ML20160A043
| ML20160A043 | |
| Person / Time | |
|---|---|
| Site: | Nine Mile Point |
| Issue date: | 06/11/2020 |
| From: | Marshall M Plant Licensing Branch 1 |
| To: | Bryan Hanson Exelon Generation Co, Exelon Nuclear |
| Marshall M, NRR/DORL/LPL, 415-2871 | |
| References | |
| EPID L 2019-LLA-0115 | |
| Download: ML20160A043 (4) | |
Text
June 11, 2020 LICENSEE:
Exelon Generation Company, LLC FACILITY:
Nine Mile Point Nuclear Station, Unit 2
SUBJECT:
SUMMARY
OF APRIL 9, 2020, MEETING WITH EXELON GENERATION COMPANY, LLC REGARDING LICENSE AMENDMENT REQUEST TO CHANGE ALLOWABLE MAIN STEAM ISOLATION VALVE LEAK RATES AT NINE MILE POINT NUCLEAR STATION, UNIT 2 (EPID L-2019-LLA-0115)
On April 9, 2020, a public webinar was held between the U.S. Nuclear Regulatory Commission (NRC) and representatives of Exelon Generation Company, LLC (Exelon, the licensee). The purpose of the meeting was for Exelon to discuss planned changes to parts of the methodology described in the Nine Mile Point Nuclear Station (Nine Mile Point), Unit 2, main steam isolation valve license amendment request (LAR). The meeting notice and agenda, dated March 26, 2020, are available in the Agencywide Documents Access and Management System (ADAMS) at Accession No. ML20099A123. A copy of the LAR is available in ADAMS at Accession No. ML19151A537. A list of attendees is enclosed.
The licensee presented information (ADAMS Accession No. ML20098D508) on changes that it planned to make to the methodology and calculation supporting the LAR involving elemental iodine removal. The licensee stated the intent of the changes was to make the methodology described in the LAR more consistent with the current licensing basis for Nine Mile Point, Unit 2.
Exelon stated that it is making the changes in lieu of responding to the sixth question included in a request for additional information (RAI) the NRC issued to the licensee on February 14, 2020 (ADAMS Accession No. ML20045E358). The staff pointed out to the licensee that the sixth question concerned both aerosols and elementals and that aerosols would need to be addressed in the licensees response the RAI. The staff asked the licensee if it planned to remove references to the Metcalf model as part of the changes. The licensee stated that it did not plan to remove the reference. The changes would be included in the RAI response that was to be provided to the NRC by May 14, 2020.
No members of the public were in attendance except for representatives from the State of New York. No public meeting feedback forms were received. Please direct any inquiries to me at 301-415-2871 or Michael.Marshall@nrc.gov.
/RA/
Michael L. Marshall, Jr., Senior Project Manager Plant Licensing Branch I Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-410
Enclosure:
List of Attendees cc: Listserv
LIST OF ATTENDEES APRIL 9, 2020, MEETING WITH EXELON GENERATION COMPANY, LLC NINE MILE POINT NUCLEAR STATION, UNIT 2 LICENSE AMENDMENT REQUEST TO CHANGE ALLOWABLE MAIN STEAM ISOLATION VALVE LEAK RATES Name Organization Blumberg, Mark U.S. Nuclear Regulatory Commission (NRC)
Bowman, Greg NRC Clement, Richard NRC Danna, James NRC Dickson, Elijah NRC Goetz, Sujata NRC Hsueh, Kevin NRC Marshall, Michael NRC Meighan, Sean NRC Parillo, John NRC Stock, Gregory NRC Frymire, Bridget State of New York Peterson, Alyse State of New York Power, Cini State of New York Gudger, David Exelon Generation Company, LLC (Exelon)
Massari, John Exelon Reynolds, Ron Exelon Lafountain, Sam Enercon Services, Inc.
Morris, Joanne Enercon Services, Inc.
Enclosure
ML20160A043 OFFICE DORL/LPL1/PM DORL/LPL1/LA DORL/LPL1/BC DORL/LPL1/PM NAME MMarshall LRonewicz JDanna (JTobin for) MMarshall DATE 06/08/2020 06/10/2020 06/11/2020 06/11/2020