Text
_
.
. - _ _ _ _ . _ . _ _ _ . _ . . _ _ . _ _ . _ . _ . _ _ _ _ _ _ . _ _ _ _ _ _
_
Nation:t A: ton:utics cnd Sp:ca
February 13, 1998
,
Administration
Lewis R:sxrch Centsr
,
Mr. Robert P. Korar, Chief,
i
'
Plum Brook Management Office
21000 Brookpark Road
Cleveland, Ohio 44135
,
Dear Mr. Korar:
!
SUBJECT:
ROUTINE SAFETY INSPECTION REPORT NO. 50 030/98201 AND
50 185/98201
This refers to the routine safety inspection conducted on January 28 through 29,1998, at
the Pium Brook Reactor Facility (PBRF). The purpose of the inspection was to determine
,
whether activities authorized by the license were conducted safely and in accordance with
NRC requirements. At the conclusion of the inspection, the findings were discussed with
you and members of your staff.
,
Areas examined during the inspection are identified in the enclosed report. Within these
areas, the inspection consisted of a selective examination of procedures and representative
'
i
"
records, interviews with personnel, observation of activities in progress, and a
whik through of the facility.
No violations of NRC requirements were identified during the course of this inspection.
In accordance with 10 CFR Part 2.790 of the Commission's regulations, a copy of this
letter and the enclosed inspection report will be placed in the NRC Public Document Room.
-
Sincerely,
ORIGINAL SIGNED BY: Ant.hony Markley for
Seymour H. Weiss, Director,
i
Non-Power Reactors and Decommissioning
$22gD
$0$30
.
Project Directorate
1
0
Division or Reactor Program Management
i
Office of Nuclear Reactor Regulation
Docket Nos.50-030,50 185
i
License Nos. TR 3, R 93
hh
1
Enclosure: Inspection Reports
Nos. 50 30/98201(DRPM), and
50185/98201(DRPM)
mm
p{. m r- - r ~ ~ M N
t b LO La
cc: See next page
Distribution: w/ enclosure
.
ie'
~
l
*l,lllll ll lll
'
E MAIL
HARD COPY
TBurdick
TDragoun
Pisaac
Docket File 50-030 & 158:
JRoe
,
PDoyle
TMichaels
PUBLIC
SWeiss
CBassett
WEresian
EHylton
PDND r/f
AAdams
SHolmes
MMendonca
OC/LFDCB
g
Hn
}
PDND:PM
POND:RI
PCQOfiA
PDND:D
MMendonca
TBurdick
/
EflyRon
SWeiss
2/3/98_
2/2/98
.
2fl/98
2/6/98 N
'
OFFICIAL RECORD COPY
DOCUMENT NAME: G:\\SECY\\MENDONCA\\ NASA 98.201
_
.
. -
_
-~
. - - .
.
.._
.
.
.
.
.
p*Uoog
g*-
4
UNITED STATES
g
,j
NUCLEAR REGULATORY COMMISSION
2
WASHINGTON, o.C. 30MH001
'4,.....
February 13, 1998
National Aeronautics and Space
Administration
Lewis Research Center
Mr. Robert P. Kozar, Chief,
Plum Brook Management Office
21000 Brookpark Road
Cleveland, Ohio 44135
Dear Mr. Kozar:
SUBJECT:
ROUTINE SAFETY INSPECTION REPORT NO. 50 030/98201 AND
50 185/98201
This refers to the routine safety inspection conducted on January 28 through 29,1998, at
the Plum Brook Reactor Facility (PBRF). The purpose of the inspection was to determine
whether activities authorized by the license were conducted safely and in accordance with
NRC requirements. At the conclusion of the inspection, the findings were discussed with
you and members of your staff.
Areas examined during the inspection are identified in the enclosed report. Within these
areas, the inspection consisted of a selective examination of procedures and representative
records, interviews with personnel, observation of activities in progress, and a
f
walk through of the f acility.
No violations of NRC requirements were identified during the course of this inspection.
In accordance with 10 CFR Part 2.790 of the Commission's regulations, a copy of this
letter and the enclosed inspection report will be placed in the NRC Public Document Room.
Sincerely,
,
,sc F k
Seymour'fi. Weiss, btiector,
Non Power Reactors and Decommissioning
Project Directorate
Division or Reactor Program Management
Office of N6 clear Reactor Regulation
Docket Nos.50-030,50 185
License Nos. TR 3, R-93
Enclosure: Inspection Reports
Nos. 50 30/98201(DRPM), and
50185/98201(DRPM)
cc: See next page
.
- _ _ . _ _ _
_ ..~. _ . _ _ __... _ _
m_.,_____._
_____
,
,
i
.
National Aeronautics and
Docket Nos. 50 30/185
Space Administration
,
cc:
i
i
Ohio Department of Health
!
ATTN: Radiological Health Pro 0 ram
)
Director
i
P. O. Box 118
l
Columbus, Ohio 43216
i
Ohio Environmental Protection Agency
Division of Planning
Environmental Assessment Section
3-
P. O. Box 1049
j
Columbus, Ohio 43210
l
Ohio Department of Industrial Relations
<
'
AT1N: Chief, Boiler and Pressure
i
Vessel Division
P. O. Box 825
j
Columbus, Ohio 43216
Ms. Celeste Lipp
Bureau of Radiation Protection
Ohio Department of Health
i
P. O. Box 118
i
Columbus, Ohio 43216
Mr. Hank Pfanner
'
'
)
i-
Plumbrook Station
- -
6100 Columbus Ave.
l
Sandusky, Ohio 44870
,
9