ML20236H724
| ML20236H724 | |
| Person / Time | |
|---|---|
| Site: | Zion File:ZionSolutions icon.png |
| Issue date: | 10/22/1987 |
| From: | Leblond P COMMONWEALTH EDISON CO. |
| To: | Davis A NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| References | |
| 3745K, NUDOCS 8711040306 | |
| Download: ML20236H724 (1) | |
Text
_ __ -
[~
Commonwealth Edison '
s
> One Fird National Plan, Ch!0ago, Illinois
(
Eddress Reply to: Post OffiCJ Box 767~
PatCRITYROUTIh'G
~
\\
Chicago, Ilknois 60690 0767
{jnt gEri v
October 22, 1987 N
i 6 B L
NU l
M (Ok i
n Mr. A. Bert Davis FILE 47 Regional Administrator I
U.S. Nuclear Regulatory Commission Region III
~/99 Roosevelt Road Glen Ellyn, IL 60137
Subject:
Zion Nuclear Power Station Units 1 and 2 Valve Quality Allegation NRC Docket Nos. 50-295 and 50-304
Reference:
July 28, 1987, letter from C.E. Morelius to Cordell-Reed
Dear Mr. Davis:
The referenced letter provided commonwealth Edison Company with an allegation regarding the quality and safe operation of products purchased from a specific valve vendor.
This situation has been carefully reviewed.
The conclusion of this review is that the check valves in question have not been utilized in the past, nor will they be used in the future at Zion Station.
Interviews were conducted with the appropriate members of the mechanical maintenance and warehouse / storeroom departments.
In addition, a historical review was conducted of previous purchase orders.
This effort demonstrated that none of the valves in question were installed in the plant, or present in storage. However, one valve was on order. A 6" dual plate check valve was listed on Purchase Order No. 310782.
i Purchase Order No. 310782 was canceled on August 17, 1987.
In addition, the corporate Quality Assurance Department has been notified to evaluate the adequacy of any future purchase orders.
If any questions arise regarding this matter, please direct them to this office.
I Very truly yours, 8711040306 871022 ADOCK0500g5 DR P. C. LeBlond l
Nuclear Licensing Administrator i
cc: Resident Inspector - Zion 4
J. A. Norris - NRR i
)
3745K
/tWMy
ocr a 8 1987 TEol
/0P lAl AAC