virtual Public Workshop, Enhancing Risk-Informed and Performance-Based Seismic Safety for Advanced Non-Light Water Reactors September 2 & 3, 2020 Agenda Day 1 9:00 AM - 5:00 PM, (WebEx will open at 8:30 AM, registration link on page 2)

Time Topic Presenter/Leader 9:00-9:20 Announcements/Procedures NRC/Jim Xu, Louise Lund General Remarks Overview-Objectives, Processes, Challenges, and Plans Forward 9:20-9:40 Licensing Modernization Project (LMP)

LMP/Amir Afzali 9:40-10:30 Treatment of External Events in Applying Licensing Modernization Project Methodology LMP/Karl Fleming 10:30-11:30 RIPB Seismic Safety Approach (Integration of ASCE 43 Design Criteria with the LMP Framework) - Part 1: Proposed Risk-Informed and Performance-Based (RIPB) Approach SwRI/Nilesh Chokshi 11:30-12:15 Lunch (45 min) 12:15-1:25 RIPB Seismic Safety Approach (Integration of ASCE 43 Design Criteria with the LMP Framework) - Part 2: Demonstration of Feasibility through Simple Examples SwRI/Nilesh Chokshi 1:25-1:55 Research and Standards in Support of RIPB Seismic Design SUNY Buffalo/Andrew Whittaker 1:55-2:15 GEH Experience and Perspectives for Using RIPB for Seismic Design GE/Luben Todorovski 2:15-2:35 Oklo Perspectives for Using RIPB Approach to Seismic Design of Reactors Oklo/Emma Redfoot 2:35-2:55 NuScale Experience and Perspectives for Using RIPB for Seismic Design NuScale/Luke McSweeney 2:55-3:05 Break (10 min) 3:05-4:55 General Discussion and Feedback on RIPB Approach NRC-SwRI/Jim Xu 4:55-5:00 Closing NRC/Jim Xu Day 2 (9:00 AM - 12:00 PM, WebEx will open at 8:30 AM, registration link on page 2 Time Topic Presenter/Leader 9:00-9:10 Announcements/Procedures NRC 9:10-10:30 RIPB Seismic Safety Approach (Integration of ASCE 43 Design Criteria with the LMP Framework) - Part 3: Questions and Issues Related to Implementation, Benefits, and Regulatory, Technical and Other Aspects NRC-SwRI/MK Ravindra 10:30-10:40 Break 10:40-11:10 RIPB Seismic Safety Approach (Integration of ASCE 43 Design Criteria with the LMP Framework) - Part 4: Phase 2 Activities and Scope NRC-SwRI/Robert Budnitz 11:10-11:50 Discussion All Participants 11:50-12:00 Summary of Workshop, Next Steps, and Closing NRC/Jim Xu

Registration Links:

Date: 9/2/2020 Attendees URL:

https://usnrc.webex.com/usnrc/onstage/g.php?MTID=ecf12b0300dde8572f3e59fa66aa098de Call in Number: 415-527-2805 Access Code (if needed): 199 241 2805 Date: 9/3/2020 Attendees URL:

https://usnrc.webex.com/usnrc/onstage/g.php?MTID=e79320c615dc12b64a49aaaa2960f97f5 Call in Number: 415-527-5035 Access Code (if needed): 199 588 8470

Public Meeting Enhancing Risk-Informed and Performance-Based Seismic Safety for Advanced Non-Light Water Reactors September 2&3, 2020.

List of Attendees:

First Name Last Name Organization Biswajit Dasgupta SwRI Karl Fleming LMP Emma Redfoot Oklo Jim Xu NRC Jon Ake NRC Luke McSweeney NuScale Amir Afzali Southern Company Jose Pires NRC Louise Lund NRC Ramon Gascot NRC Mayasandra Ravindra SwRI Robert Budnitz SwRI Andrew Whittaker University of Buffalo John Stamatakos SwRI Luben Todorovski GE Osvaldo Pensado SwRI Alex Renner Oklo Nilesh Chokshi SwRI Steve McDuffie DOE Chandrakanth Bolisetti INL Kevin Roach NRC John Segala NRC Antonio Godoy Madhumita Sircar NRC Jason Redd NRC Ayhan Irfanoglu Purdue Hasan Charkas EPRI Frances Pimentel NEI Michael Mudlock SGH Saran Bodda NC State University Mike Tschiltz NEI Dogan Seber NRC James Johnson Kamal Manoly NRC Sujit Samaddar NRC Brian Song Kairos Hanh Phan NRC

Yueh-li Li NRC Mark Peres Kairos Andrew Prinaris NRC Tammy Morin Holtec Thomas Weaver NRC Steve Schilthelm BWX Chris Courtenay Duke Energy Camille Levine NRC George Wang NRC Farshid Shahrokhi Framatome Ata Istar NRC Carl Costantino CJC Associates Ben Kosbab SGH Andrea Maioli Westinghouse Jinsuo Nie NRC Marcos Rolon NRC Jodine Jansen Vehec Holtec Ashley Meredith NRC Bhagwat Jain NRC Chakrapani Basavaraju NRC Tim Schmitt Framatome Martin Stutzke NRC Julie Ezell NRC James Tomkins Kairos Wei Zheng BV William Reckley NRC Efe Kurt INL Payman Tehrani SC Solution Richard Paese Westinghouse Jordan Hagaman Kairos Ann Kammerer Rich Morante BNL Travis Chapman X-Energy Deb Luchsinger NuScale Yuken Wong NRC Nicole Schlichting Kairos John Richards EPRI Bret Tegeler Westinghouse Alissa Neuhausen NRC Matthew Humberstone NRC Ian Jung NRC Gurjendra Bedi NRC Dave Grabaskas ANL

Abhinav Gupta NC State University Huan Li NRC Archie Manoharan TVA Brandon Caldwell Framatome Margaret Ellenson Kairos Russell Chazell NRC Andrew Yeshnik NRC Jana Bergman Curtis Wright Kayla Gamin NRC Rasool Anooshehpoor NRC Jeff Harper X-Energy John Bolin GA Greg Hardy SGH Natalie Doulgerakis SC Solution Frederick Sock NRC Derrick Watkins Structint George Thomas NRC Julio Garcia SC Solution Robert Roche-Rivera NRC Weijun Wang NRC Ian Tseng NRC Amy Cubbage NRC Ian Tseng NRC Joe Sebrosky NRC Mehdi Reisi Fard NRC Derrick Watkins SC Solution Milton Valentin NRC Amitava Ghosh NRC Demetius Murray NRC Neil Broom USNC Carl Constantino CJC Associates

SUBJECT:

SUMMARY

OF VIRTUAL PUBLIC MEETING/WORKSHOP ENHANCING RISK-INFORMED AND PERFORMANCE-BASED SEISMIC SAFETY FOR ADVANCED NON-LIGHT WATER REACTORS Distribution:

Jose Pires, RES/DE Jim Xu, RES/DE ADAMS Accession No. ML20274A072 OFFICE RES/DE/SGSEB RES/DE/SGSEB NAME DSeber RGascot Lozada DATE 09/29/2020 09/30/2020 OFFICIAL AGENCY RECORD