38 ADMINISTRATIVE CONTROLS 6.8 PROCEDURES AND PROGRAMS 6.8.1 ' Written proce'dures shall be established, implemented and maintained covering the activities referenced below:

a.

The applicable procedures recommended in Appendix "A" of Regulatory Guide 1.33, Revision 2, February 1978.

b.

Refueling operations.

c.

Surveillance and test activities of safety related equ,ipment.

d.

Security Plan implementation!

e.

Emergency Plan implementation.

f.

Fire Protection Program implementation.

g.

PROCESS CONTROL PROGRAM implementation.

h.

OFFSITE DOSE CALCULATION MANUAL implementation.

' Quality Assurance Program for effluent and environmental monitoring, using the guidance in Regulatory Guide 4.15, February 197 6.8.2 Each procedure of 6.8.1 above, and changes thereto, shall be-rviewed -

by the PSRC and approv:d by.the Plant Manager prior to implementation and shall be reviewed periodically as set forth in administrative procedures.

6.8.3 Temporary changes to procedures of 6.8.1 above may be made p.rovided:

a.

The intent of the original procedure is not altered.

b.

~The change is approved by two members of the unit management staff, at least one of whom holds a Senior Reactor Operator's Licens.e on the unit affected.

c.

The change is documented, reviewed by the PSRC and approved by'the Plant Manager within 14 days of implementation.

6.8.4 The following programs shall be established, implemented, and maintained:

a.

Primary ' Coolant Sources Outside Containment A program to reduce leakage from those portions of systems outside ~

containment that could contain highly radioactive fluids during a serious transient or accident to as low as practical levels.

The systems include the:

RCICsystemoutsidecontainmentcontainingsteamorwaterf, 1.

exceptthedrainlinetothemaincondenser[.

2.

RHR syster outside containment containing steam or water, except the line to the LRW system and headers that are isolated by manual valves.

L HPCS system.

4.

LPCS system.

5.

Hydrogen analyzers of the combustible gas control system.

8204090363 820406 DR ADOCK 05000416 ua

, w-GRAND GULF-UNIT 1 6-13

.--