ML20044C971

From kanterella
Jump to navigation Jump to search
Forwards Catawba Nuclear Station Unit 2 Reactor Containment Bldg Integrated Leakage Rate Test Rept. Test Successfully Completed on 930207 Following Unit Shutdown for End of Cycle 5 Refueling Outage
ML20044C971
Person / Time
Site: Catawba Duke Energy icon.png
Issue date: 05/11/1993
From: Tuckman M
DUKE POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20044C973 List:
References
NUDOCS 9305140238
Download: ML20044C971 (1)


Text

-

II I

Duke Ibw Com;>any g5 n7,ya Cc :m t>a Nuriear Gtrieratior: Dr;,crimen:

ygg, pgggey 4 W Concord h%cd gay,83j.3 g5 ofyae brk SC2.*~45 pg3g3].34:5 fu i

DUKE POWER May 11,1993 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

Subject:

Catawba Nuclear Station, Unit 2 Docket No. 50-414 Reactor Containment Building Integrated Leak Rate Test Pursuant to 10 CFR, Appendix J, and Catawba Nuclear Station Technical Specification 4.6.1.2, find attached the Catawba Unit 2 Reactor Containment Building Integrated Leak Rate Test (ILRT) Report. The ILRT was successfully completed on February 7,1993 following unit shutdown for the end of cycle 5 refueling outage. Analysis of the data shows the results to be well within the appropriate limits.

Very truly yours,

.E W

M. S. Tuckman KEN /U21LRT.OC5 Attachment xc: S. D. Ebneter Regional Administrator, Region II W. T. Orders Senior Resident Inspector R. E. Martin, ONRR 14003G 9305140238 930511 I'g DR ADOCK 05000414 PDR n

n

_