L 18 NOVEMBER 1,1984 SERI shall complete the following requirements on the schedule noted below:
Emeroency Response Facilities (Generic letter 82-33, NUREG-0737 Supplement 1, 55ER #5)
SERI shall' implement the specific items below, in the manner described in MP&L letter (AECM-83/0232) dat'ed April 15, 1983, as modified in MP&L letter (AECM-83/0486) dated August 22, 1983, no later than the following specified dates:
(a) Safety Parameter Display System (SPDS)
(1) Submit a safety analysis and implementation July 1985 plan to the NRC (2) SPDS fully operational and operator trained Prior to startup following first refueling outage.
(b) Detailed Control Room Design Review (DCRDR)
(1) Submit a program plan to the NRC December 1984 (2) Submit a summary report to the NRC including July 1986 a proposed schedule for implementation (c) Regulatory Guide 1.97 - Application to Emergen:y Response Facilities (1) Submit a report to the NRC describing how the February 1985 requirements of Supplement 1 to NUREG-0737 have been or will be met.
(2) Implement (installation or upgrade)
Prior to startup requirements of R.G. 1.97 with exception following first of flux monitoring and coolant level monitoring.
refueling outage.
(3) Implement (installation or upgrade)
Prior to startup requirements of R.G. 1.97 for coolant level following second monitoring, refueling outage.
(4) Implement (installation or upgrade)
Prior to startua requirements of R.G.1.97 for flux monitoring.
following touch refueling ou age (d) Upgrade Emergency Operating Procedures (EOP's)
(
(1) Submit a Procedures Generation Package to the April 1985 NRC.