ML20078Q995

From kanterella
Jump to navigation Jump to search
Forwards Panthers Test Spec 23A6999,Rev 3.Document Specifies Requirements for Tests of full-scale Prototypes of Isolation Condenser & Passive Containment Cooling Condenser Designed for Use in Sbwr
ML20078Q995
Person / Time
Site: 05200004
Issue date: 02/15/1995
From: Quinn J
GENERAL ELECTRIC CO.
To: Borchardt R
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), Office of Nuclear Reactor Regulation
Shared Package
ML20078R003 List:
References
MFN-025-95, MFN-25-95, NUDOCS 9502220159
Download: ML20078Q995 (1)


Text

r 9

4 0

GENuclearEnemy J. E Quinn.

GeneralElectnc LMRandSBWk s Menacsr re:as 175 Curtner Avenue 165 San Jose. CA 95125-1014 408 925-1005 (phone) 408 025-3991 (facsimile)

February 15,1995 MFN No. 025-95 Docket STN 524)04 i

Document Control Desk j

U. S. Nuclear Regulatory Corninission i

Washington DC 20555 Attention:

Richard W. Borchardt, Director Standardization Project Directorate

Subject:

Transmittal of PANTHT.RS Test Specification 23A6999 Rev. 3.

Reference:

1) GEistter AffN 007-93 to the NRC, datedjanuary 18,1993.
2) GE1stter AllN 101-94 to the NRC, dated Augunt 31,1994.

Transniitted herewith is PANTilERS Test Specification 23A6999 Rev. 3. This revision supercedes the earlier versions sent in die above references.

This document specifies the requircinents for tests of full-scale prototypes of the isolation condenser (IC) and passive containment cooling (PCC) cond enser designed for use in the Simplified Boiling Water Reactor (SBWR). The purpose of the tests is to confirm the thermal hydrauhc and structural adequacy of the Ansaldo designed hardware for use in the SBWR.

This specification was revised to reflect as-tested conditions for the PCC tests. While the specification also covers IC testing, that portion ofit has not yet been updated to reflect changes in the test matrix discussed with the NRC staff. The specification will be revised again prior to IC testing later this year.

Sincerely,

/

Janu uinn, Projects Manager LMR and SBWR Programs

Enclosure:

PANTilERS Test Specification 23A6999 Rev. 3.

cc:

P. A. Boehnert (NRC/ACRS)

1. Catton (ACRS)

A. Drozd (NRC)

S. Q. Ninh (NRC)

J. I1. Wilson (NRC) 9502220159 950215 PDR ADOCK 05200004 y,

A PDR