s TEXAS ENGINEERING EXPERIM ENT STATION THE TEXAS A&M UNIVERSITY SYSTEM

'~

^

^[

COLLEGE STADON. TEXAS 77843 DESIG

.- ORIGINAL

/

f...,

J l

C;rtified By_

dh.

IV i

16 April 1982 NUCLEAR SCIENCE CENTER 713/845-7 4

g e

On %

Mr. James R. Miller, Chief E

i] {p

-7 Standardization and Special Projects Branch y ce g{p[f, Division of Licensing g.

[j c.q t;f

[

U.S. Nuclear Regulatory Commission y

g Q: a!ji!

Washington, D.C.

20555

,ri t

t Ref:

Docket No. 50-128, R-83

~9 s

License Renewal Application for Class 104 Facility, Dated M

9

Dear Mr. Miller:

Enclosed is material which supercedes and supplements certain portions of the above referenced application.

Of particular interest is the first part of the supplement to the Safety Analysis Report which I hope will conclude our dis-cussion on our fuel damage situation. The second part of the supplement in-cludes changes and corrections to the earlier submittal, some of which are the result of the site visit by the consultants from Los Alamos. The additional material included are references which should facilitate the review of the fuel damage report.

I am looking forward to the opportunity of revising your prediction of a $2 limit.

Sincerely, o}O x

![

John D. Randall

'/ Director JDR/ym

Enclosures:

2 copies - Supplement 1 to the 1979 Safety Analysis Report 2 copies - Resubmittal of the Technical Specifications for the Nuclear Science Center Reactor Facility License R-83 2 copies - The U-ZrH Alloy:

Its Properties and Use in TRICA Fuel 2 copies - GA-A16613 - Interpre-ation of Damage to the FLIP Fuel During Operation of the Nuclear Science Center Reactor at Texas A&M University cc:

Dr. R. R. Berg, Chairman Reactor Safety Board g2,0 4 2 8 039 9 RESEARCH At:

'EVELOPMENT FOR MANKIND