Pp A
~
q: ~e
~
II EGrG
..s.. ~
P.O. BOX 1625, IDAHO FALLS, IDAHO 83415 April 5,1983 Mr. J. E. Solecki, Chief Water Reactor Research Branch Reactor Operations and Programs Division Idaho Operations Office - DOE Idaho Falls, ID S3401 TRANSMITTAL OF REPORT FOR SEVERE ACCIDENT SEQUENCE ANALYSIS PROGRAM (A5354) -
TRC-26-83 Ref:
(a) Ariyses of sta== Generatc: ::de Rup:ures in Ark >:sas Nuclear Gr.e Ur.d: S, EGG-NTAP-6226, April 1983.
Dear Mr. Solecki:
The referenced report is attached for your information and review.
The work documented in the attached report was performed as part of the Severe Accident Analysis Program at the request of the Nuclear Regulatory Commission.
Analyses of hypothetical steam generator tube ruptures in Arkansas Huclear One Unit 2 (AN02), a Combustion Engineering pressurized water reactor, were performed using the RELAP5 computer code.
The analyses indicated that the reactor operators could successfully mitigate the effects of steam generator tune ruptures in AN02.
The attached report completes Node 21-02 of FIN No. A6354.
Very truly yours, s
T. ~ R. Charlton, Manager Code Assessment and Verification Branch CBD:sb
Attachment:
As Stated cc:
B. Agrawal, RES R. Curtis, RES T. Marsh, NRR /
R. W. Kiehn, EGSG Idaho (w/o Attacn.)
M 3 8310310081 830720 PDR FOIA m
BELL-83-163 PDR JCf