ML20086S705

From kanterella
Jump to navigation Jump to search
Informs That Licensee Has Reviewed 1994 & 1995 Entries to Encl to Ref 1 Ltr & Determines That Licensee Has Made Addl Proprietary Submittals to Support Design Certification for Sbwr
ML20086S705
Person / Time
Site: 05200004
Issue date: 07/31/1995
From: Quinn J
GENERAL ELECTRIC CO.
To: Quay T
NRC (Affiliation Not Assigned), NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
MFN-138-95, NUDOCS 9508020091
Download: ML20086S705 (4)


Text

n

i N
y i

GENuclearEnergy S

4$$s"$$itS$siAi!$)"

4 July 31,1995 MFN 138-95 Docket STN 52-004 Document Control Desk U. S. Nuclear Regulatory Commission Washington DC 20555 Attention: Theodore E. Quay, Director Standardization Project Directorate

Subject:

SBWR - REVIEW OF PROPRIETARY INFORMATION

Reference:

1.

Letter from D. M. Crutchfield (NRC) to J. E. Quinn (GE),

same subject, dated April 12,1995 2.

Letter MFN 110-95, J. E. Quinn (GE) to T. E. Quay (NRC), Same subject. dated July 19,1995.

GE has reviewed the 1994 and 1995 entries to the enclosure 'to the Reference 1 letter and determined that there are additional proprietary submittals that GE has made to support design certification for the SBWR. We have completed our review of the 1994 and year-to-date 1995 submittals covering the period since the realignment of the project to deal with Testing and TRACG before resuming the design related activities. The results of that review are provided in the Attachment to this letter.

Sincerely.

- ~ -s James E. Quinn

Attachment:

List of SBWR Proprietary Submittals to the NRC,1995 and 1994 cc:

P. A. Boehnert (NRC/ACRS) (2 paper copies w/att. plus E-Mail w/att.)

l-

1. Catton (ACRS)

(1 paper copy w/att. plus E-Mail w/att.)

S. Q. Ninh (NRC)

(2 paper copies w/att. plus E-Mail w/att.)

J. II. Wilson (NRC)

(1 paper copy w/att. plus E-Mail w/att.)

Of n ' n n 4.s 9508020091 950731 PDR ADDCK 05200004

\\\\

A PDR

- N --

l f

Attachment to MFN 138-95 SBWR PROPRIETARY SUBMITTALS TO THE NRC i

1995 l

t DATE MFN NO.

SUBJECT 1.

1/18/95 003-95 NRC Requests for Additional Information on the Simplified Boiling Water Reactor (SBWR) Design (RAI 950.23) 2.

1/19/95 006-95 NRC Requests for Additional information on the Simplified Boiling Water Reactor (SBWR) Design (RAI 950.51 AND 950.52) 3.

2/6/95 014-95 Meeting Summary of 1/9 and 1/11/95 4.

2/27/95 034-95 NRC Requests for Additional Information on the Simplified Boiling Water Reactor (SBWR) Design RAls 901.52-901.72 Related to Licensing Topical Reports (NEDE-32176P, NEDE-32177P and i

NEDE-32178P) 5.

3/1/95 036-95 GE GIRAFFE Audit Report j

6.

3/8/95 039-95 GE GIRAFFE Testing and TRACG Computer Code i

)

7.

4/13/95 046-95*

SBWR Test and Analysis Program Description NEDC-32391P, Rev.

B (Proprietary) 8.

4/17/95 052-95 GE PANDA Audit Report (Proprietary) 9.

4/14/95 057-95 Thermal-Hydraulic Data Report of PANTHERS-PCC Tests 10.

4/21/95 062-95 SBWR PANTHERS Audit Report (Proprietary) (Cover letter for enclosure: Audit Report #ARP 95-3 (Proprietary), O.A Audit of SBWR PANTHERS Test Program by Services and Projects Qual, dated 2/6 - 2/8/95 11.

4/25/95 063-95 PANTHERS-PCC Apparent Test Results 12.

6/30/95 086-95 SBWR Second copy of PANTHERS-PCC Data Tape 13.

7/6/95 098-95 SBWR Data Analysis Report of PANTHERS PCC Tests i

14.

7/14/95 105-95 SBWR GIRAFFE Heat Removal Performance Tests TP&Ps (including information and drawing package) Report TOGE110-T07 Revision May 31,1995 C: Nil 3. doc

SBWR PROPRIETARY SUBMITTALS TO THE NRC 1994 DATE MFN NO.

SUBJECT 1.

1/18/94 006-94 NRC Requests for Additional Information (RAls) on the Simplified Boiling Water Reactor (SBWR) Design 2.

4/21/94 026-94 NRC Requests for Additional Information (RAls) on the SBWR Design, RAI 950.43 3,

3/23/94 036-94 NRC Requests for Additional Information (RAI) on the Simplified Boiling Water Reactor (SBWR) Design 4,

4/29/94 062-94 NRC Requests for Additional Information (RAls) on the Simplified Boiling Water Reactor (SBWR) Design 5.

6/15/94 066-94 Transmittal of TRACG User's Manual 6.

5/31/94 077-94 NRC Requests for Additional Information on the Simplified Boiling Water Reactor (SBWR) Design (RAls 1-22) 7.

8/10/94 095-94 SBWR Test and Analysis Program Description, NEDC-32391-P (Draft) 8.

9/20/94 096-94 Submittal of Additional Information on Licensing Topical Reports (NEDE-32176P, NEDE-32177P and NEDE-32178P) 9.

8/18/94 100-94 Slides Used at SBWR NRC Meeting August 18,1994 to Discuss the SBWR Test and Analysis Program Description, NEDC-32391-P (Draft) 10.

9/15/94 109-94 SBWR Test and Analysis Program Description. NEDC-32391-P, Revision A 11.

9/27/94 114-94 Submittal of Pre-test Calculations for the PANDA Steady-state Tests (RAI 900.44) 12.

9/28/94 119-94 Submittal of Pre-test Calculations for the PANTHERS-PCC Tests (RAI 900.30) 13.

10/14/94 133-94 Submittal of Additional information on Licensing Topical Reports (NEDE-32176P, NEDE-32177P and NEDE-32178P) 14.

11/1/94 137-94 NRC Requests for AdditionalInformation on the Simplified Boiling Water Reactor (SBWR) Design (RAls 950.49. 950.50, 950.52 and 950.53) 15.

12/15/94 15S-94 NRC Requests for Additional Information (RAI 900.62)

C:\\jll3. doc

p p

i GENuclearEnergy.

MFN 138-95

.i bec:.. (E-Mail w/att. except as noted) i J. A. Beard R. II. Buchholz

- T. Cook (doe)

(2 paper copies w/att. plus E-Mail w/att.)

A. Ehlers R. T. Fernandez (EPRI)

J. Ilardy J. E. Leatherman J. E. Quinn T. J. Mulford (EPRI)

(2 paper copies w/att. plus E-Mail w/att.)

{

F. A. Ross (doe)

(1 paper copy w/att plus E-Mail w/att.)

K. T. Schaefer j'

B. Shiralkar R. Srinivasan (EPRI)

J. E. Torbeck GE Master File M/C 747 (1 paper copy w/att. plus E-Mail w/att.)

SBWR Project File (1 paper copy w/att. plus E-Mail w/att.)