Text
l
jar 88Gu
URIT ED STATES
/,
.'.
NUCLEAR REGULATORY COMMISSION
-
'
{ C
.5
. < ,.j j
R EGloN IV
611 RY AN PLAZA DRIVE, SUITE 400
,
%...*.+,.,
,
,
i
MAR 3 I 1997
i
G. R. Horn, Senior Vice President
{
,
of Energy Supply
{
Nebraska Public Power District
141415th Street
Columbus, Nebraska 68601
,
SUBJECT: NRC INSPECTION REPORT 50-298/97-02 AND NOTICE OF VIOLATION
Dear Mr. Horn:
An NRC inspection was conducted on January 12 through February 22,1997, at your
Cooper Nuclear Station facility. The enclosed report presents the scope and results of that
inspection.
Based on the results of this inspection, the NRC has determined that two violations of NRC
requirements occurred. These violations are cited in the enclosed Notice of Violation
(Notice) and the circumstances surrounding the violations are described in detail in the
enclosed report. Please note that you are required to respond to this letter and should
,
follow the instructions specified in the enclosed Notice when preparing your response. The
NRC will use your response, in part, to determine whether further enforcement action is
necessary to ensure compliance with regulatory requirements.
The first violation identifies three examples of maintenance technicians failing to properly
implement a procedure. The second violation describes a failure to implement appropriate
corrective actions.
'
The NRC is concerned with the failure to properly implement a maintenance procedure
because procedural adherence has been an ongoing issue at Cooper Nuclear Station and
was discussed in the recent SALP report. Our concern with the failure to implement
appropriate corrective actions is that it indicates that some plant personnel still do not
understand the Problem Identification Report (PIR) process, even though plant management
has given it much emphasis this past year.
l
in accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter,
its enclosure (s), and your response will be placed in the NRC Public Document
Room (PDR). To the extent possible, your response should not include any personal
privacy, proprietary, or safeguards information so that it can be placed in the PDR without
redaction.
9704040059 970331
ADOCK 05000298
@ll.ERElll45REWX
G
____.__.___-.._.._.__._.____.____._.._.______m_.__~_._____..
,;- -
,
!
1
t-
< -
}
Nebraska Pubhc Power District
-2-
!
l
.
}
Should you have any questions concerning this inspection, we will be pleased to discuss
j
them with you.
i
Sincerely,
4
i
i
/
. _
- - -
1
W
i
T omas P. Gwynn, irector
Division of Reactor Projects
t.
l
Docket No.: 50-298
)
License No.: DPR-46
i
!
Enclosures:
j
1. Notica of Violation
i
2. NRC Inspection Report
i
50 298/97-02
i
i
I
Cc W/ enclosures:
!
John R. McPhail, General Counsel
!
Nebraska Public Power District
l
P.O. Box 499
Columbus, Nebraska 68602-0499
-
3
4-
P. D. Graham, Vice President of
l
Nuclear Energy
i
Nebraska Public Power District
l
P.O. Box 98
{
Brownville, Nebraska 68321
B. L. Houston, Nuclear Licensing
4
l
and Safety Manager
i
Nebraska Public Power District
P.O. Box 98
Brownville, Nebraska 68321
i
R. J. Singer, Manager-Nuclear
Midwest Power
907 Walnut Street
i
P.O. Box 657
Des Moines, Iowa 50303
.
4
\\
.
.
.
. .
. - -
__ _
-. -- .
.
s
.
.
Nebraska Public Power District
-3-
Mr. Ron Stoddard
Lincoln Electric System
11th and O Streets
Lincoln, Nebraska 68508
.
Randolph Wood, Director
l
Nebraska Department of Environmental
Quality
P.O. Box 98922
Lincoln, Nebraska 68509-8922
,
Chairman
1
Nemaha County Board of Commissioners
Nemaha County Courthouse
1824 N Street
Auburn, Nebraska 68305
'
Cheryl Rogers, LLRW Program Manager
Environmental Protection Section
Nebraska Department of Health
301 hntennial M:Ji, South
P.O. Bo t 95007
Lincoln, Nebraska 68509-5007
Dr. Mark B. Horton, M.S.P.H.
,
Director
Nebraska Department of Health
P.O. Box 950070
Lincoln, Nebraska 68509-5007
R. A. Kucera, Department Director
of Intergovernmental Cooperation
Department of Natural Resources
P.O. Box 176
Jefferson City, Missouri 65102
Kansas Radiation Control Program Director
l
'
!
i
,
4
_ . _
.__ . _ . - .
. _ _ _ _ _ _ _ _ . _ . .
_ _ _ _ _ _ _ _ .
.
. _ _ _ _ _ _ _ _ . . _ _ _ . _ _ _
-
i
.
4
?
'
MAR 31 1997
.
I
'
.
Nebraska Public Power District
-4-
'
l
!
,
E-Mail report to T. Boyce (THB)
E-Mail report to NRR Event Tracking System (IPAG)
,
E-Mail report to Document Control Desk (DOCDESK)
E-Mail report to Richard Correia (RPC)
l
,
'
E-Mail report to Ronald Frahm, Jr. (RKF)
bec to DCD (IE01)
bec distrib. by RIV:
,
Regional Administrator
Resident inspector
3
j
DRP Director
DRS-PSB
i
Branch Chief (DRP/C)
MIS System
Branch Chief (DRP/TSS)
RI V File
Project Engineer (DRP/C)
Leah Tremper (OC/LFDCB, MS: TWFN 9E10)
.
l
l
1
i
i
I
'
l
i
i
!
i
i
.
d
DOCUMENT NAME: R:\\ CNS\\CN702RP.MHM
<
]
To receive copy of document, indicate in box: "C" = Copy without enclosures
"E" = Copy with enclosures "N" = No copy
'
'
RIV: SRI l
AC:DRP/C
D;DRP
W
,
4
MHMillerg L
LAYandel6
TPGwynn f
4
3/b /97
- O
3/f4/97
/
3/$/97
\\l
V
FFICIAL RECORD COPY
g
,
4
.
_
-
s
,
fM 31 1997
Nebraska Public Power District
-4-
>
E-Mail report to T. Boyce (THB)
E-Mail report to NRR Event Tracking System (IPAS)
E-Mail report to Document Control Desk (DOCDESK)
E-Mail report to Richard Correia (RPC)
E-Mail report to Ronald Frahm, Jr. (RKF)
bec to DCD (IE01)
bcc distrib. by RIV:
Regional Administrator
Resident inspector
DRP Director
DRS-PSB
Branch Chief (DRP/C)
MIS System
j
Branch Chief (DRP/TSS)
RIV File
Project Engineer (DRP/C)
Leah Tremper (OC/LFDCB, MS: TWFN 9E10)
I
'
/
DOCUMENT NAME: R:\\_CNS\\CN702RP.MHM
To receive copy of document, indicate in box: "C" = Copy wahout enclosures
"E" = Copy wth enclosures "N" = No copy
RIV: SRI i
AC:DRP/$l
D:DRP
l p7
l
l
,
MHMillery b
LAYande Q
TPGwynn f
3/2i/97
'f
3/J(/97
l
3/31/97
V
V
FFICIAL RECORD COPY
\\