Westingho'use Commercial Nuclear Drawer R Electric Corporation Fuel Division fen'e290 s
mm NRC-98-040 l
August 25,1998 l
U. S. Nuclear Regulatory Commission ATTN: Regional Administrator, R11 Region II-61 Forsyth Street SW, Suite 23T85 Atlanta, GA 30303
Dear Sir:
Subject:
SNM-1107/70-1151 The following report fulfills regulatory requirements as listed _in 10CFR 40.65 and 10CFR 70.59
" Effluent Monitoring Requirements." For the six-month period January 1,1998 through June 30, 1998, the following quantities of radionuclides were released to the unrestricted area by the
' Westinghouse Electric Company's Columbia, South Carolina Commercial Nuclear Fuel Division plant:
A. Gaseous 188.8 uCi Uranium (Analyzed as gross alpha)
B. Liquid Effluent-17,833.3 uCi-U-234 849.2 uCi-U-235 j
2,547.6 uCi-U-238 Gaseous effluent results were obtained from point source gross alpha analysis of stack gas effluent, and the individual radionuclides composition is inferred from the calculated average enrichment (84.0% U-234,4.0% U-235, and 12.0% U-238). A detailed summary report by stack is provided as Attachment
. A. "
Liquid effluent values were obtained by analysis of composite proportional samples prior to discharge Lto the Congaree River and basing the activity on the calculated average enrichment All liquid l
L discharges are routed through a single discharge line to Congaree River. A detailed summary liquid discharge report is provided as Attachment "B."
Sincerely, WESTINGHOUSE ELECTRIC COMPANY l.
{
c W. L. Go'dwin, Manager
^
14 Regulatory Affairs
= = = _ *
=a, -,._,.,,_.
. fMR'@"' *""*
y:Qyyy'"""""
9809020159 990825 POR; ADOCK 07001151 C-PD 7 i ine vmwvivu.w vurar R...~........Vhkyt-Whinerafthe t.998Mato/mBa/#peNahuna/Qiahh'Awam'