[p.08
UNITED STATES
'o .
NUCLEAR REGULATORY COMMISSION
[
REGION il
p
g
,. j
101 MARIETTA STREET, N.W..
4
ATLANTA. GEORGI A 30323
%...../
-Report Nos:
50-269/85-37, 50-270/85-37, and 50-287/85-37
-
Licensee:
Duke Power Company
422 South Church Street
Charlotte, N.C.
28242
Facility Name: Oconee Nuclear-Station
Docket Nos.: 50-269, 50-270, 50-287
License Nos.: DPR-38, DPR-47, and DPR-55
Inspection Conducted: October 8 - November 11, 1985
Inspectors:
W !d /-
511 <[
l'
'
J.
. Brya'nt
'f
Date Signed
itkd
u
M. K.-Sasser
Date' Signed
h
k
\\\\ ll W
L. P.
M ng
'f
Date 'Signe:1
-Approved by:
W
\\\\
}IA
H. C. Dance, Section Chief
Date Figned
-
Division of Reactor Projects
SUMMARY
Scope: This routine, unannounced inspection entailed 344 inspector hours on site
i n - the areas of - operations, surveillance, maintenance, followup of events,
startup from refueling, station modifications, onsite review committee, and
review of LERs, IFIs, and IE Bulletins.
Results: Of. the eight areas inspected, no items of noncompliance or deviations
-were identified in seven areas; one item of noncompliance was found in one area.
Failure to document the malfunction of valve 3LP-2 in the RC and SR0 log.
i
B511270251 851122
ADOCK 0500
9
G
{
,
I
.
.
REPORT DETAILS
1.
Licensee Employees
Persons Contacted
- M. S.~ Tuckman, Station Manager
- J. N. Pope, Superintendent of Operations
- R. T. Bond, Compliance Engineer-
_
- T. C. Matthews, Technical Specialist
- H. R. Lowery, Shift Operating Engineer
- W. E. Martin, Maintenance Services Engineer
- R. Ledford,- QA Surveillance Supervisor
- T. B. Owen, Superintendent of Maintenance
T. C. Barr, Superintendent of Technical Services
Other licensee employees contacted included technicians,- operators,
mechanics, security force members, and staff engineers.
Resident Inspectors
J. C. Bryant
- M. K. Sasser
'
L. P. King
- Attended exit interview.
,
-2.
Exit Interview
t.
~The inspection scope and findings were summarized on November 12, 1985, with
those persons indicated in paragraph I above. The licensee acknowledged the
violation discussed in paragraph 9.
The licensee did not identify as
proprietary any of the materials provided to or reviewed by the inspectors
during this inspection.
l
3.
Licensee Action on Previous Enforcement Matters
Not inspected.
4.
Unresolved Items
Unresolved items were not identified on this inspection.
5.
Plant Operations
The , inspectors reviewed plant operations throughout the reporting period to
verify conformance with regulatory requirements, Technical Specifications
(TS), and administrative controls.
Control room logs, shift turnover
[
records and equipment removal and restoration records were reviewed
I
-L
.
.
2
routinely.
Interviews were conducted with plant operations, maintenance,
chemistry, health physics and performance personnel.
Activities within the control rooms were monitored on an almost daily basis.
Inspections were conducted on day and on night shifts, during week days and
on weekends.
Some inspections were made during shift change in order to
evaluate shift turnover performance.
Actions observed were conducted as
required by:0perations Management Procedure 2-1.
The complement of licensed
personnel on .each shift inspected met or exceeded the requirements of TS.
Operators were responsive to plant annunciator alarms and were cognizant of
plant conditions.
Plant tours were taken throughout the reporting period on a routine basis.
The areas toured included the following:
Turbine Building
Auxiliary Building
Units 1,2, and 3 Electrical Equipment Rooms
Units 1,2, and 3 Cable Spreading Rooms
Station Yard Zone within the Protected Area
Unit 3 Reactor Building
Keowee Hydro Station
During the plant tours, ongoing activities, housekeeping, security,
equipment status, and radiation control practices were observed.
Unit 1 began the report period in cold shutdown mode for repair of steam
generator tube leaks. The unit had been shutdown on October 7.
During the
short outage, 3 tubes were plugged, one was a known leaker and the other two
were found to have less than the minimum required wall thickness.
On
October 18 the reactor was taken critical and power ircreased to 100%.
i
On October 20 the unit I reactor coolant system (RCS) leakage calculations
indicated greater than normal leakage, amounting to approximately 0.8
gallons per minute (gpm). Operations began running leakage calculations on
a more frequent basis and measures were taken to identify the source of the
leakage.
Several of the calculations- indicated leakage slightly greater
than the TS limit of 1 gpm unidentified; however, subsequent confirmatory
calculations would indicate slightly less than 1 gpm. The overall average
of the calculations was 0.75 gpm. Following several reactor building tours
as well as many RCS equipment manipulations, the source of the leakage was
determined to be the drain valve from the nitrogen decay tank in the RCS
letdown line.
After performing a safety evaluation the RCS leak rate
procedure was corrected to account for 0.75 gpm known leakage from the
nitrogen decay tank to the reactor building normal sump.
TSs allows
operations with up to 10 gpm identified leakage.
m
!
L
.
.
3
- The unit 1 leak remained stable until November 8 at which time an increase
on approximately 0.5 gpm was observed. The unit was shutdown on November 9
at 2:30 a.m., the decay tank drain valve was leak repaired, and the unit was
returned to criticality at 10:35 p.m. on the same day. At the end of the
report period the unit was operating at 97.5% power, slightly reduced due to
- problems in the main feedwater pump A control system.
Unit 2 began the report period operating at 100% power and continued at that
power level throughout the period.
Unit 3 began the report period at hot shutdown, continuing with unit-startup
activities following a refueling outage. The reactor was taken critical at
,
l
1:00 a.m. on October 8.
The unit was operated at 60% power until October 11
when power was increased to 100%.
During the unit 3 startup activities, several sources of RCS leakage had
been identified, including leakage past both reactor vessel 0-rings.
.Because of this leakage the licensee was planning to shut down the reactor
on or about October 18 for 0-ring replacement. However, on October 14 the
RCS leakage increased and, upon inspection, unidentified leakage was noted
coming from the 3A2 cavity.
Based on this new leakage and an increasing
trend the reactor was taken to hot shutdown. Further inspection identified
the leakage to be from a Graylock fitting on the cooling jacket of reactor
coolant pump 3A2.
The reactor was taken to cold shutdown, the reactor
vessel head removed, and 0-rings replaced. Other known sources of leakage
were repaired.
During the process of taking the reactor to cold shutdown, problems were
encountered in placing the LPI decay heat removal system in service, due to
the inability to open the loop isolation valve, 3LP-2, from the control room
hand switch. This problem is discussed in greater detail in paragraph 9.
Unit 3 was taken critical at.11:56 p.m. on October 24 following the RCS leak
repairs. During power escalation the reactor tripped from 10% power on loss
of both feedwater pumps. See paragraph 8 for further details. The reactor
was taken critical again at 11:56 p.m. on October 24 and power escalated to
100%. Unit 3 operated at 100% until 12:08 a.m. on November 7, when it began
-to shutdown due to an overheated bearing on the high pressure turbine. The
turbine was taken offline at 12:59 a.m. and the reactor was shut down at
4:20 a.m.
The bearing was replaced during the refueling outage and the
i
removed bearing has not yet been refurbished. The shutdown is anticipated
'
to last 5 to'14 days.
6.
Surveillance Testing
The surveillance tests listed below were reviewed and/or witnessed by the
inspectors to verify procedural and performance adequacy.
The completed
tests reviewed were examined for necessary test prerequisites, instructions,
~ acceptance criteria, technical content, authorization to begin work, data
collection,
independent verification where
required,
handling
of
deficiencies noted, and review of completed work.
l
j .-
I
-
2
<
~
.
.
4
Thef tests witnessed, in whole or in part, were inspected to determine that
approved procedures were available,
test equipment was calibrated,
prerequisites were cet. tests were conducted according to procedure, test
t
results were acceptaLse a.,d systems restoration was completed.
Surveillances witnessed in whole or in part are as follows:
OP/0/A/1105/09
CRD Patch Verification After Refueling on Head
Removal, Unit 3
IP/0/A/330/2D
CRD Patching Scheme and Functional Cabling, and
Patching Test, Unit 3
IP/3/A/0305/IE
RPS Channel "A" Temperature Calibration
PT/0/A/0150/22D
Individual Valve Functional Test, 3LP-1 and 3LP-2
PT/0/A/0400/15
SSF Auxiliary Service Water Pump Test
Surveillance tests reviewed were as follows:
Weekly PM of Keowee Turbine, Governor, and
Generator
Keowee Underground Feeder Interlock Test on ACB 3
and ACB 4
No violations or deviations were identified.
7.
Maintenance Activities
Maintenance activities were observed and/or reviewed during the reporting
period to verify that work was performed by qualified personnel and that
approved procedures in use adequately described work that was not within the
skill of the trade. Activities, procedures and work requests were examined
to veri fy proper authorization to begin work, provisions for fire,
cleanliness, and exposure control, proper return of equipment to service,
and that limiting conditions for operation were met.
Maintenance work witnessed in whole or in part was as follows:
WR 52861D
Verify Operability of 3LP-1
WR 25014B
3LP-2 Would Not Operate When Required to During
Shutdown.
I
Maintenance procedures reviewed are as follows:
WR 25032B
Disassembly and Maintenance on 3LP-17
WR 20077B
3LP-2 Failed to Open Electrically or Mechanically
.
.
5
3LP-2 Will Not Open Manually
No violations or deviations were identified.
8.
Unit-3 Reactor Trip
On_0ctober 24 at 1:28 a.m. Unit 3 tripped from 10% power due to a loss of
The trip was caused by a faulty auxiliary steam pressure
regulator. Operator' action in opening the main feedwater regulating valves
then caused the one feedwater pump which was operating to overspeed,
tripping the pump on high discharge pressure. Loss of both main feedwater
pumps resulted in an anticipatory reactor trip.
The emergency feedwater
pumps responded appropriately to provide feedwater to the steam generators.
Other systems responded as required.
There was no engineered safeguards
actuation.
Following repair of the faulty regulator the reactor was taken
critical and returned to power operations.
No-violations or deviations were identified.
9.
Operability of 3LP-2 (Low Pressure Injection Loop Isolation Valvo)
During a previous shutdown of Unit 3 on March 19, 1985 difficulty was
experienced in initiating decay heat removal because the loop isolation
valve, 3LP-2, failed to open on demand.
At that time, the licensee
committed to studying the problem to determine what action should be taken
to assure valve operability (IFI 50-287/85-07-01).
During the shutdown of Unit 3 on October 16, 1985, for repair of 0 ring
leakage, 3LP-2 once again failed to open on demand. Operations personnel,
in order to open the valve for decay heat removal, had to go to the valve
breaker and ' stick' the breaker. This involves using an insulated stick to
hold the contractor closed, bypassing the torque overloads so that increased
torque can be applied.
I&E personnel were on hand using an ammeter to
prevent overload and possible burnout of the motor operator.
This particular valve, on all three units, has a history of problems in
opening on demand. Several years ago the valve operators were changed to a
significantly smaller size after the stem of one of the valves was damaged
by the large operator installed at that time. The torque switch setting on
3LP-2 was then set at 300 foot pounds.
Based on the recent problems with
this valve, the licensee discussed the torque switch settings with the
manufacturer. The result is a new higher torque switch setting; the change
was effected on 3LP-2 and 3LP-1 during the outage beginning on October 16.
The - valves were successfully tested after these changes were made.
' Operability of these valves will continue to be monitored by the residents.
,
.
.
6
Following several incidents involving this valve on Units 1 and 2, the
station Onsite Review Group'(OSRG) recommended the installation of a bypass
line around the loop isolation valves, LP-1 and LP-2, in order to provide
assurance that decay heat removal could be initiated. This recommendation-
was the: same as that proposed by-Babcock & Wilcox for plants with single -
drop lines.
However, the licensee has not adopted this recommendation.
The ' resident inspectors became aware of recent problems with 3LP-2 on
October 17. Operations confirmed the problems in getting the valve to open.
- The inspectors could not find any discussion of these problems in either the
Reactor Operators' (RO) log or the Senior Reactor Operator's (SRO) log.
. Failure to log significant events prevents these problems from reaching
higher levels of management and also inhibits the reporting of these
problems by the appropriate station personnel.
Failure to log the
malfunction of 3LP-2 is an apparent violation of TS and Station Directives;
Violation - Failure to document the malfunction of 3LP-2 in the RO or SRO
log (287/85-37-01).
10 CFR 50.73 (vii) requires a Licensee Event Report (LER) to be issued in
any event where a single cause or condition caused at least one independent
train or channel to become inoperable in multiple systems or two independent
trains or channels to become inoperable in a single system designed to ..
(B) remove residual heat. The licensee will report the malfunction of 3LP-2
as an LER.
10.
Mispositioned Containment Isolation Valve, Unit 2
On October 8, while conducting - the quarterly containment verification
checklist on Unit 2, the Performance group found containment isolation valve
2LRT-38 in the open position.
This valve is required to be closed for
containment integrity. It was last verified closed prior to Unit 2 startup
by two separate procedures.
These procedures were Operations and
Performance checklists conducted on July 6 and July 7,1985, respectively.
After finding -the valve open, Performance pressurized the line to verify
that the inboard valve, 2LRT-39, was closed.
The valve is on a 1/4"
instrument line from the penetration room into the reactor building used for
leak . testing of penetrations.
In the penetration room the valve is
approximately 20 feet above the floor next to the reactor building wall.
The 1/4" line terminates in a quick disconnect which seals the line when
disconnected.
Therefore even though 2LRT-38 was open, the line was sealed.
The residents reviewed licensee actions and procedures involved to verify
that there was no open line into containment.
The Onsite Review Committee
(OSRG) is investigating this incident.
This mispositioned valve is a
violation but will not be cited since it meets the NRC enforcement guidance
of licensee identified violations.
The residents will continue to follow
this situation.
This will be listed as
inspector followup item
270/85-37-02; mispositioned containment isolation valve.
-
-
-
m
.
.
7
- ll.
Keowee Hydro Station Inspection
On October 9,1985, the inspectors toured and inspected the Keowee hydro
station. The recently completed Keowee modification which installed new
batteries was inspected.
These batteries are required as backup for
instrumentation and control at Keowee hydro.
The battery installation
includes a
new seismic support structure.
The inspectors also reviewed
controlled copies of safety related procedures in addition to the last
weekly and monthly surveillances.
12. Verification of Surveillance Tests
'
The inspectors completed their review to determine that surveillance testing
required for Unit 3 prior to startup from the recent refueling outage had
been completed.
In general, there were fewer difficulties encountered
during this review than in a similar review for Unit 2 described in report
-270/85-12.
However, one problem was noted.
When reviewing the status of
procedures required by TS, it was noted that for one TS requirement, Table
4.1-1,
item 36, confusion existed between licensee groups as to the
procedure performed to satisfy the requirement. After some deliberation the
licensee determined that the procedure in question is a Chemistry Department
procedure. The inspectors agreed with this determination and reviewed its
status to enture compliance.
As discussed in report 270/85-12, the licensee is pursuing the revision of a
station ' directive to provide a detailed cross reference of procedures
performed for TS compliance.
This cross reference should provide an
accurate accounting for all station groups, management, and the NRC.
The
licensee has a target completion date of January, 1986 to complete this
revision. This will be listed as inspector followup item, IFI 287/85-37-03:
Station directive revision to cross reference technical specifications.
13.
Inspector Followup Items
(Closed) IFI 269/85-03-02
Verification of performance tests utilizing
installed instrumentation.
Performance Manual section 4.14, approved
March 18, 1985, ' describes the method to ensure that installed plant
instrumentation, used in determining safety related equipment operability,
has been calibrated within the required intervals and is evaluated when
found out of tolerance.
This item is closed.
(Closed) IFI 269,270,287/85-10-02 Modifications and training concerning
power loss.
The inspectors reviewed the additional operator training,
.
procedural revisions, and station modifications and have determined them to
be acceptable. This item is closed.
(Closed)
IFI
287/85-32-01
Additional
training on shutdown margin
calculations. An operations training package on performing the appropriate
shutdown margin calculations was completed on October 28, 1985.
The
resident inspector reviewed the package. This item is closed.
.
.
8
,
14.
Review of Licensee Event Reports
The inspectors reviewed nonroutine event reports to verify that report
details met license requirements, identified the cause of the event,
described corrective actions appropriate for the identified cause, and
adequately addressed the event and any generic implications.
In addition,
as appropriate, the inspectors examined operating and maintenance logs, and
records and internal investigation reports.
Personnel were interviewed to verify that the report accurately reflected
the circumstances of the event, that the corrective action had been taken or
responsibility assigned to assure completion, and that the event was
reviewed by the licensee, as stipulated in the TS.
The following event
'
reports were reviewed:
(Closed)
Pie gamma scanner rotated over spent fuel
assemblies.
This incident was reviewed and the inspector followup item
(269/84-23-01) closed in report 269/85-12.
This LER is closed.
(Closed)
Single failure in the Keowee Woodward Governor
System could prevent automatic actuation of emergency power due to design
deficiency. A design study was completed resulting in station modifications
under NSM 2189, completed in June 1985, to eliminate the design flaw. This
LER is closed.
(Closed) LER 269/83-05
Double isolation criteria was not met for the
standby shutdown facility makeup water pump due to design deficiency.
The
design has been corrected, valves installed, and drawings changed. This LER
is closed.
(Closed) LER 269/85-01
Failure of ES power supply.
The power supply was
lost due to a failed component in the circuitry.
The power supply was
l
replaced and electrolytic capacitors will be replaced in RPS and ESF power
supplies on all units.
This LER is closed.
15.
IE Bulletin Review
Response to IE Bulletins were reviewed and, where appropriate, inspected at
the site.
The following bulletins has been resolved.
(Closed) IE Bulletin 84-03 Refueling water cavity seal.
16.
Information Meeting with Local Officials (94600)
On October 30, 1985 the inspectors met with the County Administrator of
Pickens County at his office in Pickens, South Carolina. On November 4 the
inspectors met with the Oconee County Supervisor at his office in Walhalla,
The purpose of the meetings was to familiarize the county
l
officials with the resident inspectors and their duties; to explain the
!
mission of the NRC in general, to review lines of communication and to hear
any comments the officials might have.
l
.
,
_ _ .
___ _ _______________ ____________ _ ____ - _
_ _ _ .
.
.
9
In general, both men were satisfied with relationships with the licensee.
One of them expressed concern with communications with the Oconee site
during an Alert in April 1985. After the discussions with the official and
with Oconee emergency preparedness personnel, the inspectors believe the
problems have been corrected. The officials were encouraged to call the
inspectors for information, if needed, and they were provided with Regional
telephone numbers.
The inspectors visited the Public Document Room at the Oconee County Library
in Walhalla.
They were favorably impressed with the facilities, the
condition and storage of records, and the timeliness with which documents
were filed.
17.
Site Drill
On October 25 the inspectors participated in an emergency drill. The drill
was conducted with the Technical Support Center (TSC) and supporting groups
situated in the training center.
The simulated problem, a ruptured main
steam line, was programmed into the simulator which wa: manned by an
operating crew in refresher training.
The drill appeared to be an
improvement on those held in the past in that operator actions and
recommendations by the TSC could be acted upon by the simulator and produce
a more realistic exercise.
18. Onsite Review Group (403018)
The OSRG organizational charter was reviewed to determine the specific
duties of the OSRG. Seven procedures that discuss the various functions of
the OSRG were reviewed and an interview was held with the chairman to
discuss the OSRG duties. Of the three basic duties, two were verified as
being performed as required.
These are:
(1) Review and dissemination of
operating experience; and (2) Preparing incident reports.
The review and
dissemination of operating experience will be followed up to determine if
the individual groups are distributing the OSRG information to the proper
personnel.
The third duty; the review of routine in plant activities for the purpose of
identifying deficiencies and/or deviations in programs, management control,
and work practices is being evaluated.
The experience level of the OSRG
members was discussed with the chairman. The residents will followup with
the remainder of the evaluation in the next report.
19.
Facility Modifications (37701)
The inspectors began a review of selected test procedures performed during
checkout of the Standby Shutdown Facility (SSF) which was declared operable
in October, 1985. Tests reviewed to date are as follows:
TT/3/A/0400/08 SSF - RC Makeup Pump Integrated Test
TT/3/A/0400/09 Local Type C Leak Rate Test on Penetration 17
- -
.
_ _ _ _ _ _ _ _ - - _ _ _ _ _ _ _
o
.
10
TT/2/A/0400/07 SSF - RC Makeup Pump Flow Verification Test
TT/0/A/0400/12 SSF Diesel Generator Initial Load Test
TT/3/A/0400/10 SSF Transfer Control Switch
TT/0/A/0400/05 SSF Auxiliary Service Water Pump Test
TT/2/A/0400/08 SSF RC Makeup Pump Integrated Test
TT/1/A/0400/08 SSF RC Makeup Pump Integrated Test
TT/2/A/0400/07 SSF RC Makeup Pump Performance Test
The only data which the inspector questioned concerned the makeup system
pump output.
The test procedure gave an expected range of 23 to 27 gpm at
approximately 2000 psig.
In a test performed on June 21, 1985, at 1975
psig, the Unit 2 pump provided 24.5 gpm indicated flow and 25 gpm measured
flow.
In a test performed on November 23, 1984 the Unit 1 pump provided
24.25 gpm indicated at 2275 psig.
Design information provided to NRR had
listed 26 gpm output.
The licensee has discussed the lower delivery rate
with NRR and has stated that the delivered flow exceeds system requirements.
While discussing pump performance with licensee engineers, the inspector was
informed that the pumps will be modified to provide greater piston
displacement and increased flow with no loss of discharge pressure.
This
item will not be listed as a followup item since it is already open with
NRR.
Review of test procedures and data will continue in a subsequent inspection.
IE Bulletin 79-23 pointed out a potential diesel generator failure and
requested a response from licensees on certain circuitry questions and
requested a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> full load test. At the time the bulletin was issued,
Oconee had no emergency power diesels. The inspector has requested Duke to
verify that the SSF Diesel generator meets the requirements of Bulletin 79-23.
This information will be reviewed when received.
No violations or deviations were identified.
20. Main Steam Code Safety Valves
Delayed reseating of main steam safety valves has been discussed in several
reports during the past year, including 269/84-32, 85-01, and 85-07. Report
No. 269/85-07 described the program the licensee had instituted to rebuild
four of the valves on each refueling outage.
In addition to the scheduled
work, during the Unit I shutdown for steam generator tube leaks on
October 7-18, 1985, the licensee reworked code safety valves 2, 4, and 10,
Valves 2, 4, and 10 on Unit I had been the primary offenders on late
reseating. On the recent shutdown these valves were recut, lapped, and the
blowdown rings adjusted.
Valve No. 4 was found to have some gouges in a
bushing which could have caused the stem to hang up.
Future performance
will determine the success of the rework.
___________-__ - ______
-
~
.
.
11
21. Maintenance on 3LP-17, Low Pressure Injection (LPI) Valve
The inspectors reviewed in detail the maintenance package on valve 3LP-17,
the LPI discharge valve.
The inspectors were concerned about the leak
tightness of the valve because the completed procedure indicated that the
valve disc and seat had not been lapped in as is normally done.
Further
investigation revealed that, under the inservice inspection program, the
valve is not required to be leak tight. There are two check valves
protecting the LPI system against overpressure.
The inspectors reviewed with Maintenance Department management the work done
on the valve. Maintenance performed was extensive. Maintenance agreed that
the procedure did not reflect all the details of the maintenance but that it
was documented on the work request.
No violations or deviations were identified.