ML20246E851

From kanterella
Jump to navigation Jump to search
Forwards BAW-2074, Analysis of Capsule RS1-F Smud Rancho Seco Unit 1 Reactor Vessel Matl Surveillance Program. Evaluation of Specimens Indicate That Predicted Effects of Neutron Irradiation Conservative Compared to Actual Effects
ML20246E851
Person / Time
Site: Rancho Seco
Issue date: 05/01/1989
From: Croley B
SACRAMENTO MUNICIPAL UTILITY DISTRICT
To: Knighton G
Office of Nuclear Reactor Regulation
Shared Package
ML20246E853 List:
References
AGM-NTS-89-119, NUDOCS 8905120042
Download: ML20246E851 (1)


Text

_

  • 4

+

4

';SMUD SACRAMENTO MUNICIPAL UTILITY D! STRICT C 6201 S Stroat, P.O. Box 15830, Sacramento CA 95852-1830,(916) 452-3211 AN ELECTRIC SYSTEM SERVING THE HEART OF CALIFORNIA AGM/NTS89-119 May 1, 1989 U. S. N'Jclear Regulatory Commission Attn:

Document Control Desk Washington, DC 20555 Docket No. 50-312 Rancho Seco Nuclear Generating Station License No. DPR-54 EVALUATION OF REACTOR VESSEL SURVEILLANCE PROGRAM CAPSULE RSI-F Attention: George Knighton Reactor Vessel Surveillance Capsule RSI-F has been removed from the Davis-Besse reactor vessel pursuant to Rancho Seco Technical Specification Surveillance Standard 4.2.1, Reactor Vessel Surveillance Specimens. The results of the evaluation of the capsule specimens are provided in the attached report, BAW-2074, Analysis of Capsule RSl-F, dated April 1989.

The evaluation of the specimens showed that the predicted effects of neutron irradiation on the tensile and fracture toughness properties of the reactor vessel materials are conservative when compared to the actual effects. No Technical Specification changes or License Amendments are necessary since the Technical Specifications remain conservative.

Members of your staff with questiens requiring additional information or clarification may contact Mr. Ste/e Rutter at (209) 333-2935, extension 4911.

Sincerely, 4,AssistantGeneralManager Bob. Croley Nuclear Technical Services Attachment cc w/atch:

J. B. Martin, NRC, Walnut Creek A. D'Angelo, NRC, Rancho Seco h0I 8905120042 890501 i

g PDR ADOCK 05000312 j

P PDC

/

RANCHO SECo NUCLEAR GENERATING STATION D 1444o Twin Cities Roai Herald, CA 95638-9799;(209) 333-2935 J