U. S. NUCLEAR REGULATORY COMMISSION
REGION III
Reports No. 50-315/8501S(DRSS); 50-316/85019(DRSS)
Docket Nos. 50-315; 50-316
Safeguards Group IV
Licensee: American Electric Power Service Corporation
Indiana and Michigan Electric Company
1 Riverside Plaza
Columbus, OH 43216
Facility Name:
Donald C. Cook Nuclear Power Plant, Units 1 and 2
Inspection At:
Donald C. Cook Site, Bridgman, MI
Inspection Conducted:
June 18 and 19, 1985
Date of Last Physical Security Inspection:
January 7-11, 1985
Type of Inspection:
Special Physical Protection
f
[// [
-
Inspector:
T. J. Madeda h
Physical Security Inspector
Dats
7/WI
Approved By:
.R.
reed, Chief
Safeguards Section
Date
Inspection Summary:
Inspection on June 18 and 19, 1985 (Report No. 50-315/85018(DRSS);
50-316/85019(DRSS))
Areas Inspected:
Included a review of two security events / incidents,
pertaining to vital area access control and one event pertaining to
reporting an incident to the NRC.
The inspection involved 13 inspector
hours by one NRC inspector.
Results:
Based on inspection findings, two apparent violations.were
identified.
1.
Access Control - Personnel:
Licensee failed to adequately control
access to a vital area such that on three occassions' barriers were
degraded and no compensatory measures were taken (Section 4).
2.
Records and Reports:
Licensee failed to notify the NRC of a
reportable physical security event (Section 3).
(Details - UNCLASSIFIED SAFEGUARDS.INFORMATION)
Encic:;ure contains
SAFEGUARDS INFORMATION
Upon separation this
8507150202 850710
page is Decontrolled
gDR
ADOCM 05000315
I