Text

_ _ _ _ _

,o-ee a

  1. R 17 BBS MEMORANDUM FOR:

D. M. Cr'itchfield, Assistant Director for Safety Assessment. DL FROM:

L. S. Rubenstein, Assistant Director e

for Core and Plant Systems DSI

SUBJECT:

STAFF EVALUATION OF GE TOPICAL REPORT NEDE-24011 (GESTAR)

AMENDMENT 8 Report

Title:

Compliance of General Electric Boiling Water Reactor Fuel Designs to Stability Licensing Criteria Report Number:

NEDE.24011, Amendment 8 Report Date:

September 1983 Responsible Branch:

Standardization and Special Projects Branch Project Manager:

Dave Moran Review Branch:

Core Performance Branch TACS Nos.:

49898/56516/53361 Review Status:

Complete The Core Performance Branch has completed the review of the General Electric topical report NEDE-24011 Amendment 8 and our evaluation is attached. We find the methods explained in this topical meet the stability criteria set forth in General Design Criteria 10 and 12 provided they are used within the bounds described in the staff position in Section 4.0 of our Safety Evaluation.

This SER includes the evaluation of NEDE-22277-P.1 which was enclosed in our memo of April 5, 1985. Since NEDE-22277-P-1 is referenced in NEDE-24011, this SER supersedes and is a replacement for " Staff Evaluation of GE Topical Report NEDE-22277.P-1," dated April 5,1985.

Original signed b)

L S.Rubenstein L. S. Rubenstein, Assistant Director for Core and Plant Systems, DSI

Enclosure:

As stated DISTRIBUTION:

cc:

R. Bernero Central Files C. Thomas CPB R/F D. Moran LRubenstein G. Thomas LPhillips W. Hodges RLobel B. Sheron -

DFieno GSchwenk e

Contact:

G. A.'S'chwenk, CPB:DSI X-29421 P VIOUS CONCURRENCE gggy g

,7, j tu n a,rn

vw :t,rp
D5

-r

CPS

....,f.... :. 0 51 s............:...........

lE**GSchwenk

  • LPhillipt erlinger :LHDe in :

-.g............:..........

E 23/15/85

3/15/85
4/ I4/85
4/ # 7/85 ICIAL RECORD COPY n