.a.

MAY 0 61987 U.S. NUCLEAR REGULATORY COMMISSION No.87-062 4-REGION I NOTICE OF SIGNIFICANT MEETING Licensee:

Baltimore Gas and Electric company l

Facility:

Calvert Cliffs Units 1 and 2 Docket No.:

50-317; 50-318 F

Time and Date:

10:00 a.m., May 13, 1987 Location:

Region I Office, King of Prussia, PA (Main Conference Room)

Purpose:

Enforcement Conference Regarding Environmental Qualification Program Deficiencies NRC Attendees:

W. F. Kane, Director, Division of Reactor Projects (DRP) a W. V. Johnston, Director, Division of Reactor Safety (DRS) l E. C. Wenzinger, Chief, Projects Branch No. 3, DRP l

J. P. Durr, Chief, Engineering Branch, DRS i

L. Tripp, Chief, Reactor Projects Section 3A, DRP 4

C. J. Anderson, Chief, Plant System Section, DRS i

i Licensee Attendees: J. A. Tiernan, Vice President, Nuclear Energy l

J. Lemons, Manager, Nuclear Operations e

J. Lippold, Manager, Nuclear Engineering Services Note:

Attendance by NRC personnel at this meeting should be made known by 4:00 p.m., May 8, 1987 via telephone call to D. Limroth, Region I, at FTS 8-488-1121 or 215-337-5121.

i Prepared JI

. E. Trtyp7 Chief, RPS 3A Distribution:

4 Victor Stello, Jr., Executive Director for Operations James M. Taylor, Deputy Executive Director for Regional Operations James G. Partlow, Director, Division of Reactor Inspection and Safeguards, NRR J. Lieberman, Director, Office of Enforcement l

T. E. Murley, Director, Office of Nuclear Reactor Regulation R. W. Starostecki, Associate Director of Inspection and Technical Assessment, NRR B. Boger, Assistant Director for Region I Reactor, NRR R. Capra, Director, Project Directorate I-1, NRR S. McNeil, Project Manager, PD I-1, NRR Public Document Room (PDR) j Local Public Document Room (LPDR) i i

i 8802290263 870506 PDR ADOCK 05000317 b

)

0 DCD

2 MAY 0 B 19W bec:

Regional Administrator Deputy Regional Administrator Division Directors Branch Chiefs Section Chiefs Public Affairs Officer Region I Receptionist C. White, 01 DRMA Files RI:D P RI: RP L m oth/meo r pp 5/5/87 0FFICIAL RECORD COPY