ML20199J426

From kanterella
Jump to navigation Jump to search
Discusses Insp of Adesa Auctions Indianapolis on 971022 & Forwards NOV Involving Unauthorized Transfer of Approx 15 Mci of Po-210
ML20199J426
Person / Time
Issue date: 11/21/1997
From: Pederson C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Best R
AFFILIATION NOT ASSIGNED
Shared Package
ML20199J431 List:
References
REF-QA-99990003-971121 99990003, NUDOCS 9711280142
Download: ML20199J426 (1)


Text

MD c

November 21, 1997 Ron Best Body Shop Manager Adesa Auctions Indianapolis 2950 E. Main Street Plainfield,IN 46168

SUBJECT:

NOTICE OF VIOLATION

Dear Mr. Best:

This refers to your letter dated October 22,1997, notifying NRC Region ll1 office of the loss of a polonium-210 source used in a static elimination device. The devL;e, Model P-2051 was manufactured by NRD, Inc., and contained a nominal 15 millicuries (555 MBq) of polonium-210 as of July 1994. On or about September 1997, the source was discovered missing. Interviews with employees and search efforts to recover the missing source proved unsuccessful. Your investigation concluded that the device was inadvertently disposed of as ordinary waste or stolen from the company by a former employee.

After reviewing this incident, a violation of NRC requirements was identified. The violation involves the unauthorized transfer of approximately 15 millicuries of polonium-210, and is described in the enclosed Notice of Violation. A written response is required.

Although the amount of polonium-210 discarded /ctolen was small, tho violation demonstrates the importance of maintaining adequate control of all radioactive material to ensure that improper handling or disposal does not occur. We caution you that any similar violation in the future will carry increased significance and may result in additional enforcement action, including imposition of monetary penalties, in accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter, the enclosure, and your response to this letter will be placed in the NRC Public Document Room (PDR). To the extent possible, your response should not include any personal privacy, proprietary, or safeguards information so that it can be placed in the PDR without redaction.

We will giadly discuss any questions you have conceming this matter.

Sincerely, Original Signed by 9711290142 971121 i

.} j REQ 3 OA999 ENV***R Cynthia D. Pederson, Director q

99990003 PD Division of Nuclear Materials Safety General License (10 CFR 31.5)

Enclosure:

Notice of Violation bec w/er;l:

B. Clayton, EICS PUBLIC IE07 b

I hi$fb

$$ $$!,hllk{kll\\kl}l DOCUMENT NAME: G:\\lNSPRPTS\\MTLS\\070\\99990303.ADE To recatw a copy of this document. Ind6cate in the box: "Cae Copy vetmut attachmenvenobaure "E" = Copy wdh attachment /encbsure "N" =

Nn epy n

IOFFICE DNMS/ Rill l( DNMS/Rlli lE DNMS/R)nl// l l

m NAME-DAPiskura:bttb

. JRMadMdA CPederdeff DATE 11/ 2 0 /97 /

11/ 90M7 11/j97 -

OFFICIAL RECORD COPY hum