ML20107L927
| ML20107L927 | |
| Person / Time | |
|---|---|
| Site: | Peach Bottom |
| Issue date: | 01/03/1996 |
| From: | PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC |
| To: | |
| Shared Package | |
| ML20107L903 | List: |
| References | |
| PROC-960103, NUDOCS 9604300086 | |
| Download: ML20107L927 (125) | |
Text
-.. -. _. _
, 3- - s
- l i
l Offsite Dose Calculation Manual Revision 9 t
Peach Bottom Atomic Power Station Units 2 and 3 l
l l
PECO Energy Company Docket Nos. 50-277 & 50-278 i
I 0
PORC Approval j
-PORC Chairman Date.
l 1
PORC Meeting # :
W~Ob1 I
l3 Date i
{
f-
"~
9604300086 960422 PDR ADOCK 05000277 R
- r ~s 7
Table of Contents I.
Purpose II.
Instrument Setpoints III.
Liquid Pathway Dose Calculations A.
Liquid Radwaste Release Flow Rate Determination B.
ODCMS 4.8.B.2.1 C.
ODCMS 4.8.B.4.1 IV.
Gaseous Pathway Dose Calculations A.
ODCMS 4.8.C.1.1 and 4.8.C.1.2 B.
ODCMS 4.8.C.2.1 C.
ODCMS 4.8.C.3.1 D.
ODCV.S 4.8.C.5.1 E.
Tec'.inical Requirements Manual Test Requirement (TR) 3.5.J V.
Nuclear Fuel Cycle Dose Assessment - 40 CFR 190 A.
ODCMS 4.8.D 1.1 and 4.8.D.1.2 VI.
Calender Year Dose Calculations A.
Unique Reporting Requirement ODCMS 3.10.3 VII.
Radiological Environmental Monitoring Program A.
ODCMS 4.8.E.1.1 and 4.8.E.1.2 VIII.
Bases Appendix A Radioactive Effluents Control Program
)
i i
,st~t Page 3 of 48, Rev. 9 1
l I.
Purpose l
l The purpose of the Offsite Dose Calculation Manual is to i
establish methodologies and procedures for calculating doses to individuals in areas at and beyond the SITE BOUNDARY due to radioactive effluents from Peach Bottom Atomic Power Station.
The results of these calculations are required to determine compliance with the requirements of Specification 5.5.4,
" Radioactive Effluent Controls Program" of Appendix A to Operating Licenses DPR-44 and DPR-56, " Technical Specifications for Peach Bottom Atomic Power Station Units No.
2 and 3".
The Radioactive Effluents Control Program is located in Appendix A of this Offsite Dose Calculation Manual and contains Offsite Dose Calculation Manual Specifications (ODCMS) and their associated Bases which implement the requirements of Technical Specification 5.5.4.
II.
Setooint Determination for Licuid & Gaseous Monitors II.A Licuid Radwaste Activity Monitor Setooint Each tank of radioactive waste is sampled prior to release.
A small liquid volume of this sample is analyzed for' gross gamma activity in a NaI well counter.
This NaI well counter activity is then converted to an equivalent liquid radwaste monitor reading.
[ Net CPM /ml (well) x Eff W/RW) +
CPS (R/W Monitor)
=
Background CPS Where:
liquid radwaste gross activity CPS (R/W Monitor)
=
monitor reading in CPS gross gamms activity for the Net CPM /ml (well)
=
radwaste sample tank (determined by the well counter]
conversion factor between well Eff W/RW
=
counter and liquid radwaste gross activity monitor (determined by calibrating both detectors with the same liquid radioactive source]
background reading of the liquid Background CPS
=
radwaste gross activity monitor in CPS l
Exceeding the expected response would indicate that an incorrect sample had been obtained for that release and the release is automatically stopped.
1
Page 4 of 48, Reye 0,,
i The alarm and trip pot setpoints for the liquid radwaste activity monitor are determined from a calibration curve for the alarm pot and trip pot.
The alarm pot setting includes a factor of 1.25 to allow for analysis error,. pot setting error, i
instrument error and calibration error.
The trip pot setting includes-a factor of 1.35 to allow for analysis error, pot setting error, instrument error and calibration error.
II.B Licuid Radwaste Release Flowrate Setooint Determination The trip pot setpoint for the liquid radwaste release flowrate
-is determined by multiplying the liquid radwaste flowrate (from Section III.A) by 1.2 and using this value on the appropriate calibration curve for the discharge flow meter to be used.
The~ Peach Bottom radwaste system has two flow monitors - high flow (5 to 300 gpm) and low flow (0.8 to 15 gpm).
The factor;of 1.2 allows for pot setting error and 4
instrument error.
The flow rate determination includes a margin of assurance which includes consideration of this error such that the instantaneous release limit of 10 CFR 20 is not exceeded.
II.C Setooint Determination for Gaseous Radwaste The high ard high-high alarm setpoints for the main stack radiation monitor, Unit 2 roof vent radiation monitor and Unit 3 roof vent radiation monitor are determined as follows:
Hich Alarm - the high alarm setpoint is set at approximately 3 x the normal monitor reading.
Hich-Hiah Alarm - the high-high alarm setpoint is set at a release rate from this vent of approximately 30% of the instantaneous release limit of 10 CFR 20 as specified in ODCMS 3.8.C.1.a for the most restrictive case (skin or total body) on an unidentified basis.
To determine these setpoints, solve the gaseous effluent dose rate equations in section IV.A of the ODCM to determine what main stack release rate and roof vent release rate will produce a dose rate of 150 mrem /yr to i
the total body (30% of the limit of 500 mrem /yr) and a dose rate of 900 mrem /yr to the skin (30% of the limit of 3000 i
mrem /yr) from each release point.
Using the smallest (most restrictive) release rate for each release point determine monitor response required to produce this release rate assuming a normal vent flow rate and pressure correction factor.
Se?. the high-high alarm for approximately this monitor response.
- i. t - t Page 5 of 48, Rev. 9 II.D.
Setooint Determination for Gaseous Radwaste Flow Monitors l
The alarm setpoint for the main stack flow monitor is as follows:
Low Flow Alarm
- 10,000 CFM. - This setting ensures that the main stack minimum dilution flow as specified in ODCMS 3.8.C.4.a is maintained.
1 The alarm setpoints for the roof vent' flow monitors are as follows:
l l
8 Low Flow Alarm
- 1.5 x 10 cfm 8
High Flow Alarm - 5.4 x 10 cfm III.
Licuid Pathway Dose Calculations l
III.A Licuid Radwaste Release Flow Rate Determination Peach Bottom Atomic Power Station Units 2 and 3 have one common discharge point for liquid releases.
The following l
calculation assures that the radwaste release limits are met.
The flow rate of liquid radwaste released from the site to l
areas at and beyond the SITE BOUNDARY shall be such that the concentration'of radioactive material after dilution shall be
~
limited'to the concentration specified in 10 CFR 20, Appendix l
B, Table II, Column 2 for radionuclides other than noble gases and 2E-4 pCi/ml total activity concentration for all noble gases as specified in ODCMS 3.8.B.1.
Each tank of radioactive l
waste is sampled prior to release and is quantitatively analyzed for identifiable gamma emitters as'specified in Table l
4.8.B.1 of the ODCMS.
From this gamma isotopic analysis the maximum permissible release flow rate is determined as follows:
Determine a Dilution Factor by:
Dilution Factor =
k ECL1 Ci/ml i the activity of each identified gamma emitter
=
in Ci/ml The effluent concentration specified in 10 CFR ECLi
=
20, Appendix B, Table II, Column 2 for i
radionuclides other than noble gases or 4
2 x 10 pCi/ml for noble gases.
l I
\\
Page 6 of 48, Rey r 9,,
III.A (Cont'd)
Determine the Maximum Permissible Release Rate with this Dilution Factor by:
A x 2. 0 x 105 Release Rate (gpm)
=
B X C X Dilution Factor The number of circulating water pumps running A
=
which will provide dilution 5
the flow rate in gpm for each circulating water 2.0 X 10
=
pump running margin of assurance which includes B
=
consideration of the maximum error in the activity setpoint, the maximum error in the flow setpoint, and possible loss of 5 out of the 6 possible circulating water pumps during a release.
The value used for B is 10.0.
concentration gradient factor.
The value used C
=
for C is 5.0 for discharge canal water levels less than 104' and 3.0 for canal water levels greater than 104'.
III.B ODCMS 4.8.B.2.1 Dose contributions from liquid effluents released to areas at and beyond the SITE BOUNDARY shall be calculated using the equation below.
This dose calculation uses those appropriate radionuclides listed in Table III.A.1.
These radionuclides account for virtually 100 percent of the total body dose and organ dose from liquid effluents.
The dose for each age group and each organ should be calculated to determine the maximum total body dose and organ dose for each quarter and the year, as appropriate.
Cumulative dose files for quarterly and yearly doses should be maintained separately and the maximum total body and organ dose reported in each case.
CM-1 NRC URI 88-33-01, T00353.
D=
[ Ap $ h tyCyF2 i
i 11 where:
The cumulative dose commitment to the total body or D
=
any organ, from liquid effluents for the total time period $ Ac in mrem.
2,
11 The length of the lth time period over which Ca and At
=
i Fi are averaged for the liquid release, in hours.
(.-1 4^1 Page 7 of 48, Rev. 9 1
III.B (Cont'd)
The average concentration of radionuclide, i, in Cu
=
undiluted liquid effluent during time period At from any liquid release, (determined by the effluent sampling analysis program, ODCMS Table 4.8.B.1),
in pCi/ml.
l The site related ingestion dose commitment. factor to Ar
=
i l
the total body or organ, 7,
for each radionuclide listed in Table III.A.1, in mrem-ml per hr-pCi.
See i
Site specific Data.**
The near field _ average dilution factor for Ca F
during any liquid effluent release.
Defined as the ratio of the maximum undiluted liquid waste flow during release to the average flow through the discharge structure.
III.C
~ODCMS 4.8.B.4,1 Projected dose contributions from liquid effluents shall be calculated using the methodology described in section III.B.
- See Note 1 in Bases l
I l
Page 8 of 48, Rey,p,,
TABLE III.A.1-LIQUID EFFLUENT INGESTION DOSE FACTORS (DECAY CORRECTED)
A r DOSE FACTOR (MREM-ML PER HR-pCi) i TOTAL BODY RADIO-NUCLIDE ADULT TEEN CHILD H-3 2.13E+00 1.53E+00 2.70E+00 NA-24 1.65E+02 1.70E+02 1.98E+02 P-32 5.93E+04 6.49E+04 8.33E+04 MN-54 9.82E+02 1.00E+03 1.08E+03 FE-55 1.31E+02 1.40E+02 1.96E+02 FE-59 1.14E+03 1.17E+03 1.36E+03 CO-58.
2.59E+02 2.62E+02 3.17E+02 CO-60 7.40E+02 7.48E+02 9.07E+02 ZN-65 3.87E+04 3.95E+04 4.16E+04 SR-89 8.83E+02 9.45E+02 1.48E+03 SR-90 1.88E+05' 1.56E+05 1.72E+05 TE-129M 2.01E+03 2.17E+03 2.79E+03 TE-131M 4.57E+02 4.81E+02 5.74E+02 TE-132 1.40E+03 1.44E+03 1.65E+03 I-131 1.86E+02 1.79E+02 2.36E+02 I-133 1.97E+01 2.03E+01 3.20E+01 CS-134 6.74E+05 3.88E+05 1.49E+05 CS-136 9.79E+04 9.15E+04 7.30E+04 CS-137 3.98E+05 2.20E+05 8.49E+04 BA-140 3.66E+01 3.62E+01 7.42E+01 NOTE:
The listed dose factors are for radionuclides that may be detected in liquid effluents and have significant dose consequences.
The factors are decayed for one day to account for the time between effluent release and ingestion of fish by the maximum exposed individual.
l l
- j. g ( ~i Page 9 of 48, Rev. 9 l
l TABLE III.A.1 l
LIQUID EFFLUENT INGESTION DOSE FACTORS (DECAY CORRECTED)
A7 DOSE FACTOR (MREM-ML PER HR-pCi) i LIVER RADIO-I NUCLIDE ADULT TEEN CHILD l
H-3 2.13E+00 1.53E+00 2.70E+00 l
l NA-24 1.65E+02 1.70E+02 1.98E+02 l
P-32 9.55E+04 1.04E+05 1.01E+05 MN-54 5.15E+03 5.06E+03 4.03E+03 FE-55 5.62E+02 6.01E+02 6.33E+02 FE-59 2.96E+03 3.02E+03 2.73E+03 l
CO-58 1.16E+02 1.14E+02 1.04E+02 l
CO-60 3.35E+02 3.32E+02 3.07E+02 l
ZN-65 8.55E+04 8.46E+04 6.69E+04 SR-89 no data no data no data SR-90 no data no data no data l
TE-129M 4.74E+03 5.09E+03 5.02E+03 l
TE-131M 5.48E+02 5.77E+02 5.40E+02 TE-132 1.48E+03 1.53E+03 1.36E+03 l
I-131 3.25E+02 3.32E+02 4.16E+02 I-133 6.48E+01 6.66E+01 8.45E+01 CS-134 8.25E+05 8.36E+05 7.06E+05 l
CS-136 1.36E+05 1.36E+05 1.13E+05 CS-137 6.07E+05 6.32E+05 5.75E+05 BA-140 7.00E-01 6.90E-01 1.11E+00 NOTE:
The listed dose factors are for radionuclides that may be detected in liquid effluents and have significant dose consequences.
The factors are decayed for one day to account for the time between effluent release and ingestion of fish by the maximum exposed individual.
l l
l
l Page 10 of 4 8, Rey,,e j, TABLE III.A.1 LIQUID EFFLUENT INGESTION DOSE FACTORS (DECAY CORRECTED)
A r DOSE FACTOR (MREM-ML PER HR-pCi) i BONE RADIO-NUCLIDE ADULT IEEE CHILD i
H-3 no data no data no data i
NA-24 1.65E+02 1.70E+02 1.98E+02 P-32 2.38E+05 2.58E+05 3.35E+05 l
MN-54 no data no data no data FE-55 8.12E+02 8.47E+02 1.19E+03 FE-59 1.26E+03 1.30E+03 1.68E+03 CO-58 no data no data no data CO-60 no data no data no data ZN-65 2.69E+04 2.43E+04 2.51E+04 SR-89 3.0BE+04 3.30E+04 5.19E+04 SR-90 7.67E+05 6.31E+05 6.78E+05 TE-129M 1.27E+04 1.37E+04 1.80E+04 TE-131M 1.12E+03 1.21E+03 1.56E+03 TE-132 2.29E+03 2.42E+03 3.07E+03 I-131 2.28E+02 2.38E+02 4.13E+02 I-133 3.72E+01 3.92E+01 6.84E+01 CS-134 3.47E+05 3.55E+05 4.30E+05 CS-136 3.45E+04 3.46E+04 4.10E+04 CS-137 4.44E+05 4.75E+05 6.01E+05 BA-140 5.57E+02 5.63E+02 1.27E+03 NOTE:
The listed dose factors are for radionuclides that may be detected in liquid effluents and have significant dose consequences.
The factors are decayed for one day to account for the time between effluent release and ingestion of fish by t
the maximum exposed individual.
5~i Page 11 of 48, Rev. 9 l
i TABLE III.A.1 LIQUID EFFLUENT INGESTION DOSE FACTORS (DECAY CORRECTED)
A;7 DOSE FACTOR (MREM-ML PER HR-pCi)
KIDNEY RADIO-NUCLIDE ADULT TEEN CHILD H-3 2.13E+00 1.53E+00 2.70E+00 NA-24 1.65E+02 1.70E+02 1.98E+02 P-32 no data no data no data MN-54 1.53E+03 1.51E+03 1.13E+03 FE-55 no data no data no data FE-59 no data no data no data CO-58 no data no data no data CO-60 no data no data no data ZN-65 5.72E+04 5.41E+04 4.22E+04 SR-89 no data no data no data SR-90 no data no data no data TE-129M 5.31E+04 5.74E+04 5.29E+04 TE-131M 5.55E+03 6.01E+03 5.22E+03 TE-132 1.43E+04 1.47E+04 1.27E+04 I-131 5.57E+02 5.73E+02 6.82E+02 I-133 1.12E+02 1.16E+02 1.41E+02 CS-134 2.67E+05 2.66E+05 2.19E+05 CS-136 7.57E+04 7.42E+04 6.00E+04 l
CS-137 2.06E+05 2.15E+05 1.87E+05 BA-140 2.38E-01 2.34E-01 3.62E-01 NOTE:
The listed dose factors are for radionuclides that may be detected in liquid effluents and have significant dose consequences.
The factors are decayed for one day to account for the time between effluent release and ingestion of fish by the maximum exposed individual.
I l
Page 12 of 48, Rey,,9,.,
TABLE III.A.1 LIQUID EFFLUENT INGESTION DOSE FACTORS (DECAY CORRECTED)
A r DOSE FACTOR (MREM-ML PER HR-pCi) i GI-LLI l
RADIO-NUCLIDE ADULT TEEN CHILD l
H-3 2.13E+00 1.53E+00 2.70E+00 NA-24 1.65E+0'2 1.70E+02 1.98E+02 P-32 1.73E+05 1.41E+05 5.98E+04 MN-54 1.58E+04 1.04E+04 3.38E+03 j
FE-55 3.22E+02 2.60E+02 1.17E+02 FE-59 9.90E+03 7.15E+03 2.84E+03 CO-58 2.35E+03 1.56E+03 6.04E+02 CO-60 6.30E+03 4.33E+03 1.70E+03 ZN-65 5.38E+04 3.58E+04 1.18E+04 SR-89 4.94E+03 3.93E+03
.2.01E+03 SR-90 2.22E+04 1.77E+04 9.13E+03 TE-129M 6.40E+04 5.15E+04 2.19E+04 TE-131M 5.44E+04 4.63E+04 2.19E+04 TE-132 7.02E+04 4.85E+04 1.37E+04 I-131 8.58E+01 6.57E+01 3.70E+01 I-133 5.82E+01 5.03E+01 3.40E+01 CS-134 1.44E+04 1.04E+04 3.80E+03 CS-136 1.55E+04 1.09E+04 3.96E+03 CS-137 1.18E+04 9.00E+03 3.60E+03 BA-140 1.15E+03 8.69E+02 6.43E+02 NOTE:
The listed dose factors are for radionuclides that may be detected in liquid effluents and have significant dose consequences.
The factors are decayed for one day to account for the time between effluent release and ingestion of fish by the maximum exposed individual.
l
' 5 Page 13 of 48, Rev. 9 l
IV.
Gaseous Pathway Dose Calculations l
l IV.A.
ODCMS 4.8.C.1.1 and 4.8.C.1.2 i
The dose rate in areas at and beyond the SITE BOUNDARY due to l
radioactive materials released in gaseous effluents shall be determined by the expressions below:
IV.A.1 Noble Gases:
The dose rate from radioactive noble gas releases shall be determined by either of two methods.
Method (a), the Gross Release Method, assumes that all noble gases released are the i
most limiting nuclide - Kr-88 for total body dose (vent and stack releases) and skin dose (vent releases) and Kr-87 for skin dose (stack releases).
Method (b), the Isotopic Analysis Method, utilizes the results of noble gas analyses required by ODCMS 4.8.C.1.1.
For normal operations, it is expected that method (a) will be used.
However, if noble gas releases are close to the limits as calculated by method (a), method (b) can be used to allow more operating flexibility by using data that more accurately reflect actual releases.
)
a.
Gross Release Method V gg + K (X70)y byv D,
=
n (L (RIO),+ 1.1B]by, + (Ly+ 1.1M) (X/0)y D,
=
g av where:
The location is the site boundary, 1097m SSE from the vents.
This location results in the highest calculated dose to an individual from noble gas releases.
D,
= total body dose rate, in mrem /yr.
n D,
= skin dose rate, in mrem /yr.
d V
= 4.72 X 10 mrem /yr per pCi/sec; the constant for Kr-88 accounting for the gamma radiation from the elevated finite plume.
This constant was developed using MARE program with plant specific inputs for PBAPS.
1
__.m Page 14 of 48, Rey vp,.
IV.A.1.a-. (Cont'd) b, The gross release rate of noble gases from
=
the stack determined by gross activity stack monitors averaged over one hour, in pCi/sec.
4 3
1.47 X 10 mrem /yr per,pCi/m ; the total body K
' =
dose factor due to gamma emissions for Kr-88 (Reg. Guide 1.109, Table B-1).
- 5. 3 3. X 10-7 sec/m ; the highest calculated 3
(X7D) y
=
annual average relative concentration.for any area at or beyond the SITE BOUNDARY for all vent releases.
buy The gross release rate of noble gases in
=
gaseous effluents from vent releases determined by gross activity vent monitors averaged over one hour,in pCi/sec.
3 3
2.37 x 10 mrem /yr per pCi/m ; the skin dose Ly
=
factor due to beta emissions for Kr-88. (Reg.
Guide 1.109, Table B-1).
3 3
9.73 X 10 mrem /yr per pCi/m ; the skin dose L,
=
factor due to beta emissions for Kr-87. (Reg.
Guide 1.109, Table B-1).
4 3
9.97 X 10 sec/m ; the highest calculated (X/0),
=
annual average relative concentration from the stack releases for any area at or beyond the SITE BOUNDARY.
4 1.74 X 10 mrad /yr per pCi/sec; the constant B
=
for Kr-87 accounting for the gamma radiation from the elevated finite plume.
This constant was developed using MARE program with plant specific inputs for PBAPS.
4 3
1.52 X 10 mrad /yr per pCi/m ; the air dose M
=
factor due to gamma emissions for Kr-88.
(Reg. Guide 1.109, Table B-1).
Unit conversion, converts air dose to skin 1.1'
=
dose, mrem / mrad.
- --E e
r
+ -
-*v m
-m
-emy
-mu+-
-w-T
+1
f.
\\
Page 15 of 48, Rev. 9 IV.A.1. b.
Isotopic Analysis Method Du=
(V dj, + Kj (X/Q) y jy )
3
((L (Y[D), + 1.1B )
j,+ (Lj + 1.1Mj) (Y/0)y (djy))
l D,
=
j 3
where:
The location is the site boundary, 1097m SSE from the vents.
This location results in the highest calculated dose to an individual from noble gas releases.
total body dose rate, in mrem /yr.
D
=
u skin dose, in mrem /yr.
D,
=
The constant for each identified noble gas v
=
j radionuclide for the gamma radiation from the elevated finite plume.
The constants were developed using the MARE program with plant specific inputs for PBAPS.
Values are listed on Table IV.A.1, in mrem /yr per pCi/sec.
b j, The release rate of noble gas radionuclide,
=
i, in gaseous effluents from the stack determined by isotopic analysis averaged over one hour, in pCi/sec.
The total body dose factor due to gamma K
=
2 emissions for each identified noble gas radionuclide.
Values are listed on Table 3
IV.A.1, in mrem /yr per pCi/m.
3 5.33 X 107 sec/m ; the highest calculated (77D) y
=
annual average relative concentration for any area at or beyond the SITE BOUNDARY for all vent releases.
bjy The release rate of noble gas radionuclide,
=
i, in gaseous effluents from all vent releases determined by isotopic analysis l
averaged over one hour, in pCi/sec.
The skin dose factor due to beta emissions Lj
=
for each identified noble gas radionuclide.
Values are listed on Table IV.A.1, in mrem /yr 3
per pCi/m.
1 L
...~.
l Page 16 of 48, Reyr p j.,
IV. A.1.b (Cont' d)
L 4
3 9.97 X 10 sec/m ; the highest calculated (TTD),
=
annual average relative concentration from the stack releases for any area at or beyond the SITE BOUNDARY.
Bj
= The constant for each identified noble gas I
radionuclide accounting.for the gamma i
radiation from the elevated finite plume.
The constants.were developed using MARE program with plant specific inputs'for PBAPS.
values are listed on Table IV.A.1, in mrad /yr per pCi/sec.
N
= The air dose factor due'to gamma.emis'sions 3
for each identified noble gas radionuclide.
Values are listed on Table IV.A.1, in mrad /yr 3
per pCi/m.
1.1
=. Unit-conversion, coverts air dose to' skin dose, mrem / mrad.
1 9
P l
O Page 17 of 4 Rev. F
(
- ABLE IV.A.1 - Constants for Isotopic Analysis Method (corrected for decay during transit)
Plume-Air Total Body Skin Gamma Air Beta Air Plume-Body Dose Factor Dose Factor Dose Factor Dose Factor Dose Factor Dose Factor B
K In M
N V,
3 i
i i
Radionuclide (mrad /yr per (mrem /yr per (mrem /yr per (mrad /yr per (mrad /yr per (mrem /yr per pCi/sec) pCi/m )
pCi/m )
pCi/m )
pCi/m )
pCi/sec)
Kr-85m 4.02E-05 1.17E+03 1.46E+03 1.23E+03 1.97E+03 3.76X-05 Kr-87 1.74E-04 5.92E+03 9.73E+03 6.17E+03 1.03E+04 1.66E-04 Kr-88 4.90E-04 1.47E+04 2.37E+03 i'.52E+04 2.93E+03 4.72E-04 Xe-133 1.19E-05 2.94E+02 3.06E+02 3.53E+02 1.05E<03 1.11E-05 Xe-133m 1.09E-05 2.51E+02 9.94E+02 3.27E+02 1.48E+03 1.01E-05 Xe-135 6.37E-05 1.81E+03 1.86E+03 1.92E+03 2.46E+03 5.95E-05 Xe-135m 6.61E-05 2.53E+03 5.76E+02 2.72E+03 5.99E+02 6.17E-05 Xe-138 1.52E-04 6.98E+03 3.26E+03 7.28E+03 3.75E+03 1.46E-04 and N are taken from Reg. Guide 1.109, Table B-1.
The values Biand Vi were The values K, L,
M, i
i i
i developed using the MARE program with plant specific inputs for PBAPS.
Page 18 of 48, Rev. p., o IV.A.2 Iodine-131, iodine-133, tritium and radioactive materials in particulate form, other than noble gases, with half-lives greater than eight days.
The dose rate shall be determined by either of two methods.
Method (a), the Iodine-131 Method, uses the iodine-131 releases and a correction factor to calculate the dose rate l
from all nuclides released.
Method (b), the Isotopic Analysis Method, utilizes all applicable nuclides.
For normal operations, it is expected that Method (a) will be used since iodine-131 dominates the critical pathway -
thyroid.
However, in the event iodine-131 releases are j
minimal (e.g.,
during long term shutdown) Method (b) will be used to provide accurate calculations.
In the absence of i
iodine-131 releases, the lung is the critical organ.
a.
Iodine-131 Method xvb l
D7= (CF)P[W z
s zs
- Wy where:
l The location is the site boundary, 1097m SSE from the vents.
D
= dose rate to the thyroid, in mrem /yr.
r CF
= 1.09; the correction factor accounting for the use of iodine-131 in lieu of all radionuclides released in gaseous effluents including iodine-133.
P
= 1.624 X 10 mrem /yr per pCi/n@; the dose 7
y parameter for I-131 via the inhalation pathways.
The dose factor is based on the critical individual organ, thyroid, and most l
restrictive age group, child.
All values are i
from Reg. Guide 1.109 (Tables E-5 and E-9).
I W,
= 1.03 X 10 sec/nd; the highest calculated 4
annual average relative concentration for any area at or beyond the SITE BOUNDARY from stack releases.
(SSE boundary) b y,
= The release rate of iodine-131 in gaseous effluents from the stack determined by the effluent sampling and analysis program (40DCMS Table 4.8.C.1) in pCi/sec.
N'
= 4.78 X 10 sec/nd; the highest calculated 4
y annual average relative concentration for any area at or beyond the SITE BOUNDARY for all vent releases (SSE boundary).
l
- i. ; i
Page 19 of 48, Rev. 9 IV.A.2. a.
(Cont'd) l b yy The release rate of iodine-131 in gaseous
=
effluents from all vent releases, determined by the effluent sampling and analysis program (ODCMS Table 4. 8.C.1) in pCi/sec.
IV.A.2. b.
Isotopic Analysis Method g b, + W d y}
P3 [W D
=
i y i t
where:
The location is the site boundary, 1097m SSE from the vents.
D
= dose rate to the lung, in mrem /yr.
r P
= The dose parameter for radionuclides other i
than noble gases for the inhalation pathway.
The dose factors are based on the critical individual organ-lung, and most restrictive age group-child.
All values are from Reg.
Guide 1.109 (Tables E-5 and E-9).
Values are listed on Table IV.A.2, in mrem /yr per 3
pCi/m.
4 3
W,
= 1.03 X 10 sec/m ; the highest calculated annual average relative concentration for any area at or beyond the SITE BOUNDARY from stack releases.
(SSE boundary) d,
= The release rate of radionuclides; i, in i
gaseous effluents from the stack determined by the effluent sampling and analysis program (ODCMS Table 4.8.C.1) in pCi/sec.
4 3
W
= 4.78 X 10 sec/m ; the highest calculated y
annual average relative concentration for any area at or beyond the SITE BOUNDARY for all vent releases.
(SSE boundary) by
= The release rate of radionuclides, i, in 3
gaseous effluents from all vent releases, determined by the effluent sampling and analysis program (ODCMS Table 4.8.C.1) in pCi/sec.
i l
. ~.
Page 20 of 48, Revr.S :
- TABLE IV.A.2 - CONSTANTS FOR ISOTQPIC ANALYSIS METHOD 8
(mrem /yr per. C1/m )
9 Pi - Inhalation 1
Radionuclide
. Luna Dose Factor Mn-54 1.58X10 -
6 Cr-51 1.70x10' l
6 Co-58 1.11x10 Co-60 7.07x10' 8
Zn-65 9.95x10 6
Sr-89 2.16x10 7
1.48x10 Sr-90 g 5
Ce-141 5.44x10 8
Cs-134
-1.21x10 8
Cs-137 1.04x10 Ba-140 1.74x10' i
i e
4
8 'I Page 21 of 48, Rev. 9 IV.B.
ODCMS 4.8.C.2.1 The air dose in areas at and beyond the SITE BOUNDARY due to i
noble gases re.lessed in gaseous effluents shall be determined by the exprcesions below.
The air dose shall be determined by either'of two methods.
Method (a), the Gross Release Method, assumes that all noble gases released are the most limiting nuclide - Kr-88 for gamma radiation and Kr-87 for beta radiation.
Method (b), the j
Isotopic Analysis Method, utilizes the-results'of noble gas analyses required by ODCMS 4.8.C.1.1.
For normal operations, it is expected that Method (a) will be used.
However, if noble gas releases are close to the limits as calculated by Method (a), Method (b) can be used to allow more operating flexibility by using data that more accurately reflect actual releases.
l IV.B.1 for gamma radiation:
a.
Gross Release Method D,
3.17 x 10-s [y (y73) y p + gg,]
=
y where:
The location is the SITE BOUNDARY 1097m SSE from the-vents.
This location results in the highest calculated gamma air dose from noble gas releases.
D
=-gamma air dose, in mrad.
y 3.17 x 10-s = years per second.
i 3
M
= 1.52 x 10' mrad /yr per pCi/m ; the air dose J
factor due to gamma emissions for Kr-88.
(Reg. Guide 1.109, Table B-1) 4 3
(X/0)y
= 5.33 x 10 sec/m ; the highest calculated anr.aal average relative concentration from vent releases for any area at or beyond the SITE BOUNDARY.
l Oy
= The gross release of noble gas radionuclides in gaseous effluents from all vents, determined by gross activity vent monitors, in pCi.
Releases shall be cumulative over the calendar quarter or year as appropriate.
Page 22 of 48, Rey. p,
IV.B.1, a.
(Cont'd) d
~B
= 4.90 x 10 mrad / year per pCi/sec; the constant for Kr-88 accounting for the gamma radiation from the elevated finite plume.
The constant was developed using the MARE program with plant specific-inputs for PBAPS.
D,
= The gross release of noble gas radionuclides in gaseous releases from the stack determined by gross activity stack monitor in pCi.
Releases shall be cumulative over the calendar quarter or year as appropriate.
b.
Isotopic Analysis Method
[M (X/0) y Djy + B Dj,)
D
= 3.17 x 10 -8 3
j y
where:
The location is the SITE BOUNDARY, 1097m SSE from the vents.
This location results in the highest calculated gamma air dose from noble gas releases.
gamma air dose, in mrad.
D
=
y 3.17 x 10-8 = years per second.
The air dose factor due to gamma emissions My
=
for each identified noble gas radionuclide.
Values are' listed on Table IV.A.1, in mrad /yr 3
per Ci/m.
5. 33 x 10-7 sec/m'; the highest calculated (X/D) y
=
average relative concentration from vent releases for any area at or beyond the SITE BOUNDARY.
l The release of noble gas radionuclides, i, in Djy
=
gaseous effluents from all vents as determined by isotopic analysis, in Ci.
Releases shall be cumulative over the calendar quarter or year, as appropriate.
The constant for each identified noble gas B
=
3 radionuclide accounting for the gamma radiation for the elevated finite plume.
The constants were developed using the MARE program with plant specific inputs for PBAPS.
Values are listed on Table IV.A.1, in mrad /yr per Ci/sec.
- - 1 Paga 23 of 48, Rev. 9 IV.B.1. b.
(Cont'd) l D,
= The release of noble gas radionuclides, i, in 2
gaseous effluents from the stack determined by. isotopic analysis, in pCi.
Releases shall be cumulative over the calendar quarter or year, as appropriate.
_IV.B.2.
for beta radiation:
l a.
Gross Release Method D,
= 3.17 x 10 -8 N [(Y/D) y Dy + (X/ 0), D, ]
where:
The location is the SITE BOUNDARY 1097m SSE from the vents.
This location results in the highest calculated gamma air dose from noble gas releases.
L D,
= beta air dose, in mrad.
l 3.17 x 10-s = years per second.
t 4
3 1.03 x 10 mrad /yr per pCi/m ; the air dose l
N
=
factor due to beta emissions for Kr-87.
(Reg. Guide 1.109, Table B-1) l 4
3 5.33 x 10 sec/m ; the highest calculated l
(X/0)y
=
annual average-relative concentration from l
vent releases for any area at or beyond the l
SITE BOUNDARY.
l Dy The gross release of noble gas radionuclides
=
in gaseous effluents from all vents l
determined by gross activity _ vent monitors, in pCi.
Releases shall be cumulative over the calendar quarter or year, as appropriate.
l 9.97 x 10-8 sec/m ; the highest calculated 3
l (ZRD),
=
annual average relative concentration from the stack releases for any area at or beyond the SITE BOUNDARY.
l D,
The gross release of noble gas radionuclides
=
in gaseous releases from the stack determined by gross activity stack monitors, in pCi.
Releases shall be cumulative over the calendar quarter or year, as appropriate.
4 i
l
Page 24 of 48, Rey. ;9.
IV.B.2. b.
Isotopic Analysis Method o
= 3.17 x 10 -e
. Nj ((X/0) y Djy + (X/0),Oj,)
L p
3.17 x 10-a = years per second.
Nj
= The air dose factor due to beta emissions for each identified noble gas radionuclide.
Values are listed on Table IV.A.1, in mrad /yr 3
per pCi/m.
4 3
('X/D) y
= 5.33 x 10 sec/m ; the highest calcu' ated annual average relative concentration from vent releases-for any area at or beyond the SITE BOUNDARY.
Djy
= The release of noble gas radionuclide, i, in gaseous effluents from all vents as determined by isotopic analysis, in pCi.
Releases shall be cumulative over the calendar quarter or year, as appropriate.
(X/0),
= 9.97 x 10s sec/m ; the highest calculated 3
annual average relative concentration from the stack releases for any area at or beyond the SITE BOUNDARY.
Dj,
= The release of noble gas radionuclide, i, in gaseous effluents from the stack as determined by isotopic analysis, in gCi.
Releases shall be cumulative over the calendar quarter or year, as appropriate.
IV.C ODCMS 4.8.C.3.1 The dose to an individual from iodine-131, iodine-133, tritium and radioactive materials in particulate form and radionuclides other than noble gases with half-lives greater than eight days in gaseous effluents released to areas at and beyond the SITE BOUNDARY.
j The dose shall be determined by one of two methods.
Method (a), the Iodine-131 Method, uses the iodine-131 releases and a correction factor to calculate the dose from all nuclides released.
Method (b), the Isotopic Analysis Method, utilizes all applicable nuclides.
For normal operation, it is expected that Method (a) will be used since iodine-131 dominates the critical pathway -
thyroid.
However, in the event iodine-131 releases are minimal (e.g. during long term shutdown) Method (b) will be used to provide accurate calculations.
In the absence of
{
iodine-131 releases, the liver is the critical organ.
j l
I".
Page 25 of 48, Rev. 9 IV.C.
a.
Iodine - 131 Method W Dyy]
3.17 x 10-s (CF) ( 0. 5 ) R (W Dy, +
D
=
y 3
r where:
Location is the critical pathway dairy 2103m SSW from vents.
critical organ dose, thyroid, from all D
=
r pathways, in mrem.
3.17 x 10-e = years per second.
1.09; the correction factor accounting for CF
=
the use of Iodine-131 in lieu of all radio-nuclides released in gaseous effluents including Iodine-133.
fraction of iodine releases which are 0.5
=
nonelemental.
3.08 x 10" m2 (mrem /yr) per pCi/sec; the dose R
=
factor for iodine-131.
The dose factor is based on the critical individual organ, thyroid, and most restrictive age group, infant.
See Site Specific Data.**
l 1
4.95 x 10 meters-2; (37g) 40 W,
=
for the food pathway for stack releases.
The release of iodine-131 from the stack Dy,
=
determined by the effluent sampling and analysis program (ODCMS Table 4.8.C.1), in pCi.
Releases shall be cumulative over the calendar quarter or year, as appropriate.
1.14 x 10 met ers.2; (37g) 4 W
=
y for the food pathway for vent releases.
Dyy The release of iodine-131 from the vent
=
determined by the effluent sampling and analysis program (ODCMS Table 4.8.C.1),
in pCi.
Releases shall be cumulative over the calendar quarter or year, as appropriate.
- See Note 2 in Bases.
Page :26 of 4 8, ReyfS IV.C.
b.
Isotopic Analysis Method W D y}
D
= 3.17 x 10**
R [W D g +
3 s i y i z
where:
Location is the critical pathway dairy 2103m SSW from vents.
critical organ dose, liver, from all D
=
t pathways, in mrem.
3.17 x 10-8 = years per second.
The dose factor.for each identified R
=
f radionuclide, 1, based on the critical individual organ, liver and most restrictive age group, infant.
Values are listed on Table IV.C.1, in m2 (mrem /yr) per pCi/sec.
i W,
= 4. 95 x' 10*" meters-2; (2%RD) for the food pathway for stack releases.
The release of radionuclides, i, in gaseous D,
3 j
effluents from the stack determined by the effluent sampling (ODCMS Table 4.8.C.1),
in pCi.
Releases shall be cumulative over the calendar quarter or year, as appropriate.
1.14 x 10 meters-2; (yf3)
W
=
y l
for the food pathway for vent releases.
Djy The release of radionuclides, i, in gaseous
=
effluents from the vents determined by the effluent sampling and analysis program (ODCMS Table 4.8.C.1) in pCi.
Release shall be cumulative over the calendar quarter or year, as appropriate.
l :-
i II
Page 27'.of 48, Rev. 9 TABLE IV.C.1 - CONSTANTS FOR ISOTOPIC ANALYSIS METHOD 2
(m (m*.em/yr) per pCi/sec) l l
RADIONUCLIDE Bi-7 Mn-54 1.93 x 10 l-Cr-51 5.14 x 10'*
6 Co-58
-9.58 x 10 7
Co-60 4.69 x 10 Zn-65 9.21 x 10' 8
Sr-89
- 1. 31 x 10
'1.67 x 1010
- i 3
Ce-141 8.68.x 10
.l Cs-134 3.54'x 1020 10 Cs-137 3.24 x 10 Ba-140 7.09 x 10' There is no-liver dose factor given in R.G.
1.109 for'these nuclides.
Therefore, the whole body dose factor.was used.
1 l
l i
I l
l 1
Page 28 of 48, Rey.:9.
IV.D ODCMS 4.8.C.5.1 The projected doses from releases of gaseous effluents to areas at and beyond the SITE BOUNDARY shall be calculated in accordance with the following sections of this manual:
a.
gamma air dose - IV.B.1 b.
beta air dose
- IV.B.2 c.
organ dose IV.C The projected dose calculation shall be based on expected release from plant operation.
The normal release pathways result in the maximum releases from the plant.
Any alternative release pathways result in lower releases and, therefore, lower doses.
IV.E Technical Recuirements Manual Test Recuirement (TR) 3.5.3 IV.E.1 The two types of recombiner hydrogen analyzers currently used at Peach Bottom are:
a.
Hays Thermal Conductivity type (Analyzers 4083, 4084, 4029, and 4047 on Unit 2.
Analyzers 5083, 5084, 5029 and 5057 on Unit 3.)
b.
Scott Series 900 Helium - Immune type (Analyzers 4083X and 4084X on Unit 2.
Analyzers 5083X and 5084X on Unit 3.)
These analyzers will be replaced, per Mod P61, with the Whittaker Electrochemical type (Analyzers 4083A and 4083B on Unit 2.
Analyzers 5083A and 5083B on Unit 3).
IV.E.2 The calibration gases for the three types are:
a.
Hays Analyzers Zero Gas - Air Calibration Gas - 4% Hydrogen, Balance Nitrogen b.
Scott Analyzers Zero Gas - Air Calibration Gas - 2% Hydrogen, Balance Air c.
Whittaker Analyzers Calibration Gas - 2% Hydrogen, Balance Air V.A.
ODCMS 4.8.D.1.1 and 4.8.D.1.2 If the doses as calculated by the equations in this manual do not exceed the limits given in ODCMS 3.8.B.2, 3.8.C.2, or 3.8.C.3 by more than two times, the conditions of ODCMS 3.8.D.1 have been met.
o 1
?
Page 29 of 48, Rev. 9 V.A.
(Cont'd)
If the doses as calculated by the equations in this manual exceed the limits given in ODCMS 3.8.B.2, 3.8.C.2, or 3.8.C.3 by more than two times, the maximum dose or dose commitment to l
a real individual shall be determined utilizing the methodology provided in Regulatory Guide 1.109, " Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I",
Revision 1, October 1977.
Any deviations from the methodology provided in Regulatory Guide 1.109 shall be documented in the Special Report to be prepared in accordance with ODCMS 3.8.D.1.
The cumulative dose contribution from direct radiation from the two reactors at the site and from radwaste storage shall be determined by the following methods:
Cumulative doc-c contribution from direct radiation =
Total dose at th.e site of interest (as evaluated by TLD measurement) -
Mean of background dose (as evaluated by.TLD's at background sites) -
Effluent contribution to dose (as evaluated by ODCMS 4.8.D.1.1).
This evaluation is in accordance with ANSI /ANS 6.6.1-1979 Section 7.
The error using this method is estimated to be j
approximately 8%.
VI.A.
Unicue Rooortino Recuirement ODCMS 3.10.3, Dose Calculations for the Radiation Dose Assessment Report The assessment of radiation doses for the radiation dose assessment report shall be performed utilizing the methodology provided in Regulatory Guide 1.109, " Calculation of Annual Doses To Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I",
Revision 1, October 1977.
Any deviations from the methodology provided in Regulatory Guide 1.109 shall be documented in the radiation dose assessment report.
The meteorological conditions concurrent with the time of release of radioactive materials (as determined by sampling frequency of measurement) or approximate methods shall be used as input to the dose model.
The Radiation Dose Assessment Report shall be' submitted within 120 days after January 1 of each year in order to allow time for the calculation of rc.diation doses following publication of radioactive releases in the Radioactive Effluent Release Report.
There is a very short turnaround time between the determination of all radioactive releases and publication of the Radioactive Effluent Release Report.
This would not allow time for calculation of radiation doses in time for publication in the same report.
3 Page 30 of 48, Rev. 9 VII.A ODCMS 4.8.E.1.1 and 4.8.E.1.2 The radiological environment monitoring samples shall be collected pursuant to Table VII.A.1 from the locations shown l
on Figures VII.A.1, VII.A.2, and VII.A.3, and shall be analyzed pursuant to the require (aents of. Table VII.A.1.
l
~Page 31 of 48, Rev. 9-TABLE VII.A-1 p
ODCM - Peach Bottom Atomic Power Station Radiological Environmental Monitoring Program J
Pathway
' Station Distance and Direction Collection Method Analyses Code from PBAPS Vents and Discusion i
t f
l I.
Direct Radiation Site Boundary 1L 1,256 feet NE of site 1 set of four (4) TLDs Gamma Dose quarterly 1A 1,396 feet SE of site from each location at 2
4,661 feet SE of sits least quarterly lI 2,851 feet SSE of site Gamma dose quarterly 1C 4,513 feet SSE of site 1J 3,755 feet S of site 1F 2,707 feet SSW of site TLD sites.were chosen 40 7,050 feet SW of site in accordance with 1NN 2,547 feet WSW of site Peach Bottom ODCMS 1H 3,104 feet W of site Table 4.8.E.1 Item 1.
1G 3,173 feet WNW of site Site Boundary stations-1B 2,587 feet NW of' site-all sectors except i
1E 3,136 feet'NNW of site several along Conowingo l
Pond.
These sectors Intermediate are monitored by
[
Distance 15 19,449 feet N of site stations on the east i
22 13,230 feet ~NNE of site side of Conowingo Pond.
l 44 27,480 feet NE of site The 5 mile vicinity i
~'
32 15,213 feet ENE of site stations cover all 45 18,524 feet ENE of site sectors.
14 10,397 feet E of site 17 21,966 feet ESE:of site The distant and special i
31A 24,105 feet SE of site interest stations i
4K 45,721 feet SE of site provide information in
~i 23 5,276' feet SSE of site population centers and 27-13,859 feet S of. site control locations.
48 25,772 feet SSW of site t
Page 32 of 48, Rev. 9 TABLE VII.A-1 ODCM - Peach Bottom Atomic Power Station Radiological Environmental Monitoring Program Pathway Station
. Distance and_ Direction Collection Method Analyses Code from PBAPS Vents and Discusion 3A 19,114 feet SW of site 49 20,673 feet WSW of site r
50 25,677 feet W of site 51 20,511 feet PGM of site 26 22,093 feet NW of site i
6B 30,538 feet NW of site 42 21,954 feet NNW of site Distant 43 26,931 feet NNE of site and 5
24,482 feet E of site Special 16 67,788 feet E of site Interest 24 58,048 feet ESE of site t
46 23,483 feet SSE of site 47 22,153 feet S of site 18 51,413 feet W of site 19 C 106,354 feet WNW of site II.
Airborne Particulates 1Z 1,396 feet SE of site Approximately 1 cfm Gross beta analysis 1B 2,587 feet NW of site continuous flow through on each weekly i
2 4,661 feet SE of site glass fiber filter sample.
Gamma 3A 19,114 feet SW of site which is collected spectrometry shall be 22G1 C 162,565 feet NE of site weekly.
done when gross beta exceeds ten times the These stations provide yearly mean of for coverage of the t
be w
Page 33 of 48, Rev.
9-
~
TABLE VII.A-1 ODCM - Peach Bottom Atomic Power Station Radiological Environmental Monitoring Program Pathway Station Distance and Direction Collection Method Analyses Code from PBAPS Vents and Discusion highest annual average control station ground level D/Q near value.
the site boundary, the community with the Gross beta analysis highest annual average done 224 hr after D/Q and a control sampling to allow for location.
Radon and Thoron daughter decay.
Gamma Spec on quarterly composite by location.
Iodine 1Z 1,396 feet SE of site A TEDA impregnated Iodine 131 weekly 1B 2,587 feet NW of site flow-through cartridge 2
4,661 feet SE of site is connected to air 3A 19,114 feet SW of site sampler and is 22G1 C 162,565 feet NE of site collected weekly at site filter change.
III.
Waterborne Surface 1LL C
1,256 feet NE of site Sample collected from a Gamma isotopic
Page 34 of'48,'Rev. 9 TABLE VII.A-1 ODCM.- Peach Bottom Atomic Power Station Radiological Environmental Monitoring Program Pathway Station Distance and Direction Collection Method Analyses Code from PBAPS Vents
.and Discusion 1MM 5,470 feet SE of site continuous water analysis monthly; sampler, monthly.
In event sampler is H-3 c ri quarterly inoperable, daily grab composite samples will be collected.until sampler returned to service.
Drinking 4L 45,721 feet SE of site Sample collected from a Gross beta and gamma 6I C
30,337 feet NW of site continuous water isotopic monthly, sampler monthly.
In event sampler is H-3 on quarterly inoperable, weekly grab composite samples will be i
collected until sampler returned to service.
Sediment 4J 7,346 feet SE of site A sediment sample is Gamma isotopic taken down stream of analysis each sample discharge semi-annually.
IV.
Incestion Milk A
C 30,493 feet WSW of site Sample of fresh milk is I-131 analyses on-collected from each each sample G
7,855 feet.SSW of site farm biweekly when cows J
5,119 feet W of site are on pasture (April Gamma isotopic O
12,241 feet SW of site-through October),
analysis or Cs-134, -
monthly at other times.
b.
D*
Page 35 of 48, Rev. V TABLE VII.A-1 ODCM - Peach Bottom Atomic Power Station Radiological Environmental Monitoring Program Pathway Station Distance and Direction Collection Method Analyses Code from PBAPS Vents and Discusion 137 by chemical separation quarterly Fish 4
7,162 feet SE of site Two species of Gamma isotopic 6
C 57,347 feet NW of site recreationally analyses on edible important fish portions.
(predator and bottom feeder) sampled in season or semiannually if not seasonal.
Food Two offsite locations of highest samples of three (3)
Gamma isotopic and I-Products predicted annual average ground different kinds of 131 anaysis level D/Q and one location (15-broad leaf vegetation 30 km distance) in the least montl'ly when available prevalent wind direction as if milk sampling is not determined using the results of performed the most recent annual Landuse Survey.
C = Control Location
Page 36 of 48, Rev. 9
\\
N NN NNE e
NW NE 12 "d
a et 4
- 1G
,,f tLL W-
. is s
E s
NN' 1A/1 WSW e1F ESE 11 '
2e g
sw sE
,c MILE ssw SSE
'4
'/
,e
(
FIGURE VII.A.1 ENVIRONMENTAL SAMPLING STATIONS AT SITE BOUNDARY AREA TO PEACH BOTTOM
Page 37 of 48, Rev. 9
)
i h
N 43 NNE 7
NW q
'k NW s
e15 NE 44 7
4 26 22 ENE WN 51 445
./
5 W
E u
N O
3 4J 17 O
A e3A l
ESE WSW e
31A 46 h
a*
46
- g%
5 MILE R ADIV S
SSW S
gs 1
FIGURE VII.A.2 ENVIRONMENTAL SAMPLING STATIONS AT INTERMEDIATE DISTANCES FROM PEACH BOTTOM SITE
'h 7
E
?
ti
\\ } ~Q
=,
ns i
+6,a 5
+
u.
h I
W O
y 5
i W
g>D N
6 8
km S
x m
N.
b j
go f*
N 905 c>
6 W
pO b
bkb b
gp cez ca ge e
5
!:iB e
me to gs
~
a s
e' e
?
b k
/
Page 39 of 48, Rev. 9 l l
'lI!
egg
!!1 Iai 8'
ll
=g!
c___~___ &
=
in lli(NV) 8 'I --c o--
^
g l
1 --c a.-
-eE
=
h SE 6
~
C1 Z3 2
lgb
@k lif i
gg. _ _ _ _.J g-g E
b c
5I si i
IE Bi 5"
e3 gg g
5I I
E 5
8!
E q5s n
wS h
p,s c l
h y
+
C JL
{lI P
k'
!fgh5!
6 vg I
lI b 4
1 1
l PECO ENERGY COMPANY l
PBAPS UNITS 2 & 3 j
I OFFGAS RADWASTE TREATMENT SYSTEM PRE MOD 5386
m.-
pe-d s*
O Q
GUARD O
N/
BED q
SAfPLE l
e d 'aIa' Etcrons PROBES j
De 15 1 2HO r
yt 1p 1 1 @IAG rSTAGE h
I 303 I
fMAIN 3
FROMp }
ABSORBER NoRMBL ERNGC RECOMBINEA--
g MoMIToa (BED J
nn (UMT 2) l V
N
- m
.iooing y
y l
- Mo*Ls sa.
,g,
l conornsta coMoEM5
WE ONLY li l
x
[ll M2 2H2ANALY2ERS l
O ca E*
m l
e e,
U mg*
USED OM.Y l VATER C'
PERMOD P61 Miorsawer m
l SEPARATOR g
ggg OFFGAS Monnom DURNG lr l TANK
., nanculair e
<m x FILTERS STARTUP ANAL
, toD1ME DI 3: g 4-Em eg 4
c
- o a..
g l
FROMUMT3; MAN Da dl O
a
+
b 5 u)
MA A S RBERBED OFF-GAS MECHAMCAL I
ana VACUUMPUMP l
STACK
@ D' l
H2 i"5 FROM O
h h MVPAND I '
FROMTURB P
STEAM I
i l
PACKING STEAMSEALS STEAMPACKNG EXHAUSTER(UMT 3)
(UMT2) c,'[^"s17a*
EXHAUSTER BLOVER(2)
CONDENSATE :-
DRAN TM OUTSIDE C AIR J
MANSTACK DILUTION FANS (3)
l Page 41 of 48, Rev. 9
- o REFUELINGr FLOCR EXH' (3) 10 DINE AND
()() PARTICULATE REACTOR '
FILTERS BLDG EXH '
g33
[r REACTOR BLDG EQUIP EELL EXH '
I
/l(2)
G) i
,g RECOMBINER <
V//J
[ h- (2)
'M BLDG EXH
'l l--
RECOMBINERr U
BLDG EXH
>c I
{-
TURBINE BLDG r AREA EXH g)
[-
A m {I TURBINE BLDG e
/l 10 DINE AND EQUIP CELL EXH '
(2)
(2)
()() PARTICULATE g
TURBINE DPERATINGt
{w CQ FLOOR EXH (3) g U
h RADVASTE<
]g AREA EXH '
g)
$E[LE
^
2)
)
l
=
w 'm em,
[a, (B
[-
LAB AND TOILET EXH' (2)
E HOODe, FILTER PECO ENERGY COMPANY PBAPS UNITS 2 & 3 VENTILATION EXHAUST WASTE TREATMENT SYSTEM PRE MOD 5384
ER CR ET QE EA QU UA LD UR IC LV IB BR PT PI LE n0 A
N Er E
S t
Xu EC XT E
GO HN XH HE LB t
M B
E HE Ea
_i M
- L Xl D
E D
t H
EG o
L Q
EG HE X
o A
U X
R H
H I
D B
P 4
'e
'8
,e
,8
,s FT LU OR CB RI AT N
EE RU ER BR TL X
gR HC AB LE BR FR IB E
P E
GO e
O 2
R f
H EB f
GC OU X
M f
f EA T
RE
/
/
f A
TN
/
7 gS I
/
/
A P
EO L
T L
XI
/
/
XR EI D
/
D HN
/
,/
V
/
yT N
H XN E
E f
j HG X
E G
)
G R
)
H
)
{
's E
'e
]
,t
(
(
(
2 2
2
(
(
N
)
)
)
2 2
T P
)
)
I PE T L BC R A AO P E O A T P
A S
I SE U
(
>[
f
(
>[
(
y(
S E
S T O N
T T M N UE E
NR
(
(
(
(
(
M N e
(
(
(
(
3 2
3 2
2 3
3 O
E IG 2
2 2
2
)
)
)
)
)
)
)
)
T X TY
)
)
)
)
D n
H S
f S
5 A
C Y
j 3
U 2O S
8 S
M r
T 4
T
&P L
E A
T
=
M W 3N E
b @Dtjp>ZQ yZp )V&4UY R
A Y
ZU<
w e
S T
E Pa g
MN e
N l
P OO O
MW O D A NR 4
N I
P OI B
I R
IM 2
O D
B I
R IE L
N T T A N I
OL O D A
E E C R o
L N
T TR E E I
O A G
U M
f C
L A
G U RN A
A N
A L
G S
T A
E E
G 4
S T
E 8
E R
e
.. v 9
,l),
I l,I
N.$
Ou yd b m W
ER E
C TD C
OR D.
RA I
L TN E
A C
N T
K I
G SF i
U UL RG E )R TD
-(
-(
AR Y1 l# ]A C
N
{
f O
FV FDF I
I RL L A L AO TS TID ET EN R RE R
-m T
H E
S U
I M
E SF R
G E
R AL DV I
H E
B H
R V
P)
M P
A N
G C
LR I
I P
E E
E P E l
4]
E R
N D
LR E
C W
TR B
S Y
A AA U
S T
NI L
U S
E K N D
R E
R NI E
R v
G S
l TNVMS E
C A
S R
E V
U V
T T
A I
W M
C A
E S
(E P
E T
2 T
)
E E
W R
A
"(
T E
R 2
(
(
e
)
(
R 2
E
)
FDL
(
(
I IRA O
O f
L AU U
U I
TIN L
L
{
END E
E R
R T
T Y
O O
+
F F
F R
R E
=
H B
R C
)
C ST W
TO
)
)
N E
(
TDL "m
N 2
ara S
)
NAu CDVC A
KI n I
T Np AI AR E
(
a 3
N S ACTC 2
y L HEU
)
A RL cga zo R
A G
T agf Uw E
IN G
e
$ FH< da N
O*
fH "13
~
HsQ lplb 5
H
Page 44 of 48, Rev. 9 VIII.
Bases Site Soecific Data NOTE 1 Liquid dose factors, Ar, for.section III.B i
were developed using che following site specific data.
The liquid pathways involved are drinking water and fish.
(Uy/Dy+ U,. x B F ) K x D F, x R C Ap
=
3 n
liters per year; maximum age group usage of drinking Uy
=
water (Reg. Guide 1.109, Table'E-5) 5.4; average annual dilution at Conowingo intake D
=
y kg per year; maximum age group usage of fish (Reg.
U
=
f Guide 1.109, Table E-5) bicaccumulation factor for nuclide, i, in freshwater BF
=
3 fish.
Reg. Guide 1.109, Table A-1, except P-32 which uses a.value of 3.0 x 103 pCi/kg per pCi/ liter.
6 3
3 (10 pCi/uCi x 10 ml/l + 8760 hr/yr) 1.14 x 10 K
=
=
o units conversion factor.
dose conversion factor for nuclide, i, for the age DFj
=
group in total body or organ, as applicable.
Reg.
Guide 1.109, Table E-11, except-P-32 bone which uses a value as indicated below.
3.0 x 10'8. mrem /pCi 1.16; reconcentration from PBAPS' discharge back RC
=
through PBAPS intake.
The data for Dw and RC were derived from data published in Peach Bottom Atomic Potter Station Units 2 and 3 (Docket Nos.
50-277 and 50-278) Radioactive Effluent Dose Assessment, Enclosure A, September 30, 1976.
All other data except P-32 BF and DF were used as given in Reg. Guide 1.109, Revision 1, October 1977.
The P-32 BF and DF were used in accordance with information supplied in Branagan, E.F.,
- Nichols, C.R.,
and
- Willis, C.A.,
"The Importance of P-32 in Nuclear Reactor Liquid Effluents", NRC, 6/82.
The teen and child dose factors were derived by the ratio of the adult bone dose factors in Reg. Guide 1.109 and Branagan, et al.
Page 45 of 48, Rev. 9 VIII.
(Cont'd)
NOTE 2 To develop constant R for section IV.C, the following site specific data were used:
e "
R[(D/0) = K' A +A F,(r) (DFL)
- +
g Y,
Y, g
y where:
6 K'
10 pCi/pCi; unit conversion facte.
=
50 kg/ day; cow's consumption rate O
=
f 330 1/yr; yearly milk consumption by an infant U,,
=
radioactive decay constant'for nuclide of interest, 1
=
3 4
s e c'3 (e.g. 9.97 x 10 sec' for I 131) 5.73 x 10 sec1; decay constant for removal of 4
A
=
y activity in leaf and plant surfaces stable element transfer coefficient for nuclide of F,
=
4 interest, day / liter (e.g. 6.0 x 10 day / liter for I-131) fraction of deposited nuclide retained in cow's feed
.r
=
grass, 1.0 for radiciodine; 0.2 for particulates DFL =
ingestion dose factor in infant for nuclide of j
4 interest, mrem /pCi (e.g. 1.39 x 10 mrem /pCi for I-131) f, 0.6; the fraction of the year the cow is on pasture
=
(average of all farms) f, 0.487; the fraction of cow feed that is pasture
=
grass while the cow is on pasture (average of all farms) 2 0.7 kg/m ; the agricultural productivity of pasture Y,
=
feed grass 2
2.0 kg/m ; the agricultural productivity of stored Y,
=
feed 5
1.73 x 10 sec (2 days) ; the transport time from t
=
f pasture, to cow, to milk, to receptor 6
7.78 x 10 sec (90 days); the transport time from C
=
3 pasture, to harvest, to cow, to milk, to receptor l
Page 46 of 48, Rev. 9
.i VIII.
(Cont'd)
The pathway is the grass-cow-milk ingestion pathway.
These data were derived from data published in Peach Bottom Atomic Power Station Units 2 and 3 (Docket Nos. 50-277 and 50-278)
Radioactive Effluent Dose Assessment, Enclosure A, September 30, 1976.
All other data were used as given in Reg. Guide 1.109, Revision 1, October 1977.
ODCMS 4.8.B.2.1, Licuid Pathway Dose Calculations The equations for calculating the doses due to the actual release rates of radioactive materials in liquid effluents were developed from the methodology provided in Regulatory Guide 1.109, " Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I",
Revision 1, October 1977 and NUREG-0133 " Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants",
October 1978.
ODCMS 4.8.C.1.1 and 4.8.C.1.2 Dose Noble Gases The equations for calculating the doses due to the actual release rates of radioactive noble gases in gaseous effluents were developed from the methodology provided in Regulatory Guide 1.109, " Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I",
Revision 1, October 1977, NUREG-0133 " Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants", August 1978, and the atmospheric dispersion model presented in Information Recuested in Enclosure 2 to letter from Georce Lear to E. G.
Bauer dated February 17, 1976, September 30, 1976-The specified equations provide for determining the air doses in areas at and beyond the SITE BOUNDARY based upon the historical average atmospheric conditions.
The dose due to noble gas release as calculated by the Gross Release Method is much more conservative than the dose calculated by the Isotopic Analysis Method.
Assuming the release rates given in Radioactive Effluent Dose Assessment, September 30, 1976, the values calculated by the Gross Release Method for total body dose rate and skin dose rate are 6.0 times and 5.7 times, respectively, the values calculated by the Isotopic Analysis Method.
Page 47 of 48, Rev. 9
'VIII.
(Cont'd)
The model Technical Specification LCO of NUREG-0133 for all radionuclides and radioactive materials in particulate form and radionuclides other than noble gases requires that the instantaneous dose rate be less than the equivalent of 1500 mrem per year.
For the purpose of calculating this instantaneous dose rate, thyroid dose from iodine-131 through the inhalation pathway will be used.
Since the operating history to date indicates that iodine-131 releases have had the major dose impact, this approach is appropriate.
The value calculated is increased by nine per cent to account for the thyroid dose from all other nuclides.
This allows for expedited analysis and calculation of compliance with the requirements of CDCMS 3.8.C.1.
In the event that the plant is shutdown long enough so that iodine-131 is no longer present in gaseous effluents, an Isotopic Analysis Method is available. Since no iodines are present, the critical organ changes from the thyroid to the lung.
ODCMS 4.8.C.2.1 Dose Noble Gases The equations for calculating the doses due to the actual release rates of radioactive noble gases in gaseous effluents were developed from the methodology provided in Regulatory Guide 1.109, " Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I",
Revision 1, October 1977, NUREG-0133 " Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants", August 1978, and the atmospheric dispersion model presented in Information Recuested in Enclosure 2 to letter from Georce Lear to E.
G.
Bauer dated February 17, 1976, September 30, 1976.
The specified equations provide for determining the air doses in areas at and beyond the SITE BOUNDARY based upon the historical average atmospheric conditions.
The dose due to noble gas releases as calculated by the Gross Release Method is much more conservative than the dose calculated by the Isotopic Analysis Method.
Assuming the releases rates given in Radioactive Effluent Dose Assessment, September 30, 1976, the values calculated by the Gross Release Method for total body dose rate and skin dose rate are 4.3 times and 7.2 times, respectively, the values calculated by the Isotopic Analysis Method.
Page 48 of 48, Rev. 9 VIII.
(Cont'd)
ODCMS 4.8.C.3.1 Dose, Iodine-131, Iodine-133, Tritium, and Radioactive Material in Particulate Form The equations for calculating the doses due to the actual release rates of radiciodines, radioactive material in particulate form, and radionuclides other than noble gases with half-lives greater than 8 days were developed using the methodology provided in Regulatory Guide 1.109, " Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I",
Revision 1, October 1977, NUREG-0133,
" Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants", October 1978, and the atmospheric dispersion model presented in Information Recuested in to Letter from Georce Lear to E.
G.
Bauer dated February 17, 1976, September 30, 1976.
These equations provide for determing the actual doses based upon the historical average atmospheric conditions.
Compliance with the 10 CFR 50 limits for radiciodines, radioactive materials in particulate form and radionuclides other than noble gases with half lives greater than eight days is to be determined by calculating the thyroid dose from iodine-131 releases.
Since the iodine-131 dose accounts for 92 percent of the total dose to the thyroid, the value calculated is increased by nine percent to account for the dose from all other nuclides.
In the event that the plant is shutdown long enough so that iodine-131 is no longer present in gaseous effluents, an Isotopic Analysis Method is available.
Since no iodines are present, the critical organ changes from the thyroid to the liver.
APPENDIX A RADI0 ACTIVE EFFLUENTS CONTROLS PROGRAM CONTAINING OFFSITE DOSE CALCULATION MANUAL SPECIFICATIONS (0DCMS) AND BASES FOR PEACH BOTTOM ATOMIC POWER STATION i
UNITS 2 AND 3 REVISION 9 i
RADI0 ACTIVE EFFLUENTS CONTROLS PROGRAM TABLE OF CONTENTS 3.8.A Definitions
.................... ODCM 3.8.A-1 3.8.B Liquid Radwaste Effluents 00CM 3.8.B-1
'3.8.C
' Gaseous Effluents
....... ODCM 3.8.C-1 3.8.D 40 CFR 190.....
00CM E.8.0-1 3.8.E Radiological Environmental Monitoring
......... ODCM 3.8.E-1 3
3.9 Major. Changes to Radioactive Waste Treatment Systems... ODCM 3.9-1 3.10 Reporting Requirements.....
ODCM 3.10-1 B 3.8 ODCM Specifications Bases ODCM B 3.8-1 d
p PBAPS Units 2 and 3 ODCM 3.8 Revision 9
{
i
l Definitions 3.8.A ODCMS 3.8.A Definitions
.....................................N0TE-------------------------------------
The defined terms of this section appear in capitalized type and are applicable throughout these Offsite Dose Calculation Manual Specifications and Bases.
Term Definition FUNCTIONAL TESTS A FUNCTIONAL TEST is the manual operation or initiation of a system, subsystem, or component to verify that it functions within design tolerances (e.g., the manual start of a core spray pump to verify that it runs and that it pumps the required volume of water).
GASEOUS RADWASTE Any system designed and installed to reduce TREATMENT SYSTEM radioactive gaseous effluents by collecting primary coolant system offgases from the primary system and providing for delay or holdup for the purpose of reducing the total radioactivity prior to release to the environment.
INSTRUMENT CALIBRATION An INSTRUMENT CALIBRATION means the adjustment of an instrument signal output so that it corresponds, within acceptable range, and accuracy, to a known value(s) of the parameter which the instrument monitors. The known value of the parameter shall be injected into the instrument as close to the primary sensor as practicable.
INSTRUMENT CHECK An INSTRUMENT CHECK is a qualitative determination of acceptable OPERABILITY by observation of instrument behavior during operation. This determination shall include,. where possible, comparison of the instrument with other independent instruments measuring the same variable.
INSTRUMENT FUNCTIONAL TEST An INSTRUMENT FUNCTIONAL TEST means the injection of a simulated signal into the instrument as close to the primary sensor as practicable to verify the proper instrument response, alarm and/or initiating action.
(continued)
PBAPS Units 2 and 3 ODCM 3.8.A-1 Revision 9
~_
Definitions :
l 3.8.A ODCMS 3.8.A Definitions (continued)
MEMBERS OF~THE PUBLIC MEMBERS OF THE PUBLIC shall include all persons who are not occupationally associated with the plant. This category does not include employees of the utility, its contractors, or vendors. Also excluded from this category are persons who enter the site to service equipment or to make deliveries.
This category does include persons who use portions of the site for recreational, occupational, or other purposes not associated with the plant.
OFFSITE DOSE CALCULATION Contains the current methodology and parameters MANUAL used in the calculation of offsite doses due to radioactive gaseous and liquid effluents and describes the environmental radiological monitoring program.
OPERABLE - OPERABILITY A system, subsystem, division, component, or device shall be OPERABLE or have OPERABILITY when it is capable of performing its specified safety function (s) and all necessary attendant instrumentation, controls, normal and emergency electrical power, cooling and seal water, lubrication, and other auxiliary equipment that are required for the system, subsystem, division, component, or device to perform its specified safety function (s) are also capable of performing their related support function (s).
PURGE - PURGING PURGE or PURGING is the controlled process of discharging air or gas from a confinement to maintain temperature, pressure, humidity, concentration or other operating condition, in such a manner that replacement air or gas is required to purify the confinement.
SITE BOUNDARY That line beyond which the land is not owned, leased, or otherwise controlled by licensee as defined in Figure 3.8. A.1.
SOURCE CHECK A SOURCE CHECK shall be the qualitative assessment cf channel response when the channel sensor is exposed to a radioactive source.
PBAPS Units 2 and 3 ODCM 3.8.A-2 Revision 9
Definitions 3.8.A
)
j
\\,
REACTOR BLOC.
N
)
\\
.\\
\\
e ese see es.
1BBSINE BLBC.
j
-3 i
STAIIes s\\
MAIN
- 11 2 8 3 Aests. stes.
STACK
'y EL. 785:
g UNITS 2 (R,00FYENTS s'
t
)
s g
s
's./
unti t a
e s
M
/
LIQUID DISCHARGE
\\
STRUCTURE L
p
/<
~
\\
Figure 3.8.A.1 SITE BOUNDARY (including gaseous and liquid effluent release points) i e
PBAPS Units 2 and 3 OOCH 3.8.A-3 Revision 9
1 Liquid Radwaste Effluents :
l 3.8.B.1 3.8.B Liquid Radwaste Effluents ODCMS 3.8.B.1 The concentration of radioactive material released to areas at or beyond the SITE BOUNDARY shall be limited to-1 a.
The concentration specified in 10 CFR 20 Appendix B.
Table II, Column 2 for radionuclides other than noble l
gases: and b.
2 X 10'dgCi/mi total activity concentration for all dissolved or entrained noble gases.
APPLICABILITY:
At all times.
COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Concentration of A.1 Decrease the release Immediately radioactive material rate of radioactive released to areas at materials to restore or beyond the SITE concentration to BOUNDARY exceeding within limits.
limits.
08 A.2 Increase the dilution Immediately flow rate to restore concentration within limits.
08 A.3 Decrease the release Immediately rate of radioactive materials and increase the dilution flow rate to restore concentration within limits.
I PBAPS Units 2 and 3 ODCM 3.8.B-1 Revision 9
l Liquid Radwaste Effluents 3.8.B.1 ODCMS REQUIREMENTS ODCMS REQUIREMENT FREQUENCY ODCMS 4.8.B.1.1 Take a sample of each batch of liquid Prior to each effluent and analyze for the release concentration of each significant gamma energy peak.
Base the release rate on the circulating water flow rate at the time of discharge.
ODCMS 4.8.B.1.2 Record radioactive concentrations and During each volume before dilution of each batch release of liquid effluent released, the average dilution flow, and length of time over which each discharge occurred. These facility records shall be maintained.
ODCMS 4.8.B.1.3 Perform radioactive liquid waste In accordance sampling and activity analysis.
with Table 4.8.B.1 PBAPS Units 2 and 3 ODCM 3.8.B-2 Revision 9
Liquid Radwaste Effluents l
3.8.B.1 Table 4.8.B.1 (Page 1 of 2)
Radioactive Liquid Waste Sampling and Analysis SAMPLE TYPE SAMPLE SAMPLE SAMPLE LOWER LIMIT FREQUENCY ANALYSIS OF DETECTION (LLD)
(a).(d),(e)
Waste Tank to be Each batch (b)
Quantitative 5 X 107gCi/mi released Analysis of
- Identifiable Gamma Emitters I-131 1 X 10'gCi/ml Proportional Composite 31 days (c)
Fe-55 1 X 10'5gCi/ml of Batches Tritium 1 X 10~5gCi/ml Gross Alpha 1 X 10'7 Ci/ml Proportional Composite 31 days (c)
Sr-89 5 X 10-8gC1/ml of Batches Sr-90 5 X 10^8gCi/ml One Batch 31 days Dissolved 1 X 10~5gCi/ml noble gases (a)
The Sample Lower Limit of Detection is defined as an a priori (before the fact) limit representing the capability of a measurement system and not as an a posteriori (after the fact) limit for a particular measurement. The values for the lower limit of detection are based on a 95% confidence level.
(b)
A batch release is the discharge of liquid wastes of a discrete volume.
Prior to sampling for analysis, each batch shall be isolated and thoroughly mixed to assure representative sampling.
(c)
A composite sample is one in which the quantity of the sample is pro)ortional to the quantity of liquid waste discharged and in which the metlod of sampling results in a sample representative of the liquids released.
i PBAPS Units 2 and 3 ODCM 3.8.B-3 Revision 9 1
l
..?
Liquid Radwaste Effluents 3.8.8.1 Table 4.8.B.1 (Pa e 2 of 2)
Radioactive Liquid Waste S ling and Analysis (d)
The principal gamma emitters for which the minimum detectable level specification will apply are exclusively the following radionuclides:
Mn-54. Fe-59. Co-58. Co-60. Zn-65. Mo-99. Cs-134. Cs-137. Ce-141. and Ce-144. This list does not mean that only these nuclides are to be detected and reported.
Other peaks which are measurable and identifiable, together with the above nuclides, shall also be identified and-reported.
Nuclides which are below the sample detectable limit for the analyses should not be reported as being present at the sample detectable limit level. When unusual circ.imstances result in sample.
detectable limits higher than required, the reasons shall be documented in the Annual Effluent Report. The. values listed are believed to be l-attainable.
(e)
Certain mixtures of radionuclides may cause interarence in the measurement of individual radionuclides at their detectable limit especially if other radionuclides are at much higher concentrations.
Under these circumstances use of known ratios of radionuclides will be appropriate to calculate'the levels of such radionuclides.
i j
PBAPS Units 2 and 3 ODCM 3.8.B-4 Revision 9 I
Liquid Radwaste Effluents '
3.8.B.2,
'3.8.B Liquid Radwaste Effluents ODCMS 3.8 B.2 The dose or dose commitment to a MEMBER OF THE PUBLIC from
~
radioactive material in liquid effluent releases from the two reactors at the site to the areas at or beyond the SITE BOUNDARY shall be limited to:
a.
s 3.0 mrem to the total body and s 10.0 mrem to any organ during any calendar quarter: and b,
s 6.0 mrem to.the total body and s 20.0 mrem to any organ during any calendar year.
APPLICABILITY:
At all times.
COMPENSATORY MEASURES CONDITION lREQUIREDCOMPENSATORYMEASURE COMPLETION TIME A.
Calculated dose from A.1 Submit a Special 31 days the release of Report to the NRC radioactive materials that identifies in licuid effluents causes for exceeding exceecs required limit's, actions taken limits.
to reduce releases of radioactive materials in liquid effluents, corrective actions taken to assure-subsequent releases are within limits, results of radiological analyses of the drinking water source, and the radiological impact on the potentially affected drinking water supplies with regard to 40 CFR 141.
Safe Drinking Water Act.
PBAPS Units 2 and 3 ODCM 3.8.B-5 Revision 9
i Liquid Radwaste Effluents 3.8.B.2 ODCMS REQUIREMENTS 00 CMS REQUIREMENT FREQUENCY ODCMS 4.8.B.2.1 Determine cumulative dose 31 days contributions in accordance with the methodology and parameters in the ODCM.
PBAPS Units 2 and 3 00CM 3.8.B-6 Revision 9
I Liquid Radwaste Effluents '.
3.8.8.3 4
~
3.8.B Liquid Radwaste Effluents ODCMS. 3.8.B.3 The following conditions shall be met:
a.
Dilution water flow rates necessary to satisfy requirements of ODCMS 3.8.B.1 shall be maintained:
b.
The gross activity monitor and the flow monitor on the waste effluent line shall be OPERABLE: and c.
The liquid effluent control monitor shall be set in i
accordance with methodology and parameters in the ODCM to alarm and automatically close the waste discharge i
valve prior to exceeding limits in ODCMS 3.8.B.1.
I APPLICABILITY:
During release of radioactive wastes.
COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Gross activity monitor A.1 Initiate action to Immediately on the waste activity restore monitor to line inoperable.
OPERABLE status.
AND A.2 Analyze two Prior to release independent samples of tank's contents.
AND A.3 Perform independent Prior to release verification of the release rate calculations and discharge line valve line-up using at least two technically qualified members of the facility staff.
(continued)
PBAPS Units 2 and 3 ODCM 3.8.B-7 Revision 9
Liquid Radwaste Effluents 3.8.B.3 COMPENSATORY MEASURES (continued)
CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME B.
Flow monitor on the B.1 Initiate action to Immediately waste effluent line restore monitor to inoperable.
OPERABLE status.
AND i B.2
NOTE-------
Pump performance curves may be used to estimate flow.
Estimate waste 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> effluent line flow rate.
AND Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> thereafter l
C.
Required Compensatory C.1 Suspend release of Immediately I
Measures and radioactive effluents l
associated Completion
.via this pathway.
l
~ Time of Condition A or t
B not met.
08 Dilution water flow rates not satisfying requirements of-ODCMS 3.8.B.1.
1 l
D.
Liquid radwaste D.1 Explain the-reason Prior to effluents radiation the inoperability was submittal of the monitors inoperable not corrected in a next Annual i
for > 30-days.
timely manner in the Radioactive l
. Annual Radioactive Effluent Release Effluent Release Report Report.
(
l l
l PBAPS Units 2 and 3 ODCM 3.8.B-8 Revision 9 L
Liquid Radwaste Effluents-3.8.B.3' ODCMS REQUIREMENTS ODCMS REQUIREMENT FREQUENCY ODCMS 4.8.B.3.1 Perform INSTRUMENT CHECK of liquid 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> during radwaste effluents radiation monitor.
release ODCMS 4.8.B.3.2 Perform INSTRUMENT CHECK of liquid '
24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> during effluent flow monitor.
release ODCMS 4.8.B.3.3 Perform INSTRUMENT FUNCTIONAL TEST of 31 days liquid radwaste effluents radiation monitor, including OPERABILITY demonstration of the radwaste discharge automatic isolation valve and control room annunciation in i
response to alarm / trip setpoint being exceeded and an instrument INOP
)
failure.
J ODCMS 4.8.B.3.4 Perform SOURCE CHECK of liquid 92 days radwaste effluents radiation monitor.
1 ODCMS 4.8.B.3.5 Perform INSTRUMENT CALIBRATION of the 12 months liquid radwaste effluents-radiation monitor with a known radiation source positioned in a reproducible geometry with respect to the sensor.
ODCMS 4.8.B.3.6 Perform INSTRUMENT CALIBRATION of the 12 months liquid effluents flow monitor.
PBAPS Units 2 ar.d 3 ODCM 3.8 B-9 Revision 9
= ~
1 Liquid Radwaste Effluents 3.8.B.4 3.8.B Liquid Radwaste Effluents i
ODCMS 3.8.B.4 Liquid effluent releases shall be processed through one of l
the radwaste subsystems or combination of subsystems listed below:
a.
waste collector filter and demineralizer:
b.
floor drain filter:
c.
fuel pool filter demineralizer: or d.
chemical / oily waste cleanup subsystem APPLICABILITY:
Prior to all licuid effluent release (s) whenever the release (s) woulc cause the projected dose, when it is averaged over 31 days to exceed 0.12 mrem to the total body
)
or 0.4 mrem to any organ (combined total from the two reactors at the site).
COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME 1
A.
Liquid waste A.1 Submit a Special 31 days discharged without Report to the NRC required processing.
that includes an i
explanation of why liquid radwaste was discharged without required processing.
identification of any inoperable equipment or subsystems and the reason for the inoperability, the action taken to restore the inoperable equipment to OPERABLE status, and the action taken to prevent recurrence.
l l
PBAPS Units 2 and 3 ODCM 3.8.B-10 Revision 9
Liquid Radwaste Effluent's : 3 l 3.8.B.4 ODCMS REQUIREMENTS ODCMS REQUIREMENT FREQUENCY ODCMS 4.8.B.4.1 Project doses due to liquid effluent 31 days releases to areas at and beyond the SITE BOUNDARY in accordance with the methodology and parameters in the ODCM.
ODCMS 4.8.B.4.2 Demonstrate OPERABILITY of the waste 92 days collector filter and demineralizer and the floor drain filter by analyzing
~
the liquid processed through the subsystem and determining it meets the requirements of ODCMS 3.8.B.1.
ODCMS 4.8.B.4.3 Demonstrate OPERABILITY of the fuel Prior to pool filter demineralizer by analyzing release of the liquid processed through the liquid subsystem and determining it meets the effluents requirements of ODCMS 3.8.B.1.
processed by this subsystem ODCMS 4.8.B.4.4 Demonstrate OPERABILITY of the Prior to chemical / oily waste cleanup subsystem release of by analyzing the liquid processed liquid through the subsystem and determining effluents it meets the requirements of processed by 00 CMS 3.8.B.1.
this subsystem PBAPS Units 2 and 3 ODCM 3.8.B-11 Revision 9
Gaseous Effluents o
3.8.C.1 l
3.8.C Gaseous Effluents ODCMS 3.8.C.1 The dose rate at or beyond the SITE BOUNDARY due to radioactive materials in gaseous effluents released from the two reactors at the site shall be limited to the following:
a.
For noble gases, s 500 mrem per year to the total body i
.and s 3000 mrem per year to the skin; and i
b, For iodine-131, ~ iodine-133. tritium, and all radionuclides in particulate form with half lives
> 8 days, s 1500 mrem per year to any organ, APPLICABILITY:
At all times.
' COMPENSATORY MEASURES i
CONDITION REQUIRED COMPENSATORY MEASURE-COMPLETION TIME A.
Dose rates at or A.1 Decrease release Immediately beyond the SITE rates to comply with BOUNDARY exceed limits limits due to radioactive material in gaseous effluents.
1 00 CMS REQUIREMENTS ODCMS REQUIREMENT FREQUENCY i
00 CMS 4.8.C.1.1 Verify the dose rate due to noble In accordance gases in gaseous effluents is within with sampling limits in accordance with methods and and analysis procedures of the ODCH.
program specified in Table 4.8.C.1 (continued)
PBAPS Units 2 and 3 ODCM 3.8.C-1 Revision 9 c
"%r'~+--g:p.tw--
m mwe r
w-1-m.
e ym>--
w my
--u-p
%-e ra--
n
+r-mn--n---
vt,<
Gaseous Effluents ',
3.8.C.1 ODCMS REQUIREMENTS (continued)
ODCMS REQUIREMENT FREQUENCY ODCMS 4.8.C.1.2 Obtain representative samples and In accordance verify the dose rate due to with sampling iodine-131, iodine-133. tritium, and and analysis all radionuclides in particulate form program with half lives > 8 days in gaseous specified in effluents are within limits in Table 4.8.C.1 accordance with the methods and procedures of the ODCM.
P8APS Units 2 and 3 ODCM 3.8.C-2 Revision 9
Gaseous Effluents 3.8.C.1 Table 4.8.C.1 (page 1 of 2)
Radioactive Gaseous Waste Sampling and Analysis from Main Stack and Vent Stack
- SAMPLE TYPE SAMPLE SAMPLE ANALYSIS SAMPLE FREQUENCY LOWER LIMIT OF DETECTION (LLD)
(a)(d)
Grab Sample 31 days (b)
Quantitative analysis "1 X 10yCi/cc(c) of identifiable gamma emitters Grab Sample 92 days Tritium 1 X 10gCi/cc Charcoal Filters 7 days (c)
I-131 1 X 10 2yCi/cc(c)
Particulate 7 days (c)
Quantitative analysis 1 X 10 gC1/cc(c)
Filters of identifiable gamma emitters 2
I-131 1 X 10 gCi/cc(c) l l
Particulate 31 days Gross Alpha 1 X 10yCi/cc Filters l
(composite of l
weekly filters)
Particulate 31 days Sr-89 1 X 10'22gCi/cc Filters (composite of Sr-90 1 X 10'22yCi/cc I
weekly filters)
Noble Gas Monitor Continuously Noble Gas Gross S or 1 X 10f'6Ci/cc (f) l (Main Stack) y 1 X 10 Ci/cc (g) l Noble Gas Monitor Continuously Noble Gas Gross S or 1 X 10'6gCi/cc (Roof Vents) y PBAPS Units 2 and 3 ODCM 3.8.C-3 Revision 9 l
l
i Gaseous Effluents -
i 3.8.C.1
- Table 4.8.C.1 (page 2 of 2)
Radioactive Gaseous Waste Sampling and Analysis from Main Stack and Vent Stack *
(a)
The sample lower limit of detection is defined as an a priori (before the fact) limit representing the capability of measurement system and not as an a posteriori (after the fact) limit for a particular l
measurement. The values for the lower limit of detection are based on a f
95% confidence level.
(b)
Sam 311ng and analysis shall be performed following shutdown, startup or l
a tiermal power change exceeding 15% of rated thermal power within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> from a steady state condition unless (1) analysis shows that the L
. dose equivalent I-131 concentration in the primary coolant has not increased more than a factor of 3. and (2) the noble gas activity monitor shows that effluent activity has not increased by more than a l
factor of 3.
(c)
Samples shall be changed at least once per 7 days and analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after changing.
Sampling shall also be performed at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for at least 3 days following each shutdown. startup or thermal power change exceeding 15% of rated thermal l
power in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and analyses shall be com)leted within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> of changing. When samples collected-for 24 uurs are analyzed, the corresponding LLD may be increased by a factor of 10. This requirement does not apply if (1) analysis has shown that the dose equivalent I-131
-concentration in the primary coolant has not increased more than a factor of 3. and (2) the noble gas monitor shows that effluent activity has not increased more than a factor of 3.
(d)
Certain mixtures of radionuclides may cause interference in the measurement of individual radionuclides at their detectable limit especially if other radionuclides are at much higher concentrations.
Under these circumstances use of known ratios of radionuclides will be appropriate to calculate the levels of such radionuclides.
Nuclides w11ch are below the sample detectable limit for the analyses should not be reported as being present at the sample detectable limit level.
(e)
Until completion of Modification 5384, the Reactor Building Vent Exhaust Stacks shall be considered to be the Vent Stacks.
(f)
After completion of Modification 5386.
(g)
Until completion of Modification 5386.
1 PBAPS Units 2 and 3 ODCM 3.8.C-4 Revision 9
Gaseous Effluents 3.8.C.2 j
3.8.C Gaseous Effluents l
ODCMS 3.8.C.2 The air dose at or beyond the SITE BOUNDARY due to noble l
gases in gaseous effluents released from the two reactors at the site shall be limited to the following:
l a.
For gamma radiation s 10 mrad during any calendar l
quarter.
i l
b.
For beta radiation, s 20 mrad during any calendar quarter-1 c.
For gamma radiation, s 20 mrad during any calendar year:
and d.
For beta radiation s 40 mrad during any calendar year.
i l
APPLICABILITY:
At all times.
l l
l COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME l
j l
A.
Calculated air dose at A.1 Submit a Special 31 days l
or beyond the SITE Report to the NRC BOUNDARY from that identifies radioactive noble causes for exceeding gases in gaseous limits. corrective effluents exceeds actions taken to i
limits.
reduce the releases.
t and corrective l
actions to assure l
that subsequent releases are within l
' limits.
l l
PBAPS Units 2 and 3 ODCM 3.8.C-5 Revision 9
Gaseous Effluents '.
3.8.C.2 ODCMS REQUIREMENTS ODCMS REQUIREMENT FREQUENCY ODCMS 4.8.C.2.1 Determine cumulative dose 31 days contributions for noble gases in accordance with the methodology and parameters in the 0DCM.
t PBAPS Units 2 and 3 ODCM 3.8.C-6 Revision 9
.m l l J Gaseous Effluents 3.8.C.3 3.8.C Gaseous Effluents l
l ODCMS 3.8 C.3 The dose to a MEMBER OF THE PUBLIC at or beyond the SITE BOUNDARY from iodine-131, iodine-133 tritium and all radionuclides in particulate form, with half lives > 8 days, l
in gaseous effluents released from the two reactors at the site shall be limited to:
l a.
s 15 mrem during any calendar quarter: and b.
s 30 mnem during any calendar year.
APPLICABILITY:
At all times.
COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLET Q TIME A.
Calculated dose from A.1 Submit a Special 31 days the release of Report to the NRC iodine-131.
that identifies iodine-133 tritium causes for exceeding and radionuclides in limits, corrective
) articulate form, with actions taken, and 1alf-lives > 8 days in proposed corrective gaseous effluents actions to assure exceeds limits.
that subsequent releases are within
- limits, li o
i i
PBAPS Units 2 and 3 ODCH 3.8.C-7 Revision 9
Gaseous Effluents -
3.8.C.3 '
00 CMS REQUIREMENTS ODCMS REQUIREMENT FREQUENCY ODCMS 4.8.C.3.1 Determine cumulative dose 31 days contributions for iodine-131, iodine-133, tritium, and radionuclides in particulate form with half lives
> 8 days in accordance with the methodology and parameters in the ODCM.
i PBAPS Units 2 and 3 ODCM 3.8.C-8 Revision 9
L -l l*
Gaseous Effluents 3.8.C.4 3.8.C ~ Gaseous Effluents ODCMS 3.8.C.4 The following conditions shall be met:
l a.
Main stack dilution flow shall be = 10,000 cfm:
b.
One vent stack noble gas monitor and one main stack noble gas monitor shall be OPERABLE and set to alarm in accordance with the methodology and parameters in the j
ODCH:
l c.
One vent stack iodine filter and one main stack iodine filter and one vent stack particulate filter and one main stack particulate filter with their respective flow rate monitors shall be OPERABLE: and
)
d.
One vent stack flow rate monitor and one main stack flow rate monitor shall be OPERABLE and set to alarm in accordance with the methodology and parameters in the ODCM.
i
.....____________.....___.___ NOTE---------------------------
Until completion of Modification 5384. the vent stack noble gas monitors, filters, and flow rate monitors shall be considered to be the reactor building exhaust vent noble gas monitors, filters, and flow rate monitors, respectively.
APPLICABILITY:
During release of radioactive wastes.
4 PBAPS Units 2 and 3 ODCM 3.8.C-9 Revision 9
' Gaseous Effluent's *.
,1 3.8.C.4 COMPENSATORY MEASURES
NOTE------------------------------------
Separate condition entry is allowed for each instrument.
CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
One required' vent A.1 Collect two 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> stack noble gas independent grab monitor inoperable.
samples from the AND affected effluent QB release pathway.
Once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter One required main stack noble gas AND monitor inoperable, A.2
NOTE---------
Perform independent verification of the release rate calculations using at least two technically-qualified members of the facility staff.
Analyze grab samples-24 hours from from the affected time of release pathway for collection gross activity.
(continued)
PBAPS Units 2 and 3 ODCM 3.8.C-10 Revision 9
l 1
Gaseous Effluents 3.8.C.4 COMPENSATORY MEASURES (continuad)
CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME B.
One required vent B.1 Collect samples from Immediately stack iodine filter the affected effluent inoperable, release pathway continuously with 1
2 auxiliary sangling equipment such that One required vent each sample period stack particulate duration is filter inoperable.
approximately 7 days.
E AND
\\
l One required main B.2 Analyze collected 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after stack iodine filter -
samples.
end of each inoperable.
sampling period l
2 One required main stack particulate i
filter inoperable.
l C.
One required vent C.1 Estimate flow re'.e' 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> stack flow rate from the affected monitor inoperable.
effluent release AND E
Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> i
thereafter l
One required main stack flow rate monitor inoperable.
l D.
Main off-gas stack D.1 Initiate action to Immediately dilution flow re-establish main
< 10.000 cfm.
off-gas stack flow a 10.000 cfm.
(continued) l i
I L
PBAPS Units 2 and 3 ODCM 3.8.C-11 Revision 9 l
t
Gaseous Effluent's *.
3.8.C.4-COMPENSATORY MEASURES (continued)
CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME E.- One or more required E.1 Explain the reason Prior to radioactive gaseous inoperability was not submittal of effluent monitoring corrected in a timely next Annual instrumentation manner in the ~ Annual Radioactive channels inoperable Radioactive Effluent Effluent Release
(
for >-30 days.
Release Report.
Report L
t ODCMS REQUIREMENTS ODCMS REQUIREMENT FREQUENCY ODCMS 4.8.C.4.1 Perform INSTRUMENT CHECK of the vent 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />
~
stack and main stack noble gas radiation monitors.
ODCMS 4.8.C.4.2
NOTE------------------
The requirement to perform an INSTRUMENT CHECK of the reactor building exhaust vent sample flow rate i
monitors is only applicable until completion of Modification 5384.
Perform INSTRUMENT CHECK of the vent stack and the main stack flow rate 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> monitors, and the Unit 2 reactor building exha >t vent samole flow rate monitor.
ODCMS 4.8.C.4.3
NOTE-----------------
This requirement is only applicable until completion of Modification 5386.
Perform INSTRUMENT CHECK of the main 7 days stack sample flow rate monitor.
(Continued)
PBAPS Units 2 and 3 ODCM 3.8.C-12 Revision 9
Gaseous Effluents 3.8.C.4 ODCMS REQUIREMENTS (continued)
ODCMS REQUIREMENT FREQUENCY ODCMS. 4.8.C.4.4 Perform INSTRUMENT FUNCTIONAL TEST of 92 days the. vent stack and main stack noble gas radiation monitors, including control room alarm annunciation in response to alarm setpoint being exceeded and an instrument downscale failure.
ODCMS 4.8.C.4.5
NOTE-----------------
This requirement is only applicable until completion of Modification 5386.
Perform INSTRUMENT FUNCTIONAL TEST of 184 days the main stack sample flow line Hi/Lo pressure switches.
q (Continued) i i
I 4
PBAPS Units 2 and 3 ODCM 3.8.C-13 Revision 9
Gaseous Effluentt
- 3.8.C.4 '
?
ODCMS REQUIREMENTS (continued)
ODCMS REQUIREMENT FREQUENCY-18 months 00 CMS 4.8.C.4.6 Perform INSTRUMENT CALIBRATION of the vent stack and main stack noble gas AND radiation monitors with a known radioactive source positioned in a
NOTES-----
reproducible geometry with respect to
- 1. Only
.the sensor.
applicable to vent stack monitors until completion of Modification 5384.
- 2. Only -
applicable to main stack radiation monitors until completion of Modification 5386.
12 months (continued) l i
i PBAPS Units 2 and 3 ODCM 3.8 C-14 Revision 9
.o Gaseous Effluents
+-
3.8.C.4 ODCMS REQUIREMENTS (continued)
ODCMS REQUIREMENT.
FREQUENCY ODCMS 4.8.C.4.7 Perform INSTRUMENT CALIBRATION of the vent stack and main stack flow rate 18 months monitors.
AND
NOTES-----
- 1. Only applicable to ver,t stack flow monitors until completion of Modification 5384.
- 2. Only applicable to main stack flow rate monitors until completion l
of' Modification 5386.
i J
12 months (continued)
PBAPS Units 2 and 3 ODCM 3.8.C-15 Revision 9 l
~
Gaseous Effluents,
3.8.C.4
'I l
ODCMS REQUIREMENTS (continued)
ODCMS REQUIREMENT FREQUENCY ODCMS 4.8.C.4.8 Perform INSTRUMENT CALIBRATION of the 18 months vent stack and main stack iodine and particulate sample flow rate monitors.
AND
.....N0TES-----
- 1. Only applicable to vent stack sample j
flow rate monitors until completion of Modification j
5384.
j 1
- 2. Only applicable to main stack sample flow rate
' monitors until completion of Modification 5386.
12 months 00 CMS 4.8.C.4.9
NOTE-----------------
This requirement is only applicable until completion of Modification 5386.
Perform INSTRUMENT CALIBRATION of the 24 months main stack sam]le flow line Hi/Lo pressure swittles.
PBAPS Units 2 and 3 ODCM 3.8.C-16 Revision 9
L!'
Gaseous Effluents 3.8.C.5 3.8.C Gaseous Effluents ODCMS 3.8.C.5 Gaseous effluents shall be processed through the Gaseous Waste Treatment System described below prior to discharge:
a.
Steam jet air ejector discharge shall be processed through the recombiner, holdup pipe, off-gas filter, and off-gas stack; b.
Mechanical vacuum pump and gland steam exhauster discharge shall be processed through the off-gas stack:
c.
Reactor, turbine, radwaste, and recombiner building atmospheres shall be processed through permanently or temporarily installed equipment in the appropriate building ventilation system and the vent stack, with the exception of the following unmonitored exhausts:
- 1. Recirculation M-G set and reactor building cooling water equipment rooms:
l
- 2. Control room utility and toilet rooms:
- 3. Cable spread room:
- 4. Emergency switchgear rooms:
- 5. 125/250 VDC battery rooms and the 250 VDC battery rooms, and
- 6. Administration building maintenance decontamination l
area.
_____________________________ NOTE---------------------------
Until completion of Modification 5304, the Reactor Building Ventilation Exhaust Stacks shall be considered to be the Vent Stacks.
l i
APPLICABILITY:
At all times.
l d
1 i
PBAPS Units 2 and 3 ODCM 3.8.C-17 Revision 9 l
Gaseous Effluents.
3.8.C.5 COMPENSATORY MEASURES CONDITION RE0VIRED COMPENSATORY MEASURE COMPLETION TIME-A.
Gaseous waste A.1 Submit.a Special 31 days discharged without Report to the NRC.
required processing.
that. explains'the reasons gaseous radwaste was discharged without processing.
identifies inoperable equipment or subsystems and the reasons for the inoperability, identifies actions taken to restore the inoperable equipment to OPERABLE status, and actions taken to prevent a recurrence.
00 CMS REQUIREMENTS ODCMS REQUIREMENT FREQUENCY ODCMS 4.8.C.5.1 Project doses due to gaseous effluent 31 days releases at and beyond the SITE
~
BOUNDARY in accordance with the methodology and parameters in the ODCM.
ODCMS 4.8.C.5.2 Collect and analyze air samples from 31 days each building area with an unmonitored
- exhaust, i
(continued) i 1
PBAPS Units 2 and 3 ODCM 3.8.C-18 Revision 9
~
Gaseous Effluents 3.8.C.5 4
ODCMS REQUIREMENTS (continued)
ODCMS REQUIREMENT FREQUENCY i
00 CMS 4.8.C.S.3 Demonstrate OPERABILITY of required 92 days gaseous radioactive waste system equipment by analyzing the gaseous waste processed through the required equipment to determine it meets the requirements of ODCMS 3.8.C.1 i
2 i
PBAPS Units 2 and 3 ODCM 3.8.C-19 Revision 9
Gaseous Effluents -
3.8.C.6 '
3.8.C Gaseous Effluents ODCMS 3.8.C.6 PURGING of the primary containment shall be:
a.
Through the Standby Gas Treatment System whenever primary containment is required to be OPERABLE: and b.
Through the Reactor Building Ventilation Exhaust System or the Standby Gas Treatment System whenever primary containment is not required to be OPERABLE.
APPLICABILITY:
During PURGING of the primary containment.
COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Requirement of A.1 Suspend PURGING.
Immediately ODCMS 3.8.C.6 not met.
ODCMS REQUIREMENTS ODCMS REQUIREMENT FREQUENCY ODCMS 4.8.C.6.1 Verify primary containment PURGING is Prior to through required effluent release PURGING primary pathway of ODCMS 3.8.C.6.
containment PBAPS Units 2 and 3 ODCh 3.8.C-20 Revision 9 1
l-l-l- l 'l '
40 CFR 190 l'
3.8.D.1 i
3.8.D 40 CFR 190 ODCMS 3.8.D.1 The dose.or dose commitment to a MEMBER OF THE PUBLIC over the calendar year from all uranium fuel cycle sources within 1
8 kilometers shall be:
a.
s 25 mrem to the. total body or any organ (except the thyroid); and l
b.
s 75 mrem to the thyroid.
t APPLICABILITY:
At all times.
l COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Calculated dose to a
NOTE-------------
MEMBER OF THE PUBLIC Calculations shall include exceeds twice the direct radiation limits specified in contributions from reactor i
ODCMS 3.8.B.2 or units and outside storage l
ODCMS 3.8.C.2 or tanks.
ODCMS 3.8.C.3.
A.1 Calculate dose or Immediately dose commitment to a MEMBER OF THE PUBLIC from all uranium fuel l
cycle sources within 8 kilometers to determine if specified limits were exceeded.
(continued) i l
l PBAPS Units 2 and 3 ODCM 3.8.0-1 Revision 9 l
l-I
40 CFR 190,
3.8.D.1 COMPENSATORY MEASURES (continued)
CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME B.
Calculated dose or B.1
NOTE---------
dose commitment Estimates of exceeds specified radiation exposure limits of shall include the ODCMS 3.8.D.1.
effects of all effluent pathways and direct radiation including releases covered by this Special Report.
Submit a Special 31 days Report to the NRC that includes the corrective actions taken to prevent recurrence, the schedule for achieving conformance with required limits, estimates of radiation exposure to a MEMBER OF THE PUBLIC for the calendar year, descriptions of the levels of radiation and concentrations of radioactive material involved, and the cause of the exposure level or concentrations.
AND (continued)
PBAPS Units 2 and 3 ODCM 3.8.0-2 Revision 9 l
l.' /
40 CFR 190 3.8.D.1 COMPENSATORY MEASURES (continued)
CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME B.
(continued)
B.2
NOTES--------
- 1. Only applicable if the release condition resulting in violation of 40 CFR 190 has not been corrected.
- 2. Special Report submittal is considered a timely request and a variance is i
granted until NRC action on the request is complete.
Submit a request for 31 days a variance in aCCordance With 40 CFR 190 in the Special Report to the NRC.
ODCMS REQUIREMENTS ODCMS REQUIREMENT FREQUENCY ODCMS 4.8.D.1.1 Determine cumulative dose In accordance contributions from liquid and gaseous with ODCM effluents in accordance with methodology and parameters in the ODCM.
(continued)
PBAPS Units 2 and 3 ODCM 3.8.D-3 Revision 9
40 CFR 190 '.' ', ;
3.8.D.1 ODCMS REQUIREMENTS (continued)
ODCMS REQUIREMENT FREQUENCY ODCMS 4.8.D.1.2 Determine cumulative dose In accordance contributions from direct radiation with ODCM from the reactor units and from radwaste storage in accordance with s
methodology-and parameters in the ODCM.
PBAPS Units 2 and 3 ODCM 3.8.D-4 Revision 9
Radiological Environmental Monitoring 4.
3.8.E.1 3.8.E Radiological Environmental Monitoring i
ODCMS 3.8.E.1 Radiological environmental monitoring samples shall be collected at locations and analyzed as specified in i
Table 4.8.E.1 and the ODCM.
APPLICABILITY:
At all times.
I COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Milk samples A.1 Identify locations 31 days permanently for obtaining unavailable from any replacement samples 4
of.the sample and add them to locations listed in radiological a
the ODCM.
environmental monitoring program.
Delete locations from which samples are unavailable.
AND A.2 Identify in the Prior to Radioactive Dose submittal in Assessment Report the next Radioactive cause of the Dose Assessment unavailability of Report samples.and new locations for obtaining samples and include in the report revised figures and tables for the ODCM reflecting the new locations.
(continued) i PBAPS Units 2:and 3 ODCM 3.8.E-1 Revision 9 4
>n
Radiological Environrr ' al Monitoring '.'
3.8.E.1 COMPENSATORY MEASURES (continued)
CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME B.
Level of radioactivity B.1 Submit a Special 31 days after as a result of plant Report to the NRC end of affected effluents in an which includes an calendar quarter environmental sampling evaluation of any medium at one or more release conditions, locations specified in environmental the ODCM exceeds the factors, or other reaorting levels of aspects which caused Taale 3.8.E.1 when the reporting level averaged over the of Table 3.8 E.1 to calendar quarter.
be exceeded and the corrective actions to OR be taken to reduce radioactive effluents Level of radioactivity so that the potential as a result of plant annual dose to a effluents in an MEMBER OF THE PUBLIC environmental sampling is less than the medium at one or more calendar year locations specified in resorting level of the ODCM exceeds the Taale 3.8.E.1.
re)orting levels of Taale 3.8.E.1 when averaged over the calendar quarter and more than one radionuclide from Table 3.8.E.1 is detected and the equation in ODCMS 4.8.E.1.2 is satisfied.
(continued)
PBAPS Units 2 and 3 ODCM 3.8.E-2 Revision 9
l l '.'
Radiological Environmental Monitoring 3.8.E.1 COMPENSATORY MEASURES (continued)
CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME C.
Radionuclides other C.1
NOTE--------
than those in Only required if the Table 3.8.E.1 detected radionuclides and the potential detected are the annual dose to a result of plant MEMBER OF THE PUBLIC effluents.
l 1s greater than or equal to the calendar year limits of Submit a Special 31 days after ODCMS 3.8.B.2, or Report to the NRC end of affected j
ODCMS 3.8.C.2, or which includes an calendar quarter ODCMS 3.8.C.3, or evaluation of any 00 CMS 3.8.D.1.
release conditions, environmental factors, or other aspects which caused the reporting level of Table 3.8.E.1 to be exceeded: and the corrective actions to i
be taken to reduce radioactive effluents so that potential annual dose to a MEMBER OF THE PUBLIC is less than the calendar year re)orting level of Ta]le 3.8.E.1 AND 4
(continued)
I l
l i
i i
PBAPS Units 2 and 3 ODCM 3.8.E-3 Revision 9 I
Radiological Environmental Monitoring ',' <*
3.8.E.1 COMPENSATORY MEASURES CONDITION-REQUIRED COMPENSATORY. MEASURE COMPLETION TIME C.
(continued)
C.2
NOTE--------
Only required if the radionuclides detected are not the result of plant effluents.
Describe the Prior to condition in the submittal of Annual Radiological.
next Annual Environmental Radiological Operating Report.
Environmental Operating Report D.
Requirements of D.1 Prepare and submit.
Prior to ODCMS 3.8.E.1 not met.
in the Annual submittal of Radiological next Annual Operating Report, a Radiological description of the Environmental reasons for not Operating Report conducting the radiological environmental monitoring program as required and the actions taken to prevent recurrence.
1 4
4 PBAPS Units 2 and 3 ODCM 3.8.E-4 Revision 9
' ? 'l '
Radiological Environmental Monitoring 3.8.E.1 ODCMS REQUIREMENTS ODCMS REQUIREMENT FREQUENCY ODCMS 4.8.E.1.1
NOTES-----------------
- 1. Deviations are permitted from the required sampling schedule if specimens are unobtainable due to hazardous conditions, seasonal unavailabilities, malfunction of automatic sampling equipment or other legitimate reasons.
- 2. If equipment malfunction occurs, an effort shall be made to complete corrective actions prior to the end of the next sampling period.
Collect radiological environmental In accordance monitoring samples at the locations with and analyze as specified in Table 4.8.E.1 Table 4.8.E.1 and the ODCH.
l ODCMS 4.8.E.1.2
NOTE------------------
All radionuclides used in this evaluation shall be averaged on a calendar quarterly basis.
Evaluate the concentration of 92 days radioactivity as a result of plant effluents in an environmental sampling medium against the following equation:
concentration (1) reporting level (1) concentration (2)
+
reporting level (2)
... = 1.0 i
PBAPS Units 2 and 3 ODCM 3.8.E-5 Revision 9
Radiological Environmental Monitoring '.' ';
3.8.E.1 Table 3.8.E.1 (page 1 of 1)
Reporting levels for Radioactivity Concentration in Environmental Samples Reporting Levels ANALYSIS WATER
. AIRBORNE FISH MILK F000 PRODUCTS (pC1/1)
PARTICULATE OR (pCi/kg. wet)
(pC1/1)
(pCi/kg. wet) 3 GASES (pC1/m )
H3 20.000*
Mn-54 1.000 30.000 Fe 59 400 10.000 Co 58 1.000 30.000 Co 60 300 10.000 Zn 65 300 20.000 Zr-Nb-95 400 1-131 0.9 3
100 Cs 134 30 10 1.000 60 1.000 Cs 137 50 20 2.000 70 2.000 Ba La-140 200 300
' *For drinking water samples. This is 40 CFR part 141 value.
Il 1
4 l
1 1
l l
PBAPS Units 2 and 3 ODCM 3.8.E-6 Revision 9
-.n
Radiological Environmental Monitoring 3.8.E.1 Table 4.8.E.1 (page 1 of 3)
Radiological Environmental Monitoring Program EXPOSURE PATHUAY NUMBER OF SAMPLES AND SAMPLE LOCATION (a)
SAMPLING AND TYPE AND AND/OR SAMPLE COLLECTION FREQUENCY OF FREQUENCY ANALYSIS (b),(c) 1.
Direct At least 40 routine monitoring stations either Every 31 days Every 31 days Radiation (e) with two or more dosimeters or with one (Gamma dose) instrument for measuring and recording dose or rate continuously to be placed as follows: 1) or an inner ring of stations in the general area Every 92 days of the SITE BOUNDARY and an outer ring in the Every 92 days 3 to 6 mile range from the site. A station is (Ganna dose) in each sector of each ring except as dictated by local geography. The balance of the stations are in special interest areas such as population centers, nearby residences, schools and in areas to serve as control stations.
2.
Airborne Radiolodine and Samples from 5 locations:
Continuous Radiolodine Particulates sampler canisters a.
3 samples from close to the SITE BOUNDARY operation with I-131 analysis locations (in different sectors) of the sample every 7 days highest calculated annual average ground collection every level D/Q.
7 days or Particulate required by dust sampler: (f) b.
1 sample from the vicinity of a connunity
- loading, gross beta having the highest calculated annual whichever is radioactivity average ground level D/Q.
more frequent.
enalysis following c.
1 sample from a control location unlikely filter change; to be affected by the plant.
ganna isotopic analysis of composite (by location) 92 days 3.
Waterborne a.
Surface a.
1 sample upstream Composite (b)
Gamma isotopic sample over 31 (d) analysis b.
1 sanple downstream day period.
every 31 days.
Conposite for tritiun analysis at least every 92 days i
(continued)
PBAPS Units 2 and 3 ODCM 3.8.E-7 Revision 9 t
Radiological Environmental MonitorinQ '.' ',','
3.8.E.1 Table 4.8.E.1 (page 2 of 3)
Radiological Environmental Monitoring Program EXPOSURE PATHWAY NUMBER OF SAMPLES AND SAMPLE LOCATION SAMPLING AND TYPE AND AND/OR SAMPLE COLLECTION FREQUENCY OF FREQUENCY ANALYSIS (b),(c) 3.
Waterborne (cont'd)
- b. Drinking a.
1 sample of each of 1 to 3 of the nearest Composite (b)
Composite for water supplies that could be affected by sample over 31 gross beta and its discharge, day conposite gansna (d) period isotopic b.
1 sample from a control location.
analyses every 31 days.
Composite for tritium analysis at least every 92 days c.
Sediment 1 sample from downstream area with existing or Every 6 months Gansna isotopic from potential recreational value.
(d) analysis Shoreline every 6 months 4.
Ingestion
- a. Milk a.
Samples from milking animals in 3 Every 14 days Ganna isotopic locations within 3 miles distance having when animals are (d) analysis the highest dose potential, on pasture, or 134, 137 Cs every 31 days at by chemical b.
1 sample from milking animals at a other times.
separation control location (unlikely to be affected every 92 days.
by the plant).
1-131 analysis of each
- sample, b.
Fish a.
1 sanple of each connercially and Sanple in Ganna isotopic recreationally important species in sessen, or every (d) analysis vicinity of discharge point when 6 months if they on edible available.
are not portions.
- seasonal, b.
1 sanple of same species in areas not influenced by plant discharge when available,
- c. Food a.
Sa.nples of 3 different kinds of broad Every 31 days Gansna isotopic Products leaf vegetation grown nearest offsite when available (d) and 1 131 i
garden of highest annual average ground if milk sampling analysis level D/Q if milk sampling is not is not performed.
performed.
b.
1 sanple of each of the similar broad Every 31 days Ganna isotopic leaf vegetation grown 15 - 30 km distant when available (d) and I 131 in the least prevalent wind direction if if milk sampling analysis milk sanpling is not performed.
is not performed l
l PBAPS Units 2 and 3 ODCM 3.8.u-8 Revision 9 l
1
)
Radiological Environmental Monitoring 3.8.E.1 Table 4.8.E.1 (page 3 of 3)
Radiological Environmental Monitoring Program NOTES (a) Fixed sample locations are shown in the Offsite Dose Calculation Manual, Table VII.A.1 and Figures VII.A.1, Vll.A.2, and VII.A.3. At times it may not be possible or practicable to obtain samples of the media of choice at the most desired location or time. In those instances suitable alternative media and locations may be chosen for the particular pathway in question. Such necessary deviations are reported in the Annual Environmental Radiological Operating Report.
(b) Composite samples shall be collected by collecting an aliquot at intervals not exceeding 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
(c) Sample collection frequencies are defined as follows:
7 days 7 calendar days 1 2 days 14 days 14 calendar days 1 3 days 31 days 31 calendar days t 8 days 92 days 92 calendar days 10 days 6 months 6 calendar months 1 20 days (d) Gamma isotopic analysis means the identification and quantification of gamma emitting radionuclides that may be attributable to the effluents from the facility.
(e) Each phosphor is considered one thermoluminescent dosimeter.
(f) If the gross beta activity in air attributable to plant operation is greater than ten times the yearly mean of control samples, garrma isotopic analysis shall be performed on the individual samples.
l l
l PBAPS Units 2 and 3 ODCM 3.8.E-9 Revision 9 1
i
~.
Radiological Environmental Monitorin0 *.* 1,-
3.8.E.1
- Table 4.8.E.2 (page 1 of 1)
Maximum values for Minim m Detectable Levels of Activity (MDL)'d FISH MILK F000 PRODUCTS-SEDIMENT AIRSORNEPAR{)lCULATE ANALYSIS WATER (pcl/m (pci/kg, wet)
-(pCl/l)
(pCl/kg, wet)
(pCf/kg, dry)
(pci/l)
Gross geta 2.5
.006 3H 1200 54 Mn
'9 80 i
59 Fe.
18 160 58, 60 Co 9
80 65 Zn 18 160 95 Zr-Nb 9
.04 0.6 36 131-!
134, 137 9, 11
.04 90 10 40 100 Cs 140 Ba La 9
(a) Analyses shall be performed in such a manner that the stated ICLs Will be achieved under routine conditions et a 95% confidence level. Occasionally, background fluctuations, unavoidably small sample sizes, the presence of interfering nuclides or other uncontrollable circumstances make these MDLs unachievable.
J i
i i
i PBAPS Units 2 and 3 ODCM 3.8.E-10 Revision 9 1
1 2 '?
- Radiological Environmental Monitoring 3.8.E.2 3.8.E Radiological Environmental Monitoring i
ODCMS 3.8.E.2 A land use census shall be conducted and shall identify the location of the nearest milk animal in each of the 16 meteorological sectors within a distance of five miles.
l l
APPLICABILITY:
At all times.
L L
COMPENSATORY MEASURES I
CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Land use census A.1 Add the new location 31 days I
identifies a location to the radiological which yields a environmental calculated dose or monitoring program.
l dose commitment (via the same exposure AND pathway) that is at least 20% greater than l
a location from which samples are currently H
being obtained in accordance with ODCMS 3.8.E.1.
(continued) l l
l l
PBAPS Units 2 and 3 ODCM 3.8.E-11 Revision 9
Radiological Environmental Monitoring '.' 'l :
3.8.E.2 COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME l
A.
(continued)
A.2
NOTE---------
The indicator sampling location having the lowest calculated dose or dose commitment (via the same exposure pathway) may be deleted.from the radiological environmental monitoring program after October 31 of the year in which land use census was conducted.
Identify the new Prior to location in the submittal of the Radioactive Dose next Radioactive-Assessment Report and Dose Assessment include the revised Report figures and tables for the ODCM reflecting the new location.
B.
Land use census B.1 Identify the new Prior to identifies a location location in the submittal of the which yields a Radioactive Dose next Radioactive calculated dose or Assessment Report.
Dose Assessment dose commitment that Report is greater than values currently being calculated in ODCMS 3.8.C.3.
PBAPS Units 2 and 3 ODCM 3.8.E-12 Revision 9
, s...
Radiological Enviror. mental Monitoring 3.8.E.2 ODCMS REQUIREMENTS ODCMS REQUIREMENT FRE0VENCY ODCMS 4.8.E.2.1 Conduct a land use census by a door-12 mer:hs to-door survey or by consulting local agriculture authorities or by some other appropriate means.
i i
PBAPS Units 2 and 3 ODCM 3.8.E-13 Revision 9
Radiological Environmental Monitoring /' < <-
j 3.8.E.3 3.8.E ' Radiological Environmental Monitoring ODCMS 3.8.E.3 Analyses shall be performed on radioactive materials supplied as part of the EPA Environmental Radioactivity Intercomparison Studies Program, or another Interlaboratory Comparison Program approved by the NRC.
APPLICABILITY:
.At all times, COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME j
.A.
Requirements of A.1 Include corrective Prior to
'ODCMS 3.8.E.3 not met.
actions to prevent submittal of recurrence in the next Annual Annual Radiological Radiological Environmental Environmental Operating Report.
Operating Report i
ODCMS REQUIREMENTS ODCMS REQUIREMENT FREQUENCY ODCMS 4.8.E.3.1 Include a summary of the results of In accordance the~Interlaboratory Comparison Program with Technical in the Annual Radiological Specification Environmental Operating Report.
5.6.2 PBAPS Units 2 and 3 ODCM 3.8.E-14 Revision 9 1
I
-_~
i j 'l
- Major Changes to Radioactive Waste Treatment Systems 7,
3.9 3.9 Major Changes to Radioactive Waste Treatment Systems 00 CMS 3.9.1 The radioactive waste treatment systems are those systems described in ODCMS 3.8.B.3, 3.8.B.4. 3.8.C.4, and 3.8.C.S.
which are used to maintain control over radioactive materials in gaseous and liquid effluents.
ODCMS 3.9.2 Major changes to the radioactive waste systems shall be made by either of the following methods.
For the purpose of this Specification " major changes" is defined in ODCMS 3.9.3.
- a. Licensee initiated changes:
1.
Licensee initiated changes shall be reported to the NRC as part of the Modification Report required by 10 CFR 50.59. The discussion of each change shall contain:
- a. A summary of the evaluation that led to the determination that the change could be made in
~.
accordance with 10 CFR Part 50.59:
b.
Sufficient detailed information to totally support the reason for the change without benefit of Edditional or supplemental information, i
- c. A detailed description of the. equipment, j
components, and processes involved and the 1
interfaces with other plant systems:
d.
A comparison of the predicted releases of radioactive materials, in liquid and gaseous effluents and in solid wastes, to the actual releases for the period prior to when the changes are to be made:
l
- e. An estimate of the exposure to plant operating personnel as a result of the change: and-R f.
Documentation of the fact that the change was reviewed and found acceptable by the PORC.
- 2. The change shall become effective upon review and acceptance by both the PORC and NRB.
(continued)
PBAPS Units 2 and 3 ODCM 3.9-1 Revision 9
Major Changes to Radioactive Waste Treatment Systemt < -
3.9 '
>j 3.9 Major Changes to Radioactive Waste Treatment Systems ODCMS 3.9.2 (continued)
.b.
_ Commission initiated changes:
1.
The ap)licability of the change to the facility
+
shall 3e determined by the PORC after consideration of the facility design.
j 2.
The licensee shall provide the Commission with written notification of its determination of 4
i applicability including any necessary revisions to reflect facility design.
- 3. The change shall be reviewed by the NRB at its next i
regularly scheduled maeting.
4.
The change shall become effective on a date proposed by the licensee and confirmed by the Commission.
ODCMS 3.9.3
" Major Changes" to radioactive waste systems shall include i
the following:
i
- a. Changes in proce::s equipment. components, structures, and effluent monitoring instrumentation from those described in the Final Safety Analysis Report (FSAR) and evaluated in the staff's Safety Evaluation Report (SER):
- b. Changes in the design of radwr's treatment systems that significantly alter the chara.. eristics and/or quantities of effluents released from those previously considered in the FSAR and SER*
I
- c. Changes in system design which invalidate the accident analysis as described in the SER: and j
4 d.
Changes in system design that result in a significant increase in occupational exposure of operating personnel, i
PBAPS Units 2 and 3 ODCH 3.9-2 Revision 9 i
.s..
Reporting Requirements 3.10 3.10 Reporting Requirements ODCMS 3.10.1 Annual Radioloaical Environmental Ooeratina Reoort The Annual Radiological Environmental 0)erating Report shall be submitted in accordance with tie requirements of Technical Specification 5.6.2.
In addition to the requirements of Technical Specification 5.6.2 the Annual Radiological Environmental Operating Report shall include l
or reference from previous reports:
- a. - A summary description of the radiological environmental monitoring program including sampling methods for each sample type, size, and physical characteristics of each sample type, sample preparation methods, and measuring equipment used:
- b. At least two maps of all sampling locations keyed to a j
table giving distances and directions from the midpoint between reactor vents:
- c. Results of the land use censu.; required by-0DCMS 3.8.E.2: and d.
Results of the Interlaboratory Comparison Program and Tables 4.8.B.1 and 4.8.C.1 was not achievable. quired by discussion of all analyses in which the LLD re ODCMS 3.10.2 Radioactive Effluent Release Reoort The Radioactive Effluent Release Report shall be submitted in accordance with the requirements of Technical Specification 5.6.3.
In addition to the requirements of Technical Specification 5.6.3, the Radioactive Effluent Release Report shall include:
a.
Information for each class of solid waste (as defined by 10 CFR part 61) shipped offsite during the report period:
1.
Container volume:
2.
Total curie quantity (specify whether determined by measurement or estimate):
3.
Principal radionuclides (specify whether determined by measurement or estimate):
(continued) l PBAPS Units 2 and 3 ODCM 3.10-1 Revision 9
Reporting Requirements *.' *,'
- 3.10 3.10 Reporting Requirements ODCMS 3.10.2 Radioactive Effluent Release Recor_t (continued) 4.
Source of waste and processing employed (e.g.,
dewatered spent resin, compacted dry waste, evaporator Jottoms); and 5.
Type of container (e.g.. LSA, Type A. Type B. Large Quantity).
- b. A list and description of un)lanned releases from the site to areas at or beyond t1e SITE BOUNDARY of radioactive materials in gaseous and liquid effluents made during the reporting period.
- c. Changes made during the reporting period to the Offsite Dose Calculation Manual (00CM) and a list of new locations for dose calculations and/or environmental monitoring identified by the land use census required by ODCMS 3.8.E.2.
ODCMS 3.10.3 Radiation Dose Assessment Reoorts The radiation dose assessment reports shall be submitted within 120 days after January 1 of each year.
The Radiation Dose Assessment Report shall include an annual summary of hourly meteorological data collected over the previous year. This annual summary may be either in the form of an hour-by-hour listing on magnetic tape of wind speed, wind direction, atmospheric stability, and precipitation (if measured), or in the form of joint frequency distributions of wind speed, wind direction, and atmospheric stability, In lieu of submission with the first half year Radioactive Effluent Release Report, the licensee will retain this summary of required meteorological data on site in a file that shall be provided to the NRC upon request. This same report shall include an assessment of the radiation doses due to the radioactive liquid and gaseous effluents released from the unit or station during the previous calendar year. This i
same report shall also include. an assessment of the radiation doses from radioactive liquid and gaseous effluent to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY during the report period. All assumptions used in making these assessments (i.e.,
specific activity, exposure time and location) shall be included in these reports.
The meteorological conditions (continued)
PBAPS Units 2 and 3 ODCM 3.10-2 Revision 9
1
.S o
Reporting Requirements-3.10 3.10 Reporting Requirements ODCMS 3.10.3 Radiation Dose Assessment Reoorts (continued) concurrent with the time of release of radioactive materials in gaseous effluents (as determined by sampling frequency and measurement) shall be used for determining the gaseous pathway doses. Approximate methods are acceptable. The assessment of radiation doses shall be-performed in accordance with the Offsite Dose Calculation Manual (0DCM).
The Radiation Dose Assessment Report shall also include an assessment of radiation doses to the likely most exposed MEMBER OF THE PUBLIC from reactor releases and other nearby uranium fuel cycle sources (including doses from primary effluent pathways and direct radiation) for the previous calendar year to show conformance with'40 CFR Part 190.
Environmental Radiation Protection Standards for Nuclear Power Operation. Guidance for calculating.the dose
' contribution from liquid and gaseous effluents are given in Regulatory. Guide 1.109, Revision 1, October 1977.
If doses from plant effluents do not exceed twice the Appendix I limits, a statement to that effect shall constitute a 40 CFR 190 assessment.
PBAPS Units 2 and 3 ODCM 3.10-3 Revision 9
ODCM Specifications Baser *
- v -
B 3.8 C-B 3.8 ODCM SPECIFICATIONS BASES General It is expected that releases of radioactive material in effluents will be kept at small fractions of the limits specified in Section 20.106 of 10 CFR. Part
- 20. At the same time, the licensee is permitted the flexibility of operation, compatible with consideration of health and safety. to assure that.the public is provided a dependable source of power even under unusual operating conditions which may tem3orarily result in releases higher than such small fractions, but still wit 11n the limits saecified in Section 20.106 of 10 CFR. Part 20..It is expected that in using t11s operational flexibility under unusual operating conditions the licensee will exert his best efforts to keep levels of radioactive material in effluents as low as practicable.
Liouid Radwaste Effluents Concentration This specification is provided to ensure that the concentration of radioactive materials released in liquid waste effluents to areas at and beyond the SITE BOUNDARY will be within the concentration levels specified in 10 CFR. Part 20.
)
Appendix B. Table II. Column 2.
This instantaneous limitation provides additional assurance that the levels of radioactive materials in bodies of water in areas at or beyond the SITE BOUNDARY will result in exposures within (1) the Section II.A design objectives of Appendix I.10 CFR Part 50 to a MEMBER OF THE-PUBLIC and (2) the limits of 10 CFR Part 20.106(e) to the population. The concentration limit for noble gases is based upon the assumption that Xe-135 is the controlling radioisotope and its MPC in air (submersion) was converted to an equivalent concentration in water using the International Commission on Radiological Protection (ICRP) Publication 2.
Dose This specification is provided to implement the requirements of Sections II.A.
III.A and IV.A of Appendix I. 10 CFR Part 50.
ODCMS 3.8.B.2 im31ements the guidance set forth in Section II.A of Appendix I and provides tie required operating flexibility to im)lement the guides set forth in Section IV.A of Appendix I to assure thct t1e releases of radioactive material in liquid effluents will be kept "os low as reasonably achievable." The dose calculations in the ODCM implement the requirements in Section III.A of Appendix I that conformance with the guides of Appendix I be shown by calculational 3rocedures based on models and data such that the actual exposure of a iEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated. The ecuations described in the Offsite Dose Calculation Manual for calculating the coses due to the actual release rates (continued)
PBAPS Units 2 and 3 ODCM B 3.8-1 Revision 9
- 3~
ODCM Specifications Bases B 3.8 BASES Liauid Radwaste Effluents Dose (continued) of radioactive materials in liquid effluents are consistent with the methodology 3rovided in Regulatory Guide 1.19. " Calculation of Annual Doses J
- to Man from Routine Releases of Reactor Effiuents for the Purpose of Evaluating Compliance with 10 CFR Part 50. Appendix I." Revision 1. October 1977 and Regulatory Guide 1.113. "Estimat'ng Aquatic Dispersion of Effluents from Accidental and Routine Reactor Reletses for the Purpose of Implementing Appendix I " April 1977. This specification applies to the release of liquid effluents from the site.
Instrumentation The radioactive liquid effluent instrumentation is provided to monitor and control as applicable. the releases of radiosctive materials in liquid effluents during actual or potential release of liquid effluents. The OPERABILITY and use of this instrumentation is consistent with the requirements of General Design Criteria 60. 63. and 64 of Appendix A to 10 CFR Part 50.
System Operation The OPERABILITY of the Liquid Radwaste Treatment System ensures that this system will be available for use whenever liquid effluents require treatment prior to release to the environment. The requirement that the appropriate portions of this system be used when specified provides assurance that the releases to radioactive materials in liquid effluents will be kept "as low as reasonably achievable." This specification implements the requirements of 10 CFR. Part 50.36a. General Design Criterion 60 of Appendix A to 10 CFR. Part 50 and design objective Section II.D of Appendix I to 10 CFR Part 50. The specified limits governing the use of appropriate portions of the Liquid Radwaste Treatment System were specified as a suitable fraction of the guide set forth in Section II.A of Appendix I.10 CFR. Part 50, for liquid effluents.
The chemical / oily waste cleanup subsystem may include the portable Epicor oil / water emulsion system (as described in RW-625), an installed chemical / oily waste cleanup subsystem or equivalent chemical / oil waste system.
(continued)
PBAPS Units 2 and 3 ODCM B 3.8-2 Revision 9
ODCM Specifications Bases '.' ;'
- B 3.8 BASES (continued)
Gaseous Effluents Dose This specification is provided to ensure that the dose from radioactive materials in. gaseous effluents at and beyond the SITE BOUNDARY will be within the annual dose limits of 10 CFR Part 20.
The annual dose limits are the doses associated with the concentrations of 10 CFR Part 20. Appendix B. Table II, Column 1.
These limits provide reasonable assurance that radioactive material discharged in gaseous effluents will not result in the exposure of a MEMBER OF THE PUBLIC. either within or outside the SITE BOUNDARY. to annual average concentrations exceeding the limits specified in Appendix B. Table II of 10 CFR part 20.106(b).
For MEMBERS OF THE PUBLIC who may at times be within the SITE BOUNDARY the occupancy will usually be sufficiently low to compensate for any increase in the atmospheric diffusion factor above that for the SITE BOUNDARY.
Examples of calculations for such MEMBERS OF THE PUBLIC with the appropriate occupancy factors are given in the ODCM.
The specified limits restrict, at all times, the gamma and beta dose rates above background to a MEMBER OF THE PUBLIC, at or beyond the SITE BOUNDARY to s 500 mrem / year to the total body or to s 3000 mrem / year to the skin. These dose rate limits also restrict, at all times, the corresponding thyroid dose rate above background to a child via the inhalation pathway to s 1500 mrem / year.
Dose. Noble Gases This specification is provided to implement the requirements of Sections II.B.
III.A and IV.A of Appendix I. 10 CFR Part 50.
ODCMS 3.8.C.2 implements the guidance set forth in Section II.B of Appendix I and provides the required operating flexibility to im)lement the guides set forth in Section IV.A of Appendix I to assure that t1e releases of radioactive material in gaseous effluents will be kept "as low as reasonably achievable." ODCMS 4.8.C.2.1 implements the requirements in Section III.A of Appendix I that conformance with the guidance of A]pendix I be shown by calculational procedures based on models and data such t1at the actual exposure of a MEMBER OF THE PUBLIC through the appropriate pathways is unlikely to be substantially underestimated.
The dose calculations established in the ODCM for calculating the doses due to the actual release rates of radioactive noble gases in gaseous effluents are consistent with the methodology provided in Regulatory Guide 1.109 " Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR 50.
Ap]endix I " Revision 1. October 1977 and the atmospheric dispersion model suamitted on September 30, 1976, in a report titled:
"Information Requested in Enclosure 2 to letter from George Lear to E. G. Bauer dated February 17.
1976." The ODCM equations provided for determining the air doses at and beyond the SITE BOUNDARY are based upon the historical average atmospheric conditions.
(continued)
PBAPS Units 2 and 3 ODCM B 3.8-3 Revision 9
i S
ODCM Specifications Bases
~
B 3.8 l
l BASES Gaseous Effluents (continued)
Dose - Iodine-131. Tritium and Radionuclides in Particulate Form This specification is provided to implement the requirements of Sections II.C.
l III.A and IV.A of Appendix I. 10 CFR Part 50. ODCMS 3.8.C.3 imalements the I
guidance set forth in Section II.C of Appendix I and provides tie required operating flexibility to im31ement the guides set forth in Section IV.A of Appendix I to assure that tie releases of radioactive materials in gaseous effluents will be kept "as low as reasonably achievable." The ODCM calculational methods specified in the ODCMS 4.8.C.3.1 implements the requirements in Section III.A of Appendix I that conformance with the guides of Appendix I be shown by calculational procedures based on models and data such that the actual exposure of a MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated. The ODCM calculational methods for calculating the doses due to the actual release I
rates of the subject materials are consistent with the methodology provided in Regulatory Guide 1.109 " Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50. Appendix I," Revision 1, October 1977 and the Atmospheric Dispersion Model submitted on September 30, 1976 in a report titled:
"Information Requested in Enclosure 2 to letter from George Lear to E. G.
Bauer dated February 17, 1976." These equations also provide for determining the actual doses based upon the historical average atmospheric conditions.
The release rate specifications for iodine-131. tritium, and radionuclides in particulate form with half lives greater than 8 days are dependent on the existing radionuclide pathways to man in the areas at and beyond the SITE BOUNDARY. The pathways that were examined in the development of these calculations were:
- 1) individual inhalation of airborne radionuclides, 2) deposition of radionuclides onto green leafy vegetation with subsequent consumption by man, 3) deposition onto grassy areas where milk animals and meat producing animals graze with consumption of the milk and meat by man, and
- 4) deposition on the ground with subsequent exposure of man.
Instrumentation j
The radioactive gaseous effluent instrumentation is provided to monitor and l
control, as applicable the releases of radioactive materials in gaseous j
l effluents during actual or potential releases of gaseous effluents.
The OPERABILITY and use of instrumentation is consistent with the requirements of General Design Criteria 60, 63, and 64 of Appendix A to 10 CFR Part 50.
(continued) 1 1
i l
PBAP its 2 and 3 00CM B 3.8-4 Revision 9
ODCM Specifications Bases '.' ;*
- B 3.8 BASES Gaseous Effluents (continued)
System Operation The OPERABILITY of the Gaseous Radwaste Treatment System ensures that this system will be available for use whenever gaseous effluents require treatment prior to release to the environment.
The requirement that appropriate portions of this system be used when specified provides reasonable assurance that the releases of rMicactive materials in gaseous effluents will be kept "as low as is reasonably achievable." This s]ecification implements the requirements of 10 CFR. Part 50.36a. General Design Criterion 60 of Appendix A i
to 10 CFR Part 60 and design objective Section II.D of Appendix I to 10 CFR. Part 50. The specified limits governing the use of appropriate portions of the Gaseous Radwaste Treatment System were specified as a suitable fraction of the guidance set forth in Section II.B and II.C of Appendix I 10 CFR. Part
- 50. for gaseous effluents.
Containment PURGE ODCMS 3.8.C.6 requires that the primary containment atmosphere receive treatment for the removal of gaseous iodine and particulates prior to release to provide reasonable assurance that PURGING operations will not result in exceeding the annual dose limits of 10 CFR Part 20 for areas at or beyond the SITE BOUNDARY.
40 CFR 190 This specification is provided to meet the dose limitations of 40 CFR Part 190 that have now been incorporated into 10 CFR Part 30. This s)ecification requires the preparation and submittal of a Special Report w1enever the calculated doses from plant radioactive effluents exceed twice the design objective doses of Appendix 1.
It is highly unlikely that the resultant dose to a MEMBER OF THE PUBLIC Will exceed the dose limits of 40 CFR Part 190 if the individual reactors remain within the reporting requirement level. The Special Report will describe a course of action that should result in the limitation of the annual dose to a MEMBER OF THE PUBLIC to within the 40 CFR Part 190 limits.
For the pur)oses of the Special Report, it may be assumed that the dose commitment to tie MEMBER OF THE PUBLIC from other uranium fuel cycle sources is negligible, with the exception that dose contributions from other nuclear fuel cycle facilities at the same site or within a radius of 8 kilometers (km) must be considered.
If the dose to any MEMBER OF THE PUBLIC is estimated to exceed the requirements of 40 CFR Part 190. the Special Report with a request for a variance (provided the release conditions resulting in violation of 40 CFR Part 190 have not already been corrected), in accordance with the provisions of 40 CFR Part 190.11 and 10 CFR Part 20.405c. is (continued)
PBAPS Units 2 and 3 ODCM B 3.8-5 Revision 9
ODCM Specifications Bases 7
i B 3.8 BASES Gaseous Effluents i
40 CFR 190 (continued) considered to be a timely request and fulfills the requirements of 40 CFR Part.
190 until NRC staff action is completed.
The variance only relates to the limits of 40 CFR Part 190, and does not apply in any way to the other requirements for dose limitation of 10 CFR Part 20.
An individual.is not considered a MEMBER OF THE PUBLIC during any period in which he/she is engaged in carrying out any operation that is part of the nuclear fuel cycle.
Radiolooical Environmental Monitorina i
Monitoring Program The radiological environmental monitoring program required by this specification provides measurements of radiation and of radioactive materials in those exposure pathways and for those radionuclides, which lead to the highest potential radiation exposures of MEMBERS OF THE PUBLIC resulting from the two reactors at the sites. This monitoring program implements Section i
IV.B.2 of Appendix I to 10 CFR Part 50 and supplements the radiological l
effluent monitoring program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and the modeling of the environmental exposure pathways.
The required detection capabilities for environmental sample analyses are tabulated in terms of the Minimum Detectable Level (MDL).
The MDL's required by Tables 4.8.B.1 and 4.8.C.1 of the. specifications are considered optimum for routine environmental measurements in industrial laboratories..The monitoring program was developed utilizing the experience of the first seven years of commercial operation.
Program changes may be initiated based on the additional operational experience.
L Land Use Census This specification is provided to ensure that significant changes in the use L
of areas at and beyond the SITE BOUNDARY are identified and that modifications to the radiological environmental monitoring program are made if required by the results of this census. This census satisfies the requirements of Section IV.B.3 of Appendix I to 10 CFR Part 50.
(continued) l l
l 4
e 4
l
'PBAPS Units 2 and 3 ODCM B 3.8-6 Revision 9
ODCM Specifications Bases * '.44
'B 3.8 i
BASES Radioloaical Environmental Monitorina (continued).
Interlaboratory Comparison Program The requirement-for aarticipation in-an Interlaboratory Comparison Program is provided to ensure t1at independent checks on the precision and accuracy of the measurements of radioactive material in environmental sample matrices, are performed as part of the quality assurance program for environmental monitoring..in order to demonstrate that the results are reasonably valid for the purposes of Section IV.B.2 of Appendix I to 10 CFR Part 50.
l
.PBAPS Units 2 and 3 ODCM B 3.8-7 Revision 9
- 4 Effective Date RW-C-100, Rev. 2 N
Page 1 of 11 TRB/trb PORC YES PECO Energy Company SQR' YES Nuclear Generation Group NQA NO 50.59 YES RESP MGR YES SOLID RADWASTE SYSTEM PROCESS CONTROL PROGRAM ( PQE.1.
1.0 PURPOSE 1.1 This program provides guidance and boundary conditions for preparation of specific procedures for processing, sampling, analysis, packaging, storage and shipment of solid radwaste in accordance with State and Federal Regulatory requirements.
l CM-1 l 2.0 RESPONSIBILITY NOTE:
The station operating organization is outlined in each station's UFSAR.
2.1 PORC is responsible for reviewing all revisions to the PCP.
2.2 The Plant Manager is responsible for approving all revisions to the PCP.
~
2.3 The Nuclear Quality Assurance Department performs audits to verify compliance with the Nuclear Quality Assurance Program.
2.4 The Manager-Radwaste is responsible for:
2.4.1 Compliance with this Process Control Program.
2.4.2 Record keeping and document control of shipping and processing data.
2.4.3 Assuring the Radwaste personnel are appropriately trained and qualified.
2.4.4 Coordinating reviews and revisions to this document and corresponding implementing procedures.
2.4.5 Reviewing and revising this PCP and its implementing procedures.
2.4.6 Submitting revisions to the PCP for inclusion in the NRC Annual Radioactive Effluent Release Report.
m
.b 0
RW-C-100, Rev. 2 Page 2 of 11 2.5 The Sr. Manager-operations is responsible for:
2.5.1 Providing trained personnel to operate appropriate permanent radwaste process equipment.
2.5.2 Defining those Operations positions which require training.
2.6 The Director-Training is responsible for:
2.6.1 Development and implementation of training for designated personnel in.accordance with Nuclear Training Division procedures.
3.0 PREREOUISITES-3.1 The solid radioactive waste system shall be used in accordance with the PCP.
CM-1 3.2 Processing of solid radioactive waste shall be performed by qualified and trained personnel.
Training records for operators of mobile vendor processing units shall be maintained by the Manager, Radwaste while the vendor is active on-site.
3.3 Vendor services may be used for dewatering and solidification of radioactive waste processing provided the services are governea by a Topical Report and referenced in this PCP.
Processing of radioactive waste by on-site vendors shall be performed in accordance with applicable Topical Report, procedures and NRC guidance.
When providing solidification for stabilization, the vendor shall have an NRC approved topical report.
3.4 The Topical Reports of vendor supplied Radwaste Processing Systems shall undergo review by the Manager, Radwaste (or designee).
The review shall ensure the vendor supplied i
system will be compatible with plant operations.
The review shall be performed in accordance with RW-C-106.
3.5 On-site processing of radioactive waste shall be performed in accordance with approved station procedures.
3.6 Quality Assurance shall be maintained as defined by the.
Nuclear Quality Assurance Plan.
l 4.0-PRECAUTIONS 4.1 Changes to the PCP shall be submitted to the Nuclear Regulatory Commission in the Annual Radioactive 3ffluent Release Report for the period in which the change was made, 4.2 Changes to resin dewatering implementing procedures or c
i systems shall require verification that the free standing water content of the packaged product is within established i
regulatory limits.
1
?
I RW-C-100, Rev. 2 A
Page 3 of II 4.3 Prior to revising or deleting a PCP implementing procedure, the preparer shall review the procedure against the PCP to ensure that there is no compromise or conflict.
4.4 Prior to modification to an in plant liquid Radwaste Processing System, the individual responsible for the MOD shall review to ensure that it is not in conflict with or compromises the PCP.
4.5 When processing does not meet storage requirements or shipping and transportation requirements, processing shall be suspended and the PCP reviewed for adequacy.
The implementing procedures and/or the Solid Waste System shall be corrected as necessary to prevent recurrence.
I 5.0 APPARATUS
]
None 6.0 PROCEDURE l
6.1 PROCESS DESCRIPTIONS i
NOTE:
Vendor services may be used to process any radioactive waste I
stream provided the services are performed with an j
acceptable Process Control Program.
6.1.1 Waste Sources (For diagrams of the Solid Radwaste Systems, see UFSAR 11.4 for LGS and 9.2 and 9.3 for PBAPS.
Also refer to MOD 1750A for PBAPS).
i 1.
Condensate Filter /Demineralizer Waste a.
Condensate Filter /Demineralizer Waste is the waste product generated by the backwash of the condensate filter /demineralizers consisting of:
- 1) contaminated powdered ion exchange resins at varying degrees of exhaustion, fibrous filter media, and small concentrations of various solids and corrosion products for the precoatable element system, and
- 2) iron oxide and small concentrations of various other solids for the precoatless element system (LGS).
b.
A condensate filter /demineralizer backwash consists of approximately:
- 1) 9,000 gallons of slurry for the precoatable element system, and
- 2) 3,000 gallons of slurry for the precoatless element system (LGS).
c.
Backwashes are collected and settled in a Condensate Phase Separator.
Clarified liquid is decanted until sufficient volume of settled spent resin and crud is obtained for processing.
RW-C-100, Rev 2
Page 4 of 11 d.
Phase' separator contents are recirculated prior to transfer to the Dewatering System, Slurry input to the Dewatering System is e.
transferred to the system from the phase separators via the-sludge mixing pumps.
4 2.
Condensate Deep Bed Demineralizer Waste (Limerick Only) a.-
Condensate Deep Bed Demineralizer waste is the waste product generated by the. backwash of the condensate deep bed demineralizers. consisting of contaminated ion exchange bead resins at varying degrees of exhaustion and-small concentrations of various solids and corrosion products.
b.
Each condensate deep bed demineralizer backwash consists of approximately 2,800 gallons of slurry.
c.
Each backwash contains 320 cubic feet of resin and is collected in an empty Spent Resin Receiver Tank.
d.
During normal operations the Spent Resin Receiver Tank contents will be transferred to the Floor and Equipment Drain deep bed demineralizers for reuse.
e.
Resins'that are determined unacceptable for reuse or excess will be processed from-the 1A Spent Resin Receiver Tank using vendor dewatering.
f.
The 1A Spent Resin Receiver Tank Contents.are recirculated for a minimum of.25 minutes to mix contents of the vessel, resulting-in a homogeneous resin' slurry.
l g.
The solids slurry is then fed to the External Processing Station for dewatering.
3.
Waste Sludge-Tank Waste a.
Waste Sludge Tank Waste is the waste product generated by the backwash of the liquid radwaste and fuel pool filters and demineralizers consisting of contaminated powdered ion exchange-resins and bead resins at varying degrees of exhaustion, fibrous filter media, carbon overlay material and small concentrations of various solids and corrosion products.
b.
Backwashes from radwaste filter /demineralizers, radwaste deep bed demineralizers, and fuel pool filter /demineralizers'are collected in the Waste Sludge Tank.
F 4
+-n,--
i RW-C-100, Rev. 2 A
Page 5 of 11 l
c.
A backwash from a radwaste filter consists of l
approximately 1,925 gallons of slurry (PB) or l
1,500 gallons (LGS).
d.
A backwash from the radwaste deep bed demineralizer consists of approximately 1,500 gallons of slurry.
e.
At Peach Bottom, the Waste Sludge Tank contents are transferred to a Condensate Phase Separator i
for processing.
From the Condensate Phase Separators, waste is processed using a Dewatering System.
f.
At LGS, Waste Sludge Tank contents may be processed directly to the Dewatering System or transferred to a condensate phase separator for processing, g.
Tank contents are recirculated prior to transfer to the Dewatering System.
4.
Reactor Water Cleanup Waste a.
Reactor Water Cleanup waste is the wasta product generated by the backwash of the Reactor Water Cleanup filter demineralizers consisting of contaminated powdered ion exchange resins at 4
varying degrees of exhaustion, fibrous filter media, and small concentrations of various solids and corrosion products, b.
A RWCU filter-demineralizer backwash consists of approximately 1,100 gallons of slurry, c.
Btckwashes are collected and settled in a phase separator.
Clarified liquid is decanted until sufficient volume of settled spent resin and crud is obtained for processing.
d.
Phase separator contents are recirculated prior to transfer to the Dewatering System.
5.
Oily Waste a.
Sludges and oils generated during operation and maintenance are collected in containers in appropriate approved areas throughout the plant.
The filled and labeled containers are sealed and j
moved to available areas for temporary staging.
b.
Sludges / oils may be decontaminated to below station free release limits and processed as
(
non-radioactive waste.
c.
Sludges / oils may be shipped off-site for processing / incineration.
RW-C-100, Rev. 2 Page 6 of 11 A
6.
Miscellaneous Waste a.
Certain wet wastes may be allowed to dry and be treated as dry active waste or filters.
6.2 WASTE STREAM PROCESSING 6.2.1 Dewaterina i
1.
Resin processing is normally performed using a Dewatering System.
a.
The Dewatering System shall be operated in accordance with the system's Topical Report and applicable procedures.
b.
The Dewatering System processes resin by using equipment described by the Topical Report to remove free standing water, c.
Dewatered resin is packaged in appropriately selected liners or High Integrity Containers based on waste classification.
d.
Station to Dewatering System interfacing is addressed by an approved 10 CFR 50.59 Review.
6.2.2 Solidification 1.
Resins, sludges and oily wastes may be solidified by a Mobile Solidification System.
a.
The Mobile Solidification System shall be operated in accordance with the system's Topical Report and applicable procedures.
b.
The Mobile Solidification System processes waste using equipment described by the Topical Report to remove free standing liquid.
c.
Solidified waste is packaged in appropriately selected containers based on waste classification.
d.
Station to Mobile Solidification system interfacing shall be addressed by an approved 10 CFR 50.59 Review.
]
6.2.3 Decontamination 1.
Decontamination of oil may be performed on-site using a vendor service.
The service shall be performed in accordance with the applicable 10 CFR 50.59 Review.
RW-C-100, Rev. 2 N_
Page 7 of 11 6.3 PRODUCT CONTROL 6.3.1 Routine sampling is performed by one of two techniques:
1.
Direct sample from each batch.
These samples are analyzed for activity and isotopic identity.
If radionuclide distributions are shown to be consistent between similar batches, consideration may be given to decreasing the frequency of routine measurements.
This constitutes routine sampling QB 2.
Dose rate reading taken from a container of waste.
Dose rates are converted to activity and isotopic breakdown based on annual samples.
6.3.2 Scaling factors for nuclides which are hard to identify are established for waste by analysis through an off-site vendor.
Frequency of sanpling is on an annual basis as a minimum.
6.3.3 Tests are performed on-site quarterly, as a minimum, to-verify scaling factors.
If the tests indicate that the scaling factors obtained through annual samples have changed by more than a factor of ten, consideration shall be given to increased off-site analysis.
6.3.4 When plant parameters affecting waste stream isotopics are' altered (ex., fuel failure),. consideration shall be given to
-further waste stream sampling.
6.3.5 Administrative controls for preventing unsatisfactory waste forms from being released for shipment are described in applicable station. procedures.
If the provisions of the PCP are not satisfied, then suspend shipments of defectively packaged solid radioactive' waste from the site.
CM-1 6.3.6 Liquid wastes or wastes containing liquids shall be converted to a form that contains as little free standing and non-corrosive liquid as is reasonably achievable.
The liquid shall not exceed 1% of the volume of the waste, or 0.5% of the waste volume for solidified waste, 6.3.7 Processed resin is tested annually as a minimum to verify the free standing water content of the packaged product is within applicable regulatory limits.
In addition to the annual verification, the free standing water content is determined whenever process changes occur that may significantly alter system performance.
Tests are performed to verify operability and for ensuring the waste form is similar to that indicated in prequalification testing.
6.3.8 To prevent accumulation of radiolytically generated combustible gas in greater than Type A radioactive waste packages containing water and/or organic substances, one or more of the following measures are taken:
1.
The container is equipped with a vent to prevent accumulation of such gas.
l RW-C-100, Rev. 2 Page 8 of 11 k
2.
A determination by calculation, test, or measurement is performed to ensure.that hydrogen generation is limited to a molar quantity that would be no more than 5% by volume of the secondary container gas void at standard temperature and pressure (STP) over a period of time that is twice.the expected shipment time.
3.
The cask cavity will be inerted.
6.3.9 Sufficient analyses shall be performed to verify that the quality-of waste forms prepared for disposal by vendor's-on-site processing shall be similar to vendor's test results.
6.4 WASTE CHARACTERISTICS FOR LAND DISPOSAL The following are minimum requirements _for all classes of waste and are intended to facilitate handling at the disposal site, provide protection of health and safety of personnel at the disposal site,. and ensure that wet. radioactive wastes are processed to meet shipping and burial ground requirements:
CM-1 6.4.1.
Waste shall not be' packaged for disposal in cardboard or fiberboard containers.
6.4. 2 '
Waste shall not be readily capable of detonation or of explosive decomposition or reaction at normal pressure and
' temperatures, or of explosive reaction with water.
6.4.3 Waste shall not contain, or be capable of generating, quantities of toxic gases, vapors,.or fumes harmful to persons transporting, handling, or disposing of the waste.
- 6. 4. 4 '
Waste shall not be pyrophoric.
Pyrophoric materials contained in the waste shall be treated, prepared, and packaged to be nonflammable.
6 4.5 Waste-containing hazardous,' biological, pathogenic or infectious material shall be handled in a manner that minimizes the potential hazard from the non-radiological materials.
6.4.6 Each waste shipment shall be accompanied by a shipping L
manifest giving a physical description of the waste, the volume, the radionuclide identity and quantity, the total i
radioactivity, the principal chemical form, and waste class.
6.5 WASTE STABILITY The following requirements are intended to provide stability and are applicable to Class B and Class C wastes:
]
i l
6.5.1 Waste shall have structural stability which can be provided j
by the waste form itself, processing the waste to a stable form, or placing the waste in a disposal container or structure that provides stability.
-r-
.v e-r.
c-r-e
+ + - -, - -
3 w--
-e-,
m.--=-*.m.
w
~~
<v--wr
- - - - - e
-y w-w-
.s RN-C-100, Rev. 2 A
Page 9 of 11 6.5.2 Void spaces within the waste and its package should be reduced to the extent practicable.
6.5.3 Waste requiring stabilization is normally packaged in approved High Integrity Containers (HIC).
The HICs are handled and stored in accordance with the applicable certificate of Conformance (C of C).
Upon arrival at the burial site, Class B and C wastes are placed in concrete overpacks for structural stability.
6.6 SURVEILLANCE REQUIREMENTS FOR SOLIDIFICATION Perform the following prior to the shipment of solidified radioactive waste from the site:
CM-1 6.6.1 At least one representative test specimen from at least every tenth batch of waste shall be solidified.
6.6.2 If any test specimen fails to verify solidification, the solidification of the batch under test shall be suspended until additional test specimens can be obtained, alternative solidification parameters can be determined and a subsequent test verifies solidification.
6.6.3 If the initial test specimen from a batch of waste fails to verify solidification, representative test specimens from consecutive batches shall be tested until at least three consecutive test specimens demonstrate solidification.
The solidification process control program shall be modified as required to assure solidification of subsequent batches.
6.7 QUALITY ASSURANCE PROGRAM 6.7.1 Quality Assurance shall be maintained as defined by the Nuclear QA Plan.
6.7.2 Audits by personnel independent of the activities are performed and reviewed by appropriate management personnel.
6.7.3 Administrative controls for preventing unsatisfactory waste forms from being released for shipment are described in applicable station procedures.
6.7.4 Procedures are reviewed to ensure compliance with the requirements and process parameters of this PCP.
6.7.5 Radioactive wastes not described within this document shall be evaluated for inclusion in this PCP or in a vendor Process Control Program prior to processing.
6.8 REVISIONS 6.8.1 Revisions to the PCP shall be approved in accordance with applicable station or Common Nuclear Generation Group Procedures.
4 Rh-C-100, Rev. 3 Page 10 of 11 4
6.8.2 Any changes to the Solid Radwaste Process Control Program shall be submitted for input to the Annual Radioactive Effluent Release Report.
6.9 DOCUMENTATION 6.9.1 Records of all data, tests, analysis results, and records of training, inspection, and audits are maintained in accordance with applicable procedures.
6.9.2 Waste classification records, waste form records, and other records required for the preparation of the Annual Radioactive Effluent Release Report shall be prepared and retained in accordance with the requirements of 10CFR20, 10CFR71, 49CFR170-178, and Station Technical Specifications.
6.9.3 Sufficient documentation shall be maintained to demonstrate compliance with this PCP.
l
7.0 REFERENCES
7.1 SOURCE DOCUMENTS 7.1.1 Low Level Waste Licensing Branch Technical Position on Waste Form.
7.1.2 Low Level Waste Licensing Branch Technical Position on Waste Classification.
7.1.3 Limerick Generating Station Unit 1 and 2 Technical Specifications, 6.5.1.6, 6.8.1, 6.13.
7.1.4 Updated Final Safety Analysis Report Peach Bottom Atomic Power Station Units 2 and 3, and Limerick Generating Station Units 1 and 2.
l 7.1.5 PBAPS Technical Specifications Section 5.6.3.
l 7.1.6 PBAPS ODCMS 3.9.3.
7.1.7 49 CFR Parts 170 through 178.
7.1.8 10 CFR Parts, 20, 50, 61, and 71.
7.1.9 Standard Review Plan 11.4, including Branch Technical Position ETSB11-3.
7.1.10 Pacific Nuclear: NuPac Services Topical Report for Dewatering System TP-02-P-A.
7.1.11 General Criteria for High Integrity Containers (SCDHEC).
7.1.12 Westinghouse-Hittman Nuclear, Incorporated (SEG) Topical Report STD-R-05-011NP-A for Mobile In Container Dewatering and Solidification System (MDSS).
f RW-C-100, Rev. 2 A
Page 11 of 11 j
I 7.1.13 CM-1, Letter from G. A.
Hunger, Jr. dated Sept. 29, 1994 i
transmitting TSCR 93-16 (Reference A/R A0905923, E02) l 1
7.2 CROSS REFERENCES 7.2.1 RW-C-106, Review of Vendor Topical Report for Waste Processing 7.2.2 PCP Implementing Procedures 1
NOTE:
PCP Implementing Procedures are those which apply directly l
to processing, packaging, sampling, analyzing, and shipping radwaste.
1.
Limerick and Peach Bottom Radwaste Procedures (RW) or Applicable Common Procedure.
2.
Limerick and Peach Bottom Surveillance Test Procedures i
(ST) and Routine Test Procedures (RT).
3.
Limerick System (S) and Peach Bottom System Operating (SO) Procedures.
l 7.2.3 A-C-930, Radwaste and Radioactive Material QA Program 7.2.4 Generic Letter 89-01 (Implementation of Programmatic Controls for Radiological Effluent Technical Specifications in the Administrative Controls Section of the Technical i
Specifications and the Relocation of Procedural Details of RETS to the Off-site Dose Calculation Manual or to the Process Control Program), 1/31/89.
7.2.5 Off Site Dose Calculation Manual l
7.2.6 Limerick and Peach Bottom Chemistry Procedures or Applicable Common Procedures.
7.2.7 Safety Evaluation for Oil Decontamination, MOD 1259A (Peach Bottom only).
7.2.8 Safety Evaluation for MOD 1750A, Radwaste Dewatering Facility Peach Bottom Atomic Power Station (Peach Bottom only).
7.2.9 NRC Generic Letter 91-02, " Reporting Mishaps Involving LLW Forms Prepared for Disposal.
7.2.10 PECO 10CFR50.59 Review for Scientific Ecology Group Dewatering System Operation.
7.2.11 I.E.
Circular 80-18, 10CFR50.59 Safety Evaluation for Changes to Radioactive Waste Treatment Systems.
8.0 ATTACHMENTS None