ML20078S357

From kanterella
Jump to navigation Jump to search
Unit 2 Refueling 20 Inservice Insp Summary Rept for Form NIS-1
ML20078S357
Person / Time
Site: Point Beach NextEra Energy icon.png
Issue date: 02/17/1995
From:
WISCONSIN ELECTRIC POWER CO.
To:
Shared Package
ML20078S354 List:
References
PROC-950217, NUDOCS 9502240102
Download: ML20078S357 (65)


Text

  • ~ " '

Wisconsin Electric Power Co 231 West Michigan Avenue Milwaukee WI 53201 Point Beach Nuclear Plaut, Unit 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Commercial Service Date 10/01/72 UNIT 2 REFUELING 20 INSERVICE INSPECTION

SUMMARY

REPORT FOR FORM NIS-1 Z!0!ff l_A4w t e ate:

Written by:

e Reviewed by:

M

>~ I -6 ate:

Approved by:

Date: cf-/N I 9502240102 950217 PDR ADOCK 05000301 0

pon

e Wisconsin Electric Power Co.

231 West Michigan Avenue Milwaukee, WI 53201 Point Beach Nuclear Plant. Unit 2 6610 Nuclear Road Two Rivers, WI $4241 Docket 50-301 Commercial service Date 10/01n2 Acronvms ASME American Society of Mechanical Engineers EBASCO EBASCO Services Incorporated EWR Engineering Work Request IDR Indication Disposition Report IN Information Notice ISI Inservice Inspection LTP Long Term Plan MT Magnetic Particle Examination MWR Maintenance Work Request NDE Nondestructive Examination NES Nuclear Engineering Section NRC Nuclear Regulatory Commission P13NP Point Beach Nuclear Plant l

l P-G Phillips Getschow PT Dye Penetrant Examination PWA Professional Welding Associates QTS Quality Technical Services RT Radiographic Examination RRM Repair / Replacement / Modification Page 2 of 21

+

Wisconsin Electric Power Co.

231 West Michigan Avenue Mdwaukee, W1 53201 Point Beach Nuclear Plant, Unit 2 1

6610 Nuclear Road Two Rivers, %1 54241 Docket 50-301 Commercial Service Date 10/01/72 UT Ultrasonic Examination l

VT Visual Examination WE Wisconsin Electric Power Company t

i' Page 3 of 21

n, t

Wisconsin Electric Power Co.

231 West Michigan Avenue l

Milwaukee.WI 53201 I

Point Beach Nuclear Plant. Unit 2 6610 Nuclear Road Two Rivers. WI 54241 i

Docket 50-301 Conunercial Service Date 10/0102 Table of Contents

1.0 INTRODUCTION

2.0 CODE CASFS 3.0 ABSTRACT OF EXAMINATIONS 3.1 Determination of Scope 3.2 Component / Weld Examinations 3.3 Completed Component / Weld Examinations 3.4 Pressure Tests 3.5 Snubber Surveillance Test 4.0 ABSTRACT OF CONDITIONS NOTED AND CORRECTIVE MEASURES TAKEN 4.1 Component / Weld 4.2 Pressure Te.its Page 4 of 21 r-

e Wisconsin Electric Power Co.

231 West Michigan Avenue Milwaukee.WI $3201 Point Bea:h Nuclear Plant. Unit 2 6610 Nuclear Road Two Rivers. WI $4241 Docket 50-301 Conunercial service Date 10/01/72 UNIT 2 REFUELING 20 INSERVICE INSPECTION

SUMMARY

1.0 INTRODUCTION

i From November 16,1993 to December 1,1994, non-destructive examinations of selected components at PBNP Unit 2 were performed. These examinations constitute the second examination of the Drst period, of the third 10-year interval at PBNP Unit 2. The time interval for this examination period included the Unit 2 Refueling 20 outage (U2R20) that ran from September i

24, 1994 to November 1,1994.

2.0 CODE CASES AND INTERPRETATIONS This report and examinations were completed applying the following:

2.1 ASME Code Interpretation, Section V111-1-83-17, which allows for computer generated data report forms to be used as long as size, arrangement, and content are identical.

2.2 Code Case N-460 2.3 Code Case N-448 3.0 ABSTRACT OF EXAMINATIONS 3.1 Determination of Scor>e Components and system areas were selected for examination in accordance with the following:

3.1.1 PBNP FSAR, Technical Specification Section 15.4.2.B 3.1.2 Long Term Inservice Examination Plan for Class 1, Class 2, and Class 3 systems at Point Beach Nuclear Plant, Third Interval, Unit 2.

3.1.3 NRC IE Bulletin 82-02 3.1.4 Requests of PBNP Personnel i

Page 5 of 21 1

+ - - -

-e

, -, =

r.,

-~~

w

6 a

Wisconsin Electric Power Co.

231 West Michigan Avenue Milwaukee, WI 53201 Point Beach Nuclear Plant. Unit 2 6610 Nuclear Road

{

Two Rivers. WI $4241 Docket 50-301 Cornmercial service Date 10/01/72 3.2 Scone of Component Weld Examinations Representative samples of the following components and system areas were examined with NDE techniques by WE (QTS), EBASCO, Phillips Getschow (P-G) and Professional Welding Associates (PWA) personnel.

Reactor Pressure Vessel Pressurizer B Steam Generator Class 1 Pressure Retaining Valve Bolting Class 1 Piping and Supports Class 2 Piping and Supports Class 3 Pipe Supports 3.3 Completed Component / Weld Examinations CODE or HEADING DESCRIPTION Exam Type Defines the requirement or reason for the examination performed.

86E-03 Examination performed as required by ASME Section XI,1986 Edition, No Addenda B01-03 Augmented examinations performed on Heavy Imad Liftmg Devices, per ANSI N14.6 B03-03 Augmented examinations performed on the Main Steam Bypass Line Energy Absorbers, per NRC letter dated April 10,1987 B04-03 Augmented examinations performed on Threaded Fasteners, per IEB 82-02 i

B05-03 Augmented examinations performed on Steam Generator Feedwater Nozzles, per Condition Report CR 92-004 D01-03 Augmented examinations performed on Reactor Vessel Head Cladding, per NRC IN 90-29 Page 6 of 21 1

Wisconsin Electric Pow:r Co.

231 West Michigan Avenue Milwaukee, WI 53201 Point Beach Nuclear Plant, Unit 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Commercial service Date 10/01/72 P12-03 Preservice examination, per RRM 94-0047 P13-03 Preservice examination, per RRM 94-0048 P14-03 Preservice examination, per RRM 94-0060 P15-03 Preservice examination, per RRM 94-0071 P16-03 Preservice examination, per RRM 94-0072 P17-03 Preservice examination, per RRM 94-0077 P18-03 Preservice examination, per RRM 94-0027 P19-03 Preservice examination, per RRM 94-0043 P20-03 Preservice examination, per RRM 94-0045 R02-03 Preservice examination, per IDR 93U2-7P012 R03-03 Preservice examination, per IDR 94U2-7P007 R04-03 Preservice examination, per IDR 94U2-7P010 R05-03 Preservice examination, per IDR 94U2-7P011 R06-03 Preservice examination, per IDR 94U2-7P012 R07-03 Preservice examination, per IDR 94U2-7P020 S02-03 Successive examination, per IWF-2420(b), reference IDR 93U2-7P002 XO8-03 Supplemental examination, per Data Sheet 94U2-160P10 X09-03 Supplemental examination, per Condition Report CR 94-472 X10-03 Supplemental examination, per Condition Report CR 94-473 X11-03 Supplemental examination, per Data Sheet 94U2-350P011 Ind Type A description of indications (i.e., N = no indications, R = recordable indications, I = insignificant or non-relevant indications, G = geometry).

Results Indicates the outcome of a particular exam.

P = Pass F = Fail C = Conditionally Accepted N = No examination performed Program Indicates whether or not ASME Section XI credit has been taken for the Credit exam. Augmented or other examinations not performed for an ASME Section XI requirement will be indicated by an N.

Following are database printouts that summarize the ISI examinations that were performed during the Unit 2 Refueling 20 outage.

Page 7 of 21

0 Wisconsin Electric Power Co.

231 West Michigan Avenue MDwaukee, WI 53201 Point Beach Nuclear Plant, Urut 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Comrnercial Service Date 10/01/72 Examinations (See Pages 8-1 through 8-38) i i

Page 8 of 21

i Wisconsin Electric Power Cornpany Point Beach Nuclear Plant, Unit 2 231 Wr.st hiichigan Avenue 6610 Nuclear Road ht@;aukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/0ln2 COhiPONENT IDENTIFICATION h1ETilOD EXAh!

EXAh!

EXAh! DATA RESULTS PROGRAh! IND COh!PONENT DESCRIPTION TYPE DATE SIlEET CREDIT TYP ITEh!

ISOh1ETRIC DIA.

TillCKNESS 4

' RELIEF h1ATERIAL A & B

= = = = = = = = = __ _ = = = = = = = _ = = = = = = = = = =._ = = __ = = = = = = = = = = _.= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =

01-PSS VT-3 86E-03 10/15/94 94U2-754P060 P

Y N

RIGID SUPPORT N/A ISI-PRI-2158 2.00 0.000 08-PIIA VT-3 86E-03 10/15/94 94U2-754P059 P

Y N

RIGID SUPPORT N/A ISI-PRI-2141 2.00 0.000 10-PilF VT-3 86E-03 09/29/94 94U2-754P020 P

Y N

RIGID SUPPORT N/A ISI-PRI-2156 2.00 0.000 11-Pile VT-3 86E-03 10/15/94 94U2-754P063 P

N RIGID SUPPORT N/A ISI-PRI-2156 2.00 0.000 4

12-PIIC VT-3 86E-03 09/27/94 94U2-754P013 P

Y N

RIGID SUPPORT N/A ISI-PRI-2155 2.00 0.000 12-PIID VT-3 86E-03 09/27/94 94U2-754P012 P

Y N

RIGID SUPPORT N/A ISI-PRI-2155 2.00 0.000 PAGE 8-1 i

Wisconsin Electric Power Company Point Betrh Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 COMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIPTION TYPE DATE SIIEET CREDIT TYP ITEM ISOMETRIC DIA.

TIIICKNESS RELIEF MATERIAL A & B

======================================_================================_==

i

' 12PSSB-2 VT-3 86E-03 09/30/94 94U2-754P027 P

Y N

RIGID SUPPORT N/A ISI-PRI-2138 2.00 0.000 13-PIIA VT-3 86E43 09/28/94 94U2-754P019 P

Y N

RIGID SUPPORT N/A ISI-PRI-2149 2.00 0.000 14-PIIA VT-3 86E-03 09/30/94 94U2-754P023 P

Y N

RIGID SUPPORT N/A ISI-PRI-2150 2.00 0.000 16-PII VT-3 86E-03 09/30/94 94U2-754P025 P

Y N

SPRING IIANGER N/A ISI-PRI-2140 3.00 0.000 17-211 42 VT-3 86E-03 10/08/94 94U2-754PO46 P

Y N

SPRING IIANGER N/A ISI-PRI-2228 8.00 0.000 20-211-02 VT-3 86E-03 10/04/94 94U2-754PO40 P

Y N

SPRING IIANGER N/A ISI-PRI-2231 6.00 0.000 U2R20/OUT2/ TOP OF LOAD SCALE LABEL TORN OFF.

PAGE 8-2

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No 50-301 Commercial Service Date 10/01/72 COMPONENT IDENTIFICATION METilOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIITION TYPE DATE SIIEET CREDIT TYP ITEM ISOMETRIC DIA.

TillCKNESS RELIEF MATERIAL A & B

===================================================_======================

24-Pli VT-3 86E-03 09/30/94 94U2-754P029 F

Y R

SPRING IIANGER VT-1 XO9-03 10/21/94 94U2-750P005 P

N N

N/A ISI-PRI-2146 2.00 0.000 U2R20/OUT2/ SPRING CAh LUGS ARE NOT PARALLEL.

25-Pli VT-3 86E-03 09/30/94 94U2-754P021 P

Y N

RIGID SUPPORT N/A ISI-PRI-2153 2.00 0.000 25-PRB VT-3 86E-03 10/10/94 94U2-754PO49 P

Y N

RIGID SUPIORT N/A ISI-PRI-2142 2.00 0.000 29-PRA VT-3 86E-03 10/15/94 94U2-754P067 P

Y N

RIGID SUPPORT N/A ISI-PRI-2151 2.00 0.000 29-PRD VT-3 86E-03 10/15/94 94U2-754P062 C

Y R

RIGID SUPPORT N/A ISI-PRI-2151 2.00 0.000 U2R20/OUT2/ WALL PLATE IIAS 3 GAPS AT BOTTOM OF PLATE.

PAGE 8-3

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 COMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND DOMPONENT DESCRIPTION TYPE DATE SIIEET CREDIT TYP jTEM ISOMETRIC DIA.

TilICKNESS RELIEF MATERIAL A & B

= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = - _ = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = _ = = = = = = = = = =

D9-PRE VT-3 86E-03 10/15/94 94U2-754P064 C

Y

~R kPRING IIANGER

/A ISI-PRI-2152 2.00 0.000 2R20/OUT2/2# BOLT LACKING TIIREAD ENGAGEMENT - SECOND BOLT FROM BOTTOM ON LEFT SIDE MISSING NUT - LOWER TIIREADED ROD AT ANGLE

'D liOLE SilOWS WEAR.

Ell-02B VT-3 86E-03 10/08/94 94U2-754PO47 C

Y R

PRING IIANGER VT-3 R034)3 10/30/94 94U2-754P077 P

N N

/A ISI-PRI-2253 10.00 0.000 2R20/OUT2/ ACTUAL LOAD IS IIIGIIER TIIAN REQUIRED RANGE.

EII-04A VT-3 86E-03 10/08/94 94U2-754PO45 C

Y R

PRING 11 ANGER

/A ISI-PRI-2252 10.00 0.000 2R20/OUT2/ GAPS BETWEEN 2 BOLT IIEADS AND PLATE - BOLT llEADS ARE BENT.

' II-06 VT-3 86E-03 10/04/91 94U2-754P037 P

Y N

PRING IIANGER VT-3 P20-03 10/04/94 94U2-754P037 P

N N

./A ISI-PRI-2223 8.00 0.000 11-0 8 VT-3 86E-03 10/04/94 94U2-754P036 P

Y N

PRING IIANGER

/A ISI-PRI-2224 8.00 0.000 l

PAGE 8-4

s Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72

OMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCRIPTION TYPE DATE SIIEET CREDIT TYP EM ISOMETRIC DIA.

TillCKNESS ELIEF MATERIAL A & B

= = = = = = = = = = = = = = = - = = = = = = = = = = = = = _ = = = = = = = = = = = = = = = - = = = = = = = = = = = = = = = = = - = = = = = = = = = = = = = = = = = = = =

II-IIS VT-3 86E-03 09/26/94 94U2-754P005 P

Y N

IGID SUPPORT

/A ISI-PRI-2333 8.00 0.000 VT-3 86E-03 10/04/94 94U2-754P035 P

Y N

(11-1 2 PRING IIANGER k/A ISI-PRI-2230 8.00 0.000 VT-3 R02-03 06/10/94 94U2-750P001 P

N N

l11-13B

'PRING II ANGER VT-3 P18-03 11/30/94 94U2-754P075 P

N R

/A ISI-PRI-2251 16.00 0.000 VT-3 86E-03 11/30/94 94U2-754P075 P

Y R

' E-EXAMINATION AFTER U-BOLT TIGIITENED AND SPRING CAN ADJUSTMENT PER IDR 93U2-7P012. U2R20/OUT2 IIANGER LUG IS BENT - ASSEMBLY ILTED - CIIANNEL IRON IS BENT.

11-2 8 VT-3 86E-03 10/04/94 94U2-754P034 P

Y N

PRING IIANGER

/A ISI-PRI-2232 6.00 0.000 (11-3 3 VT-3 86E-03 10/04/94 94U2-754P038 F

Y R

PRING IIANGER VT-3 R05-03 12/01/94 94U2-754P079 P

N N

h/A ISI-PRI-2220 10.00 0.000 12R20/OUT2/ ACTUAL LOAD IIIGIIER TilAN REQUIRED RANGE.

PAGE 8-5

1 Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 EOMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIPTION TYPE DATE SIIEET CREDIT TYP ITEM ISOMETRIC DIA.

TIIICKNESS RELIEF MATERIAL A & B

==========================================================================

311-OlB VT-3 86E-03 09/26/94 94U2-754P006 P

Y N

SPRING IIANGER N/A ISI-PRI-2270 6.00 0.000 A45 VT-3 86E43 09/30/94 94U2-754P026 P

Y N

ANCllOR N/A IS!-PRI-2122 0.00 0.000 A-11/M82 VT-3 86E-03 10/04/94 94U2-754P033 P

Y N

ANCIIOR N/A ISI-PRI-2242 6.00 0.000

.AC-06-SI-2001-15 l'T 86E-03 09/29/94 94U2-451P008 P

Y N

ELBOW TO PIPE UT 86E-03 09/30/94 94U2-161P002 C

Y G

B9.1I ISI-PRI-2129 6.00 0.562 SS U2R20/OUT2/ GEOMETRY IN ROOT AREA.

lAC-08-RIIR-2003-13 PT 86E-03 10/07/94 94U2-451P014 P

Y N

PEDUCER TO ELBOW E5. IIB ISI-PRI-2228 8.00 0.322 l

SS l

PAGE 8-6

Wisconsin Electric Power Company Point Benh Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 OMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCRIPTION TYPE DATE SilEET CREDIT TYP EM ISOMETRIC DIA.

TillCKNESS ELIEF MATERIAL A & B

= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = _ = = = = = = = - _ = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =

%C-08-RilR-2003-15 PT 86E4)3 10/07/94 94U2-451P013 P

Y N

{L5.11B LBOW TO PIPE ISI-PRI-2228 8.00 0.322 SS C-08-RIIR-2004-Il PT 86E-03 10/07/94 94U2-451P012 P

Y N

ALVE Ril-715B TO ELBOW

. IIB ISI-PRI-2229 8.00 0.322 SS C-10-RilR-2006-03 Irr 86E-03 09/28/94 9402-451P006 P

Y N

IPE TO ELBOW 5.1IB 151-PRI-2225 10.00 0.365 SS C-10-SI-2001-12 PT 86E-03 10/08/94 94U2-451P015 F

Y R

IPE TO ELBOW UT 86E-03 10/10/94 94U2-161P010 P

Y N

9.11 ISI-PRI-2124 10.00 1.000 Irr R04-03 10/14/94 94U2-451P028 P

N N

SS 2R20/OUT2/ UNDERCUT IN 3 AREAS AND 8 ROUNDED INDICATIONS.

VC-02-AS-2001-16B Irr 86E-03 10/12/94 94U2-451P022 P

Y N

OUPLING TO PIPE 9.40 ISI-PRI-2143 2.00 0.344 SS PAGE 8-7

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72

OMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND
OMPONENT DESCRIPTION TYPE DATE SilEET CREDIT TYP TEM ISOMETRIC DIA.

TIIICKNESS 1ELIEF MATERIAL A & B w=================._===================================================================

VC-02-LD-2001-40 PT 86E-03 10/14/94 94U2-451P027 P

Y N

>IPE TO ELBOW 19.4 0 ISI-PRI-2151 2.00 0.344 SS VC-02-LD-2001-42 PT 86E-03 10/14/94 94U2-451P025 P

Y N

DIPE TO ELBOW B9.40 ISI-PRI-2151 2.00 0.344 SS

VC-02-LD-2001-44 PT 86E-03 10/14/94 94U2-451P026 P

Y N

DIPE TO NOZZLE B9.40 ISI-PRI-2151 2.00 0.344 SS

VC-02-LD-2002-03 PT 86E-03 10/12/94 94U2-451P020 P

Y N

ELBOW TO PIPE B9.40 ISI-PRI-2144 2.00 0.344 SS

VC-02-LD-2002-07A PT 86E-03 10/12/94 94U2-451P021 P

Y N

TEE TO REDUCER B9.40 ISI-PRI-2144 2.00 0.344 SS s

PAGE 8-8

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 MPONENT IDENTIFICATION MET 110D EXAM EXAM EXAM DATA RESULTS PROGRAM IND MPONENT DESCRINION TYPE DATE SIIEET CREDIT TYP EM ISOMETRIC DIA.

TillCKNESS ELIEF MATERIAL A & B i=================================-======================_================:============

(VC-02-PSI-2002-21-FB VT-1 86E-03 10/15/94 94U2-750P004 P

Y N

1ANGE BOLTING 7.50 ISI-PRI-2148 0.00 0.000 S

VC-02-PSI-2002-23 PT 86E-03 10/15!94 94U2-451P030 P

Y N

EPE TO VALVE CV-304B 9.40 ISI-PRI-2143 2.00 7.344 SS (VC-03-Cil-2001-Il PT 86E-03 09/30/94 94U2-451P009 P

Y N

,LBOW TO PIPE 9.21 ISI-PRI-2140 3.00 0.438 SS A-EB-2-4 VT-3 B03-03 10/06/94 94U2-754P042 P

N N

HERGY ABSORBER NERGY ISI-PRI-2405 16.00 0.000 W-16-FW-2001-01 ARI UT P18-03 10/22/94 94U2-161P017 P

N G

JPE TO VALVE CS-466AA PT P18-03 10/15/94 94U2-451P038 P

N N

3.51 ISI-PRI-2249 16.00 0.843 CC r2R20/OUT2/ INTERMITTENT GEOMETRY AND ID INDICATION OUTSIDE AREA OF INTREST INTERMITTENT 360 DEG.

~

PAGE 8-9

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin $3201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 TOMPONENT IDENTIFICATION METl!OD EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCRilrTION TYPE DATE SilEET CREDIT TYP EM ISOMFTRIC DIA.

TillCKNESS LLIEF MATERIAL A & B

====================_.===._========u=======__===============================

'W-16-FW-2001-OlR1 l'T P18-03 10/15/94 94U2-451P039 P

N N

TALVE CS-466AA YO PIPE UT P1';-03 10/16/94 94U2-161P016 P

N N

5.51 ISI-PRI-2249 16.00 0.843 CC J2R20/OUT2/COUNTERBORE
W-16-FW-2001-22 MT 86E-03 10,06/94 94U2-350P004 P

Y N

!LBOW TO PIPE UT 86E-03 10/06/94 94U2-151P009 C

Y.

G

5.51 ISI-PRI-2250 16.00 0.843 CC J2R20/OUT2/ ROOT AND OD GEOMETRY.

W-16-FW-2002-01 AR1 PT P18-03 10/18/94 94U2-451PO40 P

N N

)lPE TO VALVE CS-476AA UT P18-03 10/24/94 94U2-161P020 C

N G

5.51 ISI-PRI-2251 16.00 0.843 PT P18-03 10/19/94 94U2-451PO42 P

N N

CC J2R20/OUT2/LAMINATIONS - POROSITY - INCLUSIONS.

'W-16-FW-2002-0I RI UT P18-03 10/24/94 94U2-161P019 P

N G

1ALVE CS-476AA TO PIPE l'r P18-03 10/18/94 94U2-451PO41 P

N N

5.51 ISI-PRI-2251 16.00 0.843 CC J2R20/OUT2/INTRMITTENT ID M OMETRY.

l t

PAGE 8-10

~,

t Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10S1/72 MPONENT IDENT21 CATION MET 110D EXAM EXAM EXAM DATA RESULTS PROGRAM IND MPONENT LCRIPTION TYPE DATE SIIEET CREDIT TYP EM ISOMETRIC DIA.

TillCKNESS LIEF M ATERIAL A & B

===================================_========__======_=====__==================__

16-FW-2002-17 MT 86E43 10i J/94 94U2-350P001 P

Y N

LVE CS-476BB TO ELBOW UT 86E-03 10/03/94 94U2-161P006 P

Y N

3.31 ISI-PRI-2251 16.00 0.843 t

CC M-16-FW-2002-19 MT 86E-03 10/03/94 94U2-350P002 P

Y N

(PE TO REDUCER UT 86E-03 10/03/94 94U2-161P007 P

Y N

3.51 ISI-PRI-2251 16.00 0.843 CC W-16-FW-2002-20 MT 86E-03 10/03/94 94U2-350P003 P

Y N

EDUCER TO NOZZLE UT 86E.03 10/03/94 94U2-161P008 P

Y N

'5.51 ISI-PRI-2251 18.00 0.843 UT B05-03 10/03/94 94U2-161P018 P

N N

CC HAMINATION TO INCLUDE COUNTERBORE TRANSITION REGION.

-09 VT-3 86E-03 09/26/94 94U2-754P010 P

Y N

RING IIANGER

/A ISI-PRI-2267 6.00

'12 VT-3 86E-03 09/26/94 94U2-754P001 C

Y R

BGID SUPPORT

/A ISI-PRI-2262 4.00 0.000 12R20/OUT2/ LOOSE NUT ON CLEVIS AND TURNBUCKLE SECURED WITil WIRE INSTEAD OF COTTER PIN.

PAGE 8-11

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West hiichigan Avenue 6610 Nuclear Road h1ilwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10S1/72 N1PONENT IDENTIFICATION h1ETTIOD EXAh!

EXAh!

EXAh! DATA RESULTS PROGRAh! IND N1PONENT DESCRilrTION TYPE DATE SIIEET CREDIT TYP 51 ISOh1ETRIC DIA.

TillCKNESS ELIEF hlATERIAL A & B

=========================================================__===============

-204B VT-3 86E-03 09/26/94 94U2-754P008 F

Y R

IGID SUPPORT VT-3 R064)3 10/27/94 94U2-754P070 P

N N

/A ISI-PRI-2259 4.00 0.000 2R20/OUT2/ PIPE CLEVIS LOOSE - NOT SUPPORTING PIPE.

-2063 VT-3 86E-03 09/26/94 94U2-754P009 C

Y R

IGID SUPPORT

/A ISI-PRI-2259 4.00 0.000 2R20/OUT2/ BENT TIIREADED ROD - FAST SIDE. WEST TOP CLEVIS PIN SECURED WITil WIRE INSTEAD OF COTTER PIN.

-210A VT-3 86E-03 09/26/94 94U2-754P015 F

Y R

IGID SUPPORT VT-1 P14-03 10/30/94 94U2-754P078 P

N N

' /A ISI-PRI-2261 4.00 0.000 2R20/OUT2/ LOOSE NUT ON U-BOLT.

-210B VT-3 86E-03 09/26/94 94U2-754P002 C

Y R

UIDE

/A ISI-PRI-2261 4.00 0.000 2R20/OUT2/U-DOLT h11SSING.

-43 VT-3 86E-03 10/17/94 94U2-754P066 P

Y N

IGID SUPPORT

/A ISI-PRI-2325 6.00 0.000 PAGE 8-12

Wisconsin Electric Power Company Point Betrh Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72

!OMPONENT IDENTIFICATION METilOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND

' MPONENT DESCRIPTION TYPE DATE SilEET CREDIT TYP M

ISOMETRIC DIA.

TillCKNESS ELIEF MATERIAL A & B

==========================================================================

B-19 VT-3 86E-03 10/12/94 94U2-754P057 P

Y N

IGID SUPPORT VT-3 P13-03 10/12/94 94U2-754P057 P

N N

/A 151-PRI-2329 8.00 0.000

'S-22 VT-3 86E-03 09/30/94 94U2-754P024 F

Y R

'UBBER VT-3 P15-03 10/28/94 94U2-754P071 P

N N

/A ISI-PRI-2135 3.00 0.000 f2R20/OUT2/ BOLT ON PIPE CLAMP TO SilORT - NUT IIAS INSUFFICIENT TilREAD ENGAGEMENNT.

S-36 VT-3 86E-03 10/18/94 94U2-754P069 P

Y N

UBDER

/A ISI-PRI-2201 0.00 0.000

,S-39 VT-3 86E-03 10/18/94 94U2-754P068 P

Y N

UBBER

/A ISI-PRI-2201 0.00 0.000 l

SS-06-MSR-2002-04 MT P194)3 10/25/94 94U2-350P019 P

N N

,IPE TO VALVE CV-2015 (5.51 A ISI-PRI-2248 6.00 0.280 l

CC

\\

l PAGE 8-13

Wiscensin Electric Power Company Point Beach Nuclear Plant, Unit 2 o

231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53231 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10!Oln2

'OMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCRIPTION TYPE DATE SIIEET CREDIT TYP EM

!SOMETRIC DIA.

TillCKNESS ELIEF MATERIAL A & B

= = = = = = = = = = = = = = = = = = = = = = =. -. = = = - = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =

jlS-30-MS-2001-II-BC MT 86E-03 10/04/94 94U2-350P008 P

Y N

LIM BRANCII CONN l5.31 ISI-PRI-2244 30.00 1.125 CC f2R20/OUT2/TilREE GOUGES NOTED ON Tile 6" CAP.

15-31-MS-2001-01 MT 86E-03 10/13/94 94U2-350P012 P

Y N

kOZZLE TO ELBOW UT 86E-03 10/14/94 94U2-161P015 C

Y G

5.51 ISI-PRI-2243 31.00 1.500 CC f2R20/OUT2/ INTERMITTENT OD GEONETRY.

S-31-MS-2G01-Ol LDI MT 86E-03 10/13/94 94U2-350P012 P

Y N

SIDE DOWNSTREAM LONG WELD UT 86E-03 10/14/94 94U2-161P015 P

Y N

5.52 ISI-PRI-2243 31.00 1.500 R-2-18 CC CS-31-MS-2001-OlLDO MT 86E-03 10/13/94 94U2-350P012 P

Y N

DUTSIDE DOWNSTREAM LONG WELD UT 86E-03 10/14/94 94U2-161P015 P

Y N

5.52 ISI-PRI-2243 31.00 1.500 (R-2-18 CC S-31-MS-2002-01 MT 86E-03 10/12/94 94U2-350P0ll F

Y R

[;OZZLE TO ELBOW UT 86E-03 10/13/94 94U2-161P013 P

Y N

3.51 ISI-PRI-2245 31.00 1.500 MT P16-03 10/22/94 94U2-350P013 P

N N

CC UT X11-03 10/22/94 94U2-104P001 P

N N

F2R20/OUT2/ TWELVE LINEAR INDICATIONS UPSTREAM OF WELD.

PAGE 8-14 I

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No 50-301 Conunercial Service Date 10?01/72 OMPONENT IDENTIFICATION METilOD EXAM EXAM EXA\\1 DATA RESULTS PROGRAM IND OMPONENT DESCRWTION TYPE DATE S1IEET CREDIT TYP EM ISOMETRIC DIA.

T111CKNESS ELIEF MATERIAL A & B

====_========_================_==========================._===========================.

BS-31-MS-2002-OlLDI MT 86E-03 10/12/94 93U2-350P0ll F

Y R

YSIDE DOWNSTREAM LOP G WELD UT 86E 03 10/13/94 94U2-161P013 P

Y N

5.52 ISI PRI-2245 31.00 1.500 R-2-18 CC 2R20/OUT2/ TWELVE LINEAR INDICATIONS UPSTREAM OF CIRC. WELD.

S-31-MS-2002-01LDO MT 86E-03 10/12/94 94U2-350P0ll F

Y R

iUTSIDE DOWNSTREAM LONG WELD UT 86E-03 10/13/94 94U2-161P013 P

Y N

5.52 ISI-PRI-2245 31.00 1.500 R-2-18 CC 2R20/OUT2/ TWELVE LINEAR INDICATIONS UPSTREAM OF CIRC. WELD.

R-SURGENOZ-SE PT 86E-03 10/18/94 94U2-451P034 P

Y N

AFE END TO NOZZLE UT 86E-03 10/20/94 94 U2-89-IP001 C

Y G

.40 ISI-PRI-2105 14.00 1.114 CS l2R20/OUT2/ID GEOMETRY.

-181 VT-3 86E-03 10/12/94 94U2-754P054 P

Y N

IGID SUPPORT VT-3 P12-03 10/12/94 94U2-754P054 P

N N

/A ISI-PRI-2332 8.00 0.000

-185 VT-3 86E-03 10/12/94 94U2-754P055 C

Y R

IGID SUPPORT VT-3

. P13-03 10/12/94 94U2-754P055 C

N R

/A ISI-PRI-2332 8.00 '0.000 12R20/OUT2/SIIIM IS 3/8" OFF CENTER.

PAGE 8-15

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01r/2 OMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCRIITION TYPE DATE SilEET CREDIT TYP EM ISOMETRIC DIA.

TillCKNESS ELIEF MATERIAL A & B t===_=========_============================================================-ae=========

-198 VT-3 Pl7-03 10/28/94 94U2-7540072 P

N N

IGID SUPPORT

/A ISI-PRI-2336 8.00 0.000

-199 VT-3 Pl74)3 10/28/94 94U2-754P073 P

N N

IGID SUPPORT

/A ISI-PRI-2336 8.00 0.000

-200 VT-3 Pl7-03 10/28/94 94U2-754P074 P

N N

IGID SUPPORT

/A ISI-PRI-2336 8.00 0.000

-205 VT-3 86E-03 10/12/94 94U2-754P056 P

Y N

IGID SUPPORT VT-3 P13-03 10/12/94 94U2-754P056 P

N N

/A ISI-PRI-2334 8.00 0.000

.-209 VT-3 Pl7-03 10/26/94 94U2-754P076 P

N N

.lGID SUPPORT 3/A ISI-PRI-2334 8.00 0.000

-2315 VT-3 86E-03 10/03/94 94U2-754P030 C

Y R

IGID SUPPORT

/A ISI-PRI-2269 6.00 2R20/OUT2/ CONCRETE CIIIPPED.

PAGE 8 16

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 lOMPONENT IDENTIFICATION METilOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCRIPTION TYPE DATE SIIEET CREDIT TYP FEM bOMETRIC DIA.

TillCKNESS lELIEF MATERIAL A & B

= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = _ _ = = = = - _ = = = = = = _ = = = = = = = = = = = = = = _ _ = = = = = = = = = = = =

-2334 VT-3 86E-03 10/04/94 94U2-754P039 P

Y N

IGID SUPPORT

/A ISI-PRI-2241 6.00 0.000

-30 VT-3 86E-03 10/08/94 94U2-754P048 P

Y N

IGID SUPPORT

/A ISI-PRI-2136 3.00 0.000

-41 VT-3 502-03 10/15/94 94U2-754P061 C

Y R

IGID SUPPORT

/A ISI-PRI-2225 10.00 0.000 s

l2R20/OUT2/ WALL ATTACllMENT IIAS GAP OF 1/8" X 31/2' AT BOTTOM OF PLATE - CONCRETE II AS 5' X 3/4" x 1/2' ClllP.

-42 VT-3 86E-03 10/15/94 94U2-754P058 P

Y N

IGID SUPPORT

/A ISI-PRI-2225 10.00 0.000

-72A VT-3 86E-03 09/28/94 94U2-754P018 P

Y N

IGID SUPPORT f/A ISI-PRI-2140 3.00 0.000 l

l C-02-BP-2003-19 FT 86E-03 10/15/94 94U2-451P029 P

Y N

.LBOW TO PIPE 9.40 ISI-PRI-2139 2.00 0.344 SS PAGE 8-17

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Asenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 1091/72

OMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND
OMPONENT DESCRIPTION TYPE DATE SiiEET CREDIT TYP

[ TEM ISOMETRIC DIA.

Til:CKNESS lELIEF MATERIAL A & B

u================_==-_===========================================================

f C-02-LD-2001-17 PT 86E-03 10/18/94 94U2-451P033 P

Y N

IPE TO ELBOW (9.40

!SI-PRI-2152 2.00 0.344 J

SS C-03-BP-2002-06 Irr 86E-03 10/08/94 94U2-451P016 P

Y N

IPE TO ELBOW

.21 ISI-PRI-2139 3.00 0.438 SS C-03-BP-2002-10 PT 86E-03 10/14/94 94U2-450P019 P

Y N

IPE TO PIPE

. 2I ISI-PRI-2139 3.00 0.438 SS C-04 VT-3 86E-03 09/27/94 94U2-754P0ll P

Y N

IGID SUPPORT

/A ISI-PRI-2132 6.00 C-04-DR-2004-02-FB VT-1 86E-03 09/30/94 94U2-750P002 C

Y R

NGE BOLTING

. 50 ISI-PRI-2120 0.00 0.000 S

J2R20/OOT2/ BORIC ACID DRY /WIIITE/LIGIIT BETWEEN FLANGE. GENERAL CORROSION ON STUDS. 2 NUTS ON PIPE SIDE - ONE T11 READ EXPOSED itSIDE NUT.

PAGE 8-18

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 OMPONENT IDENTIPICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCRINION TYPE DATE SilEET CREDIT TYP EM ISOMETRIC DIA.

TillCKNESS ELIEF MATERIAL A & B

= = = = = = = = = = = = = = = = = = = = = = = - = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = _ = = = = = =

C-10-AC-2001-01 M

86E-03 09/30/94 94U2-451P010 P

Y N

RANCil CONN TO ELBOW UT 86E-03 10/01/94 91U2-161P004 P

Y N

9. I 1 151-PRI-2122 10.00 1.000 SS

-15 VT-3 86E-03 10/10/94 94U2-754P050 C

Y R

PRING llANGER

/A ISI-PRI-2137 3.00 0.000 2R20/OUT2/ WELDLESS EYE NUT IIAS ONE TIIREAD SilOWING IN NUT.

-2112 VT-3 86E-03 09/30/94 94U2-754P028 F

Y R

RING ll ANGER VT-1 X10-03 10/21/94 94U2-750P006 P

N N

/A ISI-PRI-2138 3.00 0.000 2R20/OUT2/ SPRING CAN LUGS NOT PARALLEL.

i C-36-M RCL-Bil-04 PT 86E-03 10/17/94 94U2-451P032 P

Y N

LBOW TO PIPE UT 86E-03 10/18/94 94U2-167P001 P

Y G

.11 ISI-PRI-2121 36.00 3.000 SS 2R20/OUr'I.D. GEOMETRY SEEN INTERMITTENTLY 360 DEGRE'dS.

CP-A-LEG-1 VT-3 86E-03 09/30/94 94U2-754P022 P

Y N

OMPONENT SUPPORT

/A ISI-PRI-2108 0.00 0.000 l

C

=

PAGE 8-19 l

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West hiichigan Avenue 6610 Nuclear Road hiilwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 Oh1PONENT IDENTIFICATION 51ETIIOD EXAh!

EXAh!

EXAh! DATA RESULTS PROGRAh! IND MPONENT DESCRIPTION TYPE DATE SIIEET CREDIT TYP Eh!

ISOMETRIC DIA.

TillCKNESS ELIEF hf ATERIAL A & B

===_==================u==========__========================================

CP-LR-01 MT B01-03 10/25/94 94U2-350P016 P

N N

II T RIG SPREADER ASSY WELD CPMTR ISI-PRI-2403 0.00 0.000 CC 2R20/OUT2/ UNDERCUT VISUALLY NOTED.

IIE-01 UT 86E-03 10/12/94 94U2-166P001 N

N N

IEAD TO SilELL 2.51 ISI-PRI-2107 0.00 0.000 R-2-12 SS 2R20/OUT2/U-BOLT SUPPORT COVERING WELD EXAMINATION NOT PERFORMED.

IIE-02 UT 86E-03 10!!2/94 94U2-166P003 P

Y N

IIELL TO TUBESIIEET 2.60 ISI-PRI-2107 0.00 0.000 R-2-12 SS

' IIE-04 UT 86E-03 10/12/94 94U2-166P002 P

Y N

IIELL TO IIEAD i.20 ISI-PRI-2203 0.00 0.000 SS IIE-N1 UT 86E-03 10/12/94 94U2-If6P004 C

Y G

NLET NOZZLE TO SHELL 3.150 ISI-PRI-2107 0.00 0.000 R-2-12 SS 2R20/OUT2/ ROOT GEOMETRY.

PAGE 8-20

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No.50-30i Commercial Service Date 10/01/72 OMPONENT IDENTIFICATION METilOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCRII' TION TYPE DATE SilEET CREDIT TYP EM ISOMETRIC DIA.

TillCKNESS ELIEF MATERIAL A & B

= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = - _ = = = = - _ = = = = = = = = = = = = = = = =

Tile-N4 UT 86E-03 10/12/94 94U2-166P005 C

Y G

UTLET SilELL TO NOZZLE

.150 ISI-PRI-2107 0.00 0.000

  • R-2-12 SS 2R20/OUT2/ ROOT GEOMETRY.

1 IIE-SIIELL SUPPORT-1 VT-3 86E-03 10/12/94 94U2-754P051 P

Y N

OMPONENT SUPPORT

/A ISI-PRI-2107 0.00 0.000 C

IIE-SilELL SUPPORT-2 VT-3 86E-03 10/12/94 94U2-754P052 P

Y N

OMPONENT SUPPORT

/A ISI-PRI-2107 0.00 0.000 C

RIIE-SIIELL SUPPORT-3 VT-3 86E-03 10/12/94 9402-7541053 P

Y N

f0MPONENT SUPPORT N/A ISI-PRI-2107 0.00 0.000 C

JLIIR-A-LEG-1 VT-3 86E-03 10/07/94 94U2-754PO43 F

Y R

COMPONENT SUPPORT M/A ISI-PRI-2204 0.00 0.000 C

U2R20/OUT2/ GAP BETWEEN NUT AND PLATE.

PAGE 8-21

Wisconsin Electric Power Company Point Bezch Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10MI/72 OMPONENT ll'ENTIFICATION MET 110D EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCRIPTION TYPE DATE SHEET CREDIT TYP EM ISOMETRIC DIA.

TillCKNESS AELIEF MATF'AIAL A & B

===,==============u==============_-====================-_==========_========

PV-IID-CLAD VT-3 D01-03 10/06/94 94U2-755P001 P

N N

PV ilEAD INTERIOR CLADDING PVIIEAD ISI-PRI-2102 0.00 0.000 S

PV-IIFLANGE-A MT 86E-03 10/05/94 94U2-350P007 P

Y N

EAD TO FLANGE (AZ. 0-120)

UT 86E-03 10.'05/94 94U2-163P001 P

Y N

1.40 ISI-PRI-2102 157.25 5.750 CC IFT LUGS INTERFERE WITil EXAM.

PV-IILR.01 MT B01-03 10/05/94 94U2-350P005 P

N N

LEVIS PLATE TO LEG WELD PVilEAD ISI-PRI-2401 0.00 0.000 CC PV-IILR-04 MT B01-03 10/25/94 94U2-350P015 P

N N

ING GIRD-SUPPORT LUG WELD PVIIEAD ISI-PRI-2401 0.00 0.000 CC

~ PV-IILR-07 MT B01-03 10/25/94 94U2-350P014 F

N R

IDE LUG-SLING ASSY LINK WELD MT R07-03 10/28/94 94U2-350P020 P

N, N

PVilEAD ISI-PRI-'2401 0.00 0.000 CC J2R20!OUT2TIWO LINEAR INDICATIONS ON UPPER EDGE OF LUG.

PAGE 8-22

Wisconsin Electric Power Cornpany Point Beach Nuclear Plant, Unit 2 231 West hiichigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 OMPONENT IDENTIFICATION METilOD EXAM EXAM EXAM DATA RESULTS Dc O W IND TOMPONENT DESCRIIrTION TYPE DATE SIIEET CIL.

TYP TEM ISOMETRIC DIA.

TIIICKNESS lELIEF MATERIAL A & B

.==================================================-=============_====================

PV-IILR-08 MT B01-03 10/25/94 94U2-350P018 P

N N

l!DE LUG-SLING ASSY LINK WELD iPVliEAD ISI-PRI-2401 0.00 0.000 CC

^PV-IILR-09 MT B01-03 10/25/94 94U2-350P017 P

N N

IDE LUG-SLING ASSY LINK WELD kPVIIEAD ISI-PRI-2401 0.00 0.000 CC

' PV-IILUG41 MT B01-03 10/05/94 94U2-350P006 P

N N

' PV IIEAD LIFTING LUG PVilEAD ISI-PRI-2103 0.00 0.000 CC PV-INTERIOR VT-3 86E-03 10/01/94 94U2-755P003 P

Y N

ESSEL INTERIOR SURFACES

'I3.10 ISI-PRI-2101 132.00 0.000 SC PV-NUT-01 MT 86E-03 10/12/94 94U2-350P009 P

Y N

LOSURE NUT

.10 ISI-PRI-2103 8.50 7.875 C

PAGE 8-23

Wisconsin Electric Power Ccmpany Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenut 6610 Nuclear Road Milwaukee, Wisconsin 53263 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01U2 OMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND MPONENT DESCRIPTION TYPE DATE SIIEET CREDIT TYP ISOMETRIC DIA.

TillCKNESS ELIEF MATERIAL A & B

=================================================_========================

PV-NUT-02 MT 86E-03 10/12/94 94U2-350P009 P

Y N

LOSURE NUT 6.10 ISI-PRI-2103 8.50 7.875 C

PV-NUT-03 MT 86E-03 10/12/94 94U2-350P009 P

Y N

LOSURE NUT 6.10 ISI-PRI-2103 8.50 7.875 C

PV-NUT-04 MT 86E-03 10/12/94 94U2-350P009 P

Y N

LOSURE NUT 6.10 ISI PRI-2103 8.50 7.875 C

PV NUT-05 MT 86E-03 10/12/94 94U2-350P009 P

Y N

LOSURE NUT 6.10 ISl-PRI-2103 8.50 7.875 C

PV-NUT-06 MT 86E-03 10/12/94 94U2-350P009 P

Y N

LOSURE NUT 6.10 ISI-PRI-2103 8.50 7.875 C

PAGE 8-24 4

u

f Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 l

Docket No. 50-301 l

Commercial Service Date 10,T)l/72 OMPONENT IDENTIFICATION METilOD EXAM EXAM EXAM D ATA RESULTS PROGRAM IND OMPONENT DESCRIPTION TYPE DATE SilEET CREDIT TYP EM ISOMETRIC DIA.

THICKNESS

  • ELIEF MATERIAL A & B
==========================================================================

PV-NUT-07 MT 86E-03 10/12/94 94U2-350P009 P

Y N

SURE NUT

.10 ISI-PRI-2103 8.50 7.875 C

PV-NUT-08 MT 86E-03 10/12/94 94U2-350P009 P

Y N

LOSURE NUT

.10 ISI-PRI-2103 8.50 7.875 C

PV-NUT 4)9 MT 86E-03 10/12/94 94U2-350P009 P

Y N

LOSURE NUT 6.10 ISI-PRI-2103 8.50 7.875 C

PV-NUT-10 MT 86E-03 10/12/94 94U2-350POC9 P

Y N

LOSURE NUT

.10 ISI-PRI-2103 8.50 7.875 C

PV-NUT-11 MT 86E-03 10/12/94 94U2-350P009 P

Y N

LOSURE NUT 6.10 ISI-PRI-2103 8.50 7.875 C

PAGE 8-25

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear R.oad Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Cornertial Service Date 10/01/72 OMPONENT IDENTIFICATION METilOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCRIPTION TYPE DATE SilEET CREDIT TYP EM I5OMETRIC DIA.

TlilCKNESS ELIEF MATERIAL A & B

=========================================================================

JPV-NUT-;l MT 86E-03 10/12/94 94U2-350P009 P

Y N

ELOSUPE NUT D6.10 ISI-PRI-2103 8.50 7.875 C

[LOSURE NUT PV-NUT-13 MT 86E4)3 10/12/94 94U2-350P009 P

Y N

ISI-PRI-2103 8.50 7.875 B6.10 C

2 PV-NUT-14 MT 86E-03 10/12/94 94U2-350P009 P

Y N

LOSURE NUT B6.10 ISI-PRI-2103 8.50 7.875 C

2PV-NUT-15 MT 86E-03 10/12/94 94U2-350P009 P

Y N

LOSURE NUT B6.10 ISI-PRI-2103 8.50 7.875 C

9

' PV-NUT-16 MT 86E-03 10/12/94 94U2-350P009 P

Y N

LOSURE NUT

,6.10 ISI-PRI-2103 S.50 7.375 C

PAGE 8-26

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01T72 OMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCRIPTION TYPE DATE SilEET CREDIT TYP EM ISOMETRIC DIA.

TIIICKNESS

  • ELIEF MATERIAL A & B
===r=============-_===================================================_==
  • PV-STUD-01 MT 86E-03 10/12/94 MU2-350P010 P

Y N

LOSURE STUD UT 86E-03 10/04/94 94U2-160P001 P

Y N

.30 ISI-PRI-2103 6.00 56.625 C

PV-STUD-02 MT 86E-03 10/12/94 NU2-350P010 P

Y N

LOSURE STUD UT 86E-03 10/04/94 94U2-160P002 P

Y N

6.30 ISI-PRI-2103 6.00 56.625 C

' PV-STUD-03 MT 86E-03 10/12/94 94U2-350P010 P

Y N

LOSURE STUD UT 86E-03 10/04/94 94U2-160P003 P

Y N

.30 ISI-PRI-2103 6.00 56.625 C

PV-STUD-G4 MT 86E-03 10/12/94 94U2-350P010 P

Y N

LOSURE STUD UT 86E-03 10/04/94 94U2-160P004 P

Y N

6.30 ISI-PRI-2103 6.00 56.625 C

PV-STUD-05 MT 86E-03 10/12/94 94U2-350P010 P

Y N

1.OSURE STUD UT 86E-03 10/05/94 94U2-161P005 P

Y N

.30 ISI-PRI-2103 6.00 56.625 PAGE 8-27

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nucicar Rozed Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72

'OMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCRIPTION TYPE DATE SilEET CREDIT TYP EM ISOMETRIC DIA.

TIIICKNESS

=

=============================================================

PV-STUD-06 MT 86E-03 10/12/94 94U2-350P010 P

Y N

LOSURE STUD UT 86E-03 10/05/94 94U2-160P006 P

Y N

.30 ISI-PRI-2103 6.00 56.625 C

$PV-STUD-07 MT 86E-03 10/12/94 94U2-350P010 P

Y N

CLOSURE STUD UT 86E-03 10/04/94 94U2-160P007 P

Y N

M.30 ISI-PRI-2103 6.00 56.625 C

RPV-STUD-03 MT 86E-03 10/12/94 94U2-350P010 P

Y N

LOSURE STUD UT 86E-03 10/05/94 94U2-160P008 P

Y N

B6.30 ISI-PRI-2103 6.00 56.625 C

@PV-STUD-09 MT 86E-03 10/12/94 94U2-350P010 P

Y N

.LOSURE STUD UT 86E-03 10/05/94 94U2-160P009 P

Y N

B6.30 ISI-PRI-2103 6.00 56.625 C

PV-STUD-10 MT 86E-03 10/12/94 94U2-350P010 P

Y N

b".LOSURE STUD UT 86E-03 10/05/94 94U2-160P010 C

Y G

B6.30 ISI-PRI-2103 6.00 56.625 VT-3 X08-03 10/06/94 94U2-755P002 C

N G

C J2R20/OUT2iGEOMETRIC REFLECTOR - LAP AT FIRST TIIREAD.

PAGE 8-28

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Micaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 OMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCRII' TION TYPE DATE SHEET CREDIT TYP EM ISOMETRIC DIA.

TIIICKNESS gELIEF MATERIAL A & B 6===================================_=======================__==._,=====================

,2PV-STUD-Il MT 86E-03 10!!2/94 94U2-350P010 P

Y N

DLOSURE STUD UT 86E-03 10/05/94 94U2-160P011 P

Y N

Pl.30 ISI-PRI-2103 6.00 56.625 C

PV-STUD-12 MT 86E-03 10/12/94 94U2-350P010 P

Y N

LOSURE STUD UT 86E-03 10/05/94 94U2-160P012 P

Y N

.30 ISI-PRI-2103 6.00 56.625 C

PV-STUD-13 MT 86E-03 10/12/94 94U2-3500010 P

Y N

LOSURE STUD UT 86E-03 10/05/94 94U2-160P013 P

Y N

.30 ISI-PRI-2103 6.00 56.625 C

2PV-STUD-14 MT 86E-03 10/12/94 94U2-350P010 P

Y N

RLOSURE STUD UT 86E-03 10/06/94 94U2-160P014 P

Y N

$6.30 ISI-PRI-2103 6.00 56.625 C

kPV-STUD-15 MT 86E-03 10/12/94 94U2-350P010 P

Y N

'L UT 86E-03 10/06/94 94U2-160P015 P

Y N

k.OSURE STUD 30 ISI-PRI-2103 6.00 56.625 C

l l

PAGE 8-29

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 EOMPONENT IDENTIFICATION METilOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND TOMPONENT DESCRilrTION TYPE DATE SilEET CREDIT TYP TFEM ISOMETRIC DIA.

TillCKNESS RELIEF MATERIAL A & B

==================================_=======_============-=====================a

APV-STU D-16 MT 86E-03 10/12/94 94U2-350P010 P

Y N

CLOSURE STUD UT 86E-03 10/06/94 94U2-160PO16 P

Y N

36.30 ISI-PRI-2103 6.00 56.625 C

l PV-WAErl-01 VT-1 86E-03 10/12/94 94U2-750P003 P

Y N

LOSURE WASilER 16.50 ISI-PRI-2103 9.00 3.000 C

hPV-WASII42 VT-1 86E-03 10/12/94 94U2-750P003 P

Y N

ELOSURE WASilER 36.50 ISI-PRI-2103 9.00 3.000 C

IRPV-WASil-03 VT-1 86E-03 10/12/94 94U2-750P003 P

Y N

KLOSURE WASIIER t36.50 ISI-PRI-2103 9.00 3.000 C

j

$PV-WASil-04 VT-1 86E-03 10/12/94 94U2-750P003 P

Y N

LOSURE WASIIER

{6.50 1

ISI-PRI-2103 9.00 3.000 C

l l

PAGE 8-30

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers. Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 6

COMPONENT IDENTIFICATION METIlOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND

OMPONENT DESCRilrTION TYPE DATE SilEET CREDIT TYP VEM ISOMETRIC DIA.

TIIICKNESS 2ELIEF MATERIAL A & B

=======-==================================================u*

=========================

RPV-WAsil-05 VT-1 86E-03 10/12/9-+

94U2-750P003 P

Y N

!LOSURE WASIIER 06.5 0 ISI-PRJ-2103 9.00 3.000 C

PV-WASil-06 VT-1 86E-03 10/12/94 94U2-750P003 P

Y N

LOSURE WASIIER

.50 ISI-PRI-2103 9.00 3.000 C

hPV-WASII.07 VT-1 86E-03 10/12/94 94U2-750P003 P

Y N

2LOSURE WASIIER 06.50 ISI-PRI-2103 9.00 3.000 C

PV-WASil-08 VT-1 86E-03 10/12/94 94U2-750P003 P

Y N

LOSURE WASIIER

.50 ISI-PRI-2103 9.00 3.000 C

PV-WASif-09 VT-1 86E-03 10/12/94 94U2-750P003 P

Y N

DLOSURE WASilER D6.50 ISI-PRI-2103 9.00 3.000 C

PAGE 8-31

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 COMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIPTION TYPE DATE SIIEET CREDIT TYP ITEM ISOMETRIC DIA.

TillCKNESS RELIEF MATERIAL A & B

. = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = - _ = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =

RPV-WAsil-10 VT-1 86E-03 10/12/94 94U2-750P003 P

Y N

CLOSURE WASIIER

- B6.50 ISI-PRI-2103 9.00 3.000 C

RPV-WASii-11 VT-1 86E-03 10!!2/94 94U2-750P003 P

Y N

CLOSURE WASIIER B6.50 ISI-PRI-2103 9.00 3.000 C

RPV-WASil-12 VT-1 86E-03 10/12/94 94U2-750P003 P

Y N

CLOSURE WASIIER B6.50 ISI-PRI-2103 9.00 3.000 C

RPV-WASil-13 VT-1 86E-03 10/12/94 94U2-750P003 P

Y N

CLOSURE WASiiER B6.50 ISI-PRI-2103 9.00 3.000 C

RPV-WASil-14 VT-1 86E-03 10/12/94 94U2-750P003 P

Y N

CLOSURE WASilER B6.50 ISI-PRI-2103 9.00 3.000 C

PAGE 8-32

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers. Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10,101/72

-:OMPONENT IDENTIFICATION METilOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCRIPTION TYPE DATE SilEET CREDIT TYP VEM ISOMETRIC DIA.

TIIICKNESS

=====================================================================

$PV-WASil-15 VT-1 86E-03 10/12/M 94U2-750P003 P

Y N

CLOSURE WASiiER M.50 ISI-PRI-2103 9.00 3.000 C

PV-WASil-16 VT-1 86E-03 10/12/94 94U2-750P003 P

Y N

LOSURE WASIIER

%.50 ISI-PRI-2103 9.00 3.000 C

s 857B VT-3 86E-03 10/03/94 94U2-754P031 C

Y R

IGID SUPPORT

/A ISI-PRI-2262 4.00 0.000 J2R20/OUT2/APPROXIMATELY 1/16" GAP BETWEEN PIPE AND SUPPORT.

A-MAIN SUPPORT-4 VT-3 86E-03 10/17/94 94U2-754P065 P

Y N

MPONENT SUPPORT

/A ISI-PRI-2202 0.00 0.000 C

-B-MWAY-INLET-BLT-01 TIIRU 16 MT BM-03 10/13/94 94U2-353P001 P

N N

ANWAY BOLTING

.30 ISI-PRI-2202 0.00 0.000 C

PAGE 8-33

.. q.

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. '0-301 Commercial Service Date 10/01/72 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIPTION TYPE DATE SilEET CREDIT TYP ITEM ISOMETRIC DIA.

TIIICKNESS RELIEF MATERIAL A & B

======================================================.-=======-===========

SG-B-MWAY-OUTLET-BLT-01 TIIRU 16 MT B04-03 10/13/94 94U2-353P002 P

ti N

MANWAY BOLTING B7.30 ISI-PRI-2202 0.00 0.000 C

SI-08 VT-3 86E-03 09/27/94 94U2-754P014 P

Y N

RIGID SUPPORT N/A ISI-PRI-2131 6.00 0.000 BI-10B VT-3 86E-03 10/12/94 94U2-754PO44 P

Y I

TsIGID SUPPORT i3/A ISI-PRI-2129 6.00 0.000 U2R20iOUT2/ PIPE IS TIGIIT AGAINST ONE SIDE PENETRATION.

11-13 VT-3 86E-03 09/28/94 94U2-754P017 P

Y N

TsIGID SUPPORT

!i3/A ISI-PRI-2128 6.00 0.000 21-15 VT-3 86E-03 09/26/94 94U2-754P004 P

Y N

DIGID SUPPORT FS/A ISI-PRI-2255 2.00 0.000 SI-16 VT-3 86E-03 09/28/94 94U2-754P016 P

Y N

ulIGID SUPPORT W/A ISI-PRI-2255 2.00 0.000

[

..'.9,d 8-34 l

1 Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 4

l Commercial Service Date 10/01/72 t

COMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIPTION TYPE DATE SiiEET CREDIT TYP ITEM ISOMETRIC DIA.

TillCKNESS RELIEF MATERIAL A & B

==========================================================================

SI-27 VT-3 86E-03 10/03/94 94U2-754P032 P

Y N

RIGID SUPPORT N/A ISI-PRI-2254 2.00 0.000

'SI-33 VT-3 86E-03 09/26/94 94U2-754P007 C

Y R

RIGID SUPPORT N/A ISI-PRI-2257 2.00 0.000 U2R20/OUT2/ GAP BETWEEN NUTS AND SUPPORT.

S1-34 VT-3 86E-03 09/26/94 94U2-754P003 P

Y N

RIGID SUPPORT N/A ISI-PRI-2256 2.00 0.000 1

5154)2-51-2001-10 PT 86E-03 09/27/94 94U2-451P003 P

Y N

VALVE SI-845D TO PIPE B9.40 ISI-PRI-2154 2.00 0.344 SS s

515-02-S1-2001-17 PT 86E-03 10/12/94 94U2-451P023 P

Y N

I PIPE TO COUPLING B9.40 ISI-PRI-2154 2.00 0344 SS I

1 PAGE 8-35

-j

.. t 5

--.,----,--,---.w-<ww--n,---e.,

,--a-

,-w-

.----m

+-.r---

, r wemmm,-~,-n_c-

-n>w.

t, e-~-.s m

--nn-

-n-

---,-,,~+e--,-

-n-

,w,---n...

Wisconsin Electric Power Company Point Betch Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Conunercial Service Date 10/01/72 OMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND MPONENT DESCRIPTION TYPE DATE SIIEET CREDIT TYP EM ISOMETRIC DIA.

TIIICKNESS

?

ELIEF MATERIAL A & B

= = = = = = = = = = = = = = = = = _ = = = = = = _ = = = = = = = = = = = = = = = = = = = _ = = = = = = = - _ = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =

15-02-51-2008-38 PT 86E-03 10/06/94 94U2-452P0ll P

Y N

IPE TO ELBOW 5.30 ISI-PRI-2254 2.00 0.344 SS

'15-02-51-2013-01 PT 86E-03 09/27/94 94U2-451P004 P

Y N

6 E TO PIPE

.30 ISI-PRI-2265 2.00 0.344 SS 15-02-51-2014-03 PT 86E-03 06/27/94 94U2-451P002 P

Y N

PE TO ELBOW 5.30 ISI-PRI-2266 2.00 0.344 SS IS-04-SI-2001-57 PT 86E-03 10/10/94 94U2-451P017 P

Y N

IPE TO ELBOW UT 86E-03 10/13/94 94U2-161P014 P

Y N

5.21 ISI-PRI-2263 4.00 0.337 SS 15-04-51-2002-59 PT 86E-03 09/27/94 94U2-45iP005 P

Y N

IPE TO TEE UT 86E-03 09/29/94 94U2-161P001 P

Y N

.21 ISI-PRI-2264 4.00 0.337 SS l

PAGE 8-36

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 OMPONENT IDEN FICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND OMPONENT DESCullrTION TYPE DATE SilEET CREDIT TYP EM 1SOMETRIC DIA.

TIIICKNESS 4ELIEF MATERIAL A & B

==========================================================================

1S-06-51-2002-06 PT 86E43 10/13/94 94U2-451P024 N

N N

IPE TO ELBOW UT 86E-03 10/13/94 94U2-161P012 N

N N

.11 ISI-PRI-2131 6.00 0.562 SS 2R20/OUT2/ EXAMINATION CAN NOT BE PERFORMED DUE TO INTERFERENCE WITil SilUBBER 2115-23.

15-06-51-2002-07 Irr 86E-03 10/11/94 94U2-451P018 P

Y N

LBOW TO PIPE UT 86E-03 10/11/94 94U2-161P011 C

Y G

9.1I ISI-PRI-2131 6.00 0.562 SS 2R20/OUT2/ ROOT GEOMETRY.

s 91S 4 6-51 2006-12 PT 86E-03 09/26/94 94U2-451P001 P

Y N

ALVE SI 889R TO ELBOW UT 86E-03 10/03/94 94U2-161P005 P

Y N

5.11 131-PRI-2239 6.00 0.432 SS 15-10-51-2003-10 PT 86E-03 09/29/94 94U2-451P007 P

Y N

IPE TO ELBOW UT 86E-03 09/30/94 94U2-161P003 C

Y G

9.11 ISI-PRI-2126 10.00 1.000 SS 2R20/OUT2/ GEOMETRY IN ROOT AREA.

PAGE 8-37

_. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - - - -,. ~ ~ _ _.. _ _ _ _ _

~_,

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 COMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIPTION TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA.

TIIICKNESS RELIEF MATERIAL A & B

=======================================================_.==================

SLWIIX-LEG-2 VT-3 86E-03 10/05/94 94U2-754P041 C

Y R

COMPONENT SUPPORT N/A ISI-PRI-2205 0.00 0.000 CC U2R20/OUT2/ INCOMPLETE TIIREAD ENGAGEMENT AND CRACKED GROUT.

t o

.T 4

l i

l PAGE 8-38

'j' e

Wisconsin Electric Power Co.

231 West Michigan Avenue Milwaukee,WI 53201 Point Beach Nuclear Plant, Unit 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Commercial Service Date 10/01/72 3.4 Pressure Tests 3.4.1 ASME Section XI Pressure Tests Following are pressure tests that have been conducted as part of the pressure test program at PBNP since the last refueling outage.

4 h

l l

l l

I 1

l l

i l

Page 9 of 21

o Wisconsin Electne Power Co.

231 West Michigan Avenue Milwaukee,WI 53201 Point Beach Nuclear Plant, Unit 2 (410 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Commercial Service Date 10/01n2 Pressure Tests Page 10 of 21

j.

i Wisconsin Electric Power Co.

231 West Michigan Avenue Milwaukee, WI 53201 Point Beach Nuclear Plant, Unit 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Commercial service Date 10/01/72 TEST DESCRIPTION: System Irakage Test of Class 1 Components Following Refueling Outage.

System:

Reactor Coolant Test Document:

IT-235 Completion Date:

October 30,1994 i

1 Page 11 of 21

-2 WisconsinI.Jectric Power Co.

231 West Michigan Avenue Milwaukee,WI 53201 Point Beach Nuclear Plant, Unit 2 i

6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Commercial Service Date 10/01/72 3.5 Snubber Surveillance Tests 3.5.1 ASME Section XI Sn'.ibber Surveillance Tests Following are snubber inservice tests that have been conducted for snubbers less than 50 kips as part of the snubber surveillance test program at PBNP since the last refueling outage.

Page 12 of 21

1 Wisconsin Electric Power Co.

231 West Michigan Avenue Milwaukee, WI 53201 Po' t Beach Nuclear Plant, Unit 2 m

6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Conunercial Service Date 10/0102 Snubber Surveillance Tests 1

i Page 13 of 21

O o

Wisconsin Electric Power Co.

231 West Michigan Avenue Milwaukee, WI 53201 Point Beach Nuclear Plant, Urut 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Commercial Service Date 10/01n2 TEST DESCRIPTION: Snubber Inservice Test for Snubbers Less than 50 kips, Snubber:

IIS-25 Test Documents:

MWR 9406517 Completion Date:

October 10,1994 Results:

Acceptable i

Snubber:

HS-21 A Test Documents:

MWR 9406518 Completion Date:

October 25,1994

% Results:

Acceptable

\\

\\

h i

I

.i.

\\.

Page 14 of 21

F

...n

~

-_,.._..m.

Wisconsin Electric Power Co.

t 231 West Michigan Avenue Milwaukee, wl 53201 Point Beach Nuclear Plant, Unit 2 66au Mahar Road Two Rivers WI 54241 Docket 50-301 Commercial service Date 10/01n2 -

4.0 ABSTRACT OF CONDITIONS NOTED AND CORRECTIVE MEASURES TAKEN 4.1 Compone.nt/ Weld Nondestructive examinations were performed by QTS, EBASCO, and PWA personnel. The nondestructive examinations utilized VT, PT, MT, and UT techniques. All the examinations were performed in accordance with written procedures that conform to the applicaible sections of the ASME Boiler and Pressure Vessel Code. The following is a summary of the recorded indications found during the examinations and evaluated by WE personnel.

IDR 94U2-7P001, Class 2 RIGID SUPPORT,11-12 Data Sheet No. 94U2-754P001, Drawing No. ISI-PRI-2262 Indication:

I;>ose clevis nut, turnbuckle has wire instead of cotter pin Disposition: Accept as is This support was added to the LTP as a result of the Third Interval Program Upgrade and is the first time it was examined. The loose nut violates the acceptance criteria of IWF-3410(a)(2). The nut is not load bearing, it's only function is to prevent the threaded rod from falling out. The paint on the threaded rod prevents the nut from falling off. The nail in place of the cotter pin does not violate the acceptance criteria of IWF-3410. The support is operable, no additional or successive examinations are required.

IDR 94U2-7P002, Class 2 RIGID SUPPORT, SI-33 Data Sheet No. 94U2-754P007, Drawing No. ISI-PRI-2257 Indication:

Gap between nuts and support Disposition: Accept as is This support was added to the LTP as a result of the Third Interval Program Upgrade and is the first time it was examined. The loose nuts violates the acceptance criteria of IWF-3410(a)(2). The loose nuts are not load bearing and perform no function per the ITT Grinnell, PIPE IIANGER CATALOG PH81. The support is operable, no additional or successive examinations are required.

IDR 94U2-7P003, Class 1 SNUBBER, HS-22 Data Sheet No. 94U2-754P024, Drawing No. ISI-PRI-2135 Indication:

Nut lacks complete thread engagement Disposition: Replace bolt with longer one and reinspect Page 15 of 21

g

. r.

.~

..i~.,---......~.....s.u...-.'.

e Wisconsin Electric Power Co.

231 West Michigan Avenue Milwaukee,WI 53201 Point Beach Nuclear Plant. Unit 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Comrnercial service Date 10/0102 This condition does not violate the acceptance criteria of IWF-3410. The bolt and nut were tight but the bolt was too short to allow for complete thread engagement. MWR 9409467 (RRM 94-0071) was initiated to replace the bolt with one of sufficient length to allow for full thread engagement. No additionahor successive examinations are required.

IDR 94U2-7P004, Class 2 RIGID SUNORT, H-210A Data Sheet No. 94U2-754P015, Drawing No. ISI-PRI-2261 Indication:

Gap between nut and support Disposition: Tighten nut and reinspect This support was added to the LTP as a result of the Third Interval Program Upgrade and is the first time it was examined. The loose nuts violates the acceptance criteria of IWF-3410(a)(2). Further investigation revealed that the locknut was tight against the load bearing nut and that neither would turn, it is believed that this condition has existed since construction. MWR 9409294 (RRM 94-0060) was initiated tc tighten the load bearing nut and locknut to be in contact with the support. No additional or successive examinations are required.

IDR 94U2-7P005, Class 2 COMPONENT SUPPORT, SLWHX-LEG-2 Data Sheet No. 94U2-754P041, Drawing No. ISI-PRI-2205 Indication:

Incomplete thread engagement and cracked grout pad Disposition: Accept as is This component was added to the LTP as a result of the Third Interval Program Upgrade and is the first time it was examined. The incomplete thread engagement does not violate the acceptance criteria of IWF-3410. Further investigation revealed that the nuts were tight against the plate, the plate was tight against the grout pad and the nuts would not turn, it is believed that this condition has existed since construction. The cracked grout violates the acceptance criteria of IWF-3410(a)(1). The cracks appear to be due to shrinkage and pose no structural impact on the anchorage condition. The component is operable, no additional or successive examinations are required.

IDR 94U2-7P006, Class 2 COMPONENT SUPPORT, RHR-A-LEG-1 Data Sheet No. 94U2-754P043, Drawing No. ISI-PRI-2204 Indication:

Gap between nut and plete Disposition: Accept as is Paint on the anchor threads above and below the nut prevents the nut from turning, this provides evidence that the condition has existed since construction. The nut not being in Page 16 of 21

b,,

)

w.~.--..

Wisconsin Electric Power Co.

231 West Michipn Avenue Milwaukee,WI 53201 Point Beach Nuclear Plant. Unit 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Commercial service Date 10/01n2 contact with the plate violates the acceptance criteria of IWF-3410(a)(2). Condition report CR 94-465 was generated to evaluate the operability of this component. Further investigation revealed this condition had previously been identified as a result of the Seismic Verification project initiated due to NRC Generic Ixtter 87-02. At the time of initial l

identification, the condition was evaluated and found acceptable. This component is operable, no additional or successive examinations are required.

IDR 94U2-7P007, Class 2 SPRING IIANGER, 2H-02B Data Sheet No. 94U2-754P047, Drawing No. ISI-PRI-2253 Indication:

Actual load higher than required load range i

Disposition: Reset the load ard reinspect This condition violated the acceptance criteria of IWF-3410(a)(5). Evaluation identified that j

during U2R10 this hanger was inspected and the load was within the required range.

Further investigation revealed that MWR 90-0269 had been issued to reset the load to 3052#, die reason for this is unknown. Condition report 94-469 was initiated to document this condition. MWR 9409371 was initiated to reset the load midway in the range. This j

component is operable and no additional or successive examinations are required.

l IDR 94U2-7P008, Class 1 SPRING HANGER,24-PH Data Sheet No. 94U2-754P029, Drawing No. ISI-PRI-2146 Indication:

Spring can lugs not parallel Disposition: Accept as is This violates the acceptance criteria of IWF-3410(a)(1). Condition report CR 94-472 was initiated to determine the operability of the hanger. A VT-1 was performed on the lug attachment welds per the condition report, no indications were noted. This condition is a result of over tightening during initial installation. The hanger is operable and no additional or successive examinations are required.

IDR 94U2-7P009, Class 1 SPRING HANGER, RC-2H2 Data Sheet No. 94U2-754P028, Drawing No. ISI-PRI-2138 Indication:

Spring can lugs not parallel Disposition: Accept as is This violates the acceptance criteria of IWF-3410(a)(1). Condition report CR 94-473 was initiated to determine the operability of the hanger. A VT-1 was performed on the lug attachment welds per the condition report, no indications were noted. This condition is a Page 17 of 21 r

A O

e Wisconsin Electric Power Co.

231 West Michigan Avenue Milwaukee WI 53201 Point Beach Nuclear Plarm. Unit 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Commercial service Date 10/01n2 result of over tightening during initial installation. The hanger is operable and no additional or successive examinations are required.

IDR 94U2-7P010, Class 1 PIPE TO ELBOW weld, AC-10-SI-2001-12 Data Sheet No. 94U2-451P015, Drawing No. ISI-PRI-2124 Indication:

Undercut on the top and bottom of the weld and 8 rounded indications Disposition: Buff out indications and reinspect This condition violates the acceptance criteria of IWB-3514. Condition report CR 94-482 was initiated to determine operability of the system. MWR 9409373 (RRM 94-0068) was initiated to buff out the indications. The indications are fabrication related, no additional or successive examinations are required.

IDR 94U2-7P011, Class 2 SPRING HANGER,2H-33 Data Sheet No. 94U2-754P038, Drawing No. ISI-PRI-2220 Indication:

Actual load higher than required load range Disposition: Reset load and reinspect This condition violates the acceptance criteria of IWF-3410(a)(5). This component was added to the program as a result of the Third Interval program upgrade, and has not been previously inspected. Condition report 94-481 was initiated to document this condition and determine operability of the system. MWR 9409531'was initiated to reset the load midway in the range. This component is operable, no additional or successive examinations are required.

IDR 94U2-7P012, Class 2 RIGID SUPPORT, H-204B Data Sheet No. 94U2-754P008, Drawing No. ISI-PRI-2259 Indication:

Clevis not supporting pipe Disposition: Adjust clevis and reinspect This condition does not violate the acceptance criteria of IWF-3410. This component was added to the program as a result of the Third Interval program upgrade, and has not been previously inspected. Evaluation determined that the gap is acceptable as a gap < 1/16" is considered active in the piping analysis. MWR 9409524 was initiated to adjust the clevis to support the load of the pipe. This component is operable, no additional or successive examinations are required.

Page 18 of 21

F i

A..

s.

e Wisconsin Electric Power Co.

231 West Michigan Avenue Milwaukee.WI 53201 Point Beach Nuclear Plant. Unit 2 6610 Nuclear Road Two Rivers. WI 54241 Docket 50-301 Conunercial service Date 10/01/72 IDR 94U2-7P013, Class 2 RIGID SUPPORT, S-857B Data Sheet No. 94U2-754P031, Drawing No. ISI-PRI-2262 Indication:

1/16" gap between support and pipe Disposition: Accept as is This condition does not violate the acceptance criteria of IWF-3410. This component was added to the program as a result of the Third Interval program upgrade, and has not been previously inspected. Evaluation determined that the gap is acceptable as a gap < 1/8" is considered active in the piping analysis. This component is operable, no additional or successive examinations are required.

IDR 94U2-7P014, Class 1 SPRING IIANGER, RC-15 Data Sheet No. 94U2-754P050, Drawing No. ISI-PRI-2137 Indication:

Weldless eye nut lacking complete thread engagement Disposition: Accept as is This condition does not violate the acceptance criteria of IWF-3410. Evaluation revealed that this component was previously inspected during U2R10 with no indications recorded.

This type of condition was not required to be recorded during the previous inspection. Since the nut is tight, the load is within range, and no data exist that show evidence of loosening, it is believed that this condition has existed since construction. This component is operable, no additional or successive examinations are required.

IDR 94U2-7P015, DELETED IDR 94U2-7P016, Class 1 RIGID SUPPORT,29-PRD Data Sheet No. 94U2-754P062, Drawing No. ISI-PRI-2151 Indication:

Three gaps along the bottom of the plate were it meets the wall Disposition: Accept as is This condition violates the acceptance criteria ofIWF-3410(a)(1). Evaluation revealed this j

component was inspected during U2R10 with no recordable indications. Reporting criteria during the previous inspection did not require reporting of this condition. The gaps are located in 3 individual areas and not the entire length of the plate, they are also located lower than the projected line across the lower anchor centerline. The plate is in contact with the wall in the area of the anchors and the anchors are tight. This is a construction related deficiency. This component is operable, no additional or successive examinations are required.

Page 19 of 21

a a,___.-,..~.

_.c

+.

e Wisconsin Electne Power Co, 231 West Michigan Avenue Milwaukee, WI 53201 Point Beach Nuclear Plant, Unit 2 6610 Nuclear Road Two Rivers. WI 54241 Docket 50-301 Commercial service Date 10/01n2 IDR 94U2-7P017, Class 1 SPRING HANGER,29-PRE Data Sheet No. 94U2-754P064, Drawing No. ISI-PRI-2152 Indication:

Nut lacking full thread engagement, anchor missing the nut, lower rod is cocked at an angle, hole has evidence of wear.

Disposition: Accept as is This component was added to the program as a result of the third interval program upgrade, therefore no data exist to compare this condition to. The nut with incomplete thread engagement does not violate IWF-3410, sufficient thread engagement exist for the nut to perform it's function. The missing nut on the anchor violates the acceptance criteria of IWF-3410(a)(2). The missing nut was previously identified during the 79-02 program, as a result, a modification to the support adding a supplemental angle to the plate and anchoring it to the wall was performed. The cocked rod and hole with evidence of wear violates the acceptance criteria of IWF-3410. This component is operable, no additional or successive examinations are required. EWR 94-272 was initiated to further evaluate this support.

IDR 94U2-7P018, Class 2 NOZZLE TO ELBOW weld, MS-31-MS-2002-01 Data Sheet No. 94U2-350P011, Drawing No. ISI-PRI-2245 Indication:

Twelve linear indications upstream from the weld Disposition: Buff out indications and reinspect Nine of the linear indications violated the acceptance criteria of Table IWB-3514-2.

Evaluation determined that the linear indications were caused by tack welds from aligmnent bars that were used during fabrication. The tack welds created a localized high stress region that caused flaws to initiate and arrest the stress. MWR 9409503 (RRM 94-0072) was initiated to remove the flaws. This component is operable, no additional or successive examinations are required.

IDR 94U2-7P019, Class 3 RIGID SUPPORT, R-185 Data Sheet No. 94U2-754P055, Drawing No. ISI-PRI-2332 Indication:

Shim was 3/8" off center Disposition: Accept as is This condition does not violate the acceptance criteria of IWF-3410. This component is operable, no additional or successive examinations are required.

IDR 94U2-7P020, NON SECTION XI EXAMINATION Page 20 of 21

F L

w.- <

Wisconsin Electric Power Co.

231 West Michigan Avenue Milwaukee. WI 53201 Point Beach Nuclear Plant. Unit 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Commercial Service Date 10/0ln2 IDR 94U2-7P021, Class 2 RIGID SUPPORT, R-2315 Data Sheet No. 94U2-754P030, Drawing No. ISI-PRI-2269 Indication:

Chipped concrete were the embedded plate meets the wall Disposition: Accept as is The chipped concrete violates the acceptance criteria of IWF-3410(a)(1). This condition was previously identified and determined to be outsde the examination boundary of the support.

Condition report CR 95-020 was initiated to determine operability, root cause and track repairs if required.

IDR 94U2-7P022, Class 2 SPRING HANGER, 2H-13B Data Sheet No. 94U2-745P075, Drawing No. ISI-PRI-2251 Indication:

North hanger lug is bent, assembly is tilted, the channel beam under the pipe is bent Disposition: Accept as is The bent lug and channel violates the acceptance criteria of IWF-3410(a)(1). Evaluation determined that the lugs were bent during constmetion to allow for vertical clearance with other components, the channel is straight only the upper edge of the beam is bent approximately 1/32", During the previous inspections, insulation was installed which prevented this condition from being identified. The tilted assembly does not violate the acceptance criteria of IWF-3410. This component is operable, no additional or successive examinations are required.

4.2 Pressure Tests No reportable indications observed.

Page 21 of 21

r j

... ~..

--... ~ -. : ~. J... -.... w :- -

o FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code.' tules

1. Owner Wisconsin Electric Power Company. 231 W. Michican Ave.. Milwaukee WI 53201 (Name and Address of Owner)
2. Plant Point Beach Nuclear Plant. 6610 Nuclear Road. Two Rivers. WI 54241 (Name and Address of Plant)
3. Plant Unit 2
4. Owner Certificate of Authorization (if required) Docket 50-301
5. Commercial Service Date 10/01/72
6. National Board Number for Unit N/A
7. Components Inspected Component or Manufacturer or Manufacturer State or National Appurtenance Installer or Installer Province No.

Board No.

Serial No.

Reactor Pressure Vessel Combustior.

02741 U009973 NB 21009 Engineering Pressurizer Westinghouse 2T1 U009979 B Steam Generator Westinghouse 16A-6339-2 U009975 Seal Water ilX Atlas 700 NB 0564 f

Class 1 Piping System Westinghouse 1

Class 2 Piping System Bechtel i

i j

l NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 % in. x 1

11 in., (2) information in items I through 6 on this report is included en each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

1

)

1 (12/86)

This form (E00029) may be obtamed from the Order Dept., ASME,22 Law Drive, Box 2XK). Fairfield, NJ 07007-2300.

s

.......:...x_...-

o Sheet 2 of 2 q

FORM NIS-1 CONTINUED 8.

Examination Dates 9/24/94 to 11/1/94

9. Inspection Interval from 11/16/93 to 12/1/94
10. Applicable Editions of Section XI 1986 Addenda None
11. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval.

l Refer to attached Inservice inspection Final Report, Section 2.0.

12. Abstract of Conditions Noted.

Refer to attached Inservice Inspection Final Report, Section 3.0.

13. Abstract of Corrective Measures Recommended and Taken.

Refer to attached Inservice Inspection Final Report, Section 3.0.

We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable) NRC Docker 50-301 Expiration Date N/A Signed Wisc. Electric Power Co. By b < X [

Date January 20 19 95 Owner

[

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by llSBil. Co.

of flartford. CT have inspected the components described in this Owner's Report during the period November 16.1993 to December 1.1994

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions /0 78/, W/ 7ff.

I, AI

/ nspector's Signature Nanonal Board. State, Provmce and Endorsements

/

I Date SBAUMY lb 19 Vf

.