ML20128N122
| ML20128N122 | |
| Person / Time | |
|---|---|
| Site: | Millstone |
| Issue date: | 10/04/1996 |
| From: | Scace S NORTHEAST NUCLEAR ENERGY CO., NORTHEAST UTILITIES SERVICE CO. |
| To: | Dinoia M CONNECTICUT, STATE OF |
| Shared Package | |
| ML20128N126 | List: |
| References | |
| D10309, NUDOCS 9610160297 | |
| Download: ML20128N122 (3) | |
Text
u,) Northeast 107 seiden street, Berim, cT 06037 F Utilities System Northeut ceue. senw comp.ny P.o. Box 270 Hartford, CT 061410270 (203) 665-5000 October 4,1996 D10309 Ms. Michelle DiNoia Bureau of Water Management Department of Environmental Protection 79 Elm Street Hartford, CT 06106-5127
Reference:
Letter (D10112), D. B. Miller, Jr. to M. DiNoia, dated August 21,1996.
Dear Ms. DiNoia:
Millstone Station Reauest for Hydrazine. Ethanolamine and Boron Analysis Procedure Approval Enclosed are the hydrazine and ethanolamine (ETA) procedures for Millstone Station, as 1
discussed in the Referenced letter. Also attached are two procedures used for analysis of boron at Millstone Station. No pre-approved Environmental Protection Agency (EPA) methods exist for hydrazine or ETA. We are submitting these procedures for approval by the Commissioner of the Department of Emironmental Protection (DEP). Pursuant to RCSA Section 22a-430-3(7) and 40 CFR Section 136.4 this should be submitted by DEP to John DeVillars, Regional Administrator, Region 1, for EPA's review and approval. Attachment A provides the number and description of the procedures used at each of the units.
Please note that we have submitted three procedures for the analysis of hydrazine. The titration method is applicable for samples empected to contain higher hydrazine levels (>1000 ppb) while the spectrophotometric method is appropriate for samples expected to contain low levels (< 1000 ppb). The spectrophotometric method can be used on samples expected to contain > 1000 ppb hydrazine provided that sample dilution is performed prior to analysis; however, this step can reduce accuracy and sample processing efliciency. The ion chromatographic method measures low level concentrations of hydrazine, while simultaneously providing the ETA concentrations required under our existing permit.
g We are requesting approval of all three hydrazine methods. This will enable us to use the most appropriate method for expected hydrazine concentrations, permit limitations and potential for interferences in the sample.
9610160297 961004 PDR ADOCK 05000245
/NQ V
P PDR 063422 REY.194
Ms. Michelle DiNoia D10309/Page 2 October 4,1996 In most cases, the low range spectrophoton:etric or ion chromatographic methods will be used to determine hydrazine levels in process equipment and for environmental samples where concentrations below 1000 ppb might be anticipated. The high range titration method will be used to process samples where high levels of hydrazine might be expected (i.e., steam generator layup discharges).
Similarly, we are submitting two procedures for boron for your approval; one utilizes a titration method while the second is an inductively coupled plasma emission spectrophotometric method.
The two procedures provide ft:xibility to analyze the various process streams at Millstone.
Should you have any q;estions or comments regarding this information, please call Paul Jacobson at (860) 665-3617.
Very truly yours, Northeast Nuclear Energy Company m
CatL
~
ftephen E. Scac6
/
Acting Director, Nuclear Engineering Programs cc:
Mr. Michael J. Harder, Director Water Management Bureau, PERD Department of Environmental Protection 79 Elm Street Hartford, CT 06106-5127 NRC Document Control Desk Attachment
J
~
Ms. Michelle DiNoia D10309/ Attachment October 4,1996 ATTACHMENT A The following procedures and methods are attached:
Procedure Number:
Descriotion:
CP 807/2807/3807AR Hydrazine analysis using titration CP 807/2807/3807AP Hydrazine analysis using spectrophotometer CP 801/2801/3801Y Analysis procedure for ion chromatography
" Cation 1" Ethanolamine analysis using ion chromatography ETAMET Ethanolamine analysis using ion chromatography
" Cation 5" Hydrazine analysis using ion chromatography l
CP 807/2807/3807AA Boron analysis using autotitrator procedure CP 801/2801/3801 AJ Boron analysis using inductively coupled plasma emission spectrophotometer i
d
.)
a f
4 4
4