ML20174A554
| ML20174A554 | |
| Person / Time | |
|---|---|
| Site: | 07201031 |
| Issue date: | 07/28/2020 |
| From: | Office of Nuclear Material Safety and Safeguards |
| To: | NAC International |
| BWhite NMSS/DFM/STL 415.6577 | |
| Shared Package | |
| ML20174A550 | List: |
| References | |
| Download: ML20174A554 (144) | |
Text
Certificate of Compliance No. 1031 Amendment No. 9 APPENDIX B PROPOSED APPROVED CONTENTS FOR THE MAGNASTOR SYSTEM AMENDMENT 9
Certificate of Compliance No. 1031 B-1 Amendment No. 9 Appendix B Table of Contents 1.0 FUEL SPECIFICATIONS AND LOADING CONDITIONS......................................................... B1-1 2.0 FUEL TO BE STORED IN THE MAGNASTOR SYSTEM......................................................... B2-1 List of Figures Figure B2-1 Schematic of 37 - Fuel Storage Location Map......... B2-11 Figure B2-2
[DELETED]................................................................................................................. B2-12 Figure B2-3
[DELETED].... B2-12 Figure B2-4 Schematic of 87-Assembly BWR Basket....................B2-18 Figure B2-5 Schematic of 82-Assembly BWR Basket.................................................................... B2-19 Figure B2-6 BWR Partial Length Fuel Rod Location Sketches..................................................... B2-20 List of Tables Table B2-1 TSC with PWR Fuel Limits............................................................................................ B2-2 Table B2-2 PWR Fuel Loading Patterns........................................................................................ B2-5 Table B2-3 Bounding PWR Fuel Assembly Physical Characteristics............................................ B2-6 Table B2-4 Bounding PWR Fuel Assembly Loading Criteria - Enrichment/Soluble Boron Limits...................................................................................................................B2-7 Table B2-5 Additional SNF Assembly Cool Time Required to Load NONFUEL HARDWARE................................................................................................................. B2-8 Table B2-6 Allowed BPAA/NSA Burnup and Cool Time Combinations......................................... B2-9 Table B2-7 Allowed GTPD/NSA Burnup and Cool Time Combinations......................................... B2-9 Table B2-8 Minimum Cool Time Summary Table......................................................................... B2-10 Table B2-9 TSC with BWR Fuel Limits......................................................................................... B2-13 Table B2-10 BWR SNF Assembly Characteristics......................................................................... B2-15 Table B2-11 BWR SNF Assembly Loading Criteria....................................................................... B2-16 Table B2-12 BWR SNF Assembly Loading Criteria - Enrichment Limits for 87-Assembly and 82-Assembly Configurations......................................................... B2-17 Table B2-13 PWR Loading Table - Low SNF Assembly Average Burnup Enrichment Limits.......................................................................................................................... B2-21 Table B2-14 BWR Loading Table - Low SNF Assembly Average Burnup Enrichment Limits........................................................................................................................... B2-21 Table B2-15 Loading Table for PWR Fuel - 959 W/Assembly...................................................... B2-22 Table B2-16 Loading Table for PWR Fuel - 911 W/Assembly...................................................... B2-27 Table B2-17 Loading Table for PWR Fuel - 1,200 W/Assembly................................................... B2-35 Table B2-18 Loading Table for PWR Fuel - 1,140 W/Assembly................................................... B2-40 Table B2-19 Loading Table for PWR Fuel - 922 W/Assembly...................................................... B2-48 Table B2-20 Loading Table for PWR Fuel - 876 W/Assembly...................................................... B2-53 Table B2-21 Loading Table for PWR Fuel - 800 W/Assembly...................................................... B2-61 Table B2-22 Loading Table for PWR Fuel - 760 W/Assembly...................................................... B2-66 Table B2-23 Loading Table for BWR Fuel - 379 W/Assembly...................................................... B2-74 Table B2-24 Loading Table for BWR Fuel - 360 W/Assembly............................................................ B2-79 Table B2-25 Loading Table for PWR Fuel - 959 W/Assembly - WE 14x14 Fuel............................ B2-87 Table B2-26 Loading Table for PWR Fuel - 513 W/Assembly - WE 14x14 Fuel............................ B2-90 Table B2-27 Loading Table for PWR Fuel - 1300 W/Assembly - WE 14x14 Fuel.......................... B2-93 Table B2-28 Loading Table for PWR Fuel - 1800 W/Assembly - WE 14x14 Fuel.......................... B2-96 Table B2-29 Loading Table for PWR Fuel - 830 W/Assembly - WE 14x14 Fuel............................ B2-99 Table B2-30 Loading Table for PWR Fuel - 487 W/Assembly - WE 14x14 Fuel.......................... B2-102 Table B2-31 Loading Table for PWR Fuel - 1235 W/Assembly - WE 14x14 Fuel........................ B2-105 Table B2-32 Loading Table for PWR Fuel - 1710 W/Assembly - WE 14x14 Fuel........................ B2-108 Table B2-33 Loading Table for PWR Fuel - 788 W/Assembly - WE 14x14 Fuel.......................... B2-111
Certificate of Compliance No. 1031 B-2 Amendment No. 9 Table B2-34 Loading Table for PWR Fuel - 513 W/Assembly - CE 16x16 Fuel........................... B2-114 Table B2-35 Loading Table for PWR Fuel - 1300 W/Assembly - CE 16x16 Fuel......................... B2-117 Table B2-36 Loading Table for PWR Fuel - 1800 W/Assembly - CE 16x16 Fuel......................... B2-120 Table B2-37 Loading Table for PWR Fuel - 830 W/Assembly - CE 16x16 Fuel........................... B2-123 Table B2-38 Loading Table for PWR Fuel - 487 W/Assembly - CE 16x16 Fuel........................... B2-126 Table B2-39 Loading Table for PWR Fuel - 1235 W/Assembly - CE 16x16 Fuel......................... B2-129 Table B2-40 Loading Table for PWR Fuel - 1710 W/Assembly - CE 16x16 Fuel......................... B2-132 Table B2-41 Loading Table for PWR Fuel - 788 W/Assembly - CE 16x16 Fuel........................... B2-135 Table B2-42 Low SNF Assembly Average Burnup Enrichment Limits for CE 16x16 Fuel Loaded via the PMTC............................................................................................. B2-138 Table B2-43 Loading Table for CE 16x16 Fuel Loaded via the PMTC......................................... B2-138
Appendix B Approved Contents Certificate of Compliance No. 1031 B1-1 Amendment No. 9 1.0 FUEL SPECIFICATIONS AND LOADING CONDITIONS The MAGNASTOR SYSTEM is designed to safely store up to 37 undamaged PWR fuel assemblies in the 37 PWR Basket Assembly or up to 87 undamaged BWR fuel assemblies in the 87 BWR Basket Assembly. The system is also designed to store up to 4 damaged fuel cans (DFCs) in the DF Basket Assembly.
The DF Basket Assembly has a capacity of up to 37 undamaged PWR fuel assemblies including 4 DFC locations. DFCs may be placed in up to 4 of the DFC locations. Each DFC may contain an undamaged PWR fuel assembly, a damaged PWR fuel assembly, or PWR FUEL DEBRIS equivalent to one PWR fuel assembly. FUEL DEBRIS is included in the definition of DAMAGED FUEL (Appendix A, Section 1.1). PWR UNDAMAGED FUEL assemblies may be placed directly in the DFC locations of a DF Basket Assembly without the use of a DFC.
The system requires few operating controls. The principal controls and limits for MAGNASTOR are satisfied by the selection of fuel for storage that meets the Approved Contents presented in this section and in the tables for MAGNASTOR design basis spent fuels.
If any Fuel Specification or Loading Condition of this section is violated, the following actions shall be completed:
The affected fuel assemblies shall be placed in a safe condition.
Within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, notify the NRC Operations Center.
Within 60 days, submit a special report that describes the cause of the violation and actions taken to restore or demonstrate compliance and prevent reoccurrence.
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-1 Amendment No. 9 2.0 FUEL TO BE STORED IN THE MAGNASTOR SYSTEM UNDAMAGED PWR FUEL ASSEMBLIES, DAMAGED PWR FUEL ASSEMBLIES, PWR FUEL DEBRIS (DAMAGED FUEL), UNDAMAGED BWR FUEL ASSEMBLIES and NONFUEL HARDWARE meeting the limits specified in this section may be stored in the MAGNASTOR SYSTEM.
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-2 Amendment No. 9 Table B2-1 TSC with PWR Fuel Limits I. TSC with PWR Basket Assembly and PWR DF Basket Assembly A. Allowable Contents
- 1. Uranium PWR UNDAMAGED SNF ASSEMBLIES and DAMAGED FUEL (PWR DAMAGED SNF ASSEMBLIES or PWR FUEL DEBRIS) that meet the following specifications:
- a. Cladding Type:
Zirconium-based alloy.
- b. Physical Characteristics The physical characteristics of the different PWR SNF ASSEMBLIES are defined in Table B2-3.
- c. Maximum Enrichment The fuel type specific maximum enrichments as a function of neutron absorber sheet areal density at various minimum soluble boron levels are defined in Table B2-4. For variable enrichment SNF assemblies, maximum SNF enrichments represent peak rod/pellet enrichments.
- d. Decay Heat per SNF Assembly Load pattern dependent allowed heat loads for each fuel storage location illustrated in Figure B2-1 are shown in Table B2-2. Links to correlate allowed heat load to load tables are summarized in Table B2-8. Load tables contain minimum SNF cool time as a function of maximum SNF assembly average burnup and minimum assembly average enrichment.
- e. Nominal Fresh SNF Assy:
Length (in) 178.3
- f. Nominal Fresh SNF Assembly Width (in.):
8.54
- g. Weight Per Storage location (lbs.)
1,765, including SNF Assembly, NONFUEL HARDWARE, DFC and fuel spacer
- h. DF Basket -Total Canister Contents Weight (lbs.)
61,184, including SNF Assemblies, NONFUEL HARDWARE, DFCs and fuel spacers
- i. Total Canister Weight including Contents (lbs.)
104,500 (nominal TSC weight plus maximum contents)
- j. Total Canister Contents Weight non-DF Basket (lbs.)
62,160, including SNF Assemblies, NONFUEL HARDWARE and fuel spacers (continued)
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-3 Amendment No. 9 Table B2-1 TSC with PWR Fuel Limits (continued)
B. Quantity per TSC: Up to a total of 37 PWR UNDAMAGED SNF ASSEMBLIES including up to four (4) DFCs containing PWR UNDAMAGED SNF ASSEMBLIES, PWR DAMAGED SNF ASSEMBLIES, and/or PWR FUEL DEBRIS. DFCs may only be loaded in the DFC basket and are limited to locations No. 4, 8, 30 and 34, as shown on Figure B2-1.
C. The contents of a DFC must be less than, or equivalent to, one PWR UNDAMAGED SNF ASSEMBLY. PWR SNF ASSEMBLIES loaded in a DFC shall not contain NONFUEL HARDWARE with the exception of instrument tube tie components, guide tube anchors or steel inserts, and similar devices.
D. SNF assembly lattices not containing the nominal number of fuel rods specified in Table B2-3 must contain solid filler rods that displace a volume equal to, or greater than, that of the fuel rod that the filler rod replaces. An unenriched rod may be used as a replacement rod to return a fuel assembly to an undamaged condition. SNF assemblies may have stainless steel rods inserted to displace guide tube dashpot water.
E. PWR UNDAMAGED SNF ASSEMBLIES not loaded in a DFC may contain NONFUEL HARDWARE. SNF assembly lattices not containing the nominal number of fuel rods specified in Table B2-3 must contain solid filler rods that displace a volume equal to, or greater than, that of the fuel rod that the filler rod replaces. SNF assemblies may have stainless steel rods inserted to displace guide tube dashpot water. NONFUEL HARDWARE cool times shall be in accordance with Tables B2-5, B2-6, and B2-7. Alternatively, the 60Co curie limits in Tables B2-6 and B2-7 may be used to establish site-specific NONFUEL HARDWARE constraints. Alternatively, the 60Co curie limits in Tables B2-6 and B2-7 may be used to establish site-specific NONFUEL HARDWARE constraints.
F. Spacers may be used in a TSC to axially position PWR UNDAMAGED SNF ASSEMBLIES, and DFCs to facilitate handling and operation.
G. Unenriched fuel assemblies and unirradiated (i.e., not inserted in-core) fuel assemblies are not authorized for loading. Unenriched end blankets are permitted, provided that the nominal length of the end blanket is not greater than six (6) inches. Low enriched and annular fuel pellet end blankets are permitted without a restriction on length.
H. RCCs are limited to fuel cell location, minimum cool time, and maximum exposure based on load pattern and fuel type:
Minimum Cool Time (years)
Maximum Exposure (GWd/MTU)
Fuel Type Load Pattern Allowed Fuel Storage Locations (per Figure B2-1) 1.75 75 BW15x15 E, F, G, H A, B, C 10 180 All All A
2.5 WE14x14 A, C A
5.0 CE16x16 A, C A
14 270 All All A
3.75 315 BW15x15 E, F, G, H A, B, C 20 360 All All A
(continued)
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-4 Amendment No. 9 Table B2-1 TSC with PWR Fuel Limits (continued)
I.
One Neutron Source, or Neutron Source Assembly (NSA) is permitted to be loaded in a TSC in fuel storage locations No. 11, 12, 13, 18, 19, 20, 25, 26 or 27 (Figure B2-1). Neutron source assemblies may contain source rods attached to hardware similar in configuration to guide tube plug devices (thimble plugs) and burnable absorbers, in addition to containing burnable poison rodlets and/or thimble plug rodlets. For NSAs containing absorber rodlets, the BPAA cool time and burnup/exposure or hardware 60Co curie limit listed in Table B2-6 are applied to the neutron sources. NSAs having only thimble plug rodlets require the thimble plug restriction in Table B2-7 to be applied. Combination NSAs, containing both thimble plug and burnable absorber rodlets must apply the more limiting of the two minimum cool time/curie limit.
J. Fuel assemblies may contain any number of unirradiated (i.e., not inserted in-core) nonfuel solid filler fuel replacement rods. Steel rods are limited to a 32.5 GWd/MTU maximum burnup/exposure. In-core activated stainless steel rods are limited to minimum cool time, quantity and fuel storage locations:
Fuel Storage Location (per Figure B2-1)
Number of Assemblies per Cask Maximum number of Rods per Assembly and Minimum Cool Time C, B2 or B3 1
Maximum of 5 rods at minimum 9-year cool time or maximum 10 rods at 18-year minimum cool time A or B1 4
Maximum of 10 rods at minimum 9-year cool time K. Fuel assemblies may contain an HFRA at a maximum burnup/exposure of 4.0 GWd/MTU and a minimum cool time of 16 years.
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-5 Amendment No. 9 Table B2-2 PWR Fuel Loading Patterns Loading Pattern and Max Heat Load per Storage Location (W)(1)
Storage Location A
B C
D E
F G
H A1 959 922 513 811 425 350 300 300 A2 800 800 800 800 A3 425 350 300 800 B1 1,200 1,800 1,300 1000 2500 2000 B2 1,300 1,100 900 600 800 B3 250 250 700 700 C1 800 830 950 1800 800 800 C2 900 900 650 750 C3 1000 900 2000 2050 C4 3,400 2800 1500 1500 C5 150 950 950 Max Heat Load per Cask 35,500 35,500 35,500 30,000 35,500 35,500 35,500 35,500 Pattern Use Limitations None None CE16x16 or WE14x14 CE16x16 when using the PMTC BW15x15 in MTC2 and CC6 BW15x15 in MTC2 and CC6 BW15x15 in MTC2 and CC6 BW15x15 in MTC2 and CC6 Notes:
Locations per Figure B2-1.
Listed heat load is combined total of fuel assembly and nonfuel hardware, if applicable.
(1) Loading patterns are referred to in the FSAR as follows:
A - Uniform Loading Pattern B - Preferential Three-Zone Loading Pattern C - Preferential Four-Zone Loading Pattern (with Reduced Cool Times)
D - Uniform PMTC Loading Pattern E - Loading Pattern - X F - Loading Pattern - Y G - Loading Pattern - Z H - Loading Pattern - Z-Prime
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-6 Amendment No. 9 Table B2-3 Bounding PWR Fuel Physical Characteristics Assembly Type Assembly Subtype No. of Fuel Rods No. of Guide Tubes1 Geometry 2 Max Pitch (inch)
Min Clad OD (inch)
Min Clad Thick.
(inch)
Max Pellet OD (inch)
Max Active Length (inch)
Max Load (MTU)
BW15x15 BW15H1 208 17 0.568 0.43 0.0265 0.3686 144.0 0.4858 BW15H2 208 17 0.568 0.43 0.025 0.3735 144.0 0.4988 BW15H3 208 17 0.568 0.428 0.023 0.3742 144.0 0.5006 BW15H4 208 17 0.568 0.414 0.022 0.3622 144.0 0.4690 BW15H5 208 17 0.568 0.422 0.0243 0.3659 144.0 0.4787 BW17x17 BW17H1 264 25 0.502 0.377 0.022 0.3252 144.0 0.4799 CE14x14 CE14H1 176 5
0.58 0.44 0.026 0.3805 137.0 0.4167 CE16x16 CE16H1 236 5
0.5063 0.382 0.025 0.3255 150.0 0.4463 WE14x14 WE14H1 179 17 0.556 0.40 0.0162 0.3674 145.2 0.4188 WE15x15 WE15H1 204 21 0.563 0.422 0.0242 0.3669 144.0 0.4720 WE15H2 204 21 0.563 0.417 0.0265 0.357 144.0 0.4469 WE17x17 WE17H1 264 25 0.496 0.372 0.0205 0.3232 144.0 0.4740 WE17H2 264 25 0.496 0.36 0.0225 0.3088 144.0 0.4327 1 Combined number of guide and instrument tubes.
2 Assembly characteristics represent cold, unirradiated, nominal configurations.
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-7 Amendment No. 9 Table B2-4 Bounding PWR Fuel Assembly Loading Criteria -
Enrichment/Soluble Boron Limits TSC Containing only Undamaged Fuel - Max. Initial Enrichment (wt % 235U)
Absorbe8Fr1 0.036 10B g/cm2 Absorber1 0.030 10B g/cm2 Absorber1 0.027 10B g/cm2 Soluble Boron 1500 (ppm) 1750 (ppm) 2000 (ppm) 2250 (ppm) 2500 (ppm) 2650 (ppm) 1500 (ppm) 1750 (ppm) 2000 (ppm) 2250 (ppm) 2500 (ppm) 1500 (ppm) 1750 (ppm) 2000 (ppm) 2250 (ppm) 2500 (ppm)
BW15H1 3.7%
4.1%
4.4% 4.7% 5.0%
3.6%
4.0%
4.2% 4.5% 4.8%
3.6% 3.9% 4.2% 4.5%
4.8%
BW15H2 3.7%
4.0%
4.3% 4.6% 4.9% 5.0%
3.6%
3.9%
4.2% 4.5% 4.8%
3.6% 3.8% 4.1% 4.4%
4.7%
BW15H3 3.7%
4.0%
4.3% 4.6% 4.9%
3.6%
3.9%
4.2% 4.4% 4.7%
3.5% 3.8% 4.1% 4.4%
4.7%
BW15H4 3.8%
4.2%
4.5% 4.8% 5.0%
3.7%
4.1%
4.4% 4.7% 5.0%
3.7% 4.0% 4.3% 4.6%
5.0%
BW15H5 5.0%
BW17H1 3.7%
4.0%
4.3% 4.6% 4.9%
3.6%
3.9%
4.2% 4.5% 4.8%
3.6% 3.9% 4.1% 4.5%
4.7%
CE14H1 4.5%
4.8%
5.0% 5.0% 5.0%
4.3%
4.7%
5.0% 5.0% 5.0%
4.3% 4.6% 5.0% 5.0%
5.0%
CE16H1 4.4%
4.8%
5.0% 5.0% 5.0%
4.3%
4.6%
5.0% 5.0% 5.0%
4.2% 4.6% 4.9% 5.0%
5.0%
WE14H1 4.7%
5.0%
5.0% 5.0% 5.0%
4.6%
5.0%
5.0% 5.0% 5.0%
4.5% 5.0% 5.0% 5.0%
5.0%
WE15H1 3.8%
4.2%
4.5% 4.8% 5.0%
3.7%
4.1%
4.4% 4.7% 5.0%
3.7% 4.0% 4.3% 4.6%
4.9%
WE15H2 4.0%
4.4%
4.7% 5.0% 5.0%
3.9%
4.2%
4.6% 4.9% 5.0%
3.8% 4.2% 4.5% 4.8%
5.0%
WE17H1 3.7%
4.1%
4.4% 4.7% 5.0%
3.7%
4.0%
4.3% 4.6% 4.9%
3.6% 3.9% 4.2% 4.5%
4.9%
WE17H2 4.0%
4.3%
4.7% 5.0% 5.0%
3.9%
4.3%
4.6% 4.9% 5.0%
3.8% 4.2% 4.5% 4.9%
5.0%
TSC Containing Damaged Fuel - Max. Initial Enrichment (wt % 235U)
BW15H1 3.7% 4.0%
4.3% 4.6% 4.9%
3.6% 3.9%
4.2%
4.5%
4.7%
3.6% 3.8% 4.1% 4.4%
4.7%
BW15H2 3.6% 3.9%
4.2% 4.5% 4.8% 5.0%
3.6% 3.8%
4.1%
4.4%
4.7%
3.5% 3.8% 4.1% 4.3%
4.6%
BW15H3 3.6% 3.9%
4.2% 4.5% 4.8%
3.5% 3.8%
4.1%
4.4%
4.6%
3.5% 3.8% 4.0% 4.3%
4.6%
BW15H4 3.8% 4.1%
4.4% 4.7% 5.0%
3.7% 4.0%
4.3%
4.6%
4.9%
3.6% 3.9% 4.2% 4.5%
4.8%
BW15H5 4.9%
BW17H1 3.6% 3.9%
4.2% 4.5% 4.8%
3.6% 3.9%
4.1%
4.4%
4.7%
3.5% 3.8% 4.1% 4.4%
4.6%
CE14H1 4.4% 4.8%
5.0% 5.0% 5.0%
4.3% 4.7%
5.0%
5.0%
5.0%
4.3% 4.6% 4.9% 5.0%
5.0%
CE16H1 4.4% 4.7%
5.0% 5.0% 5.0%
4.2% 4.6%
5.0%
5.0%
5.0%
4.2% 4.5% 4.9% 5.0%
5.0%
WE14H1 4.6% 5.0%
5.0% 5.0% 5.0%
4.5% 5.0%
5.0%
5.0%
5.0%
4.5% 4.9% 5.0% 5.0%
5.0%
WE15H1 3.8% 4.1%
4.4% 4.7% 5.0%
3.7% 4.0%
4.3%
4.6%
4.9%
3.6% 4.0% 4.3% 4.6%
4.8%
WE15H2 3.9% 4.3%
4.6% 4.9% 5.0%
3.8% 4.2%
4.5%
4.8%
5.0%
3.8% 4.1% 4.4% 4.7%
5.0%
WE17H1 3.7% 4.0%
4.3% 4.6% 4.9%
3.6% 3.9%
4.2%
4.5%
4.8%
3.6% 3.9% 4.2% 4.5%
4.8%
WE17H2 3.9% 4.3%
4.6% 5.0% 5.0%
3.9% 4.2%
4.5%
4.9%
5.0%
3.8% 4.1% 4.5% 4.8%
5.0%
Specified soluble boron concentrations are independent of whether an assembly contains a nonfuel insert.
1 Borated aluminum neutron absorber sheet effective areal 10B density.
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-8 Amendment No. 9 Table B2-5 Additional SNF Assembly Cool Time Required to Load NONFUEL HARDWARE Assembly Pattern A Pattern B Pattern C Storage Location Storage Location Storage Location A
A B
C A
B1 B2 C
CE 14x14 BPAA/HFRA GTPD/NSA RCC 0.2 0.2 0.1 0.2 WE 14x14 BPAA/HFRA 0.5 0.5 0.2 0.7 1.4 0.1 0.1 0.7 GTPD/NSA 0.1 0.1 0.1 0.1 0.2 0.1 0.1 0.1 RCC 0.7 2.3 0.7 4.1 2.2 0.2 0.1 1.0 WE 15x15 BPAA/HFRA 0.5 0.6 0.2 0.8 GTPD/NSA 0.1 0.1 0.1 0.1 RCC 3.1 3.4 1.5 4.5 B&W 15x15 2 BPAA/HFRA 0.1 0.1 0.1 0.1 GTPD/NSA 0.1 0.1 0.1 0.1 RCC 0.2 0.2 0.1 0.2 APSR CE 16x16 BPAA/HFRA GTPD/NSA RCC 0.41 0.2 0.1 0.3 0.8 0.1 0.1 0.4 WE 17x17 BPAA/HFRA 0.5 0.6 0.2 0.7 GTPD/NSA 0.1 0.1 0.1 0.1 RCC 2.9 3.3 1.4 4.3 B&W 17x17 BPAA/HFRA 0.1 0.1 0.1 0.1 GTPD/NSA 0.1 0.1 0.1 0.1 RCC 0.2 0.2 0.1 0.2 Note: Additional SNF assembly cooling time to be added to the minimum SNF assembly cool time based on SNF assembly initial enrichment and SNF assembly average burnup listed in Tables B2-15 through B2-22 and B2-25 through B2-43.
1 0.4 years for RCC in the PMTC (reduced storage location heat load). For all other cask types, 0.3 years for RCC with 5-year minimum cool time or 0.2 years for RCC with 10-year minimum cool time.
2 APSRs are limited to B&W15x15 loaded in a CC6 Concrete Cask in load Patterns E, F, G, and H. Nonfuel hardware heat loads in Patterns E, F, G, and H must be added to fuel assembly heat loads when demonstrating compliance with Table B2-2 fuel storage location limits.
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-9 Amendment No. 9 Table B2-6 Allowed BPAA/NSA Burnup and Cool Time Combinations Maximum Burnup Minimum Cool Time (yrs)
(GWd/MTU)
WE 1414 WE 1515 B&W 1515 WE 1717 B&W 1717 10 0.5 0.5 0.5 0.5 0.5 15 0.5 0.5 0.5 0.5 0.5 20 0.5 1.0 2.0 2.0 0.5 25 1.0 2.5 3.5 3.5 1.0 30 2.5 4.0 5.0 5.0 2.5 32.5 3.0 4.5 6.01 6.0 3.0 35 3.5 5.0 6.0 6.0 3.5 37.5 4.0 6.0 7.0 7.0 4.0 40 4.5 6.0 7.0 7.0 4.5 45 5.0 7.0 8.0 8.0 6.0 50 6.0 8.0 9.0 9.0 7.0 55 7.0 8.0 10.0 9.0 7.0 60 7.0 9.0 10.0 10.0 8.0 65 8.0 10.0 12.0 12.0 8.0 70 8.0 10.0 12.0 12.0 9.0 Max 60 Co Activity (Ci) 718 733 19 637 26 Note: Specified minimum cool times for BPRAs are independent of the required minimum cool times for the fuel assembly containing the BPRA.
1 For use in CC6 a minimum cool time of 1.75 years is permitted.
Table B2-7 Allowed GTPD/NSA Burnup and Cool Time Combinations Maximum Burnup Minimum Cool Time (yrs)
(GWd/MTU)
WE 1414 WE 1515 B&W 1515 WE 1717 B&W 1717 45 2.0 3.5 7.0 5.0 6.0 90 6.0 7.0 10.0 9.0 10.0 135 7.0 9.0 12.0 10.0 12.0 180 8.0 9.0 14.0 12.0 12.0 60Co Activity (Ci) 63.5 64.1 56.9 64.0 63.6 Note: Specified minimum cool times for thimble plugs are independent of the required minimum cool times for the fuel assembly containing the thimble plug.
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-10 Amendment No. 9 Table B2-8 Minimum Cool Time Summary Table Fuel Assembly Heat Load (W) Per Storage Location Load Pattern Applicable Fuel Assembly Load Table Added Cool Time when Loading Nonfuel Hardware Assembly Avg.
Burnup 45 GWd/MTU Assembly Avg.
Burnup
> 45 GWd/MTU 150 F
Note 1 Note 1 Note 1 250 E, F Note 1 Note 1 Note 1 300 G, H Note 1 Note 1 Note 1 350 F
Note 1 Note 1 Note 1 425 E
Note 1 Note 1 Note 1 513 (W14x14)
C Table B2-26 Table B2-30 Table B2-5 513 (CE16x16)
C Table B2-34 Table B2-38 Table B2-5 600 G
Note 1 Note 1 Note 1 650 G
Note 1 Note 1 Note 1 700 G, H Note 1 Note 1 Note 1 750 H
Note 1 Note 1 Note 1 800 B
Table B2-13, Table B2-21 Table B2-22 Table B2-5 800 E, F, G, H Note 1 Note 1 Note 1 811 D
Table B2-42, Table B2-43 Table B2-43 Table B2-5 830 (W14x14)
C Table B2-29 Table B2-33 Table B2-5 830 (W14x14)
C Table B2-37 Table B2-41 Table B2-5 900 E, F Note 1 Note 1 Note 1 922 B
Table B2-13, Table B2-19 Table B2-16, Table B2-20 Table B2-5 950 E, G, H Note 1 Note 1 Note 1 959 A
Table B2-13, Table B2-15 Table B2-16 Table B2-5 959 (W14x14)
A Table B2-25 Table B2-16 Table B2-5 1000 E,F Note 1 Note 1 Note 1 1100 E
Note 1 Note 1 Note 1 1200 B
Table B2-13, Table B2-17 Table B2-18 Table B2-5 1300 (W14x14)
C Table B2-27 Table B2-31 Table B2-5 1300 (CE16x16)
C Table B2-35 Table B2-39 Table B2-5 1300 E
Note 1 Note 1 Note 1 1500 G, H Note 1 Note 1 Note 1 1800 (W14x14)
C Table B2-28 Table B2-32 Table B2-5 1800 (CE16x16)
C Table B2-36 Table B2-40 Table B2-5 1800 F
Note 1 Note 1 Note 1 2000 G, H Note 1 Note 1 Note 1 2050 H
Note 1 Note 1 Note 1 2500 G
Note 1 Note 1 Note 1 2800 F
Note 1 Note 1 Note 1 3,400 E
Note 1 Note 1 Note 1 Note 1: Fuel assembly and non-fuel hardware heat load to be evaluated based on discharged, or bounding, depletion and fuel assembly characteristics and total must be less than or equal to listed limit.
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-11 Amendment No. 9 Figure B2-1 Schematic of 37 - Fuel Storage Location Map DFC designated locations may contain a loaded DFC or a PWR UNDAMAGED SNF ASSEMBLY. Figure applies to PWR Basket and PWR DF Basket.
A1, A2, A3 may be referred to as storage location A when no differentiation of heat load is required between the various locations. Similarly, for group B and C locations.
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-12 Amendment No. 9 Figure B2-2
[DELETED]
Figure B2-3 [DELETED]
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-13 Amendment No. 9 Table B2-9 TSC with BWR Fuel Limits I.
BWR FUEL A. Allowable Contents
- 1. Uranium BWR UNDAMAGED FUEL assemblies listed in Tables B2-10 and B2-11 and meeting the following specifications:
- a. Cladding Type:
Zirconium-based alloy.
- b. Enrichment: Post-irradiation Cooling Time and Assembly Average Burnup Generic maximum INITIAL PEAK PLANAR-AVERAGE ENRICHMENTS are shown in Table B2-10. The physical characteristics of the different BWR SNF ASSEMBLIES are defined in Table B2-11. Fuel type specific enrichment limits for the 87-assembly and 82-assembly BWR fuel basket configurations are defined in Table B2-12 as a function of neutron absorber areal density.
Combined minimum enrichment, maximum SNF assembly average burnup and minimum cool time limits are shown in Table B2-23 and Table B2-24. For SNF assembly average burnup levels below those shown in Table B2-23 and Table B2-24, an SNF assembly minimum cool time is specified in Table B2-14, provided that the minimum initial SNF assembly average enrichment limits are applied.
- c. Decay Heat per SNF Assembly:
379 watts
- d. Nominal Fresh Fuel Design SNF Assembly Length (in.):
176.2
- e. Nominal Fresh Fuel Design SNF Assembly Width (in.):
5.52
- f. SNF Assembly Weight (lb):
704, including channels B. Quantity per TSC: Up to 87 BWR UNDAMAGED SNF ASSEMBLIES. With the exception of the designated nonfuel locations in the 82-assembly basket configuration, fuel storage locations not containing a fuel assembly shall have an empty fuel cell insert installed. Prior to use of the 86 and 82-assembly configurations, the cell fuel storage locations as noted and shown in Figures B2-4 and B2-5 must be physically blocked to prevent fuel assembly loading, respectively.
(continued)
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-14 Amendment No. 9 Table B2-9 TSC with BWR Fuel Limits (continued)
C. BWR fuel assemblies may be unchanneled, or channeled with zirconium-based alloy channels.
D. BWR fuel assemblies with stainless steel channels are not authorized.
E. SNF Assembly lattices possessing less than the nominal number of undamaged fuel rods (see Table B2-11) must contain solid filler rods that displace a volume equal to, or greater than, that of the fuel rod that the filler rod replaces.
F. Spacers may be used in a TSC to axially position BWR SNF assemblies to facilitate handling.
G. Unirradiated (i.e., not inserted in-core) fuel assemblies are not authorized for loading.
Unenriched axial blankets are permitted, provided that the nominal length of the blanket is not greater than six (6) inches.
H. Allowable SNF assembly locations for the 86-assembly fuel basket configuration is shown in Figure B2-4.
I.
Allowable SNF assembly locations for the standard and alternate 82-assembly fuel basket configurations are shown in Figure B2-5.
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-15 Amendment No. 9 Table B2-10 BWR SNF Assembly Characteristics Characteristic Fuel Class 7x7 8x8 9x9 10x10 Max Initial Enrichment (wt % 235U) 4.5 4.5 4.5 4.5 Number of Fuel Rods 48/49 59/60/61/
62/63/64 72/74((a)/76/
79/80 91(a)/92(a)/
96(a)/100 Max Assembly Average Burnup (MWd/MTU) 60,000 60,000 60,000 60,000 Peak Average Rod Burnup (MWd/MTU) 62,500 62,500 62,500 62,500 Min Cool Time (years) 4 4
4 4
Min Average Enrichment (wt % 235U) 0.7 0.7 0.7 0.7 Max Weight (lb) per Storage Location 704 704 704 704 Max Decay Heat (Watts) per Storage Location 379 379 379 379 Each BWR fuel assembly may include a zirconium-based alloy channel.
Assembly weight includes the weight of the channel.
Maximum initial enrichment is the peak planar-average enrichment.
Water rods may occupy more than one fuel lattice location. Fuel assembly to contain nominal number of water rods for the specific assembly design.
All enrichment values are nominal preirradiation fabrication values.
Spacers may be used to axially position fuel assemblies to facilitate handling.
(a) Assemblies may contain partial-length fuel rods.
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-16 Amendment No. 9 Table B2-11 BWR SNF Assembly Loading Criteria Geometry 3,4 Assembly Type Number of Fuel Rods Number of Partial Length Rods 1 Max Pitch (inch)
Min Clad OD (inch)
Min Clad Thick.
(inch)
Max Pellet OD (inch)
Max Active Length (inch)
Max Loading (MTU)
B7_48A 48 N/A 0.7380 0.5700 0.03600 0.4900 144.0 0.1981 B7_49A 49 N/A 0.7380 0.5630 0.03200 0.4880 146.0 0.2034 B7_49B 49 N/A 0.7380 0.5630 0.03200 0.4910 150.0 0.2115 B8_59A 59 N/A 0.6400 0.4930 0.03400 0.4160 150.0 0.1828 B8_60A 60 N/A 0.6417 0.4840 0.03150 0.4110 150.0 0.1815 B8_60B 60 N/A 0.6400 0.4830 0.03000 0.4140 150.0 0.1841 B8_61B 61 N/A 0.6400 0.4830 0.03000 0.4140 150.0 0.1872 B8_62A 62 N/A 0.6417 0.4830 0.02900 0.4160 150.0 0.1921 B8_63A 63 N/A 0.6420 0.4840 0.02725 0.4195 150.0 0.1985 B8_64A 64 N/A 0.6420 0.4840 0.02725 0.4195 150.0 0.2017 B8_64B5 64 N/A 0.6090 0.4576 0.02900 0.3913 150.0 0.1755 B9_72A 72 N/A 0.5720 0.4330 0.02600 0.3740 150.0 0.1803 B9_74A 742 8
0.5720 0.4240 0.02390 0.3760 150.0 0.1873 B9_76A 76 N/A 0.5720 0.4170 0.02090 0.3750 150.0 0.1914 B9_79A 79 N/A 0.5720 0.4240 0.02390 0.3760 150.0 0.2000 B9_80A 80 N/A 0.5720 0.4230 0.02950 0.3565 150.0 0.1821 B10_91A 912 8
0.5100 0.3957 0.02385 0.3420 150.0 0.1906 B10_92A 922 14 0.5100 0.4040 0.02600 0.3455 150.0 0.1966 B10_96A5 962 12 0.4880 0.3780 0.02430 0.3224 150.0 0.1787 B10_100A5 100 N/A 0.4880 0.3780 0.02430 0.3224 150.0 0.1861 1 Location of the partial length rods is illustrated in Figure B2-6.
2 Assemblies may contain partial-length fuel rods.
3 Assembly characteristics represent cold, unirradiated, nominal configurations.
4 Maximum channel thickness allowed is 120 mils (nominal).
5 Composed of four subchannel clusters.
Note: Amendment No. 2 removed the enrichment/soluble boron limits from this table. This information is now presented in Table B2-12.
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-17 Amendment No. 9 Table B2-12 BWR SNF Assembly Loading Criteria - Enrichment Limits for 87-Assembly and 82-Assembly Configurations Max. Initial Enrichmenta ( wt % 235U)
Absorberb 0.027 10B g/cm2 Absorber 0.0225 10B g/cm2 Absorber 0.02 10B g/cm2 87-Assy Basket 82-Assy Basket 87-Assy Basket 82-Assy Basket 87-Assy Basket 82-Assy Basket B7_48A 4.0%
4.5%
3.7%
4.5%
3.6%
4.4%
B7_49A 3.8%
4.5%
3.6%
4.4%
3.5%
4.3%
B7_49B 3.8%
4.5%
3.6%
4.4%
3.5%
4.2%
B8_59A 3.9%
4.5%
3.7%
4.5%
3.6%
4.3%
B8_60A 3.8%
4.5%
3.7%
4.4%
3.5%
4.2%
B8_60B 3.8%
4.5%
3.6%
4.3%
3.5%
4.2%
B8_61B 3.8%
4.5%
3.6%
4.3%
3.5%
4.2%
B8_62A 3.8%
4.5%
3.6%
4.3%
3.5%
4.1%
B8_63A 3.8%
4.5%
3.6%
4.3%
3.4%
4.2%
B8_64A 3.8%
4.5%
3.6%
4.3%
3.5%
4.2%
B8_64B 3.6%
4.3%
3.4%
4.1%
3.3%
4.0%
B9_72A 3.8%
4.5%
3.6%
4.3%
3.4%
4.1%
B9_74A 3.7% c 4.3%
3.4%
4.1%
3.4%
4.0%
B9_76A 3.5%
4.2%
3.4%
4.0%
3.3%
3.9%
B9_79A 3.7%
4.4%
3.4%
4.2%
3.3%
4.0%
B9_80A 3.8%
4.5%
3.6%
4.3%
3.5%
4.2%
B10_91A 3.7%
4.5%d 3.6%
4.3%
3.5%
4.1%
B10_92A 3.8%
4.5%d 3.6%
4.3%
3.5%
4.1%
B10_96A 3.7%
4.3%
3.5%
4.1%
3.4%
4.0%
B10_100A 3.6%
4.4%
3.5%
4.1%
3.4%
4.0%
a Maximum planar average.
b Borated aluminum neutron absorber sheet effective areal 10B density.
c 3.85% in the 86-assembly basket configuration d 4.55% in the alternate 82-assembly basket configuration
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-18 Amendment No. 9 Figure B2-4 Schematic of 87-Assembly BWR Basket Note - Cell location 44 must have an empty fuel cell insert installed in order to use the 86-assembly configuration.
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-19 Amendment No. 9 Figure B2-5 Schematic of 82-Assembly BWR Basket
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-20 Amendment No. 9 Figure B2-6 BWR Partial Length Fuel Rod Location Sketches B9_74A 8 Partial Length Rods B10_91A 8 Partial Length Rods B10_92A 14 Partial Length Rods B10_96A 12 Partial Length Rods
= Fuel Rod Location
= Partial Rod Location
= Fuel Rod Location
= Partial Rod Location
= Fuel Rod Location
= Partial Rod Location
= Partial Rod Location
= Fuel Rod Location
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-21 Amendment No. 9 Table B2-13 PWR Loading Table - Low SNF Assembly Average Burnup Enrichment Limits Max. Assembly Avg.
Burnup (MWd/MTU)
Min. Assembly Avg.
Initial Enrichment (wt% 235U)
Minimum Cool Time (yrs)
Heat Load per Assy 959 W 800 W 922 W 1,200 W 10,000 1.3 4.0 4.0 4.0 4.0 15,000 1.5 4.0 4.0 4.0 4.0 20,000 1.7 4.0 4.0 4.0 4.0 25,000 1.9 4.0 4.3 4.0 4.0 30,000 2.1 4.4 5.2 4.5 4.0 Table B2-14 BWR Loading Table - Low SNF Assembly Average Burnup Enrichment Limits Max. Assembly Avg.
Burnup (MWd/MTU)
Min. Assembly Avg.
Initial Enrichment (wt% 235U)
Minimum Cool Time (yrs) 5,000 0.7 4.0 10,000 1.3 4.0 15,000 1.5 4.0 20,000 1.7 4.0 25,000 1.9 4.0 30,000 2.1 4.3
Appendix B Approved Contents Certificate of Compliance No.1031 B2-22 Amendment No. 9 Table B2-15 Loading Table for PWR Fuel - 959 W/Assembly Initial Assembly Avg. Enrichment wt % 235U (E) 30 < Assembly Average Burnup 32.5 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 4.1 4.1 4.6 4.7 4.4 4.7 4.7 2.3 E < 2.5 4.0 4.1 4.5 4.7 4.4 4.6 4.6 2.5 E < 2.7 4.0 4.0 4.5 4.6 4.3 4.6 4.6 2.7 E < 2.9 4.0 4.0 4.5 4.5 4.3 4.5 4.5 2.9 E < 3.1 4.0 4.0 4.4 4.5 4.2 4.5 4.5 3.1 E < 3.3 4.0 4.0 4.4 4.5 4.2 4.5 4.5 3.3 E < 3.5 4.0 4.0 4.3 4.4 4.2 4.4 4.4 3.5 E < 3.7 4.0 4.0 4.3 4.4 4.1 4.4 4.4 3.7 E < 3.9 4.0 4.0 4.3 4.4 4.1 4.4 4.4 3.9 E < 4.1 4.0 4.0 4.2 4.3 4.0 4.3 4.3 4.1 E < 4.3 4.0 4.0 4.2 4.3 4.0 4.3 4.3 4.3 E < 4.5 4.0 4.0 4.2 4.3 4.0 4.3 4.3 4.5 E < 4.7 4.0 4.0 4.1 4.2 4.0 4.2 4.2 4.7 E < 4.9 4.0 4.0 4.1 4.2 4.0 4.2 4.2 E 4.9 4.0 4.0 4.1 4.2 4.0 4.2 4.2 Initial Assembly Avg. Enrichment wt % 235U (E) 32.5 < Assembly Average Burnup 35 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 4.3 4.4 5.0 5.1 4.7 5.0 5.0 2.5 E < 2.7 4.3 4.4 4.9 5.0 4.7 5.0 5.0 2.7 E < 2.9 4.2 4.3 4.8 5.0 4.6 4.9 4.9 2.9 E < 3.1 4.2 4.3 4.8 4.9 4.6 4.9 4.9 3.1 E < 3.3 4.1 4.2 4.7 4.9 4.5 4.8 4.8 3.3 E < 3.5 4.1 4.2 4.7 4.8 4.5 4.8 4.8 3.5 E < 3.7 4.1 4.1 4.6 4.8 4.4 4.7 4.7 3.7 E < 3.9 4.0 4.1 4.6 4.7 4.4 4.7 4.7 3.9 E < 4.1 4.0 4.1 4.6 4.7 4.4 4.7 4.7 4.1 E < 4.3 4.0 4.0 4.5 4.7 4.3 4.6 4.6 4.3 E < 4.5 4.0 4.0 4.5 4.6 4.3 4.6 4.6 4.5 E < 4.7 4.0 4.0 4.5 4.6 4.3 4.6 4.6 4.7 E < 4.9 4.0 4.0 4.4 4.6 4.3 4.5 4.5 E 4.9 4.0 4.0 4.4 4.5 4.2 4.5 4.5
Appendix B Approved Contents Certificate of Compliance No.1031 B2-23 Amendment No. 9 Table B2-15 Loading Table for PWR Fuel - 959 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 35 < Assembly Average Burnup 37.5 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 4.7 4.8 5.5 5.7 5.2 5.6 5.6 2.5 E < 2.7 4.6 4.7 5.4 5.6 5.1 5.5 5.5 2.7 E < 2.9 4.6 4.7 5.3 5.5 5.0 5.4 5.4 2.9 E < 3.1 4.5 4.6 5.3 5.4 5.0 5.4 5.4 3.1 E < 3.3 4.5 4.5 5.2 5.4 4.9 5.3 5.3 3.3 E < 3.5 4.4 4.5 5.1 5.3 4.9 5.2 5.2 3.5 E < 3.7 4.4 4.5 5.0 5.2 4.8 5.2 5.2 3.7 E < 3.9 4.3 4.4 5.0 5.2 4.8 5.1 5.1 3.9 E < 4.1 4.3 4.4 5.0 5.1 4.7 5.1 5.1 4.1 E < 4.3 4.3 4.4 4.9 5.1 4.7 5.0 5.0 4.3 E < 4.5 4.2 4.3 4.9 5.0 4.7 5.0 5.0 4.5 E < 4.7 4.2 4.3 4.9 5.0 4.6 5.0 5.0 4.7 E < 4.9 4.2 4.3 4.8 5.0 4.6 4.9 4.9 E 4.9 4.1 4.2 4.8 4.9 4.5 4.9 4.9 Initial Assembly Avg. Enrichment wt % 235U (E) 37.5 < Assembly Average Burnup 40 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 5.0 5.2 5.9 6.1 5.6 6.0 6.0 2.7 E < 2.9 5.0 5.1 5.9 6.0 5.5 5.9 5.9 2.9 E < 3.1 4.9 5.0 5.8 6.0 5.5 5.9 5.9 3.1 E < 3.3 4.9 4.9 5.7 5.9 5.4 5.8 5.8 3.3 E < 3.5 4.8 4.9 5.7 5.8 5.3 5.7 5.7 3.5 E < 3.7 4.7 4.8 5.6 5.8 5.2 5.7 5.7 3.7 E < 3.9 4.7 4.8 5.5 5.7 5.2 5.6 5.6 3.9 E < 4.1 4.6 4.8 5.5 5.7 5.1 5.6 5.6 4.1 E < 4.3 4.6 4.7 5.4 5.6 5.1 5.5 5.5 4.3 E < 4.5 4.5 4.7 5.4 5.6 5.0 5.5 5.5 4.5 E < 4.7 4.5 4.6 5.3 5.5 5.0 5.4 5.4 4.7 E < 4.9 4.5 4.6 5.3 5.5 5.0 5.4 5.4 E 4.9 4.5 4.5 5.2 5.4 4.9 5.4 5.4
Appendix B Approved Contents Certificate of Compliance No.1031 B2-24 Amendment No. 9 Table B2-15 Loading Table for PWR Fuel - 959 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 40 < Assembly Average Burnup 41 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 5.3 5.4 6.2 6.4 5.8 6.3 6.3 2.7 E < 2.9 5.2 5.3 6.1 6.3 5.7 6.2 6.2 2.9 E < 3.1 5.1 5.2 6.0 6.2 5.7 6.1 6.1 3.1 E < 3.3 5.0 5.1 5.9 6.1 5.6 6.0 6.0 3.3 E < 3.5 4.9 5.1 5.9 6.0 5.5 5.9 5.9 3.5 E < 3.7 4.9 5.0 5.8 6.0 5.5 5.9 5.9 3.7 E < 3.9 4.8 4.9 5.7 5.9 5.4 5.8 5.8 3.9 E < 4.1 4.8 4.9 5.7 5.9 5.3 5.8 5.8 4.1 E < 4.3 4.7 4.9 5.6 5.8 5.3 5.7 5.7 4.3 E < 4.5 4.7 4.8 5.6 5.8 5.2 5.7 5.7 4.5 E < 4.7 4.7 4.8 5.5 5.7 5.2 5.6 5.6 4.7 E < 4.9 4.6 4.7 5.5 5.7 5.1 5.6 5.6 E 4.9 4.6 4.7 5.5 5.6 5.1 5.6 5.6 Initial Assembly Avg. Enrichment wt % 235U (E) 41 < Assembly Average Burnup 42 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 5.5 5.6 6.5 6.7 6.0 6.6 6.6 2.7 E < 2.9 5.4 5.5 6.4 6.6 5.9 6.5 6.5 2.9 E < 3.1 5.3 5.4 6.3 6.5 5.9 6.4 6.4 3.1 E < 3.3 5.2 5.3 6.2 6.4 5.8 6.3 6.3 3.3 E < 3.5 5.1 5.3 6.1 6.3 5.7 6.2 6.2 3.5 E < 3.7 5.0 5.2 6.0 6.2 5.7 6.1 6.1 3.7 E < 3.9 5.0 5.1 5.9 6.2 5.6 6.0 6.0 3.9 E < 4.1 4.9 5.1 5.9 6.1 5.5 6.0 6.0 4.1 E < 4.3 4.9 5.0 5.8 6.0 5.5 5.9 5.9 4.3 E < 4.5 4.9 5.0 5.8 6.0 5.4 5.9 5.9 4.5 E < 4.7 4.8 4.9 5.7 5.9 5.4 5.8 5.8 4.7 E < 4.9 4.8 4.9 5.7 5.9 5.3 5.8 5.8 E 4.9 4.7 4.9 5.7 5.9 5.3 5.8 5.8
Appendix B Approved Contents Certificate of Compliance No.1031 B2-25 Amendment No. 9 Table B2-15 Loading Table for PWR Fuel - 959 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 42 < Assembly Average Burnup 43 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 5.7 5.8 6.8 7.0 6.3 6.9 6.9 2.7 E < 2.9 5.6 5.7 6.7 6.9 6.2 6.8 6.8 2.9 E < 3.1 5.5 5.6 6.6 6.8 6.0 6.7 6.7 3.1 E < 3.3 5.4 5.6 6.5 6.7 6.0 6.6 6.6 3.3 E < 3.5 5.3 5.5 6.4 6.6 5.9 6.5 6.5 3.5 E < 3.7 5.3 5.4 6.3 6.5 5.9 6.4 6.4 3.7 E < 3.9 5.2 5.3 6.2 6.5 5.8 6.3 6.3 3.9 E < 4.1 5.1 5.3 6.1 6.4 5.7 6.2 6.2 4.1 E < 4.3 5.0 5.2 6.0 6.3 5.7 6.2 6.1 4.3 E < 4.5 5.0 5.2 6.0 6.2 5.6 6.1 6.1 4.5 E < 4.7 5.0 5.1 5.9 6.2 5.6 6.0 6.0 4.7 E < 4.9 4.9 5.0 5.9 6.1 5.5 6.0 6.0 E 4.9 4.9 5.0 5.8 6.0 5.5 6.0 5.9 Initial Assembly Avg. Enrichment wt % 235U (E) 43 < Assembly Average Burnup 44 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 5.9 6.0 7.1 7.4 6.6 7.2 7.2 2.7 E < 2.9 5.8 5.9 7.0 7.3 6.5 7.0 7.0 2.9 E < 3.1 5.7 5.8 6.9 7.1 6.4 6.9 6.9 3.1 E < 3.3 5.6 5.8 6.8 7.0 6.2 6.8 6.8 3.3 E < 3.5 5.5 5.7 6.7 6.9 6.1 6.8 6.7 3.5 E < 3.7 5.5 5.6 6.6 6.8 6.0 6.7 6.7 3.7 E < 3.9 5.4 5.6 6.5 6.8 6.0 6.6 6.6 3.9 E < 4.1 5.3 5.5 6.4 6.7 5.9 6.5 6.5 4.1 E < 4.3 5.3 5.4 6.3 6.6 5.9 6.4 6.4 4.3 E < 4.5 5.2 5.4 6.2 6.5 5.8 6.4 6.4 4.5 E < 4.7 5.1 5.3 6.2 6.5 5.8 6.3 6.3 4.7 E < 4.9 5.1 5.3 6.1 6.4 5.7 6.2 6.2 E 4.9 5.0 5.2 6.0 6.3 5.7 6.2 6.2
Appendix B Approved Contents Certificate of Compliance No.1031 B2-26 Amendment No. 9 Table B2-15 Loading Table for PWR Fuel - 959 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 44 < Assembly Average Burnup 45 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 6.0 6.2 7.3 7.7 6.7 7.4 7.4 2.9 E < 3.1 5.9 6.0 7.2 7.6 6.6 7.3 7.3 3.1 E < 3.3 5.8 6.0 7.0 7.4 6.5 7.2 7.1 3.3 E < 3.5 5.7 5.9 6.9 7.3 6.4 7.0 7.0 3.5 E < 3.7 5.7 5.8 6.8 7.2 6.3 6.9 6.9 3.7 E < 3.9 5.6 5.8 6.8 7.0 6.2 6.9 6.9 3.9 E < 4.1 5.5 5.7 6.7 7.0 6.2 6.8 6.8 4.1 E < 4.3 5.5 5.6 6.6 6.9 6.1 6.7 6.7 4.3 E < 4.5 5.4 5.6 6.5 6.8 6.0 6.7 6.6 4.5 E < 4.7 5.3 5.5 6.5 6.7 6.0 6.6 6.6 4.7 E < 4.9 5.3 5.5 6.4 6.7 5.9 6.5 6.5 E 4.9 5.2 5.4 6.3 6.6 5.9 6.5 6.5
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-27 Amendment No. 9 Note: For fuel assembly average burnup greater than 45 GWd/MTU, cool time tables have been revised to account for a 5% margin in heat load.
Table B2-16 Loading Table for PWR Fuel - 911 W/Assembly Initial Assembly Avg. Enrichment wt % 235U (E) 45 < Assembly Average Burnup 46 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 6.7 6.9 8.5 9.0 7.7 8.6 8.6 2.9 E < 3.1 6.6 6.8 8.3 8.8 7.5 8.4 8.4 3.1 E < 3.3 6.5 6.7 8.1 8.6 7.4 8.2 8.2 3.3 E < 3.5 6.4 6.6 8.0 8.5 7.3 8.1 8.1 3.5 E < 3.7 6.3 6.5 7.8 8.3 7.1 8.0 7.9 3.7 E < 3.9 6.2 6.4 7.7 8.2 7.0 7.8 7.8 3.9 E < 4.1 6.1 6.3 7.6 8.0 6.9 7.7 7.7 4.1 E < 4.3 6.0 6.2 7.5 7.9 6.9 7.7 7.6 4.3 E < 4.5 6.0 6.2 7.4 7.8 6.8 7.6 7.6 4.5 E < 4.7 5.9 6.1 7.3 7.8 6.7 7.5 7.5 4.7 E < 4.9 5.9 6.0 7.2 7.7 6.7 7.4 7.4 E 4.9 5.8 6.0 7.2 7.6 6.6 7.3 7.3
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-28 Amendment No. 9 Table B2-16 Loading Table for PWR Fuel - 911 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 46 < Assembly Average Burnup 47 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 7.0 7.3 9.0 9.6 8.0 9.1 9.1 2.9 E < 3.1 6.9 7.1 8.8 9.4 7.9 8.9 8.9 3.1 E < 3.3 6.8 7.0 8.6 9.2 7.8 8.7 8.7 3.3 E < 3.5 6.7 6.9 8.4 9.0 7.6 8.6 8.6 3.5 E < 3.7 6.6 6.8 8.3 8.8 7.5 8.4 8.4 3.7 E < 3.9 6.5 6.7 8.1 8.7 7.4 8.3 8.3 3.9 E < 4.1 6.4 6.6 8.0 8.5 7.3 8.1 8.1 4.1 E < 4.3 6.3 6.5 7.9 8.4 7.2 8.0 8.0 4.3 E < 4.5 6.2 6.5 7.8 8.3 7.1 7.9 7.9 4.5 E < 4.7 6.1 6.4 7.7 8.2 7.0 7.9 7.8 4.7 E < 4.9 6.0 6.3 7.6 8.1 6.9 7.8 7.8 E 4.9 6.0 6.2 7.6 8.0 6.9 7.7 7.7 Initial Assembly Avg. Enrichment wt % 235U (E) 47 < Assembly Average Burnup 48 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 7.4 7.7 9.6 10.3 8.6 9.7 9.7 2.9 E < 3.1 7.2 7.6 9.4 10.0 8.4 9.5 9.5 3.1 E < 3.3 7.1 7.4 9.1 9.8 8.2 9.3 9.3 3.3 E < 3.5 7.0 7.2 8.9 9.6 8.0 9.1 9.0 3.5 E < 3.7 6.9 7.1 8.8 9.4 7.9 8.9 8.9 3.7 E < 3.9 6.7 7.0 8.6 9.2 7.8 8.8 8.7 3.9 E < 4.1 6.7 6.9 8.5 9.0 7.6 8.6 8.6 4.1 E < 4.3 6.6 6.8 8.4 8.9 7.6 8.5 8.5 4.3 E < 4.5 6.5 6.7 8.2 8.8 7.4 8.4 8.4 4.5 E < 4.7 6.4 6.7 8.1 8.7 7.4 8.3 8.3 4.7 E < 4.9 6.3 6.6 8.0 8.6 7.3 8.2 8.2 E 4.9 6.2 6.5 7.9 8.5 7.2 8.1 8.1
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-29 Amendment No. 9 Table B2-16 Loading Table for PWR Fuel - 911 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 48 < Assembly Average Burnup 49 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 7.8 8.1 10.2 11.1 9.0 10.4 10.4 2.9 E < 3.1 7.6 7.9 10.0 10.8 8.8 10.1 10.1 3.1 E < 3.3 7.5 7.8 9.7 10.5 8.6 9.9 9.8 3.3 E < 3.5 7.3 7.6 9.5 10.2 8.5 9.7 9.6 3.5 E < 3.7 7.2 7.5 9.3 10.0 8.3 9.5 9.4 3.7 E < 3.9 7.0 7.4 9.1 9.8 8.2 9.3 9.3 3.9 E < 4.1 6.9 7.2 9.0 9.6 8.0 9.1 9.1 4.1 E < 4.3 6.8 7.1 8.8 9.5 7.9 9.0 9.0 4.3 E < 4.5 6.8 7.0 8.7 9.3 7.8 8.9 8.9 4.5 E < 4.7 6.7 6.9 8.6 9.2 7.7 8.8 8.7 4.7 E < 4.9 6.6 6.9 8.5 9.1 7.6 8.7 8.6 E 4.9 6.5 6.8 8.4 9.0 7.6 8.6 8.5 Initial Assembly Avg. Enrichment wt % 235U (E) 49 < Assembly Average Burnup 50 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 8.0 8.3 10.7 11.6 9.4 10.9 10.9 3.1 E < 3.3 7.8 8.1 10.4 11.3 9.1 10.6 10.6 3.3 E < 3.5 7.7 7.9 10.1 11.0 9.0 10.3 10.3 3.5 E < 3.7 7.5 7.8 9.9 10.8 8.8 10.0 10.0 3.7 E < 3.9 7.4 7.6 9.7 10.5 8.6 9.9 9.9 3.9 E < 4.1 7.3 7.5 9.5 10.3 8.5 9.7 9.7 4.1 E < 4.3 7.1 7.4 9.4 10.1 8.3 9.6 9.5 4.3 E < 4.5 7.0 7.3 9.2 9.9 8.2 9.4 9.4 4.5 E < 4.7 6.9 7.2 9.1 9.8 8.1 9.3 9.2 4.7 E < 4.9 6.9 7.1 9.0 9.6 8.0 9.1 9.1 E 4.9 6.8 7.0 8.9 9.5 7.9 9.0 9.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-30 Amendment No. 9 Table B2-16 Loading Table for PWR Fuel - 911 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 50 < Assembly Average Burnup 51 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 8.3 8.7 11.5 12.3 10.0 11.6 11.6 3.1 E < 3.3 8.0 8.5 11.2 12.0 9.8 11.3 11.3 3.3 E < 3.5 7.9 8.3 10.9 11.7 9.5 11.1 11.1 3.5 E < 3.7 7.8 8.1 10.6 11.5 9.3 10.8 10.8 3.7 E < 3.9 7.6 8.0 10.4 11.3 9.1 10.6 10.6 3.9 E < 4.1 7.5 7.9 10.1 11.1 9.0 10.4 10.4 4.1 E < 4.3 7.4 7.8 10.0 10.9 8.8 10.2 10.1 4.3 E < 4.5 7.3 7.6 9.8 10.6 8.7 10.0 10.0 4.5 E < 4.7 7.1 7.5 9.7 10.5 8.6 9.8 9.8 4.7 E < 4.9 7.0 7.4 9.5 10.3 8.5 9.7 9.7 E 4.9 7.0 7.3 9.4 10.1 8.3 9.6 9.6 Initial Assembly Avg. Enrichment wt % 235U (E) 51 < Assembly Average Burnup 52 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 8.8 9.3 12.2 13.0 10.7 12.4 12.4 3.1 E < 3.3 8.5 9.0 11.9 12.6 10.4 12.1 12.0 3.3 E < 3.5 8.3 8.8 11.6 12.3 10.1 11.8 11.8 3.5 E < 3.7 8.1 8.6 11.4 11.9 9.9 11.6 11.5 3.7 E < 3.9 8.0 8.5 11.1 11.7 9.7 11.3 11.3 3.9 E < 4.1 7.9 8.3 10.9 11.5 9.5 11.1 11.1 4.1 E < 4.3 7.7 8.1 10.7 11.3 9.3 10.9 10.9 4.3 E < 4.5 7.6 8.0 10.5 11.1 9.2 10.7 10.7 4.5 E < 4.7 7.5 7.9 10.3 11.0 9.0 10.5 10.5 4.7 E < 4.9 7.4 7.8 10.1 10.8 8.9 10.3 10.3 E 4.9 7.3 7.7 10.0 10.6 8.8 10.2 10.2
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-31 Amendment No. 9 Table B2-16 Loading Table for PWR Fuel - 911 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 52 < Assembly Average Burnup 53 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 9.3 9.8 12.8 13.8 11.4 13.3 13.3 3.1 E < 3.3 9.0 9.6 12.4 13.5 11.2 13.0 13.0 3.3 E < 3.5 8.8 9.3 12.1 13.2 10.9 12.6 12.6 3.5 E < 3.7 8.6 9.1 11.8 12.8 10.6 12.3 12.3 3.7 E < 3.9 8.4 9.0 11.5 12.6 10.3 12.0 12.0 3.9 E < 4.1 8.2 8.8 11.3 12.3 10.1 11.8 11.8 4.1 E < 4.3 8.1 8.6 11.1 12.0 9.9 11.6 11.6 4.3 E < 4.5 8.0 8.5 10.9 11.8 9.7 11.4 11.4 4.5 E < 4.7 7.9 8.3 10.7 11.7 9.6 11.2 11.2 4.7 E < 4.9 7.8 8.2 10.6 11.5 9.4 11.1 11.0 E 4.9 7.7 8.1 10.4 11.3 9.3 10.9 10.9 Initial Assembly Avg. Enrichment wt % 235U (E) 53 < Assembly Average Burnup 54 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 9.8 10.5 13.6 14.9 12.2 14.2 14.2 3.1 E < 3.3 9.6 10.2 13.3 14.4 11.8 13.8 13.8 3.3 E < 3.5 9.3 9.9 12.9 14.0 11.6 13.5 13.5 3.5 E < 3.7 9.1 9.7 12.6 13.7 11.3 13.2 13.2 3.7 E < 3.9 8.9 9.5 12.3 13.4 11.0 12.9 12.9 3.9 E < 4.1 8.7 9.3 12.0 13.2 10.8 12.6 12.6 4.1 E < 4.3 8.6 9.1 11.8 12.9 10.6 12.4 12.4 4.3 E < 4.5 8.4 8.9 11.6 12.6 10.4 12.1 12.1 4.5 E < 4.7 8.3 8.8 11.4 12.4 10.1 11.9 11.9 4.7 E < 4.9 8.1 8.7 11.3 12.2 10.0 11.8 11.7 E 4.9 8.0 8.8 11.1 12.0 9.9 11.6 11.6
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-32 Amendment No. 9 Table B2-16 Loading Table for PWR Fuel - 911 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 54 < Assembly Average Burnup 55 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 10.1 10.9 14.1 15.4 12.7 14.8 14.8 3.3 E < 3.5 9.9 10.6 13.8 15.0 12.3 14.4 14.4 3.5 E < 3.7 9.6 10.3 13.5 14.7 12.0 14.0 14.0 3.7 E < 3.9 9.4 10.1 13.1 14.3 11.8 13.8 13.8 3.9 E < 4.1 9.2 9.8 12.9 14.0 11.5 13.5 13.5 4.1 E < 4.3 9.0 9.7 12.6 13.8 11.3 13.3 13.2 4.3 E < 4.5 8.9 9.5 12.3 13.5 11.1 13.0 13.0 4.5 E < 4.7 8.7 9.3 12.1 13.3 10.9 12.8 12.7 4.7 E < 4.9 8.6 9.1 11.9 13.1 10.7 12.6 12.5 E 4.9 8.5 9.0 11.7 12.9 10.5 12.3 12.3 Initial Assembly Avg. Enrichment wt % 235U (E) 55 < Assembly Average Burnup 56 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 10.9 11.6 15.1 16.5 13.1 15.8 15.8 3.3 E < 3.5 10.5 11.3 14.7 16.0 12.8 15.4 15.4 3.5 E < 3.7 10.2 11.0 14.3 15.7 12.4 15.1 15.0 3.7 E < 3.9 9.9 10.8 14.0 15.3 12.1 14.7 14.7 3.9 E < 4.1 9.7 10.5 13.7 15.0 11.9 14.4 14.4 4.1 E < 4.3 9.5 10.2 13.4 14.7 11.7 14.1 14.1 4.3 E < 4.5 9.3 10.0 13.2 14.5 11.4 13.8 13.8 4.5 E < 4.7 9.2 9.9 12.9 14.2 11.2 13.6 13.6 4.7 E < 4.9 9.0 9.7 12.7 13.9 11.1 13.4 13.4 E 4.9 8.9 9.5 12.5 13.8 10.9 13.2 13.2
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-33 Amendment No. 9 Table B2-16 Loading Table for PWR Fuel - 911 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 56 < Assembly Average Burnup 57 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 11.5 12.3 16.0 17.4 14.0 16.8 16.8 3.3 E < 3.5 11.2 12.0 15.6 17.1 13.6 16.4 16.4 3.5 E < 3.7 10.9 11.7 15.3 16.7 13.3 16.0 16.0 3.7 E < 3.9 10.6 11.4 14.9 16.3 13.0 15.7 15.6 3.9 E < 4.1 10.3 11.2 14.6 16.0 12.6 15.4 15.3 4.1 E < 4.3 10.1 10.9 14.2 15.7 12.4 15.1 15.1 4.3 E < 4.5 9.9 10.7 14.0 15.4 12.1 14.8 14.8 4.5 E < 4.7 9.7 10.5 13.8 15.2 11.9 14.5 14.5 4.7 E < 4.9 9.5 10.3 13.6 14.9 11.7 14.2 14.2 E 4.9 9.4 10.1 13.4 14.7 11.5 14.0 14.0 Initial Assembly Avg. Enrichment wt % 235U (E) 57 < Assembly Average Burnup 58 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 12.2 13.2 17.0 18.5 14.9 17.8 17.7 3.3 E < 3.5 11.9 12.8 16.7 18.1 14.5 17.4 17.4 3.5 E < 3.7 11.6 12.4 16.2 17.7 14.1 17.0 17.0 3.7 E < 3.9 11.3 12.1 15.9 17.3 13.8 16.7 16.6 3.9 E < 4.1 11.0 11.9 15.6 17.0 13.5 16.3 16.3 4.1 E < 4.3 10.7 11.6 15.3 16.7 13.2 16.0 16.0 4.3 E < 4.5 10.5 11.4 15.0 16.4 12.9 15.7 15.7 4.5 E < 4.7 10.3 11.2 14.7 16.1 12.7 15.5 15.4 4.7 E < 4.9 10.0 10.9 14.4 15.8 12.4 15.2 15.2 E 4.9 9.9 10.8 14.2 15.6 12.2 15.0 14.9
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-34 Amendment No. 9 Table B2-16 Loading Table for PWR Fuel - 911 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 58 < Assembly Average Burnup 59 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 13.0 14.0 18.0 19.5 15.8 18.8 18.8 3.3 E < 3.5 12.6 13.6 17.6 19.1 15.4 18.4 18.4 3.5 E < 3.7 12.2 13.3 17.2 18.7 15.0 18.0 18.0 3.7 E < 3.9 11.9 12.9 16.9 18.3 14.6 17.7 17.7 3.9 E < 4.1 11.6 12.6 16.5 18.0 14.3 17.4 17.3 4.1 E < 4.3 11.4 12.3 16.2 17.7 14.0 17.0 17.0 4.3 E < 4.5 11.1 12.0 15.9 17.4 13.7 16.7 16.7 4.5 E < 4.7 10.9 11.8 15.6 17.1 13.5 16.4 16.4 4.7 E < 4.9 10.7 11.6 15.4 16.8 13.2 16.1 16.1 E 4.9 10.5 11.4 15.1 16.6 13.0 15.9 15.9 Initial Assembly Avg. Enrichment wt % 235U (E) 59 < Assembly Average Burnup 60 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 3.3 E < 3.5 13.4 14.4 18.6 20.1 16.3 19.0 19.0 3.5 E < 3.7 13.0 14.1 18.2 19.7 15.9 18.6 18.5 3.7 E < 3.9 12.7 13.7 17.8 19.4 15.5 18.2 18.1 3.9 E < 4.1 12.3 13.4 17.5 19.0 15.2 17.9 17.8 4.1 E < 4.3 12.0 13.1 17.1 18.7 14.9 17.5 17.5 4.3 E < 4.5 11.8 12.8 16.8 18.4 14.6 17.2 17.2 4.5 E < 4.7 11.6 12.6 16.5 18.0 14.3 16.9 16.9 4.7 E < 4.9 11.3 12.3 16.2 17.8 14.0 16.6 16.6 E 4.9 11.2 12.1 16.0 17.6 13.8 16.4 16.3
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-35 Amendment No. 9 Table B2-17 Loading Table for PWR Fuel - 1,200 W/Assembly Initial Assembly Avg. Enrichment wt % 235U (E) 30 < Assembly Average Burnup 32.5 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 4.0 4.0 4.0 4.0 4.0 4.0 4.0 2.3 E < 2.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 2.5 E < 2.7 4.0 4.0 4.0 4.0 4.0 4.0 4.0 2.7 E < 2.9 4.0 4.0 4.0 4.0 4.0 4.0 4.0 2.9 E < 3.1 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.1 E < 3.3 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.3 E < 3.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.5 E < 3.7 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.7 E < 3.9 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.9 E < 4.1 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.1 E < 4.3 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.3 E < 4.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.5 E < 4.7 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.7 E < 4.9 4.0 4.0 4.0 4.0 4.0 4.0 4.0 E 4.9 4.0 4.0 4.0 4.0 4.0 4.0 4.0 Initial Assembly Avg. Enrichment wt % 235U (E) 32.5 < Assembly Average Burnup 35 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 4.0 4.0 4.0 4.1 4.0 4.1 4.1 2.5 E < 2.7 4.0 4.0 4.0 4.1 4.0 4.0 4.0 2.7 E < 2.9 4.0 4.0 4.0 4.0 4.0 4.0 4.0 2.9 E < 3.1 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.1 E < 3.3 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.3 E < 3.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.5 E < 3.7 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.7 E < 3.9 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.9 E < 4.1 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.1 E < 4.3 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.3 E < 4.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.5 E < 4.7 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.7 E < 4.9 4.0 4.0 4.0 4.0 4.0 4.0 4.0 E 4.9 4.0 4.0 4.0 4.0 4.0 4.0 4.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-36 Amendment No. 9 Table B2-17 Loading Table for PWR Fuel - 1,200 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 35 < Assembly Average Burnup 37.5 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 4.0 4.0 4.3 4.4 4.2 4.4 4.4 2.5 E < 2.7 4.0 4.0 4.3 4.4 4.1 4.4 4.4 2.7 E < 2.9 4.0 4.0 4.2 4.3 4.1 4.3 4.3 2.9 E < 3.1 4.0 4.0 4.2 4.3 4.0 4.3 4.3 3.1 E < 3.3 4.0 4.0 4.1 4.2 4.0 4.2 4.2 3.3 E < 3.5 4.0 4.0 4.1 4.2 4.0 4.2 4.2 3.5 E < 3.7 4.0 4.0 4.0 4.2 4.0 4.2 4.2 3.7 E < 3.9 4.0 4.0 4.0 4.1 4.0 4.1 4.1 3.9 E < 4.1 4.0 4.0 4.0 4.1 4.0 4.1 4.1 4.1 E < 4.3 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.3 E < 4.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.5 E < 4.7 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.7 E < 4.9 4.0 4.0 4.0 4.0 4.0 4.0 4.0 E 4.9 4.0 4.0 4.0 4.0 4.0 4.0 4.0 Initial Assembly Avg. Enrichment wt % 235U (E) 37.5 < Assembly Average Burnup 40 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 4.0 4.1 4.6 4.8 4.4 4.7 4.7 2.7 E < 2.9 4.0 4.0 4.6 4.7 4.4 4.7 4.7 2.9 E < 3.1 4.0 4.0 4.5 4.6 4.3 4.6 4.6 3.1 E < 3.3 4.0 4.0 4.5 4.6 4.3 4.5 4.5 3.3 E < 3.5 4.0 4.0 4.4 4.5 4.2 4.5 4.5 3.5 E < 3.7 4.0 4.0 4.4 4.5 4.2 4.5 4.4 3.7 E < 3.9 4.0 4.0 4.3 4.4 4.1 4.4 4.4 3.9 E < 4.1 4.0 4.0 4.3 4.4 4.1 4.4 4.4 4.1 E < 4.3 4.0 4.0 4.2 4.3 4.1 4.3 4.3 4.3 E < 4.5 4.0 4.0 4.2 4.3 4.0 4.3 4.3 4.5 E < 4.7 4.0 4.0 4.2 4.3 4.0 4.3 4.3 4.7 E < 4.9 4.0 4.0 4.1 4.3 4.0 4.3 4.3 E 4.9 4.0 4.0 4.1 4.2 4.0 4.2 4.2
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-37 Amendment No. 9 Table B2-17 Loading Table for PWR Fuel - 1,200 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 40 < Assembly Average Burnup 41 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 4.2 4.2 4.8 4.9 4.5 4.9 4.9 2.7 E < 2.9 4.1 4.2 4.7 4.8 4.5 4.8 4.8 2.9 E < 3.1 4.0 4.1 4.7 4.8 4.4 4.8 4.7 3.1 E < 3.3 4.0 4.1 4.6 4.7 4.4 4.7 4.7 3.3 E < 3.5 4.0 4.0 4.5 4.7 4.4 4.6 4.6 3.5 E < 3.7 4.0 4.0 4.5 4.6 4.3 4.6 4.6 3.7 E < 3.9 4.0 4.0 4.4 4.5 4.2 4.5 4.5 3.9 E < 4.1 4.0 4.0 4.4 4.5 4.2 4.5 4.5 4.1 E < 4.3 4.0 4.0 4.4 4.5 4.2 4.5 4.5 4.3 E < 4.5 4.0 4.0 4.3 4.4 4.1 4.4 4.4 4.5 E < 4.7 4.0 4.0 4.3 4.4 4.1 4.4 4.4 4.7 E < 4.9 4.0 4.0 4.3 4.4 4.1 4.4 4.4 E 4.9 4.0 4.0 4.2 4.3 4.0 4.4 4.3 Initial Assembly Avg. Enrichment wt % 235U (E) 41 < Assembly Average Burnup 42 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 4.3 4.4 4.9 5.1 4.7 5.0 5.0 2.7 E < 2.9 4.2 4.3 4.9 5.0 4.6 5.0 5.0 2.9 E < 3.1 4.2 4.2 4.8 4.9 4.6 4.9 4.9 3.1 E < 3.3 4.1 4.2 4.7 4.9 4.5 4.8 4.8 3.3 E < 3.5 4.0 4.1 4.7 4.8 4.5 4.8 4.8 3.5 E < 3.7 4.0 4.1 4.6 4.8 4.4 4.7 4.7 3.7 E < 3.9 4.0 4.1 4.6 4.7 4.4 4.7 4.7 3.9 E < 4.1 4.0 4.0 4.5 4.6 4.3 4.6 4.6 4.1 E < 4.3 4.0 4.0 4.5 4.6 4.3 4.6 4.6 4.3 E < 4.5 4.0 4.0 4.4 4.6 4.3 4.5 4.5 4.5 E < 4.7 4.0 4.0 4.4 4.5 4.2 4.5 4.5 4.7 E < 4.9 4.0 4.0 4.4 4.5 4.2 4.5 4.5 E 4.9 4.0 4.0 4.3 4.5 4.2 4.5 4.5
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-38 Amendment No. 9 Table B2-17 Loading Table for PWR Fuel - 1,200 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 42 < Assembly Average Burnup 43 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 4.4 4.5 5.1 5.3 4.9 5.2 5.2 2.7 E < 2.9 4.4 4.4 5.0 5.2 4.8 5.1 5.1 2.9 E < 3.1 4.3 4.4 5.0 5.1 4.7 5.0 5.0 3.1 E < 3.3 4.2 4.3 4.9 5.0 4.7 5.0 5.0 3.3 E < 3.5 4.2 4.3 4.8 5.0 4.6 4.9 4.9 3.5 E < 3.7 4.1 4.2 4.8 4.9 4.5 4.9 4.9 3.7 E < 3.9 4.1 4.2 4.7 4.9 4.5 4.8 4.8 3.9 E < 4.1 4.0 4.1 4.7 4.8 4.4 4.8 4.8 4.1 E < 4.3 4.0 4.1 4.6 4.8 4.4 4.7 4.7 4.3 E < 4.5 4.0 4.0 4.6 4.7 4.4 4.7 4.7 4.5 E < 4.7 4.0 4.0 4.5 4.7 4.3 4.7 4.6 4.7 E < 4.9 4.0 4.0 4.5 4.6 4.3 4.6 4.6 E 4.9 4.0 4.0 4.4 4.6 4.3 4.6 4.5 Initial Assembly Avg. Enrichment wt % 235U (E) 43 < Assembly Average Burnup 44 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 4.5 4.6 5.3 5.5 5.0 5.4 5.4 2.7 E < 2.9 4.5 4.6 5.2 5.4 4.9 5.3 5.3 2.9 E < 3.1 4.4 4.5 5.1 5.3 4.9 5.2 5.2 3.1 E < 3.3 4.4 4.4 5.0 5.2 4.8 5.2 5.2 3.3 E < 3.5 4.3 4.4 5.0 5.1 4.7 5.1 5.1 3.5 E < 3.7 4.2 4.3 4.9 5.1 4.7 5.0 5.0 3.7 E < 3.9 4.2 4.3 4.9 5.0 4.6 5.0 5.0 3.9 E < 4.1 4.1 4.3 4.8 5.0 4.6 4.9 4.9 4.1 E < 4.3 4.1 4.2 4.8 4.9 4.5 4.9 4.9 4.3 E < 4.5 4.1 4.2 4.7 4.9 4.5 4.8 4.8 4.5 E < 4.7 4.0 4.2 4.7 4.8 4.5 4.8 4.8 4.7 E < 4.9 4.0 4.1 4.6 4.8 4.4 4.8 4.7 E 4.9 4.0 4.1 4.6 4.8 4.4 4.7 4.7
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-39 Amendment No. 9 Table B2-17 Loading Table for PWR Fuel - 1,200 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 44 < Assembly Average Burnup 45 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 4.6 4.7 5.4 5.6 5.1 5.5 5.5 2.9 E < 3.1 4.5 4.6 5.3 5.5 5.0 5.4 5.4 3.1 E < 3.3 4.5 4.6 5.2 5.4 4.9 5.4 5.4 3.3 E < 3.5 4.4 4.5 5.2 5.4 4.9 5.3 5.3 3.5 E < 3.7 4.4 4.5 5.1 5.3 4.8 5.2 5.2 3.7 E < 3.9 4.3 4.4 5.0 5.2 4.8 5.1 5.1 3.9 E < 4.1 4.3 4.4 5.0 5.1 4.7 5.1 5.1 4.1 E < 4.3 4.2 4.3 4.9 5.1 4.7 5.0 5.0 4.3 E < 4.5 4.2 4.3 4.9 5.0 4.6 5.0 5.0 4.5 E < 4.7 4.1 4.2 4.8 5.0 4.6 4.9 4.9 4.7 E < 4.9 4.1 4.2 4.8 4.9 4.5 4.9 4.9 E 4.9 4.0 4.2 4.7 4.9 4.5 4.9 4.8
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-40 Amendment No. 9 Note: For fuel assembly average burnup greater than 45 GWd/MTU, cool time tables have been revised to account for a 5% margin in heat load.
Table B2-18 Loading Table for PWR Fuel - 1,140 W/Assembly Initial Assembly Avg. Enrichment wt % 235U (E) 45 < Assembly Average Burnup 46 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 5.0 5.2 6.0 6.2 5.6 6.0 6.0 2.9 E < 3.1 5.0 5.1 5.9 6.0 5.5 6.0 6.0 3.1 E < 3.3 4.9 5.0 5.8 6.0 5.5 5.9 5.9 3.3 E < 3.5 4.8 4.9 5.7 5.9 5.4 5.8 5.8 3.5 E < 3.7 4.8 4.9 5.6 5.8 5.3 5.7 5.7 3.7 E < 3.9 4.7 4.8 5.6 5.8 5.2 5.7 5.7 3.9 E < 4.1 4.6 4.8 5.5 5.7 5.1 5.6 5.6 4.1 E < 4.3 4.6 4.7 5.4 5.6 5.1 5.5 5.6 4.3 E < 4.5 4.5 4.6 5.4 5.6 5.0 5.5 5.5 4.5 E < 4.7 4.5 4.6 5.3 5.5 5.0 5.4 5.4 4.7 E < 4.9 4.4 4.6 5.3 5.5 4.9 5.4 5.4 E 4.9 4.4 4.5 5.2 5.4 4.9 5.4 5.3
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-41 Amendment No. 9 Table B2-18 Loading Table for PWR Fuel - 1,140 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 46 < Assembly Average Burnup 47 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 5.2 5.4 6.2 6.5 5.8 6.3 6.3 2.9 E < 3.1 5.1 5.3 6.1 6.4 5.7 6.2 6.2 3.1 E < 3.3 5.0 5.2 6.0 6.2 5.6 6.1 6.1 3.3 E < 3.5 5.0 5.1 5.9 6.1 5.6 6.0 6.0 3.5 E < 3.7 4.9 5.0 5.8 6.0 5.5 5.9 5.9 3.7 E < 3.9 4.8 5.0 5.8 6.0 5.4 5.9 5.9 3.9 E < 4.1 4.8 4.9 5.7 5.9 5.3 5.8 5.8 4.1 E < 4.3 4.7 4.8 5.6 5.8 5.3 5.8 5.7 4.3 E < 4.5 4.7 4.8 5.6 5.8 5.2 5.7 5.7 4.5 E < 4.7 4.6 4.7 5.5 5.7 5.2 5.6 5.6 4.7 E < 4.9 4.6 4.7 5.5 5.7 5.1 5.6 5.6 E 4.9 4.5 4.7 5.4 5.6 5.0 5.5 5.5 Initial Assembly Avg. Enrichment wt % 235U (E) 47 < Assembly Average Burnup 48 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 5.4 5.6 6.5 6.8 6.0 6.6 6.6 2.9 E < 3.1 5.3 5.5 6.4 6.6 5.9 6.5 6.5 3.1 E < 3.3 5.2 5.4 6.2 6.5 5.8 6.4 6.4 3.3 E < 3.5 5.1 5.3 6.1 6.4 5.8 6.2 6.2 3.5 E < 3.7 5.0 5.2 6.0 6.3 5.7 6.2 6.1 3.7 E < 3.9 5.0 5.1 5.9 6.2 5.6 6.0 6.0 3.9 E < 4.1 4.9 5.0 5.9 6.1 5.5 6.0 6.0 4.1 E < 4.3 4.9 5.0 5.8 6.0 5.5 5.9 5.9 4.3 E < 4.5 4.8 4.9 5.8 6.0 5.4 5.9 5.9 4.5 E < 4.7 4.8 4.9 5.7 5.9 5.3 5.8 5.8 4.7 E < 4.9 4.7 4.9 5.7 5.8 5.3 5.8 5.8 E 4.9 4.7 4.8 5.6 5.8 5.2 5.7 5.7
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-42 Amendment No. 9 Table B2-18 Loading Table for PWR Fuel - 1,140 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 48 < Assembly Average Burnup 49 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 5.6 5.8 6.8 7.0 6.3 6.9 6.9 2.9 E < 3.1 5.5 5.7 6.7 6.9 6.1 6.8 6.7 3.1 E < 3.3 5.4 5.6 6.5 6.8 6.0 6.6 6.6 3.3 E < 3.5 5.3 5.5 6.4 6.7 5.9 6.5 6.5 3.5 E < 3.7 5.2 5.4 6.3 6.6 5.9 6.4 6.4 3.7 E < 3.9 5.2 5.3 6.2 6.5 5.8 6.3 6.3 3.9 E < 4.1 5.1 5.2 6.1 6.4 5.7 6.2 6.2 4.1 E < 4.3 5.0 5.2 6.0 6.3 5.7 6.1 6.1 4.3 E < 4.5 5.0 5.1 5.9 6.2 5.6 6.0 6.0 4.5 E < 4.7 4.9 5.0 5.9 6.1 5.5 6.0 6.0 4.7 E < 4.9 4.8 5.0 5.8 6.0 5.5 5.9 5.9 E 4.9 4.8 4.9 5.8 6.0 5.4 5.9 5.9 Initial Assembly Avg. Enrichment wt % 235U (E) 49 < Assembly Average Burnup 50 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 5.7 5.8 6.9 7.3 6.4 7.0 7.0 3.1 E < 3.3 5.6 5.7 6.8 7.1 6.3 6.9 6.9 3.3 E < 3.5 5.5 5.6 6.7 7.0 6.2 6.8 6.8 3.5 E < 3.7 5.4 5.5 6.6 6.9 6.0 6.7 6.7 3.7 E < 3.9 5.4 5.5 6.5 6.8 6.0 6.6 6.6 3.9 E < 4.1 5.3 5.4 6.4 6.7 5.9 6.5 6.5 4.1 E < 4.3 5.2 5.3 6.3 6.6 5.8 6.4 6.4 4.3 E < 4.5 5.1 5.2 6.2 6.5 5.8 6.3 6.3 4.5 E < 4.7 5.0 5.2 6.1 6.4 5.7 6.2 6.2 4.7 E < 4.9 5.0 5.1 6.0 6.3 5.7 6.2 6.2 E 4.9 4.9 5.0 6.0 6.2 5.6 6.1 6.1
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-43 Amendment No. 9 Table B2-18 Loading Table for PWR Fuel - 1,140 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 50 < Assembly Average Burnup 51 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 5.8 6.0 7.3 7.6 6.7 7.4 7.4 3.1 E < 3.3 5.8 5.9 7.1 7.5 6.6 7.2 7.2 3.3 E < 3.5 5.7 5.8 7.0 7.3 6.4 7.1 7.0 3.5 E < 3.7 5.6 5.7 6.8 7.2 6.3 6.9 6.9 3.7 E < 3.9 5.5 5.7 6.7 7.0 6.2 6.9 6.8 3.9 E < 4.1 5.4 5.6 6.6 6.9 6.1 6.8 6.8 4.1 E < 4.3 5.3 5.5 6.5 6.8 6.0 6.7 6.7 4.3 E < 4.5 5.2 5.4 6.4 6.8 6.0 6.6 6.6 4.5 E < 4.7 5.2 5.4 6.4 6.7 5.9 6.5 6.5 4.7 E < 4.9 5.1 5.3 6.3 6.6 5.8 6.4 6.4 E 4.9 5.0 5.2 6.2 6.5 5.8 6.4 6.3 Initial Assembly Avg. Enrichment wt % 235U (E) 51 < Assembly Average Burnup 52 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 6.0 6.3 7.6 7.9 6.9 7.7 7.7 3.1 E < 3.3 5.9 6.1 7.5 7.7 6.8 7.6 7.6 3.3 E < 3.5 5.8 6.0 7.3 7.6 6.7 7.4 7.4 3.5 E < 3.7 5.8 5.9 7.1 7.4 6.6 7.3 7.3 3.7 E < 3.9 5.7 5.9 7.0 7.3 6.5 7.1 7.1 3.9 E < 4.1 5.6 5.8 6.9 7.1 6.4 7.0 7.0 4.1 E < 4.3 5.5 5.7 6.8 7.0 6.3 6.9 6.9 4.3 E < 4.5 5.4 5.6 6.7 6.9 6.2 6.8 6.8 4.5 E < 4.7 5.4 5.6 6.6 6.8 6.1 6.8 6.8 4.7 E < 4.9 5.3 5.5 6.5 6.8 6.0 6.7 6.7 E 4.9 5.2 5.4 6.5 6.7 6.0 6.6 6.6
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-44 Amendment No. 9 Table B2-18 Loading Table for PWR Fuel - 1,140 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 52 < Assembly Average Burnup 53 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 6.3 6.5 7.9 8.3 7.3 8.1 8.1 3.1 E < 3.3 6.2 6.4 7.7 8.1 7.1 7.9 7.9 3.3 E < 3.5 6.0 6.3 7.5 7.9 7.0 7.8 7.8 3.5 E < 3.7 5.9 6.1 7.4 7.8 6.9 7.6 7.6 3.7 E < 3.9 5.8 6.1 7.2 7.6 6.7 7.5 7.5 3.9 E < 4.1 5.8 6.0 7.1 7.5 6.6 7.4 7.3 4.1 E < 4.3 5.7 5.9 7.0 7.4 6.5 7.2 7.2 4.3 E < 4.5 5.6 5.8 6.9 7.2 6.4 7.1 7.1 4.5 E < 4.7 5.5 5.7 6.8 7.1 6.4 7.0 7.0 4.7 E < 4.9 5.5 5.7 6.7 7.0 6.3 6.9 6.9 E 4.9 5.4 5.6 6.6 6.9 6.2 6.9 6.9 Initial Assembly Avg. Enrichment wt % 235U (E) 53 < Assembly Average Burnup 54 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 6.6 6.8 8.3 8.8 7.6 8.6 8.6 3.1 E < 3.3 6.4 6.7 8.0 8.6 7.5 8.3 8.3 3.3 E < 3.5 6.3 6.5 7.9 8.3 7.3 8.2 8.1 3.5 E < 3.7 6.1 6.4 7.7 8.1 7.1 8.0 8.0 3.7 E < 3.9 6.0 6.3 7.6 8.0 7.0 7.9 7.8 3.9 E < 4.1 5.9 6.2 7.4 7.8 6.9 7.7 7.7 4.1 E < 4.3 5.9 6.1 7.3 7.7 6.8 7.6 7.6 4.3 E < 4.5 5.8 6.0 7.2 7.6 6.7 7.5 7.5 4.5 E < 4.7 5.7 5.9 7.0 7.5 6.6 7.4 7.3 4.7 E < 4.9 5.7 5.9 7.0 7.4 6.5 7.2 7.2 E 4.9 5.6 5.9 6.9 7.3 6.4 7.1 7.1
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-45 Amendment No. 9 Table B2-18 Loading Table for PWR Fuel - 1,140 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 54 < Assembly Average Burnup 55 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 6.7 6.9 8.5 9.0 7.8 8.8 8.8 3.3 E < 3.5 6.6 6.8 8.3 8.8 7.6 8.6 8.6 3.5 E < 3.7 6.4 6.7 8.1 8.6 7.5 8.4 8.4 3.7 E < 3.9 6.3 6.6 7.9 8.4 7.3 8.2 8.2 3.9 E < 4.1 6.2 6.5 7.8 8.2 7.2 8.0 8.0 4.1 E < 4.3 6.1 6.3 7.6 8.1 7.0 7.9 7.9 4.3 E < 4.5 6.0 6.2 7.5 7.9 7.0 7.8 7.8 4.5 E < 4.7 5.9 6.1 7.4 7.8 6.9 7.7 7.7 4.7 E < 4.9 5.9 6.0 7.3 7.7 6.8 7.6 7.6 E 4.9 5.8 6.0 7.2 7.6 6.7 7.5 7.5 Initial Assembly Avg. Enrichment wt % 235U (E) 55 < Assembly Average Burnup 56 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 6.9 7.3 8.9 9.6 8.0 9.3 9.3 3.3 E < 3.5 6.8 7.1 8.7 9.3 7.8 9.0 9.0 3.5 E < 3.7 6.7 6.9 8.5 9.1 7.7 8.8 8.9 3.7 E < 3.9 6.6 6.8 8.3 8.9 7.5 8.7 8.7 3.9 E < 4.1 6.4 6.7 8.1 8.7 7.4 8.5 8.5 4.1 E < 4.3 6.3 6.6 8.0 8.5 7.2 8.3 8.3 4.3 E < 4.5 6.2 6.5 7.9 8.4 7.1 8.2 8.1 4.5 E < 4.7 6.1 6.4 7.7 8.2 7.0 8.0 8.0 4.7 E < 4.9 6.0 6.3 7.6 8.1 6.9 7.9 7.9 E 4.9 6.0 6.2 7.5 8.0 6.8 7.8 7.8
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-46 Amendment No. 9 Table B2-18 Loading Table for PWR Fuel - 1,140 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 56 < Assembly Average Burnup 57 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 7.3 7.6 9.4 10.1 8.4 9.8 9.8 3.3 E < 3.5 7.1 7.4 9.2 9.9 8.2 9.6 9.6 3.5 E < 3.7 6.9 7.3 9.0 9.6 8.0 9.4 9.3 3.7 E < 3.9 6.8 7.1 8.8 9.4 7.9 9.1 9.1 3.9 E < 4.1 6.7 7.0 8.6 9.2 7.7 8.9 8.9 4.1 E < 4.3 6.6 6.9 8.4 9.0 7.6 8.8 8.8 4.3 E < 4.5 6.5 6.8 8.2 8.8 7.5 8.6 8.6 4.5 E < 4.7 6.4 6.7 8.1 8.7 7.3 8.5 8.4 4.7 E < 4.9 6.3 6.6 8.0 8.5 7.2 8.3 8.3 E 4.9 6.2 6.5 7.8 8.4 7.1 8.2 8.2 Initial Assembly Avg. Enrichment wt % 235U (E) 57 < Assembly Average Burnup 58 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 7.6 8.0 10.0 10.8 8.9 10.5 10.4 3.3 E < 3.5 7.4 7.8 9.7 10.5 8.7 10.2 10.1 3.5 E < 3.7 7.2 7.6 9.5 10.2 8.4 9.9 9.9 3.7 E < 3.9 7.1 7.5 9.3 9.9 8.2 9.7 9.6 3.9 E < 4.1 6.9 7.3 9.0 9.7 8.1 9.5 9.4 4.1 E < 4.3 6.8 7.1 8.8 9.5 7.9 9.2 9.2 4.3 E < 4.5 6.7 7.0 8.7 9.3 7.8 9.0 9.0 4.5 E < 4.7 6.6 6.9 8.5 9.1 7.7 8.9 8.9 4.7 E < 4.9 6.5 6.8 8.4 8.9 7.5 8.7 8.7 E 4.9 6.4 6.7 8.2 8.8 7.4 8.6 8.6
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-47 Amendment No. 9 Table B2-18 Loading Table for PWR Fuel - 1,140 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 58 < Assembly Average Burnup 59 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 7.9 8.4 10.7 11.5 9.4 11.1 11.1 3.3 E < 3.5 7.8 8.2 10.3 11.2 9.1 10.8 10.8 3.5 E < 3.7 7.6 8.0 10.0 10.9 8.9 10.5 10.5 3.7 E < 3.9 7.4 7.8 9.8 10.6 8.7 10.2 10.2 3.9 E < 4.1 7.2 7.6 9.5 10.3 8.5 10.0 9.9 4.1 E < 4.3 7.1 7.5 9.3 10.0 8.3 9.8 9.7 4.3 E < 4.5 7.0 7.3 9.1 9.8 8.1 9.6 9.5 4.5 E < 4.7 6.9 7.2 8.9 9.6 8.0 9.4 9.4 4.7 E < 4.9 6.8 7.1 8.8 9.5 7.9 9.2 9.2 E 4.9 6.7 7.0 8.7 9.3 7.8 9.0 9.0 Initial Assembly Avg. Enrichment wt % 235U (E) 59 < Assembly Average Burnup 60 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 3.3 E < 3.5 8.1 8.6 11.0 11.8 9.6 11.2 11.2 3.5 E < 3.7 7.9 8.4 10.7 11.5 9.4 10.9 10.8 3.7 E < 3.9 7.7 8.2 10.3 11.2 9.1 10.6 10.5 3.9 E < 4.1 7.6 8.0 10.1 11.0 8.9 10.3 10.3 4.1 E < 4.3 7.4 7.8 9.8 10.7 8.7 10.0 10.0 4.3 E < 4.5 7.3 7.7 9.6 10.4 8.5 9.8 9.8 4.5 E < 4.7 7.1 7.6 9.4 10.2 8.4 9.7 9.6 4.7 E < 4.9 7.0 7.4 9.2 10.0 8.2 9.5 9.4 E 4.9 6.9 7.3 9.1 9.8 8.1 9.3 9.3
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-48 Amendment No. 9 Table B2-19 Loading Table for PWR Fuel - 922 W/Assembly Initial Assembly Avg. Enrichment wt % 235U (E) 30 < Assembly Average Burnup 32.5 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 4.2 4.3 4.8 4.9 4.6 4.9 4.9 2.3 E < 2.5 4.2 4.2 4.7 4.8 4.5 4.8 4.8 2.5 E < 2.7 4.1 4.2 4.7 4.8 4.5 4.8 4.8 2.7 E < 2.9 4.1 4.1 4.6 4.7 4.4 4.7 4.7 2.9 E < 3.1 4.0 4.1 4.6 4.7 4.4 4.7 4.7 3.1 E < 3.3 4.0 4.0 4.5 4.6 4.3 4.6 4.6 3.3 E < 3.5 4.0 4.0 4.5 4.6 4.3 4.6 4.6 3.5 E < 3.7 4.0 4.0 4.5 4.5 4.3 4.5 4.5 3.7 E < 3.9 4.0 4.0 4.4 4.5 4.2 4.5 4.5 3.9 E < 4.1 4.0 4.0 4.4 4.5 4.2 4.5 4.5 4.1 E < 4.3 4.0 4.0 4.4 4.5 4.2 4.4 4.4 4.3 E < 4.5 4.0 4.0 4.3 4.4 4.2 4.4 4.4 4.5 E < 4.7 4.0 4.0 4.3 4.4 4.1 4.4 4.4 4.7 E < 4.9 4.0 4.0 4.3 4.4 4.1 4.4 4.4 E 4.9 4.0 4.0 4.3 4.4 4.1 4.4 4.4 Initial Assembly Avg. Enrichment wt % 235U (E) 32.5 < Assembly Average Burnup 35 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 4.5 4.6 5.2 5.3 4.9 5.3 5.3 2.5 E < 2.7 4.4 4.5 5.1 5.3 4.9 5.2 5.2 2.7 E < 2.9 4.4 4.5 5.0 5.2 4.8 5.1 5.1 2.9 E < 3.1 4.4 4.4 5.0 5.1 4.8 5.1 5.1 3.1 E < 3.3 4.3 4.4 4.9 5.0 4.7 5.0 5.0 3.3 E < 3.5 4.3 4.3 4.9 5.0 4.7 5.0 5.0 3.5 E < 3.7 4.2 4.3 4.8 5.0 4.6 4.9 4.9 3.7 E < 3.9 4.2 4.3 4.8 4.9 4.6 4.9 4.9 3.9 E < 4.1 4.1 4.2 4.8 4.9 4.5 4.9 4.9 4.1 E < 4.3 4.1 4.2 4.7 4.9 4.5 4.8 4.8 4.3 E < 4.5 4.1 4.2 4.7 4.8 4.5 4.8 4.8 4.5 E < 4.7 4.0 4.1 4.7 4.8 4.5 4.8 4.8 4.7 E < 4.9 4.0 4.1 4.6 4.8 4.4 4.7 4.7 E 4.9 4.0 4.1 4.6 4.7 4.4 4.7 4.7
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-49 Amendment No. 9 Table B2-19 Loading Table for PWR Fuel - 922 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 35 < Assembly Average Burnup 37.5 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 4.9 5.0 5.7 5.9 5.4 5.8 5.8 2.5 E < 2.7 4.8 4.9 5.7 5.8 5.3 5.7 5.7 2.7 E < 2.9 4.8 4.9 5.6 5.8 5.3 5.7 5.7 2.9 E < 3.1 4.7 4.8 5.5 5.7 5.2 5.6 5.6 3.1 E < 3.3 4.6 4.7 5.4 5.6 5.1 5.5 5.5 3.3 E < 3.5 4.6 4.7 5.4 5.6 5.0 5.5 5.5 3.5 E < 3.7 4.5 4.6 5.3 5.5 5.0 5.4 5.4 3.7 E < 3.9 4.5 4.6 5.3 5.4 5.0 5.4 5.4 3.9 E < 4.1 4.5 4.6 5.2 5.4 4.9 5.3 5.3 4.1 E < 4.3 4.4 4.5 5.2 5.4 4.9 5.3 5.3 4.3 E < 4.5 4.4 4.5 5.1 5.3 4.9 5.2 5.2 4.5 E < 4.7 4.4 4.5 5.1 5.3 4.8 5.2 5.2 4.7 E < 4.9 4.3 4.4 5.0 5.2 4.8 5.2 5.2 E 4.9 4.3 4.4 5.0 5.2 4.8 5.1 5.1 Initial Assembly Avg. Enrichment wt % 235U (E) 37.5 < Assembly Average Burnup 40 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 5.3 5.4 6.2 6.5 5.9 6.3 6.3 2.7 E < 2.9 5.2 5.3 6.1 6.4 5.8 6.2 6.2 2.9 E < 3.1 5.1 5.3 6.0 6.3 5.7 6.1 6.1 3.1 E < 3.3 5.0 5.2 6.0 6.2 5.6 6.0 6.0 3.3 E < 3.5 5.0 5.1 5.9 6.1 5.6 6.0 6.0 3.5 E < 3.7 4.9 5.0 5.9 6.0 5.5 5.9 5.9 3.7 E < 3.9 4.9 5.0 5.8 6.0 5.5 5.9 5.9 3.9 E < 4.1 4.8 5.0 5.7 5.9 5.4 5.8 5.8 4.1 E < 4.3 4.8 4.9 5.7 5.9 5.4 5.8 5.8 4.3 E < 4.5 4.8 4.9 5.7 5.8 5.3 5.8 5.7 4.5 E < 4.7 4.7 4.8 5.6 5.8 5.3 5.7 5.7 4.7 E < 4.9 4.7 4.8 5.6 5.8 5.2 5.7 5.7 E 4.9 4.6 4.8 5.5 5.7 5.2 5.6 5.6
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-50 Amendment No. 9 Table B2-19 Loading Table for PWR Fuel - 922 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 40 < Assembly Average Burnup 41 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 5.5 5.6 6.6 6.8 6.0 6.6 6.6 2.7 E < 2.9 5.4 5.6 6.4 6.7 6.0 6.5 6.5 2.9 E < 3.1 5.3 5.5 6.3 6.6 5.9 6.4 6.4 3.1 E < 3.3 5.3 5.4 6.2 6.5 5.8 6.3 6.3 3.3 E < 3.5 5.2 5.3 6.1 6.4 5.8 6.3 6.2 3.5 E < 3.7 5.1 5.3 6.1 6.3 5.7 6.2 6.2 3.7 E < 3.9 5.0 5.2 6.0 6.2 5.7 6.1 6.1 3.9 E < 4.1 5.0 5.1 5.9 6.2 5.6 6.0 6.0 4.1 E < 4.3 5.0 5.1 5.9 6.1 5.6 6.0 6.0 4.3 E < 4.5 4.9 5.0 5.9 6.0 5.5 5.9 5.9 4.5 E < 4.7 4.9 5.0 5.8 6.0 5.5 5.9 5.9 4.7 E < 4.9 4.8 5.0 5.8 6.0 5.4 5.9 5.9 E 4.9 4.8 4.9 5.7 5.9 5.4 5.8 5.8 Initial Assembly Avg. Enrichment wt % 235U (E) 41 < Assembly Average Burnup 42 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 5.7 5.9 6.9 7.1 6.4 6.9 6.9 2.7 E < 2.9 5.6 5.8 6.7 7.0 6.2 6.8 6.8 2.9 E < 3.1 5.6 5.7 6.6 6.9 6.1 6.7 6.7 3.1 E < 3.3 5.5 5.6 6.5 6.8 6.0 6.6 6.6 3.3 E < 3.5 5.4 5.5 6.4 6.7 6.0 6.6 6.5 3.5 E < 3.7 5.3 5.5 6.4 6.6 5.9 6.5 6.5 3.7 E < 3.9 5.3 5.4 6.3 6.6 5.9 6.4 6.4 3.9 E < 4.1 5.2 5.4 6.2 6.5 5.8 6.3 6.3 4.1 E < 4.3 5.1 5.3 6.1 6.4 5.8 6.3 6.2 4.3 E < 4.5 5.1 5.2 6.0 6.3 5.7 6.2 6.2 4.5 E < 4.7 5.0 5.2 6.0 6.3 5.7 6.1 6.1 4.7 E < 4.9 5.0 5.1 6.0 6.2 5.6 6.1 6.1 E 4.9 4.9 5.1 5.9 6.2 5.6 6.0 6.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-51 Amendment No. 9 Table B2-19 Loading Table for PWR Fuel - 922 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 42 < Assembly Average Burnup 43 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 5.9 6.1 7.2 7.5 6.7 7.3 7.3 2.7 E < 2.9 5.8 6.0 7.0 7.4 6.5 7.1 7.1 2.9 E < 3.1 5.8 5.9 6.9 7.3 6.4 7.0 7.0 3.1 E < 3.3 5.7 5.8 6.8 7.1 6.3 6.9 6.9 3.3 E < 3.5 5.6 5.8 6.7 7.0 6.2 6.8 6.8 3.5 E < 3.7 5.5 5.7 6.7 6.9 6.1 6.8 6.7 3.7 E < 3.9 5.5 5.6 6.6 6.8 6.1 6.7 6.7 3.9 E < 4.1 5.4 5.6 6.5 6.8 6.0 6.6 6.6 4.1 E < 4.3 5.3 5.5 6.4 6.7 6.0 6.5 6.5 4.3 E < 4.5 5.3 5.5 6.4 6.6 5.9 6.5 6.5 4.5 E < 4.7 5.2 5.4 6.3 6.6 5.9 6.4 6.4 4.7 E < 4.9 5.2 5.3 6.2 6.5 5.8 6.4 6.4 E 4.9 5.1 5.3 6.2 6.5 5.8 6.3 6.3 Initial Assembly Avg. Enrichment wt % 235U (E) 43 < Assembly Average Burnup 44 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 6.2 6.4 7.6 8.0 6.9 7.7 7.7 2.7 E < 2.9 6.0 6.2 7.4 7.8 6.8 7.5 7.5 2.9 E < 3.1 6.0 6.1 7.3 7.7 6.7 7.4 7.4 3.1 E < 3.3 5.9 6.0 7.2 7.5 6.6 7.3 7.3 3.3 E < 3.5 5.8 6.0 7.0 7.4 6.5 7.1 7.1 3.5 E < 3.7 5.8 5.9 6.9 7.3 6.4 7.0 7.0 3.7 E < 3.9 5.7 5.8 6.9 7.2 6.3 7.0 7.0 3.9 E < 4.1 5.6 5.8 6.8 7.1 6.3 6.9 6.9 4.1 E < 4.3 5.5 5.7 6.7 7.0 6.2 6.8 6.8 4.3 E < 4.5 5.5 5.7 6.7 6.9 6.1 6.8 6.8 4.5 E < 4.7 5.4 5.6 6.6 6.9 6.0 6.7 6.7 4.7 E < 4.9 5.4 5.6 6.5 6.8 6.0 6.6 6.6 E 4.9 5.3 5.5 6.5 6.8 6.0 6.6 6.6
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-52 Amendment No. 9 Table B2-19 Loading Table for PWR Fuel - 922 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 44 < Assembly Average Burnup 45 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 6.3 6.6 7.8 8.3 7.1 7.9 7.9 2.9 E < 3.1 6.2 6.4 7.7 8.1 7.0 7.8 7.8 3.1 E < 3.3 6.1 6.3 7.6 7.9 6.9 7.7 7.7 3.3 E < 3.5 6.0 6.2 7.4 7.8 6.8 7.5 7.5 3.5 E < 3.7 5.9 6.1 7.3 7.7 6.7 7.4 7.4 3.7 E < 3.9 5.9 6.0 7.2 7.6 6.6 7.3 7.3 3.9 E < 4.1 5.8 6.0 7.1 7.5 6.6 7.2 7.2 4.1 E < 4.3 5.7 5.9 7.0 7.4 6.5 7.1 7.1 4.3 E < 4.5 5.7 5.9 6.9 7.3 6.4 7.0 7.0 4.5 E < 4.7 5.6 5.8 6.9 7.2 6.3 7.0 7.0 4.7 E < 4.9 5.6 5.8 6.8 7.1 6.3 6.9 6.9 E 4.9 5.5 5.7 6.7 7.0 6.2 6.9 6.9
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-53 Amendment No. 9 Note: For fuel assembly average burnup greater than 45 GWd/MTU, cool time tables have been revised to account for a 5% margin in heat load.
Table B2-20 Loading Table for PWR Fuel - 876 W/Assembly Initial Assembly Avg. Enrichment wt % 235U (E) 45 < Assembly Average Burnup 46 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 7.1 7.4 9.2 9.8 8.2 9.3 9.3 2.9 E < 3.1 7.0 7.3 9.0 9.6 8.0 9.1 9.0 3.1 E < 3.3 6.9 7.1 8.8 9.4 7.9 8.9 8.9 3.3 E < 3.5 6.8 7.0 8.6 9.1 7.8 8.7 8.7 3.5 E < 3.7 6.7 6.9 8.5 9.0 7.6 8.6 8.6 3.7 E < 3.9 6.6 6.8 8.3 8.9 7.5 8.5 8.4 3.9 E < 4.1 6.5 6.7 8.2 8.7 7.4 8.3 8.3 4.1 E < 4.3 6.4 6.6 8.1 8.6 7.3 8.2 8.2 4.3 E < 4.5 6.3 6.6 8.0 8.5 7.2 8.1 8.1 4.5 E < 4.7 6.2 6.5 7.9 8.4 7.2 8.0 8.0 4.7 E < 4.9 6.2 6.4 7.8 8.3 7.1 8.0 7.9 E 4.9 6.1 6.4 7.7 8.2 7.0 7.9 7.9
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-54 Amendment No. 9 Table B2-20 Loading Table for PWR Fuel - 876 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 46 < Assembly Average Burnup 47 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 7.5 7.8 9.8 10.5 8.7 9.9 9.9 2.9 E < 3.1 7.4 7.7 9.6 10.3 8.5 9.7 9.7 3.1 E < 3.3 7.2 7.5 9.3 10.0 8.3 9.5 9.5 3.3 E < 3.5 7.1 7.4 9.1 9.8 8.1 9.3 9.3 3.5 E < 3.7 7.0 7.2 9.0 9.6 8.0 9.1 9.1 3.7 E < 3.9 6.9 7.1 8.8 9.4 7.9 9.0 8.9 3.9 E < 4.1 6.8 7.0 8.7 9.3 7.8 8.8 8.8 4.1 E < 4.3 6.7 6.9 8.6 9.1 7.7 8.7 8.7 4.3 E < 4.5 6.6 6.9 8.4 9.0 7.6 8.6 8.6 4.5 E < 4.7 6.5 6.8 8.3 8.9 7.5 8.5 8.5 4.7 E < 4.9 6.5 6.7 8.2 8.8 7.5 8.4 8.4 E 4.9 6.4 6.7 8.1 8.7 7.4 8.3 8.3 Initial Assembly Avg. Enrichment wt % 235U (E) 47 < Assembly Average Burnup 48 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 7.9 8.3 10.5 11.3 9.2 10.7 10.6 2.9 E < 3.1 7.7 8.1 10.2 11.1 9.0 10.4 10.3 3.1 E < 3.3 7.6 7.9 10.0 10.8 8.8 10.1 10.1 3.3 E < 3.5 7.4 7.8 9.7 10.5 8.7 9.9 9.9 3.5 E < 3.7 7.3 7.6 9.6 10.3 8.5 9.7 9.7 3.7 E < 3.9 7.2 7.5 9.4 10.1 8.4 9.5 9.5 3.9 E < 4.1 7.0 7.4 9.2 9.9 8.2 9.4 9.4 4.1 E < 4.3 7.0 7.3 9.0 9.7 8.1 9.2 9.2 4.3 E < 4.5 6.9 7.2 8.9 9.6 8.0 9.1 9.1 4.5 E < 4.7 6.8 7.1 8.8 9.5 7.9 9.0 9.0 4.7 E < 4.9 6.7 7.0 8.7 9.4 7.8 8.9 8.9 E 4.9 6.7 6.9 8.6 9.2 7.7 8.8 8.8
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-55 Amendment No. 9 Table B2-20 Loading Table for PWR Fuel - 876 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 48 < Assembly Average Burnup 49 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 8.4 8.8 11.3 12.1 9.9 11.4 11.4 2.9 E < 3.1 8.2 8.6 11.0 11.8 9.6 11.1 11.1 3.1 E < 3.3 8.0 8.4 10.7 11.6 9.4 10.9 10.8 3.3 E < 3.5 7.8 8.2 10.4 11.3 9.2 10.6 10.6 3.5 E < 3.7 7.7 8.0 10.2 11.1 9.0 10.4 10.4 3.7 E < 3.9 7.6 7.9 10.0 10.8 8.8 10.2 10.1 3.9 E < 4.1 7.4 7.8 9.8 10.6 8.7 10.0 9.9 4.1 E < 4.3 7.3 7.7 9.7 10.4 8.6 9.8 9.8 4.3 E < 4.5 7.2 7.6 9.5 10.3 8.4 9.7 9.7 4.5 E < 4.7 7.1 7.5 9.4 10.1 8.3 9.6 9.5 4.7 E < 4.9 7.0 7.4 9.2 10.0 8.2 9.4 9.4 E 4.9 6.9 7.3 9.1 9.8 8.1 9.3 9.3 Initial Assembly Avg. Enrichment wt % 235U (E) 49 < Assembly Average Burnup 50 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 8.7 8.9 11.8 12.7 10.2 11.9 11.9 3.1 E < 3.3 8.4 8.7 11.5 12.4 10.0 11.7 11.6 3.3 E < 3.5 8.2 8.5 11.2 12.1 9.8 11.4 11.4 3.5 E < 3.7 8.1 8.4 11.0 11.8 9.6 11.2 11.1 3.7 E < 3.9 7.9 8.2 10.7 11.6 9.4 10.9 10.9 3.9 E < 4.1 7.8 8.0 10.5 11.4 9.2 10.7 10.7 4.1 E < 4.3 7.7 7.9 10.3 11.2 9.0 10.5 10.5 4.3 E < 4.5 7.6 7.8 10.1 11.0 8.9 10.4 10.3 4.5 E < 4.7 7.5 7.7 9.9 10.9 8.8 10.2 10.1 4.7 E < 4.9 7.4 7.6 9.8 10.7 8.7 10.0 10.0 E 4.9 7.3 7.6 9.7 10.5 8.6 9.9 9.9
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-56 Amendment No. 9 Table B2-20 Loading Table for PWR Fuel - 876 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 50 < Assembly Average Burnup 51 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 8.9 9.5 12.6 13.7 11.0 12.8 12.8 3.1 E < 3.3 8.7 9.3 12.2 13.3 10.7 12.5 12.4 3.3 E < 3.5 8.5 9.0 11.9 13.0 10.5 12.1 12.1 3.5 E < 3.7 8.4 8.8 11.7 12.7 10.2 11.9 11.9 3.7 E < 3.9 8.2 8.7 11.5 12.4 10.0 11.7 11.6 3.9 E < 4.1 8.0 8.5 11.2 12.2 9.8 11.5 11.4 4.1 E < 4.3 7.9 8.4 11.0 11.9 9.6 11.3 11.2 4.3 E < 4.5 7.8 8.2 10.9 11.8 9.5 11.1 11.0 4.5 E < 4.7 7.7 8.1 10.7 11.6 9.3 10.9 10.9 4.7 E < 4.9 7.6 8.0 10.5 11.4 9.2 10.8 10.7 E 4.9 7.5 7.9 10.4 11.3 9.1 10.6 10.6 Initial Assembly Avg. Enrichment wt % 235U (E) 51 < Assembly Average Burnup 52 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 9.5 10.1 13.5 14.3 11.7 13.7 13.7 3.1 E < 3.3 9.2 9.8 13.2 13.9 11.5 13.4 13.4 3.3 E < 3.5 9.0 9.6 12.8 13.6 11.2 13.1 13.0 3.5 E < 3.7 8.8 9.4 12.5 13.3 10.9 12.8 12.7 3.7 E < 3.9 8.7 9.2 12.2 13.0 10.7 12.5 12.4 3.9 E < 4.1 8.5 9.0 12.0 12.8 10.4 12.2 12.2 4.1 E < 4.3 8.3 8.9 11.8 12.5 10.2 12.0 11.9 4.3 E < 4.5 8.2 8.7 11.6 12.3 10.0 11.8 11.8 4.5 E < 4.7 8.1 8.6 11.4 12.1 9.9 11.6 11.6 4.7 E < 4.9 8.0 8.5 11.2 11.9 9.8 11.5 11.5 E 4.9 7.9 8.3 11.1 11.8 9.6 11.3 11.3
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-57 Amendment No. 9 Table B2-20 Loading Table for PWR Fuel - 876 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 52 < Assembly Average Burnup 53 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 10.1 10.9 14.0 15.3 12.6 14.7 14.7 3.1 E < 3.3 9.8 10.5 13.7 14.9 12.2 14.3 14.3 3.3 E < 3.5 9.6 10.2 13.4 14.6 11.9 14.0 13.9 3.5 E < 3.7 9.3 10.0 13.1 14.2 11.6 13.7 13.6 3.7 E < 3.9 9.1 9.9 12.8 13.9 11.4 13.4 13.3 3.9 E < 4.1 8.9 9.6 12.5 13.7 11.2 13.1 13.1 4.1 E < 4.3 8.8 9.4 12.2 13.4 11.0 12.9 12.8 4.3 E < 4.5 8.7 9.2 12.0 13.2 10.8 12.6 12.6 4.5 E < 4.7 8.5 9.0 11.8 13.0 10.6 12.4 12.4 4.7 E < 4.9 8.4 8.9 11.7 12.8 10.4 12.2 12.2 E 4.9 8.3 8.8 11.5 12.6 10.2 12.0 12.0 Initial Assembly Avg. Enrichment wt % 235U (E) 53 < Assembly Average Burnup 54 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 10.8 11.6 15.1 16.4 13.5 15.7 15.6 3.1 E < 3.3 10.5 11.3 14.6 15.9 13.1 15.3 15.3 3.3 E < 3.5 10.1 11.0 14.2 15.6 12.7 14.9 14.9 3.5 E < 3.7 9.9 10.7 13.9 15.2 12.4 14.6 14.6 3.7 E < 3.9 9.7 10.4 13.6 14.9 12.1 14.3 14.2 3.9 E < 4.1 9.5 10.2 13.4 14.6 11.9 14.0 14.0 4.1 E < 4.3 9.3 9.9 13.1 14.3 11.7 13.7 13.7 4.3 E < 4.5 9.1 9.8 12.9 14.0 11.5 13.5 13.5 4.5 E < 4.7 9.0 9.6 12.6 13.8 11.3 13.3 13.3 4.7 E < 4.9 8.8 9.5 12.4 13.6 11.1 13.1 13.1 E 4.9 8.7 9.6 12.2 13.4 10.9 12.9 12.9
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-58 Amendment No. 9 Table B2-20 Loading Table for PWR Fuel - 876 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 54 < Assembly Average Burnup 55 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 11.2 12.0 15.6 17.0 13.9 16.3 16.3 3.3 E < 3.5 10.9 11.7 15.2 16.6 13.6 15.9 15.9 3.5 E < 3.7 10.6 11.4 14.9 16.2 13.3 15.6 15.6 3.7 E < 3.9 10.3 11.2 14.5 15.9 13.0 15.3 15.3 3.9 E < 4.1 10.0 10.9 14.2 15.6 12.7 15.0 14.9 4.1 E < 4.3 9.9 10.7 13.9 15.3 12.4 14.7 14.6 4.3 E < 4.5 9.7 10.5 13.7 15.1 12.2 14.4 14.4 4.5 E < 4.7 9.5 10.2 13.5 14.8 12.0 14.1 14.1 4.7 E < 4.9 9.3 10.0 13.3 14.6 11.8 13.9 13.9 E 4.9 9.2 9.9 13.1 14.3 11.6 13.8 13.7 Initial Assembly Avg. Enrichment wt % 235U (E) 55 < Assembly Average Burnup 56 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 11.9 12.8 16.6 18.1 14.5 17.4 17.3 3.3 E < 3.5 11.5 12.5 16.2 17.6 14.1 17.0 16.9 3.5 E < 3.7 11.3 12.1 15.8 17.3 13.7 16.6 16.6 3.7 E < 3.9 11.0 11.8 15.5 17.0 13.4 16.3 16.2 3.9 E < 4.1 10.7 11.6 15.2 16.6 13.2 15.9 15.9 4.1 E < 4.3 10.5 11.3 14.9 16.3 12.9 15.7 15.6 4.3 E < 4.5 10.2 11.1 14.6 16.0 12.6 15.4 15.3 4.5 E < 4.7 10.0 10.9 14.3 15.8 12.4 15.2 15.1 4.7 E < 4.9 9.9 10.7 14.1 15.6 12.2 14.9 14.9 E 4.9 9.7 10.5 13.9 15.3 12.0 14.7 14.6
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-59 Amendment No. 9 Table B2-20 Loading Table for PWR Fuel - 876 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 56 < Assembly Average Burnup 57 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 12.6 13.6 17.6 19.1 15.5 18.4 18.4 3.3 E < 3.5 12.3 13.3 17.2 18.7 15.0 18.0 18.0 3.5 E < 3.7 11.9 13.0 16.8 18.4 14.6 17.7 17.6 3.7 E < 3.9 11.7 12.6 16.5 18.0 14.3 17.3 17.3 3.9 E < 4.1 11.4 12.3 16.1 17.7 14.0 17.0 17.0 4.1 E < 4.3 11.2 12.0 15.8 17.4 13.7 16.7 16.7 4.3 E < 4.5 10.9 11.8 15.5 17.1 13.5 16.4 16.4 4.5 E < 4.7 10.7 11.6 15.3 16.8 13.2 16.1 16.1 4.7 E < 4.9 10.5 11.4 15.1 16.6 13.0 15.8 15.8 E 4.9 10.3 11.2 14.8 16.3 12.8 15.7 15.6 Initial Assembly Avg. Enrichment wt % 235U (E) 57 < Assembly Average Burnup 58 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 13.5 14.5 18.7 20.1 16.4 19.5 19.4 3.3 E < 3.5 13.1 14.1 18.3 19.8 15.9 19.1 19.0 3.5 E < 3.7 12.7 13.8 17.9 19.4 15.6 18.7 18.7 3.7 E < 3.9 12.4 13.4 17.5 19.0 15.3 18.4 18.3 3.9 E < 4.1 12.1 13.1 17.2 18.7 14.9 18.0 18.0 4.1 E < 4.3 11.8 12.9 16.9 18.4 14.6 17.7 17.7 4.3 E < 4.5 11.6 12.6 16.5 18.1 14.3 17.4 17.4 4.5 E < 4.7 11.4 12.3 16.3 17.8 14.0 17.2 17.1 4.7 E < 4.9 11.1 12.1 16.0 17.5 13.8 16.9 16.8 E 4.9 11.0 11.9 15.8 17.3 13.6 16.7 16.6
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-60 Amendment No. 9 Table B2-20 Loading Table for PWR Fuel - 876 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 58 < Assembly Average Burnup 59 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 14.3 15.4 19.7 21.2 17.4 20.5 20.5 3.3 E < 3.5 13.9 15.0 19.3 20.8 16.9 20.1 20.1 3.5 E < 3.7 13.5 14.7 18.9 20.4 16.6 19.8 19.7 3.7 E < 3.9 13.2 14.3 18.5 20.1 16.1 19.4 19.4 3.9 E < 4.1 12.9 14.0 18.2 19.7 15.8 19.1 19.0 4.1 E < 4.3 12.6 13.7 17.8 19.4 15.5 18.8 18.7 4.3 E < 4.5 12.2 13.4 17.6 19.1 15.2 18.4 18.4 4.5 E < 4.7 12.0 13.1 17.3 18.9 14.9 18.2 18.1 4.7 E < 4.9 11.8 12.9 17.0 18.6 14.7 17.9 17.8 E 4.9 11.6 12.7 16.8 18.4 14.5 17.6 17.6 Initial Assembly Avg. Enrichment wt % 235U (E) 59 < Assembly Average Burnup 60 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 3.3 E < 3.5 14.7 15.9 20.2 21.9 17.9 20.7 20.6 3.5 E < 3.7 14.3 15.6 19.9 21.5 17.5 20.3 20.2 3.7 E < 3.9 13.9 15.2 19.5 21.1 17.1 19.9 19.9 3.9 E < 4.1 13.6 14.9 19.2 20.8 16.8 19.6 19.5 4.1 E < 4.3 13.3 14.5 18.8 20.5 16.4 19.3 19.2 4.3 E < 4.5 13.1 14.2 18.5 20.2 16.1 18.9 18.9 4.5 E < 4.7 12.8 13.9 18.2 19.9 15.8 18.7 18.6 4.7 E < 4.9 12.5 13.7 18.0 19.6 15.6 18.4 18.3 E 4.9 12.3 13.5 17.7 19.4 15.4 18.2 18.1
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-61 Amendment No. 9 Table B2-21 Loading Table for PWR Fuel - 800 W/Assembly Initial Assembly Avg. Enrichment wt % 235U (E) 30 < Assembly Average Burnup 32.5 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 4.8 4.9 5.6 5.7 5.2 5.6 5.6 2.3 E < 2.5 4.7 4.8 5.5 5.7 5.2 5.6 5.6 2.5 E < 2.7 4.7 4.8 5.4 5.6 5.1 5.5 5.5 2.7 E < 2.9 4.6 4.7 5.4 5.5 5.0 5.5 5.5 2.9 E < 3.1 4.6 4.7 5.3 5.5 5.0 5.4 5.4 3.1 E < 3.3 4.5 4.6 5.3 5.4 5.0 5.3 5.3 3.3 E < 3.5 4.5 4.6 5.2 5.4 4.9 5.3 5.3 3.5 E < 3.7 4.5 4.5 5.1 5.3 4.9 5.2 5.2 3.7 E < 3.9 4.4 4.5 5.1 5.3 4.8 5.2 5.2 3.9 E < 4.1 4.4 4.5 5.0 5.2 4.8 5.2 5.1 4.1 E < 4.3 4.4 4.4 5.0 5.2 4.8 5.1 5.1 4.3 E < 4.5 4.3 4.4 5.0 5.1 4.8 5.1 5.1 4.5 E < 4.7 4.3 4.4 5.0 5.1 4.7 5.0 5.0 4.7 E < 4.9 4.3 4.4 4.9 5.1 4.7 5.0 5.0 E 4.9 4.3 4.3 4.9 5.0 4.7 5.0 5.0 Initial Assembly Avg. Enrichment wt % 235U (E) 32.5 < Assembly Average Burnup 35 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 5.2 5.3 6.0 6.3 5.7 6.1 6.1 2.5 E < 2.7 5.1 5.2 6.0 6.2 5.7 6.0 6.0 2.7 E < 2.9 5.0 5.2 5.9 6.1 5.6 6.0 6.0 2.9 E < 3.1 5.0 5.1 5.9 6.0 5.5 5.9 5.9 3.1 E < 3.3 4.9 5.0 5.8 6.0 5.5 5.9 5.9 3.3 E < 3.5 4.9 5.0 5.8 5.9 5.4 5.8 5.8 3.5 E < 3.7 4.9 4.9 5.7 5.9 5.4 5.8 5.8 3.7 E < 3.9 4.8 4.9 5.7 5.8 5.3 5.8 5.8 3.9 E < 4.1 4.8 4.9 5.6 5.8 5.3 5.7 5.7 4.1 E < 4.3 4.7 4.8 5.6 5.8 5.2 5.7 5.7 4.3 E < 4.5 4.7 4.8 5.5 5.7 5.2 5.6 5.6 4.5 E < 4.7 4.7 4.8 5.5 5.7 5.2 5.6 5.6 4.7 E < 4.9 4.6 4.7 5.5 5.7 5.1 5.6 5.6 E 4.9 4.6 4.7 5.4 5.6 5.1 5.5 5.5
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-62 Amendment No. 9 Table B2-21 Loading Table for PWR Fuel - 800 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 35 < Assembly Average Burnup 37.5 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 5.8 5.9 6.9 7.1 6.4 6.9 6.9 2.5 E < 2.7 5.7 5.8 6.8 7.0 6.3 6.8 6.8 2.7 E < 2.9 5.6 5.7 6.7 6.9 6.2 6.7 6.7 2.9 E < 3.1 5.5 5.7 6.6 6.8 6.1 6.7 6.7 3.1 E < 3.3 5.5 5.6 6.5 6.8 6.0 6.6 6.6 3.3 E < 3.5 5.4 5.5 6.4 6.7 6.0 6.5 6.5 3.5 E < 3.7 5.3 5.5 6.3 6.6 5.9 6.5 6.4 3.7 E < 3.9 5.3 5.4 6.3 6.5 5.9 6.4 6.4 3.9 E < 4.1 5.2 5.4 6.2 6.5 5.8 6.3 6.3 4.1 E < 4.3 5.2 5.3 6.1 6.4 5.8 6.3 6.3 4.3 E < 4.5 5.1 5.3 6.1 6.4 5.7 6.2 6.2 4.5 E < 4.7 5.1 5.2 6.0 6.3 5.7 6.2 6.2 4.7 E < 4.9 5.0 5.2 6.0 6.3 5.7 6.1 6.1 E 4.9 5.0 5.1 6.0 6.2 5.6 6.1 6.1 Initial Assembly Avg. Enrichment wt % 235U (E) 37.5 < Assembly Average Burnup 40 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 6.3 6.5 7.7 8.1 7.0 7.8 7.8 2.7 E < 2.9 6.2 6.4 7.6 8.0 6.9 7.7 7.7 2.9 E < 3.1 6.1 6.3 7.5 7.8 6.9 7.6 7.6 3.1 E < 3.3 6.0 6.2 7.4 7.7 6.8 7.4 7.4 3.3 E < 3.5 5.9 6.1 7.2 7.6 6.7 7.3 7.3 3.5 E < 3.7 5.9 6.0 7.1 7.5 6.6 7.3 7.2 3.7 E < 3.9 5.8 6.0 7.1 7.4 6.5 7.2 7.1 3.9 E < 4.1 5.8 5.9 7.0 7.4 6.5 7.1 7.1 4.1 E < 4.3 5.7 5.9 6.9 7.3 6.4 7.0 7.0 4.3 E < 4.5 5.7 5.8 6.9 7.2 6.4 7.0 7.0 4.5 E < 4.7 5.6 5.8 6.8 7.1 6.3 6.9 6.9 4.7 E < 4.9 5.6 5.7 6.8 7.1 6.3 6.9 6.9 E 4.9 5.5 5.7 6.7 7.0 6.2 6.8 6.8
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-63 Amendment No. 9 Table B2-21 Loading Table for PWR Fuel - 800 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 40 < Assembly Average Burnup 41 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 6.6 6.8 8.2 8.7 7.4 8.3 8.3 2.7 E < 2.9 6.5 6.7 8.0 8.5 7.3 8.1 8.1 2.9 E < 3.1 6.4 6.6 7.9 8.3 7.2 8.0 8.0 3.1 E < 3.3 6.3 6.5 7.8 8.2 7.1 7.9 7.9 3.3 E < 3.5 6.2 6.4 7.7 8.0 7.0 7.8 7.8 3.5 E < 3.7 6.1 6.3 7.6 8.0 6.9 7.7 7.7 3.7 E < 3.9 6.0 6.2 7.5 7.9 6.8 7.6 7.6 3.9 E < 4.1 6.0 6.1 7.4 7.8 6.8 7.5 7.5 4.1 E < 4.3 5.9 6.1 7.3 7.7 6.7 7.4 7.4 4.3 E < 4.5 5.9 6.0 7.2 7.6 6.7 7.4 7.3 4.5 E < 4.7 5.8 6.0 7.1 7.6 6.6 7.3 7.3 4.7 E < 4.9 5.8 5.9 7.1 7.5 6.6 7.2 7.2 E 4.9 5.7 5.9 7.0 7.4 6.5 7.2 7.2 Initial Assembly Avg. Enrichment wt % 235U (E) 41 < Assembly Average Burnup 42 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 6.9 7.1 8.7 9.3 7.8 8.8 8.8 2.7 E < 2.9 6.8 7.0 8.6 9.0 7.7 8.6 8.6 2.9 E < 3.1 6.7 6.9 8.4 8.9 7.6 8.5 8.5 3.1 E < 3.3 6.6 6.8 8.2 8.7 7.5 8.3 8.3 3.3 E < 3.5 6.5 6.7 8.1 8.6 7.3 8.2 8.2 3.5 E < 3.7 6.4 6.6 8.0 8.5 7.2 8.1 8.1 3.7 E < 3.9 6.3 6.5 7.9 8.3 7.1 8.0 8.0 3.9 E < 4.1 6.2 6.5 7.8 8.2 7.1 7.9 7.9 4.1 E < 4.3 6.1 6.4 7.7 8.1 7.0 7.8 7.8 4.3 E < 4.5 6.1 6.3 7.6 8.0 6.9 7.8 7.7 4.5 E < 4.7 6.0 6.3 7.6 8.0 6.9 7.7 7.7 4.7 E < 4.9 6.0 6.2 7.5 7.9 6.8 7.6 7.6 E 4.9 5.9 6.1 7.4 7.8 6.8 7.6 7.6
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-64 Amendment No. 9 Table B2-21 Loading Table for PWR Fuel - 800 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 42 < Assembly Average Burnup 43 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 7.3 7.5 9.3 9.9 8.3 9.4 9.4 2.7 E < 2.9 7.1 7.4 9.1 9.7 8.1 9.2 9.2 2.9 E < 3.1 7.0 7.2 8.9 9.5 8.0 9.0 9.0 3.1 E < 3.3 6.9 7.1 8.8 9.3 7.9 8.9 8.8 3.3 E < 3.5 6.8 7.0 8.6 9.2 7.8 8.7 8.7 3.5 E < 3.7 6.7 6.9 8.5 9.0 7.7 8.6 8.6 3.7 E < 3.9 6.6 6.8 8.4 8.9 7.6 8.5 8.5 3.9 E < 4.1 6.5 6.8 8.2 8.8 7.5 8.4 8.4 4.1 E < 4.3 6.5 6.7 8.1 8.7 7.4 8.3 8.3 4.3 E < 4.5 6.4 6.6 8.0 8.6 7.3 8.2 8.2 4.5 E < 4.7 6.3 6.6 8.0 8.5 7.2 8.1 8.1 4.7 E < 4.9 6.2 6.5 7.9 8.4 7.2 8.0 8.0 E 4.9 6.2 6.4 7.8 8.3 7.1 8.0 8.0 Initial Assembly Avg. Enrichment wt % 235U (E) 43 < Assembly Average Burnup 44 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 7.7 8.0 10.0 10.8 8.8 10.0 10.1 2.7 E < 2.9 7.5 7.8 9.7 10.5 8.7 9.9 9.8 2.9 E < 3.1 7.4 7.7 9.5 10.2 8.5 9.7 9.6 3.1 E < 3.3 7.2 7.5 9.3 10.0 8.3 9.5 9.4 3.3 E < 3.5 7.1 7.4 9.2 9.8 8.2 9.3 9.3 3.5 E < 3.7 7.1 7.3 9.0 9.7 8.0 9.1 9.1 3.7 E < 3.9 6.9 7.2 8.9 9.5 8.0 9.0 9.0 3.9 E < 4.1 6.8 7.1 8.8 9.4 7.9 8.9 8.9 4.1 E < 4.3 6.7 7.0 8.7 9.2 7.8 8.8 8.8 4.3 E < 4.5 6.7 6.9 8.5 9.1 7.7 8.7 8.7 4.5 E < 4.7 6.6 6.9 8.5 9.0 7.6 8.6 8.6 4.7 E < 4.9 6.6 6.8 8.4 8.9 7.6 8.5 8.5 E 4.9 6.5 6.8 8.3 8.9 7.5 8.5 8.4
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-65 Amendment No. 9 Table B2-21 Loading Table for PWR Fuel - 800 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 44 < Assembly Average Burnup 45 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 7.9 8.2 10.5 11.4 9.2 10.6 10.6 2.9 E < 3.1 7.8 8.1 10.2 11.1 9.0 10.4 10.4 3.1 E < 3.3 7.6 7.9 10.0 10.8 8.8 10.1 10.1 3.3 E < 3.5 7.5 7.8 9.8 10.6 8.7 9.9 9.9 3.5 E < 3.7 7.3 7.7 9.6 10.4 8.6 9.8 9.8 3.7 E < 3.9 7.2 7.6 9.5 10.2 8.4 9.6 9.6 3.9 E < 4.1 7.1 7.5 9.3 10.0 8.3 9.5 9.5 4.1 E < 4.3 7.0 7.4 9.2 9.9 8.2 9.4 9.3 4.3 E < 4.5 7.0 7.3 9.1 9.8 8.1 9.2 9.2 4.5 E < 4.7 6.9 7.2 9.0 9.7 8.0 9.1 9.1 4.7 E < 4.9 6.8 7.1 8.9 9.6 7.9 9.0 9.0 E 4.9 6.8 7.0 8.8 9.5 7.9 9.0 8.9
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-66 Amendment No. 9 Note: For fuel assembly average burnup greater than 45 GWd/MTU, cool time tables have been revised to account for a 5% margin in heat load.
Table B2-22 Loading Table for PWR Fuel - 760 W/Assembly Initial Assembly Avg. Enrichment wt % 235U (E) 45 < Assembly Average Burnup 46 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 9.2 9.8 12.8 13.9 11.2 13.0 13.0 2.9 E < 3.1 9.0 9.6 12.5 13.6 10.9 12.7 12.7 3.1 E < 3.3 8.9 9.4 12.1 13.3 10.6 12.4 12.4 3.3 E < 3.5 8.7 9.1 11.9 13.0 10.4 12.1 12.1 3.5 E < 3.7 8.6 9.0 11.8 12.8 10.2 11.9 11.9 3.7 E < 3.9 8.4 8.8 11.6 12.5 10.0 11.8 11.7 3.9 E < 4.1 8.3 8.7 11.4 12.3 9.9 11.6 11.5 4.1 E < 4.3 8.1 8.6 11.2 12.2 9.7 11.4 11.4 4.3 E < 4.5 8.0 8.5 11.1 12.0 9.6 11.3 11.3 4.5 E < 4.7 7.9 8.4 10.9 11.9 9.5 11.2 11.1 4.7 E < 4.9 7.9 8.3 10.8 11.7 9.4 11.0 11.0 E 4.9 7.8 8.2 10.7 11.6 9.3 10.9 10.9
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-67 Amendment No. 9 Table B2-22 Loading Table for PWR Fuel - 760 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 46 < Assembly Average Burnup 47 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 9.9 10.6 13.8 15.0 12.0 13.9 13.9 2.9 E < 3.1 9.7 10.3 13.5 14.7 11.7 13.7 13.7 3.1 E < 3.3 9.4 10.0 13.2 14.4 11.4 13.4 13.4 3.3 E < 3.5 9.2 9.8 12.9 14.0 11.2 13.1 13.1 3.5 E < 3.7 9.0 9.6 12.7 13.8 11.0 12.9 12.8 3.7 E < 3.9 8.9 9.4 12.4 13.6 10.8 12.6 12.6 3.9 E < 4.1 8.8 9.3 12.2 13.4 10.6 12.5 12.4 4.1 E < 4.3 8.6 9.1 12.0 13.2 10.4 12.2 12.2 4.3 E < 4.5 8.5 9.0 11.8 13.0 10.3 12.1 12.0 4.5 E < 4.7 8.4 8.9 11.7 12.8 10.1 11.9 11.9 4.7 E < 4.9 8.3 8.8 11.6 12.7 10.0 11.8 11.8 E 4.9 8.2 8.7 11.5 12.5 9.9 11.7 11.7 Initial Assembly Avg. Enrichment wt % 235U (E) 47 < Assembly Average Burnup 48 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 10.6 11.4 14.9 16.1 12.9 15.1 15.1 2.9 E < 3.1 10.4 11.1 14.5 15.8 12.5 14.7 14.7 3.1 E < 3.3 10.0 10.8 14.1 15.5 12.2 14.4 14.4 3.3 E < 3.5 9.9 10.5 13.9 15.2 12.0 14.1 14.0 3.5 E < 3.7 9.6 10.3 13.6 14.9 11.8 13.8 13.8 3.7 E < 3.9 9.5 10.1 13.4 14.6 11.6 13.6 13.6 3.9 E < 4.1 9.3 9.9 13.2 14.4 11.4 13.4 13.4 4.1 E < 4.3 9.1 9.8 13.0 14.1 11.2 13.2 13.2 4.3 E < 4.5 9.0 9.6 12.8 14.0 11.1 13.0 13.0 4.5 E < 4.7 8.9 9.5 12.6 13.8 10.9 12.9 12.8 4.7 E < 4.9 8.8 9.3 12.4 13.6 10.8 12.7 12.7 E 4.9 8.7 9.2 12.3 13.5 10.7 12.5 12.5
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-68 Amendment No. 9 Table B2-22 Loading Table for PWR Fuel - 760 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 48 < Assembly Average Burnup 49 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 11.4 12.2 16.0 17.3 13.9 16.2 16.2 2.9 E < 3.1 11.1 11.8 15.6 17.0 13.5 15.8 15.8 3.1 E < 3.3 10.8 11.6 15.3 16.6 13.2 15.5 15.5 3.3 E < 3.5 10.6 11.3 14.9 16.3 12.9 15.2 15.2 3.5 E < 3.7 10.3 11.1 14.7 16.0 12.7 14.9 14.9 3.7 E < 3.9 10.1 10.9 14.4 15.7 12.4 14.6 14.6 3.9 E < 4.1 9.9 10.7 14.1 15.5 12.1 14.4 14.4 4.1 E < 4.3 9.7 10.4 13.9 15.2 12.0 14.1 14.1 4.3 E < 4.5 9.6 10.2 13.7 15.0 11.8 13.9 13.9 4.5 E < 4.7 9.5 10.1 13.5 14.9 11.7 13.8 13.8 4.7 E < 4.9 9.3 9.9 13.4 14.6 11.5 13.6 13.6 E 4.9 9.2 9.8 13.2 14.5 11.4 13.5 13.5 Initial Assembly Avg. Enrichment wt % 235U (E) 49 < Assembly Average Burnup 50 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 11.9 12.4 16.8 18.2 14.5 17.0 17.0 3.1 E < 3.3 11.6 12.1 16.4 17.8 14.1 16.6 16.6 3.3 E < 3.5 11.3 11.8 16.0 17.5 13.8 16.3 16.2 3.5 E < 3.7 11.1 11.6 15.7 17.2 13.6 16.0 16.0 3.7 E < 3.9 10.8 11.4 15.5 16.9 13.3 15.7 15.7 3.9 E < 4.1 10.6 11.2 15.2 16.6 13.1 15.5 15.5 4.1 E < 4.3 10.4 11.0 14.9 16.3 12.9 15.3 15.2 4.3 E < 4.5 10.2 10.8 14.7 16.1 12.7 15.0 15.0 4.5 E < 4.7 10.1 10.6 14.5 15.9 12.5 14.9 14.8 4.7 E < 4.9 9.9 10.5 14.3 15.7 12.3 14.6 14.6 E 4.9 9.8 10.3 14.1 15.5 12.2 14.5 14.5
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-69 Amendment No. 9 Table B2-22 Loading Table for PWR Fuel - 760 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 50 < Assembly Average Burnup 51 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 12.4 13.4 17.8 19.3 15.6 18.1 18.1 3.1 E < 3.3 12.1 13.1 17.5 19.0 15.2 17.8 17.8 3.3 E < 3.5 11.8 12.7 17.2 18.7 14.9 17.4 17.4 3.5 E < 3.7 11.5 12.4 16.8 18.3 14.5 17.2 17.1 3.7 E < 3.9 11.3 12.1 16.5 18.0 14.3 16.9 16.8 3.9 E < 4.1 11.1 11.9 16.2 17.7 14.0 16.6 16.5 4.1 E < 4.3 10.9 11.7 16.0 17.5 13.8 16.3 16.3 4.3 E < 4.5 10.7 11.5 15.8 17.3 13.6 16.1 16.0 4.5 E < 4.7 10.5 11.4 15.5 17.1 13.4 15.8 15.9 4.7 E < 4.9 10.4 11.2 15.3 16.8 13.2 15.7 15.7 E 4.9 10.2 11.1 15.2 16.7 13.1 15.5 15.5 Initial Assembly Avg. Enrichment wt % 235U (E) 51 < Assembly Average Burnup 52 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 13.3 14.3 19.0 20.1 16.7 19.4 19.3 3.1 E < 3.3 12.9 14.0 18.6 19.7 16.3 19.0 18.9 3.3 E < 3.5 12.6 13.6 18.2 19.4 15.9 18.6 18.6 3.5 E < 3.7 12.3 13.3 17.9 19.1 15.6 18.3 18.3 3.7 E < 3.9 12.0 13.1 17.6 18.8 15.3 18.0 17.9 3.9 E < 4.1 11.8 12.8 17.4 18.5 15.0 17.7 17.7 4.1 E < 4.3 11.6 12.5 17.1 18.2 14.8 17.5 17.4 4.3 E < 4.5 11.4 12.3 16.8 18.0 14.5 17.3 17.2 4.5 E < 4.7 11.2 12.1 16.6 17.7 14.4 17.0 17.0 4.7 E < 4.9 11.1 11.9 16.4 17.5 14.1 16.8 16.8 E 4.9 10.9 11.8 16.2 17.4 13.9 16.6 16.5
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-70 Amendment No. 9 Table B2-22 Loading Table for PWR Fuel - 760 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 52 < Assembly Average Burnup 53 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 14.2 15.3 19.7 21.3 17.8 20.5 20.5 3.1 E < 3.3 13.8 15.0 19.3 20.9 17.4 20.1 20.1 3.3 E < 3.5 13.5 14.6 18.9 20.6 17.1 19.8 19.7 3.5 E < 3.7 13.1 14.3 18.6 20.3 16.7 19.5 19.4 3.7 E < 3.9 12.9 14.2 18.3 19.9 16.4 19.2 19.1 3.9 E < 4.1 12.6 13.7 18.0 19.6 16.0 18.9 18.8 4.1 E < 4.3 12.3 13.5 17.7 19.4 15.8 18.6 18.5 4.3 E < 4.5 12.1 13.2 17.5 19.1 15.6 18.4 18.3 4.5 E < 4.7 11.9 13.0 17.3 18.8 15.3 18.2 18.1 4.7 E < 4.9 11.8 12.8 17.0 18.7 15.2 17.9 17.8 E 4.9 11.6 12.6 16.9 18.5 14.9 17.7 17.7 Initial Assembly Avg. Enrichment wt % 235U (E) 53 < Assembly Average Burnup 54 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 15.2 16.4 20.9 22.5 18.9 21.7 21.6 3.1 E < 3.3 14.8 16.0 20.4 22.1 18.5 21.3 21.3 3.3 E < 3.5 14.4 15.6 20.0 21.8 18.1 21.0 20.9 3.5 E < 3.7 14.0 15.2 19.7 21.4 17.7 20.6 20.6 3.7 E < 3.9 13.7 14.9 19.4 21.1 17.4 20.3 20.3 3.9 E < 4.1 13.4 14.6 19.1 20.8 17.2 20.1 20.0 4.1 E < 4.3 13.2 14.4 18.9 20.5 16.9 19.8 19.7 4.3 E < 4.5 12.9 14.1 18.6 20.3 16.6 19.5 19.5 4.5 E < 4.7 12.7 13.9 18.3 20.1 16.4 19.3 19.2 4.7 E < 4.9 12.5 13.6 18.1 19.8 16.1 19.0 19.0 E 4.9 12.4 13.9 17.9 19.6 15.9 18.8 18.8
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-71 Amendment No. 9 Table B2-22 Loading Table for PWR Fuel - 760 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 54 < Assembly Average Burnup 55 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 15.7 17.1 21.6 23.2 19.6 22.5 22.4 3.3 E < 3.5 15.4 17.7 21.2 22.9 19.2 22.1 22.1 3.5 E < 3.7 15.0 16.3 20.9 22.6 18.9 21.8 21.8 3.7 E < 3.9 14.6 16.0 20.6 22.2 18.5 21.5 21.5 3.9 E < 4.1 14.4 15.7 20.2 21.9 18.3 21.2 21.2 4.1 E < 4.3 14.1 15.4 19.9 21.7 18.0 20.9 20.9 4.3 E < 4.5 13.8 15.1 19.7 21.4 17.7 20.7 20.6 4.5 E < 4.7 13.6 14.9 19.4 21.2 17.5 20.5 20.4 4.7 E < 4.9 13.4 14.6 19.2 21.0 17.2 20.2 20.1 E 4.9 13.2 14.4 19.0 20.7 17.0 19.9 19.9 Initial Assembly Avg. Enrichment wt % 235U (E) 55 < Assembly Average Burnup 56 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 16.8 18.1 22.7 24.4 20.2 23.6 23.6 3.3 E < 3.5 16.3 17.7 22.4 24.1 19.8 23.3 23.3 3.5 E < 3.7 15.9 17.3 21.9 23.7 19.5 23.0 22.9 3.7 E < 3.9 15.6 17.0 21.7 23.4 19.2 22.6 22.6 3.9 E < 4.1 15.3 16.7 21.4 23.1 18.8 22.4 22.3 4.1 E < 4.3 15.0 16.4 21.0 22.9 18.5 22.1 22.0 4.3 E < 4.5 14.8 16.1 20.8 22.6 18.3 21.8 21.8 4.5 E < 4.7 14.5 15.8 20.5 22.4 17.9 21.6 21.5 4.7 E < 4.9 14.3 15.6 20.3 22.2 17.8 21.3 21.3 E 4.9 14.0 15.4 20.0 21.9 17.6 21.1 21.1
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-72 Amendment No. 9 Table B2-22 Loading Table for PWR Fuel - 760 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 56 < Assembly Average Burnup 57 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 17.7 19.2 23.8 25.6 21.3 24.7 24.7 3.3 E < 3.5 17.3 18.8 23.4 25.2 20.9 24.4 24.4 3.5 E < 3.7 16.9 18.4 23.1 24.9 20.5 24.0 24.0 3.7 E < 3.9 16.6 18.1 22.7 24.6 20.2 23.7 23.7 3.9 E < 4.1 16.2 17.7 22.4 24.3 19.9 23.5 23.5 4.1 E < 4.3 15.9 17.4 22.2 24.0 19.6 23.2 23.2 4.3 E < 4.5 15.7 17.1 21.9 23.8 19.3 23.0 22.9 4.5 E < 4.7 15.4 16.8 21.6 23.5 19.1 22.7 22.6 4.7 E < 4.9 15.2 16.6 21.4 23.3 18.8 22.5 22.4 E 4.9 15.0 16.4 21.2 23.0 18.6 22.2 22.2 Initial Assembly Avg. Enrichment wt % 235U (E) 57 < Assembly Average Burnup 58 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 18.8 20.2 24.9 26.7 22.3 25.8 25.8 3.3 E < 3.5 18.3 19.9 24.6 26.3 22.0 25.5 25.5 3.5 E < 3.7 17.9 19.5 24.2 26.0 21.6 25.2 25.2 3.7 E < 3.9 17.6 19.1 23.9 25.7 21.3 24.9 24.8 3.9 E < 4.1 17.3 18.8 23.6 25.4 20.9 24.6 24.6 4.1 E < 4.3 16.9 18.4 23.3 25.1 20.6 24.4 24.3 4.3 E < 4.5 16.6 18.1 23.0 24.9 20.4 24.1 24.0 4.5 E < 4.7 16.3 17.9 22.8 24.6 20.0 23.8 23.8 4.7 E < 4.9 16.1 17.6 22.5 24.4 19.9 23.6 23.6 E 4.9 15.8 17.4 22.3 24.2 19.7 23.4 23.3
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-73 Amendment No. 9 Table B2-22 Loading Table for PWR Fuel - 760 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 58 < Assembly Average Burnup 59 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 19.8 21.3 25.9 27.7 23.4 26.9 26.9 3.3 E < 3.5 19.3 20.9 25.6 27.4 23.0 26.7 26.6 3.5 E < 3.7 18.9 20.5 25.3 27.1 22.7 26.3 26.2 3.7 E < 3.9 18.6 20.2 24.9 26.8 22.3 26.0 25.9 3.9 E < 4.1 18.2 19.8 24.6 26.5 22.0 25.7 25.7 4.1 E < 4.3 17.9 19.5 24.3 26.2 21.7 25.5 25.4 4.3 E < 4.5 17.6 19.2 24.1 26.0 21.4 25.2 25.2 4.5 E < 4.7 17.3 18.9 23.9 25.8 21.2 25.0 24.9 4.7 E < 4.9 17.1 18.7 23.6 25.5 20.9 24.7 24.7 E 4.9 16.8 18.4 23.4 25.3 20.7 24.5 24.4 Initial Assembly Avg. Enrichment wt % 235U (E) 59 < Assembly Average Burnup 60 GWd/MTU Minimum Cooling Time (years)
CE 1414 WE 1414 WE 1515 B&W 1515 CE 1616 WE 1717 B&W 1717 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 3.3 E < 3.5 20.3 22.0 26.7 28.4 24.1 27.2 27.1 3.5 E < 3.7 20.0 21.5 26.4 28.1 23.7 26.8 26.7 3.7 E < 3.9 19.6 21.2 26.0 27.8 23.4 26.5 26.5 3.9 E < 4.1 19.3 20.8 25.7 27.6 23.1 26.2 26.2 4.1 E < 4.3 18.9 20.5 25.4 27.3 22.7 26.0 25.9 4.3 E < 4.5 18.6 20.2 25.2 27.1 22.5 25.7 25.6 4.5 E < 4.7 18.3 20.0 24.9 26.8 22.2 25.5 25.4 4.7 E < 4.9 18.0 19.7 24.7 26.6 22.0 25.2 25.2 E 4.9 17.7 19.5 24.4 26.4 21.7 25.0 24.9
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-74 Amendment No. 9 Table B2-23 Loading Table for BWR Fuel - 379 W/Assembly Initial Assembly Avg. Enrichment wt % 235U (E) 30 < Assembly Average Burnup 32.5 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 4.3 4.6 4.0 4.5 4.0 4.5 4.4 2.3 E < 2.5 4.2 4.6 4.0 4.5 4.0 4.4 4.4 2.5 E < 2.7 4.2 4.5 4.0 4.4 4.0 4.4 4.3 2.7 E < 2.9 4.1 4.5 4.0 4.4 4.0 4.3 4.3 2.9 E < 3.1 4.1 4.4 4.0 4.3 4.0 4.3 4.2 3.1 E < 3.3 4.0 4.4 4.0 4.3 4.0 4.2 4.2 3.3 E < 3.5 4.0 4.3 4.0 4.2 4.0 4.2 4.1 3.5 E < 3.7 4.0 4.3 4.0 4.2 4.0 4.2 4.1 3.7 E < 3.9 4.0 4.3 4.0 4.2 4.0 4.1 4.0 3.9 E < 4.1 4.0 4.2 4.0 4.1 4.0 4.1 4.0 4.1 E < 4.3 4.0 4.2 4.0 4.1 4.0 4.1 4.0 4.3 E < 4.5 4.0 4.2 4.0 4.1 4.0 4.0 4.0 4.5 E < 4.7 4.0 4.1 4.0 4.0 4.0 4.0 4.0 4.7 E < 4.9 4.0 4.1 4.0 4.0 4.0 4.0 4.0 E 4.9 4.0 4.1 4.0 4.0 4.0 4.0 4.0 Initial Assembly Avg. Enrichment wt % 235U (E) 32.5 < Assembly Average Burnup 35 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 4.7 5.0 4.3 4.9 4.0 4.9 4.8 2.5 E < 2.7 4.6 4.9 4.3 4.8 4.0 4.8 4.7 2.7 E < 2.9 4.5 4.9 4.2 4.8 4.0 4.7 4.6 2.9 E < 3.1 4.5 4.8 4.2 4.7 4.0 4.7 4.6 3.1 E < 3.3 4.4 4.8 4.1 4.7 4.0 4.6 4.5 3.3 E < 3.5 4.4 4.7 4.0 4.6 4.0 4.6 4.5 3.5 E < 3.7 4.3 4.7 4.0 4.6 4.0 4.5 4.5 3.7 E < 3.9 4.3 4.6 4.0 4.5 4.0 4.5 4.4 3.9 E < 4.1 4.2 4.6 4.0 4.5 4.0 4.5 4.4 4.1 E < 4.3 4.2 4.5 4.0 4.5 4.0 4.4 4.3 4.3 E < 4.5 4.2 4.5 4.0 4.4 4.0 4.4 4.3 4.5 E < 4.7 4.1 4.5 4.0 4.4 4.0 4.4 4.3 4.7 E < 4.9 4.1 4.5 4.0 4.4 4.0 4.3 4.2 E 4.9 4.1 4.4 4.0 4.3 4.0 4.3 4.2
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-75 Amendment No. 9 Table B2-23 Loading Table for BWR Fuel - 379 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 35 < Assembly Average Burnup 37.5 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 5.2 5.6 4.7 5.4 4.4 5.4 5.2 2.5 E < 2.7 5.1 5.5 4.7 5.3 4.3 5.3 5.2 2.7 E < 2.9 5.0 5.4 4.6 5.3 4.3 5.2 5.1 2.9 E < 3.1 4.9 5.4 4.5 5.2 4.2 5.1 5.0 3.1 E < 3.3 4.9 5.3 4.5 5.1 4.1 5.1 4.9 3.3 E < 3.5 4.8 5.2 4.4 5.0 4.1 5.0 4.9 3.5 E < 3.7 4.8 5.1 4.4 5.0 4.0 4.9 4.8 3.7 E < 3.9 4.7 5.1 4.3 4.9 4.0 4.9 4.8 3.9 E < 4.1 4.6 5.0 4.3 4.9 4.0 4.9 4.7 4.1 E < 4.3 4.6 5.0 4.3 4.9 4.0 4.8 4.7 4.3 E < 4.5 4.6 4.9 4.2 4.8 4.0 4.8 4.7 4.5 E < 4.7 4.5 4.9 4.2 4.8 4.0 4.7 4.6 4.7 E < 4.9 4.5 4.9 4.1 4.7 4.0 4.7 4.6 E 4.9 4.5 4.9 4.1 4.7 4.0 4.7 4.6 Initial Assembly Avg. Enrichment wt % 235U (E) 37.5 < Assembly Average Burnup 40 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 5.7 6.1 5.2 5.9 4.7 5.9 5.7 2.7 E < 2.9 5.6 6.0 5.1 5.8 4.6 5.8 5.7 2.9 E < 3.1 5.5 5.9 5.0 5.8 4.6 5.7 5.6 3.1 E < 3.3 5.5 5.9 4.9 5.7 4.5 5.6 5.5 3.3 E < 3.5 5.4 5.8 4.9 5.6 4.4 5.6 5.4 3.5 E < 3.7 5.3 5.7 4.8 5.6 4.4 5.5 5.4 3.7 E < 3.9 5.2 5.7 4.7 5.5 4.3 5.4 5.3 3.9 E < 4.1 5.2 5.6 4.7 5.4 4.3 5.4 5.2 4.1 E < 4.3 5.1 5.6 4.6 5.4 4.3 5.3 5.2 4.3 E < 4.5 5.0 5.5 4.6 5.3 4.2 5.3 5.1 4.5 E < 4.7 5.0 5.5 4.5 5.3 4.2 5.2 5.0 4.7 E < 4.9 5.0 5.4 4.5 5.2 4.1 5.2 5.0 E 4.9 4.9 5.4 4.5 5.2 4.1 5.1 5.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-76 Amendment No. 9 Table B2-23 Loading Table for BWR Fuel - 379 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 40 < Assembly Average Burnup 41 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 6.0 6.5 5.4 6.2 4.9 6.1 6.0 2.7 E < 2.9 5.9 6.4 5.3 6.1 4.8 6.0 5.9 2.9 E < 3.1 5.8 6.2 5.2 6.0 4.7 5.9 5.8 3.1 E < 3.3 5.7 6.1 5.1 5.9 4.7 5.9 5.7 3.3 E < 3.5 5.6 6.0 5.0 5.9 4.6 5.8 5.6 3.5 E < 3.7 5.5 6.0 5.0 5.8 4.5 5.7 5.6 3.7 E < 3.9 5.5 5.9 4.9 5.7 4.5 5.7 5.5 3.9 E < 4.1 5.4 5.9 4.9 5.7 4.4 5.6 5.5 4.1 E < 4.3 5.3 5.8 4.8 5.6 4.4 5.5 5.4 4.3 E < 4.5 5.3 5.8 4.8 5.6 4.4 5.5 5.3 4.5 E < 4.7 5.2 5.7 4.7 5.5 4.3 5.4 5.3 4.7 E < 4.9 5.2 5.7 4.7 5.5 4.3 5.4 5.2 E 4.9 5.1 5.6 4.6 5.4 4.2 5.4 5.2 Initial Assembly Avg. Enrichment wt % 235U (E) 41 < Assembly Average Burnup 42 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 6.3 6.8 5.6 6.5 5.1 6.4 6.2 2.7 E < 2.9 6.2 6.7 5.5 6.4 5.0 6.3 6.1 2.9 E < 3.1 6.0 6.6 5.5 6.3 4.9 6.2 6.0 3.1 E < 3.3 6.0 6.5 5.4 6.2 4.8 6.1 5.9 3.3 E < 3.5 5.9 6.4 5.3 6.1 4.8 6.0 5.9 3.5 E < 3.7 5.8 6.3 5.2 6.0 4.7 5.9 5.8 3.7 E < 3.9 5.7 6.2 5.1 5.9 4.6 5.9 5.7 3.9 E < 4.1 5.6 6.1 5.0 5.9 4.6 5.8 5.7 4.1 E < 4.3 5.6 6.0 5.0 5.8 4.5 5.8 5.6 4.3 E < 4.5 5.5 6.0 4.9 5.8 4.5 5.7 5.6 4.5 E < 4.7 5.5 5.9 4.9 5.7 4.5 5.7 5.5 4.7 E < 4.9 5.4 5.9 4.9 5.7 4.4 5.6 5.5 E 4.9 5.4 5.8 4.8 5.6 4.4 5.6 5.4
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-77 Amendment No. 9 Table B2-23 Loading Table for BWR Fuel - 379 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 42 < Assembly Average Burnup 43 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 6.6 7.1 5.9 6.8 5.3 6.8 6.6 2.7 E < 2.9 6.5 7.0 5.8 6.7 5.2 6.6 6.4 2.9 E < 3.1 6.4 6.9 5.7 6.6 5.1 6.5 6.3 3.1 E < 3.3 6.3 6.8 5.6 6.5 5.0 6.4 6.2 3.3 E < 3.5 6.1 6.7 5.5 6.4 4.9 6.3 6.1 3.5 E < 3.7 6.0 6.6 5.4 6.3 4.9 6.2 6.0 3.7 E < 3.9 6.0 6.5 5.4 6.2 4.8 6.1 5.9 3.9 E < 4.1 5.9 6.4 5.3 6.1 4.8 6.0 5.9 4.1 E < 4.3 5.8 6.3 5.2 6.0 4.7 6.0 5.8 4.3 E < 4.5 5.8 6.3 5.1 6.0 4.6 5.9 5.8 4.5 E < 4.7 5.7 6.2 5.1 6.0 4.6 5.9 5.7 4.7 E < 4.9 5.7 6.1 5.0 5.9 4.6 5.9 5.7 E 4.9 5.6 6.1 5.0 5.9 4.5 5.8 5.6 Initial Assembly Avg. Enrichment wt % 235U (E) 43 < Assembly Average Burnup 44 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 7.0 7.6 6.1 7.2 5.5 7.1 6.9 2.7 E < 2.9 6.8 7.4 6.0 7.0 5.4 6.9 6.7 2.9 E < 3.1 6.7 7.3 5.9 6.9 5.3 6.8 6.6 3.1 E < 3.3 6.6 7.1 5.8 6.8 5.2 6.7 6.5 3.3 E < 3.5 6.5 7.0 5.7 6.7 5.1 6.6 6.4 3.5 E < 3.7 6.4 6.9 5.7 6.6 5.0 6.5 6.3 3.7 E < 3.9 6.3 6.8 5.6 6.5 5.0 6.5 6.2 3.9 E < 4.1 6.2 6.7 5.5 6.4 4.9 6.4 6.1 4.1 E < 4.3 6.1 6.7 5.5 6.4 4.9 6.3 6.0 4.3 E < 4.5 6.0 6.6 5.4 6.3 4.8 6.2 6.0 4.5 E < 4.7 5.9 6.5 5.3 6.2 4.8 6.1 5.9 4.7 E < 4.9 5.9 6.5 5.3 6.2 4.7 6.1 5.9 E 4.9 5.8 6.4 5.2 6.1 4.7 6.0 5.9
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-78 Amendment No. 9 Table B2-23 Loading Table for BWR Fuel - 379 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 44 < Assembly Average Burnup 45 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 7.2 7.9 6.3 7.5 5.6 7.4 7.1 2.9 E < 3.1 7.0 7.7 6.2 7.3 5.5 7.2 6.9 3.1 E < 3.3 6.9 7.6 6.1 7.1 5.4 7.0 6.8 3.3 E < 3.5 6.8 7.4 6.0 7.0 5.4 6.9 6.7 3.5 E < 3.7 6.7 7.3 5.9 6.9 5.3 6.9 6.6 3.7 E < 3.9 6.6 7.2 5.8 6.8 5.2 6.8 6.5 3.9 E < 4.1 6.5 7.1 5.8 6.8 5.1 6.7 6.4 4.1 E < 4.3 6.4 7.0 5.7 6.7 5.0 6.6 6.3 4.3 E < 4.5 6.3 6.9 5.6 6.6 5.0 6.5 6.3 4.5 E < 4.7 6.3 6.8 5.6 6.5 4.9 6.4 6.2 4.7 E < 4.9 6.2 6.8 5.5 6.5 4.9 6.4 6.1 E 4.9 6.1 6.7 5.4 6.4 4.8 6.3 6.1
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-79 Amendment No. 9 Note: For fuel assembly average burnup greater than 45 GWd/MTU, cool time tables have been revised to account for a 5% margin in heat load.
Table B2-24 Loading Table for BWR Fuel - 360 W/Assembly Initial Assembly Avg. Enrichment wt % 235U (E) 45 < Assembly Average Burnup 46 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 8.5 9.3 7.3 8.8 6.3 8.6 8.2 2.9 E < 3.1 8.3 9.0 7.1 8.6 6.2 8.4 8.0 3.1 E < 3.3 8.1 8.9 7.0 8.4 6.0 8.2 7.9 3.3 E < 3.5 8.0 8.8 6.8 8.2 6.0 8.0 7.7 3.5 E < 3.7 7.9 8.6 6.7 8.0 5.9 7.9 7.6 3.7 E < 3.9 7.7 8.4 6.7 7.9 5.8 7.8 7.5 3.9 E < 4.1 7.6 8.3 6.6 7.8 5.8 7.7 7.4 4.1 E < 4.3 7.5 8.2 6.5 7.7 5.7 7.6 7.3 4.3 E < 4.5 7.4 8.1 6.4 7.6 5.6 7.5 7.2 4.5 E < 4.7 7.3 8.0 6.3 7.6 5.6 7.4 7.1 4.7 E < 4.9 7.2 7.9 6.2 7.5 5.5 7.4 7.0 E 4.9 7.1 7.8 6.1 7.4 5.4 7.3 7.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-80 Amendment No. 9 Table B2-24 Loading Table for BWR Fuel - 360 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 46 < Assembly Average Burnup 47 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 9.1 10.0 7.7 9.3 6.7 9.2 8.7 2.9 E < 3.1 8.9 9.8 7.5 9.1 6.5 8.9 8.5 3.1 E < 3.3 8.7 9.5 7.4 8.9 6.4 8.8 8.3 3.3 E < 3.5 8.5 9.3 7.2 8.7 6.2 8.6 8.2 3.5 E < 3.7 8.3 9.1 7.0 8.6 6.1 8.4 8.0 3.7 E < 3.9 8.2 9.0 7.0 8.4 6.0 8.3 7.9 3.9 E < 4.1 8.0 8.8 6.9 8.3 6.0 8.1 7.8 4.1 E < 4.3 7.9 8.7 6.8 8.2 5.9 8.0 7.7 4.3 E < 4.5 7.8 8.6 6.7 8.1 5.8 7.9 7.6 4.5 E < 4.7 7.7 8.5 6.6 8.0 5.8 7.9 7.5 4.7 E < 4.9 7.6 8.4 6.5 7.9 5.7 7.8 7.4 E 4.9 7.5 8.3 6.5 7.8 5.7 7.7 7.4 Initial Assembly Avg. Enrichment wt % 235U (E) 47 < Assembly Average Burnup 48 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 9.8 10.7 8.2 9.9 6.9 9.8 9.3 2.9 E < 3.1 9.6 10.5 8.0 9.7 6.8 9.5 9.1 3.1 E < 3.3 9.3 10.2 7.8 9.5 6.7 9.3 8.9 3.3 E < 3.5 9.1 9.9 7.7 9.3 6.6 9.2 8.7 3.5 E < 3.7 8.9 9.7 7.5 9.1 6.5 9.0 8.5 3.7 E < 3.9 8.7 9.6 7.4 8.9 6.3 8.8 8.4 3.9 E < 4.1 8.6 9.4 7.2 8.8 6.2 8.7 8.2 4.1 E < 4.3 8.4 9.3 7.1 8.7 6.1 8.6 8.1 4.3 E < 4.5 8.3 9.1 7.0 8.6 6.0 8.4 8.0 4.5 E < 4.7 8.1 9.0 6.9 8.5 6.0 8.3 7.9 4.7 E < 4.9 8.0 8.9 6.9 8.3 5.9 8.2 7.8 E 4.9 7.9 8.8 6.8 8.2 5.9 8.1 7.8
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-81 Amendment No. 9 Table B2-24 Loading Table for BWR Fuel - 360 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 48 < Assembly Average Burnup 49 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 10.5 11.6 8.7 10.8 7.3 10.6 9.9 2.9 E < 3.1 10.2 11.3 8.5 10.4 7.1 10.2 9.7 3.1 E < 3.3 10.0 11.0 8.3 10.1 7.0 9.9 9.4 3.3 E < 3.5 9.7 10.7 8.1 9.9 6.9 9.8 9.2 3.5 E < 3.7 9.5 10.5 7.9 9.7 6.8 9.6 9.0 3.7 E < 3.9 9.3 10.3 7.8 9.5 6.7 9.4 8.9 3.9 E < 4.1 9.1 10.1 7.7 9.4 6.5 9.2 8.7 4.1 E < 4.3 9.0 9.9 7.5 9.2 6.4 9.0 8.6 4.3 E < 4.5 8.8 9.7 7.4 9.1 6.3 8.9 8.5 4.5 E < 4.7 8.7 9.6 7.3 8.9 6.3 8.8 8.4 4.7 E < 4.9 8.6 9.5 7.2 8.9 6.2 8.7 8.3 E 4.9 8.5 9.3 7.1 8.8 6.1 8.6 8.2 Initial Assembly Avg. Enrichment wt % 235U (E) 49 < Assembly Average Burnup 50 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 11.0 12.0 9.0 11.2 7.6 11.0 10.3 3.1 E < 3.3 10.7 11.7 8.8 10.9 7.4 10.7 10.1 3.3 E < 3.5 10.4 11.5 8.6 10.7 7.2 10.4 9.8 3.5 E < 3.7 10.2 11.3 8.4 10.4 7.0 10.2 9.7 3.7 E < 3.9 10.0 11.0 8.2 10.2 7.0 10.0 9.5 3.9 E < 4.1 9.7 10.8 8.0 10.0 6.8 9.8 9.3 4.1 E < 4.3 9.6 10.6 7.9 9.8 6.7 9.7 9.1 4.3 E < 4.5 9.4 10.4 7.8 9.7 6.7 9.5 9.0 4.5 E < 4.7 9.3 10.2 7.7 9.5 6.6 9.4 8.9 4.7 E < 4.9 9.1 10.1 7.6 9.4 6.5 9.2 8.7 E 4.9 9.0 10.0 7.5 9.3 6.4 9.1 8.6
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-82 Amendment No. 9 Table B2-24 Loading Table for BWR Fuel - 360 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 50 < Assembly Average Burnup 51 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 11.8 12.9 9.6 12.0 8.0 11.8 11.1 3.1 E < 3.3 11.5 12.6 9.4 11.7 7.8 11.5 10.9 3.3 E < 3.5 11.2 12.3 9.1 11.5 7.6 11.2 10.6 3.5 E < 3.7 10.9 11.9 8.9 11.1 7.5 11.0 10.3 3.7 E < 3.9 10.7 11.8 8.7 10.9 7.3 10.7 10.0 3.9 E < 4.1 10.4 11.6 8.6 10.7 7.2 10.5 9.9 4.1 E < 4.3 10.3 11.3 8.4 10.5 7.0 10.3 9.7 4.3 E < 4.5 10.0 11.2 8.3 10.4 7.0 10.1 9.6 4.5 E < 4.7 9.9 11.0 8.1 10.1 6.8 9.9 9.4 4.7 E < 4.9 9.8 10.9 8.0 10.0 6.8 9.8 9.3 E 4.9 9.6 10.7 7.9 9.9 6.7 9.7 9.1 Initial Assembly Avg. Enrichment wt % 235U (E) 51 < Assembly Average Burnup 52 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 12.7 13.9 10.3 12.9 8.4 12.6 11.9 3.1 E < 3.3 12.3 13.4 10.0 12.5 8.2 12.3 11.6 3.3 E < 3.5 11.9 13.2 9.8 12.1 8.0 11.9 11.3 3.5 E < 3.7 11.7 12.9 9.5 11.9 7.9 11.7 11.0 3.7 E < 3.9 11.5 12.6 9.3 11.7 7.7 11.4 10.8 3.9 E < 4.1 11.2 12.4 9.1 11.5 7.6 11.3 10.5 4.1 E < 4.3 11.0 12.1 8.9 11.3 7.4 11.0 10.3 4.3 E < 4.5 10.8 11.8 8.8 11.1 7.3 10.9 10.2 4.5 E < 4.7 10.6 11.7 8.7 10.9 7.2 10.7 10.0 4.7 E < 4.9 10.5 11.6 8.5 10.7 7.1 10.5 9.9 E 4.9 10.2 11.4 8.4 10.6 7.0 10.4 9.8
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-83 Amendment No. 9 Table B2-24 Loading Table for BWR Fuel - 360 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 52 < Assembly Average Burnup 53 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 13.6 14.8 11.0 13.7 8.9 13.4 12.7 3.1 E < 3.3 13.2 14.5 10.7 13.3 8.7 13.1 12.4 3.3 E < 3.5 12.8 14.1 10.4 13.0 8.5 12.8 12.0 3.5 E < 3.7 12.6 13.8 10.1 12.7 8.3 12.5 11.8 3.7 E < 3.9 12.2 13.5 9.8 12.4 8.1 12.2 11.5 3.9 E < 4.1 11.9 13.2 9.7 12.2 7.9 12.0 11.3 4.1 E < 4.3 11.7 13.0 9.5 12.0 7.8 11.8 11.1 4.3 E < 4.5 11.6 12.7 9.3 11.8 7.7 11.5 10.9 4.5 E < 4.7 11.4 12.5 9.2 11.6 7.6 11.4 10.7 4.7 E < 4.9 11.2 12.4 9.0 11.5 7.5 11.3 10.5 E 4.9 11.0 12.1 8.9 11.3 7.4 11.1 10.4 Initial Assembly Avg. Enrichment wt % 235U (E) 53 < Assembly Average Burnup 54 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 14.5 15.8 11.8 14.6 9.5 14.4 13.6 3.1 E < 3.3 14.1 15.4 11.4 14.3 9.2 14.0 13.2 3.3 E < 3.5 13.8 15.1 11.1 13.9 8.9 13.6 12.8 3.5 E < 3.7 13.4 14.7 10.9 13.6 8.7 13.4 12.6 3.7 E < 3.9 13.1 14.4 10.6 13.3 8.6 13.1 12.2 3.9 E < 4.1 12.9 14.1 10.4 13.1 8.4 12.8 12.0 4.1 E < 4.3 12.6 13.9 10.1 12.8 8.2 12.5 11.8 4.3 E < 4.5 12.4 13.6 9.9 12.6 8.1 12.3 11.6 4.5 E < 4.7 12.1 13.4 9.7 12.3 7.9 12.1 11.4 4.7 E < 4.9 11.9 13.2 9.6 12.2 7.9 11.9 11.2 E 4.9 11.7 13.1 9.4 12.0 7.8 11.7 11.1
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-84 Amendment No. 9 Table B2-24 Loading Table for BWR Fuel - 360 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 54 < Assembly Average Burnup 55 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 15.0 16.4 12.1 15.2 9.8 14.9 14.1 3.3 E < 3.5 14.7 16.0 11.9 14.9 9.5 14.6 13.7 3.5 E < 3.7 14.3 15.7 11.5 14.5 9.3 14.2 13.4 3.7 E < 3.9 13.9 15.4 11.3 14.2 9.0 13.9 13.1 3.9 E < 4.1 13.6 15.1 11.1 13.9 8.9 13.6 12.8 4.1 E < 4.3 13.3 14.7 10.8 13.6 8.7 13.4 12.5 4.3 E < 4.5 13.1 14.5 10.5 13.4 8.5 13.1 12.3 4.5 E < 4.7 12.9 14.3 10.4 13.2 8.4 13.0 12.1 4.7 E < 4.9 12.8 14.1 10.2 13.0 8.3 12.8 11.9 E 4.9 12.5 13.9 10.0 12.8 8.1 12.5 11.7 Initial Assembly Avg. Enrichment wt % 235U (E) 55 < Assembly Average Burnup 56 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 15.8 17.5 13.1 16.2 10.4 15.9 15.0 3.3 E < 3.5 15.5 17.1 12.7 15.8 10.1 15.5 14.6 3.5 E < 3.7 15.1 16.7 12.3 15.5 9.9 15.2 14.3 3.7 E < 3.9 14.7 16.3 12.0 15.1 9.7 14.8 13.9 3.9 E < 4.1 14.4 16.0 11.8 14.9 9.4 14.6 13.6 4.1 E < 4.3 14.0 15.7 11.5 14.5 9.2 14.3 13.4 4.3 E < 4.5 13.8 15.4 11.3 14.3 9.0 14.0 13.1 4.5 E < 4.7 13.7 15.2 11.1 14.1 8.8 13.8 12.9 4.7 E < 4.9 13.4 15.0 10.9 13.9 8.7 13.7 12.8 E 4.9 13.3 14.8 10.7 13.7 8.6 13.4 12.5
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-85 Amendment No. 9 Table B2-24 Loading Table for BWR Fuel - 360 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 56 < Assembly Average Burnup 57 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 16.8 18.4 13.8 17.2 11.1 16.9 16.0 3.3 E < 3.5 16.5 18.1 13.5 16.8 10.9 16.4 15.5 3.5 E < 3.7 16.0 17.7 13.1 16.4 10.5 16.2 15.2 3.7 E < 3.9 15.7 17.3 12.9 16.1 10.2 15.7 14.8 3.9 E < 4.1 15.4 17.1 12.5 15.8 10.0 15.4 14.5 4.1 E < 4.3 15.1 16.8 12.2 15.4 9.8 15.2 14.3 4.3 E < 4.5 14.8 16.4 12.0 15.2 9.6 14.8 14.0 4.5 E < 4.7 14.6 16.2 11.8 15.0 9.4 14.7 13.8 4.7 E < 4.9 14.3 15.9 11.6 14.7 9.2 14.4 13.5 E 4.9 14.0 15.7 11.4 14.5 9.0 14.3 13.4 Initial Assembly Avg. Enrichment wt % 235U (E) 57 < Assembly Average Burnup 58 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 17.8 19.5 14.8 18.2 11.8 17.8 16.8 3.3 E < 3.5 17.3 19.1 14.4 17.7 11.5 17.5 16.5 3.5 E < 3.7 17.0 18.7 14.0 17.4 11.2 17.1 16.1 3.7 E < 3.9 16.6 18.3 13.6 17.0 10.9 16.8 15.7 3.9 E < 4.1 16.3 17.9 13.3 16.7 10.6 16.4 15.4 4.1 E < 4.3 15.9 17.7 13.1 16.3 10.3 16.1 15.1 4.3 E < 4.5 15.7 17.4 12.8 16.1 10.1 15.8 14.8 4.5 E < 4.7 15.5 17.1 12.5 15.9 9.9 15.5 14.6 4.7 E < 4.9 15.2 16.9 12.3 15.6 9.8 15.3 14.4 E 4.9 15.0 16.7 12.1 15.4 9.6 15.1 14.2
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-86 Amendment No. 9 Table B2-24 Loading Table for BWR Fuel - 360 W/Assembly (continued)
Initial Assembly Avg. Enrichment wt % 235U (E) 58 < Assembly Average Burnup 59 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 18.7 20.4 15.7 19.2 12.6 18.9 17.8 3.3 E < 3.5 18.4 20.0 15.2 18.8 12.2 18.4 17.4 3.5 E < 3.7 18.0 19.7 14.9 18.4 11.9 18.1 17.1 3.7 E < 3.9 17.6 19.3 14.5 18.1 11.6 17.7 16.7 3.9 E < 4.1 17.2 18.9 14.1 17.7 11.2 17.3 16.3 4.1 E < 4.3 16.9 18.7 13.8 17.4 11.0 17.1 16.1 4.3 E < 4.5 16.6 18.4 13.6 17.1 10.8 16.8 15.7 4.5 E < 4.7 16.4 18.0 13.3 16.9 10.6 16.5 15.5 4.7 E < 4.9 16.1 17.8 13.1 16.6 10.3 16.2 15.3 E 4.9 15.9 17.6 12.9 16.3 10.2 15.9 15.1 Initial Assembly Avg. Enrichment wt % 235U (E) 59 < Assembly Average Burnup 60 GWd/MTU Minimum Cooling Time (years)
BWR/2-3 77 BWR/4-6 77 BWR/2-3 88 BWR/4-6 88 BWR/2-3 99 BWR/4-6 99 BWR/4-6 1010 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 3.3 E < 3.5 19.3 21.0 16.0 19.7 12.9 19.5 18.4 3.5 E < 3.7 18.9 20.7 15.6 19.3 12.7 19.1 17.9 3.7 E < 3.9 18.6 20.3 15.2 19.0 12.3 18.7 17.7 3.9 E < 4.1 18.2 19.9 14.9 18.7 11.9 18.3 17.3 4.1 E < 4.3 17.9 19.7 14.5 18.3 11.6 17.9 17.0 4.3 E < 4.5 17.6 19.4 14.2 18.1 11.4 17.7 16.6 4.5 E < 4.7 17.3 19.1 14.0 17.7 11.2 17.5 16.4 4.7 E < 4.9 17.1 18.8 13.8 17.6 11.0 17.2 16.1 E 4.9 16.9 18.6 13.6 17.3 10.8 16.9 15.9
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-87 Amendment No. 9 Table B2-25 Loading Table for PWR Fuel - 959 W/Assembly - WE 14x14 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU B 10 10< B 15< B 20< B 25< B 30< B 15 20 25 30 32.5 1.3 E < 1.5 2.5 1.5 E < 1.7 2.5 2.5 1.7 E < 1.9 2.5 2.5 2.9 1.9 E < 2.1 2.5 2.5 2.9 3.4 2.1 E < 2.3 2.5 2.5 2.8 3.3 3.9 4.1 2.3 E < 2.5 2.5 2.5 2.8 3.3 3.8 4.1 2.5 E < 2.7 2.5 2.5 2.8 3.3 3.8 4.0 2.7 E < 2.9 2.5 2.5 2.8 3.2 3.7 4.0 2.9 E < 3.1 2.5 2.5 2.7 3.2 3.7 3.9 3.1 E < 3.3 2.5 2.5 2.7 3.2 3.7 3.9 3.3 E < 3.5 2.5 2.5 2.7 3.2 3.6 3.9 3.5 E < 3.7 2.5 2.5 2.7 3.1 3.6 3.8 3.7 E < 3.9 2.5 2.5 2.7 3.1 3.6 3.8 3.9 E < 4.1 2.5 2.5 2.6 3.1 3.6 3.8 4.1 E < 4.3 2.5 2.5 2.6 3.1 3.5 3.8 4.3 E < 4.5 2.5 2.5 2.6 3.0 3.5 3.7 4.5 E < 4.7 2.5 2.5 2.6 3.0 3.5 3.7 4.7 E < 4.9 2.5 2.5 2.6 3.0 3.5 3.7 E 4.9 2.5 2.5 2.6 3.0 3.5 3.7
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-88 Amendment No. 9 Table B2-25 Loading Table for PWR Fuel - 959 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 32.5< B 35< B 37.5< B 40< B 41< B 42< B 35 37.5 40 41 42 43 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 4.4 4.8 2.5 E < 2.7 4.4 4.7 5.2 5.4 5.6 5.8 2.7 E < 2.9 4.3 4.7 5.1 5.3 5.5 5.7 2.9 E < 3.1 4.3 4.6 5.0 5.2 5.4 5.6 3.1 E < 3.3 4.2 4.5 4.9 5.1 5.3 5.6 3.3 E < 3.5 4.2 4.5 4.9 5.1 5.3 5.5 3.5 E < 3.7 4.1 4.5 4.8 5.0 5.2 5.4 3.7 E < 3.9 4.1 4.4 4.8 4.9 5.1 5.3 3.9 E < 4.1 4.1 4.4 4.8 4.9 5.1 5.3 4.1 E < 4.3 4.0 4.4 4.7 4.9 5.0 5.2 4.3 E < 4.5 4.0 4.3 4.7 4.8 5.0 5.2 4.5 E < 4.7 4.0 4.3 4.6 4.8 4.9 5.1 4.7 E < 4.9 4.0 4.3 4.6 4.7 4.9 5.0 E 4.9 3.9 4.2 4.5 4.7 4.9 5.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-89 Amendment No. 9 Table B2-25 Loading Table for PWR Fuel - 959 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B)
GWd/MTU 43< B 44< B 44 45k 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 6.0 2.7 E < 2.9 5.9 6.2 2.9 E < 3.1 5.8 6.0 3.1 E < 3.3 5.8 6.0 3.3 E < 3.5 5.7 5.9 3.5 E < 3.7 5.6 5.8 3.7 E < 3.9 5.6 5.8 3.9 E < 4.1 5.5 5.7 4.1 E < 4.3 5.4 5.6 4.3 E < 4.5 5.4 5.6 4.5 E < 4.7 5.3 5.5 4.7 E < 4.9 5.3 5.5 E 4.9 5.2 5.4 k Cool times for burnup over 45 GWd/MTU are in Table B2-16
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-90 Amendment No. 9 Table B2-26 Loading Table for PWR Fuel - 513 W/Assembly - WE 14x14 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU B 10 10< B 15< B 20< B 25< B 30< B 15 20 25 30 32.5 1.3 E < 1.5 2.9 1.5 E < 1.7 2.9 3.8 1.7 E < 1.9 2.9 3.7 4.5 1.9 E < 2.1 2.9 3.7 4.5 5.7 2.1 E < 2.3 2.8 3.7 4.5 5.7 7.5 8.9 2.3 E < 2.5 2.8 3.6 4.4 5.6 7.4 8.8 2.5 E < 2.7 2.8 3.6 4.4 5.6 7.3 8.6 2.7 E < 2.9 2.8 3.6 4.4 5.5 7.2 8.5 2.9 E < 3.1 2.8 3.5 4.4 5.5 7.1 8.5 3.1 E < 3.3 2.8 3.5 4.3 5.5 7.1 8.4 3.3 E < 3.5 2.8 3.5 4.3 5.4 7.0 8.3 3.5 E < 3.7 2.7 3.5 4.3 5.4 7.0 8.2 3.7 E < 3.9 2.7 3.5 4.3 5.4 7.0 8.1 3.9 E < 4.1 2.7 3.5 4.3 5.3 6.9 8.1 4.1 E < 4.3 2.7 3.5 4.2 5.3 6.9 8.0 4.3 E < 4.5 2.7 3.5 4.2 5.3 6.8 8.0 4.5 E < 4.7 2.7 3.5 4.2 5.2 6.8 7.9 4.7 E < 4.9 2.7 3.4 4.2 5.2 6.8 7.9 E 4.9 2.7 3.4 4.2 5.2 6.8 7.9
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-91 Amendment No. 9 Table B2-26 Loading Table for PWR Fuel - 513 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 32.5< B 35< B 37.5< B 40< B 41< B 42< B 35 37.5 40 41 42 43 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 10.9 13.7 2.5 E < 2.7 10.7 13.5 16.9 18.2 19.7 21.2 2.7 E < 2.9 10.5 13.3 16.5 18.0 19.4 20.8 2.9 E < 3.1 10.4 13.1 16.3 17.7 19.2 20.6 3.1 E < 3.3 10.2 12.8 16.0 17.5 18.9 20.4 3.3 E < 3.5 10.1 12.7 15.9 17.2 18.7 20.1 3.5 E < 3.7 10.0 12.5 15.6 17.0 18.4 19.9 3.7 E < 3.9 9.9 12.4 15.5 16.8 18.2 19.6 3.9 E < 4.1 9.8 12.3 15.3 16.7 18.0 19.5 4.1 E < 4.3 9.8 12.1 15.2 16.5 17.9 19.3 4.3 E < 4.5 9.7 12.0 15.1 16.3 17.7 19.2 4.5 E < 4.7 9.7 11.9 15.0 16.2 17.6 19.0 4.7 E < 4.9 9.6 11.9 14.9 16.1 17.5 18.8 E 4.9 9.5 11.8 14.8 16.0 17.3 18.7
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-92 Amendment No. 9 Table B2-26 Loading Table for PWR Fuel - 513 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B)
GWd/MTU 43< B 44< B 44 45 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 22.7 2.7 E < 2.9 22.3 23.8 2.9 E < 3.1 22.1 23.5 3.1 E < 3.3 21.8 23.2 3.3 E < 3.5 21.6 22.9 3.5 E < 3.7 21.3 22.7 3.7 E < 3.9 21.1 22.5 3.9 E < 4.1 20.9 22.3 4.1 E < 4.3 20.8 22.1 4.3 E < 4.5 20.6 21.9 4.5 E < 4.7 20.4 21.8 4.7 E < 4.9 20.3 21.6 E 4.9 20.1 21.5
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-93 Amendment No. 9 Table B2-27 Loading Table for PWR Fuel - 1300 W/Assembly - WE 14x14 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU B 10 10< B 15< B 20< B 25< B 30< B 15 20 25 30 32.5 1.3 E < 1.5 2.5 1.5 E < 1.7 2.5 2.5 1.7 E < 1.9 2.5 2.5 2.5 1.9 E < 2.1 2.5 2.5 2.5 2.7 2.1 E < 2.3 2.5 2.5 2.5 2.6 3.0 3.2 2.3 E < 2.5 2.5 2.5 2.5 2.6 3.0 3.2 2.5 E < 2.7 2.5 2.5 2.5 2.6 3.0 3.1 2.7 E < 2.9 2.5 2.5 2.5 2.6 2.9 3.1 2.9 E < 3.1 2.5 2.5 2.5 2.5 2.9 3.0 3.1 E < 3.3 2.5 2.5 2.5 2.5 2.9 3.0 3.3 E < 3.5 2.5 2.5 2.5 2.5 2.9 3.0 3.5 E < 3.7 2.5 2.5 2.5 2.5 2.8 3.0 3.7 E < 3.9 2.5 2.5 2.5 2.5 2.8 3.0 3.9 E < 4.1 2.5 2.5 2.5 2.5 2.8 2.9 4.1 E < 4.3 2.5 2.5 2.5 2.5 2.8 2.9 4.3 E < 4.5 2.5 2.5 2.5 2.5 2.8 2.9 4.5 E < 4.7 2.5 2.5 2.5 2.5 2.7 2.9 4.7 E < 4.9 2.5 2.5 2.5 2.5 2.7 2.9 E 4.9 2.5 2.5 2.5 2.5 2.7 2.8
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-94 Amendment No. 9 Table B2-27 Loading Table for PWR Fuel - 1300 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 32.5< B 35< B 37.5< B 40< B 41< B 42< B 35 37.5 40 41 42 43 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 3.4 3.6 2.5 E < 2.7 3.3 3.6 3.8 3.9 4.0 4.1 2.7 E < 2.9 3.3 3.5 3.8 3.9 4.0 4.1 2.9 E < 3.1 3.3 3.5 3.7 3.8 3.9 4.0 3.1 E < 3.3 3.2 3.4 3.7 3.8 3.9 4.0 3.3 E < 3.5 3.2 3.4 3.6 3.7 3.8 3.9 3.5 E < 3.7 3.2 3.4 3.6 3.7 3.8 3.9 3.7 E < 3.9 3.1 3.4 3.6 3.6 3.8 3.9 3.9 E < 4.1 3.1 3.3 3.5 3.6 3.7 3.8 4.1 E < 4.3 3.1 3.3 3.5 3.6 3.7 3.8 4.3 E < 4.5 3.0 3.3 3.5 3.6 3.6 3.8 4.5 E < 4.7 3.0 3.2 3.4 3.5 3.6 3.7 4.7 E < 4.9 3.0 3.2 3.4 3.5 3.6 3.7 E 4.9 3.0 3.2 3.4 3.5 3.5 3.7
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-95 Amendment No. 9 Table B2-27 Loading Table for PWR Fuel - 1300 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B)
GWd/MTU 43< B 44< B 44 45 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 4.3 2.7 E < 2.9 4.2 4.3 2.9 E < 3.1 4.2 4.3 3.1 E < 3.3 4.1 4.2 3.3 E < 3.5 4.0 4.2 3.5 E < 3.7 4.0 4.1 3.7 E < 3.9 4.0 4.0 3.9 E < 4.1 3.9 4.0 4.1 E < 4.3 3.9 4.0 4.3 E < 4.5 3.8 3.9 4.5 E < 4.7 3.9 3.9 4.7 E < 4.9 3.8 3.9 E 4.9 3.8 3.8
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-96 Amendment No. 9 Table B2-28 Loading Table for PWR Fuel - 1800 W/Assembly - WE 14x14 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU B 10 10< B 15< B 20< B 25< B 30< B 15 20 25 30 32.5 1.3 E < 1.5 2.5 1.5 E < 1.7 2.5 2.5 1.7 E < 1.9 2.5 2.5 2.5 1.9 E < 2.1 2.5 2.5 2.5 2.5 2.1 E < 2.3 2.5 2.5 2.5 2.5 2.5 2.5 2.3 E < 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 E < 2.7 2.5 2.5 2.5 2.5 2.5 2.5 2.7 E < 2.9 2.5 2.5 2.5 2.5 2.5 2.5 2.9 E < 3.1 2.5 2.5 2.5 2.5 2.5 2.5 3.1 E < 3.3 2.5 2.5 2.5 2.5 2.5 2.5 3.3 E < 3.5 2.5 2.5 2.5 2.5 2.5 2.5 3.5 E < 3.7 2.5 2.5 2.5 2.5 2.5 2.5 3.7 E < 3.9 2.5 2.5 2.5 2.5 2.5 2.5 3.9 E < 4.1 2.5 2.5 2.5 2.5 2.5 2.5 4.1 E < 4.3 2.5 2.5 2.5 2.5 2.5 2.5 4.3 E < 4.5 2.5 2.5 2.5 2.5 2.5 2.5 4.5 E < 4.7 2.5 2.5 2.5 2.5 2.5 2.5 4.7 E < 4.9 2.5 2.5 2.5 2.5 2.5 2.5 E 4.9 2.5 2.5 2.5 2.5 2.5 2.5
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-97 Amendment No. 9 Table B2-28 Loading Table for PWR Fuel - 1800 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 32.5< B 35< B 37.5< B 40< B 41< B 42< B 35 37.5 40 41 42 43 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.6 2.7 2.5 E < 2.7 2.5 2.7 2.9 2.9 3.0 3.1 2.7 E < 2.9 2.5 2.7 2.8 2.9 3.0 3.0 2.9 E < 3.1 2.5 2.6 2.8 2.9 2.9 3.0 3.1 E < 3.3 2.5 2.6 2.8 2.8 2.9 3.0 3.3 E < 3.5 2.5 2.6 2.7 2.8 2.9 2.9 3.5 E < 3.7 2.5 2.5 2.7 2.8 2.8 2.9 3.7 E < 3.9 2.5 2.5 2.7 2.7 2.8 2.9 3.9 E < 4.1 2.5 2.5 2.6 2.7 2.8 2.8 4.1 E < 4.3 2.5 2.5 2.6 2.7 2.8 2.8 4.3 E < 4.5 2.5 2.5 2.6 2.7 2.7 2.8 4.5 E < 4.7 2.5 2.5 2.6 2.6 2.7 2.8 4.7 E < 4.9 2.5 2.5 2.5 2.6 2.7 2.7 E 4.9 2.5 2.5 2.5 2.6 2.6 2.7
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-98 Amendment No. 9 Table B2-28 Loading Table for PWR Fuel - 1800 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B)
GWd/MTU 43< B 44< B 44 45 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 3.1 2.7 E < 2.9 3.1 3.2 2.9 E < 3.1 3.1 3.1 3.1 E < 3.3 3.0 3.1 3.3 E < 3.5 3.0 3.1 3.5 E < 3.7 3.0 3.0 3.7 E < 3.9 2.9 3.0 3.9 E < 4.1 2.9 3.0 4.1 E < 4.3 2.9 2.9 4.3 E < 4.5 2.8 2.9 4.5 E < 4.7 2.9 2.9 4.7 E < 4.9 2.8 2.9 E 4.9 2.8 2.8
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-99 Amendment No. 9 Table B2-29 Loading Table for PWR Fuel - 830 W/Assembly - WE 14x14 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU B 10 10< B 15< B 20< B 25< B 30< B 15 20 25 30 32.5 1.3 E < 1.5 2.5 1.5 E < 1.7 2.5 2.7 1.7 E < 1.9 2.5 2.7 3.2 1.9 E < 2.1 2.5 2.7 3.2 3.8 2.1 E < 2.3 2.5 2.6 3.1 3.7 4.4 4.7 2.3 E < 2.5 2.5 2.6 3.1 3.7 4.3 4.6 2.5 E < 2.7 2.5 2.6 3.1 3.6 4.3 4.6 2.7 E < 2.9 2.5 2.6 3.0 3.6 4.2 4.5 2.9 E < 3.1 2.5 2.5 3.0 3.6 4.2 4.5 3.1 E < 3.3 2.5 2.5 3.0 3.5 4.2 4.5 3.3 E < 3.5 2.5 2.5 3.0 3.5 4.1 4.4 3.5 E < 3.7 2.5 2.5 3.0 3.5 4.1 4.4 3.7 E < 3.9 2.5 2.5 3.0 3.5 4.0 4.4 3.9 E < 4.1 2.5 2.5 2.9 3.5 4.0 4.3 4.1 E < 4.3 2.5 2.5 2.9 3.4 4.0 4.3 4.3 E < 4.5 2.5 2.5 2.9 3.4 4.0 4.3 4.5 E < 4.7 2.5 2.5 2.9 3.4 4.0 4.2 4.7 E < 4.9 2.5 2.5 2.9 3.4 3.9 4.2 E 4.9 2.5 2.5 2.9 3.4 3.9 4.2
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-100 Amendment No. 9 Table B2-29 Loading Table for PWR Fuel - 830 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 32.5< B 35< B 37.5< B 40< B 41< B 42< B 35 37.5 40 41 42 43 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 5.1 5.6 2.5 E < 2.7 5.0 5.6 6.1 6.4 6.8 7.1 2.7 E < 2.9 5.0 5.5 6.0 6.3 6.6 6.9 2.9 E < 3.1 4.9 5.4 6.0 6.2 6.5 6.8 3.1 E < 3.3 4.9 5.4 5.9 6.1 6.4 6.7 3.3 E < 3.5 4.8 5.3 5.8 6.0 6.3 6.6 3.5 E < 3.7 4.8 5.2 5.8 6.0 6.3 6.6 3.7 E < 3.9 4.7 5.2 5.7 5.9 6.2 6.5 3.9 E < 4.1 4.7 5.1 5.7 5.9 6.1 6.4 4.1 E < 4.3 4.6 5.1 5.6 5.8 6.0 6.3 4.3 E < 4.5 4.6 5.0 5.6 5.8 6.0 6.2 4.5 E < 4.7 4.6 5.0 5.5 5.7 5.9 6.2 4.7 E < 4.9 4.5 5.0 5.5 5.7 5.9 6.1 E 4.9 4.5 4.9 5.4 5.6 5.9 6.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-101 Amendment No. 9 Table B2-29 Loading Table for PWR Fuel - 830 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B)
GWd/MTU 43< B 44< B 44 45 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 7.5 2.7 E < 2.9 7.3 7.7 2.9 E < 3.1 7.2 7.6 3.1 E < 3.3 7.0 7.5 3.3 E < 3.5 6.9 7.3 3.5 E < 3.7 6.8 7.2 3.7 E < 3.9 6.8 7.1 3.9 E < 4.1 6.7 7.0 4.1 E < 4.3 6.6 6.9 4.3 E < 4.5 6.6 6.8 4.5 E < 4.7 6.5 6.8 4.7 E < 4.9 6.4 6.7 E 4.9 6.4 6.7
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-102 Amendment No. 9 Note: For fuel assembly average burnup greater than 45 GWd/MTU, cool time tables have been revised to account for a 5% margin in heat load.
Table B2-30 Loading Table for PWR Fuel - 487 W/Assembly - WE 14x14 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 45< B 46< B 47< B 48< B 49< B 50< B 46 47 48 49 50 51 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 27.9 29.3 30.7 32.0 2.9 E < 3.1 27.6 29.0 30.4 31.8 32.7 33.9 3.1 E < 3.3 27.4 28.8 30.2 31.6 32.4 33.7 3.3 E < 3.5 27.1 28.5 30.0 31.4 32.2 33.6 3.5 E < 3.7 26.9 28.3 29.7 31.1 32.0 33.3 3.7 E < 3.9 26.7 28.1 29.5 30.9 31.8 33.1 3.9 E < 4.1 26.6 27.9 29.4 30.8 31.6 32.9 4.1 E < 4.3 26.3 27.8 29.2 30.6 31.4 33.5 4.3 E < 4.5 26.1 27.5 29.0 30.3 31.2 32.6 4.5 E < 4.7 26.0 27.4 28.8 30.2 31.1 32.4 4.7 E < 4.9 25.9 27.3 28.6 30.1 30.9 32.3 E 4.9 25.8 27.1 28.5 30.0 30.8 32.1
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-103 Amendment No. 9 Table B2-30 Loading Table for PWR Fuel - 487 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 51< B 52< B 53< B 54< B 55< B 56< B 52 53 54 55 56 57 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 35.2 36.4 37.7 3.1 E < 3.3 35.0 36.2 37.4 38.8 39.8 41.0 3.3 E < 3.5 34.8 36.0 37.2 38.5 39.6 40.9 3.5 E < 3.7 34.5 35.9 37.1 38.4 39.5 40.7 3.7 E < 3.9 34.3 35.6 36.9 38.2 39.4 40.5 3.9 E < 4.1 34.2 35.4 36.7 38.1 39.2 40.4 4.1 E < 4.3 34.1 35.2 36.6 37.9 39.2 40.2 4.3 E < 4.5 33.9 35.2 36.4 37.7 39.0 40.2 4.5 E < 4.7 33.7 35.0 36.3 37.6 38.8 40.0 4.7 E < 4.9 33.5 34.8 36.1 37.4 38.7 39.8 E 4.9 33.4 34.7 35.9 37.3 38.6 39.7
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-104 Amendment No. 9 Table B2-30 Loading Table for PWR Fuel - 487 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 57< B 58< B 59< B 58 59 60 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 42.1 43.3 3.3 E < 3.5 42.0 43.1 44.1 3.5 E < 3.7 41.9 43.0 44.1 3.7 E < 3.9 41.7 42.9 43.9 3.9 E < 4.1 41.6 42.7 43.8 4.1 E < 4.3 41.5 42.6 43.7 4.3 E < 4.5 41.3 42.5 43.6 4.5 E < 4.7 41.2 42.4 43.5 4.7 E < 4.9 41.0 42.3 43.4 E 4.9 40.9 42.1 43.3
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-105 Amendment No. 9 Table B2-31 Loading Table for PWR Fuel - 1235 W/Assembly - WE 14x14 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 45< B 46< B 47< B 48< B 49< B 50< B 46 47 48 49 50 51 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 4.7 4.9 5.0 5.2 2.9 E < 3.1 4.6 4.8 4.9 5.1 5.2 5.4 3.1 E < 3.3 4.6 4.7 4.9 5.0 5.1 5.3 3.3 E < 3.5 4.5 4.6 4.8 4.9 5.0 5.2 3.5 E < 3.7 4.5 4.6 4.7 4.9 5.0 5.2 3.7 E < 3.9 4.4 4.5 4.7 4.8 4.9 5.1 3.9 E < 4.1 4.4 4.5 4.6 4.8 4.9 5.0 4.1 E < 4.3 4.3 4.4 4.5 4.7 4.8 4.9 4.3 E < 4.5 4.3 4.4 4.5 4.6 4.8 4.9 4.5 E < 4.7 4.2 4.3 4.5 4.6 4.7 4.8 4.7 E < 4.9 4.2 4.3 4.4 4.6 4.7 4.8 E 4.9 4.1 4.3 4.4 4.5 4.6 4.7
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-106 Amendment No. 9 Table B2-31 Loading Table for PWR Fuel - 1235 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 51< B 52< B 53< B 54< B 55< B 56< B 52 53 54 55 56 57 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 5.6 5.8 6.0 3.1 E < 3.3 5.5 5.7 5.9 6.1 6.4 6.7 3.3 E < 3.5 5.4 5.6 5.8 6.0 6.3 6.5 3.5 E < 3.7 5.4 5.5 5.7 5.9 6.1 6.4 3.7 E < 3.9 5.3 5.5 5.6 5.8 6.0 6.3 3.9 E < 4.1 5.2 5.4 5.6 5.8 5.9 6.1 4.1 E < 4.3 5.1 5.3 5.5 5.7 5.9 6.0 4.3 E < 4.5 5.0 5.2 5.4 5.6 5.8 6.0 4.5 E < 4.7 5.0 5.1 5.3 5.5 5.7 5.9 4.7 E < 4.9 4.9 5.1 5.3 5.5 5.6 5.8 E 4.9 4.9 5.0 5.3 5.4 5.6 5.7
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-107 Amendment No. 9 Table B2-31 Loading Table for PWR Fuel - 1235 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 57< B 58< B 59< B 58 59 60 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 6.9 7.2 3.3 E < 3.5 6.8 7.0 7.4 3.5 E < 3.7 6.7 6.9 7.2 3.7 E < 3.9 6.5 6.8 7.0 3.9 E < 4.1 6.4 6.7 6.9 4.1 E < 4.3 6.3 6.5 6.8 4.3 E < 4.5 6.2 6.4 6.7 4.5 E < 4.7 6.1 6.3 6.6 4.7 E < 4.9 6.0 6.2 6.5 E 4.9 5.9 6.1 6.4
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-108 Amendment No. 9 Table B2-32 Loading Table for PWR Fuel - 1710 W/Assembly - WE 14x14 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 45< B 46< B 47< B 48< B 49< B 50< B 46 47 48 49 50 51 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 3.4 3.5 3.6 3.7 2.9 E < 3.1 3.4 3.5 3.5 3.6 3.7 3.8 3.1 E < 3.3 3.3 3.4 3.5 3.6 3.6 3.7 3.3 E < 3.5 3.3 3.4 3.4 3.5 3.6 3.7 3.5 E < 3.7 3.3 3.3 3.4 3.5 3.5 3.6 3.7 E < 3.9 3.2 3.3 3.4 3.4 3.5 3.6 3.9 E < 4.1 3.2 3.3 3.3 3.4 3.5 3.5 4.1 E < 4.3 3.1 3.2 3.3 3.4 3.4 3.5 4.3 E < 4.5 3.1 3.2 3.3 3.3 3.4 3.5 4.5 E < 4.7 3.1 3.2 3.2 3.3 3.4 3.4 4.7 E < 4.9 3.0 3.1 3.2 3.3 3.4 3.4 E 4.9 3.0 3.1 3.2 3.2 3.3 3.4
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-109 Amendment No. 9 Table B2-32 Loading Table for PWR Fuel - 1710 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 51< B 52< B 53< B 54< B 55< B 56< B 52 53 54 55 56 57 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.9 4.0 4.0 3.1 E < 3.3 3.8 3.9 4.0 4.1 4.2 4.3 3.3 E < 3.5 3.8 3.9 4.0 4.0 4.2 4.3 3.5 E < 3.7 3.7 3.8 3.9 4.0 4.1 4.2 3.7 E < 3.9 3.7 3.8 3.8 3.9 4.0 4.2 3.9 E < 4.1 3.6 3.7 3.8 3.9 4.0 4.1 4.1 E < 4.3 3.6 3.7 3.8 3.8 3.9 4.0 4.3 E < 4.5 3.5 3.6 3.7 3.8 3.9 4.0 4.5 E < 4.7 3.5 3.6 3.7 3.8 3.9 3.9 4.7 E < 4.9 3.5 3.5 3.6 3.7 3.8 3.9 E 4.9 3.4 3.5 3.6 3.7 3.8 3.9
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-110 Amendment No. 9 Table B2-32 Loading Table for PWR Fuel - 1710 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 57< B 58< B 59< B 58 59 60 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 4.4 4.6 3.3 E < 3.5 4.4 4.5 4.6 3.5 E < 3.7 4.3 4.4 4.5 3.7 E < 3.9 4.3 4.4 4.5 3.9 E < 4.1 4.2 4.3 4.4 4.1 E < 4.3 4.1 4.2 4.3 4.3 E < 4.5 4.1 4.2 4.3 4.5 E < 4.7 4.0 4.1 4.2 4.7 E < 4.9 4.0 4.1 4.2 E 4.9 3.9 4.0 4.1
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-111 Amendment No. 9 Table B2-33 Loading Table for PWR Fuel - 788 W/Assembly - WE 14x14 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 45< B 46< B 47< B 48< B 49< B 50< B 46 47 48 49 50 51 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 9.0 9.7 10.4 11.2 2.9 E < 3.1 8.9 9.5 10.1 10.9 11.4 12.2 3.1 E < 3.3 8.7 9.2 9.9 10.6 11.1 11.9 3.3 E < 3.5 8.5 9.0 9.7 10.3 10.9 11.6 3.5 E < 3.7 8.4 8.9 9.5 10.1 10.6 11.4 3.7 E < 3.9 8.2 8.7 9.3 9.9 10.4 11.1 3.9 E < 4.1 8.1 8.6 9.1 9.7 10.2 10.9 4.1 E < 4.3 8.0 8.5 9.0 9.5 10.0 10.7 4.3 E < 4.5 7.9 8.4 8.8 9.4 9.8 10.5 4.5 E < 4.7 7.8 8.2 8.7 9.3 9.7 10.3 4.7 E < 4.9 7.7 8.1 8.6 9.1 9.5 10.2 E 4.9 7.6 8.0 8.5 9.0 9.4 10.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-112 Amendment No. 9 Table B2-33 Loading Table for PWR Fuel - 788 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 51< B 52< B 53< B 54< B 55< B 56< B 52 53 54 55 56 57 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 13.1 14.0 15.0 3.1 E < 3.3 12.8 13.6 14.6 15.6 16.6 17.7 3.3 E < 3.5 12.4 13.3 14.2 15.3 16.2 17.3 3.5 E < 3.7 12.1 13.0 13.9 14.9 15.9 16.9 3.7 E < 3.9 11.9 13.0 13.6 14.6 15.5 16.5 3.9 E < 4.1 11.6 12.5 13.3 14.2 15.2 16.2 4.1 E < 4.3 11.4 12.2 13.1 13.9 14.9 15.9 4.3 E < 4.5 11.3 11.9 12.8 13.7 14.7 15.6 4.5 E < 4.7 11.1 11.8 12.6 13.5 14.4 15.3 4.7 E < 4.9 10.9 11.6 12.4 13.3 14.1 15.1 E 4.9 10.7 11.5 12.6 13.1 13.9 14.8
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-113 Amendment No. 9 Table B2-33 Loading Table for PWR Fuel - 788 W/Assembly - WE 14x14 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
WE 14x14 Assembly Average Burnup (B) GWd/MTU 57< B 58< B 59< B 58 59 60 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 18.7 19.7 3.3 E < 3.5 18.2 19.3 20.4 3.5 E < 3.7 17.9 18.9 19.9 3.7 E < 3.9 17.5 18.6 19.6 3.9 E < 4.1 17.2 18.2 19.2 4.1 E < 4.3 16.9 17.9 18.9 4.3 E < 4.5 16.6 17.6 18.6 4.5 E < 4.7 16.3 17.3 18.3 4.7 E < 4.9 16.0 17.0 18.0 E 4.9 15.8 16.8 17.8
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-114 Amendment No. 9 Table B2-34 Loading Table for PWR Fuel - 513 W/Assembly - CE 16x16 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU B 10 10< B 15< B 20< B 25< B 30< B 15 20 25 30 32.5 1.3 E < 1.5 4.0 1.5 E < 1.7 4.0 4.0 1.7 E < 1.9 4.0 4.0 4.9 1.9 E < 2.1 4.0 4.0 4.8 6.1 2.1 E < 2.3 4.0 4.0 4.8 6.0 8.2 10.0 2.3 E < 2.5 4.0 4.0 4.7 6.0 8.1 9.9 2.5 E < 2.7 4.0 4.0 4.7 6.0 8.1 9.8 2.7 E < 2.9 4.0 4.0 4.7 5.9 8.0 9.7 2.9 E < 3.1 4.0 4.0 4.6 5.9 7.9 9.6 3.1 E < 3.3 4.0 4.0 4.6 5.9 7.9 9.5 3.3 E < 3.5 4.0 4.0 4.6 5.8 7.9 9.4 3.5 E < 3.7 4.0 4.0 4.6 5.8 7.8 9.4 3.7 E < 3.9 4.0 4.0 4.5 5.8 7.8 9.3 3.9 E < 4.1 4.0 4.0 4.5 5.8 7.7 9.2 4.1 E < 4.3 4.0 4.0 4.5 5.8 7.7 9.2 4.3 E < 4.5 4.0 4.0 4.5 5.7 7.7 9.2 4.5 E < 4.7 4.0 4.0 4.5 5.7 7.6 9.1 4.7 E < 4.9 4.0 4.0 4.5 5.7 7.6 9.1 E 4.9 4.0 4.0 4.5 5.7 7.6 9.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-115 Amendment No. 9 Table B2-34 Loading Table for PWR Fuel - 513 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 32.5< B 35< B 37.5< B 40< B 41< B 42< B 35 37.5 40 41 42 43 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 12.5 15.8 2.5 E < 2.7 12.3 15.6 19.2 20.7 22.2 23.7 2.7 E < 2.9 12.1 15.4 19.0 20.5 22.0 23.4 2.9 E < 3.1 12.0 15.2 18.8 20.2 21.7 23.2 3.1 E < 3.3 11.9 15.0 18.5 19.9 21.5 23.0 3.3 E < 3.5 11.8 14.8 18.4 19.8 21.3 22.8 3.5 E < 3.7 11.7 14.7 18.2 19.7 21.1 22.5 3.7 E < 3.9 11.7 14.6 18.0 19.5 20.9 22.3 3.9 E < 4.1 11.6 14.5 17.9 19.3 20.8 22.2 4.1 E < 4.3 11.5 14.4 17.8 19.2 20.7 22.1 4.3 E < 4.5 11.4 14.3 17.7 19.1 20.5 21.9 4.5 E < 4.7 11.4 14.3 17.6 19.0 20.4 21.8 4.7 E < 4.9 11.4 14.2 17.5 18.9 20.3 21.7 E 4.9 11.3 14.1 17.4 18.8 20.2 21.6
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-116 Amendment No. 9 Table B2-34 Loading Table for PWR Fuel - 513 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 43< B 44< B 44 45 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 25.1 2.7 E < 2.9 24.8 26.3 2.9 E < 3.1 24.6 26.1 3.1 E < 3.3 24.4 25.8 3.3 E < 3.5 24.2 25.6 3.5 E < 3.7 24.0 25.4 3.7 E < 3.9 23.8 25.3 3.9 E < 4.1 23.7 25.0 4.1 E < 4.3 23.6 24.9 4.3 E < 4.5 23.4 24.8 4.5 E < 4.7 23.2 24.6 4.7 E < 4.9 23.1 24.5 E 4.9 23.0 24.4
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-117 Amendment No. 9 Table B2-35 Loading Table for PWR Fuel - 1300 W/Assembly - CE 16x16 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU B 10 10< B 15< B 20< B 25< B 30< B 15 20 25 30 32.5 1.3 E < 1.5 4.0 1.5 E < 1.7 4.0 4.0 1.7 E < 1.9 4.0 4.0 4.0 1.9 E < 2.1 4.0 4.0 4.0 4.0 2.1 E < 2.3 4.0 4.0 4.0 4.0 4.0 4.0 2.3 E < 2.5 4.0 4.0 4.0 4.0 4.0 4.0 2.5 E < 2.7 4.0 4.0 4.0 4.0 4.0 4.0 2.7 E < 2.9 4.0 4.0 4.0 4.0 4.0 4.0 2.9 E < 3.1 4.0 4.0 4.0 4.0 4.0 4.0 3.1 E < 3.3 4.0 4.0 4.0 4.0 4.0 4.0 3.3 E < 3.5 4.0 4.0 4.0 4.0 4.0 4.0 3.5 E < 3.7 4.0 4.0 4.0 4.0 4.0 4.0 3.7 E < 3.9 4.0 4.0 4.0 4.0 4.0 4.0 3.9 E < 4.1 4.0 4.0 4.0 4.0 4.0 4.0 4.1 E < 4.3 4.0 4.0 4.0 4.0 4.0 4.0 4.3 E < 4.5 4.0 4.0 4.0 4.0 4.0 4.0 4.5 E < 4.7 4.0 4.0 4.0 4.0 4.0 4.0 4.7 E < 4.9 4.0 4.0 4.0 4.0 4.0 4.0 E 4.9 4.0 4.0 4.0 4.0 4.0 4.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-118 Amendment No. 9 Table B2-35 Loading Table for PWR Fuel - 1300 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 32.5< B 35< B 37.5< B 40< B 41< B 42< B 35 37.5 40 41 42 43 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 4.0 4.0 2.5 E < 2.7 4.0 4.0 4.1 4.2 4.3 4.5 2.7 E < 2.9 4.0 4.0 4.1 4.2 4.3 4.4 2.9 E < 3.1 4.0 4.0 4.0 4.1 4.2 4.4 3.1 E < 3.3 4.0 4.0 4.0 4.1 4.2 4.3 3.3 E < 3.5 4.0 4.0 4.0 4.0 4.1 4.3 3.5 E < 3.7 4.0 4.0 4.0 4.0 4.1 4.2 3.7 E < 3.9 4.0 4.0 4.0 4.0 4.0 4.2 3.9 E < 4.1 4.0 4.0 4.0 4.0 4.0 4.1 4.1 E < 4.3 4.0 4.0 4.0 4.0 4.0 4.1 4.3 E < 4.5 4.0 4.0 4.0 4.0 4.0 4.0 4.5 E < 4.7 4.0 4.0 4.0 4.0 4.0 4.0 4.7 E < 4.9 4.0 4.0 4.0 4.0 4.0 4.0 E 4.9 4.0 4.0 4.0 4.0 4.0 4.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-119 Amendment No. 9 Table B2-35 Loading Table for PWR Fuel - 1300 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 43< B 44< B 44 45 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 4.6 2.7 E < 2.9 4.5 4.7 2.9 E < 3.1 4.5 4.6 3.1 E < 3.3 4.4 4.5 3.3 E < 3.5 4.4 4.5 3.5 E < 3.7 4.3 4.4 3.7 E < 3.9 4.3 4.4 3.9 E < 4.1 4.2 4.3 4.1 E < 4.3 4.2 4.3 4.3 E < 4.5 4.2 4.3 4.5 E < 4.7 4.1 4.2 4.7 E < 4.9 4.1 4.2 E 4.9 4.0 4.2
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-120 Amendment No. 9 Table B2-36 Loading Table for PWR Fuel - 1800 W/Assembly - CE 16x16 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU B 10 10< B 15< B 20< B 25< B 30< B 15 20 25 30 32.5 1.3 E < 1.5 4.0 1.5 E < 1.7 4.0 4.0 1.7 E < 1.9 4.0 4.0 4.0 1.9 E < 2.1 4.0 4.0 4.0 4.0 2.1 E < 2.3 4.0 4.0 4.0 4.0 4.0 4.0 2.3 E < 2.5 4.0 4.0 4.0 4.0 4.0 4.0 2.5 E < 2.7 4.0 4.0 4.0 4.0 4.0 4.0 2.7 E < 2.9 4.0 4.0 4.0 4.0 4.0 4.0 2.9 E < 3.1 4.0 4.0 4.0 4.0 4.0 4.0 3.1 E < 3.3 4.0 4.0 4.0 4.0 4.0 4.0 3.3 E < 3.5 4.0 4.0 4.0 4.0 4.0 4.0 3.5 E < 3.7 4.0 4.0 4.0 4.0 4.0 4.0 3.7 E < 3.9 4.0 4.0 4.0 4.0 4.0 4.0 3.9 E < 4.1 4.0 4.0 4.0 4.0 4.0 4.0 4.1 E < 4.3 4.0 4.0 4.0 4.0 4.0 4.0 4.3 E < 4.5 4.0 4.0 4.0 4.0 4.0 4.0 4.5 E < 4.7 4.0 4.0 4.0 4.0 4.0 4.0 4.7 E < 4.9 4.0 4.0 4.0 4.0 4.0 4.0 E 4.9 4.0 4.0 4.0 4.0 4.0 4.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-121 Amendment No. 9 Table B2-36 Loading Table for PWR Fuel - 1800 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 32.5< B 35< B 37.5< B 40< B 41< B 42< B 35 37.5 40 41 42 43 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 4.0 4.0 2.5 E < 2.7 4.0 4.0 4.0 4.0 4.0 4.0 2.7 E < 2.9 4.0 4.0 4.0 4.0 4.0 4.0 2.9 E < 3.1 4.0 4.0 4.0 4.0 4.0 4.0 3.1 E < 3.3 4.0 4.0 4.0 4.0 4.0 4.0 3.3 E < 3.5 4.0 4.0 4.0 4.0 4.0 4.0 3.5 E < 3.7 4.0 4.0 4.0 4.0 4.0 4.0 3.7 E < 3.9 4.0 4.0 4.0 4.0 4.0 4.0 3.9 E < 4.1 4.0 4.0 4.0 4.0 4.0 4.0 4.1 E < 4.3 4.0 4.0 4.0 4.0 4.0 4.0 4.3 E < 4.5 4.0 4.0 4.0 4.0 4.0 4.0 4.5 E < 4.7 4.0 4.0 4.0 4.0 4.0 4.0 4.7 E < 4.9 4.0 4.0 4.0 4.0 4.0 4.0 E 4.9 4.0 4.0 4.0 4.0 4.0 4.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-122 Amendment No. 9 Table B2-36 Loading Table for PWR Fuel - 1800 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 43< B 44< B 44 45 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 4.0 2.7 E < 2.9 4.0 4.0 2.9 E < 3.1 4.0 4.0 3.1 E < 3.3 4.0 4.0 3.3 E < 3.5 4.0 4.0 3.5 E < 3.7 4.0 4.0 3.7 E < 3.9 4.0 4.0 3.9 E < 4.1 4.0 4.0 4.1 E < 4.3 4.0 4.0 4.3 E < 4.5 4.0 4.0 4.5 E < 4.7 4.0 4.0 4.7 E < 4.9 4.0 4.0 E 4.9 4.0 4.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-123 Amendment No. 9 Table B2-37 Loading Table for PWR Fuel - 830 W/Assembly - CE 16x16 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU B 10 10< B 15< B 20< B 25< B 30< B 15 20 25 30 32.5 1.3 E < 1.5 4.0 1.5 E < 1.7 4.0 4.0 1.7 E < 1.9 4.0 4.0 4.0 1.9 E < 2.1 4.0 4.0 4.0 4.0 2.1 E < 2.3 4.0 4.0 4.0 4.0 4.7 5.0 2.3 E < 2.5 4.0 4.0 4.0 4.0 4.6 5.0 2.5 E < 2.7 4.0 4.0 4.0 4.0 4.6 4.9 2.7 E < 2.9 4.0 4.0 4.0 4.0 4.5 4.9 2.9 E < 3.1 4.0 4.0 4.0 4.0 4.5 4.8 3.1 E < 3.3 4.0 4.0 4.0 4.0 4.4 4.8 3.3 E < 3.5 4.0 4.0 4.0 4.0 4.4 4.7 3.5 E < 3.7 4.0 4.0 4.0 4.0 4.4 4.7 3.7 E < 3.9 4.0 4.0 4.0 4.0 4.4 4.7 3.9 E < 4.1 4.0 4.0 4.0 4.0 4.3 4.6 4.1 E < 4.3 4.0 4.0 4.0 4.0 4.3 4.6 4.3 E < 4.5 4.0 4.0 4.0 4.0 4.3 4.6 4.5 E < 4.7 4.0 4.0 4.0 4.0 4.3 4.5 4.7 E < 4.9 4.0 4.0 4.0 4.0 4.2 4.5 E 4.9 4.0 4.0 4.0 4.0 4.2 4.5
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-124 Amendment No. 9 Table B2-37 Loading Table for PWR Fuel - 830 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 32.5< B 35< B 37.5< B 40< B 41< B 42< B 35 37.5 40 41 42 43 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 5.5 6.0 2.5 E < 2.7 5.4 6.0 6.7 7.0 7.4 7.8 2.7 E < 2.9 5.4 5.9 6.6 6.9 7.2 7.7 2.9 E < 3.1 5.3 5.8 6.5 6.8 7.1 7.5 3.1 E < 3.3 5.2 5.8 6.4 6.7 7.0 7.4 3.3 E < 3.5 5.2 5.7 6.3 6.6 6.9 7.3 3.5 E < 3.7 5.1 5.7 6.3 6.6 6.8 7.2 3.7 E < 3.9 5.1 5.6 6.2 6.5 6.8 7.1 3.9 E < 4.1 5.0 5.6 6.1 6.4 6.7 7.0 4.1 E < 4.3 5.0 5.5 6.0 6.4 6.7 6.9 4.3 E < 4.5 5.0 5.5 6.0 6.3 6.6 6.9 4.5 E < 4.7 4.9 5.5 6.0 6.2 6.5 6.8 4.7 E < 4.9 4.9 5.4 5.9 6.2 6.5 6.8 E 4.9 4.9 5.4 5.9 6.1 6.4 6.7
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-125 Amendment No. 9 Table B2-37 Loading Table for PWR Fuel - 830 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 43< B 44< B 44 45 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 8.2 2.7 E < 2.9 8.0 8.6 2.9 E < 3.1 7.9 8.4 3.1 E < 3.3 7.8 8.2 3.3 E < 3.5 7.7 8.1 3.5 E < 3.7 7.6 8.0 3.7 E < 3.9 7.5 7.9 3.9 E < 4.1 7.4 7.8 4.1 E < 4.3 7.3 7.7 4.3 E < 4.5 7.2 7.6 4.5 E < 4.7 7.1 7.5 4.7 E < 4.9 7.0 7.4 E 4.9 7.0 7.4
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-126 Amendment No. 9 Note: For fuel assembly average burnup greater than 45 GWd/MTU, cool time tables have been revised to account for a 5% margin in heat load.
Table B2-38 Loading Table for PWR Fuel - 487 W/Assembly - CE 16x16 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 45< B 46< B 47< B 48< B 49< B 50< B 46 47 48 49 50 51 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 30.4 31.8 33.2 34.5 2.9 E < 3.1 30.1 31.6 32.9 34.3 35.5 36.8 3.1 E < 3.3 30.0 31.4 32.7 34.1 35.4 36.7 3.3 E < 3.5 29.8 31.2 32.6 33.9 35.2 36.6 3.5 E < 3.7 29.6 31.1 32.5 33.8 35.1 36.3 3.7 E < 3.9 29.4 30.8 32.3 33.6 34.9 36.3 3.9 E < 4.1 29.3 30.7 32.1 33.5 34.7 36.1 4.1 E < 4.3 29.1 30.6 32.0 33.4 34.6 35.9 4.3 E < 4.5 29.0 30.4 31.9 33.2 34.5 35.9 4.5 E < 4.7 28.9 30.2 31.7 33.1 34.4 35.7 4.7 E < 4.9 28.8 30.2 31.5 33.0 34.3 35.6 E 4.9 28.7 30.1 31.4 32.8 34.2 35.4
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-127 Amendment No. 9 Table B2-38 Loading Table for PWR Fuel - 487 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 51< B 52< B 53< B 54< B 55< B 56< B 52 53 54 55 56 57 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 38.1 39.3 40.5 3.1 E < 3.3 38.0 39.2 40.3 41.5 42.1 43.1 3.3 E < 3.5 37.8 39.1 40.2 41.4 41.9 43.1 3.5 E < 3.7 37.6 38.9 40.0 41.2 41.8 42.9 3.7 E < 3.9 37.6 38.7 39.9 41.1 41.7 42.8 3.9 E < 4.1 37.4 38.7 39.8 41.1 41.6 42.7 4.1 E < 4.3 37.3 38.6 39.7 40.9 41.4 42.6 4.3 E < 4.5 37.2 38.4 39.6 40.9 41.3 42.5 4.5 E < 4.7 37.0 38.2 39.4 40.8 41.2 42.4 4.7 E < 4.9 36.9 38.2 39.5 40.7 41.0 42.3 E 4.9 36.8 38.0 39.3 40.5 40.9 42.1
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-128 Amendment No. 9 Table B2-38 Loading Table for PWR Fuel - 487 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B)
GWd/MTU 57< B 58< B 59< B 58 59 60 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 44.3 45.3 3.3 E < 3.5 44.1 45.2 46.2 3.5 E < 3.7 44.0 45.1 46.2 3.7 E < 3.9 43.9 44.9 46.1 3.9 E < 4.1 43.8 44.9 46.0 4.1 E < 4.3 43.7 44.8 45.8 4.3 E < 4.5 43.7 44.7 45.8 4.5 E < 4.7 43.5 44.6 45.7 4.7 E < 4.9 43.4 44.5 45.7 E 4.9 43.4 44.4 45.6
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-129 Amendment No. 9 Table B2-39 Loading Table for PWR Fuel - 1235 W/Assembly - CE 16x16 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 45< B 46< B 47< B 48< B 49< B 50< B 46 47 48 49 50 51 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 5.1 5.3 5.5 5.7 2.9 E < 3.1 5.0 5.2 5.4 5.6 5.8 6.0 3.1 E < 3.3 4.9 5.1 5.3 5.5 5.7 5.9 3.3 E < 3.5 4.9 5.0 5.2 5.4 5.6 5.8 3.5 E < 3.7 4.8 5.0 5.1 5.3 5.5 5.7 3.7 E < 3.9 4.8 4.9 5.0 5.2 5.4 5.6 3.9 E < 4.1 4.7 4.9 5.0 5.2 5.4 5.6 4.1 E < 4.3 4.7 4.8 4.9 5.1 5.3 5.5 4.3 E < 4.5 4.6 4.8 4.9 5.0 5.2 5.4 4.5 E < 4.7 4.5 4.7 4.8 5.0 5.1 5.3 4.7 E < 4.9 4.5 4.7 4.8 4.9 5.1 5.3 E 4.9 4.5 4.6 4.8 4.9 5.0 5.2
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-130 Amendment No. 9 Table B2-39 Loading Table for PWR Fuel - 1235 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 51< B 52< B 53< B 54< B 55< B 56< B 52 53 54 55 56 57 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 6.2 6.5 6.7 3.1 E < 3.3 6.1 6.3 6.6 6.8 7.0 7.3 3.3 E < 3.5 6.0 6.2 6.5 6.7 6.9 7.1 3.5 E < 3.7 5.9 6.1 6.3 6.6 6.7 7.0 3.7 E < 3.9 5.8 6.0 6.2 6.5 6.6 6.9 3.9 E < 4.1 5.7 5.9 6.1 6.4 6.5 6.8 4.1 E < 4.3 5.7 5.8 6.0 6.3 6.4 6.7 4.3 E < 4.5 5.6 5.8 5.9 6.2 6.3 6.6 4.5 E < 4.7 5.5 5.7 5.9 6.0 6.2 6.4 4.7 E < 4.9 5.5 5.6 5.8 6.0 6.1 6.4 E 4.9 5.4 5.6 5.8 5.9 6.0 6.3
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-131 Amendment No. 9 Table B2-39 Loading Table for PWR Fuel - 1235 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B)
GWd/MTU 57< B 58< B 59< B 58 59 60 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 7.7 8.0 3.3 E < 3.5 7.5 7.8 8.2 3.5 E < 3.7 7.3 7.6 8.0 3.7 E < 3.9 7.1 7.5 7.8 3.9 E < 4.1 7.0 7.3 7.7 4.1 E < 4.3 6.9 7.2 7.5 4.3 E < 4.5 6.8 7.0 7.4 4.5 E < 4.7 6.7 6.9 7.2 4.7 E < 4.9 6.6 6.9 7.1 E 4.9 6.5 6.8 7.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-132 Amendment No. 9 Table B2-40 Loading Table for PWR Fuel - 1710 W/Assembly - CE 16x16 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 45< B 46< B 47< B 48< B 49< B 50< B 46 47 48 49 50 51 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 4.0 4.0 4.0 4.0 2.9 E < 3.1 4.0 4.0 4.0 4.0 4.0 4.1 3.1 E < 3.3 4.0 4.0 4.0 4.0 4.0 4.1 3.3 E < 3.5 4.0 4.0 4.0 4.0 4.0 4.0 3.5 E < 3.7 4.0 4.0 4.0 4.0 4.0 4.0 3.7 E < 3.9 4.0 4.0 4.0 4.0 4.0 4.0 3.9 E < 4.1 4.0 4.0 4.0 4.0 4.0 4.0 4.1 E < 4.3 4.0 4.0 4.0 4.0 4.0 4.0 4.3 E < 4.5 4.0 4.0 4.0 4.0 4.0 4.0 4.5 E < 4.7 4.0 4.0 4.0 4.0 4.0 4.0 4.7 E < 4.9 4.0 4.0 4.0 4.0 4.0 4.0 E 4.9 4.0 4.0 4.0 4.0 4.0 4.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-133 Amendment No. 9 Table B2-40 Loading Table for PWR Fuel - 1710 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 51< B 52< B 53< B 54< B 55< B 56< B 52 53 54 55 56 57 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 4.2 4.4 4.5 3.1 E < 3.3 4.2 4.3 4.4 4.5 4.6 4.7 3.3 E < 3.5 4.1 4.2 4.3 4.4 4.5 4.6 3.5 E < 3.7 4.0 4.2 4.3 4.4 4.5 4.6 3.7 E < 3.9 4.0 4.1 4.2 4.3 4.4 4.5 3.9 E < 4.1 4.0 4.1 4.2 4.3 4.3 4.4 4.1 E < 4.3 4.0 4.0 4.1 4.2 4.3 4.4 4.3 E < 4.5 4.0 4.0 4.1 4.2 4.2 4.3 4.5 E < 4.7 4.0 4.0 4.0 4.1 4.2 4.3 4.7 E < 4.9 4.0 4.0 4.0 4.0 4.1 4.2 E 4.9 4.0 4.0 4.0 4.0 4.1 4.2
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-134 Amendment No. 9 Table B2-40 Loading Table for PWR Fuel - 1710 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B)
GWd/MTU 57< B 58< B 59< B 58 59 60 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 4.9 5.0 3.3 E < 3.5 4.8 4.9 5.0 3.5 E < 3.7 4.7 4.8 5.0 3.7 E < 3.9 4.6 4.8 4.9 3.9 E < 4.1 4.5 4.7 4.8 4.1 E < 4.3 4.5 4.6 4.7 4.3 E < 4.5 4.4 4.5 4.7 4.5 E < 4.7 4.4 4.5 4.6 4.7 E < 4.9 4.3 4.4 4.5 E 4.9 4.3 4.4 4.5
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-135 Amendment No. 9 Table B2-41 Loading Table for PWR Fuel - 788 W/Assembly - CE 16x16 Fuel Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 45< B 46< B 47< B 48< B 49< B 50< B 46 47 48 49 50 51 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 10.2 11.0 11.8 12.7 2.9 E < 3.1 9.9 10.7 11.5 12.3 13.3 14.2 3.1 E < 3.3 9.8 10.5 11.2 12.0 12.9 13.9 3.3 E < 3.5 9.6 10.2 11.0 11.8 12.6 13.6 3.5 E < 3.7 9.4 10.0 10.8 11.6 12.4 13.3 3.7 E < 3.9 9.2 9.8 10.6 11.3 12.0 13.0 3.9 E < 4.1 9.1 9.7 10.4 11.1 11.9 12.8 4.1 E < 4.3 9.0 9.5 10.2 11.0 11.7 12.5 4.3 E < 4.5 8.9 9.4 10.0 10.8 11.5 12.3 4.5 E < 4.7 8.8 9.3 9.9 10.6 11.4 12.1 4.7 E < 4.9 8.7 9.2 9.8 10.5 11.2 12.0 E 4.9 8.6 9.1 9.7 10.3 11.1 11.8
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-136 Amendment No. 9 Table B2-41 Loading Table for PWR Fuel - 788 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B) GWd/MTU 51< B 52< B 53< B 54< B 55< B 56< B 52 53 54 55 56 57 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 15.2 16.3 17.4 3.1 E < 3.3 14.9 15.9 17.0 18.0 18.7 19.7 3.3 E < 3.5 14.6 15.6 16.6 17.7 18.2 19.3 3.5 E < 3.7 14.2 15.2 16.3 17.3 17.9 19.0 3.7 E < 3.9 13.9 14.9 15.9 17.0 17.5 18.6 3.9 E < 4.1 13.7 14.6 15.6 16.7 17.2 18.2 4.1 E < 4.3 13.4 14.3 15.4 16.4 16.9 18.0 4.3 E < 4.5 13.2 14.1 15.1 16.1 16.7 17.7 4.5 E < 4.7 13.0 13.9 14.9 15.8 16.4 17.4 4.7 E < 4.9 12.8 13.7 14.7 15.7 16.1 17.2 E 4.9 12.7 13.5 14.5 15.4 16.0 17.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-137 Amendment No. 9 Table B2-41 Loading Table for PWR Fuel - 788 W/Assembly - CE 16x16 Fuel (Continued)
Initial Assembly Avg. Enrichment wt % 235U (E)
Assembly Average Burnup (B)
GWd/MTU 57< B 58< B 59< B 58 59 60 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 2.3 E < 2.5 2.5 E < 2.7 2.7 E < 2.9 2.9 E < 3.1 3.1 E < 3.3 20.8 21.8 3.3 E < 3.5 20.4 21.4 22.5 3.5 E < 3.7 20.0 21.1 22.1 3.7 E < 3.9 19.7 20.7 21.7 3.9 E < 4.1 19.3 20.3 21.4 4.1 E < 4.3 19.0 20.0 21.1 4.3 E < 4.5 18.7 19.7 20.8 4.5 E < 4.7 18.4 19.5 20.5 4.7 E < 4.9 18.2 19.2 20.2 E 4.9 17.9 19.0 20.0
Appendix B Approved Contents Certificate of Compliance No. 1031 B2-138 Amendment No. 9 Table B2-42 Low SNF Assembly Average Burnup Enrichment Limits for CE 16x16 Fuel Loaded via the PMTC Max. Assembly Avg.
Burnup (MWd/MTU)
Min. Assembly Avg.
Initial Enrichment (wt% 235U)
Minimum Cool Time (yrs) 10,000 1.3 4.0 15,000 1.5 4.0 20,000 1.7 4.0 25,000 1.9 4.1 Table B2-43 Loading Table for CE 16x16 Fuel Loaded via the PMTC Initial Assembly Avg. Enrichment (wt% 235U)
Assembly Average Burnup (GWd/MTU) 25 < B 30 30 < B 35 35 < B 40 40 < B 45 45 < B 50 50 < B 55 55 < B 60 Minimum Cooling Time (years) 1.3 E < 1.5 1.5 E < 1.7 1.7 E < 1.9 1.9 E < 2.1 2.1 E < 2.3 4.8 2.3 E < 2.5 4.7 5.7 2.5 E < 2.7 4.7 5.6 6.9 2.7 E < 2.9 4.6 5.5 6.8 8.9 2.9 E < 3.1 4.6 5.5 6.7 8.8 14.0 3.1 E < 3.3 4.5 5.4 6.6 8.6 13.7 19.0 3.3 E < 3.5 4.5 5.3 6.6 8.5 13.4 18.7 23.5 3.5 E < 3.7 4.5 5.3 6.5 8.3 13.1 18.2 23.1 3.7 E < 3.9 4.4 5.2 6.4 8.2 12.9 17.9 22.7 3.9 E < 4.1 4.4 5.2 6.3 8.1 12.6 17.7 22.4 4.1 E < 4.3 4.4 5.2 6.3 8.0 12.4 17.4 22.1 4.3 E < 4.5 4.4 5.1 6.2 7.9 12.2 17.1 21.8 4.5 E < 4.7 4.3 5.1 6.2 7.8 12.0 16.8 21.5 4.7 E < 4.9 4.3 5.0 6.1 7.8 11.9 16.6 21.3 E 4.9 4.3 5.0 6.1 7.7 11.8 16.4 21.1 The minimum cool times for heat loads of 811 W/assy for assembly average burnups less than 45 GWd/MTU and heat loads of 770 W/Assy for burnups greater than 45 GWd/MTU