OPERATING DATA REPORT DOCKET NO. 50-302 DAIE 6 /1/82 COSIPLETED BY n n n on c,.

TELEP110NE ron W 70s-6486 OPER ATING STATUS

1. Unit Name:

r'ry o n 1 n%r unir #3

2. Reporting Period:

5/1/82 - 5/31/82

3. Licensed Thermal Power (SIWt):

2544 890

4. Nameplate Rating (Gross SIWE):
5. Design Electrical Rating (Net 51We):

825

6. Staximum Dependable Capacity (Gross SlWe):

845

7. Slaximum Dependable Capacity (Net alWe):

806

8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report.Give Reasons:

N/A

9. Power Lesel To Which Restricted,if Any (Net alWe): Approximately 780 MWe (net).
10. Reasons For Restrictions. lf Any:

Restricted to 2300 MW thermal due to RC Pump Power Monitors being bypassed.

Net MWe corresponding to this varies with cycle efficiency.

This Slonth Yr..to.Date Cumulative

11. Ilours In Reporting Period 744 3624 45744 f
12. Number Of Ilours Reactor Was Critical 682.1 2675.8 28125.19
13. Reactor itesene Shutdown flours 11.8 15.7 1224.92
14. Ilours Generator On.Line 671.6 2641.5 27453.68
15. Unit Resene Shutdown llours 0

0 0

16. Gems Thermal Energy Generated (51Wil) 1530118 6087656 61454597
17. Gross Electrical Energy Generated (SIWil) 515412 2073284 20872875
18. Net Electrical Energy Generated (SIWil) 490210 1974158 19803456
19. Unit Service Factor 90.3%

_72.9%

60.0%

20. Unit Availability Factor 90.3%

72.9%

60.0%

21. Unit Capacity Factor IUsing SIDC Net) 81.7%

67.6%

55.2 %

22. Unit Capacity Factor IUsing DER Net) 79.9%

66.0%

52.5%

23. Unit Forced Outage Rate 9.7%

27.1%

26.6%

24. Shutdowns Scheduled Oser Nest 6 %1onths (Type. Date.and Duration of Each1:

None

25. If Shut Down At End Of Report Period. Estimated Date of Startup:

N/A

26. Units In lest Status t Prior to Commercial Operation);

Forecast Achiesed INill \\ l. C RillCAll I Y 1/14/77 INillT L El l C IltlCir Y 1/30/77 CO\\l\\ll'RCI \\1. OPI'It tIloN 3733j77 9206210101 820615 PDR ADOCK 05000302 R

PDR

\\

AVERAGE DAILY UNIT POWdR LEVEL DOCKET NO. Sn_ m UNIT FirRP-1 DATE 6/1/82 COMPLETED BY D. Bogart TELEPHONE (904) 795-6486 MONTil May 1982 DAY AVER AGE DAILY POWER LEVEL DAY AVER AGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net)

I 735 il 7

706 739 2

y3 705 3

19 0

4 733 20 0

5 741 21 247 714 6

761 22 7

742 23 711 8

728 24 729 9

730 752 25 10 26 11 742 27 745 12 717 746 28 732 13 733 29 14 753 30 324 15 730 730 3

784 16 INSTRUCTIONS On this format, hst the aserage daily unit power lesel in MWe-Net for each day in the reportnig inonth. Coinpute to the nearest whole megawatt.

i i

(9/77)

~ ~ - -

t UNIT SilUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-302 UNIT NAME FT PRP ~4 DATE 6/7/82 REPORT MONTil 5/82 COMPLETED BY M u entvor TELEPilONE (904) 795-6486 e.

O P1

  • J

'e jj g

fg3 Licensee 5-(

l%

Cause & Correciive s,'

g, ' #

3 y.5

.g g5e Event g7 Acijon in 3 7. j Rep"rt :

mO Preseni Recurrence OO g

6 82-11 820519 F

60.6 B

1 N/A CB MOTORX Shutdown to add oil to RCP-1D Motor, 82-12 820530 F

11.8 A

3 N/A HA xxxxxx Grounding brushes on turbine generatoo shaft had worn out causing arcing when the rocor position was being checked with a micrometer. The turbine generator trip mechanism was jarred causing a trubine, and there-by reactor, trip.

I 2

3 4

f: Forced Reason:

Method:

Exhibit G -Instructions S: Scheduled A. Equipment Failure (Explain) 1-Manual for Preparation of Data B. Maintenance of Test 2-Manual Scram.

Entry Sheets for Licensee C-Refueling 3 Automatic Senm.

Event Report (LER) File (NUREG.

D-Regulatory Restriction 4-Other (Explain) 0161)

{

E Operator Training & License Examination I'

F Administrative 5

G-Operational Error (Explain)

Exhibit 1 - Same Source N/77)

Il-Other (Explain) 9

9)

MONTIILY OPERATIONAL

SUMMARY

STATEMENT DOCKET NO. 50-302 UNIT FLCRP-3 DATE 6/7/82 COMPLETED BY M.W. Culver TE*". PHONE (904) 795-6486 -

MONTil May 1982 SUlfiARY STATDIENT: The unit performed at the restricted limit all month except for 2 minor outages.

i i

4 I

t 4-4 i

f