R. F. Burski Onecor ro A u Sa'ety V2llerfud 3 W3F1-95-0182 A4.05 PR November 14, 1995 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 3ubject:
Waterford 3 SES Docket No. 50-382 License No. NPF-38 Monthly Operating Report I
Gentlemen:
Attached is the subject monthly report which covers the operating statistics for the month of October, 1995. This report is submitted per Section 6.9.1.6 of the Waterford 3 Technical Specifications for Facility j
Operating License No. NPF-38.
t Very truly yours, R.F. Burski Director Nuclear Safety RFB/DFL/ssf Attachment cc:
L.J. Callan, NRC Region IV C.P. Patel, NRC-NRR R.B. McGehee N.S. Reynolds F. Yost (Utility Data Institute, Inc.)
J.T. Wheelock (INP0 Records Center)
P G O * 0A NRC Resident Inspectors Office
[/ '
9511200010 951031 PDR ADDCK 05000382 l
R..
_ PDR
NRC MONTHLY OPERATING REPORT
SUMMARY
OF OPERATIONS WATERFORD 3 for October, 1995 The unit was in Refueling Outage #7 for the entire month, thus generating no power for the time-period.
l l
l l
inu ew.:i r.
~
i PRESSURIZER SAFETY VALVE FAILURES AND CHALLENGES WATERFORD 3 for October, 1995 There were no pressurizer safety valve failures or challenges experienced during the month, i
J 4
p h
(
inn
- r. 2 or.
OPERATING DATA REPORT DOCKET NUMBER :
50-382 UNIT NAME :
WATERFORD 3 DATE OF REPORT :
November 3, 1995 COMPLETED BY :
D. S. Freeman TELEPHONE :
(504) 464-3352 OPERATING STATUS
- 1. Reporting Period October, 1995 Gross Hours in Reporting Period 745
- 2. Currently Authorized Power Level (MWt) :
3,390 Maximum Dependable Capacity (Net MWe) :
1,075 Design Electrical Rating (Net MWe) :
1,104
- 3. Power Level to which Restricted (if any) (Net MWe) :
N/A
- 4. Reason for Restriction (if any)
N/A THIS YEAR TO MONTH DATE CUMULATIVE
- 5. Number of Hours Reactor was Critical 0.0 5,912.7 74.635.5
- 6. Reactor Reserve Shutdown Hours 0.0 0.0 0.0
- 7. Hours Generator was On-line 0.0 5.892.8 73,737.1
- 8. Unit Reserve Shutdown Hours 0.0 0.0 0.0
- 9. Gross Thermal Energy Generated (MWH) 0 19,919,377 244,248,986
- 10. Gross Electrical Energy Generated (MWH) 0 6,630,410 81,364,870
- 11. Net Electrical Energy Generated (MWH) 0 6,336,926 77,579.292
- 12. Reactor Service Factor 0.0 81.0 84.3
- 13. Reactor Availability Factor 0.0 81.0 84.3
- 14. Unit Service Factor 0.0 80.8 83.3
- 15. Unit Availability Factor 0.0 80.8 83.3
- 16. Unit Capacity Factor (using MDC) 0.0 80.8 81.5
- 17. Unit Capacity Factor (using DER) 0.0 78.7 79.3
- 18. Unit Forced Outage Rate 0.0 7.3 3.5 W3M Page ' 3 of 6
1
(
OPERATING DATA REPORT DOCKET NUMBER :
50-382 UNIT NAME :
WATERFORD 3 DATE OF REPORT :
November 3, 1995 COMPLETED BY :
D. S. Freeman TELEPHONE :
(504) 464-3352 OPERATING STATUS (Cont.)
- 19. Shutdowns Scheduled over next 6 months (type, date and duration of each) :
NONE
- 20. If Shutdown at end of report period, estimated date of startup:
11/6/95
- 21. Unit is in Commercial Operation.
THIS YEAR T0 f
MONTH DATE CUMULATIVE
- 22. Hours in Reporting Period 745 7,296 88,561
- 23. Unit Forced Outage Hours 0.0 463.0 2,673.2
- 24. Nameplate Rating (Gross MWe) :
1.200 Max. Dependable Capacity (Gross MWe) :
1,120
- 25. If changes occur in capacity ratings (Items 2 and 24) since the last report, give the reasons :
N/A 1
I IV19%
Page 4 of 6
t AVERAGE DAILY UNIT POWER LEVEL DOCKET NUMBER :
50-382 UNIT NAME :
WATERFORD 3 DATE OF REPORT :
November 3, 1995 COMPLETED BY :
D. S. Freeman TELEPHONE :
(504) 464-3352 Reporting Period :
October, 1995
( NET MWe )
DAY Avg. Power Level DAY Avg. Power Level l
1 (14) 16 (10) 2 (14) 17 (6) 3 (14) 18 (6) 4 (14) 19 (5) 5 (14) 20 (3) 6 (14) 21 (8) 7 (14) 22 (9) 8 (10) 23 (9) 9 (7) 24 (6) 10 (5) 25 (5) 11 (5) 26 (9) 12 (8) 27 (12) 13 (10) 28 (10) l 14 (10) 29 (8) 15 (10) 30 (9) 31 (21) l INSTRUCTIONS :
On this form, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.
nw r : 5 a.
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NUMBER :
50-382 UNIT NAME :
WATERFORD 3 DATE OF REPORT :
November 3, 1995 COMPLETED BY :
D. S. Freeman TELEPHONE :
(504) 464-3352 REPORTING PERIOD :
October, 1995 Date
- Duration
- Shutdown Cause, Comments and Number (yymmdd)
Type (Hours)
Reason Method Corrective Actions 95-02 950922 S
745.00 C
4 Unit removed from service to begin Refuel Outage 7.
Outage is continued from the previous period.
TYPE REASON F - Forced A - Equipment Failure (explain)
S - Scheduled B - Maintenance or Test C - Refueling D - Regulatory Restriction E - Operator Training and METHOD License Examination 1 - Manual F - Administrative 2 - Manual Scram G - Operational Error (explain) i 3 - Automatic Scram H - 0ther (explain) 4 - Continuation from Previous Period 5 - Power Reduction i
6 - Other (explain)
I I L'19%
Page 6 of 6