Raf:
--- 7 LOUIS 1ANA P O W E R & L I G H T ! WATEAFORD 3 SES e PO. 00X B e KLLONA, LA 70066-0751 mass May 4, 1988 W3A88-0043 A4.05 QA U.S. Nuclear Regulatory Commission ATTENTION: Document Control Desk Washington, D.C.
20555
SUBJECT:
Waterford 3 SES Docket No. 50-382 License No. NPF-38 Reporting of Special Report Attached is Special Eeport Number SR-88-004-00 for Waterford Steam Electric Statior. Unit 3.
This Special Report is submitted per 10CFR50.36(c)(2) and Technical Specifications 4.4.4.5 and 6.9.2.
i Very truly yours,
)Cw N.S. Carns Plant Manager - Nuclear NSC/WEM:rk Attachment ec R.D. Martin, NRC Resident Inspectors Office, INPO Records Center (J.T. Wheelock), E.L. Blake, W.M.
Stevenson, D.L. Wigginton P
8805100281 880504 PDR ADOCK 05000392 S
DCD s \\
"AN EQUAL OPPORTUNITY EMPLOYER"
e t
SPECIAL REPORT SR-88-004-00 Steam Generator Eddy Current Examination (2nd Refueling) l Inservice eddy current examination of the Steam Generator (S/G) tubing was completed at the Waterford Steam Electric Station Unit 3 on April 20, 1988.
This renort is submitted in accordance with Technical Specification (TS) l 4.4.4.5.a which requires reporting of the number of tubes plugged in each S/G l
within 15 days following the completion of inservice inspection of S/G tubes
(
pursuant to TS 6.9.2.
A followup report will be submitted in accordance with TS 4.4.4.5.b by April 20, 1989.
The total number of tubes which have been plugged in each steam generator are shown below:
S/G #1 S/G #2 Manufacturing /Preservice 6
20 l
Batwing (Preventive Plugging) 149 149 l
First Refueling 0
1 Second Refueling 3
2 l
TOTAL 158 172 l
l l
PLANT CONTACT L.L. Bass, Technical Support Supervisor, 504/467-279), Extension 327.
1
-