7- -

a

'Af Te ephone 1412) 393 6000 Nac# eor Group P O Boa 4 Shippmgport. PA 15077-0004 5

July 13, 1993 Dr. Gordon E. Edison Project Manager U.S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

Volume Control Tank Pressure Issue

Dear Dr. Edison:

Attached is the volume control tank rupture pressure calculation that you requested.

If you have any further questions on the subject

issue, please contact me at (412) 393-5210.

N.

R.

Tonet, P.E.

f Manager, Nuclear Safety i

JDC(2)/sao 1

Attachment t

i 4

I w

The Nuclear Professionals 1

9308130056 930726 PDR ADOCK 05000334.

l P

PDR i j

j

v' Fenn os u otta Duquesne Ught Company Analysis Sheet PAGE !

OF A JOB TITLE ZCWS-TC 2 2.

/ 'J CTh 2JW,.3 2 2 ANALYSIS NO I

P2r"LJeT O F E.

SUBJECT COMPILED BY /_o. MlJ'TFb7t:>

DATE, ! A ajy CHECKED BY DATE I

i DEPT./DIV, NED/

ML APPAOVED BY DATE x

.2%:.c T-

~.,,- ~ 2 u N E 2 a :' S

  • 22=

Ja; C ::

vcT

-A w V OuJ 70 twiC24Am P2cssvPc o u t.-/

t2rrt.ecsecs

\\. Z,oos. zso - cot - cos3 vcr Owc, 3

3 ycT D ATA ssCCT [3 %9 Z. 2003. In o - Oc t - 00 7 A N4 ATC2s ALS OF CONST*focT tCQ t

w 30est,S ? j h.50_

i. SMCL.A 4 H C A b 5 ;, T w ? ! 1:X SS, S A 2co, Sy 7

2. FA 32c4T Cc3

>c e. AsuG TU., W C, -2 00 0, 4 t t CD. Twitu S3.3hn 5.

3.1:'L.3 LL

2. ads 04 2AW C i: MC -,35
4. C)CStd=4 : "i f ?% if. IN.Tci A 15 PS c : Z;tTCEWAL, 250*F, WC COG!R. At4.0.J.

3

5. OPCRATtWc : 15 -f o P5tfa w r:.h WL,Ai.Aos extces*4,g it6'F c.. W e>eo : itt Pste. Ar top AT-70*i:

AssuuprowS

),

Fceuuc A.S t )ScD ABC FROM A S UC.IIT, N C 500o 1, wo E A FCM C: A c T O R.

3.

WWoe c w o f,,t d s d, T-9 cit. LcA cai%

4. ExTce at Pecssape ATuomtce.ic
5. Taur eut*rupes a=w 3

4 sr is ecacace>

L TOP-o y

le. C.YC4-\\ L I QADitJ4) t J OT" HC. A b%

p* - J d

COW 54 DCNC)

C.M2, T T

d r

,\\

pg o TMK,

~

'3\\ '

o.o..

=,

2Cas-Tezz.

  • A x

r

[NCNAL TY; j

l CfmS & No4, l

i btoT SNCLM) o

~ r

J eum

$ Duquesne Ught Company Analysts Sheet PAGE 1 M

or s

Ecus _TR12 [sJdT\\ '?.L3 PTU23 AN ALYSIS NO JOB TITLE P 2 CL'L.) e J.

OFE SUBJECT COMPILED BY 6. JC 'C2S DATE (., / 8" c.

CHECKED BY DATE i

DEPTs DfV.

,h APP 40VED BY DATE

  • A re _A T ' O ~

C O-Of4

$"* ? C L 'a N f 'l i.. 4 S D ' C/.4.,

N B.T t C 4 07 TAN a:l*,. [\\>cTwoo 30 ?

i

\\

ASMI. Z, NC -il24.S s b ' ? 2-w P *.

k ' SacA wtchcss pg.

5 -C 5P P=

N tchA Pass,s.;ps, psi S: ne t s g ar.- 4 s,--e:ss WTC. asst 1 t iusT-bm3 PS1

./t'* I.O l._T4 ELE.:.Mc.-3167-Ernt Dc544 iT P 55 INT;-tLTy (TAf%2.Z.-12.\\-

M. COO psi PC.%) 7 S.000 9 L t t,JkT'. -

I? ' h St M 2.Acit.35 CF CYL.,

. ____ _. 4

&c.APeA &xc*.

t { S - 0. 5 ?)'* ? %

S =IkSm*\\.O{SQ=%C 000 Nt.15,xO M.

i S - 0. St. *P = P 2

2. - E.4 - t/C.7.50D : 4 \\ ~15 IN.

- 0.5t?- P 2 ' H i S L

P(o.st+2}'t.S P = t. S o.st_k Perssuez Ar wi:LD sTe.:s s P = (o.7.s is.j 6.o 000 h ne h

==.

y m.t m.2.

.: __,I

~

C.litN.} 4 41.~151W.

PEC%Surec W t.J L Tt u A T E M H StL E S'TbE.% S

?*

(0.16

'15 000) 44 6 k' i

i u.

0.co.tsy4s.,s i

I Bar PORGI 3.171

Gom:

Duquesne Ught Company Analysis Sheet g

g PAGE OF 2.cu% - T< 7 7 / Vcr) et arituqc JOB TITLE ANALYSIS NO 9 Ec%L.)i?f O F E.

SUBJECT COMP! LED BY dm Ly. ? MeS DATE G f S'ag

/

CHECKED BY DATE DEPT /DIV.

APPAOVED BY DATE

+

3-.

CALC [COMT.)_

@ c.ACC :'

57ECLS N W BCS W CECAL WCADS, MCTWod PCit r.i.v : r t

e- =

8. r,2. N.

wc - 32. 24. 8)

Y = 0. h \\2 M.

L = r 7.L5N.

3=8cN.

E - c.17. o. 3D4 c, t = 8 r. L -

c. t o'S e o.1 o L

f.,7 1.5 D

84 L W 4)

UsN r.

AG. Nc - ? 7 24.C.- t t./L oc o. co44 N rtesc.c c o-ic 3

l-/ D = 0.1 0 cuevs AT A PPec%

P/S = c. cots j

.p--

... y e, P = c.coss sy = o.coes (w.coOh - 159 lb/s.z.

~

y Au c.

P - = o.cos'a 57 ' O. 006$

5,occh

~697 lb/i% E-T

'> Jct.us1 O M s

~

% knLt FAL 4 F i'0 9 3. W E C4 Li DEtcAt SuCLt. C D is, aucace er i se esie _ ucas ou_ r-uma c ucw u LTi w ie Tcsstt.c vtaqu6w4 1s W -tcd.

500P POmas 1171

{ C M $ = T C 2.2,,

VC.T) EU9N@O 2 E OSQ @3 2A[and 4 GP C ng. NC 322441 SECTION 111, DIVISION 1 - SUBSECTION NC

'*fA 0.10' i.

d f

l t

r 4%lr I

0 05 I

g~

^

i f

gy'

[/

I i

/

r/D 0.17(2:1 estipso.dal head)

/

0.10 l

l\\

'S

\\

E

\\ d z

0 01

\\

\\ i

\\MMwr i

1 I

\\

\\\\

M'M4M i

i

\\ \\ \\&MMf~r

~

r-a fM9

~

\\

X49 7#7Afff

~

i a=ss

0.,

1 jfffffpf J/

=

Dl2 7 f For 2.1 esiepsodel heads, use t

(

L = 0 90 to esicunste t/L

/)/

i i

7 l

t 0001 Dg l

0002 l

[

f 0.005 0.01 0.02 0.03 Op c.so< r.;

my gyg o.oo D $

FIG. NC-3224.6-1 DESIGN CURVES FOR TORISPHERICAL HEADS AND 2:1 ELLIPSOIDAL HEADS

[

FOR USE WITH NC-3224E AND NC-3224.6 M

o.ood c.

f

~ ~' - '.

gum i umi

=rur imummmm mumimummm P,