ML20083D060

From kanterella
Jump to navigation Jump to search
Answers to Second Set of Interrogatories Re Qa/Qc
ML20083D060
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 12/19/1983
From:
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
AIR AND WATER POLLUTION PATROL
References
NUDOCS 8312270181
Download: ML20083D060 (20)


Text

-

DOCKETED USNRC UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION 55 DEC 23 A!0:' IDI In the Matter of

)

)

Philadelphia' Electric Company

)

Docket Nos. 50-352

)

50-353 (Limerick Generating Station

)

, Units 1 and 2)

)

APPLICANT'S ANSWERS TO INTERVENOR AWPP'S SECOND SET OF INTERROGATORIES ON QUALITY ASSURANCE / CONTROL I

DISCOVERY 16 December 19, 1983 l

I i

8312270181 831219 PDR ADOCK 05000352 O

PDR

' \\)

s.

3 Interroaatory No. 1 Indicate total number of welds involved directly or indirectly with safety-relatd piping, reactor vessel, reactor vessel components and all units into and out of the reactor vessel which require or required welding.

Answer Using various techniques, it has been estimated that there are over 195,000 safety-related welds joining safety-related piping, reactor vessels and reactor vessel internals for the Limerick Generating Station.

The preceeding estimate includes safety-related piping into and ot* of the reactor vessel.

Participants in Preparation of Answer Vincent S. Boyer, Senior Vice President - Nuclear Power Philadelphia Electric Company 2301 Market Street Philadelphia, PA 19101 J.J. Fedick Construction - Engineer Philadelphia Electric Company 2301 Market Street l

Philadelphia, PA 19101 I

2 l

l l

l

Interroontory No. 2 Indicate the types of each weld performed and the name and proof of qualification of the welder who performed such veld or welds.

Answer The types of field welds performed at Limerick Generating Station for safety-related piping, reactor vessels and reactor l

vessel internals are shown on the associated drawings, and specifications for the particular comoonent, system, or piping.

Additional welding details are found in the field welding procedures, a list of which is attached.

Each welder is qualified to perform welding to the appropriate welding procedures that he is using.

The following description is provided as an example of the controls applied at Limerick to assure that a welder is qualified to the procedure to which he is working:

When a field piping veld is to be perfelied, it is verified that the welder assigned is qualified prior to issuance of weld filler material.

During the performance of the weld, the quality control inspector verifies, during surveillance inspections for selected pipe welds, that authorization has been granted for the weld filler material in the welder's possession, and that the welder is qualified to perform the weld.

To retrieve the inspection records and associated information for field pipe welds, the weld must be selected and identified by 3

' pipe lino number, drawing number and field weld number.

Onco the weld is selected, the specific type of wold can 'tje identified, the welding procedure which was used and the welder (s) identification by review of the inspection recor:t und associated documents.

Witn the welder's identification, his qualifications to the welding procedure can be retrieved.

The above information and proof of welder's qualifications are stored on site either in hard copy or in microfilm.

While there are variations in the methods unod by vendars and subcontractors, controls equivalent to those described f or field pipe welds are applied as required by their QA programs and implementing documents.

Participants in Preparation of Answer Vincent S.

Boyer, Senior Vice President - Nucleal Power Philadelphia Electric Company 2301 Market Street Philadelphia, PA 19101 J.

M.

Corcoran Quality Assu r,ance Field Branch Head

~

Philadelphia Electric Company 2301 Market Street Philadelphia, PA 19101 D. T. Clohecy Quality Assurance - Engineer Philadelphia Electric Company 2301 Market Street Philadelphia, PA 19101 4

s

. INTERROGATORY 2 ATTACilMl!NT 1 Field Welding Procedures for Pip'e Pit 0CEDURE

.DESCitIPTION APPLICATION GiS-FM GENERAL WELDING FERRITE AND STANDARD.

IIARTENSITIC GIS-SN GENERAL 11ELDING STAINLESS AND STANDARD NICl:EL G1S-DH GENERAL WELDING DISSIllILAR HETALS STANDARD GWS-TC GENERAL WELDING TliERM0 COUPLE ATTACil.

STANDARD GSS-NF GENERAL SOLDERING NONFERROUS STANDARD 1

GBS-NF

  • NONFERROUS STANDARD i

,j 4

ESR-1 ELIMINATION OF ASHE SECTION III l

SURFACE DEFECTS CODE G1S-NF GENERAL WELDING NON-FERROUS STANDARD GPS-1 GENERAL PURGING INTERNAL GAS

.I.

SPECIFICATION PURGING

-i l

I 2/1 Page 1 of 7 i

n INTERROGATORY 2 Nt*1*ACllHENT 1 Field Walding Procsdures for Pipe PROCEDURE DESCRIPTION APPLICATION IRP-1 REPAIR PROCEDURE INSPECTION AND REPAIR OF SURFACE DEFECTS Pl-A-Lh WELDING NON-CRITICAL PROCEDURE CARDON STEEL SPECIFICATION WELDS BY SHAW WELDING METHOD Pl-A-c-Lh WELDING NON-CRITICAL PROCEDURE CARBON STEEL SPECIFICATION WELDS BY SM'AW WELDING METHOD Pl-AT-Lh WELDING CARBONSTEELW5LDS PROCEDURE BY GTAW 6 SHAN SPECIFICATION WELDING METHODS Pl-At-Lh WELDING CARBON STEEL BUTT

.(CVN),

, PROCEDURE WELDS IN NUCLEAR SPECIFICATION IMPACT-TESTED SYSTEMS BY GTAN 6 SHAW WELDING HETHOD Pl-T WELDING

' CARBON STEEL WELDS PROCEDURE BY GTAW WELDING SPECIFICATION HETHOD PI-T (CVN)

P1-AT-Lh-1 R00T,2ND, AND SOCKET WELDS COVER PASSES:

(LIOUID PENETRANT GTAW EXAMINED)

BALANCE: SMAW P1-F WELDING

' FLUX CORED ARC WEL' DING

~

. PROCEDURE USING'SELF-SilIELDING ELEC-SPECIFICATION TRODES OF CARBON STEEL PIPE OR PLATE.

..'I Pl-F (CO )

WELDING FLUX. CORED ARC WELDING OF 2

PROCEDUaE CARBON STEEL USING LOCKING SPECIFICATION

' STRIPS AND EXTERNAL GAS I

SilIELDING, 2/I Page 2 of 7

____J

1 TNTl!RROGATORY 2 K!TACilN!!NT 1 I

FinId Welding Prnesdures for Pips PROCEDURE DESCRIPTION APPLICATION P1-F WELDING FLUX. CORED ARC WELDING OF (A-C0 )

PROCEDURE CARBON STEEL USING AN.EX-2 SPECIFICATION TERNAL SilIELDING GAS P4-A WELDING CHROME-HOLY WELDS PROCEDURE BY SHAW WELDING l

SPECIFICATION HETHOD P4-AT WELDING CHROME-MOLY WELDS PROCEDURE BY GTAN 4.SP, LAW SPECIFICATION WELDI!Fi ?!ET!!OD P4-T WELDING CHROME-HOLY WELDS PROCEDURE BY GTAN WELDING SPECIFICATION METi!0D l

P4, WELDING Cl! ROME-MOLY TO l

P1-AT PROCEDURE CARBON STEEL WELDS SPECIFICATION BY GTAW 6 SMAN WELDING METHODS P4, WELDING

' CHROME-HOLY TO PI-T-1 PROCEDURE CARBON STEEL WELDS SPECIFICATION BY GTAW WELDING METHOD l'

P4, WELDING CHROME-HOLY TO 1

PI-AT (A3)

PROCEDURE CARBON STEEL WELDS SPECIFICATION BY GTAW AND SHAW l

P1-A- Lh WELDING PROCEDURE CARBON STEEL (CVN)

SPECIFICATION WELDS BY SHAW PS-A WELDING CHROME-MOLY WELDS PROCEDURE BY SHAW SPECIFICATION WELDING HETHOD 2/1

~

Page 3 of 7

.. V 1

INTL!RROGAT0ltY.!

Naahuitsusa a

~

F; eld Walding Prscedures for Pip.s APPLICATION Pi10CEDURE

, DESCRIPTION P5-AT-Ag WELDING CilROME-HOLY WELDS PROCEDURE BY GTAW 6 S)Wi

~

SPECIFICATION WELDING METHODS

-l P5-T WELDING CllR0t!E-HOLY WELDS PROCEDURE BY GTAW WELDING SPECIFICATION HETl!OD P5-T-Ag WELDING CHROME-MOLY WELDS l

PROCEDURE BY GTAW WELDING SPECIFICATION METHOD 4

l P5,Pl-A WELDING CilROME-HOLI TO

PS, WELDING CHROME-HOLY TO I

F1-AT-Ag PROCEDURE CARBON STEEL WELDS SPECIFICATION BY GTAW 6 SMAN l

WELDING MET 110DS l

Ci! ROME-MOLY TO P5,P1-AT WELDING PROCEDURE CARBON STEEL USING SPECIFICATION GTAW 4 SMAW I

PS, WELDING CHROME-HOLY TO I

Pl '.'-l PROCEDURE CARBON STEEL WELDS SPECIFICATION BY GTAW WELDING METHOD l

PS,P4-A WELDING CHROME-MOLY WELDS PROCEDURE BY SHAW WELDING SPECIFICATION HETHOD r

P5,

. WELDING CHROME-HOLY WELDS f

l P4-AT-Ag PROCEDURE BY SHAW WLLDING SPECIFICATION HETHOD G

2/1 Page 4 of 7 f

i

_ _ ~ _..

^

l MITUlul0GATORY ' 2 AT'l'ACilolliNT 1 7

Field Walding Procsdurss for Pipe-PROCEDUkE DESCRIPTION APPLICATION PS,P4-T WELDING CHROME-MOLY WELbS PROCEDURE BY GTAW WELDING SPECIFICATION METil0D P8-A WELDING STAINLESS STEEL l

PROCEDURE WELDS BY S!!AN SPECIFICATION WELDING HETliOD P8-AT-Ag WELDING STAINLESS STEEL PROCEDURE WELDS BY GTAN 6 SPECIFICATION SMAN WELDING HETliOD f

P8, WELDING HEATSINK WELDING S.S.

AT-Ag PROCEDURE BY GTAN 6 SMAN (ilSW)

SPECIFICATION P8, WELDING llEATSINK WELDING S.S.

AT-Ag-1 PROCEDURE

~

BY GTAW 6 SMAN (llSli)*

SPECIFICATION

~

~

PS-T-Ag WELDING

' STAINLESS STEEL PROCEDURE

' WELDS BY GTAN I

SPECIFICATION WELDING HET110D l

P8-AT-Ag-WELDING STAINLESS STEEL 1

PROCEDURE WELDS BY GTAW 6 SPECIFICATION SMAN WELDING METHOD ~

i I

l P8 (Gl),

WELDING STAINLESS STEEL TO P1 (Gl)-

PROCEDURE CARBON STEEL WELDS AT-Ag

. SPECIFICATION BY GTAW G SMAN (CVN).

2'-

P8,PI-AT-WELDING STAINLESS STEEL TO Ag (CVN)

PROCEDURE CARBON STEEL WELDS (BtJrTERED)

SPECIFICATION BY GTAN 4 SMAW 2/1 Page S of 7

. ~..

a.

Field Walding Proccduros for Pipo PROCEDURE

. DESCRIPTION

. APPLICATION P8,PS-AT-WELDING STAINLESS STEEL' Ag (A8)

PROCEDURE TO CHR0!!E->10LY SPECIFICATION WELDS BY GTAW Q SifAW P8,PS-A WELDING STAINLESS STEEL TO PROCEDURE CHROME-HOLY WELDS SPECIFICATION BY S) TAW P8,P1-A WELDING STAINLESS STEEL TO PROCEDURE CARBON STEEL WELDS SPECIFICATION BY SHAN WELDING HET!!0DS P8,P1-AT-WELDING STAINLESS STEEL TO l

Ag PROCEDURE CARBON STEEL WELDS SPECIFICATION BY GTAW 6 S!!AN WELDING METil0DS

\\

P8,P1-T-WELDING STAINLESS STEEL TO Ag PROCEDURE CARBON STEEL WELDS SPECIFICATION BY GTAW WELDING l

HETHOD l

PS,P4-AT-WELDING

STAINLESS STEEL l

Ag

. PROCEDURE

'TO CHROME-MOLY SPECIFICATION WELDS BY GTAN 4 SMAW WELDING METHODS l

P8,P4-T-WELDING STAINLESS STEEL TO Ag PROCEDURE CHROME-MOLY WELDS SPECIFICATION BY GTAW WELDING MET 110D P8,P5-T-WELDING STAINLESS STEEL TO Ag (F-43)

PROCEDURE CHROME-MOLY WELDS SPECIFICATION BY GTAW WELDING METHOD P8,P1-AT-ROOT, 2ND 4 COVER CS TO SS FOR Ag-1 PASSES GTAW ON SOCKET WELDS 4

S.W. BALANCE SMAW 2/1 Page 6 of 7

. _. ~ _.

INTt!RnouNruta e a n au sruan 4 Field Walding Procedures for Pipe.

PROCEDURE DESCRIPTION APPLICNPION l

l P8,PS-AT-GTAW AND SHAlf GIROME-MOLEY TO' Ag AUSTENITIC SS P8,PI-AT-WELDING STAINLESS STEEL Ag (CVN)

PROCEDURE TO IMPACT TEST SPECIFICATION CARBON STEEL USING GTAlf 6 SHAlf l

(

P-107, ifELDING BRAZING COPPER I

11-101-1 PROCEDURE SOCKET JOINTS SPECIFICATION BY HANUAL TORCFi METHOD P-107, WELDING SOLDERING COPPER

!!-101-S1 PROCEDURE SOCKET JOINTS SPECIFICATION BY MANUAL TORCH METl!0D P-107, ifELDING BRAZING COPPER

!!-101,,2 PROCEDURE SOCKET JOINTS BY SPECIFICATION MANUAL TORCH METHOD P-107, WELDING

,B. RAZING COPPER 11-101-4 PROCEDURE JOINTS BY MANUAL SPECIFICATION TORCl! METHOD t

P45-T-AG GTAN ifELDING OF P45 (65)

MAT' LS AND CARPENTER j,

20Cb-3 P45-A-SMAW WELDING OF P45 j

(135)

MAT'LS AND CARPENTER 20 Cb-3 I

1 l

e-t 2/L Page 7 of 7 e

. ~. -

INTERROGATORY 2 rl*A*Al tiMEN*1' 2 Field -Walding Prscedurss for Geanr'al' EIsetri*o (NED) Piping I

PROCEDURE

- DESCRIPTION APPLICATION l

GWS-FM GENERAL WELDING FERRITE AND STANDARD HARTENSITIC

~

GWS-SN GENERAL WELDING STAINLESS AND ST.*3DARD NICKEL

\\

l\\

t GWS-DM GENERAL WELDING DISSIMILAR METALS STANDARD GWS-TC GENERAL WELDING.

'THER0 COUPLE ATTACH.

STANDARD i

GPS-I GENERAL PURGING INTERNAL GAS' SPECIFICATION

. PURGING

'\\

ESR-1 ELIMINATION OF

' NUCLEAR AND SURFACE DEFECTS RdN -NUCLEAR

.i IRP INSPECTION AND REPAIR OF NUCLEAR AND i

SURFACE DEFECTS NON-NUCLEAR l-Pl-A-Lh WEL6ING CARBON STEEL (CVN)

PROCEDURE WELDS BY SMAW -

SPECIFICATION PI-AT-Lh-

  • WELDING SOCKET WELDS --

'. 3 :

1 PROCEDURE LIQUID PENETRA!E

'~

SPECIFICATION EXAMINED 2/2

... Page 1 -o f - -

i INTERROGATORY 2 hll'AOlhENT2

~

o Field Welliing Procedures for General' Electric (NED) Piping PROCEDURE

.DF.SCRIPTION

. APPLICATION PI-AT-Lh WELDIN'G CARBON STEEL WELDS PROCEDURE BY GTAW 6 SHAW SPECIFICATION WELDING METHODS WELDING CARBON STEEL DUTT PI-AT-Lh PROCEDURE WELDS IN NUCLEAR (CVN)

SPECIFICATION

' IMPACT-TESTED SYSTEMS BY GTAW 4 SHAW WELDING METil0D I

PI-T WELDING CARBON STEEL WELDS PROCEDURE BY GTAW WELDING.-

SPECIFICATION METHOD PI-T W'ELDING'

'CARBONSTEELifhLDSBY (CVN)

PROCEDURE' GTAW WELDING HETHOD '

SPECIFICATION IHPACT TESTED.HATERIALS P8-AT-Ag-WELDING STAINLESS STEEL t

1

. PROCEDURE.

WELDS BY GTAW.AND SPECIFICATION SMAN WELDING METii0D P8-T-Ag WELDING

' STAINLESS STEEL PROCEDURE lisLDS BY GTAW SPECIFICATION WEL' DING METHOD s.

P8-AT-Ag WELDING STAINLESS STEEL PROCEDURE WELDS:BY GTAW 4 SPECIFICATION SHAN WELDING MET!!OD

~

l

'P43,P8-

. WELDING STAINLESS STEEL TO AT-Ag

' PROCEDURE INCONEL BY GTAW 4 SHAW

' SPECIFICATION P8,P'l-T-WELDING STAINLESS STEEL TO Ag PROCEDURE CARBON STEEL WELDS SPECIFICATION BY GTAW WELDING METHOD 2/2 Page 2 of 2

... ~.

0

____..-____,.___.-.,-..__.m

,., ~,. _. _..,. _,, -.

e

' gs.

INTERROGATORY.2 Attachnient 3 i

Welding Procedures for'the Reactor Vesse'l', its C'ompone. ts and Appurtances.

n s

Procedure _

Description Application SRSE l-7 General welding Procedu're for' SMAW'&

Reactor. Vessel. Safe-end and' pipe to Reactor. vessel GTAW

' Welds.

ater'ial-Manu'al GT W/Sh.:W '.-

c":'l '

.'LRI-79-1-2D IInconel Filler

~~

n.. ::. t.

..n

~

. ;.. ;:9. \\

. Carbon Steel to Carbon Steel-Manual.'

LRI-79-1-4D GTAW/SMAW LRI-79-1.5 0 Carbon Steel Overlay (P-1)-Manual SMA,W

.LRI-79-1-6W/D Inconel Butter / Groove Weld of Stainless

- l Steel Couplings 1

Inconel to Inconel-Automatic GTAW

. LRI'-7.9 s ';7 D...

n.:..,,3..

s :+ T '..

C. _

x s

f. LRI-79-1-7D.p,,',;. }nconel to Inconel-Automatic' GTAW

.' c ' n '

'..,Alte,rnate.'. :-

.,,, _....{

H,.

. " + _

u.-

.s..

i. e..,-

LRI-79-1-90 Inconel' (0 pen Root)F-43-Manual GTAW LRI-79-1.10D Carbon Steel to Carbon Steel (0 pen Root)

GTAW LRI-79-1-150 Carbon Steel to Carbon,, Steel-Automatic GTAW DU,GWP-1 Genshal Weld Procedur'e RPV Internals i

LHI-WPS-8.43-1

  • Stainless Steel to INonel GTAW/SHAW

~

(Hanual) l UtI-WPS-43.43-1, Inconel to Inconel GTAW/SMAN (Manual)

LMI-WPS-8.8-1 Stainless Steel to Stainless Steel, Ma.nual GTAW LMI-WPS-8.8-2 Stainless Steel to Stainless Steel, Haqual GTAW 4

U!I-WPS-8.8-3 Stainless Steel to Stainless Steel, Manual GTAW**

~~ ~

LMI-WPS-1.1-1 Carbon Steel to Carbon Steel, Manual SHAW 4.-

'LMI-WPS-1.1-2 Carbon Steel to Carbon Steel, Manual SHAN Note:

Applications are defined by drawings and specifications

.m

"?,.

INTli(tROGITORY 2* Attac$ ment'3

' Welding Pro'cedures for the Reactor Vessel,'its Components and Appurtances.

Procedure Description Application IMI-WPS-1. 8-1 Buttering of Carbon Steel, Manual SHAW RPV Internals

'IMI-WPS-1.43-1 Carbon Steel. Buttered.with Indonel,

' '. c -

Manual SMAlf,

^ 'r

~. -

. ~.

r-

__c,

~.

LMI-WPS,43.43-2

'Inconel to Inconel,'Hanual GTAW/SMAN LMI-WPS-8. 8-4 Stainless Steel to Stainless Steel,,

Mandal GTAW Stainless Ste'l to'Inconel,' Automatic DlI-WPS-8.4 3-2 e

LMI-NPS-8.'8-S S'ainless Steel to Sta'inless Steel, t

Automatic

+.-

LMI-WPS'-43.4 3-3 ',

Inconel'to In'cenel, H$nual GTAW WP-1 Weld Procedure For Mild Steel to Hild RPV Internals Installation-Steel ifP-6 Weld Repair Procedure GWS-1 General Welding Specifications W-1/1-OS-1L

' Carbon Steel to Carbon Steel, Manual'SMAN 1

~.

W-1/1,-CTS-1L Carbon St. eel to Carbon Steel, Manual GTAN/SMAN

?

W-1/1-0TS-1L Carbon Steel to Carbon Steel, Manual GTAW/SHAli W-8/8-CTS-1L Stainless Steel to Stainless Steel, Hanual GTAN/SMAW W-8/8-OS-1L Stainless Steel to Sta'inless Steel,' Manual GTAlf/SMAN W-8/8-0TS-1L StainlessSteeltoStainlessSteel,Aanual GTAN/SMAW 3

W-43/43-CTS-1L Inconel to Inconel, Manual GTAW/SMAW

]

Note:

Applications are defined by drawings and specifications

1

's.-

e e'*,

INTERROGATORY 2 'Atttchm:nt J.

ifolding' Pro'cedures for the Reactor Vessel, its Components and Appurt inces.

Proc. dure Description Application e

.lf-43/43-0TS-1L Inconcel to Inconel, Manual GTA/SMAlf RPV Internals Installation

~

~

W-8/2-CTS-IL

. Stainless Steel to Carbon ' Steel,.

  • Manual GTAlf/SMAlf

.s

~.. -:

.;>y, -

,.,, p. :.[.

'W-8/1-MS-1L-Stainless Steel to Carbon Steel, i

" ' ~ -

Manual GTAW/SHAlf j

l W-43/8-0TS-1L' InconeltoStainlessSteel,ManualGT'AIO

~

l SMAW

[

l l

. DBif-1 Draw Bead Welding l

PRS-1/1 Jet' Pump Ada} te'r to Shioud Suppor't i

-' Welding Sequence Procedure

.1

.o s.4;, 7 1

N-8/8-CTA-1L

, Stainless Steel to Stainless Steel,-

l Automatic GTAlf l

\\

l i

1

~,

t

(

I

.1)

. :t '

,'t'

  • 1 l

1 1

j l

Note:

Applications are defined by drawings and specifications

-~

i j

i

- -. ~.

INTERROGATORY 2 * ' ' Attachment 3 Weld Procedure Spec'1fication for RPV.

Number

  • 'Nurner WPS-101-1F43
  • WPS'-239,-IF43 7

WPS-103-1F5 WPS-239-2F43 WPS-103-2F43 WPS-301-IF4 WPS-103-3F5 WPS-301-2F4 WPS-103-4F4 WPS-301-3F4 WPS-123-1F7 WPS-301-5F4

  • WPS-123-2F43 WPS-303-1F4 WPS-123-3F5F7 WPS-303-2F4

'WPS-143-1F5F7 WPS-305-1F5 WPS-143,-3F43 WPS-309-2F43 WPS-143-4F5F7 WPS-323-IF6 WPS-143-8F7 WPS-323-2F4F6 t

l WPS-201-2F4 WPS-339-1F43

.i!

WPS-203-1F4 WP,S-339-2F43 WPS-203-2F4 WPS-339-5F43

  • WPS-205-1F5 WPS-339-6F43 WPS-205-2F5 WPS-343-1F4F6 WPS-205-3F5 WPS-343-2F6 WPS-209-1F43 WPS-403-2F4 WPS-231-1F6 WPS-433-1F6F4
[

WPS-201-1F4 WPS-331-2F6F4 WPS-433-3F6 WPS-435-4F7 WPS-433-4F6F4 NPS-439-1F43

.T.

u.. -

Wald Procedure Specification for RPV (Continbed)

. Number N'PS-439-2F43 WPS-439-3F43 WPS-439-8F43 WPS-439-9'F43'

'WPS-439-15F43 WPS-800

^

t' WPS-830 WPS-840 WPS-82'O 4D 9

i

...I

,ff

.y >]

1 3,.3 a.

4 d

O t

t i

r-

,\\

b

.f

,j 4

N' n.7

' EI.

Interroactory No. 3 Provide all radiographs of all welds in Interrogatory 1 above, or other physical tests or evidence re weld quality.

Answer There are approximately 40,000 radiograph film sheets for field welds and approximately 50,000 radiograph film sheets for vendor velds.

The radiographs and records of other nondestructive examinations are stored on site or at other records storage locations.

Applicant will make specifically identified radiographs available to AWPP's technical representative upon reasonable notice after receiving information indicating that the AWPP representative is qualified to evaluate the radiographs, e.g. SNT-TC-1A, Level II or III certification in radiography.

Participants in Preparation of Answer Vincent S.

Boyer, Senior Vice President - Nuclear Power Philadelphia Electric Company 2301 Market Street Philadelphia, PA 19101 J. M. Corcoran Quality Assurance Field Branch Head Philadelphia El'ectric Company 2301 Market Street Philadelphia, PA 19101 D. T. Clohecy Quality Assurance - Engineer Philadelphia Electric Company 2301 Market Street Philadelphia, PA 19101 C

5

Interrogatorv No. 4 Provide copies of all IE reports in which a safety-related welding infraction is discussed or described.

Answer Copies of IE reports in which a safety-related welding infraction is discussed or described have been previously provided and is available for inspection and copying under Discovery 14, Item 1; Discovery 2 enclosure 2 Items 1, 2, 3; and Discovery 15, Item 1.

Participants in Preparation of Answer Vincent S. Boyer, Senior Vice President - Nuclear Power Philadelphia Electric Company 2301 Market Street Philadelphia, PA 19101 D. T. Clohecy Quality Assurance - Engineer Philadelphia Electric Company 23S1 Market Street Philadelphia, PA 19101 l

l l

I i

9 C

6

COWiONWEALTH OF PENNSYLVANIA ss.

COUNTY OF PHILADELPHIA V. S.

Boyer, being first sworn, deposes and states:

That he is Senior Vice President of Philadelphia Electric Company, the Applicant herein; that he has read the' -

foregoing Applicant's Answers to Intervenor AWPP.'.s Second Set of Interrogatories on Quality Assurance / Control and knows the contents thereof; and that the statetuents and matters set forth therein are true and correct to the best of his knowledge, information and belief.

?

Senior Vice PrVsident Subscribed and sworn to h

j before me this /k day of December, 1983.

Notary Public Pt.TR) CIA U. GCHOLU Notary PulAr., ItileM;:nia, huladelphia Co.

My Com.Tealcis Lapares february 10,198G ta