ML20107H118
| ML20107H118 | |
| Person / Time | |
|---|---|
| Site: | University of Utah |
| Issue date: | 03/29/1996 |
| From: | Slaughter D UTAH, UNIV. OF, SALT LAKE CITY, UT |
| To: | |
| Shared Package | |
| ML20107H101 | List: |
| References | |
| PROC-960329, NUDOCS 9604240035 | |
| Download: ML20107H118 (4) | |
Text
_
I 4
l Univer'Aty of Utah Center for Excellence in Nuclear Technolgy Engineering and Research Reactor Operation Requalification Plan for NRC License R-126: TRIGA Nuclear Reactor (Docket No. 50-407) l Revision 1: 28 February 1996 Previous Plan Dated i
1 March 1994
)
i Prepared by David M. Slaughter / Reactor Supervisor University of Utah CENTER i
Salt Lake City, Utah 84112 l
i
)
1 l
9604240035 960329 i
PDR ADOCK 05000407 V
)
i I. Purpose This document sets forth the requirements for the Reactor Operator RequaliGcation Program for the University of Utah's TRIGA Research Nuclear Reactor (R126) in accordance 'vith the 10CFR55.59. The purpose of the requalification training program is to ensure that all operations personnel maintain proficiency at a level equal to or greater than that required for initiallicensmg.
- 11. Schedule A complete requalification training program will be offered biennially. The program consists of lectures, on the job training, and written, oral and console evaluations. The classroom retraining includes eight different lectures to be offered at least once during the biennium. The evaluations will be conducted annualh, Each operator will be required to perform shift duties for at least four hours during each quarter.
Each operator licensee will complete the program biennially. The licensee will enter the requalification program on the date the Nuclear Regulatory Commission issues either a new license or a renewal of an existing license. The licensee will continue in the requalification 3rogram until either the expiration date of the current license or the date at which the current y
.acense is terminated.
7 Ill. Lectures The lecture program will cover the following eight topics which will be offered at least once during the training period:
Topic:
Esfacart l
A. Nuclear Reactor Theory Standard Nuclear Engineering Text B. Radiation Control and Safety 10 CFR 20, RSP C. Goveming Regulations 10 CFR 19,50,55,70 D. Reactor Design SAR E. Reactor Control and Safety Systems SAR, AMF 4
F. Reactor Operating Characteristics SAR,AEF G. Normal, Abnormal and Eme.rgency STL, SL, ML, CL, FL, EP, PSP Operating Procedures
- 11. Technical Specifications and License ATS, R-126 License Each lecture will include a brief review of the last Reactor Safety Committee Meeting minutes with an emphasis on approved changes to CENTER procedures. All of the ML entries since the preceding lecture will also be reviewed. These frequent updates will ensure that all operators are properly infomied of all CENTER activities. Any operator may be assigned to present a lecture.
- Lectures shall reference the followinviocuments: Code of Federal Regulations (CFR), CENTER Safety Analysis Report (S AF), CENTER Author >ation for Experimental Facilities (AMF), CENTER Administrative and Technical Specifications (ATS), CENTER Emergency Plan (EP) and the University of Utah Physical Security Plan (PSP), Radiation Safety Program (RSP), Surviellance Log (SL), Start-up and Termination Log and Procedures (STL), Corr, Log (CL), Maintinence Log (ML)and Fuel Log (FL).
[
IV. On the Job Training A. Each operator will perform licensed functions for at least four hours per quarter to satisfy 10CFR55.53(e).
B. Each operator will demonstrate familiarity with the following activities at least once during the biennial period.
- 1. Pre-start checks
- 2. Start-up
- 3. Termination C. Each Senior Operator will perform or directly supervise the completion of all the above activities with the same frequency required of an operator.
V. Evaluations The ability of the operator to perfonn licensed duties will be determined by annual evaluation. The evaluations will include written and console examinations. These examinations may be administered in any order, at any time during the year, and on different dates.
A. Written Examinations:
The written examination will be administered as an open book exam in a controlled area. The operators may only use the CENTER operator's manual, as well as paper, pencils, erasers and calculators to complete the exam. The content of the examinations will satisfy the requirements of 10CFR55.41 and may include the requirements of 10CFR55.43. The Reactor Supervisor and the Facility Director will be responsible for preparing, administering and grading the written exam, on an alternating yearly basis, for all other licensed operators. The Director and the Reactor Supervisor will prepare, administer and grade each others written examinations biennially.
B. Console Examinations:
Each operator and senior operator will demonstrate familiarity with the following operator activities during the console examination:
- 1. Pre-start checks
- 2. Start-up
- 3. Operational Power
- 4. Tennination The console examinations are required only during those years in which Reactor operation is possible. Console examinations may be evaluated by any senior operator. Every licensee will participate in the console examination.
C. Grading:
The criteria for grading and the assignment of pass / fail are as follows:
- 1. The Written Examination The licensee will be assigned a rating of either SATISFACTORY or UNSATISFACTORY. In order to obtain a rating of SATISFACTORY, the licensee must attain a minimum score of 70% in each section of the examination. If the licensee fails to attain a rating of I
i l
i s
e
+.
S ATISFAGORY, that licensee will be removed from his licensed duties and enrolled in an accclerated training program in the deficient area, or areas.
- 2. Console Examination The licensee will be assigned a rating of either S ATISFACTORY or UNS ATISFACTORY. In order to obtain a rating of S ATISFACTORY, the licensee should demonstrate an understanding of the operation of all apparatus and mechanisms. This evaluation is based upon the ease and smoothness with which the operator performs the Pre-start, Start up, power operation and termination. If the licensee fails to attain a rating of SATISFACTORY, the licensee will be removed from his licensed duties and enrolled in an accelerated training program in the deficient area or areas.
VI. Operator Reinstatement:
An operator may be removed from active status by failing to actively perform the functions of an operator for a period of more than three months or by failing to obtain a satisfactory grade on an evaluation exam.10CFR55.53 (f) outlines the requirements for operator reinstatement.
If an operator has not actively performed the functions of an operator for a period of more than three months he shall satisfactorily demonstrate his competence before resuming his duties. This is accomplished by performing at least six hours oflicensed functions under the direction of a licensed operator or senior operator. Upon completion of this activity, the operator will be certified for operation by the Reactor Supervisor.
If an operator has failed to attain a satisfactory grade on any evaluation, he shall demonstrate his competence before resuming his duties. This is accomplished by the operator participating in all additional training in the area of the deficiency.
VII. Records:
A record will be maintained for each licensee and will contain a current copy of either the licensee's reactor operator or senior reactor operator's license, copies of all written examinations administered to thelicensee during the Requalification Period, or the licensee's requalification program progress checklist form NEL-025 (see appendix.) This fonn will contain a record of attended lectures, on the job training, written and console examination evaluations, a record of operator reinstatement, and medical examination completion date. Additional fonns may be kept in the licensee's record to provide supporting documentation and may include medical examination forms (10CFR55.53 (i))
and license applications or renewals.
)
'i
, -. -