Submits Daily Highlight.Initial Leak Rate Calculations for Util Indicate RCS Leak Rate of 0.1 - 0.2 Gpm.Primary to Secondary Leakage Appears to Be 0.80 - 0.85 Gph
ML20126C100
Person / Time
Site: Crane Constellation icon.png
Issue date: 09/01/1983
From: Van Vliet J
Office of Nuclear Reactor Regulation
To: Carter J, Harold Denton, Eisenhut D
NRC
Shared Package
ML20126B295 List: ... further results
References
FOIA-84-897 NUDOCS 8506140312
Download: ML20126C100 (1)


Text

__

p'

  • c %'o, UNITED STATES h,

[

-7j NUCLEAR REGULATORY COMMISSION

.p

.,,e WASHINGTON, D. C. 20555 f

,1.,['*d,/

September 1, 1983 9

Docket No. 50 ZW MEMRANDUM FOR:

H. Denton T. Speis J. Carter R. Vollmer E. Case D. Eisenhut R. Mattson S. Varga 4

R. Purple H, Thompson D. Vassallo T Novak J. Sniezek J. Miller G. La1 WW W WP D. Crutchfield F,,,Mi r.n a saglia C. Heltenes THRU:

John F. Stolz, Chief, Operating Reactors Branch #4,.

Division of Licensing James A. 'VanVlia',p'roject fianager FROM:

t Operating Reactors Branch #4, Division of Licensing i

SUBJECT:

DAILY HIGHLIGHT TMI-1 STEAM GENERATOR LEAK RATES

=-

Initial leak rate calculations for TMI-1 at normal operating pressure indi-cate an RCS leak rate of 0.1 - 0.2 gallons per minute.

Primary to secondary leakage appears to be 0.80 - 0.85 gallons per hour. This is a small fraction of technical specification limits for primary to secondary leakage of 1 gal-lon per minute.

ms A. Va V Operating Reactors Eranchf4 Division of Licensing cc:

JStalz

'. ;nV11 et C W4 File

~~ % -- __

8506140312 850125 PDR FOIA DETJEN84-g97 PDR