Letter Sequence RAI |
|---|
|
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance, Acceptance, Acceptance
|
MONTHYEARML18031A7302018-02-12012 February 2018 Honeywell International, Inc., 2018 Lr - Request for Additional Information Concerning License Renewal Application in the Areas of Integrated Safety Analysis Summary and Management Measures Project stage: RAI ML18031A7262018-02-12012 February 2018 Request for Additional Information Concerning License Renewal Application in the Areas of Integrated Safety Analysis Summary and Management Measures, Honeywell Metropolis Works (Cost Activity Code 000224/04003392/L-2017-RNW-0002) Project stage: Request ML18031A9712018-02-12012 February 2018 Honeywell International Inc., Request for Additional Information Integrated Safety Analysis Summary and Management Measures Renewal of Source Materials License No. SUB-526 Project stage: RAI ML18037B0472018-02-28028 February 2018 Telecon Summary-Honeywell LRA D-RAI Revised ISA and Mm Review 1-2018 Enclosure 2 Project stage: RAI ML18037B0322018-02-28028 February 2018 January 31, 2018 Conference Call to Clarify Draft Request for Additional Information in the Areas of Integrated Safety Analysis Summary and Management Measures, Honeywell Metropolis Works (CAC 000224/04003392/L-2017-RNW-0002) and Enclosures Project stage: Request ML18037B0422018-02-28028 February 2018 Telecon Summary-Honeywell LRA D-RAI Revised on ISA and Mm Review 1-31-2018 List of Participants Enclosure 1 Project stage: RAI ML18037B0372018-02-28028 February 2018 Telecon Summary-Honeywell LRA D-RAI Revised on ISA and Mm Review 1-31-2018 Project stage: RAI ML18113A0722018-04-12012 April 2018 Enclosure 2: Form Honeywell Meeting Summary-ISA and Mm Draft RAI Response April 12, 2018 Project stage: Draft RAI ML18113A0742018-05-15015 May 2018 Meeting Summary - Honeywell-LRA Draft RAI Response on ISA and Mm April 12, 2018 with Enclosure 1 Project stage: Draft RAI ML18187A2202018-06-29029 June 2018 Acknowledgement of Receipt of Centrus Final Status Survey Report for the American Centrifuge Lead Cascade Facility Decommissioning Project Project stage: Other ML18292A5202018-10-25025 October 2018 Acceptance Review of Louisiana Energy Services, LLC, Doing Business as Urenco USA License Amendment Request 18-01 Allowance to Feed UF6 Greater than O.72 WT % 235Urainium, But Less than 1 WT % 235Urainium Project stage: Acceptance Review ML19269B7742019-09-23023 September 2019 Us Dept. of Commerce, National Institute of Standards and Technology - NIST Decommissioning Funding Plan, September 2019 Project stage: Request ML19309E6662019-11-20020 November 2019 Acceptance of Passport Systems Inc.S Request to Terminate SNM-960 Project stage: Acceptance Review ML19317E5702019-11-20020 November 2019 Acceptance Review-2019 Decommissioning Funding Plan Submittal, SNM 362, Docket 07000398 Project stage: Acceptance Review ML20030A6792020-02-0404 February 2020 Request for Additional Information - 2019 Decommissioning Funding Plan Submittal, Special Nuclear Material License, SNM-362, Docket 07000398 (Cac/Epid 000224/07000398/L-2019-DFA-0008) Project stage: RAI ML20030A6592020-02-0404 February 2020 Request for Additional Information - 2019 Decommissioning Funding Plan Submittal, SNM 362 Project stage: Request ML20030A6812020-02-0404 February 2020 Enclosure 1 NIST 2019 DFP RAI Project stage: Other ML20066J9772020-03-0606 March 2020 Updated GEH Vallecitos Nuclear Center Decommissioning Funding Plan (DFP) Project stage: Request ML20085G2162020-04-0303 April 2020 Enclosure, Technical Evaluation Report, NIST 2019 Decommissioning Cost Estimate Project stage: Other ML20085G2152020-04-0303 April 2020 Transmittal, Approval of NIST 2019 Triennial Update to Decommissioning Funding Plan Project stage: Other ML20119A8722020-05-0808 May 2020 Acceptance of GE Vallecitos DFP with Request for Supplemental Information Project stage: Acceptance Review ML20154K6502020-06-0202 June 2020 GEH Vallecitos Decommissioning Funding Plan Supplemental Information Project stage: Request ML20174A2762020-07-0707 July 2020 Acceptance for Review of Updated Decommissioning Funding Plan for the Vallecitos Nuclear Center Project stage: Acceptance Review ML20209A0672020-10-0909 October 2020 Request for Additional Information Letter: Updated DFP for Vallecitos Nuclear Center (Vnc) Project stage: RAI ML20310A2742020-11-0505 November 2020 GE-Hitachi Nuclear Energy Americas, LLC, Response to Nrg Request for Additional Information - Vallecitos Nuclear Center Decommissioning Funding Plan Project stage: Request ML21078A0442021-03-12012 March 2021 Us Dept. of Commerce, National Institute of Standards & Technology, License Amendment Application Project stage: Other ML21126A1142021-05-20020 May 2021 Transmittal, Response to License Amendment Request Project stage: Other ML21126A1152021-05-20020 May 2021 Enclosure 1 - SEP G150 Relocation Project stage: Other ML21126A1162021-05-20020 May 2021 Enclosure 2 - SNM-362 License (Publicly Available) Project stage: Other ML21336A3182021-12-14014 December 2021 Cover Letter - Forward Second Request for Additional Information Re Updated Decommissioning Funding Plan Project stage: RAI ML22012A1482022-01-12012 January 2022 GEH Response to NRC Second Request for Additional Information - Vallecitos Nuclear Center Decommissioning Funding Plan (Enterprise Project Number 000224/07000754/L-2020-DFA-0002) Project stage: Request ML22024A3132022-01-24024 January 2022 GE-Hitachi Nuclear Energy Americas, LLC - Response to NRC Request for Vallecitos Nuclear Center CA-0017-01 Decommissioning Funding Plan Project stage: Request ML21305A8732022-03-0202 March 2022 Safety Evaluation Report on Updated Decommissioning Funding Plan for Vallecitos Nuclear Center-Cost Activity Code/Enterprise Project Identification Number 000224/07000754 Project stage: Approval ML21305A8722022-03-0202 March 2022 NRC Response: Review of GEH Updated DFP for Vallecitos Nuclear Center Project stage: Approval ML21305A8712022-03-0202 March 2022 Review of GEH Updated DFP for Vallecitos Nuclear Center Project stage: Request ML22084A5782022-03-23023 March 2022 GNF-A/GEH Financial Assurance of Decommissioning Funds - Surety Bond Riders Cover Letter and Affidavit Project stage: Request ML22089A0872022-03-30030 March 2022 Updated GEH Vallecitos Nuclear Center (Vnc) Decommissioning Funding Plan (DFP) Project stage: Request ML22108A2982022-04-20020 April 2022 NRC Response on Amendment 2 to SNM-960 for GE Vallecitos Nuclear Center Project stage: Request ML22108A2992022-04-20020 April 2022 General Electric-Hitachi 2020 Triennial Update to Decommissioning Funding Plan (Enterprise Project Identifier L-2020-DFA-0002 Project stage: Other ML22108A3012022-04-20020 April 2022 GE-Hitachi Nuclear Energy Americas, Llc., SNM-960 Amendment 2 (Public Version) Project stage: Other 2020-04-03
[Table View] |
Text
OFFICIAL USE ONLY-SECURITY-RELATED INFORMATION OFFICIAL USE ONLY-SECURITY-RELATED INFORMATION Mr. Scott P. Murray Manager, Facility Licensing GE Hitachi Nuclear Energy 3901 Castle Hayne Road P.O. Box 780 Wilmington, NC 28402
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION REGARDING UPDATED DECOMMISSIONING FUNDING PLAN FOR GENERAL ELECTRIC-HITACHI VALLECITOS NUCLEAR CENTER - COST ACTIVITY CODE ENTERPRISE PROJECT IDENTIFICATION NUMBER 000224/07000754/L-2020-DFA-0002
Dear Mr. Murray:
This is in regard to General Electric-Hitachis (GEH) submittal dated March 6, 2020 (Agencywide Documents Access and Management System (ADAMS) Number ML20066J977),
and supplemental information dated June 2, 2020 (ADAMS Accession No. ML20154K650) providing the U.S. Nuclear Regulatory Commission (NRC) an updated decommissioning funding plan for the Vallecitos Nuclear Center.
Our review of GEHs submittal has identified additional information that is needed before final action can be taken. The additional information specified in the enclosure should be provided to the NRC within 45 days from the date of this letter. Please reference Enterprise Project Identification Number L-2020-DFA-0002 and Docket Number 70-0754 in your response.
In accordance with Title 10 of the Code of Federal Regulations, Section 2.390, Public inspections, exemptions, requests for withholding, of the NRCs Agency Rules of Practice and Procedure, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of the NRCs ADAMS. ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
October 9, 2020 The document transmitted by this letter contains Security-Related Information. When separated from the enclosure this letter is decontrolled.
OFFICIAL USE ONLY-SECURITY-RELATED INFORMATION OFFICIAL USE ONLY-SECURITY-RELATED INFORMATION S. Murray 2
Siurano-Perez If you have any questions regarding this communication, please contact me at (301) 415-7827, or via e-mail at Osiris.Siurano-Perez@nrc.gov.
Sincerely, Osiris Digitally signed by Osiris Siurano-Perez Date: 2020.10.09 06:47:35 -04'00' Osiris Siurano-Pérez, Project Manager Fuel Facility Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 70-0754 License No.: SNM-960
Enclosures:
Request for Additional Information
ML20209A066 (Pkg)
ML20209A067 (Ltr) ML20209A068 (Encl)
- via email OFFICE DFM/FFLB/PM*
DFM/FFLB
/LA*
REFS/FAB/BC*
DFM/FFLB/BC (A)*
DFM/FFLB/PM*
NAME OSiurano ELee FMiller DMarcano OSiurano DATE 7/2/2020, 9/30/2020 7/28/2020 7/28/2020 10/08/2020 10/09/2020