ML20081C859

From kanterella
Jump to navigation Jump to search
Submits Supplemental Response to IE Bulletin 80-16, Potential Misapplication of Rosemount,Inc Models 1151 & 1152 Pressure Transmitters W/Either a or D Output Codes. Transmitters Will Be Replaced
ML20081C859
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 10/11/1983
From: Bayne J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
REF-SSINS-6820 IEB-80-16, JPN-83-87, NUDOCS 8310310364
Download: ML20081C859 (2)


Text

.

123 Main Street r

e.*

Whrte Plains, Ne* Wrk 10601 914 681.0240

  1. > NewYo.rkPbwer

= " " " " -

Executive Vice President 4# Authonty

~ ~~ e -

October 11, 1983 JPN-83-87 Dr. Thomas E. Murley Regional Administrator Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, Pennsylvania 19406

Subject:

James A. FitzPatrick Nuclear Power Plant Docket No. 50-333 IE Bulletin No. 80-16 Potential Misapplication of Rosemount Inc.

Models 1151 and 1152 Pressure Transmitters with Either "A" or "D" Output Codes

References:

1.

NUREG/CR-3047 - Closecut of IE Bulletin 80-16:

Potential Misapplication of Rosemount Pressure Transmitters, dated July 12, 1983.

2.

PASNY letter, R.

J.

Pasternak to B.

H. Grier, dated July 22, 1980 (JAFP-80-591).

Dear Sir:

As discussed in Reference 1, the Authority's original re-sponse (Reference 2) to NRC Bulletin 80-16 stated that seventy-six (76) pressure transmitters stored in the ware-house for the Analog Trip Transmitter System required cor-rective action prior to use in safety systems.

The Authority has since informed Mr.

L.

Doerflein of the Resident Inspector's Office that it is now the Authority's intention to dispose of these transmitters and buy fully qualified replacement transmitters, because they do not meet environmental qualification requirements for new safety-related equipment.

Quality control hold tags will be in-stalled on all of these transmitters in storage pending final disposition.

8310310364 831011 PDR ADOCK 05000333 G

PDR

r The Authority considers that this closes IE Bulletin 80-16 for the FitzPatrick Plant.

If you have any questions, please contact J. A.

Gray, Jr.

of ray staf f.

Very truly yours, QQ

-I J./P.) o1)_

Bayne

'J xecutive Vice President Nuclear Generation cc:

Office of the Resident Inspector U.S.

Nuclear Regulatory Commission P.O.

Box 136 Lycoraing,

N.Y.

13093