ML20246H071
| ML20246H071 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 08/22/1989 |
| From: | Bates J TENNESSEE VALLEY AUTHORITY |
| To: | Wright E TENNESSEE, STATE OF |
| References | |
| NUDOCS 8909010076 | |
| Download: ML20246H071 (3) | |
Text
_ _ _ _ _ - _ - - _ _ _ _ - _ _ _ -
e TENNESSEE VALLEY AUTHORITY
~
CH ATTANOOGA, TENNESSEE 37401 11A BA Chestnut Street Towers l
August 22, 1989 Mr. Eugene Wright Moccasin Bend Pumping Station Moccasin Bend Road Chattanooga, Tennessee 37405 l
Dear Mr. Wright:
SEQUOYAH NUCLEAR PLANT (SCM - DISPOSAL OF MISCELLANEOUS WASTES SQN generates small quantities of miscellaneous wastes that are not radioactive, nor do they meet the definition of a hazardous waste. Allowance for the discharge of these wastes has not been made in the existing facility NPDES permit. TVA requests your concurrence to allow the discharge of the wastes identified in the enclosure into the Moccasin Bend Sewage Treatment Plant via the sewer line that was recently installed between SON and Soddy-Daisy. The estimated quantities and generation frequencies for these wastes arm also given in the enclosure.
We greatly appreciate your consideration in this matter. If you have questions or comments regarding this request please call Drew Miller at 751-8123 in Chattanooga.
Very truly yours, TENNESSEE VALLEY AUTHORITY L. 8&&
J L. Bates Manager, Chemistry and Environment
~
Enclosure cc (Enclosure):
Ms. S. C. Black, Assistant Director for Projects TVA Projects Division U.S. Nuclear Regulatory Commission one White Flint, North 11555 Rockville Pike Rockville, Maryland 20852 g/
1 8909010076 090822
{DR ADDCK 05000327 An Equal Opportunity Employer PNU
~!
']-
l '.' _. ;. ' )
--' ~'
[
)
s*
I
. v 2
4 p8 Mr. Eugene Wright SEQUOYAH NUCLEAR PLANT (SON) - DISPOSAL OF MISCELLANEOUS WASTES l
Mr. F. R. McCoy, Assistant Director-for Inspection Programs TVA Projects Division L
L U.S. Nuclear Regulatory Commission
-Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr. Philip L. Stewart, Manager Chattanooga Field Office Division of Water Pollution Control 2501 Milne Street Chattanooga, Tennessee 37406 Sequoyah Resident Inspector Sequoyah Nuclear Plant L
2600 Igou Ferry Road Soddy Daisy, Tennessee '37379 U.S. Nuclear Regulatory Commission [
Attention: Document Control Desk Washington, D.C.
20555 1
1 1
L l
I
- - - - - - _ _ _ - _ - _ _ _ = _ _ _
n...
.=
m
,e
.i.
+S MISCELLANEOUS WASTES FOR WHICH PERMISSION-TO DISCHARGE TO. DOMESTIC SEWER SYSTEM IS REQUESTED FREQUENCY DI WASTE USI CONCENTRATION QUANTITY GENERATIQLT l'
- Sodium Hypochlorite
'S - 15%~
100 gallon 6/yr.
- Actibrom Biocide 12.2 lbs/ gal-100 gallon 4/yr.
(Sodium bromide) dispersant Ethylene glycol Ice Condenser less than 15%
1500 gallon 2/yr.
(85% H O) 2
- Zyglo Washable 2% (98% H O) 300 gallon 1/yr.
2 penetrant
- MSDS _ attached l
I 4
l
.m____
. _ _