ML20076M407
| ML20076M407 | |
| Person / Time | |
|---|---|
| Site: | Hatch |
| Issue date: | 06/29/1983 |
| From: | Stolz J Office of Nuclear Reactor Regulation |
| To: | Clark R Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML19268D962 | List: |
| References | |
| TAC-51054, NUDOCS 8307200358 | |
| Download: ML20076M407 (3) | |
Text
d;%
' JUNE 2 9 1983 HEMORANDUM FOR:
Robert A. Clark, Chief Operating Reactors Branch #3 Division of Licensing FROM:
John F. Stolz, Chief Operating Reactors Branch #4 Division of Licensing
SUBJECT:
REQUEST FOR PUBLICATION IN MONTHLY FR NOTICE - NOTICE OF ISSUANCE OF AMENDMENT TO FACILITY OPERATING LICENSE Georgia Power Company, Oglethorpe Power Corporation, Municipal Electric Authority of Georgia, City of Dalton, Georgia, Docket No. 50-366, Edwin I. Hatch Nuclear Plant, Unit No. 2, Appling County, Georgia.
Date of applications for amendment:
February 23, 1983, as supplemented April 19,1983; and March 30, 1983, as supplemented May 10,1983, May 20, 1983 and Hay 26, 1983.
Brief description of amendment: The amendment modifies the Technical Specifications to provide additional and revised trip setpoints that reflect design modifications to reduce containment loads from plant transients. The Technical Specification changes (1) lower the opening and closing setpoints for actuation of four safety relief valves following initial actuation of any one of the four valves, and (2) lower the main steam isolation valve water level trip setpoint.
It also modifies the Technical Specifications to reflect changes to the core design for the third fuel reload of Unit No. 2.
8307200358 830629 PDR ADOCK 05000366 P
PDR omce)
SURNOME) ocre )
OFFICIAL RECORD COPY usw. mi-ans NRC FORM 313 (10-80) NRCM 024a
a v
, r
\\?
1 Date of Issuance: June 29,1983 Effective Date: June 29,1983 Amendment No.: 33 Facility Operating License No.: NPF-5 Amendment revised the Technical Specifications.
Date of initial notice in Federal Register: May 18,1983, 48 FR 22389.
This Notice stated that we proposed a no significant hazards consideration determination for the licensee's March 30, 1983 amendment request concerning the cycle 4 fuel reload for Hatch Unit 2.
Supplemental letters related to this amendment request dated May 10, May 20, and May 26,1983, were received after issuance of Notica, and were, therefore, not considered 1
in the Notice. However, none of these supplemental letters affect our j
proposed determination as stated in the notice for the following reasons:
(1) our proposed determination that the reload amendment does not involve a significant hazards consideration was made on the basis that (a) the fuel elements for Cycle 4 that are different from elements previously f
approved for Hatch Unit 2 are of a design previously reviewed and approved l
for Hatch Unit 1, and (b) Hatch Unit 1 has operating characteristics that
)
l are not significantly different from Hatch Unit 2; and (2) the informa-1 tion submitted in the supplemental letters simply provided clarifying information related to fuel burnup and fuel corrosion failure considerations and additional Technical Specifications supporting the proposed Minimum
(
Critical Power Ratio limits.
l The Commission's related evaluation of the amendment is contained in a Safety Evaluation dated l
No significant hazards consideration comments received: No.
Source: N/A omce>
sunume>
DATE)
....*....**.....**a l Nac ronu ais oo-son uncu o24o OFFICIAL RECORD COPY usom im-mma
Local public document room location _: Appling County Public Library, 301 City Hall Drive, Baxley, Georgia.
John F. Stolz, Chief Operating Reactors Branch #4 Division of Licensing cc:
G. Rivenbark R. Ingram s
DISTRIBUTION:
. ~ ~ ~
Docket File RClark PKreutzer GRivenbark RIngram 1
fi4 al \\
w$ #j IN t~
4 y
- D.
,C-Q@,h,4;.RL..... 0 ELD. j u
s sunsauc >.RI.hgr.am.....
.GRiv.enbar.k:.c F....sto12.......
.... 2.7.A..
....../. 2.k.../. 8. 3......
... /..J...\\./. 83 6
...../. t.L/. 83 6
6
.. 6. /.....f. 8. 3........
1 DATE)
OFFICIAL RECORD COPY usom ini-mna Nac ronu ais oo-soj nacu ano