ML20070G507

From kanterella
Jump to navigation Jump to search
Deficiency Rept Re Welding Deficiencies in Chemical & Vol Control Sys Pump Supports.Initially Reported on 821129.Item Determined Not Reportable Per 10CFR50.55(e) & 10CFR21
ML20070G507
Person / Time
Site: Harris  Duke Energy icon.png
Issue date: 12/14/1982
From: Chiangi N
CAROLINA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
10CFR-050.55E, 10CFR-50.55E, CQAD-82-2132, NUDOCS 8212220345
Download: ML20070G507 (1)


Text

!

l t

.,,, e:

Carolina Power & Light Company

-Deepa% 14,1982

.a

.,p..

FILE: SH N-2/18 CQAD 82-2132 Item 107 Mr. James P. O'Reilly United States Nuclear Regulatory Commission Region II 101 Marietta Street, Northwest Atlanta, Georgia 30303 SHEARON HARRIS NUCLEAR POWER PLANT, UNITS 1 AND 2 DOCKET NOS. 50-400, 50-401 WELDING DEFICIENCIES IN CVCS PUMP SUPPORTS i

l

Dear Mr. O'Reilly:

This letter is to confirm the December 10, 1982 telephone conversation between Mr. N. J. Chiangi and Mr. A. Hardin.

Mr. Hardin was informed that the November 29, 1982 potentially reportable item pertaining to welding deficiencies in CVCS pump supports supplied by Dresser Industries of Huntington Park, California, has been evaluated and considered to be not reportable per the provisions of 10CFR50.55(e) and 10CFR, Part 21.

Thank you for your consideration in this matter.

Yours very truly, b

LL. _

1

.J.

Langi - Manager Engin ng & Construction Quality Assurance / Quality Control WTH/tbm (218) cc:

Mr. G. Maxwell Mr. V. Stello (2) r212220345 821214 PDR ADOCK 05000400 S

PDR bgC\\N' 411 Fayettevme Street

  • P. O. Box 1551
  • Raleigh, N. C. 27602 orm._

2 77 z.m.m, o

-- - - - - - -