ML20070R933
| ML20070R933 | |
| Person / Time | |
|---|---|
| Site: | Brunswick |
| Issue date: | 05/16/1994 |
| From: | CAROLINA POWER & LIGHT CO. |
| To: | |
| Shared Package | |
| ML20070R932 | List: |
| References | |
| NUDOCS 9405230141 | |
| Download: ML20070R933 (16) | |
Text
.
ENCLOSURE 2 BRUNSWICK STEAM ELECTRIC PLANT, UNIT 1 AND 2 NRC DOCKETS 50-325 & 50 324 OPERATING LICENSES DPR-71 & DPR-62 REQUEST FOR LICENSE AMENDMENTS RESPONSE TIME TABLE RELOCATION TYPED TECHNICAL SPECIFICATION PAGES UNIT 1 l
l i
l l
E2-1 i
I 9405230141 940516 PDR ADOCK 05000324 P
PDR j
i
3/4.3 INSTRUMENTATION i
3/4.3.1 REACTOR PROTECTION SYSTEM INSTRUMENTATION l
LIMITING CONDITION FOR OPERATION l
3.3.1 As a min 4 mum, the reactor protection system instrumentation channels
- shown in Table 1.3.1 1 shall be OPERABLE. Set points and interlocks are given l
in Table 2.2.1 1.
l APPLICABILITY: As shown in Table 3.3.1 1, 4
m l
ACTION:
j a.
With the requirements for the minimum number of OPERABLE channels not satisfied for one trip system. place the inoperable channel (s) and/or trip system in the tripped condition
- within one hour.
b.
With the requirements for the minimum number of OPERABLE channels not-satisfied for both trip systems, place at least one trip system ** in-i the tripped condition within one hour and take the ACTION required by j
Table 3.3.1-1.
c.
The provisions of Specification 3.0.3 are not applicable in OPERATIONAL
]
CONDITION 5.
SURVEILLANCE REQUIREMENTS 4.3.1.1 Each reactor protection sy: tem.incta[meraation channel shall be i
demonstrated OPERABLE by the performance of the C'iANNEL CHECK. CHANNEL j
CALIBRATION and CHANNEL FUNCTIONAL TEST operations during the OPERATIONAL i
CONDITIONS and at the frequencies shown in Table 4.3.11.
4 4.3.1.2 LOGIC SYSTEM FUNCTIONAL TESTS and simulated automatic operation of all channels shall be performed " least once per 18 months and shall include calibration of time delay relays and timers necessary for proper functioning of the trip system.
4.3.1.3 The REACTOR PROTECTION SYSTEM RESPONSE TIME of each reactor trip function' shall be demonstrated to be within its limit at least once per 18 l
1 months.
Each test shall include at least one logic train such that both logic l
trains are tested at least once per 36 months and one channel per function such that all channels are tested at least once every N times 18 months where i
N is the total number of redundant channels in a specific reactor trip function.
J An inoperable channel need not be placed in the tripped condition where this would cause the Trip Function to occur.
In these cases, the inoperable channel shall be restored to OPERABLE status within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or the ACTION required by Table 3.3.11 for that Trip Function shall be taken.
If more channels are inoperable in one trip system than in the other, place the trip system with more inoperable channels in the tripped condition. except when this would cause the Trip Function to occur.
Neutron detectors are exempt from response time testing.
l BRUNSWICK - UNIT 1 3/4 3 1 Amendment No.
l I
This page intentionally deleted.
l l
i f
BRUNSWICK UNIT 1 3/4 3 6 Amendment No.
l l.
= -
l INSTRUMENTAT' ION 4
3/4.3.2 ISOLATION ACTUATION INSTRUMENTATION
' LIMITING CONDITION FOR OPERATION 1
3.3.2 The isolation actuation instrumentation channels shown in Table 3.3.21 i
shall be OPERABLE with their trip setpoints set consistent with the values j
shown in the Trip Setpoint column of Table 3.3.2 2.
l l
APPLICABILITY: As shown in Table 3.3.21.
ACTION:
j a.
With an isolation actuation instrumentation channel trip setpoint less conservative than the value shown in the Allowable Values column of Table 3.3.2 2. declare the channel inoperable and place the inoperable channel in the tripped condition until the channel is restored to OPERABLE status with its tri j
consistent with the Trip Setpoint value.p setpoint adjusted i
b.
With the requirements for the minimum number of OPERABLE channels -
t not satisfied for one trip system, place the inoperable channel (s)
]
and/or that trip system in the tripped condition
- within one hour.
4 c.
With the requirements for the minimum number of OPERABLE channels j
not satisfied for both trip systems, place at least one trip system **
i in the tripped condition within one hour and take the ACTION required-y by Table 3.3.2-1.
i d.
The provisions.of Specification 3.0.3 are not applicable in OPERATIONAL CONDITION 5.
1 l
SURVEILLANCE REQUIREMENTS i
4.3.2.1 Each isolation actuation instrumentation channel shall be j
demonstrated OPERABLE by the performance of the CHANNEL CHECK. CHANNEL CALIBRATION and CHANNEL FUNCTIONAL TEST operations during the OPERATIONAL j
CONDITIONS and at the frequencies shown in Table 4.3.21.
l 4.3.2.2 LOGIC SYSTEM FUNCTIONAL TESTS and simulated automatic operation of all channels shall be performed at least once per 18 months and shall include 4
calibration of time delay relays and timers necessary for proper functioning i
of the trip system.
}
l
}
An inoperable channel need not be placed in the tripped condition where this would cause the Trip Function to occur.
In these cases, the 2
inoperable channel shall be restored to OPERABLE status within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or the ACTION required by Table 3.3.21 for. that Trip Function shall be j
taken.
If more channels are inoperable in one trip system than in the other.
L place the trip system with more inoperable channels in the tripped condition, except when this would cause the Trip Function to occur.
4 1
BRUNSWICK UNIT 1 3/4 3 10 Amendment No, b
--.-w-
-n, e9.gq m--erye-4r7>+==w-ny_-m' p pm--tmee-w yr y sq - s 9.-awem g%*yi t 4,uf-rart-w'TT-f-
-weer*F--'
WPu
'9'-ft9@e"*W'*4*P-v*W 4'@freW*e'-d
-9
W'9"F**9'+-er-*"'
i INSTRUMENTATION SURVEILLANCE REQUIREMENTS (Continued)
'4.3.2.3 The ISOLATION SYSTEM RESPONSE TIME of each isolation function' shall i
be demonstrated to be within its limit at least once per 18 months.
Each test shall include at least one logic train such that both logic chains are tested i
at least once per 36 months and one channel per function such that all l
channels are tested at least once every N times 18 months where N is the total l
number of redundant channels in a specific isolation function.
- Radiation monitors are exempt from response time testing.
I i
I l
BRUNSWICK UNIT 1 3/4 3 11 Amendment No.
1 i
1, l
l i
i k
i
?
i I
i-1 1
2 Pages 3/4 3 23 through 3/4 3-26 have been intentionally deleted.
1 i
d f
3 4
i d
4 E
4 1
BRUNSWICK - UNIT 1 3/4 3 23 Amendment No.
f-INSTRUMENTATION j
3/4.3.3 EMERGENCY CORE COOLING SYSTEM ACTUATION INSTRUMENTATION i
LIMITING CONDITION FOR OPERATION j!
3.3.3 The Emergency Core Cooling System (ECCS) actuation instrumentation j
st.own in Table 3.3.31 shall be OPERABLE with their trip setpoints set consistent with the values shown in the Trip Setpoint column of Table 3.3.3-2.
I j
APPLICABILITY: As shown in Table 3.3.3-1.
1 l
ACTION:
l
,)
a.
With an ECCS actuation instrumentation channel trip setpoint less
)
J conservative than the value shown in the Allowable Values column of Table 3.3.3 2. declare the channel inoperable and place the inoperable channel in the tripped condition until the channel is i
restored to OPERABLE status with its trip setpoint adjusted consistent with the Trip Setpoint value.
b.
With one or more ECCS actuation instrumentation channels inoperable, take the ACTION required by Table 3.3.31.
c.
The provisions of Specification 3.0.3 are not applicable in OPERATIONAL CONDITION 5.
SURVEILLANCE REQUIREMENTS 4.3.3.1 Each ECCS actuation instrumentation channel shall be demonstrated OPERABLE by the performance of the CHANNEL CHECK CHANNEL CALIBRATION, and CHANNEL FUNCTIONAL TEST operations during the OPERATIONAL CONDITIONS and at the frequencies shown in Table 4.3.3 1.
4.3.3.2 LOGIC SYSTEM FUNCTIONAL TESTS and simulated automatic operation of all channels shall be performed at least once per 18 months and shall include calibration of time delay relays and timers necessary for proper functioning of the trip system.
4.3.3.3 The ECCS RESPONSE TIME of each ECCS function shall be demonstrated l
to be within the limit at least once per 18 months.
Each test shall include at least one logic train such that both logic trains are tested at least once l
per 36 months and one channel per function such that all channels are tested at least once every N times 18 months, where N is the total number of redundant channels in a specific ECCS function, l
I BRUNSWICK UNIT 1 3/4 3 33 Amendment No.
.... - - -. ~
I e
9
\\
l l
l This page intentionally deleted.
i l
t i
BRUNSWICK - UNIT 1 3/4 3 42 Amendment No.
ww-e ENCLOSURE 3 BRUNSWICK STEAM ELECTRIC PLANT, UNIT 1 AND 2 NRC DOCKETS 50-325 & 50-324 OPERATING LICENSES DPR 71 & DPR 62 REQUEST FOR LICENSE AMENDMENTS RESPONSE TIME TABLE RELOCATION 4
TYPED TECHNICAL SPECIFICATION PAGES - UNIT 2 E3-1
. _.. _ _.__ ~
ll' 3/4.3 INSTRUMENTATION i
3/4.3.1 REACTOR PROTECTION SYSTEM INSTRUMENTATION-q LIMITING CONDITION FOR OPERATION 4
3.3.1 As a minimum, the reactor protection system instrumentation channels 1
i shown in Table 3.3.11 shall be OPERABLE. Set points and interlocks are given I
i in Table 2.2.1 1, j
1 APPLICABILITY:
As shown in Table 3,3.1 1.
j ACTION:
J a.
With the requirements for the minimum number of OPERABLE channels not satisfied for one trip system, place the inoperable channel (s) and/or trip
{
system in the tripped condition
- within one hour.
b.
With the requirements for the minimum number of OPERABLE channels not i
satisfied for both trip systems, alace at least one trip system ** in the tripped condition within one lour and take the ACTION required by l
Table 3.3.1 1.
c.
The provisions of Specification 3.0.3 are not applicable in OPERATIONAL i
CONDITION 5.
SURVEILLANCE REQUIREMENTS 4.3.1.1 Each reactor protection system instrumentation channel shall be j
demonstrated OPERABLE by the performance of the CHANNEL CHECK, CHANNEL CALIBRATION and CHANNEL FUNCTIONAL TEST operations during the OPERATIONAL ~
j CONDITIONS and at the frequencies shown in Table 4.3.1 1.
4.3.1.2 LOGIC SYSTEM FUNCTIONAL TESTS and simulated automatic operation of l
all channels shall be performed at least once per 18 months and shall include calibration of time delay relays and timers necessary for proper functioning of the trip system.
4.3.1.3 The REACTOR PROTECTION SYSTEM RESPONSE TIME of each reactor trip i
function' shall be demonstrated to be within its limit at least once per 18 l
1 months.
Each test shall include at least one logic train such that both logic trains are tested at least once per 36 months and one channel per function i
such that all channels are tested at least once every N times 18 months where i
N is the total number of redundant channels in a specific reactor trip function.
4 An inoperable channel need not be placed in the tripped condition where this would cause the Trip Function to occur.
In these cases, the inoperable channel shall be restored to OPERABLE status within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or the ACTION required by Table 3.3.11 for that Trip Function J
shall be taken.
If more channels are inoperable in one trip system than in the other, j
place the trip system with more inoperable channels in the tripped I
condition, except when this would cause the Trip Function to occur, j
Neutron detectors are exempt from response time testing.
l l
d j
j BRUNSWICK UNIT 2 3/4 3 1 Amendment No.
I
This page intentionally deleted, l
i BRUNSWICK UNIT 2 3/4 3 6 Amendment No.
i
~
INSTRUMENTATION
'3/4.3.2 150LAT10N ACTUATION INSTRUMENTATTON i
LIMITING CONDITION FOR OPERATION 3.3.2 The isolation actuation instrumentation channels shown in Table 3.3.21 shall be OPERABLE with their trip setpoints set consistent with the values shown in the Trip Setpoint column of Table 3.3.2 2.
l l
APPLICABILITY: As shown in Table 3.3.2 1.
ACTION:
a.
With an isolation actuation instrumentation channel-trip setpoint less conservative than the value shown in the Allowable Values column of Table 3.3.2 2. declare the channel-inoperable and place 4
j the inoperable channel in the tripped condition until' the channel. is 1
restored to OPERABLE status with its trip setpoint adjusted consistent with the Trip Setpoint value. '
j 1
b.
With the requirements for the minimum number of OPERABLE channels i
not satisfied for one trip system, place the inoperable channel (s) y and/or that trip system in the tripped condition
- within one hour.
c.
With the requirements for the minimum number of OPERABLE channels l-not satisfied for both trip systems, place. at least one trip system **
in the tripped condition within one hour and take the ACTION required i
by Table 3.3.2 1.
I d.
The provisions of Specification 3.0.3 are not applicable in OPERATIONAL CONDITION 5.
i SURVEILLANCE REQUIREMENTS i
4.3.2.1 Each isolation actuation instrumentation channel shall be.
i demonstrated OPERABLE by the performance of the CHANNEL CHECK. CHANNEL CALIBRATION and CHANNEL FUNCTIONAL TEST operations during the OPERATIONAL i
CONDITIONS and at the frequencies shown in-Table 4.3.2 1.
i 4.3.2.2 LOGIC SYSTEM FUNCTIONAL TESTS and simulated automatic operation of all channels shall_be performed at least once per'18 months and shall include i
calibration of time delay relays and timers necessary for proper functioning i
of the trip system.
1 i
An inoperable channel need not be placed in the tripped condition where.
j this would cause the Trip Function to occur.- In these cases, the inoperable channel shall be restored to OPERABLE status within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or 4
i the ACTION required by Table 3.3.21 for that Trip Function shall be
]
taken.
If more channels are inoperable in one trip system than in the other.
place the trip system with more inoperable channels in the tripped condition, except when this would cause the Trip Function to occur.
J i
i BRUNSWICK UNIT 2 3/4 3 10 Amendment No.
INSTRUMENTATION SURVEILLANCE REQUIREHENTS (Continued) 4.3.2.3 The ISOLATION SYSTEH RESPONSE TIME of each isolation function' shall l
the demonstrated to be within its limit at least once per 18 months.
Each test shall include at least one logic train such that both logic chains are tested at least once per 36 months and one channel per function such that all channels are tested at least once every N times 18 months, where N is the total number of redundant channels in a specific isolation function.
1 i
i 1
' Radiation monitors are exempt from response time testing.
l l
BRUNSWICK UNIT 2 3/4 3-11 Amendment No.
l Q
l l
.I i
s j
i 4
2; Pages 3/4 3 2.3 through 3/4 3 26 have been intentionally deleted.
,i W
4 i
i i
l BRUNSWICK UNIT 2 3/4 3 23 Amendment No.
1 a
. -. +
n
-,nr
INSTRUMENTATION 3/4.3.3 EMERGENCY CORE COOLING SYSTEM ACTUATION INSTRUMENTATION LIMITING CONDITION FOR OPERATION 3.3.3 The Emergency Core Cooling System (ECCS) actuation instrumentation 4
shown in Table 3.3.31 shall be OPERABLE with their trip setpoints set consistent with the values shown in the Trip Setpoint column of Table 3.3.3 2. l APPLICABILITY: As shown in Table 3.3.3 1.
ACTION:
a.
With an ECCS actuation instrumentation channel trip setpoint less conservative than the value shown in the Allowable Values column of Table 3.3.3 2 declare the channel inoperable and place the inoperable channel in the tripped condition until the channel is restored to OPERABLE status with its trip setpoint adjusted consistent with the Trip Setpoint value.
b.
With one or more ECCS actuation instrumentation channels inoperable.
1 take the ACTION required by Table 3.3.3 1.
c.
The provisions of Specification 3.0.3 are not applicable in OPERATIONAL CONDITION S.
SURVEILLANCE REQUIREMENTS 4.3.3.1 Each ECCS actuation instrumentation channel shall be demonstrated OPERABLE by the performance of the CHANNEL CHECK. CHANNEL CALIBRATION. and 2'
CHANNEL FUNCTIONAL TEST operations during the OPERATIONAL CONDITIONS and at the frequencies shown in Table 4.3.31.
4.3.3.2 LOGIC SYSTEM FUNCTIONAL TESTS and simulated automatic operation of all channels shall be performed at least once per 18 months and shall include i
calibration of time delay relays and timers necessary for proper functioning of the trip system.
4.3.3.3 The ECCS RESPONSE TIME of each ECCS function shall be demonstrated to l be within the limit at least once per 18 months.
Each test shall include at least one logic train such that both logic trains are tested at least once per 36 months and one channel per function such that all channels are tested at least once every N times 18 months, where N is the total number of redundant channels in a specific ECCS function.
f BRUNSWICK UNIT 2 3/4 3 33 Amendment No.
J
This page intentionally deleted.
i BRUNSWICK UNIT 2 3/4 3 42 Amendment No.
._-