TENNESSEE VALLEY AUTHORITY l
CH ATTANOOGA. T ENN ESSEE 37401 400 Chestnut Street Tower II November 1, 1982 Director of Nuclear Reactor Regulation Attention:
Ms. E. Adensam, Chief Licensing Branch No. 4 Division of Licensing U.S. Nuclear Regulatory Commission Washington, D.C.
20555
Dear Ms. Adensam:
In the Matter of
)
Docket Nos. 50-327 Tennessee Valley Authority
)
50-328 We have provided, as Enclosure 1, our response to Thomas M. Novak's September 17, 1982 letter to H. G. Parris requesting additional information on hydrogen control for ice condenser plants. Also provided, as Enclosure is our response to your October 1, 1982 letter to H. G. Parris 2,requesting additional information on equipment temperature response to Also included in the response to the NRC question 2 of hydrogen burns. is a summary of the results of the Tayco igniter tests requested by NRC. This submittal responds to all of the outstanding NRC questions regarding hydrogen combustion and control and the associated hydrogen research program.
If you have any questions concerning this matter, please get in touch with J. E. Wills at FTS 858-2683 Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, nager Nuclear Licensing before me Sworn p#yd subscr o
th).es /
1L day of
/Mu 1982 Notar Public
,/
QQh f
My Core 11ssion Expires I,/
.V Enclosures cc:
U.S. Nuclear Regulatory Commission Region II Attn:
Mr. James P. O'Reilly, Regional Administrator 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 8211040294 821101 PDR ADOCK 0500G327 P
PDR An Ecua! Opportunity Employer
ENCLOSURE 1 RESPONSE TO THOMAS M. NOVAK'S SEPTEMBER 17, 1982 LETTER TO H. O. PARRIS REQUESTING ADDITIONAL INFORhATION ON HYDROGEN CONTROL FOR ICE CONDENSER PLANTS SEQUOYAH NUCLEAR PLANT
/
RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION ON HYDROGEN CONTROL FOR ICE CONDENSER PLANTS Question 1 A substantial number of laboratory tests were conducted as part of the ICOG-EPRI R&D Program for Hydrogen Control and Combustion. Test results were transmitted from the utilities to NRC as they became available. However, for several of the research programs, only selected test results were reported and organized compilations of all pertinent test information were not provided. This information is required to confirm the adequacy of the test program and assumptions made in the containment analyses. In this regard provide the following:
a) ACUREX i) A table of droplet size and droplet density estimates for each of the fog / spray tests.
ii) A table of estimated flame speed for each test (flame speed should be c'alculable from thermocouple locations and ignition time data),
iii) Pressure and temperature traces similar to those depicted in Figures 4-2 of the December 1981 Acurex Project Report, but for tests 2.10, 2.11, and 2.12.
b) FACTORY MUTUAL Results of ignition tests in which a glow plug was used in place of the ignition electrodes.
c) WHITESHELL Tables summarizing pre-and post-burn conditions, igniter locations, maximum measured pressure rise, adiabatic pressure rise, completeness of burn, and estimated flame speed. These tables should be keyed to and cover all of the tests committed to in the test matrix (Tables 1-4 in Appendix A.1 of the fourth quarterly report on the TVA research program, June 16,1981) plus any additional AECL tests conducted under this Of particular interest to the staff are the results of the 8.5%
program.
H test with 30% H 0 and top ignition. Discuss your plans for conducting p
p tests at steam concentrations above 305, as committed to in previous quarterly reports, d) HEDL Figures depicting concentration gradients 'for each of the tests. Figures provided should permit better resolution than those included in the previous submittal.
E72291.01
[
Rasponsa 1 a)(1) The Acurex test vessel was not instrumented to measure either the droplet size or density during the fog / spray tests. An estimate of these parameters may be made from data obtained by Factory Mutual for the Acurex nozzles and reported in Appendix A.5 of TVA's Quarterly Report No. 5 submitted January 22, 1982. However, it should be recognized that differences in vessel geometry and nozzle number and arrangement between Factory Mutual and Acurex would affect the fog / spray conditions present during the Acurex tests.
(ii) The Acurex test vessel was not instrumented to measure localized flame speeds. An estimate of an " average" global flame speed may be calculated from the pressure rise data of the type reported in Appendix A.4 of TVA's Quarterly Report No. 5.
Estimates of these
" average" flame speed ranges were reported in section IV.D of the technical summary which was attached to TVA's executive susmary report, submitted September 27, 1982.
(iii) Refer to Figures 1-1 through 1-6 for pressure and temperature responses from Acurex tests 2.10, 2.11, and 2.12.
b) The data from the Factory Mutual fog inerting tests, originally reported in Appendix A.5 of Quarterly Report No. 5, have been identified by igniter type in Tables 1-1 through 1-3.
c) Refer to Tables 1-4 through 1-6 for measured and calculated data from the Whiteshell CTF tests. The adiabatic pressure rises were not calculated and the flame speeds were not measured. However, the pressure rise time (t
which is the parameter of importance in estimating the speed at whI8N)the combustion event occurs, was measured and is included in the tables. The tables are keyed to the original numbers from TVA's Quarterly Report No. 4.
Note that some tests were altered from the original list in Quarterly Report No. 4, submitted September 22, 1981, as the research progressed, e.g., the steam concentrations in series 2 were revised upward to include tests at 40 and 50 volume percent. The omission of test QR N.1-19 (8.5% H, 305 steam, top ignition) was o
i inadvertent. The test will be perfohmed by early November (which is the i
earliest opportunity since other testing is currently underway at the l
Whiteshell facility). It should be emphasized that quite a few more CTF tests were actually performed than the number to which had been l
committed. In addition, numerous tests, including several with high l
steam concentrations in lean hydrogen mixtures, were performed in the Whiteshell small-vessel, igniter performance testing reported in Appendix A.2 of Quarterly Report No. 5.
i I
j d) Refer to Figures 1-7 and 1-8 for the maximum hydrogen (helium)
I concentration gradient transient data from each of the Hanford tests.
l The maximum difference reached a relatively steady state value during the g
release period for all tests. In addition, the maximum measured gradient I
during any test was less than 3 volume percent, except for tests HM-1A l
and HM-2.
These two tests were performed with no recirculation flow from the simulated air return fans. Following termination of the helium-steam source, the lower compartment pressure decreased below the upper E72291.01 9
e
l 04 4
1 ll D
f 2
1 08 0
1 0
2 0
T 9
e ru t
1 a
0 r 1
e e
1 e
p 1
2 m 0
s
(
e 2
e t T 7
r o
s u
g e e r
i T n i
T i
F lre s
0 tn e
C 4
5 0
6 3
0 8
1
.l.IL,.
!I!!s i
,iI
[!!!
, O 5
5 5
5 5
5 1
0 9
8 7
6 1
1 C E E'B e gEo,
il.
0 4
4 1
0 6
2 1
0 8
0
\\
1 0
0 9
)
ce 2
P 0
s 2
(
e 7
0 r e
2 u
m 1
s i
1 2 s T
e e
t r
r s P u
e g
T l
i e
F s
i 0 s
4 e
5 V
0
' 6 3
0 8
1 k
0 0
0 0
0 0
5 0
5 0
5 0
3 3
2 2
1 1
3S-5=[
\\
Figure 1-3 120 Test 2.11 Centerline Temperature T2
=
.'U O
80 -
~
e I
B e
at B
60 -
4 0--
i I
l 20' 1
O 100 200 300 400 500 600 700 800 900 Time (secI
T s
4 0
8 e
0 2
7 0
0 6
2P e
)
4 r
1 u
1 1
c s
e 2
s 0
s e
e t
r 8
(
ru s P 4
g e
e i
m T
l F
i e
T sse V
0 I
6 3
I 0
4 2
0 I
2 1
.r
.O 0
0 0
0 0
0 5
0 5
0 5
0 3
3 2
2 1
1 25 ?o M?c-2
I 0
0 4
1 0
i 0
2 1
l 0
00 1
00 8
)ce
/
s
(
em i
T 2
T i
0 0
e 6
ru t
M' I
0 a
r 5
2 e
p 1
m 1
2 e
e T
0 r
t 4
u s e g
e n i
T i F
lre tne C
0 I
0 2
~
p 0
0 0
0 0
0 2
0 8
6 4
1 GE 3Eo c*
b 0
6 2
1 08 0
1 0
0 9
2 P
)
e 6
c 2
r u
e 1
1 0
s s
(
2 s e
2 e
r 7
t r
e u
m s F g
i e
i T
T l
F esse V
' 0 4
5
' 0 6
3
' 0 8 1
~
0 0
0 0
0 0
0 5
0 5
0 5
0 3
3 2
2 1
1
]5 E5 u'
T MAXIMUM GAS CONCENTRATION DIFFERENCE FOR TEST HM-1A, HM-2, HM-4C, AND HM-6 o
8 0
C 0
L G
4 4
O 6
TEST Source Terminalion (Min.)
C" OC I) HM-1A 10.0
.- 0
.o O
- 2) HM-2 9.75 Oh S) HM-4C 10.75 g
- 1 4
C
,2
- 4) HM-6 10.75 G0 0E C3 2
o-
-3 d
2 e
<D e
2 N
3 x
o 7\\
4 O
5 10 15 20 25 30 35 40 Time.,
Minut.es FIGURE l-7
T MAXIMUM GAS CONCENTRATION DIFFERENCE FOR TEST HM-3A, HM-5A, AND HM-7 0
3 U
C e
L e
h
- %7 O
C#
OC 2
~
._ e
.a 0 HM-3A
?V
/
w o.
C eo
/
UE F
C3 o-00 g
8
/
O HM-5A E
~
a
^
x_-
b i
. ~. TMW.
~
3 I
0 0
5 10 15 20 25 30 35 40 9
- Time, Minut.es FIGURE l,8
r
, TABLE 1-1 l
PYDROCEN-WATER FOC INERTINC DATA AT 20 C Drop Size e,,3:g 20 Vol.
No.
Pressure Angle Mean Med i an Conc.
Igniter Hydrogen LFL Spray
(" I %)
!ozr l e (psig)
(Full)
(Micron) (Micron) e,3Hix 8.1x10-4 Spark 4.42 + 0.11 111 9.8 10
!;pra co 0.31 4.76 3 3.8x10-'
Spark 216I-7604 20 MO-
- 54. 5 4.7 O
2.7x10-'
Spark
- 4. 76 + 0. 31 44.1 3.8 0
25
~ 60 2.8x10-'
Spark 4.72 + 0.28 0
20.6 1.5 30
~60 2.8x10-4 Clow Plug 5.0 + 0.24 30
~6 0 20.6 1.5 3.ox10'3 Spark 4.64 + 0.12 10 61 139 13-0 Sprsco 8.5x10-'
Spark
-4.76 + 0.31 86.2 6.8 2020-1704 20 58.4 4.8~
2.9x10-'
Spark 4.76 + 0.31 25 1.5x10-'
Spark'
- 5. 2 6 + 0.1 '.-
30 80 35.7 5.6 9.4x10-5 Spark 4.40 + 0.lf 136 13 10 Spreco 6.0x10-5 Spark 4.76 + O.T 59.3 5
180 f.-1605 20 5.7x10-'
Spark 4.76 + 0.3 66 4
25 3.2x10-'
Spark 4.65 + 0.'l 30
~4 0 47.8 6.4 4.5x10-3 Spark
- 4. 64 + 0.1 136 14 Spraco 10 2.2x10-2 Spark 4.76 3 0.~
110 10' 140!-0604 20 "2.7x10-2 Spark 4.76 + 0.
114 11 (20-30 )
25 i
30 20 115 14 3.3x10 Spark 5.26 + 0.
-2 I
7.2
+ 0.
I 1.1x10-3 Spark i
5 Sonicore 20 03514
i TABLE 1-2 t
i HYDROCEN-WATER FOC INERTINC. DATA AT 50 C Drop Size Vol.
No.
c,31I2 Hydrogen LFL 0
Mean Median Conc. -
Igniter (vnt %)
sozzle (psi)
(Hieron).(Micron) c,Jggx Pre ss ure 1.4x10-4 Spark 7.19 + 0.22
'40 33.1 5.2 l
Spraco 8.1x10-5 Spark 5.55 + 0.11 1163-7604 30 21.4 4.2 1.9x10-4 Spark 5.55 + 0.11 20 34.5 4.5 9.3x10-5 Spark 7.1910.22 40 24.5 3.8 Spraco 1.1x10-4 Spark 7.19 + 0.22 27'.1
/.2 7020-1704 30 f
50.3 6.2 4.0x10
Spark 6.32 + 0.22 20 Glow Plug 4.9'S + 0.22 I
Spraco 10 9.7x10-5 Glow Plug 15.22 + 0.42
-1806-1605 20 43.2 1.6x10.5 Glow Plug 5.44 + 0.22 30
' 15.2 1.9x10-5 Glow Plug 5.18 + 0.42 11'.2 3
40 1.9x10-5 Spark 5.35 + 0.42 40 11.2 3
3.2x10-2 Spark 5.55 + 0.11 40 87.8 9.6 Spraco 2.0x10-2 Spark
- 5. 55 + 0.11 1405-0604 30 91.8 11.5 1.7x10-2 Sparti.
- 5. 55 + 0.11 25 115 14 1.tx10-3 Spark 7.93 + 0.23
- on i cor e 25 24 2.4 1.1x10-3
. Spark 7.19 + 0. 2 2 035H 20 24.4
- 2. 8 -
TABLE l-3 I
0 HYDROGEN-WATER FOG INERTING DATA AT ~70 C Nozzle Press.
Igniter Hydrogen LFL (psi)
(vol %)
Spraco,
10 Glow Plug-6.76
+ 0.22
~
2163-7604 20 Glow Plug 7.18
+ 0.22 30 Glow Plug 7.62
+ O.22 40 Glow Plug 8.46
+ 0.22 Spraco 10 Glow Plug 5.88
+ 0.21 1405-0604 20 Glow Plug 6.32
+ 0.21 30 Glow Plug 7.62
+ 0.21 40 Glow Plug 7.62 1 0.21 ee g.
I 0
0 e
e b
e l
TABLE 1-4 CTF EXPERIMENTAL SERIES 1 AND 3 l
l Exp. No.
Hydrogen Steam Air Fan dP t
Burn
)
Q.R. No.
CTF-(%)
(5)
(5)
(kPI)
(s% M (%)
1-1 101 5.0 0
95.0 off 13 9.5 a-20 12 102
~5.5 0
94.5 off 24 6.0
- 26 1-3 103 6.0 0
94.0 off 27 5.0 23 1-7 110 5.0 15 80.0 off 10 6.5 e' 20 1-8 111 5.0 15 80.0 off 8
7.0 a-20 1-9 124 R 5.0 30 65.0 off
~7 7.0,~ 20 1-4 123 6.2 0
93 8 off ~ 47 6.0 30 3-1 105 5.5 0
94.5 on 1 05 1.5
- 83 1-5 106 7.0 0
93 0 off 1 25 7.0 a 100 3-2 107 7.0 0
93 0 on 161 1.2 100 1_10,11 125 5.0 15 79.0 on 87 1.5 60 1-13,14 126 6.0 30 64.0 on 65 1.6 50 1-6 108 8.0 0
92.0 off 1 46 4.2 1 00 1_12 113 8.0 15 77.0 off 1 26 4.9 100 1-15 116 8.0 30 62.0 off 38 5.0 38 3-3 109 8.0 0
92.0 on 187 0.8 100 1_16 117 (CI) 7.0 0
93 0 off 1 10 11.4 100 1_17 118 (CI) 7.0 15 78.0 off 45 4.5
~0 118A (CI) 7.0 15 78.0 on 1 42 1.0 1 00 119 (CI) 10.0 0
90.0 on 2 15 0.53 1 00 3-7 120 (CI) 14.0 0
86.0 on 290(?) 0.4 1 00 CT 704 (TI) 11.0 0
89 0 on 2 25 0.6 1 00 CT 701 (TI) 8.0 0
92.0 on 180 0.9 100 1_18 CT 702 (TI) 8.5 0
91.5 off 1 57 3.2 1 00 CT 700 (TI) 7.0 0
93 0 on 1 45 1.1 1 00 CT 703 (TI) 57 0
94.3 on 75 1.9
~ 72
- CT 502 8.4 0
91.6 off 175
~ 100
- CT 501 10.0 0
90.0 off 2 60
~ 100
- CT 504 5.0 0
95.0 off 10 5.5
'TST 10 6.0 0
94.0 off 175
'TST 16 8.5 0
91.5 off 2 32
- TST 13 75 0
92 5 off 20
'TST 11 5.5 0
94.5 off 19 NOTES:
1.
All experiments initiallg at 100 C except thosa indicated with an "*"
were conducted at 28 1 2 C.
2.
Initial pressure 98 kPa.
3 All experiments are with bottom ignition except that those indicated with "CI" are with central ignition and those with "TI" are with top ignition.
E72291.01
1 1
l TABLE 1-5 CTF EXPERIMENTAL SERIES 2 AND 3 Exp. No.
Burn Q.R. No.
CTF-(%)
(5)
( 5)
H (%) (kPE)
(sE$Y (%)
2
==-- ___-------------
2-4 204 41.5 0.0 58.3 20.0*
403 0.07 56 230 41.6 0.0 58.4 19 75 4 24 0.06 59 203 32.6 0.0 67.4 6. 0*
452 0.06 84 222 36.5 0.0 63 5 13 0*
434 0.0.6 70 203A 31.0 0.0 69.0 2.4*
4 55 0.06 94 223 27.0 0.0 73 0 0.0 4 41 0.07 1 00 2-3 236 29.6 0.0 70.4 0.0 4 69 0.05 100 2-17 2 17 15.0 0.0 85.0 0.0 3 03 0.11 1 00 2-2 202c 20.0 0.0 80.0 0.0 390 100 2-1 201R 10.0 0.0 90.0 0.0 2 15 0.87 1 00 233 36.4 20.0 43 6 20.0*
3 31 0.12 50 2 32 24.6 20.0 55.4 1.58 369 0.12 93 219 25.0 20.0 55.0 2.25 359 0.18 92 2-12 2 12 35.5 20.0 44.5 19 0*
3 38 0.13 52 231 29.5
'0.0 70.5 0.0 4 62 0.05 1 00 2-5 205 11.0 10.0 79 0 0.0 2 16 0.72 1 00 2-7 2 37 30.0 10.0 60.0 5. 5*
4 10 0.09 84 2-9 209 10.0 20.0 70.0 0.0 1 59 2.40 1 00 2-13 213B 10.0 30.0 60.0 0.0 1 48 3.20 1 00 219B 10.0 40.0 50.0 0.0 1 12 6.10 1 00 2-10 2 10 16.0 20.0 64.0 0.0 293 0.27 1 00 219C 10.0 50.0 40.0 10.0 0.0 0
207 27.0 10.0 63 0 0.75 4 07 0.15 98 2-11 2 11 28.0 20.0 52.0 70*
365 0.13 78 2-14 2 29 21.0 30.0 49 0 0.5*
321 0.22 98 238 28.6 10.0 61.4 3.28 4 07 0.07 90 220(Bot Ign) 27.0 0.0 73 0 0.0 4 34 0.09 1 00 221 25.4 0.0 74.6 0.0 4 34 0.075 1 00 2-16 216A 30.4 30.0 39.6 15.08 255 0.45 55 214 15.6 30.0 54.4 0.0 2 55 0.60 1 00 4
2-15 2 34 29.0 30.0 41.0 13 0*
283 0.24 59 235 31.0 0.0 69 0 2.0*
4 63 0.05 94 2-18 218(Bot Ign) 20.0 0.0 80.0 0.0 3 86 0.14 1 00 226 22.2 30.0 47.7 2 5*
3 00 0.27 90 2-6 224 25.0 10.0 65.0 0.0 4 07 0.08 1 00 201R 10.0 0.0 90.0 -
0.0 210 0.80 1 00 3-8 207A (Fan) 27.0 10.0 63 0 0.5*
4 00 0.07 98 2-8 208 40.0 10.0 50.0 21.0*
345 0.11 53 3-10 3 10 20.0 0.0 80.0 0.0 3 59 0.09 100 3-6 308 (Fan) 7.0 0.0 93 0 0.0 1 45 1.50 1 00 3-4 306 6.0 0.0 94.0 3.0 55 5.50 51 i
)
3-9 309 15.0 0.0 85 0 0.0 283 0.24 1 00 307B(Bot Ign) 10 3 0.0 89 7 0.0 179 1.25 1 00 307A(Bot Ign) 11.5 0.0 87 9 0.0 186 1.00 100 3-5 307 (Bot Ign) 6.71 0.0 93 3 0.25 85 4.0 96 NOTES: (See second page)
E72291.01
c t
NOTES FOR TABLE 1-5
- = Calculated 1.
Initial temperature:
100 C 2.
Initial pressure: 98 kPa 3
Unless stated, experiments are with central ignition 4.
Experimental series 300 is with gratings l
1 l
1 6
l I
I t
I 1
I 1
i i
l E72291.01
I TABLE 1-6 CTF EXPERI} ENTAL SERIES 4 Exp. No.
H (Pipe) H (Sphere) AP t
Burn Q.R. No.
CTF-2 (5) 2 (%)
(kPE)
(ESE)
(%)
405 (EI) 10.0 10.0 2 48 6.75 100 402A (EI) 8.0 8.0 2 10
'14.75 100 Fan on 4-3 402A Fan off 8.0 8.0 10 16.0
~0 404 (EI) 6.5 6.5 1 15 23.0 70 Fan on 404 (EI) 6.5 6.5 2
24.0
~0 Fan off 4-4 401 (EI) 20.0 20.0 510 0.2 100 Fan off 41 407A (CI) 8.5 8.5 165 14.0 100 Fan off 409 (CI) 10.0 10.0 2 25 1.8 100 Fan off 42 408 (CI) 20.0 20.0 5 00 0.15 100 Fan off 410 (CI) 25.0 25.0 1300
.075 100 Fan off 411 (EI) 10.0 10.0 2 60 5.5 100 Constriction j
412 (EI) 20.0 20.0 5 25 0.2 100 W
Constriction 4-5 418 (EI) 12.0 6.0 105p,135s 1.1
~0 Burst Disk 4_6 419 (EI) 15.0 6.0 115p,115s 35p,.85s 70 Burat Disk 416 (EI) 15.0 10.0 120p,325s 0.28p,.375s 1 00*
Burst Disk 415 (EI) 15.0 20.0 120p,525s 0.32p,.4s 1 00
- Burst Disk NOTES:
- = Assumed 1.
All experiments at 24 3 2 C, 98 kPa.
2.
s = sphere, p = pipe 3
EI = pipe end ignition CI = sphere central ignition s
E72291.01
-,------7----
,,,,__..,--m--.-
_.,.-.___,____.__r.
compartm nt pr ssuro as the timperatura decrtaced and tha st:am in th2 compartment condensed. The resulting low pressure caused a reverse migration through the slots simulating the ice condenser doors which, coupled with a lack of mixing from the fans or the source jet, created a maximum concentration difference of 3 5 volume percent for test HM-1A and 7.5 volume percent for test HM-2.
The reverse flow condition which caused these high concentration differences was not prototypic of ice condenser containment conditions since the actual ice condenser is provided with doors which would simply close once the lower compartment pressure was no longer greater than the upper compartment pressure.
Therefore, the post-release concentration differences in tests HM-1A and HM-2 are considered to be anomalous due to the simulation of the ice condenser doors in the test vessel design.
5 l
t 1
I i
i t
E72291.01 i
n y-,
Question 2 The majority of the ICOG-EPRI tests which serve to demonstrate the validity of the deliberate ignition concept utilized a GMAC glow plug as the ignition source. TVA currently intends to install 120-V TAYC0 igniters in the Permanent Hydrogen Mitigation System instead of the glow plugs. Although igniter durability tests have been completed by Singleton, additional testing of the 120-V igniter is required to show that it is an acceptable replacement for the GMAC igniter. Specifically, a) Tests should be conducted to ensure that the igniter will continue to operate as intended in a spray atmosphere typical of that which would be expected in cach region of containment where igniters are to be located.
b) Endurance tests should be conducted on a suitable sample size, to assure adequacy and consistency of igniter surface temperature and lifetime.
Response 2 a) Tests have been conducted at TVA's Singleton Laboratory to ensure that the Tayco igniter assembly would continue to operate as intended in a typical containment spray atmosphere. The tests were conducted indoors in a room routinely used for spraying materials. The spray nozzle was a SPRACO hollow-cone nozzle (model No. 16711810) which was used in the utility-sponsored tests on the GM igniter at Fenwal, Inc. Several flow rates were tested at Singleton; the highest being 3.5 gal / min at 20 psid. The nozzle was oriented vertically downward and was located three feet above the igniter. The igniter was oriented horizontally and was mounted under a horizontal spray shield of the same configuration as the ones on the igniter assemblies to be installed in Sequoyan. The shield extended out over the igniter four inches from the mounting plate and was eight inches wide. The igniter extended about three inches out from the plate. In most of the tests, the igniter was 'sountsd ten inches below the shield to correspond with the lowest relative position in any assembly in the plant.
In the first test series, the initial igniter surface temperature varied 3
between 1700-17300F.
When the spray nozzle was actuated, the igniter temperature dropped to between 1650-16900F within about five minutes and remained relatively stable for the remaining 30 minutes of the test.
In the second test series, a large room fan was placed about five feet from the front of the igniter facing it along its axis. This forced turbulence was intended to simulate a potentially turbulent local containment environment and increase the spray cooling effect. The local air velocity measured at the igniter location due to the fan was 400
{
ft/ min 1 50. Again, the initial igniter surface temperature varied between 1700-17300F.
When the spray and fan were activated, the igniter temperature dropped to between 1600-1635 F within five minutes and remained stable for the remainder of the test.
i Even the 16000F surface temperature with the fan-induced turbulence is well above the 13500F surface temperature determined at Whiteshell to be the maximum required to ignite even lean hydrogen, rich steam mixtures.
(Refer to TVA's summary of Tayco igniter testing submitted l
June 14, 1982.) Therefore, we believe that the Tayco igniter assembly would function effectively in a representative containment spray l
environment.
i E72291.01 i
l
l
\\
b) In addition to the single Tayco igniter that previously underwent endurance testing at Singleton, three additional igniters have been tested. These three were each subjected to a series of five tests consisting of endurance and cycling.
The first test ccasisted of energizing the igniters continuously for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in an open room at 120-V ao to initially determine their surface temperature capability. The minimum surface temperatures recorded 0
following the initial warmup period ranged from 1715-1770 F.
Following the initial warmup test, the first of two endurance tests was performed. This test consisted of energizing the igniters for one week at 120-V ac to determine the surface temperature over an extended period. The average surface temperature of the three igniters during the test was between 1713-17420F and the minimum temperature was between 1683-17320F.
The gradual decrease in measured igniter surf' ce a
temperature during extended tests has been found to result from the use of spot-welded thermocouples as a measurement technique. When the thermocouples have been cleaned and re-welded to the igniter between test series, temperatures essentially the same as the initial temperatures are again measured. This indicates that some gradual deterioration of the thermocouple contact is probably occurring.
After the first endurance test, the third test consisted of cycling the igniters on/off 10 times each at 120,125,130, and 135-V ao to assess their durability under thermal cycling. In each cycle the igniters were energized for five minutes and then allowed to cool to ambient. Surface temperatures in excess of 17000F were reached within two minutes after the igniter was energized. The average peak surface temperature over ten cycles at 120-V ac varied from 1737-1773 F and over ten cycles at 135-V ac varied from 1838-19000F.
~
i The fourth test was the other endurance test in which the igniters were energized for one week at 135-V ac. During the seventh day of the test, one of the igniters failed to maintain an elevated temperature. The cause of failure has not been determined. The igniter had maintained an average surface temperature for more than 6 days of 18490F and a minimum temperature of 18260F before failure.
The other two igniters continued to function satisfactorily with an average surface temperature during the test between 1797-18630F and a minimum temperature between 0
1760-1841 F.
The final test was another cycling test similar to the first one with 10 cycles at each of the four voltages. The average peak surface temperature of the two igniters over 10 cycles at 120-V ac was between 1729-17740F and over 10 cycles at 135-V ao varied from 1850-1905 F.
Two of the three additional Tayco igniters successfully survived all of the conditions to which they were subjected and continued to perform.
The single failure occurred in the last day of a one-week test at 135-V ac. This voltage level is well above the normal expected voltage of 120-V ac which would be supplied at Sequoyah by the regulating transformer and, as such, is an extreme condition. In addition, the failed igniter successfully passed the initial 24-hour warmup test, the 7-day endurance test at the 120-V ao operating voltage, a set of thermal cycling tests at voltages up to and including 135-V ac, and over six days days of continuous operation at 135-V ac. Therefore, we believe that the Singleton tests on the additional Tayco igniters have shown that they are durable under endurance and cycling conditions.
E72291.01 l
Question 3 For the 120 V igniter system, describe the following:
I a) Performance characteristics of the igniters including surface temperature as a function of voltage and age.
b) A comparison of surface area, power density, and other relevant parameters for the original and currently proposed igniters.
c) Igniter mounting provisions.
d) Proposed preoperational and surveillance testing. If surveil. lance testing will be based on comparisons of measured voltage / current to preoperational values, specify the range for acceptance.
e) Power distribution system for the igniters, in particular, the location of the breakers in the system and the number of igniters on a breaker.
Response 3 a) Igniter surface temperatures measured as a function of voltage and age were reported in Attachment B of TVA's " Summary of Testing to Determine Suitability of Tayco Igniter for Use in the PHMS at Sequoyah and Watts Bar," submitted June 14, 1982. In addition, refer to response 2 of the present submittal.
b) Relevant parameters for the GM and Tayco igniter relate to performance -
the ability to ignite lean mixtures - and to durability. As reported in the submittal referenced in response 3(a), testing at Whiteshell showed that both the GM and Tayco igniters had the ability to ignite lean mixtures at their operating voltages. The two igniter types possessed similar lower ignition limits. The Tayco igniter minimum surface i
temperature required for ignition was measurably lower than the GM surface temperature. Also as reported in previous submittals and in response 2, testing at Singleton has shown that both the GM and Tayco igniters are sufficiently durable.
2 The GM igniter has a heated surface area of about 0.61 in and a power at 12-V ac pf 99 watts for a " calculated surface power density" of 162 wagts/in. The Tayco igniter has a heated surface area of about 10.9 in and a p wer at 120-V ac of 519 watts for a power density of 48 2
watts /in. The calculated surface power density for the Tayco igniter is lower due to the difference in heating element configuration of a coil compared to a rod. Based on the Whiteshell results discussed above, surface power density must not be closely related to igniter performance capability.
c) As shown in Figure 1 and described in the text of the submittal referenced in response 3(a), the Tayco igniter will be mounted in a NENM i
type 4 enclosure with the heating element protruding. The igniter body is threaded to accept a washer and nut to allow secure mounting in the enclosure. All electrical connections are made within the enclosure.
The entire assembly will be seismically supported.
l i
E72291.01
d) Preoperational and surveillance testing for the PHMS was described in response 1 of our December 1,1981, submittal. Preoperational testing will consist of energizing the system, measuring the surface temperature of each individual igniter, and recording the voltage and current in each igniter circuit. Later, during surveillance testing, the voltage and current of each circuit will be measured and compared with the readings previously recorded during the preoperational test. Since there are only two igniters in each circuit, the current measured during the surveillance test would drop by about half if one of the two igniters had failed. Such a major drop in current would be outside the range for acceptance in the test.
e) The power distribution system for the PHMS was described in Response 1 of our December 1,1981, submittal. In each train, power from the 480/120 V ac regulating transformer is routed to the 120 V ac distribution panel located on elevation 759 of the auxiliary building. The distribution panel for each train contains 16 separate circuits, each providing power to two igniters and including a circuit breaker.
E72291.01
Question 4 Provide details regarding the number and location of permanent igniters in containment. Discuss the influence of considerations such as volume served per igniter and preferred flame direction on the design of the permanent sys tem.
Response 4 A description of the numoer and location of igniters in the PHMS was provided in 29sponse 1 of our December 1,1981, submittal. Since that time, the location of the igniters in the ice condenser upper plenum has been changed to allow the assemblies to be seismically mounted. The upper plenum igniters on the crane wall side will be located at elevation 785 and the igniters on the containment wall side at about elevation 792.
As discussed in previous submittals, igniters are distributed throughout the major regions of containment in which hydrogen could be released or to which it could flow in significant quantities. No specific consideration was given to the " volume served" per igniter. Igniters in both the upper and lower i
compartment are located at intermediate as well as high elevations to allow the partial burning that would accompany upward flame propagation.
G I
E72291.01 s
_-..___.__-___-,_,m c
m.,
Question 5 Recent tests conducted at McGill indicate that flame accelerations accompanied by large pressure increases, and detonations can occur at i
hydrogen concentrations as low as 135 Although remote, the possibility of I
flame accelerations and local detonations occurring around obstacles and in confined regions of containment cannot be entirely dismissed. Further analysis of the probability and consequences of these events are thus warranted. In this regard:
a) Discuss the chain of events and conditions required to cause flame accelerations and detonation in containment, and the probability that such conditions might exist. Identify the locations in containment at which flame acceleration / detonation would most likely occur.
t b) Provide quantitative estimates of the extent and magnitude of' flame 3
acceleration in containment and the resulting pressure increase and loads on structures and equipment.
c) Provide the results of a calculation (pressure versus time curve) for the largest conceivable local detonation which could occur in your containment. Demonstrate that the effects of such a detonation could be safely accommodated by structures and essential equipment. Also, provide an estimate of the limiting size of a cloud of detonable gas with regard to the structural capability of the containment shell.
Response 5 i
The issues of local detonation and transition to detonation have been addressed in previous submittals. Refer to:
l
- Sequoyah Nuclear Plant Hydrogen Study, Volume II, Revision in Response to NRC Questions (letter from J. L. Cross to R. L. Tedesco dated December 11, 1980).
- Additional Information Requested by NRC (letter from J. L. Cross to R. L. Tedesco dated December 17, 1980).
- Resolution of Equipment Survivability Issue for the Sequoyah Nuclear Plant (letters from L. M. Mills to E. Adensam dated June 2,1981, and June 3, 1981).
- Response to Additional NRC Questions on Hydrogen Control System (letters from L. M. Mills to E. Adensam dated December 1,1981, and January 5, 1982).
- Executive Summary Report (letter from L. M. Mills to E. Adensam dated September 27, 1982).
The reference McGill tests were performed in laboratory-scale apparatus with specialized features such as large length / diameter ratios, uniaxial flame propagation, regularly spaced obstacles, etc., which are designed to promote the detonability of test mixtures. The McGill test conditions would not exist in the Sequoyah containment. Four major areas of difference that have been addressed at length in the referenced submittals include the available i
i I
E72291.51 i
~
hydrogen concentration, the available igniticr. Ocurce strength; the confined geometry with a large length / diameter ratio, and the presence of regular obs tacles. We agree that the possibility of transition to detonation and local detonation is remote and believe that further analysis of the consequences of these events is thus unwarranted.
a) The conditions associated with flame acceleration and detonation in the laboratory have been discussed in relation to the Sequoyah containment in the referenced submittals. The probability of those conditions is judged to be extremely remote. No locations were identified in the containment at which flame acceleration / detonation would occur.
b) Since significant flame acceleration in the containment is so improbable, the resulting pressure increase and loads on structures and equipment would be hypothetical.
c) As stated in previous submittals, we cannot conceive of a local detonation occurring in the Sequoyah containment. However, at the request of the NRC, TVA provided a calculated pressure versus time curve from a hypothetical local detonation in our submittal of December 17, 1980, referenced above. An analysis of the containment shell response to this load was provided in our submittal of June 2,1981, referenced above. This analysis demonstrated that a margin of safety of three existed before material yield would be reached. The effect of a hypothetical local detonation on equipment has not been analyzed.
However, as stated in our submittal of December 11, 1980, referenced above, the effect of such a hypothetical local detonation would be attenuated greatly by distance. It is probable that redundant equipment would have enough physical separation to avoid damage to both trains.
G l
l E72291.01 I
l
Question 6 The analysis provided to date concerning the survivability of air return fans and hydrogen skimmer fans neglects any fan overspeed or motoring which occurs as a result of postulated hydrogen combustion in the upper plenum and upper containment. Describe how the fans will react to the differential pressure associated with hydrogen combustion, and justify the assumptions concerning fan overspeed. Describe the effects of combustion in the lower compartment (e.g., tan stalling).
Response 6 Analyses have been submitted previously addressing the survivability of the air return fans under both pressure and temperature, effects during hydrogen combustion postulated to occur in the upper compartment. No burns were predicted by CL ASIX to occur in the upper co=partment for the bas'e case parameter assumptions. However, some of the sensitivity studies that were performed did result in upper compartment burns. In the analyses done previously to address the pressure effect on the fans, any overspeeding of the fans was neglected for simplicity. This is believed to be a reasonable assumption because the pressure differential during the burns is neither very great or very extended and because the pressure loading condition used in the analysis was so conservative. This pressure load was assumed to be a constant 50 psid force acting downward on the fan blades and was assumed to occur in addition to all the loads the fan experiences during operation at its normal speed. The static load of 50 psid is very conservative since it exceeds even the worst peak transient differential pressures during a burn.
For example, in the sensitivity case where the hydrogen ignition lLnit in the upper co=partment and the dead-ended region was assumed to be 6 volume percent with 60% burn completeness, the duration of an upper compartment burn pressurization was about 12 seconds and the peak differential pressure was about 7.5 psid. The integrated load would only be about 36 psi-seconds. A transient load of this magnitude is not believed to have a potential for causing significant overspeeding of the fan.
A previous submittal has also addressed air return fan survivability during postulated lower compartment burns. During the period of lower compartment combustion and pressurization, the backdraft dampers above the fans would close and prevent significant differential pressure loads on the fans. These dampers were designed to withstand pressurization during a design basis LOCA which would cause a higher differential pressure than calculated in any of the burn sensitivity studies. The air return fans have been operated during a test with the dampers closed and experienced no damage such as from stalling.
E72291.d1
Question 7 With regard to the equipment survivability analysis, the level of conservatism implicit in the temperature forcing function is developed for the lower containment and upper plenum is not apparent and quantifiable. Additional analyses should be conducted to provide a base line or "best estimate" of equipment response, and to ensure that temperature curves assumed in the analyses embody all uncertainties in the accident sequence and combu tion parameters. Accordingly, provide analyses of equipment temperature response to:
- 1) The base case transient assumed in the containment analyses.
- 2) The containment transient resulting,from a spectrum of accident scenarios.
'd-=~""~~
- 3) The containment transients resulting under different assumed values for flame speed and ignition criteria for the worst case accident sequence. The range of these combustion parameters assumed for the equipment survivability anlayses should include but not necessarily be limited to the values assumed in the containment sensitivity studies, ie.,1-12 ft/seo speed and 6-10%
hydrogen for ignition.
Response 7
- 1) In our response of December 1,1981, we provided equipment survivability results for 8 v/o-85% hydrogen burns with a flame speed of 1 ft/sec. At that time we also performed HEATING 5 analyses for a flame speed of'6 ft/sec for all the equipment analyzed in the 1 ft/see submittal. The 1 ft/sec results showed higher equipment temperatures in every instance than the 6 ft/sec analyses. For that reason, we submitted only the 1 f t/sec results.
1 2)
The S D case is a reasonable upper bound scenario for the 2
Sequoyah Plant. The maximum hydrogen release rate and the total amount of hydrogen released prior to core slump, as predicted by MARCH, bounds other accident scenarios believed to be high contributors to risk at Sequoyah. In our December 1,1981, submittal, we provided maximum The S D maximum release rate release rates for several scenarios.
2 was 1.1 lb/sec. An S;D had the highest peak release rate at 1.3 The S D eve:
- oxidized 75% of the core.
The next highest lb/sec.
2 scenario involved approximately 35% of the core. While S D has a j
slightly higher release rate than S D, it is not high enough to 2
result in oxygen inerting during burns, prevent a rapid reduction in hydrogen concentration in the burn compartmeat during a burn, nor produce higher atmospheric and flame temperatures for a given ignition criteria than the S D case.
The much larger total amount of hydrogen 2
released in the S D case results in more burns and thus higher 2
equipment temperatures.
E72293 04
The S D scenario used for the equipment survivability 2
evaluations produces higher equipment temperatures than would be produced by other scenarios reviewed.
The S D results, therefore, 2
conservatively bound the other scenarios.
- 3) As stated in our response to item 1 of this question, flame speeds of 1 f t/sec produced higher temperatures than 6 ft/sec speeds.
The comparison of the cases showed that the longer burn duration seen at the lower speeds input more energy to the equipment and was more important than the change in peak temperature.
Evaluations using flame speeds that are faster than those studied will not, therefore, result in higher equipment temperatures than those previously reported. In our response to question 3 of your October 1, 1982, request for additional information we have provided the results of thermal analyses of equipment for burn criteria of 6 v/o-60% (CLASIX case 1C). The analyses showed the peak equipment temperatures are essentially the same as reported in our previous submittals. There ' arm still large margins between the calculated values and the survivable temperatures.
E72293 04
~, - -
- - - - -., - - -. ~
T l
l Question 8 For the survivability analysis, it is our understanding that the current thermal model assumes radiation from the flame to the object only during a burn, with convection occurring at all times outside the burn period. In an actual burn, radiation from the cloud of hot gases following the flame front can account for a substantial portion of the total heat transfer to the object. An additional heat flux term or a combined radiation-convection heat transfer coefficient should be used to account for this radiant heat source. In this regard, clarify the treatment of heat transfer following the burn and justify the approach l
taken.
)
Response 8 The equipment survivability analysis submitted on December 1, 1981, utilized thermal models which assumed radiative heat transfer only during a burn. The radiative heat transfer during the burn included tha radiation from the cloud of hot gases following the flame front.
Radiative heat transfer from the hot gas cloud for all thermal models was evaluated at the adabatic flame temperature. Additional analyses have shown that radiative heat transfer from the atmosphere to the 1
l equipment after burn termination produced changes in the equipment surface temperature response of about 100F.
The CLASIX temperature profile was used as the temperature forcing function for the radiative heat transfer after the burn was completed. Gas and surface emissivities of 1.0 (i.e., black body) and view factors of 1.0 were used in the post burn period for conservatism.
~
f i
l l
1 f
I i
E72293 04
(
I
Question 9 HEDL containment mixing tests conducted as part of ICOG/EPRI R&D program indicate that spatial hydrogen concaq, ration gradients of as much as 2 to 75 t
can be expected to exist within containment at a given time. If such a gradient were to exist within the v61bme of a hydrogen cloud in which
~
concentration combustion has just been initiated, the volume-average hydrogen for the cloud can conceivably be significantly higher than the hydrogen concentration at the point of ignition. In light of this, discuss the influence of hydrogen concentration gradients on the concentration requirement for ignition that is input to CLASIX, and justify the ignition concentration value used in the CLASIX containment analyses.
Response 9 The results of the Hanford containment mixing test were described'in Appendix A.6 of TVA's Quarterly Report No. 5 and in section IV.E of the technical sum =ary attached to TVA's executive summary report. The maximum spatial hydrogen concentration gradients measured during any of the tests were less than three volume percent with two exceptions. These exceptions occurred during tests HM-1A and HM-2 which revealed test vessel design details which were not prototypic of actual ice condenser containment conditions as discussed in Response 1(d). We believe that the maximum test gradients of less than 3 percent indicate that relatively rapid and uniform mixing would occur during postulated hydrogen release scenarios in the plant. Assuming that gradients of this magnitude (less than 3%) could exist in the plant before ignition, the volume of such a cloud with a higher concentration away from the point of ignition could not be significant due to the number of igniters distributed throughout each region. The sensitivity of containment response to the hydrogen lower ignition limit has been analyzed with CLASIX.
The existence of potential nonuniformities of the magnitude discussed here would not be expected to yield a significantly different response.
E72291.01
Question 10 Describe in detail the fog fonnation study cited in response to Question 9 of the July 21, 1981, Request for Information. Include in this description the analytical development of the models for fog formation and removal, methods 7
for solution, assumptions, and input parameters. Provide plots of fog concentration and size as a function of time assuming various spray removal
{
efficiencies, and mean droplet diameters.
Question 11 P
Describe in detail the analyses of fog effects on hydrogen combustion cited in response to Question 9 of the July 21, 1981, Request for Information.
i Include in this description the analytical development of the combustion l
kinetics and heat transfer models, and quantitative comparisons between the theoretical results and data obtained from the Factory Mutual Tests.
Provide plots of fog droplet size and concentrations required to inert at various hydrogen concentrations under typical post-LOCA containment conditions.
Response 10 and 11 Refer to the attachment, " Fog Inerting Analysis for PWR Ice Condenser Plants," for the information requested in questions 10 and 11.
4
=
I v
i i
l
}
1 l
.I l
E72291.01
~.
l l
l Question 12 1
In the CLASIX spray model it is not clear whether the mass of spray treated j
in a time increment is assumed to be only that amount of spray mass which is introduced in a single time step, or the mass of droplet accumulated in I
the atmosphere over the fall time period. Clarify the spray mass I
accounting used in CLASIX and the mass of spray treated in a single time step. Discuss the significance of any errors introduced by the apparent assumption that only one time increment of spray mass is exposed to the containment atmosphere during a single time step.
1 Msponse 12 The mass of spray treated in a time increment by the CLASIX spray model is the amount of spray introduced in a single time step and not the mass of droplet accumulated in the atmosphere over the fall time. The CLASIX spray model model operates in a different time domain than the compartment. The compartment conditions are frozen in time and the compartment response to the spray is determined as if the mass of spray introduced during the time step completed its fall during the time step. The compartment mass and energy balance is updated at the end of each time step to reflect the spray interaction. The spray interaction is determined by a classical transient technique which is fully described in responses 10 (c,d) and 11 (a,b) in our October 18, 1982, submittal. Based on the discussions provided, we believe the CLASIX spray model provides an appropriate treatment of spray and containment atmospheric behavior for hydrogen burn transients.
O I
E72293.04
l Question 13 l
CLASIX spray model analyses provided to date have been limited to the comparison of pressure, temperature, and integrated heat removal for the purpose of evaluating the effect of the spray operating in a separate time domain. Additional information is needed, however, to confirm the adequacy
)
of the heat and mass transfer relationships and assumptions implicit in the CLASIX spray models, especially in treating a compartment in which hydrogen combustion is taking place. In this regard:
a) Provide a quantitive description of the spray heat and mass transfer under containment conditions typical of a hydrogen burn.
Include in your response plots of containment temperature, spray heat transfer, spray mass evaporation, and suspended water mass as a function of time for both the CLASIX spray model and a model in which the spray mass is tracked throughout the fall (and allowed to accumulate in the containment atmosphere).
b) Provide analyses of spray mass evaporation and pressure suppression effects for an upper compartment burn.
c) Justify the drop film coefficient value assumed in the spray model 4
analyses (20 Btu /h f t20F) and discuss the effect of using a constant value throughout a burn transient.
Response 13 a) The CLASIX Topical Report includes a comparison of the CLASIX spray model to a finite difference spray model for atmospheric temperature 0
over 700 F (see figure D-1).
The temperatures used in this comparison are consistent with the temperatures resulting from an upper compartment hydrogen burn. We believe this figure augmented by our response to questions 10 and 11 of your August 9,1982, request for additional information on CLASIX will adequately address your concerns.
Our response to the August 9,1982, letter was submitted October 18, l
1982.
b) Sensitivity studies of various spray parameters were provided December 15, 1980, in our Sequoyah Nuclear Plant Core Degradation Program Volume II report. Refer to Table 10 of Appendix U for a summary of these studies, c) Refer to CLASIX case JV906 of our December 15, 1980, submittal. In this case the spray heat transfer coefficient was reduced from 20 2
BTU /hr-f t _oF to 2.
For burns in the upper compartment based on an 8 v/o ignition criteria and 50% burn completeness, the temperature in the upper compartment increased 800F due to the heat transfer coefficient reduction. This shows the results are not particularly sensitive to the heat transfer coefficient chosen.
E72293 04 4
1
-..-.- w
---.-. ---.---m-w e
i-
Question 14 Concerning the CLASIX containment response analyses:
a) Justify the burn time and burn propagation delay times used (reported burn times for Sequoyah an* 1cGuire differ by a factor of 2 to 3).
b) Justify the radiant heat transfer beam lengths used (a beam length of 59 ft for the lower compartment in Sequoyah seems high - 20 to 30 ft may be more appropriate).
c)
The base case and majority of S D sensitivity studies assume that 2
combustion occurs at an 85 hydrogen concentration with an 85%
' completeness of burn. Available combustion data for hydrogen / dry air mixtures indicate that lean mixtures of approximately 8% H2 and below are prevented from reacting completely and adiabatically due to buoyancy, diffusion and heat loss effects. Only as hydrogen concentration is increased to about 8.5% will the reaction begin to approach adiabaticity. While arguments for an 85 ignition concentration may be valid, provide the results of additional CLASIX analyses to indicate the effect of an increase in ignition concentration from 8% to 8.5-95.
d) Provide the results of CLASIX analyses for flame speeds of 10 and 100 times the present value, e) To assess the effect of igniter system failure or ineffectiveness, e
provide the results of sensitivity studies in which the lower and dead-ended compartments are effectively inerted, and the upper plenum igniters burn with low efficiency or not at all. Assume combustion in the upper compartment at 9-10% hydrogen.
Response 14 a) Refer to our response to question 4a of your letter dated August 9, 1982. Our response was submitted October 18, 1982.
b) We agree. The beam length value used in all of our analyses provided since mid 1981 was 25 feet for the lower compartment. The value provided in Table 11 of our December 1, 1981, submittal is in error.
c) The purpose of providing results at 6, 8, and 10 v/o was to preclude running a multitude of cases at slightly varied hydrogen concentration values as a criteria for ignition. These runs are believed to be sufficient to evaluate igniter performance. Additionally, Duke Power submitted results for their McGuire plant based on an 8.5 v/o and 100%
burn completeness. We recommend you refen to their results. Their results show there is not a substantial difference between 8 and 8.5 v/o ignition criteria.
d) We believe additional flame speed sen'sitivity analyses are unwarranted.
We provided results for an order of~ magnitude shift in the flame speed.
A two order of magnitude shift in flame speeds for some of the values provided would result in supersonic flames and would not be physically achievable in our plant.
E72293.04
At present, as supported by all transient test data, the pressures seen in vessels with a pre-energized igniter system are well below adiabatic for the 6, 8, or 10 v/o ignition criteris used to analyze Sequoyah. There is no question the faster the rate of energy addition, the closer the pressures will approach the adiabatic pressure for a given hydrogen concentration. In the limit, if the energy addition rate is sufficiently high (i.e., high flame speed), venting through the ice condenser doors will not occur and the pressure in the. burn compartment will behave as a perfectly insulated single volume vessel. The increase in differential pressure that would be obtained in this a
a instance would be agproximately 33 lb/in at 6 v/o, 45 lb/in at 8 v/o, and 60 lb/in at 10 v/o for complete burns.
e) Refer to case JV903 in Appendix U of our December 15, 1980, submittal where the results for the requested case were provided. The case was based on 10 v/o ignition criteria and no air return ran operation. The results show an upper compartment burn producing in a peak pressure of 2
92 lb/in a.
E72293 04
RESPONSE TO REQ' JEST FOR ADDITIONAL INFORMATION 0::
i EQUIPMENT SURVIVABILITY l
+
Question 1 In response to Item 2 in your letter dated April 6,1982, you have provided only one example to indicate that the temperature reached by the equipment during a hydrogen burn is below the qualification temperature for that equipment. Confirm that you have performed analysis for all the equipment required for the hydrogen burn and provide the qualification testing of these equipment. Also provide the reference to individual Summary Component Evaluation Worksheets (SCEWS) which were submitted in the EQ submittal in response to NUREG-0588, so that the staff can make an j
independent evaluation of the subject analyses.
Response 1 In our submittals on equipment survivability dated June 2, 1981, December 1,1981, and April 6,1982, TVA provided the results of testing or analysis of five pieces of equipment for hydrogen burns. Detailed evaluations were not provided for all components on the equipment list provided in our earlier submittals. Justification of our approach in evaluting only selected items was also proviced in our December 1, 196i, and April 6,1982, submittals.
Qualification testing" for hydrogen burns was not performed nor is it required.
The following list provides the requested reference to the SCEWS prov$ded in our Electrical Equipment Environmental Qualification Report in accordance with NUREG-0588 for unit 1 at Sequoyah. The ite=s listed below are included in Table 3.11-4 with the page number for easy reference. The equipment list is taken from Table 2.2-1 of our December 1, 1981, submittal.
Item P_ age, LT-2-148, -156, -164, -171, -172 -173, -174, 175 7
Air Return Fans 8
FCV-43-201, -202, -207, -208 22 LT-63-176, -177, -178, -179 17 FCV-63-172 12 LT-68-320, -355A 14 TE-68-1, -24, -43, -65 13 TE-68-18, -41, -60, -83 13 Electrical Per.etrations 10 Containment Isolation Valves 1.2,3,5,6,11,12,18, 1c,22,23,26,27,28,29 E72293.04
--n-.
. -.,. ~......, -
n.
- - - ~. - - - - -
ENCLOSURE 2 RESPONSE TO OCTOBER 1, 1982 LETTER FROM E. ADENSAM TO H. G. PARRIS REQUESTING ADDITIONAL INFORMATION ON EQUIPMENT SURVIVABILITY SEQUOYAH NUCLEAR PLANT
i l
l The hydrogen igniters for the Interim Distributed Ignition System (IDIS) and the Permanent Hydrogen Mitigation System (PHMS) are not Class 1E and are thus not included. The ice condenser doors and seals, flanged penetrations, equipment hatch, and air locks are not Class 1E components and thus do not have SCEWs. The hydrogen analyzers are listed in Table 2.2-1 but are located outside containment and are thus not subjected to hydrogen burns. The core exit thermocouples are not Class 1E equipment.
The reactor vessel level thermocouples and the vessel vent valves have not been added to the plant at this time. When they are, the NUREG-0588 report will be updated to include these components.
Question 3 In your response to item 3 in your letter dated April 6,1982, you indicated that for Case 1C the burns are of a much shorter duration and the ambient te=perature is lower. The staff recognizes that the burns are of a shorter duration, but~1n addition to this duration between burns is also of r
much shorter duration which allows less time for the equipment to cooldown. Also, if the licensee wants to denonstrate the blowdown sensitivity studies (case JJ1) that containment integrity is maintained even for three times the mass flow rate used in S D scenario then it 2
should also be demonstrated that equipment will survive for that scenario.
Hence, provide the equipment temperature for these two cases.
kesponse3 The results of the thermal anlaysis of the cable in conduit for a burn i
criteria of 6 v/o-605 (CLASIX Case 10) is provided on Figure 1.
The response of the cable in conduit is provided as it is the most responsive to environmental changes of any of the equipment analyzed. The analysis 4
shows that the maximum surface temperature is essentially the sa:e as shown for the same 8 v/o-85% case on Figure 2-2.14 of our December 1,
- 1981, l
submittal. This analysis of CLASIX Case 1C very conservatively includes radiative heat transfer from the hot gas cloud during the burn at the i
adiabatic flame temperature and radiative heat transfer based on the CLASIX l
profile at all times during the transient. This essentially doubles the aadiation heat transfer during the burn. In addition, to adding more conservatism the radiation term utilizing the CLASIX profile used gas and equipment surface emissivities of 1.0 (i.e., black body radiation) and view factors of 1.0.
Natural convection was also included in the sa:e manner as presented in the analysis discussed in our December 1, 1981, submittal..
Even with these gross conservati_.s the same large margins in our earlier analyses still remain assuring the survivability of our equipment.
The S D scenario used for equipment survivability analysis utilized a 2
maximum hydrogen release rate of 1.1 lb/ min. As can be seen by our response to Item 2 of Question 7 and from the table on scenarios in section 1981, submittal, the S D release rate is most C of our December 1, 2
appropriate for all plant transients. We provided a discussion of why equipment analysis for CLASIX Case JJ1 is not required in our April 6, 1982, submittal. The containment transients based on the S D release 2
rates provide a conservative environmental profile for equip =ent survivability analysis.
i l
E72293 04 J
e 1
i Question 4 In your submittal of December 1, 1981, you indicated that the analysis of the teflon wire which was melted during Fenwal testing also indicated that teflon will completely melt in 1.4 seconds. Provide the melting point for the teflon used in the analysis. Also using the same model provide the results of the analyses predicting the surface temperature of the exposed thermocouple and RTD cable.
Response 4 The melting point of teflon used to determine if the insulation on the thermocouple wire in our analysis was 6170F.
This value was obtained from the Omega Temperature Measurement Handbook, 1982 edition. The calculated insulation surface temperature in our analysis was 9900F.
Analyses of the RTD and thermocouple cable were not performed. Testing was done in lieu of analysis. Because of the te=peratures reached during the a
tests (13680F for the thermocouple cable) the tests were adequate representations of hydrogen burns in the lower compartment where this cabling is located. Analyses would not provide additional information and were therefore not performed. Additional justifications are provided in our December 1, 1981, submittal.
l E72293 04 I
l I
l
Question 2 Since the probability of local detonation exists, provide the analyses or experimental results to demonstrate the survivability of essential equipment for the local detonation predicted.
Response 2 Refer to response 5 of Enclosure 1, " Response to Request for Additional Information on Hydrogen Control for Ice Condenser Plants" for a discussion of local detonation and equipment survivability.
_. _ = -. - - -
Question 5 2
Sand 5,basedontheexperimentalresults,ispredictingthatscalingmay have !a big icpact on the analytical model used to predict equipment d
te=perature. Tests results performed in small chamber cay r.ct be used to demonstrate the equipment survivability in the contianment. Based on this, j
demonstrate how the analytical model used for Sequoyah takes into account t
the scaling factor. If the analytical model does not consider the scaling factor, provide the basis for eliminating this factor.
+
Response 5 We agree with Sandia that scaling effects must be carefully considered in not only small tests but any tests that do not accurately =odel the plant.
Because of this, all the analyses performed for Sequoyah were based on full 1
scale. No small scale test data was used which would require extrapolation up to plant conditions. All scale factors for the CLASIX and HEATING S analyses are therefore 1.0.
i I
i i
i l
1 i
i I
l 4
E72293.04 i
1
FIGURE 1 SQN H2 STUDIES o6 4
SQCC6L1 CABLE IN CONDUIT o
N-CONDUIT SURFACE l
INSULATOR - - - - -
M COPPER CABLE 6
CiP o
K%
\\
I s-p m
ma.
D m
,t ',>,
~
w y-
~,
w
(" 'N 8' '%, ' 's'
'*s.h 0
J
,,y e
xe
,J
=-
,,~~
w me H 8~
.j l 'J
~
a '~1
,,,, ~
,~, )
g
/'sl
. i g'
l
,~~
i g~'%I O
e n-._{
~! s
% gl 9'
t 8
i i
0.0 200.0 100.0 600.0 000.0 1000.0 1200.0 1400.0 1600.0 1800.0 2000.0 2200.0 TIME (SEC.)
ATTACHMENT i
F03 INERTING ANALYSIS i
I FOR PWR ICE CONDENSER PLANTS l
i l
1 i
i I
I CORE AND CONTAIN!ENT ANALYSIS NUCLEAR SAFETY DEPARTENT WESTINGHOUSE ELECTRIC CORP, I
I I
i i
=
9 4
0 OCTOBER 1982
(
0430Q:1/101882
_.g_
m_, -
,y_,
-r_..
7 7
-_m--
_p.-._
ABSTRACT 1
l The recent hydrogen burn test conducted at the Lawrence Livemore j
j National Laboratory has raised the NRC and the ice condenser plant owners concern about fog inerting probability and consequences in ice condenser plants. The present investigation i s aimed at resolving this
{
fog inerting issue.
In this report, major fog fomation and removal l
mechanisms that could exist in the post-accident ice condenser contain-i}
ment are identified and quantified. Methodologies have been developed 1
i for predicting fog fomation and removal rates and for predicting fog l
concentrations in various compartments in an ice condenser containment.
This methodology employs the Hijikata-Mori boundary layer fog fomation theory, and calculates the fog fomation rates due to boundary layer and l
bulk stream condensation. Next, the mass conservation equations for fog J
droplets are solved and the fog concentrations in various compartments are calculated. The methodology has been used to predict fog concentra-tions in the Sequoyah, McGuire, and D. C. Cook containments, using the CLASIX output data for an S D accident sequence.
2 In order to utilize the calculational results from the study, a fog inerting criterion has been established. This criterion uses the hydro-i gen concentration, volume mean drop size, and fog concentration to define the fog inerting regime. For a given hydrogen concentration, the minimum fog inerting concentration (in mass / volume) was found to vary with the square of the volune mean drop diameter. Thi s criterion has been verified by the recent Factory Mutual fog inerting test data.
The application of the fog inerting criterion to the three ice condenser plants shows that fog inerting would not exist in the upper and lower compartments.
Some slight elevation of the lower flammability limit in the ice condenser upper plenum may be possible due to the presence of fog but the present calculations show that hydrogen concentrations of 8-8,5 pen:ent in the upper plenum are still flamable. Previous CLASIX analyses have shown that the containment response to burning 8-8,5 percent hydrogen mixtures would be acceptable.
I 04300:1/101982
l ABSTRACT i
l q
The recent hydrogen burn test conducted at the Lawrence Livermore j
National Laboratory has raised the NRC and the ice condenser plant owners concern about fog inerting probability and consequences in ice condenser plants. The present investigation is aimed at resolving this fog inerting issue. In this report, major fog fomation and removal mechanisms that could exist in the post-accident ice condenser contain-ment are identified and quantified. Methodologies have been developed for predicting fog fonnation and removal rates and for predicting fog concentrations in various compartments in an ice condenser containment.
This methodolcgy employs the Hijikata-Mori boundary layer fog fomation
[
theon, and calculates the fog fonnation rates due to boundary 1 Ayer and bulk stream condensation.
Next, the mass conservation equations for fog droplets a-e solved and the fog concentrations in various compartments are calculated. The methodology has been used to predict fog concentra-tions in the Sequoyah, McGuire, and D. C. Cook containments, using the l
CLASIX output data for an S D accident sequence.
2 i
i In order to utilize the calculational results from the study, a fog inerting criterion has been established. This criterion uses the hydro-i gen concentration, volse mean drop size, and fog concentration to define the fog inerting regime. For a given hydrogen concentration, the minimun fog inerting concentration (in mass /volune) was found to vary with the square of the volune mean drop diameter. This criterion has been verified by the recent Factory Mutual fog inerting test data.
The applicat on of the fog inerting criterion to the three ice condenser l
plants shows that fog inerting would not exist in the upper and lower compartments. Some slight elevation of the lower flammability limit in the ice condenser upper plenum may be possible due to the presence of fog but the present calculations show that hydrogen concentrations of 8-8.5 pen:ent in the upper plenum are still flaanable. Previous CLASIX analyses have shown that the containment response to burning 8-8,5 percent hydrogen mixtures would be acceptable.
I 0430Q:1/101982
TABLE OF CONTENTS t
Section Title Page ABSTRACT i
l TABLE OF CONTENTS 11 LIST OF TABLES iv LIST OF FIGURES v
1.0 BACKGROUND
1-1
2.0 INTRODUCTION
2-1 3.0 FOG GENERATING E CHANISMS 3-1 IN AN ICE CONDENSER CONTAINENT 3.1 Fog Generated by Break Flow 3-1 3.1.1 Amount of Fog Generated 3-3 by Break Flow 3.1.2 Drop Sizes Generated by Break Flow 3-5
,j 3.2 Nucleation of Fog Droplets in Containment 3-6 I
Atmosphere 3.2.1 Nucleation Theories 3-7 3.2.1.T Clas~sTcHTTheory of 3-7 Homogeneous Nucleation 3.2.1.2 Heterogeneous Nucleation 3-9 f
Theory 3.2.2 Fog Fomation Conditions 3-10 3.2.3 Conditions for Fog Fonnation Near 3-12 a Cold Surface 3.2.4 Rate of Fog Formation 3-15 3.2.5 Fog Drop Sizes 3-19 3.3 Fine Mist Droplets From Containment Sprays 3-19 4.0 FOG REMOVAL ECHANISMS IN AN ICE CONDENSER 4-1 CONTAI!4ENT 4.1 Settling Due to Gravity 4-1 4.2 Agglomeration 4-2 4.3 Vapori zation 4-2 4.4 Removal by Spray Drops 4-3 4.5 Other Removal Mghant sms 4-3 II 0430Q:1/101882 w-
l TABLE OF CONTENTS (Continued)
Section Title Page 5.0 FOG INERTING CRITERIA 5-1 5.1 Previous Work 5-1 5.2 Present Theory 5-2 5.3 Verification of Theories by Experiments 5-6
~
6.0 ASSESSENT OF FOG IERTING PROBABILITY IN ICE 6-1 CONDENSER CONTAINENTS 6.1 Detennination of Voltane Fraction of Fog 6-1 Droplets in Ice Condenser Containment f
Subcompartments 6.1.1 Calculation of mbreak 6-5 6.1.2 Calculation of m 6-6 cond 6.1.3 Calculation of m 6-6 set l
6.1.4 Calculation of m 6-7 sp 6.2 Fog Inerting Probability in the Sequoyah 6-7 Plant 6.3 Fog Inerting Probability 'iIt the McGuire 6-22 Plant 6.4 Fog Inerting Probability in the D. C. Cook 6-35 Plant j
7.0 SUMt%RY AND CONCLUSIONS 7-1 ACXNOWLEDGENTS 7-3 REFERENCES R-1 APPENDIX A A-1 APPENDIX 3 B-1 111 04300:1/101982 e-1 4
t-p-
m __ _
LIST OF TABLES Table No.
Title Page I'
6.1 Input Data for Sequoyah Lower Compartment 6-17 6.2 Input Data for Sequoyah Ice Condenser 6-18 t
6.3 Geometric Data for Sequoyah Containment 6-19 6.4 MARCH Prediction of Reactor Coolant Mass and 6-20 Energy Release Rate for the S D Sequence 2
3 6.5 Intercompartmental Flow Rates (ft /sec) 6-21 Predicted by CLASIX for Sequoyah i
j 6.6 Input Data for McGuire Lower Compartment 6-31 6.7 Input Data for McGuire Ice Condenser 6-32 i
6.8 Geometric Data for McGuire Contairnent 6-33 i
1 3
6.9 Inten:ompartmental F, low Rates (f t /sec) 6-34 Predicted by CLASIX for McGuire i
a j
6.10 Input Data for D. C. Cook Lower Compartment 6-44 6.11 Input Data for D. C. Cook Ice Condenser 6-45 6.12 Geometric Data for D. C. Cook Containment 6-46 3
6.13 Intenompartmental Flow Rates (ft /sec) 6-47 Predicted cy CLASIX for D. C. Cook iv 04300:1/101982
-T
LIST OF FIGURES Figure No.
Title Page
}
3.1 T-S Diagre for Reactor Coolant Discharged 3-4 From Break 3.2 Vapor Pressure and Temperature Profile Near 3-14 a Cold Surface 3.3 Formation of Fog Near a Cold Surf ace 3-16 3.4 Drop Size Distribution Predicted by Neiburger 3-20 and Chien l
l 3.5 Particle Size Distribution for 50 PSI Pressure 3-21 Drop Across Nozzle No.1713 l
1 4.1 Teminal Velocity as a Function of Drop Radius 4-5 in Steam-Air At:nospheres 4.2 Agglomeration Rates in Air Between Equal-Sized 4-5 Drops J
5.1 Minimun Ignition Energies and Quenching Distance 5-3 for Hydrogen-Oxygen Inert Gas Mixtures at Atmo-spheric Pressure 5.2 The Effect of Droplet Spacing on Flee Quenching 5-4 5.3 Schematic Representation of Temperature Profile 5-7 Through the Flme Front The Parmeter 8 a as a Function of 5-7 5.4 9
(Y
- Y )/ ej for Different Values of Kej f
u l
v 04300:1/101882 9
h LIST OF FIGUIES (Continued)
Figure No.
Title Page I
5.5 (K)cri t 5-8 1 at the Flammability Limit as a 6
Function of (Yu ~ Y l/81 f
5.6 Comparison Between Theories and Factor / Mutual 5-10 Fog Inerting Experiments on 4.76 Percent H2 5.7 Comparison Between the Present Theory and 5-11 Factory Mutual Fog Inerting Experiments on 7.2 Percent H2 5.8 Comparison Between the Present Theory and 5-12 Factory Mutual Fog !nerting Experiments on 7.9 Percent H2 6.1 Sequoyah CLASIX Containnent Model 6-8 6.2 Fog Fomation in TVA EquoyahTowe'r Compartment-6-10 6.I' Fog Fcmation in TVA Sequoyah Ice Condenser 6-11 l
1 6-14 6.4 Fog Concentration in Sequoyah Containment 1
6.5 McGuire CLASIX Containment Model 6-23 6-24 6.6 Fog Fomation in Duke McGuire Lower Compart:nent 1
6.7 Fog Fomation in Duke McGuire Ice Condenser 6-25 6-28 6.8 Fog Concentration in McGuire Containment 6.9 D. C. Cook CLASIX Containment Model 6-36 vi 0430Q:1/101982
LIST OF FIGullES (Continued)
Figure No.
Title Page Fog Formation in AEP Cook Lower Compartment 6-37 6.10 6.11 Fog Fonsation in AEP Cook Ice Condenser 6-38 6.12 Fog Concentration in D.C. Cook Containment 6-41 t
i I
l 1
t i
vii 04300:1/101982
1.0 BACXGROUND The incident at Three Mile Island has demonstrated that a significant amount of hydrogen could be generated during core degradation. Thi s experience raised NRC concern about the safety of nuclear power plants, in terms of their capability to control hydrogen during severe acci-dents. Since ice condenser plants have a relatively small voltane and low containment design pressure, the NRC has requested the ice condenser plant owners to study hydrogen control methods for use in their plants.
In this regard, the Tennessee Valley Authority (TVA), Duke Power and American Electric Power (AEP) have installed glow plug igniters at various locations inside their ice condenser containments to ignite hydrogen at low concentration.
i Recently, the NRC requested Lawrence Livermore National Laboratory j
l (LLNL) to carry out experiments on these igniters to determine their j
effecti veness.
In these experiments, two tests with high steam concen-tration failed to achieve ignition even after enough steam condensed to yield a theoretically combustible mixture. One explanatory hypothesis was that substantial fog formation could occur when saturated steam is discharged into a unheated vessel and under some conditions-og could effectively preclude hydrogen from combustionIII.
The LLNL tests raised some doubts about the effectiveness of glow plug igniters under fog formation conditions.
In a recent review of hydrogen related issues for ice condenser plants,(2) the NRC has raised several questions concerning the probability and consequences of fog fomation and steam supersaturation in ice condenser plants.
TVA, AEP, and Duke established experimental and theoretical analysis programs to study the effects of fog and spray on igniter perfomance.
The experimental pmgram was contracted to Factory Mutual. The experi-ments were designed to test the glow plug igniter's perfomance under different fogging conditions. In response to the NRC questions, the plant owners requested Westinghouse to perfom fog inerting analyses for the Sequoyah, McGu' ire, and O. C. Cook plants. Thi s report presents the results of the Westinghouse studies.
1-1 04300:1/101882
A m
^&-'A
2.0 INTRODUCTION
From the post-test analysis of the LLNL %drogen burn tests, it appears that substantial fog fomation could have occurred inside the test ves-sel. Generally, fog droplets are only a few microns in diameter. These sizes of droplets have the potential to prevent a flamnable gas mixture from combustion or quench a propagating flane. This is because these si::es of droplets vaporize very fast (on the order of milliseconds),
absorbing an enomous amount of the heat released from combustion if a substantial quantity of these droplets is present in the atmosphere.
In comparison, large water droplets in the range of few hundred microns or larger (e.g. spray droplets) have no inerting effect on combustion (20) i and hence have insignificant effect on glow plug igniter's perfomance.
Therefore, the present analysis will be concentrated on the generation and removal of fog (mist), and its impact on the glow plug igniter sy stem.
There are a number of potential fog generation and removal mechanisms present in a post-accident ice condenser containment atmosphere. The 4
fog generation mechanisms include fog generated by the break flow (if it is two-phase), fog fomation near the ice and structural heat sink sur-f aces (since the surface temperatures could be well below the dew point), and fog generation due to homogeneous and heterogeneous nuclea-tion in condensing bulk streams. The fog removal mechanisms include gravitational settling, agglomeration, vaporization and removal by spray i
i droplets.
In order to estimate the post-accident fog concentrations in ice condenser containments, these competing mechanisms must be studied, i
and evaluated. To solve this problem, it requires a nunerical integra-tion of the mass conservation equations for the mist droplets in the various contaimnent subcompartments. By making some simplifying assunp-i tions, the transient fog concentration in the various subcompart:nents has been estimated.
The analysis presented here considers all the fog removal and generation l
mechanisms previously described except agglomeration.
In addition, it j
04300: 1/101982 2-1
i l
_._.m f
considers the fog entrainment in the intercompartmental flows (including fan flows) in the fog mass conservation equations. CLASIX results for an S 0 event were used as boundary conditions to the problem.
2 In addition to calculation of fog concentrations in various containment compartments, it was necessary to establish a fog inertirg criterion. A fog inerting criterion has been proposed by Berman et al., which pre-dicts the minimum fog concentration required to inert a given hydrogen 5
concentration and given volume mean fog drop size. This criterion seems 4
i to overpredict the minimum fog inerting concentration, when compared with experimental data. A more realistic fog inerting theory is presented in the present study.
The fog inerting methodology, analysis, and results are presented in the following sections of this report. Sections 3 and 4 present the method-ology for calculating the fog formation and removal rates. Section 5 ll gives the fog inerting criteria, and Section 6 presents the results.
l
.l I
5 4
5 1
0430Q:1/101982 2-2
I t
1 3.0 FOG GENERATING tECHANISMS
}
IN AN ICE CONDENSER CONTAINENT The inerting capability of fog droplets depends on their sizes and con-I centration in the contaimnent atmosphere, as well as the hydrogen con-centration. This section is intended to identify various fog generation mechanisms present in an ice condenser contairunent and to detennine the drop sizes and the rates of fog generation from these mechanisms. Three fog generation mechanisms are discussed in this section and the dominant fog generation mechanisms are identified.
3.1 FOG GENERATED BY BREAK FLOW The post-LOCA containment atmosphere is most likely to be a drop-laden atmosphere. The large-scale simulated LOCA experiments conducted to date have directly or indirectly confinned the presence of two-phase I
atmospheres. For example, Marvikken(3) and Battelle - FrankfurtI4) experiments were instrunented to measure fluid densities and water levels in various parts of the containment. Therefore, fog generation by the break flow cannot be neglected. The following discussion of this phenomenon pertains to small LOCAs.
In the early stage of a small LOCA transient, a substantial portion of the primary coolant discharged from the break will remain as liquid.
Because of the superheat and high velocity, this liquid will be framen-ted by aerodynamic forces and homogeneous nucleation mechanisms into small droplets. These droplets are expected to be entrained by the intercompartmental and fan flows and spread to other parts of the ice condenser containment. During their travel throughout the containment, the fog droplets will be removed by gravitational settling, sprays, and vapori zation. The fog generation period lasts until the water level in the reactor vessel falls to the break elevation and the break flow is no For the particular S D sequence analyzed by f%RCH longer two-phase.
2 and previously used as the basis for the perfonnance of a containment 3-1 0430Q: 1/101882
h
--1 m-Q analysis by CLASIX,(5) this period lasts for about 36 minutes and about 4.2 x 105 lbs of water has been discharged into the lower compertment during this period of time.
.l After the water level in the reactor vessel f alls below the break eleva-tion, the break flow rate is substantially reduced. The flow is essen-tially stean and no fog droplets will be generated. As a result, the j
lower compartment becomes superheated afterward. Fog droplets may vaporize during their travel through this compartment and substantial removal of mist droplets is expected.
Large suspended drops generated by the break flow will be removed very quickly by gravitational settling and impingement. For the drops larger than 20 u, the removal rate is high and complete remaval only takes a few seconds. For the smallest drops (less than 1 u) the terminal veloc-ity is so small that they virtually remain suspended in the atmosphere i ndefi nitely. The only effective removal mechanisms for these sizes of drops are vaporization, and collision with larger spre drops. The weight fraction of these sizes of drops is estimated to be below 1 percent (13) of the total drop population. The population of these
!j small drops can increase if nucleaYion oTe~mEryos occurs in a saturated atmosphere.
t 9
O 2
04300:1/101882
3.1.1 AMOUNT OF FOG GENERATED BY BREAK FLOW As discussed previously, the existence of a two-phase drop-laden regime has been observed experimentally. In a small LOCA, flashing of primary coolant at the break and subsequent vaporization of blowdown liquid represent a series of changes of thermodynmic states.
Si nce the reac-tor coolant pressure is high, the break flow will be choked. The accel-eration of primary coolant to the break location is essentially an isen-tropic process, in which the pressure decreases to the po'nt at which substantial homogeneous nucleation occurs. When the flow leaves the break, the liquid is fragmented by both the aerodynamic forces and the nucleation mechanism into small fog droplets. These fog droplets con-i tinue to vaporize, because of the superheat in the droplets, until a thermodynamic equilibrium state is reached. Because of the high super-heat and large aerodynamic forces, it is expected that the fog droplets I
generated are very small.I0I This vaporization process is essentially isenthalpic.
The exi stence of a two phase dmp-laden regime can also be explained by use of a T-S diagram for steam as shown in Figure 3.1 (Figure 1 of Reference 6).
It_is_shown in thi ffigure-thTit-'the blowdown-liquid goes j
through a series of thennodynamic states, starting from the subcooled liquid state B. The liquid expands isentropically from the subcooled o
t state B to the stat'e B1 at the break, where a two-phase critical o
flow is developed. At the see time, temperature changes from T to o
{
T.
After leaving the break, the droplets continue to vaporize 1
because of excessive superheat until finally an equilibrium state B2 is reached at which the droplets are in thennal equilibrium with their surroundi ngs. This vaporization process i s essentially isenthalpic. At this time, the droplet temperature drops to T2 and the atmospheric temperature also rises to T. For a small LOCA, the equilibrium tem-2 perature varies with time. According to the CLASIX analysis of the I
Sequoyah plant, the lower compartment gas temperature rises quickly from 100*F to approximately 200*F and then stays at this temperature for an i
extended period of time. Using these temperatures as final equilibrium l
3-3 04300:1/101882 i
... ~,. _ _,
_.-7,.
.)
g 100 10 1
0.1 0.01 I
I I
I i
'1 450 400 l
I 400 39, i
y A
350 l
b 300 y
ik 250 l
g, 2m f,\\
f;g\\'s 1d/'\\. \\ \\ \\ xN f
9 y xs 71 10, 3..s sx i
ee i
s i s
\\/
\\
\\
\\N s
i 0
0.0 0.2 0.4 0.6 0.8 X-1 P
FIGURE 3.1 T-S DIAGRAM FOR REACTOR COOLANT DISCllARGED FROM BREAK y
?
l
temperatures for water droplets, the weight fraction of water droplets in the break flow is approximately 50 percent, which is consistent with the MARCH calculations (7) of the break flow rate and its energy j
release rate.
The discussion given above is valid only when the initial state of the break flow is subcooled or saturated liquid. After the water level inside the reactor vessel falls below the break elevation, the break flow will be steam. The moisture content of the steam will be very low, even though isentropic expansion mAy lead to homogeneous nucleation and subsequent condensation in the vapor stream. Depending on the super-saturation that can be achieved in this isentropic expansion, a conden-sation shock is possible when critical supersaturation is reached.
However, it is believed that the amount of fog droplets generated by homogeneous nucleation in this supersonic jet is negligible as compared to other fog generating mechanisms. Hence, it will be neglected in thi s present analysis. Therefore, the fog generation by the break flow is considered possible only when the water level in t.he reactor vessel is above the break elevation.
According to the MARCHI7) calculatton at "2t77 sw:onds into the acci-dent, the water level inside the reactor vessel falls below the break elevation for the S 0 case analyzed in Reference 7.
By thi s time 2
approximately 421,000 lbs of water has been discharged from the break.
i It is calculated from MARCH break flow energy and mass output that 56 percent of this discharged fluid, f.e., 236,000 lbs, will be discharged as liquid droplets. However, most of these droplets will be quickly removed by gravitational settling and impinging on the structures and floor.
3.1.2 DROP SIZES GENERATED BY BiEAK FLOW IOI The flashing jet experiment conducted by Brown and York has indi-cated that the drop sizes produced by flashing liquid are small. They derived a correlation for the linear mean drop size based on the test data. The correlation shows that the mean drop size is inversely pro-portional to the Weber number and it decreases linearly with increasing 0430Q:1/101882 3-5
.,-r-_
__w
superheat. However, this correlation is applicable for liquid superheat less than 75'F and it can not be extrapolated to the large superheat of I
the reactor coolant. However, some corclusion concerning the drop sizes j
produced by blowdown of the reactor coolant can be drawn for this condi-tion. The break flow has much 1arger superheat and Weber number than those used in this experiment; therefore, the drop sizes produced by the
.j break flow should be much smaller than -50u observed in this experi-I ment.
Gido and KoestelI9) have developed a method for estimating the drop size leaving the fragmentation / evaporation zone of a blowdown jet. Thi s model is based on the asstanption that drops with an internal temperature difference of less than 5*K will escape fragmentation. This model has been verified by the low superheat data of Brown and York. Application of this method to the LOCA condition shows that the maximum attainable drop size is 7u (this means that any drop size larger than 7a will not esc ~pe fragmentation by homogeneous nucleation). The corresponding mean drop size is about 4, based on the observation of the largest drop size 9
and mean drop size in the experiment reported in Reference 8.
Since the droplets are generated by the break flow before 2172 seconds, most of l
these droplets will be removed by containment sprays before hydrogen l
starts to release into containment (- 3800 seconds). At thi s time, j
most of suspended droplets are fonned by condensation. Therefore, thi s volume mean drop size of 49 is not used in the present analysis; instead, the present analysis uses 10u volume mean drop diameter, which is the nominal drop size for cloud and fog drops formed by condensation..
3.2 NUCLEATION OF FOG DROPLETS IN CONTAINENT ATMOSPHERE Nucleation of water embryos from the homogeneous vapor phase plays an important role in fog generation in containment. Nucleation is a process by which tirly water embryos or condensation nuclei are forned from a pure vapor phase at a rapid rate.
In incipient homogeneous nucleation, the local gas temperature crops below the dew point corres-ponding to the local steam partial pressure and some degree of local supersaturation is needed. The degree of supersaturation needed to 0430Q:1/101982 3-6
f start nucleation depends on the nLaaber of condensation nuclei present in the containment. These condensation nuclei cculd be very small water j
droplets or dust particles. If sufficient number of condensation nuclei i
exist, the required supersaturation could be small.
This section is devoted to the discussion of fog formation by homogene-ous and heterogeneous nucleation. The classical nucleation theories are used to explain the nucleation phenomenon.
3 3.2.1 NUCLEATION THEORIES The process of nucleation of an embryo water drop is important in under-standing the mechanism of fog fomation in ice condenser plants. Two i
types of nucleation process, namely, homogeneous and heterogeneous nucleations, and their theories will be discussed in Section 3.2.1.
3.2.1.1 CLASSICAL THEORY OF HOMOGENEOUS NUCLEATION When an embryo droplet, usually assumed spherical, is fomed from con-densation of water vapor molecules, its free energy changes. The change of free energy can be expressed ah AG = 4wr2 o - (4/3) wr3 g KT in (P/P )
(3.1) n o
where a is the surface free energy per unit area, or surface tension, r l
is the drop radius, P is the vapor pressure, P is the saturation o
}
pressure at the droplet temperature, nt is number of molecules per unit voltme, K is the Boltzman constant, and T is the drop temperature.
The supersaturation S, is defined as P/P.
g Equation (3.1) represents a free energy barrier to the growth of the drops at a given supersaturation. At maximta AG, the critical radius r*
can be obtained from Equation 3.1 as I
h 4
i 34 04300:1/101882 i
^
The drops of the critical size can be considered as condensation nuclei 1
since at this size the drops will grow with no change in free energy.
l This critical size represents an equilibrium size at which a supersatu-rated vapor at vapor pressure P is in equilibrium with this critical drop at a lower saturation pressure P. However, this equilibrium o
mode is unstable. For example, if a drop of the critical size origi-j nally in equilibrium with the surmunding vapor suffers a sudden small increase in size due to condensation, then (if the drop temperature does f
not change), Equation 3.2 shows that the equilibrium pressure, P, or its l
surf ace will decrease. Therefore, the actual vapor pressure will then be greater than the equilibrita value and further condensation will occur. This is wh the drop of.this critical size is called condensa-tion nucleus, n
l The nucleation rate of critical-sized embryos can be obtained from the kinetics of a nonequilibrium distribution of embryos. The classical nucleation theory (10) shows that there is a very sudden increase in
'l the nucleation rate when past a certain critical value of supersatura-i tion. An extensive validation of the nucleation theory was conducted by Volmer and FloodIll) in an e$periment in which a number of vapors were expanded to visible condensation in a cylinder'. The observdd critical
~
supersaturations agreed suprisingly well with theory in nearly all cases, including water vapor.
i Critical condensation nuclei sizes typically range from 10 to 100 atoms. These sizes are considerably smaller than the mean free path of the vapor molecules and therefore the rates of mass and heat transfer at the drop surface cannot bJ predicted by bulk transport theories.
In this case, the kinetic theory of gas should be used to predict the rates of mass and heat transfer at the drop surface.
Starting from the kinetic theory of gas and the energy conservation equation, the rate of growth of a condensation nucleus was obtained by Hill et al.(10)
It was found that the growth rate is on the order of 10-3 ft/sec. Therefore, it takes only about 1 millisecond for the condensation nucleus to grow to a fog droplet size of 1 u.
~
04300:1/101882
_,, -. - + - - -. -
,-.m.,.
,y
J m.
A m
~-
-A 3.2.1.2 HETEROGENEOUS NUCl.EATION THEORY Another mechanism of forming embryos is heterogeneous nucleation on foreign particles that could suspend in the contairnent atmosphere.
l These particles may serve as nucleation sites for vapor and thus enhance the nucleation rate. Th'e source of foreign particles in the containment following core degradation could come from fission product aerosols and dust particles. The size distribution of these particles are important because the supersaturation required to form embryos depends on particle i
l si zes.
A typical size distribution of atmospheric aerosols is that of J unge(12), taken from surveys made near Frankfurt A.M., Germany. The 1
surveys found that the size range of dust particles is from 0.01 to 1 a.
In the range from 0.01 to 0.5 u, there are between 100 and 10,000 particles per cubic centimeter. A majority of particles have sizes smaller than 1 micron. At the smallest size of 0.01 a, the critical 1
supersaturation is about 1.02 and at the largest size the supersatura-tion i s only 1.001.
1 I
The atmospheric aerosols consist of particulates of various-sizes, vari-i ous chemical components, and various electrostatic charges. The aerosol particulates could be soluble or insoluble in water. All these proper-ties could affect the required supersaturation for nucleation.
In the case of insoluble particulates, the contact angle, d, between the embryo and the particle surface is important.
If the particle is com-i pletely wettable, d = 0, it forms a base on which a small amount of water can form a drop of large radius of curvature and thus satisfy the Helmholtz equation (Eq. 3.2) at a much lower supersaturation than would be the case if same number of molecules form a drop with a particle Fletcher (15) developed a relationship between the supersatura-core.
tion and drop radius for several values of contact angle, assuming that the particle is spherical. Competely wettable, a particle of 1 micron or so, when covered with a film of water, i s theoretically at the crit-ical radius, and it needs only 1.001 critical supersaturation.
3-9 0430Q: 1/101882 sr
-m
,,,.---.,n e
-e-
,,,,,,-w-
---w
-s
1 The other soun:e of aerosol particulates is fission products. Duri ng j
nomal operation, the primary coolant contains very little fission
]{
products. During core uncovery a release of fission products, such as the gap release, could occur at about the same time the hydrogen releases. The amount of fission products released to the containment is insignificant before core melting. The size distribution of fission products in the containment can be extrapolated from the CSE I14) experiments These experiments indicated that soon after fission
~'
product release, the mean particle diameter was 15 g.
A few hours later, the mean diameter decreased to about 5 a because of settling of large particles onto the floor. These sizes are substantially larger i
than those of dust particles and therefore, critical supersaturation is even smaller than values quoted above for the dust particles.
3.2.2 FOG FORMATION CONDITIONS Fog fomation in a mixture of vapor and noncondensible gases has been of interest to meteorologists, and turbine and condenser designers. Fog i s fomed by homogeneous or heterogeneous nucleation as a result of tem-l perature drop below the dew point (sometimes with concommitant pressure drop ). During the temperature drop, a local gas element will go through a series of themodynamic states. Eventually, a state is reached at ll which incipient fog formation occurs. Some degree of vapor supersatura-tion is needed to precipitate fog fomation. The vapor supersaturation at which rapid nucleation of vapor first appears is called critical supersaturation. The critical supersaturation, in general, is a func-tion of temperature, vapor properties, mixing time (if a mixing process is involved), and concentration and sizes of foreign particles. The critical supersaturation data for water has been given in Reference 15.
Fog fomation in an ice condenser containment as a result of homogeneous or heterogeneous nucleation could occur: (i) inside the themal boun-dary layer near a cold surf ace, (ii) in adiabatic or nearly adiabatic expansion of vapor jet, and (111) in mixing of a hot vapor stream with another cooler gas.
l 04300:1/101982 3-10
- - _ - ~ - _ - -
s...
,_.-y.,,
Surface cooling may create a region of local supersaturation within the thennal boundary layer, even though the bulk stream is still super-he ated. If the local supersaturation reaches the critical supersatura-tion, incipient fog formation will commence. This condensation mecha-I nism may exist in any compartment within the containment especially in the ice condenser where ice temperature is well below the dew point.
J i
When a high speed vapor - noncondensible gas mixture jet goes through an f
adiabatic or nearly adiabatic expansion, the gas mixture temperature and i
pressure will drop rapidly such that condensation may occur somewhere in the expansion process. This is the case when a hydrogen-steam mixture jet exits from a break at a supersonic speed. The jet experiences a rapid expansion and if critical supersaturation is reached, condensation shock may occur somewhere within the expanding jet. Thi s condensation mechanism can only occur in a compartment in which the hydrogen-steam mixture jet exists.
Condensation in a fast expanding vapor - noncondensible gas jet is a localized phenomenon. Since the jet expands into a superheated environ-ment in the lower compartment at the later time of the transient, little moisture would be generated in therexpanston process even if a condensation shock does exist. Therefore, the present study does not attempt to treat the condensation shock as a source of fog fonnation.
The third mechanism, condensation due to mixing, may exist in a compart-ment where a hot hydrogen-steam mixture mixes with a relatively cold I
containment atmosphere. During the mixing process, local critical supersaturation within the mixing gas could be reached and condensation would ensue. This mechanism could exist in the lower compartment in which relatively cold gas from the upper compartment i s returned by the deck f ans and mixed with the hot humid air.
Thus, the mixing of cold and hot vapor streams will be treated in the present study. However, only bulk condensation i s considered. That i s, it is not intended to compute the temperature profile to predict the I
3-11 04300: 1/101882 me e e -v e,n *
. ennemse e am
.- s eee m
t local condensation rate.
Instead, the bulk gas is assumed at one I
unifonn temperature, and bulk condensation will occur when mixing results in saturation conditions. This i s consi stent with the CLASIX code asstanption of unifom gas temperature.
i Before entering into the discussion of the methodology to calculate the j
fog formation rates from various fog fonnation mechanisms, a discussion of fog formation conditions is necessary. Since the bulk condensation approach for the mixing process has been adopted, the fog formation j
j conditions for the mixing process are simply that critical supersatura-tion is reached in the bulk stream. For practical purposes, the crit-ical supersaturation is assumed to be 1.0 since it is likely that plenty of condensation nuclei exist in the atmosphere before mixing condensa-tion takes place.
l 3.2.3 CONDITIONS FOR FOG FORMATION NEAR A COLD SURFACC i
Fog starts to form at a fast rate near a cold surface when local vapor supersaturation reaches the critical supersaturation. Near the cold surface, a thennal boundary 1 Ayer is fonned, within which local yapor pressure and saturation pressure varf. Typical vapor pressure and j
temperature profiles, when the incipient homogeneous nucleation first j
appears, are shown in Figure 3.2.
It is seen in this figure that when the local vapor pressure reaches the critical vapor pressure there is a sudden appearance of fog in the boundary layer due to the f ast nuclea-tion rate. Rosner and Epsteinill) have derived fog formation condi-tions near a cold surface, asstaning that the local vapor pressure curve is tangent to the critical vapor pressure curve at the fog inc;pient point. A more general fog fonnation criterion given by Hi,jikata and Mori(17) is 04300:1/101982 3-12
I h > (h)
(3.3) i W,
where aW = W T,
aT = T and the weight fraction of condensing vapor, W, can be related to the partial pressure of the condensing vapor P as y
(P /P) (M /M )
y y g (3.4) 1 - (P /P) ll - M /M )
y y g i
total pressure where P
=
l M
vapor molecular weight
=
I M
noncondensible gas molecular weight
=
I 9
Equation (3.3) may be rewritten as n>2 (3.5) j where 1
n=,2h/(h) wall The parameter n is used in the following section to calculate the fog fonnation rate.
It will be demonstrated that when n < 2, no fog fonna-tion is possible.
0430Q:1/102082 3-13 w
7 -
v
-.-_.m y
21123-3 s (
Pv, crit (T.)
j a
l I
I Pv Pv, eq(T=)
4 ev. =
I l
I lI I
i Ii I
II l
iI I
Perit (Tw)(
lg l
ll 1
Pv,w ll l
Y 0
=
I
, SUPERSATURATED,
REGION I\\
bm TRERMAL
~-
BOUNDARY LAYER M SUPERHEATED OR SATURATED l
fl VAPOR
- SUPERSATURATED REGION 9
I 8
1 T"
ht g
FOG D.P.lf a:
b 3
5 T
O
- Tn l
l I
I Sat l
3 Tw l
6 6
e FIGURE 3.2 VAPOR PRESSURE AND TEMPERATURE PROFILES NEAR A COLD SURFACE 3-14
~.. _ _ _., _. _
3.2.4 RATE OF FOG FORMATION NEAR A COLD SURFACE As has been discussed in Section 3.2.3, fog will fom near cold surfaces (e.g., in the ice condenser early in the transient.) As discussed in Section 3.2.1, once water embryos are fomed it takes only a few mili-seconds for them to grow to the micron size. After these micron size g
fog droplets are fomed, it needs very little supersaturation for fur-j ther growth. Therefore, in the present analysis, it is assumed that vapor and droplets are in themal equilibrium and local vapor pressure is equal to the local saturation pressure. This section is concerned with the transport of these micron-size fog droplets within the themal boundan layer.
I The boundary leer fog fomation rate can be determined using the Hijikata-Mori theoryIl7I of fog formation in the themal boundary l ayer.
It was assined that a thin liquid film, having a thickness of o g on a cold surf ace, coexists with a gas-droplet flow in a two-phase boundan layer of thickness 6 outside the liquid film as shown in 1
Fi gure 3.3.
It was further asstmed that the situratio'n' con'dition exists'within the two-phase boundary layer and the boundary layer approximation is appli-cable. Numerical solutions were obtained for the mass fraction of fog droplets, Y, at the gas-liquid film interf ace. The fog droplet flow o
rate at a distance X along the plate may be expressed in tems of Y as (6
f = L o f, Yudy (3.6) m mass fraction of fog droplets in the boundary layer where Y
=
fog drop 1,et density o
=
g 04300:1/101982 3-15
-+
w.
~.. - - -
5
/%
i i
5 i
I P
Main Flow Tw p
Wa c
I
-T~~
[
':3 p
[/
7 c
I O
Two Phase
[
Boundary layer 4
f
1 r L
I i f8 Tjv8 To
/////////// \\
nterf ace I
l O/////////////////////////
Liquid Film I
Cooling Surface t
FIGURE 3.3 FORtlATION OF F0G NEAR A COLD SURFACE I
5 i
I f
vapor density a
=
y f
l g
noncondensible gas density o
=
Y mass fraction of fog droplets at the wall
=
o y
coordinate perpendicular to the plate
=
i 1
fog boundary layer thickness j
6
=
width of boundary layer L
=
o py+ og Using the boundary layer approximations i
i Y=YO (1 - y/4)
(3.7) f (,Y )3 }
(f (,u )
Y (3.8) u=U u
j 6 (x) = a x 1/2 (3.9) l u=6 (x) (1 - c)
(3.10) s known constant where a
=
i known constant C
=
free stream velocity U
=
Substituting Eqs. (3.7) through (3.10) into Eq. (3.6), we have the rate of fog fonnation E
3-17 04300:1/101882 l
~ _.
_ -.. ~
i 0.25 025 (3.11)
"f
= pl 6 Y U,
)3 g
f Derivation of expressions for a, Y, and C is given in Appendix A.
o Even though boundary layer fog fomation may occur in any containment j
subcompartment, the fog fomation rate is likely to be small except in l
the ice condenser. For fog fomation in the ice condenser, L is the total length of the periphery of ice baskets and x is the height of the
'i ice bed.
During fog fomation in the boundary layer, heat transfer to the cold surface will decrease the bulk fluid temperature.
If the bulk fluid temperature drops below the dew point corresponding to the free stream vapor pressure, then bulk stream condensation could occur.
In thi s case, it is assumed that the boundary layer thickness, 6, will grow so l
thick that LsU, becomes the gas volumetric flow rate Q through the con-i densing compartment. This is a very conservative assumption in terms of the fog fomation rate. Under this assunption Equation (3.11) becomes
[0.25, 7.02 5 - T ~
(3.12) cond,, g y aj o (1-C (1,
y i
where m is the sun of boundary and bulk stream fog fomation rates.
cond i
3-18 04300:1/101882 i
N
= +w w ee.ww ww-'
ew
3.2.5 FOG DROP SIZES As mentioned earlier, when homogeneous nucleation comences, a large l
nunber of condensation nuclei are fomed and they grow to the micron I
size within a few milliseconds.
In heterogeneous nucleation, fog drop-lets grow on aerosol particles, which are usually less than 1 u.
In any j
case, the final drop sizes are determined by the atmospheric conditions I
with which the drops are in themal equilibrium.
II0I Neiburger and Chien studied the growth of cloud drops by condenu-tion and calculated droplet size distribution based on a cloud cooling rate of 6*C/hr. The initial size distribution of condensation nuclei (sodiun chloride) were chosen to correspond to available observations as I
shown in Figure 3.4 (designated as O second). The calculated drop size f
distributions at 3000 and 6000 seconds are shown in Figure 3.4.
It is seen that the diameters of fog droplets range from 0.01 a to 20 u.
The l
volume mean drop diameters are 8 a and 12 a at 3000 and 6000 seconds, respectively.
In the present study, a mean value of the volume mean drop sizes, i.e.10 u, is chosen for fog deposition and inerting c alcul ations. This is consistent with the observation of valley fogs of volume mean drop diameters ranging from 9 to 14 u(30) i 3.3 FINE MIST DROPLETS FROM CONTAINENT SPRAYS 1
i The containment sprays produce fairly large drop sizes. A typical con-tainment spray nozzle, e.g., Spraco 1713 nozzle, produces the size dis-tribution as shown in Figure 3.5, using a pressure difference of 50 psi across the nozzle (19I.
It is seen that water droplets produced from
]
containment spray range from 100 a to 2000 u.
These large drops have little potential for raising the lower flammability limit, as already 4
demonstrated in the Fenwal tests (20) and more recent tests at Factory Mutual (21)
To affect the flammability limit of a hydrogen mixture, the drop sizes have to be smaller than about 20 u, namely in the fog drop size ranges. Since containment sprays essentially do not produce drops in this size range, containment sprays will not be considered as a means to produce fog droplets. Rather, it will be considered as a means to remove the fog droplets.
04300: 1/101982 3-19 l
n. -,.....
-g,
- )
'I 1@ g i.. n..-......).
....3=
m l
A
'i
'# e e
i'
=
p
-1 i
9 E!
N E
5 0
ses C r
2
=
=;
]
~
Z j
l I
s
'o' r
a j
s
=
i w
c
~
coor =
=
{
-g
=
1
\\
\\
(
19
\\
1:
aooo. l l _. _=a
=
=
O o
u i
to ' y
,=
L:
i I
~
I 3
l wt
-.5 E
=
=_
i io.2 y
=:
=
9 1
i i.....
...:- i i, i.,
to 2 to-'
te to' io2 l
l I
FIGURE 3.4 CLOUD OROP SIZE DISTRIBUTION PREDICTED BY NEIBURGER AND CHIEN l
l 3-20
-w -
- - +.
i l
s 8
R l rn 1
m t
b t
s e
.-. g n
N me oo
% =
s N
M t
s s o N e m
e e
s z
\\
-k M
Z o -
o e o
- z z
1 c
QC M
a m
=0 I
z a:
8-a i
b\\\\\\\\\\
hh\\\\\\\\\\\\\\ g" h%\\%%w s
a w
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
g -
h xx % NNN % % % NNN'%
5 LNN%x\\%%%\\\\%%%N%N i
ANN %%NxxNNNNxxxxxxxxxxxxxxxxxxx%xx%\\\\\\x O
\\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \\N g AN%xN%NN%NNS E
m N
e m
o N
N N
W a
I l
u e
e
,e o
o e
e o
n E
c e
w m
SIl011HVd 30 838 MON q
m W
CE D
C 3-21 w
4.0 FOG REMOVAL MECHANISMS IN AN ICE CONDENSER CONTAINMENT l
I In Section 3, the mechanisms of generating fog droplets were discussed.
l After these droplets are generated, they can be removed from the con-tainment atmosphere by gravitational settling, vaporization, contaimnent sprays, and impingement on structures. They can also coalesce with other drops during collision and form bigger drops. These bigger drops could easily settle out of the atmosphere under gravity. These fog i
droplet renoval mechanisms will be discussed in this section.
4.1 SETTLING DUE TO GRAVITY Drop renoval rates due to gravitational settling depend strongly on drop radi us. The removal rate increases linearly with drop terminal veloc-ity, drop concentration, and settling area. The relationship may be expressed cs (4.1) set " YtnA
)
where n is the mass of mist-droplets per unit volume, and A i s the set-tling area.
The tenninal velocity, Y, is a strong function of drop radius and the t
relationship is shown in Figure 4.1 (Figure 5 of Reference 6). For a 1000 a drop, its tenninal velocity is above 1 m/s, while for a 10 g drop, which is the typical fog drop size, its terminal velocity is only about 1 cm/s. Therefore, there is very little removal by gravity for fog droplets.
0430Q: 1/101982 4-1
3 4.2 AGGLOERATION After the fog droplets are produced, the droplets will undergo changes in the ntsnber density and size distribution with time, when drops col-1 lide with each other and coalesce. The agglomeration rate (No. of par-ticles per unit volume per unit time) has been found to be proportional to the square of the drop population density and the coagulation mecha-nisms deoendent rate constant K(22),
4 For drops larger than 1 u, the dominant mechanism is the difference in velocities between drops in adjacent streamlines. This is usually temed the velocity gradient coagulation. For drops smaller than 1 u, the velocity gradient effect becomes small, and drops are brought together by Brownian motion. This leads to greatly different agglomera-tion rates for different initial drop sizes. A typical agglomeration rate as a function of drop size in a moderately turbulent atmosphere is shown in Figure 4.2.
In Figure 4.2, the sharp rise of the agglomeration l
rate with drop diameter larger than 1 a implies tnat the larger drops agglomerate quickly to the maximisn stable size supported by the atmo-l spheric turbulence. The agglomeration rates for drops,less than 1 a are l
very small. Since most of the foHroplets ere-in micron size ranges, the agglomeration rate is not large.
It is assumed in the present analysis that the initial 4 a blowdown mean drop size will grow to 10 a (See Section 3.2.5).
Agglomeration as a separate mechanism for fog growth has been conservatively neglected.
l 4.3 VAPORIZATION Fog droplets suspended in the containment atmosphere are considered to be in themodynamic equilibrium with the surrounding gas. When the sur-rounding atmosphere becomes superheated or when the droplets are entrained into a superheated subcompartment, they can undergo vaporiza-tion or condensation.
l 04300:l/101882
m In the present analysis, it is assuned that water vap'or and mist drop-lets are in thermal equilibrium at all times. Therefore, the amount of vaporization or condensation will be detemined by the thermal equilib-rium state reached by the vapor and drops.
In other words, it is not
- l i
intended to model heat transfer between the drops and the surrounding gas, and thus detemine the vaporization rate. This is a good assump-tion for the small fog drop sizes.
4.4 REMOVAL BY SPRAY DROPS As mentioned above, the contaiment ! May droplets range from 100 a 2000 u, which are substantially larger than the fog droplets.
If fog droplets enter the spray zone, they will probably be removed by the spray droplets by colliding with them, since the spray drop volume is I
much larger than the fog drop volume. A simple analytical model is used in the present study which assumes that all the fog droplets residing in 1
the spray zone will be swept by the sprays to the floor with the spray drop removal efficiency E.
The spray removal rate may be e) pressed as sp sp c (4.2) m
=EQ M I'sp y
- - - ~ ~ -
spray drop removal efficiency where E
=
volumetric flow rate of sprays Q
=
sp volume fraction of spray droplets in the spray zone n
=
sp mass of fog in compartment volume V M
=
c 4.5 UTHER REMOVAL ECHANISMS Another similar mechanism for fog removal is the fomation of droplets in the ice condenser. These droplets which would be generated in the ice bed when the ice melts, would fall through the ice bed, and remove fog droplets from the flow through the ice condenser. This large quan-tity of water would be effective in removing fog droplets. However, due to difficulty in modeling this removal mechanism, it is conservatively neglected in the present analysis, s
04300:1/101882
_... i.
In addition to the removal mechanisms mentioned above, fog can also be removed by impacting structural surfaces. Due to the inertia of fog i
l droplets, substantial fog removal by impacting structural surf aces could occur when the drop-laden mixture flow passes through long, narrow, curved paths, such as ice basket flow paths, and f an ducts. Moreover, the centrifugal fon:e exerting on the fog droplets, when they pass through the fans, could cause the fog droplets to impact the blade sur-faces or other parts of the fans. These removal mechanisms are believed to be significant; however, they are conservatively neglected in the present analysis.
It is, therefore, belieyed that the present analysis i s very conservative.
1 f
1 j
i i
5 I
e h
4-4 04300:1/101882 1
me-
...w.
-w,-e-me...-
-7 r
_.m
,o 21273 1 TERMINAL DROP FALLING
'{ (
VELOCITIES IN t
4 10 STEAM AIR 0
E ATMOSPHERES
'4*
9 2
s p+ +
1 gt b'
'/
1.0 ;;-
a 1
'i y
0.10
=-
ruAsuLENT
=
AMINAA REGIME j
[
REGIME i
[
HATCHED REGION INDICATES:
50 < Re <55
' I ' I I "'
I'"
I I I I'II' 0.01 O.001 0.01 0.1 1.0 DROP RADIUS (CM)
FIGURE 4.1 TERMINAL VELOCITY AS A FUNCTION OF DROP RADIUS r
IN STEAM-AIR ATMOSPHERE 1 '
4
\\
10
-=
GRADIENT
+
"3 AGGLOMERATION 3
,, 3 a eg.3 s
q 10
-=
h h
h-100S1 e
y I 102
=-
2 BROWNIAN o
AGGLOMERATION 5
n = 10 CM 3
~
5 2
1 NET 3
RATE
~~
2 4
~
100 f f I I I Hl!
I I I H I!!
f IffM4 0.01 0.1 1.0 10 DROP DIAMETER (uM)
FIGURE 4.2 AGGLOMERATION RATES IN AIR BETWEEN EQUAL-SIZED DROPS 4-5 m
i 5.0 COG IERTING CRITERIA a
Recent hydrogen burn experiments conducted at Lawrence Livemore Labora-l tory indicated that substantial fog fomation could occur when saturated steam is discharged into an unheated vessel.
It appeared that this fog prevented a glow plug igniter from successfully igniting the hydrogen i
mixture in the vessel. The ability of fog in inhibiting and quenching of hydrogen combustion can be explained as follows. The fog droplets suspended in the hydrogen-air-steam mixture act as a heat sink that 1
could absorb a large amount of combustion heat, greatly reducing the pressure and temperature rises resulting from hydrogen combustion.
If droplets are sufficiently small such that they could vaporize inside the thin ( 1mm) flame front, the flame may be quenched or inhibited. For a j
f1'ame speed of 2 m/s, the drop residence time is of the order of 0.5 x 10-3 seconds.(24)
In such a short period of time, the droplets of initial radius less than about 4 u will vaporize entirely in the flame I
front.
l The quenching of a propagating flame is also governed by the distance i
between droplets. As the droplets become closely packed, the total j
droplet surf ace area available forenergy-To'ss" Tncreases. A critical spacing between droplets exists such that a large fraction of the heat released is absorbed, thus preventing flame propagation. This critical spacing is known as the " quenching distance", which is usually deter-mined by propagating flames in tubes.
5.1 PREVIOUS WORK s
The effectiveness of fog droplets in inhibiting or quenching a flame depends on its quenching distance, was detemined by Beman et al.(24) as d = [4V/S] crit (5.1) q where V is the gis volume and S is the heat transfer surface area. For various hydrogen-air mixtures, the data on the quenching di stance is 5-1 0430Q:1/101882
-"**=-e>*
wee===.>
e-e...
s s
shown in Figure 5.1.
In the suspended fog droplets, this volume-to-surface ratio (i.e., V/S) is equal to l
1 d (1 - n) 5 n
where d is the mean droplet dianeter and n is the volume fraction of water. When four times this ratio approaches the quenching distance, a critical droplet dimeter can be obtained as "d
3 (5.2) dc"Z l-e Using this criterion for quenching a flame, for a given volume fraction of water and gas composition, d can be detanni ned. The critical q
l droplet diameter then can be detennined from the above equation. The drop sizes less than the critical drop size are capable of quenching a flame.
A plot of Eq. (5.2) for two hydrogen concentrations is shown in j
Figure 5.2 5.2 PRESENT THEORY l
The previous theories do not model the heat transfer and combustion processes occurring between the burned gas and the suspended droplets.
A new theory has been developed, which models the heat loss and corrbus-ti on.
Consider a hydrogen / air / steam / mist droplets mixture in which a flame is propagati ng. The flame may be divided into three zones: heating zone, reaction zone, and post-reaction zone as shown in Figure 5.3.
The unburned gas at temperature T moves in the reaction zone with the u
laminar burning velocity S,
If the unburned gas density is o e u
u then the constant mast flow rate m is equal to pus.
The unburned u
gas is heated to ignition temperature Tj and burned in the reaction 5-2 04300: 1/101882 l
~
.O l
t i
Iq
$ _...\\
- =-~~-
.;,,i.
I 'i l \\ \\\\ l i
I l E
i / /i / /f I 1
! li\\\\N ill: 7
// // lI i
~
l i,
,. ' ~ -,'./s.
s s Ei i i N A! i v/1 i i i i
lll l l ll lIIl l'
4 y,
s
,,.,o l
f ~ (\\ T i i e i i e
i
/6 //'f
~
l,lIkkllll Y[
l
. q-
_ 3_=-
FIG. 5.1 MINIMUM IGNITION ENERGIES AND QUENCHING DISTANCE FOR HYDROGEN-0XYGEN INERT GAS MIXTURES AT ATMOSPHERIC PRESSURE N
5-3
.p2.;,7ii.; c=rrtustica i - --
(\\
4 :
j l
l r-t s=*'
i H
_. 4.
.;- t i
-Crop 1.et y. cgs wsa:h _~....; ',
i
-.i-.....
="
2ia*=*=
1 n
g.-_.
. amaveg pesa
= =_.a y.-
4 on-o'f-63.sT.:
-i
..- paga gro
,i n-.a
/
,/
~
l' t;
4-
.m.,1!e -fra'etion-o f-fi S
V c
-u-.=~ O S r
f.a. w :_?-
(d'
. 5-am '
t i
L--
-o r.
f.
i G- -.
f g_
. x..
.a. >.-
y_-
6
(.
y
- [
h p.
/l l
I
,s
/
g
.v...
/
y s
,2 1
- /
lX.73094
,V _.
1 L
I
/
4G
- U.O4
.is.i J af [
f
_er f i
,/
s s
/
s
-.. /: /'
l nn,.
, ja a os
,4 4 _,.
6 4 p-
'4ATERICONTENT--H-(by-.vo.lume.'
i _;,
... i FIGURE 5.2 THE EFFECT OF DROPLET SPACING ON FLAME QUENCHING 5-4
,._-____-m---
e-
. - ~...
?
zone to reach the flane temperature T. The fog droplets will act as f
a heat sink that redt.ces the flame temperature. The problem has been I
fonnulated and solved by von Karman(25)
In his formulation, three energy equations, which incorporate the heat loss tenns, were written i
for the three zones described above. The solution to these equations yields the following relationship i
j=fl-exp(-fa)gy 2
,y) i 2 Ke f
x [1 + J 1, [4 gj,)2 j f x fl f Z
gj 5p (Tj - T )/4 where og
=
u i
t
/ C / Iw p
1 g
(S/C w) ej Ke
=
p I
the ratio of heat loss rate per unit voltane to the
=
heat release rate by chemical reaction per unit t
volume heat of combustion
=
q C
mean specific heat
=
p 5
heat conductivity
=
reaction rate (mass of fuel consumed per unit time w
=
per unit voltsne) 5-5 04300:1/101882
d.
Y hydrogen mass fraction in the heating zone
=
Y f hydrogen mass fraction in the reaction zone
=
ou Su m
=
,4 A plot of Eq. (5.3) is shown in Figure 5.4.
It is seen that for a given u - Y )/ej. Below thi s mini-Ke, there is a minimum value of (Y
'l f
j mum value, there is no solution for the /ej a.
Therefore, this value is considered as the flamability limit. At the flammability limit, the value of Kej can be determined from Figure 5.4 or from Eq. (5.3) as i
u - Y )/et)
(5.4)
(K) crit ej = f ((Y f
A plot of (K) crit 81 as a function of (Y - Y )/ej is shown in u
f Figure 5.5.
Equation (5.4) may be expressed as i
2 u
f q p "u Su (Y -Y)f u
f i
(5.5)
,d j;
12 -2(T
-T)_
g Detailed derivation procedure for Eq. (5.5), i s given in Appendix B.
Using the data on Su from Reference (26) we can calculate the right hand side of Eq. (5.5) for a given composition and initial gas tempera-ture.
5.3 VERIFICATION OF THEORIES BY EXPERIMENTS Experiments have been conducted at Factory Mutual to study the effects of water fog density, droplet diameter, and temperature on the lower flamability limit of hydrogen-air-steam mixtures (21)
The results indicated that most of the fog nozzles tested at 20*C only changed the limit from 4.03 volume percent to 4.76 percent, corresponding to fog concentration in the range of 0.028-0.085 volume percent, and volume mean drop size ranging from 45-90 microns. For the 50*C case, the lower 5-6 0430Q:1/101882
.m r - - - -
1 i
)
/
i i r.
7
.rj i
I<.wr,-ry.-
4 wam
% =. <ni
% - - co
,.O om t
FIGURE 5.3 SCHEMATIC REPRESENTATION OF TEMPERATURE PROFILE THROUGH THE FLAME FRONT i
4 9
(~
l l
l zl.a l
I
[l
- .0@
l JO*0 f I
l 00 Jk.0 20_l l
l h0^
f n..ax \\
o.2 A
v o-I i
O 2
4 5
6 O
12
<r,-r,/s, FIGURE 5.4 THE PARAMETER K p AS A FUNCTION OF t
(Y 0 FOR DIFFERENT VALUES OF K0
~
u p
\\
l i
5-7
,s
it n" guL
\\
8 0,
/
)
f Y
7 Y
(
F O
N 6
O I
TC NUF A
5 S
A T
I
- M 0
/
I L
)
g Y
Y 4
T I
u L I
Y B
(
ANM L
.I
',i 3
F E
l i
l TA 0
2 g
)
K
(
1 5
5 ERUG I
F 0
3 2
1 0
0 0
0 0
s-A'>E i
m
~
Ii i:
i l
4 1,
I
_ - ~.
flammability limit increases to 7.2 percent, corresponding to 0.01-0.04 l
volume percent of fog and 20-50 micron volume mean drop sizes. The f
results demonstrated that the fog inerting effect is more pronounced at small drop sizes.
I Figures 5.6 through 5.8 show the comparison between the test data and the theoretical predictions. For this comparison, the present theory used the free stream temperature to calculate the thermodynamic proper-i ties used in Equation (5.5). This yielded somewhat higher fog concen-l trations than those calculated by use of the mean of the flame and free stream temperatures.
In Figures 5.6 and 5.7, the data suggests a linear relationship between the volune concentration and volume mean drop size on the log-log plot.
It also suggests that the minimum fog inerting concentration varies approximately with the square of the volune mean drop size.
In this regard, the present theory seems to be more consistent with the data than the Bennan et al. theory.
The present theory is in good agreement with the Factory Mutual data at 4.76 pert:ent H ; however, it overpredicts the minimu fog inerting 2
concentration at 7.2 percent H. The cause of this discrepancy is 2
f still unknown. The discrepancy.ma7_be.cau' sed by the uncertainty of the data. The following discussion supports this claim. The fog droplets are very small and they vaporize very fast in a flame. Therefore, the fog droplets behave as steam except for their larger heat absorption J
capability. When the fog droplets vaporize, they absorb the heat of vaporization which is much larger than the steam sensible heat. Ty p-ically, the heat of vaporization of water i s about 1000 Btu /lb and the average specific heat of stean in the temperature range of interest is about 0.48 Btu /lb. It is well known that a hydrogen flame cannot propa-gate in steam higher than about 64 percent in a steam-air mixture. At 7.9 percent H, the adiabatic flame temperature is about 1240*F and 2
therefore the increase of the steam sensible heat is about 540 Btu /lb.
Consequently, for the same acount of fog droplets and steam, the fog droplets heat absorption capability is about 1.9 times higher. Thi s means that the fog concentration which is equivalent to 22.1 percent steam in steam and air is capable of inerting 7.9 percent H. Thi s 2
5-9 04300:1/101882
s-
1 l
r
.a g
oSpreco 2163 ASpreco i405-0604.
CSpreco 2020-1704 0
a vSpreco 1806-1605 a
t I
5 E
10 R
~
~
t
(
o NON-FLAMMABLE ZONE m
O m
C PRESENT THEORY"
~
i 8
~
O
.f M,_
(.
g 10-3 g
FLAMMABLE ZONE g
THEORY
/
..,.,i
......i i
ia*
10 10 0 200 VOLUME MEAN DIAMETER, MICRONS FIGURE 5.6 COMPARISON BETWEEN THEORIES AND FACTORY MUTUAL FOG INERTING EXPERIMENTS ON 4.76 PERCENT H2 5-10
['
10'3 i
i i
i i
i i
l 9
o spreco 2163-7604 1
8 7 Spreco 2020-1704
]
OScnicere 035H 7
i o
g
$5 "g
Non-Rammable
'_~ 4 Zone mt! 3 R c m m able C
h Zone PRESENT THEORY g
!2 T2% H2 n Air At~ 50*C-i 3
O 1
99 s
i i
i i
10 l
10 20' 30 40 50 60 70 S.0 90.
l VOLUME MEAN DIAMETER, MICRONS.
FIGURE 5.7 COMPARISON BETWEEN THE PRESENT THEORY AND FACTORY MUTUAL FOG INERTING EXPERIMENTS ON 7.2 PERCENT H2 0
1 5-11 l
^
~
f
~
10 A
l 1
'/
. l.
- i..; ;
-3 5 X 10 Z NON-FLAMMABLE ZONE
/
- l
~ ~ ' '
/+ PRESENT THEORY E
i, m
-i 1
C s
/:
o N
-/
i i
~-
I-6 it i 6 i ise.,st i e ilio
!:n[
FLAMMBLE ZONE.
"s
- 3_
u.
10
=
l a
-r p
- /:
m I
-4 5 X 10 (z
a FACTORY MUTUAL DATA
(. _ g:
j O,N 7.9% H9 - IN. A..I. R..
8 u.
v tw r
6 1
i s
i 6.,
..i i
,,i.
,4 10 50 100 500 1000 VOLUME MEAN DIAMETER, MICRONS
(
FIGURE 5.8 COMPARISON BETWEEN THE PRESENT THEORY AND FACTORY MUTUAL FOG INERTING EXPERIMENTS ON 7.9 PERCENT H2 i.
5-12 i
I i '
l l
l !
I
- -,, - ~
m
,m--
1 I
1 fog inerting vomumetric concentration was calculated to be 1.61 x 10-4 i
ft3 g 0/ft3 To inert 7.2 percent H, a minimum fog concen-2 mix.
2 tration which corresponds to about 21.3 percent steam in steam and air
{
is required. This gives a minimum fog inerting concentration of 1.56 x 10-4 ft3 H 0/ft3 mix for 7.2 percent H2 These estimates 2
show that the present predictions are reasonable and conservative. The estimates are consistent with Factory Mutual data on 7.9 percent H2 but not on 7.2 percent H -
2 It should be noted that in the tests three fog concentration measuring techniques were used. These three techniques gave substantially dif-ferent results. The discrepancy is at least one order of magnitude di f ference. The fog concentration data presented in Figures 5.6 through 5.8 were obtained from one of the techniques.
In view of the uncer-tainty of the data, care must be exercised in using them for inerting analysis purposes. They should be used in conjunction with the present fog inerting criterion in the assessment of fog inerting potential in the ice condenser plants. Some uncertainty also exists in the present fog inerting theory. The maximum uncertainty associated with the under-prediction of the heat loss and temperature dependence of the thermo-physical properties is estimated to be +6'3 pir~ cent.
~
~
i It should also be pointed out that the Factory Mutual data and the pre-sent theory can only predict the minimum fog inerting concentration.
Estimates of burn completeness in just-flamable fog mixtures were not within the scope of the present effort.
1 0430Q:1/101982 5-13
i L
6.0 ASSESSENT OF FOG INERTING PROBABILITY IN ICE CONDENSER CONTAINENTS 1
As discussed in the previous sections, there exist several mechanisms of generating and removing fog droplets from the ice condenser contain-ment. In addition, fog droplets are aise transported from one subcom-l; partment to another by entrainment in the gas stream. The fog entrain-ment rate is difficult to assess without knowing the velocity field and i
)'
drop size distribution. For simplifying purposes, it is presently
]
assumed that the mass fraction of mist droplets in the interec:npart-mental and f an flows is the same as that within the subcompartment from which the flows are originated. Thi s i s a good asseption since 'the fog 1
droplets are small. The amount of fog droplets in a subcompartment depends on all these mechanisms.
The total amount of fog droplets is important in detennining the volune fraction of suspended condensate in a subcompartment. Thi s. volume frac-i tion, in turn, is used in the fog inerting criteri a to determine whether lf a particular hydrogen mixture composition fonned in a subcompartment at l
any time is flansnable or not.
In other words, by knowing the hydrogen
,j concentration and the mean fog drop size,7e'c'ait detennine whether the calculated volume fraction of fog droplets is high enough to prevent the mixture from combustion.
(i i
6.1 DETERMINATION OF VOLLE FRACTION OF MIST DROPLETS IN ICE CONDENSER CONTAINENTS Consider a subcompartment in the ice condenser containment as shown in i
Figure 6.1.. There exist several mechanisms by which mist drops can be i
generated or removed. Fog droplets can be generated by homogeneous or heterogeneous nucleation in the thennal boundary layer and/or in the bulk stream and they can increase in size by condensation or decrease in I
size by vaporization. The rate of generation of mist droplets by con-densation and their continued growth (or shrinkage due to vaporization is represented by in The other mechanism of generating mist drop-cond.
lets considered in this analysis is the primary coolant discharge from i
the break and the rate of generating fog droplets from this mechanism is 6-1 0430Q:1/101882 1
--mer...---
.. a. m.u.
n--
c
t represented by Sbre ak. Two fog droplet removal mechanisms are consid-
,f cred in this analysis: one is gravitational settling and the other is removal by containment spray. The fog droplet removal rate by gravita-tional settling is represented by iset and that by spray is represen-i ted by h In addition to the generating and removal mechanisms sp.
discussed above, the mist droplet concentration in a subcompartment is also affected by the intercompartmental and fan flows.
In the intercom-partmental and fan flows, the mass fraction of fog droplets entrained is n and the gas mixture flow rate is 5. Therefore the rates of fog drop-lets mass into and out of a subcompartment are Inin 5in and In Sout, respectively.
It should be noted that Inin b n out i
and Inout bout include the fog mass entrainment rates in all the
!j intercompartmental and fan flows into and out of a subcompartment.
The mass conservation equation for the fog droplets in a subcompartment may be expressed as
- c "
dt I"i n i n out out break
- cond ~
- set ~ "sp IO*1)
EU
~
where I is a summation over all the flow patits.' In Eq. (6.i), if
'~
cond is negative, then it becomes the rate of vaporization. E q.
m (6.1) can be integrated to give the total mass of condensate at time t t
f t) =i
( Ini n "in I'out out break
~
C sp) dt
+ *c cM ~
- set
~
i i
~
i i
i i
i r (Inin "in In
- break out out g
i i
i (6.2) cond ~ " set " *sp) at$
+m J
.l l
04300:1/101982 6-2
.-- -.m-4_.+,.y S-_yy..
- em y-r--
=
w
== - - - ~ *
-~
+T*-
The present analysis will employ the CLASIX calculations of containment transient during a small LOCA.
In the CLASIX analysi s, the entire ice condenser containment is usually divided into five or six subcompart-ments for analysis purposes. Temperatures, total pressure, steam partial pressures, and intercompartmental flow rates are calculated by CLASIX during transients. This infonnation is used in Eq. (6.2) to determine fog droplet mass.
When applying Eq. (6.1) to each individual subcompartment, we have the following fog mass conservation equations in finite difference fonn:
Upper Compartment MUC (t + at) = MUC(t) + (Inin i n(t)
(6.3) l
- Inout "out *
"UC,cond(t) 1 I
UC, set (t)-mVC,sp(t)}
-m at i
I Lower Compartment l
MLC (t + at) = MLC(t) + ( Ini n "i n C, break (t)
(6.4)
- I'out out
- kC,condItl-kC,setIt)-*LC,sht))
at 5-3 04300:1/101882 T
Ice Condenser Upper Plenum S
It)
Mup(t + 4t) = Mgp(t) + ( znin in(t) - z nout out i
+ kP,cond(t) - kP,setIt))
At Ice Condenser Lower Plenum M(p (t + at) = (p(t) + (Inin "in(t)
(6.5) out"out(t)+%P,cond(t)-mLP, set (t))at
- In t
Dead Ended Region 1
MDE (t + at) = MOE(t) + (Inin "in(t)
(6.6)
S It) + "DE, cord (t) - mDE, set (t)) at
- I"out out Fan / Accumulator Rooms
- I MFA (t + at) = YA(t) + ( znin min (t)
(6.7) out(t)+hA,cond(t)
- I"out S FA, set (
- *FA,sp(t) at m
In the present analysis, the fog concentrations in the intercompart-mental and fan flows are assumed to be the same as those in the compart-ment from which the flows are orginated.
These rooms were analyzed only for the D. C. Cook plant (See Figure 6.9).
04300:1/101982 6-4 g
--,,_.y--
In the equations given above, the intert:ompartmental and fan flow rates b
and Sout are provided by CLASIX calculational results. The in procedures of calculating fog droplets generating and removal rates are based on the discussions in the previous sections and the details are given in the following sections.
6.1.1 CALCULATIONOF$BREAK l
To date little experimental data is available to estimate the amount of fog droplets generated by the break flow. For a large LOCA, Almenas and MarchelloI3) estimated that 13 percent of the total blowdown drop population (by weight) has drop radius range from 1 a to 20 a and only 1 percent less than 12 This estimate is somewhat larger than the 4 a mean drop size sited in Section 3.1.2, which is believed to be conserva-ti ve.
}
Since we are only interested in fog drops smaller than 20 u, and only these drops can remain suspended in air until the time when the hydrogen
}
is released, we assume that the estimate of Almenas and Marchello is l
applicable in small LOCAs and 14 percent of the suspended liquid are fog droplets which have a potential inerting effect.
i The fraction of reactor coolant discharged from the break that remains as suspended liquid has been determined in Section 3.
Knowing the break flow rates from a computer code such as MARCH, we can calculate the i
amount of liquid suspended in the atmosphere. Then from the drop size distribution we can calculate the amount of fog droplets suspended in the atmosphere.
Defining the blowdown rate as E, the liquid fraction of the break b
flow as (b, the fraction of fog droplets smaller than 20 a as fbe we have (6.8) m
- I Cb break b
b 04300: 1/101982 6-5 1
I
'I In the present analysis fb = 0.14 i s used. f becomes zero when the b
- {
water level in the reactor vessel falls below the break elevation.
6.1.2 CALCULATIONOFSCOND is the rate of fomation of mist drop-As discussed previously, mcond ll 1ets by nucleation, condensation, or vaporization.
Nucleation of fog l
droplets can take place in the thermal boundary layer and in the bulk I
fl ui d.
We conservatively assume that little supersaturation is needed for nucleation in the bulk stream and fog will fom when the bulk stream steam partial pressure reaches the saturation steam pressure correspond-l ing to the gas stream temperature. Therefore, the bulk stream fog formation rates can be detennined from the equilibrium themodynamic states of the gas mixture.
g t
The bounaary layer fog fonnation rate can be determined using the Hijikata-Mori theory (17) of fog fonnation in the thermal boundary layer as di scussed in Section 3.2.4.
The fog fonnation rate in the thermal boundary layer and the bulk stream i s given by Eq. (3.12).
Boundary layer and bulk stream fog fonnation rates will be calculated for the ice condenser and lower coiiipartment.' The volunetric gas flow
~
rate, gas and wall temperatures, total pressure, and steam partial J
pressure were obtained from the CLASIX output.
6.1.3 CALCULATIONOF$2T The rate of settling of the fog droplets depends on their teminal velocity, concentration and compartment cross sectional area. The droplet tenninal velocity is a function of drop size.
In the present study, Equation (4.1) will be used to calculate the fog gravitational settli ng rate.
6-6 04300:1/101882
=
w -
+. -
6.1.4 CALCULATION OF $ p 3
The mass of a fog droplet is much smaller than that of a spray droplet.
Therefore, when a spray droplet collides with a fog droplet, the fog droplet will coalesce with the spray drop and f all to the sunp. In the 1
present study, the fog removal rate by sprays is given by Equation (4.2).
)
{
It is expected that the spray drop collection efficiency is very high, and therefore a 100 percent drop collection efficiency is assuned in the analy si s.
A sensitivity study was carried out to study the effect af E on the volume fraction of fog droplets and will be discussed later.
6.2 F0G INERTING PROBABILITY IN THE SEQUOYAH PLANT To compute the fog fomation rates some output data from the Sequoyah CLASIX analysis (27) are needed. These data include time histories of I
gas temperature, wall temperature, total pressure, and steam partial pressure in each contaiment subcompartment, as well as the intercom-partmental and fan flow rates. The subcompartmentalization model used in the Sequoyah CLASIX analysis is shown in Figure 6.1.
In thi s study
~
only the S 0 accident scenario has been analyzed.
2 The input data for Sequoyah S D Case 1 are given in Tables 6.1 and 2
6.2, and the calculational results are shown in Figures 6.2 and 6.3.
In Figure 6.2, the fog fomation rate in the lower compartment is shown.
For the first few hundred seconds the wall temperature is lower than the dew point corresponding to the steam partial pressure and therefore fog starts to fom. After about 600 seconds, the fog fomation rate becomes negligibly small since the wall temperature is only a few degrees below the dew point. There is no fog fomation in the lower compartment after about 1800 seconds. The fog fomation rate in the ice condenser is shown in Figure 6.3.
It is seen that the fog fomation rate in the ice condenser is much larger than that in the lower compartment.
It increases with the ice condenser steam flow rate and reaches a peak of 6-7 04300: 1/101882 i
- 1
'l
'l 11 (~
FIGURE 6.1 SEQUOYAH CLASIX CONTAINMENT MODEL
'i
{
ICE CONDENSER UPPER UPPER I
f PLENUM COMPARTMENT I
I A
A i
i i
ICE SED I
- g _- ____
j f
Y Y
I ICE i
+ _a CONDENSER t
LOWER LOWER ENDED PLENUM C5. MPART. MENT REGION s
t
~ ~ "
AIR RETURN FAN / HYDROGEN SKIMMER SYSTEM FLOW PATH CONTAINS DOORS 1
5 FLOW ALLOWED IN SOTH OIRECTIONS 1
FLOW ALLOWED IN ONE DIRECTION rTrTrTrzTrz SPRAY HEADER 6-8
14 lb/sec at about 1800 seconds. The fog fomation rate in the ice I
condenser then begins to decrease and is low at the time of significant hydrogen release.
The input data needed to calculate the rate of fog generation by the break flow, the fog settling rate due to gravity, and the fog removal rate due to sprays, as well as the rates of fog entraiment by inter-i compartmental and fan flows are discussed as follows.
The rate of reactor coolant release to the containment and the coolant j
enthalpy were obtained from the MARCH outputI7) for a small LOCA. The quality of the break flow was calculated using the enthalpy and the lower compartment gas temperature. According to the MARCH predic-tion (7) the discharge of liquid by the creak flow into the lower com-partment lasts for only 2172 seconds. Afterward, the water level in the reactor vessel drops below the break elevation and the fluid discharged from the break is essentially steam. Therefore, in the present study, it is assumed that no fog is generated by the break flow after 2172 seconds.
For fog removal by gravitational settling ~, a~v~olume mean drop size of 10 a was assumed. The teminal velocity of a 10 a drop is about 1 l
cm/sec. Because of this low teminal velocity, gravitational settling
}
is not an effective fog removal mechanism. The assumption of 10 a volume mean drop size is therefore conservative, considering the f act I
that for a few thousand seconds the drop agglomeration mechanism would be able to increase volume mean drop size substantially.
It should also be noted that a smaller volume mean drop size means that the minimum fog inerting concentration would be reduced and thus makes the present analysis conservative. Furthemore, no consideration was given to the deposition of fog on the walls and vertical surfaces of the structure, or for fog removal in the f an flows when it passes through duc+.s and fans. All the assumptions mentioned above make the present analysis very conservative. The containment geometric data needed in computing the settling rate are given in Table 6.3.
0430Q:1/101882
sh O.OOOn i
T N
E M
T R
A P
M O
O.OOO, C
R E
W O
L H
A Y
0 0
O.OOOm 0
[
5 A
V I
2 6
l i
E
. w.
l U
N O.OOO< G u
"f
.L,.i F
I 0
l l
l
)
A C
E M
5 R
(
0 f
E M
C
~
~
I O
~
O.OO=.
1 F
~
O.O 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
5 4
3 2
1 f
0 0
0 0
0 O
0
- 3. 1sVNDav J ~- 4W zo trIxOt cot A
i L
L LI n1 c
i t:
ii:
ll ljI!
/ -
}
0*0005 C
i w
5 l
A=
-=
w
' 0'000#
ce C
w Z
2 m
=
5 u
a v
d
=
a C
0*000E 5
a 3
C" c:r bi w
i.r z
,\\
/
l 0*0002 g
~
2 x
C O
l A
y 4
W C$
M Z
CE:
m C
w I
Z d
Q C
E
'N 0'0001 O
NI 8
N t
N i
00 c
C C
C C
C C
C O
c C
C C
C C
C C
D C
C C
C C
D C
C.
c.
D.
e o
e c
c na C
=
N AJ C
=
9 (335/87) 31vu N011VWB03 003 6.-11 I
. -. ~..
__m i
For fog removal by sprays, a spray flow rate of 9500 gpm was used for Sequoyah. According to the Sequoyah CLASIX analysi s(27), the sprays are initiated at 142 seconds. A volume fraction of sprays (volume of sprays divided by volme of the spray zone) of 3.3 x 10-4 was used, I
which was obtained using a spray drop fall height of 107 ft, a spray 3
zone volume of 485,500 ft, and a volme mean drop size of 700 a.
As previously discussed a spray removal of a 100 percent was used.
i t
In Figure 6.1, the directions of the intercompartmental flows are shown. The intercompartmental flow rates for the six flow paths and nine time steps were obtained from the CLASIX analysis and are given in Table 6.5.
The present analysis considers the interrompartmental flows as the mechanisms of transporting fog from one compartment to another.
l It is seen in Figure 6.1 that two trains of the air return f an and hydrogen skimer system take suction from the dead ended region and from the upper compartment and discharge into the lower compartment. The fans are initiated at 712 seconds. The f an head-flow curve reported in Reference 27 was used to compute the f an flow rates. Fan flow rates of 3
3 1645 ft /sec and 10 ft /sec were used for the air return f an and the hydrogen skimmer system, respectively. T}iese 'fiow rates were calculated using average ap's between the upper compartment and the lower compart-ment, and between the dead ended region and the lower compartment.
3 The results of the calculation are shown in Figure 6.4.
It is seen that for the first few hundred seconds the fog concentrations in the lower compartment, ice condenser lower and upper plenums are about the same j
and increasing. At about 700 seconds, the lower compartment volumetric fog concentration reaches its peak of 2.2 x 10-4 ft3 H 3
20/ft mi x. Afterward, the intercompartmental flows transport more fog droplets out of the lower compartment than are generated by the break flow and condensation and, therefore, the lower compartment fog concentration decreases. However, the upper plenum fog concentration keeps rising until about 900 seconds, due to an increasing fog fonnation in the ice condenser and more fog entrained in the intercompartmental 0430Q:1/101982 6-12
tc flow into the upper plenum. The upper plens fog concentration reaches 3
its peak of 5.4 x 10-4 ft3 H 0/ft mix at about 900 seconds.
2 The lower plenum fog concentration is almost the same as the lower compartment fog concentration because of little difference in the inten:ompartmental flow rates into and out of the ice condenser lower pl enum. Therefore, these two volmes behave as a single volme in tenns of fog concentration.
At 2172 seconds, the break flow in the lower compartment stops genera-
]
ting fog and, therefore, the fog concentrations drop sharply there-after. The effect is more pronounced for the lower compartment and lower plens fog concentrations. The highest fog concentration exists in the ice condenser upper plenum while the lowest exists in the upper i
compartment. The effect of sprays on the upper compartment fog concen-tration is clearly seen in Figure 6.4.
At 142 seconds, the sprays are turned on and the upper compartment fog concentration drops sharply until about 600 seconds. At about 600 seconds, the upper compartment fog concentration starts to increase again because the intercompartmen-tal flow into the compartment increases sharply at that time. A peak 3
l concentration of 7 x 10-6 ft H 0/ft mix in the upper compart-2 ment is reached at about 1200 seconds.
l Hydrogen starts to release into the coctaiment at about 3804 seconds, according to the MARCH calculation (27)
It reaches 4 volume percent at about 4300, 4400, and 4670 seconds in the lower compartment, upper plenum, and upper compartment, respectively.
At 4300 seconds, the calculated lower compartment fog concentration is 3
3 9.7 x 10-7 ft g 0/ft mix, which is about an order of magnitude 2
smaller than the minime fog concentrations required for inerting 4 percent H. At 4670 seconds, the upper compartment fog concentration 2
3 3
is 1.35 x 10-6 ft H 0/ft mix, which is about a factor of five 2
smaller than the minimum fog concentration required for inerting 4 percent H *. At the times of reaching 8.0 percent H, the fog 2
2
- The fog inerting criteria is described in Section 5.2.
3 0430Q:1/102082 6-13
-m a
e
m_,
1 0'0009 j
fp J
.I,
e..,
~
il i
c iP w
m I
.I,
Ir c--
m a
t S,
m L
p i
s
~l I
e 1
E.v Jw i
jp 5 0'0005 e
=
f i i, z ii -
c.
i
/
I m C i
n I,'
f N
w I
z z *=
?
9 t.
cC" d
,[
[]
t n
uz w
2f<
g -
0'0004 C
w cp 4
>- r*
.I i
cC w y, ni u
i.s i
e2 I
w c c'
.ar.s m a c
.r.s c-m u 0'000E
-J$
p-17 ),-
i zku e,
,p y
g C
'), ls.
J1 7
m
+
w n,e A
't ff l(
c g
,(
-Im e
u,,, Y, a
ZC ll l
l wv"
~
0*0002 O C
z=
m i.n
. i.
ewz i
uzC m
W C 2 I
e caw m i sIi 3
e ii a
+
w-e e
1, e
I
,- l Of0001
.\\j s
\\
R
?
...---s s
1 ;w e
n n
l
~ %,
}%
/
n!:,c,
.--y j
0*0 ru o tnto texo.:s w w a:r ~. ~ ~ rc:mem e CCZD CC CCC CC CCCD CC CCC CC C i e iii iie i6 iia ia a e a i i
CCC CC CM mN 4a CP.u9 M N --CC CC M w h w e w e L.us.a
--ec ec c ce ec CCe oc cx=> cc - co w ea e CCC CC CXZ3 CC C CCC CC CCC CC C.CCD CC. CCC CC.
CCe Co Cc=3 ee w meu
--~u, meu
--~u, mm ~ mm -
( X I W E **13 / 0 2 H E **13) NOI1VB1N3]N0J 003 6-14
concentrations in the lower and upper ccmpartments are even lower than the figures given acove.
Therefore, it is concluded that the fog concentrations in the lower and upper compartments are too low to have any inerting effect. The use of the present theory on fog inerting also leads to the same conclusion.
i However, at 4400 seconds, the calculated fog concentration in the upper 3
3 piene is 6.1 x 10-5 ft H 0/ft mix which is higher than the 2
Factory Mutual fog inerting data extrapolated to 10 u drops and the present theoretical prediction. The data shows that in oMer to inert 3
the fog concentration must be 8.4 x 10-6 ft 4.76 percent H2 3
2 /ft mix or higher for 10 a volme mean drop size. At 4600 H 0 seconds, the upper plenum hydrogen concentration reaches about 7 pement 3
3 and the fog concentration is 5.5 x 10-5 ft H 0/ft mix. Agai n, 2
an extrapolation of the Factory Mutual data to 10 a. shows that fog 3
3 concentration of 2.1 x 10-5 ft H//ft mix or higher is required to' inert 7.2 percent H.
In comparison, the present theory 2
3 3
on fog inerting predicts 1.02 x 10-4 ft H 0/ft mix for 7.2 2
l percent H -
2 Therefore, it appears that it is possible to inert 7 percent H2 but unlikely. However, at 8 percent H2 in the upper plenum, which occurs 3
at about 4650 seconds, the fog concentration is 5.5 x 10-5 ft H 0/ft mix, which is too low to inert 8 percent H. An extrapol-2 2
4 ation of the Factory Mutual 8 percent H2 data to 10 a volume mean drop 3
size and the present prediction give 1.9 x 10-4 and 1.2 x 10-4 ft 3
H 0/ft mix for the minimum required fog inerting concentration, 2
respecti vely. Therefore both the theory and the extrapolation of test data show that fog inerting will not occur in the upper plenum.
The glow plug igniters which have been installed in the Sequoyah con-tainment were designed to burn hydrogen at the lower flammability limit. As discussed previously, no fog inerting effects will be expected in the Sequoyah lower and upper compartments.
Therefore, the glow plug igniters are expected to function as designed in these two 0430Q: 1/102082 6-15 4
e m
compartments.
It may be possible that fog present in the ice condenser upper plenum could prevent the glow plug igniters from igniting hydrogen below 7 percent. However, it seems very unlikely that the same igniters would f ail to ignite 8.0 percent H2 given the fact that considerable i
conservatism has been exertised in the present analysis. CLASIX analyses have previously been perfomed that showed the Sequoyah J
containment response to burning 8.0 percent H2 mixtures would be l
acceptable.
Sensitivity studies of the spray removal efficiency and the fraction of blowdown droplets smaller than 20 g for the Sequoyah plant have been performed. A case of 10 percent spray removal efficiency was investi-gated. The calculational results showed that the fog concentrations in the lower compartment, lower plenum, and upper compartment at 4600 seconds were increased approximately by a factor of 10. However, these 1
concentrations are still too low to inert 8 percent hydrogen.
In com-parison, the fog concentration in the upper plenum is increased by only 20 percent because the concentration at this time is primarily deter-mined by the fog fomation rate in the ice condenser. This increase is too small to change the conclusion given previously on the inerting probability in the upper plenus. Another case in which all the blowdown droplets were assumed to be smaller, than 20 a was investigated. The calculational results showed that at 4600 seconds the fog concentrations
~i
. in the lower compartment and lower plentan were increased by 15 percent while the increases in the upper plenum and upper compartment were negligibly small. The insensitivity of the fog concentrations to the parameter of the fraction of blowdown droplets smaller than 20 u is due to the effectiveness of the spray removal. At 4600 seconds, almost all the blowdown droplets are removed by the sprays. The sensitivity studies showed that the fog concentration in the upper plenum at the time of significant hydrogen release is not sensitive to the spray removal efficiency and the fraction of blowdown droplets smaller than 20 u.
04300:1/101882
TABLE 6.1 INPUT DATA FOR SEQUOYAH LOWER COMPARTMENT Steam Lower Compartment Gas Wall Total Parti al Gas Flow Rate Temp.
Temp.
Pressure Pressure 3
Time (sec)
(ft /sec)
(*F)
(*F)
(psia)
(psia) 60 1404.5 150 118 16.7 5
610 646.7 215 202 21.6 15.3 1210 3157.2 188 176 20.4 8.9 1810 3115.5 188 176 20.5 8.8 2410 2913.7 180 173 20.1 7.5 3010 2871.7 179 169 19.9 7.2 3510 2739.3 178 169 19.9 6.9 I
4010 2755.9 175 164 19.4 5.5 i
4510 2848.8 197 173 19.8 4.8 i
o A
l 6-17 04300:1/101882
-~--
w
,p.
m
TABLE 6.2 INPUT DATA FOR SEQUOYAH ICE CONDENSER Steam Ice Condenser Gas Ice Total Parti al Gas Flow Rate Temp.
Temp.
Pressure Pressure 3
(ft /sec)
(*F)
(*F)
(psia)
(psia)
Time (sec) 60 1082 120 32 16.5 2.5 I
610 96.4 132 32 21.8 2.3 l
1210 2654 186 32 20.4 8.1 1
1810 2799 188 32 20.5 8.8 2410 2679 182 32 20.0 7.6 3010 2629 179 32 19.9 7.2 3510 2502 178 32 19.9 7.0 4010 2594 171 32 19.4 5.7 4510 2628
.87 32 19.8 4.7 i
l i
6-18 04300:1/101882
TABLE 6.3 GE0ETRIC DATA FOR SEQUOYAH CONTAINtENT 3
2 Vol ume (f t )
Floor' Area (ft )
i Lower Compartment 289,000 5,410 Ice Condenser Lower Plenum 24,200 3,100
.i Ice Condenser Upper Plenun 47,000 3,200 Upper Compartment 651,000 10,390 Dead Ended Region 94,000 3,350 i
i i
6-19 04300:1/101882 w
g
TABLE 6.4 MARCH PREDICTION OF REACTOR COOLANT MASS AND ENERGY RELEASE RATE FOR THE S D SEQUENCE 2
Time H O Mass Release Rate H O Energy Release Rate 2
2 (seconds)
(1bm/sec)
(Btu /sec) 0.0 197.2 1.167 x 105 2172 190.5 1.097 x 105 4
2478 44.85 5.230 x 10 4
3180 53.53 6.547 x 10 4
3804 34.82 4.262 x 10 4
4428 21.40 2.842 x 10 4
4752 48.42 5.558 x 10 4
5700 19.42 2.182 x 10 6012 14.07 1.583 x 104 6960 5.253 5.989 x 103 l
7062 4.718 5.388 x 103 3
7206 4.060 4.693 x 10 l
l t
6-20 0430Q:1/101882 e
r--.---
-m
\\
i 3'
TABLE 6.5 INTERCOMPART! ENTAL FLOW RATES (ft /sec)
PREDICTED BY CLASIX FOR SEQUOYAH Time Flow From Flow From Flow From Flow From Flow From j
(sec)
LC to LP LP to UP UP to UC UC to LC DE to LC 6.001E l 1.175E 3 1.082E3
- 7. 029E 2
-9. 905E l
-1. 304E 2 6.100E2 3.580E2 9.641El
-3.931E l
-2.113E1
-2.676E2 1.210E3 2.864E3 2.654E3 1.272E 3
-1.838E2
-1. 094E 2 1.810E3 2.82E3 2.799E 3 1.323E3
-1. 793E 2
-1. 088E 2 2.410E 3 2.695E3 2.679E 3 1.375E 3
-1. 502E 2
-6.855El 3.010E3 2.654E 3 2.629E 3 1.407E3
-1.634E 2
-6.326El 3.510E 3
- 2. 528E 3
- 2. 502E 3 1.352E 3
-1.643E 2
-4.699E l 4.010E3 2.613E 3 2.594E 3 1.537E3
-1. 095E 2
-3.348E1 4.510E3 2.694E3 2.62E 3 1.627E3
-1.106E 2
-4.426El I
I i
I l
1 1
i i
04300:1/101882 g
-&---v
m.._-
6.3 FOG INERTING PROBABILITY IN THE McGUIRE PLANT To compute the fog formation rates some output data from the McGuire CLASIX analysis (28) are needed. These data include time histories of l
gas temperature, wall temperature, total pressure, and steam partial pressure in each containment subcompartment, as well as the intercom-partmental and f an flow rates. The subcompartmentalization model used j
in the McGuire CLASIX analysis is shown in Figure 6.5.
In this study only the S D accident scenario has been analyzed by CLASIX for McGuire.
2 The input data for McGuire S 0 Case 1 are given in Tables 6.6 and 6.7, 2
and the calculational results are shown in Figures 6.6 and 6.7.
In Figure 6.6, the fog fomation rate in the lower compartment i s shown.
For the first few hundred seconds the wall temperature is lower than the dew point corresponding to the steam partial pressure and therefore fog starts to fann. The fog fonnation rate is low because the wall tempera-ture is only a few degrees below the dew point. Fog fonnation in the lower compartment becomes zero after about 600 seconds. The fog foma-tion rate in the ice condenser is shown in Figure 6.7.
It is seen that l
the fog formation rate in the ice condenser is much-larger than that in the lower compartment. The fog farmatiorr Tate' Tncreases with the ice condenser steam flow rate and reaches the first peak at about 1510 seconds. Then the rate decreases because of the decrease in the steam flow rate. The fog fonnation and the steam flow rates start to increase again at about 2510 seconds. The fog fonnation rate reaches the second peak of 10.2 lb/sec at about 3260 seconds.
1 The input data needed to calculate the rate of fog generation by the f
break flow, the fog settling rate due to gravity, and the fog removal rate due to sprays, as well as the rates of fog entrainment by intercompartnental and f an flows are discussed as follows.
The rate of reactor coolant release to the containment and the coolant I7I enthalpy were obtained from the MARCH output for a small LOCA. The quality of the break flow was calculated using the enthalpy and the 04300:1/101882
i FIGURE 6.5 MCGUIRE CLASIX CONTAINMENT MODEL j
1 i
1 i
McGUlRE CLASIX MODEL i
~
~
ICE CONDENSER UPPER HYS i
m UPPER l
PLENUM COMPARTMENT l
i i
A A
l i
I I
l i
ICE BED i
i l
i Y
Y ARF ICE 4--
DEAD CONDENSER LOWER ENDED 4
LOWER 4
PLENUM COMPARTMENT l
AIR RETURN FAN / HYDROGEN SKIMMER SYSTEM i
FLOW PATH CONTAINS DOORS l
4 5
FLOW ALLOWED IN BOTH DIRECTIONS 4
FLOW ALLOWED IN ONE DIRECTION SPRAY HEADER G-23
'*~"
' e wee y
l 0:0006
-x w
z e<
c t
I t,
v 0'000t m
w 2ca W
m m
o 0'000E vz w
I L
=o e
e
=
w
~
I,
~
5 r
-J.
O'0002 c a
s u
j z
w e
o i
C
~
u
'O e
0'0001 ~
O'O o
C O
O O
o O
O C
O o
O O
O O
c e
m cu o
e o
o o
o o
1 (33S/87) 31VS N 011V W 8 03 003 i
6-24
- - ~ =.
i 0*0005 l
i l
/
=
w i
z w
C a
i z
0*000*
j Cv t
I w
i d
/
/
w=
3 1
C" 0*000E 1
N v
I w
s.
e g
j C*
i E8 z
0*0002 2
0 I
w e
w Cw w
a 1
C 0*0001 -
i 0*0 C
C C
C C
C C
C C
C C
C C
C C
C C
C C.
=
=
=
N O
==
=
N N
Q (33S/87) 31v 8 N011YW803 903 6-25
1 lower compartment gas temperature. According to the MARCH predic-l tion (7) the discharge of liquid by the break flow into the lower com-partment lasts for only 2172 seconds. Afterward, the water level in the reactor vessel drops below the break elevation and the fluid discharged from the break is essentially steam. Therefore, in the present study, it is assumed that no fog is generated by the break flow after 2172
'I seconds.
i i
For fog removal by gravitational settling, a volume mean drop size of 10 a was assumed. The assumption of 10 a volume mean drop size is con-servative, considering the f act that for a few thousand seconds the drop agglomeration mechanism would be able to increase volume mean drop size substantially.
It should also be noted that a smaller volume mean drop size means that the minimum fog inerting concentration would be reduced and thus makes the present analysis conservative.
Furthemore, no con-I sideration was given to the deposition of fog on the walls and vertical surf aces of the structure, or for fog removal in the f an flows when it passes through ducts and fans. All the assumptions mentioned above make the present analysis very conservative. The containment geometric data needed in computing the settling rate are given in Table 6.8.
For fog removal by sprays, a spray flow rate of 6800 gpm was used for McGui re. According to the McGuire CLASIX analysis (28) the sprays are initiated at 124 seconds. A volume fraction of sprays (volume of sprays divided by volume of the spray zone) of 3.3 x 10-4 was used. As pre-viously discussed a spray removal efficiency of a 100 percent efficiency was used.
i In Figure 6.5, the directions of the intercompartmental flows are shown. The intercompartmental flow rates for the six flow paths and eight times steps were obtained from the CLASIX analysis and are given in Table 6.9.
The present analysis considers the interrompartmental flows as the mechanisms of transporting fog from one compartment to another.
0430Q:1/101882 v
,e-,-
m
,e,
Figure 6.5 shows two trains of the air return f an and hydrogen skimer system and the f an flow directions. The fans are initiated at 694 1
j seconds. The f an head-flow curve reported in Reference 28 was used to 3
l compute the fan flow rates. Fan flow rates of 1000 ft /sec and 100 l
ft /sec were used for the air return f an and the hydrogen skimer 3
j system, respectively. These flow rates were calculated using average I
ap's between the upper compartment and the lower compartment, and bet-l, ween the dead ended region and the upper compartment.
The results of the calculation are shown in Figure 6.8.
It is seen that for the first few hundred seconds the fog concentrations in the lower compartment, ice condenser lower and upper plenes are about the same and increasi ng. At about 600 seconds, the lower compartment volumetric 3
3 fog concentration reaches its peak of 1.6 x 10~4 ft H 0/ft 2
mi x. Afterward, the intercompartmental flows transport more fog droplets out of the lower compartment than are generated by the break flow and condensation and, therefore, the lower compartment fog concentration decreases. However, the upper plene fog concentration I
keeps rising until about 800 seconds, due to an increasing fog fonnation in the ice condenser and more fog entrained in the intercompartmental I
flow into the upper plene. The uyper pl~enum Tog concentration reaches its peak of 6.4 x 10-4 ft H 0/ft mix at about 800 seconds.
3 3
2 The lower plenum fog concentration is almost the same as the lower copartment fog concentration because of little difference in the intercompartmental flow rates into and out of the ice condenser lower f
pl enum. Therefore, these two volumes behave as a single volume in terms of fog concentration.
At 2172 seconds, the break flow in the lower compartment stops genera-ting fog and, therefore, the fog concentrations drop sharply there-after. The effect is more pronounced for the lower compartment and lower plenum fog concentrations. The highest fog concentration exists in the ice condenser upper piens while the lowest exists in the upper compartment. The effect of sprays on the upper compartment fog concen-tration is clearly seen in Figure 6.8.
At 124 seconds, the sprays are turned on and the upper compartment fog concentration drops sharply 6-27 04300:1/101882
~
v O'0009 J.,
c l
j j
e e
w f
CL. g o
t' F cQ D_
on uh tu r e
1 3
zv 0'0005 w
Iw r
e l,
l lI A O c
e air
'z ll 1
y c,
o e
m O
l
/
.i l
z e
t e
s 1 2, g "
/
2 u z 7
O j
w<
/
T 0'000t
- c. w e
ie O
u O
i f
,aw lu3 e
.=
es zo zj@
'?
[
] )(
i z-v
\\
7 3
'I-0'000E
.O
~k, T
l f
O
=
p
/
- 4 w
- 5
/
e
<. c.
M
__ j g
p
/ ::::g f
e c_ c_
-IO zO n c(
av::::
er u
y wue u
J-0'0002 w ze t
i e
Owr m
r 4
v2O i
Ieaw n/
.=-
w Oz s
I i O na n
=
s ju-a
//
s I
i 0'0001 Ni
- /
.:l
\\
b
<e d
s.
\\ /
N..7 N W h
ts o
gh
\\
)
n 00'001
,c n tn e new w e e~s ~~ ~
C 00 O O Cao O O C 00 O O O COO O O ONO M N ie i6 i ie i e
i a e e i i
e,c O c
-o ww W W ww ww wm w w y ONO m N o ao 000 00 00000 000 00 o
-ee C o C OO O. O C O O. O. O C.O.O O. O.
COO O. O C O. O. O O O
-~nmm
-~nmm
-~nmm
( X I N E **13 / 0 2 H E **13 ) NOI1V81N33N03 303 6-2C
=
.w.....
i until about 600 seconds. At about 600 seconds, the upper compartment l
fog concentration starts to increase again because the intercompart-I j
mental flow into the compartment increases sharply at that time. A peak concentration of 7.5 x 10-6 ft H 0/ft mix in the, upper compartment 3
3 2
i s reached at about 1500 seconds.
Hydrogen starts to release into the contairinent at about 3804 seconds, according to the MARCH calculationI20I.
It reaches 4 volume percent f
at about 4300, 4400, and 4850 seconds in the lower compartment, upper i
plentsn, and upper compartment, respectively.
At 4300 seconds, the calculated lower compartment fog concentration is 3
3 8.4 x 10-7 ft H 0/ft mix, which is about an order of magnitude 2
smaller than the minimum fog concentrations required for inerting 4 percent H. At 4850 seconds, the upper compartment fog concentration 2
i s 1.47 x 10-6 ft3 3
H 0/ft mix, which is about a f actor of five 2
smaller than the minimum fog concentration required for inerting 4 per-cent H *. At the times of reaching 8.5 percent H, the fog concen-2 2
trations in the lower and upper compartments are even lower than the figures given above. Therefore, it i s concluded that the fog concentra-tions in the lower and upper compartments 7rE 'too low to have any inerting effect. The use of the present theory on fog inerting also i
leads to the same conclusion.
However, at 4400 seconds, the calculated fog concentration in the upper 3
3 pl enum i s 9.8 x 10-5 ft H 0/ft mix which is higher than the 2
Factory Mutual fog inerting data extrapolated to 10 a drops and the j
present theoretical prediction. The data shows that in order to inert l
4.76 percent H the fog concentration must be 8.4 x 10-6 ft3 2
3 H 0/ft mix or higher for 10 a voltsne mean drop size. At 4500 2
seconds, the upper plenum hydrogen concentration reaches about 7 pertent and the fog concentration is 9.3 x 10-5 ft g 0/ft mix. Ag ai n, 3
3 2
1 i
The fog inerting criterion used is described in Section 5.2.
I i
6-29 l
04300:1/101982 t
l.,,. _ _
~.
I i
an extrapolation of the Factory Mutual data to 10 a shows that fog con-centration of 2.1 x 10-5 fg H 0/ft mix or higher is required 3
3 2
)
to inert 7.2 percent H.
In compari son, the present theory on fog 2
3 3
inerting predicts 1.02 x 10-4 ft g 0/ft mix for 7.2 percent 2
H, Therefore, it appears that it is possible to inert 7 percent i
2 I
H, but unli kely. However, at 8 percent H2 in the upper plenurn, 2
which occurs at about 4600 seconds, the fog concentration is 9.1 x 10-5 fg g 0/ft mix, which is too low to inert 8 percent H
- 3 3
2 2
l An extrapolation of the Factory Mutual 8 percent H2 data to 10 u volume mean drop size and the present prediction give 1.9 x 10~4 and 1.2 x 1C-4 ft3 3
H 0/ft mix for the minimum required fog inerting 2
l concentration, respectively. Therefore, both the theory and the extra-polation of the test data indicate that fog inerting will not occur, i
The glow plug igniters which have been installed in the McGuire contain-ment were designed to burn hydrogen at the lower flammability limit. As discussed previously, no fog inerting effects will be expected in '.he j
McGuire lower and upper compartments. Therefore, the glow plug igniters are expected to function as designed in these two compartments.
It may i
be possible that fog present in the ice condenser upper plenum could I
prevent the glow plug igniters froni igniti'ng~hy3rogen below-7 percent.
However, it seems very unlikely that the same igniters would f ail to ignite 8.5 percent H2 given the f act that considerable conservatism has been exercised in the present analysis. Cl.ASIX analyses have previously been perfomed that showed the McGuire containment response to burning 8.5 percent H2 mixtures would be acceptable.
6-30 04300:1/101982
_ ~.. -
TABLE 6.6 INPUT DATA FOR McGUIRE LO'4R COMPARTMENT i
Steam l
Lower Compartment Gas Wall Total Parti al Gas Flow Rate Temp.
Temp.
Pressure Pressure 3
~
Time (sec)
(ft /sec)
(*F)
(*F)
(psia)
(psi a) 60 1624.6 160 149 16.5 7
510 1248.1 225 215 22.2 18.3 j
1510 2387.8 205 198 21.9 12.6 2010 2393.8 205 198 22 12.4 2510 1940.7 195 193 21.5 10.4 3260 2055.5 200 195 21.6 10.8 3760 1801.7 200 194 21 9.3 4510 1919.3 250 222 21.2 7.3 i
i e
m ee M e 6 e
e wwo.=
1 1
l i
l 6-31 04300: 1/101982
[
- -a -
TABLE 6.7 INPUT DATA FOR McGUIRE ICE CONDENSER l
Steam Ice Condenser Gas Ice Total Parti al Gas Flow Rate Temp.
Temp.
Pressure Pressure 3
Time (sec)
(ft /sec)
(*F)
(*F)
(psi a)
(psi a) 60 820.5 90 32 16.5 1
510 107.1 130 32 22.2 2.3 1510 1926 190 32 21.9 9.3 2010 1637 193 32 22 9
2510 1145 188 32 21.4 8.5 3260 1630 195 32 21.6 10.3 3760 1514 193 32 21.1 8.1 4510 1464 192 32 22.1 7.1 I
i 1
}
4 I
6-32 0430Q: 1/101982
TABLE 6.8 GE0lETRIC DATA FOR McGUIRE CONTAINMENT i
3 2
Volune (ft )
Floor Area (ft )
Lower Compartment 237,400 5,410 o
Ice Condenser Lower Plenun 24,200 3,100 Ice Condenser Upper Plenun 47,000 3,200 Upper Compartment 670,000 10,390 Dead Ended Region 130,900 3,350 i
n-33 l
04300:1/101982 "P-
-"P y
w e-m,y
.%.-i
3 TABLE 6.9 INTERCOMPARTMENTAL FLOW RATES (ft /sec) i I
PREDICTED BY CLASIX FOR McGUIRE j
Time Flow From Flow From Flow From Flow From Flow From (sec)
LC to LP LP to UP UP to UC UC to LC DE to LC 6.001El 1.351E 3 8.205E 2 5.783E2
-1.19E 2
-1.53E 2 5.10E2 8.716E2 1.071E2
-2.269El
-2. 863E 1
-3.479E 2 1.510E 3 2.008E 3 1.92E 3 8.635E2
-1.90E 2
-1.898E 2 2.010E3
- 2. 01E 3 1.637E3 6.869E2
-2.266E2
-1.572E 2
- 2. 510E 3 1.722E3 1.145E 3 4.807E2
-1.410E 2
-7.767E l 3.26E3
- 1. 713E 3 1.63E3 6.666E 2
-2. 087E 2
-1.338E2 3.76E 3 1.54E 3 1.514E3 7.231E2
-1. 289E 2
-1.26E 2 l
4.510E3 1.634E 3 1.464E3 7.640E2
-1.328E2
-1. 515E 2 1
i l'
m
.-a=
e -ee l
t 6-34 0430Q: 1/101982
f 6.4 F0G INERTING PROBABILITY IN THE 0. C. COOK PLANT To compute the fog fomation rates some output data from the Cook CLASIX analysis (29) are needed. These data include time histories of gas temperature, wall temperature, total pressure, and steam partial pres-sure in each containment subcompartment, as well as the intercompartmen-tal and fan flow rates. The subcompartmentalization model used in the Cook CLASIX analysis is shown in Figure 6.9.
In this study only the S 0 accident scenario has been analyzed.
2 The input data for Cook S D Case 1 are given in Tables 6.10 and 6.11, 2
and the calculational results are shown in Figures 6.10 and 6.11.
In Figure 6.10, the fog fomation rate in the lower compartment is shown.
It is seen that the fog fomation rate is negligibly small.
It should l
be noted that the calculation of the lower compartment fog concentration I
i in the D. C. Cook plant starts at 600 seconds instead of 60 seconds used for the other two plants. The fog fomation rate in the lower compart-memt starts to increase at about 4200 seconds because of the increase in
{
the steam partial pressure.
It reaches 0.017 lb/sec at about 4590 seconds. Fog fomation in the lower compartment will stop after 4700 i
seconds because of the hydrogen burn ther~eafteK The fog f6rmation rate in the ice condenser is shown in Figure 6.11.
It is seen that the fog I
formation rate in the ice condenser is much larger than that in the lower compartment.
It increases with the ice condenser steam flow rate and reaches a peak of about 15.6 lb/sec at about 1200 seconds. The fog formation rate in the ice condenser then begins to decrease and is low at the time of significant hydrogen release.
The input data needed to calculate the rate of fog generation by the break flow, the fog settling rate due to gravity, and the fog removal rate due to sprays, as well as the rates of fog entrainment by inter-compartmental and f an flows are discussed as follows.
The rate of reactor coolant release to the containment and the coolant enthalpy were obtained from the MARCH output (7) for a small LOCA. The 6-35 04300:1/101982
%a y
y---- - - + - - -
w u-.-
c
l t
'l FIGURE 6.9 D.C. COOK CLASIX MODEL rrrrrs
'l ICE CONDENSER I
UPPER
- - - +
UPPER l
COMPARTMENT
{
PLENUM I
l A
A l
ti i
ICE BED i
Y Y
j l
l ICE i
l CONDENSER LOWER LO COMPARMEM l
l PLENUM i
I a
l A
A j
i s
l l
i Y
i V
a' DEAD
+
FAN /
ENDED ACCUMULATOR REGION ROOMS l
i A
i i
O l
i AIR RETURN FAN / HYDROGEN SK1MMER SYSTEM l
FLOW PATH CONTAINS DOORS I
4 FLOW ALLOWED IN BOTH O! RECT 10NS FLOW ALLOWED IN ONE DIRECTION SPRAY HEADER
............rz i
C-20 m
w-,
l..
4 O'0009 i
I i
l l
a mx I
t c
2 2
O ' 000 ti zo U
e L
2 O
a s
0'000F ou k
1 W
C
~
J Z
2 0'0002 C h
i
.c u
w O
u 1
e j
O'0001 ~
0*O a
o e
e e
e e
e C
10 C
O C
C C
c e
en cn m
m a
C O
O O
O O
O O
O e
o e
o o
e o
o a
(33S/81) 31V 8 N 011V W 8 03 903 6-37
1 0*0005
/
1 1
i
=
I w
i C
~
0'000#
/
wa=
C v
w a
h l
O*000E o
Cv 4
i t
W w
x
~D j
g
=_
/
t 3
0*0002
/
w
^
4 U
t t
2 w
2 M
C w
w I
Q w
m 0 0001 -
l N
N N
0*0 O
C C
C C
C C
c C
C O
C O
C o
o C.
C.
C.
C O
O O.
W D.
o.
p o.
C N
N Oe
=
==
k p
m o
m (33S/87) 31VB N 011V H 803 003 G-38
--e
+
=
-... ~..
. - ~..... -....
quality of the break flow was calculated using the enthalpy and the lower compartment gas temperature. According tc, the MARCH predic-l tion (7) the discharge of liquid by the break flow into the lower com-4 partment la',ts for only 2172 seconds. Afterward, the water level in the reactor vessel drops below the break elevation and the fluid discharged from the break is essentially steam. Therefore, in the present study, it is assimed that no fog is generated by the break flow after 2172
-J seconds.
3' 4
./
' For fog removal p, gravitatkonal settling, a volume mean drop size of 10'u tesrsi;sumed. The,aystaption of 10 a volume mean drop size i s con-y c
servative, cogiering tile f act that for a few thousand seconds the drop s
'~
agglomeration mechanisrc would be able to increase volume mean drop size substanti ally.
It should :aiso be noted that a smaller voltne mean drop size means that the minimta [og -inerting concentration would be reduced and thus makes the prescet analysis even cre tonservative. Further-more, no consideration'Was given to the: deposition of fog on the walls i
and vertical surfaces of the structu e, or fo'r fqi removal in the f an,
flowy when it passes through ducts and fans. All the assumption & men-tioned above make the present analjsis very conservative. The contair1; ment geometric data needed in cG3puting the settling rate are given jnj l
Table 6.12.
, s 4000, 1800, and 5_28 gpm For fog removal by sprays, spray flow rates of were used for the upper compartment, lower compartment, and fan /accumu,
s I ator rooms, respectively. According to the Cook CLASIX anal'fhj J 29) the sprays are initiated at 141 seconds. A volume fraction, of SDrays (volume of sprays divided by voline of the spray zone) of 3.3 x' 1b-4 was used. As previously discussed a spray removal efficiehcy of a 100 percent efficiercy was used.
p.. +
~.
7 3
4 In Figure' 6.9, the directions of the intercompartmental flows are shown. 'The intercompartmental f13w' rates for the six flow paths and
~
s eight time steps were obtained from the CLASIX analysis and afe.given in l
\\
N 4
s f.-39 \\
r 0430Q:1/1019fj2
\\
i
%... 3 y-
l Table 6.13. The present analysis considers the intercompartmental flows as the mechanisms of transporting fog frcm one compartment to another.
Figure 6.9 shows two trains of the air return f an and hydrogen skimmer system and the f an flow directions. The fans are initiated at 711 seconds. The f an head-flow curve reported in Reference 29 was used to compute the fan flow rates. Fan flow rates of 1388, 61.76, and 4.13 3
ft /sec were used for the flows from the upper compartment, lower compartment, and dead ended region to the fan / accumulator rooms, respecti vely. These flow rates were calculated using the ap's between the the fan / accumulator rooms and three other compartments.
The results of the calculation are shown in Figure 6.12.
It is seen that for the first few hundred seconds the fog concentrations in the i
lower compartment, and the ice condenser lower plenum are high. At i
about 140 seconds, the lower compartment volumetric fog concentration 3
reaches its peak of 1 x 10-4 ft 3
H 0/ft mix. Af ter the sprays 2
are initiated at 141 seconds, the fog concentrations in the lower com-j partment, upper compartment, and fan / accunulator rooms drop sharply.
However, the upper plenun fog concentration keeps rising until about 1200 seconds, due to an increasing 70g forfaatioil in the ice condenser and more fog entrained in the intercompartmental flow into the upper pl enun. The upper plenum fog concentration reaches its peak of 2.4 x i
10-4 ft3 g 0/ft3 mix at about 1200 seconds. After about 1200 2
seconds, the lower plenun fog concentration is almost the same as the lower copartment fog concentration since the intercompartmental flows quickly make the fog concentrations in these two compartments unifom.
Therefore, these two volumes behave as a single volune in terns of fog concentration.
At 2172 seconds, the break flow in the lower compartment stops genera-ting fog and, therefore, the fog concentrations drop sharply there-after. The effect is more pronounced for the lower compartment and lower plenum fog concentrations. The highest fog concentration exists in the ice condenser upper plenum. The effect of sprays on the upper 6-40 04300:1/101982
._..2.__.._..
0'0009
\\
\\ \\
v.,
1 I
.i >
g i
e y
o i l u
e a >
s o
zc o
u >
<-ii i
2 u
z e
a>
<- i u
zw w '-.a 4
c-2 0'0005 I
l I
al z
u o
mi z a: <
l W6
<.t m/
.I
.}r j
a :
4
- c. ii
- c. W 9
e l,,i
- I lp h
}
f z
oDsi z 4,
e o
- n a
J:
I mo I.c 1
l l
0'0004 z u i
(
i O 3 W c'l ol i
i a
- p z C:
l
.W c1l Ldl
.i{'
(C fs u
O
' > c'. z I
I d
c.,
e e
I w
c:
c-I c.b' e
u es
- we t
0'000E 1
ow 1
1
~
zJC 5
.q-O rs Il 11 g
y:n eu u'
' s m
c.
t e
p I
8 cx:
3 u) 9 p
Js 8
c: c. c.
-II e
un o::pe 1 o C>
j-
- {
~
0'0002 v wuu 2
I v
ll w
sJ z c: c:
er wa m
m QwW l
l
~
u c.
- r waso a >
w o c-l l
uam ras a3 z
O fl Il l
s.,'
g u
ir n
f, l
(
l t
( :
0'0001 k-3 N
lp.'-
g
\\
w
,b
..,5 i
t s
.f li; u>
1J e
O*O
.=rv,vv, vuou:m e~ - -c:co emnc c3 en C"lllZ3CXl3 CCDCC, CCCDCC CCCCCD C:Z3CC,3 Q
>>> ii iiii iiiiiiiiiiiiii i
C=e CC cm <ma Cmem;-CeCC -iu.aw.aam w w w - w - m w 6 CC CC"O CC C:'"c"3 CCD C:"I3 CC CCZ"3 CC CT CCD C: g) cc) o C.CD.CC. C.C.D.C.C. C.CD.CC. NCC. C.CCC.C CCC.CC C: ;c.)CC o c=e Ce c=o cQ e meu --+-v,ema
--+-v,.reru %cm; -- -y,nru -
( X I W E **.L:! / 0 2 H E **13 ) N0I1YB1N 33N0 3 003 6-41
-... - -. -.. ~.. -
t compartment fog concentration is clearly seen in Figure 6.12. At 141 seconds, the sprays are turned on and the upper compartment fog concen-f tration drops sharply until about 300 seconds. At about 300 seconds, the upper compartment fog concentration starts to increase again because the intercompartmental flow into the compartment increases sharply at that time. A peak concentration of 9.5 x 10-6 ft3 H2 /ft3 mix 0
in the upper compartment is reached at about 1400 seconds.
Hydrogen starts to release into the containment at about 3804 seconds, according to the l%RCH calculation (29).
It reaches 4 volume percent at about 4350, 4370, and 4700 seconds in the lower compartment, upper plenum, and upper compartment, respectively.
At 4350 seconds, the calculated lower compartment fog concentration is l
10-7 ft3 3
H 0/ft mix, which is about two orders of magnitude 2
smaller than the minimum fog concentrations required for inerting 4 percent H. At 4700 seconds, the upper compartment fog concentration 2
i s 2.4 x 10-6 ft3 H20/ft mix, which is about a f actor of two 3
i smaller than the minimum fog concentration required for inerting 4 per-cent H
- j 2
At the times of reaching 8.0 percent H, the fog concen-2 l
trations in the lower and upper coliipartme'n'ts'a're even lower than the
~
figures given above. Therefore, it is concluded that the fog concentra-tions in the lower and upper compavanents are too low to have any iner-i ting effect. The use of the present theory on fog inerting also leads
- o the same conclusion.
I However, at 4370 seconds, the calculated fog concentration in the upper pl enum i s 6. 5 x 10-5 ft3 H 0/ft mix which is higher than the 3
2 Factory Mutual fog inerting data extrapolated to 10 u drops and the present theoretical prediction. The data shows that in order to inert the fog concentration must be 8.4 x 10-6 ft3 4.76 percent H2 3
H 0/ft mix or higher for 10 a volune mean drop size. At 4530 2
seconds, the upper plenum hydrogen concentration The fog inerting criterion used is described in Section 5.2.
04300:1/101982 6-42 r - -----
f---
W
- - - - - - ~ - " ' - - - ' " - - ' - - -
reaches about 7 percent and the fog concentration is 5.5 x 10-5 fg3 3
H 0/ft mix. Again, an extrapolation of the Factory Mutual data to 2
10 a shows that fog concentration of 2.1 x 10-5 fg3 3
H 0/ft mix 2
or higher is required to inert 7.2 percent H.
In comparison the 2
3 3
present theory of fog inerting predicts 1.02 x 10~4 ft H 0/ft 2
mix for 7.2 percent H. Therefore, it appears that it is possible to 2
inert 7 percent H, but unlikely. However, at 8 percent H2 in the 2
upper plenum, which occurs at about 4600 seconds, the fog concentration 3
3 i s 5.1 x 10-5 ft H 0/ft mix, which is too low to inert 8 2
percent H. An extrapolation of the Factory Mutual 8 percent H2 2
data to 10 a volume mean drop size and the present prediction give 1.9 x 3
3 10~4 and 1.2 x 10~4 ft g 0/ft mix for the minimum required 2
fog inerting concentration, respectively.
The glow plug igniters which have been installed in the Cook containment were designed to burn hydrogen at the lower flammability limit. As discussed previously, no fog inerting effects will be expected in the Cook lower and upper compartments. Therefore, the glow plug igniters are expected to fun: tion as designed in these two compartments.
It may be possible that fog present in the ice condenser upper plenum could prevent the glow plug igniters froM ignitTng h drogen below-7 percent.
y However, it seems very unlikely that the same igniters would fail to ignite 8 percent H2 given the f act that considerable conservatism has been exercised in the present analysis. CLASIX analyses have previously l
been performed that showed the Cook containment resoonse to burning 8.0 i
percent H2 mixtures would be acceptable.
i 6-43 04300:1/101982 i
=
f TA8LE 6.10 INPUT DATA FOR 0. C. COOK LOWER COMPARTMENT
,l Steam Lower Compartment Gas Wall T9tal Parti al l
Gas Flow Rate Temp.
T emp.
r'ressure Pressure 3
(ft /sec)
(*F)
(*F)
(psia)
(p si a) l Time (sec) 600 799.4 222 215.2 21.8 17.4 1200 2798.2 190 183.5 20.2 9.4 1800 2805.8 190 180.3 20 9.1 2400 2513.6 180 177.2 19.6 7.6 4
i 3000 2448.5 178 170.4 19.3 7.2 3600 2359.7 175 169.3 19.2 6.4 3
j 4200 2272.3 165 161.9 18.8 5.3 l
4590 2482.7 168 161 19.5 5.8
'i i
1 9
6-44 04300: 1/101982
~****==e a
-we m,--
-,,,c
i i
TABLE 6.11 INPUT DATA FOR 0. C. COOK ICE CONDENSER 1
Steam Ice Condenser Gas Ice Total Parti al Gas Flow Rate Temp.
Temp.
Pressure Pressure 3
Time (sec)
(ft /sec)
(*F)
(*F)
(psia)
(psia) 600 76 147 32 21.8 3.4 1200 2548 190 32 20.1 9.3 1800 2572 188 32 19.9 9.0 2400 2359 184 32 19.7 7.9 3000 2256 187 32 19.3 7.1 3600 2199 175 32 19.2 6.6 4200 2126 166 32 18.8 5.3 4590 2312 163 32 19.8 4.3 t
{
1 4
6 45 04300: 1/101982
~
- - ~
m
- - _ - -, -,, -,, +
j TABLE 6.12 GE0lETRIC OATA FOR 0. C. COOK CONTAINMENT I
3 2
Voltne (ft )
Floor Area (ft )
Lower Compartment 249,681 5,410
{
Ice Condenser
{
Lower Plenta 24,700 3,100 Ice Condenser Upper Plenta 47,010 3,200 Upper Compartment 681,283 10,390 Dead Ended Region 61,105 853 Fan / Accumulator Rooms 54,828 2,500 l
l 1
r i
6-a6 04300: 1/101982 w,
o,-
---m----m---
v-a
3 l
TABLE 6.13 INTERCOMPARTENTAL FLOW RATES (ft /sec)
PREDICTED BY CLASIX FOR D. C. COOK Time Flow From Flow From Flow From Flow From Flow From Flow From (sec)
LC to LP LP to UP UP to UC UC to LC DE to g F/A to LC 600 6.387E2 7.60E1
-4.410E1
-3.746El
-1. 232E 2
-1.229E 2 1200 2.577E3 2.548E3 1.106E3
-1.740E 2
-4.720E1 1.509E3 1800 2.60E3 2.572E 3 1.155E3
-1.62E 2
-4.381E l 1.529E 3 2400 2.356E3 2.359E3 1.145E3
-1.325E 2
-2.512E1 1.595E3 3000 2.273E3 2.256E 3 1.178E3
-1. 463E 2
-2.923E 1 1.553E3 3600 2.202E 3 2.199E3
.. 190E 3
- 1.334E 2
-2.333E1 1.603E3 4200 2.13E 3 2.126E3 1.25E 3
-1.183E 2
-1.802E1 1.642E 3 4590 2.346E 3 2.312E3 1.400E 3
-1.130E 2
-2.371El 1.650E3 i
h i
I e
6-47 04300:1/101982
4 l
7.0 SLNMARY AND CONCLUSIONS The present study has developed a systematic methodology to study the d
'I potential fog inertirg problem for the PWR ice condenser plants. In the present investigation, major fog fonnation and removal mechanisms are i
'e j
identified and quantified. Theoretical models are developed to predict 1
the fog fonnation rate due to boundary layer and bulk stream condensa-i lI tion, the fog removal rates due to gravitational settling and contain-I ment sprays. The mass conservation equations for the fog droplets in
)
each of the containment subcompertments are solved simultaneously in order to obtain time histories of fog concentration. These equations
{
incorporate fog fonnation due to condensation, fog generation due to j
l breck flow, fog removal due to gravitational settling and sprays, trans-l port of fog by the intercompartmental flows and f an flows. These I
I equations have been used to analyze an S D accident sequence for the j
2 Sequoyah, McGuire, and D.C. Cook plants. The analyses employed output 9
I data from the respective CLASIX analyses. Specifically, time histories i
j of gas temperature, wall temperature, total pressure, and steam partial pressure in each containment subcompartment, as well as the intercom-partmental and fan flow rates were used in the present analysis.
j l
A fog inerting criterion has been developed to predict the ministan fog i
i 4
I concentration for a particular voltane mean fog drop size required to inert a given hydrogen concentration. The present fog inerting criterion has been shown to be in general agreement with the Factor /
Mutual data. The criterion shows that the minimum fog inerting concen-I tration varies with the square of the voltane mean fog drop size.
1 The present study shows that the fog concentrations in the upper and lower compartments of the three plants analyzed are too low to have any inerting effect on hydrogen mixtures. Therefore, the glow plug igniters are expected to function as designed in these two compartments.
It may be possible that fog present in the ice condenser upper plenum could 71 04300:1/101982
- y-,-
---v,-
y
--rr y--yw w
w ww---
ww--
y
-w-
-r
-y n
=-
prevent the glow plug igniters from igniting hydrogen below 7 percent.
However, it seems very unlikely that the same igniters would fail to ignite 8-8,5 percent H, given the fact that considerable conservatism 2
j has been exercised in the present anlysis. CLASIX analyses have l
previously been performed that showed the containment responses to i
burning 8.0-8.5 percent H2 mixtures would be acceptable.
I I
t I
i i
1 04300:1/101982
__m_m_.--
l i
i ACKNOWLEDGMENTS The auta..* w h e, to express his sincere gratitude to Mr. N.J. Liparulo, Drs. V. Sri B. Lewis, and B. Karlovitz for assistance, sugges-tions, anc hitipt.I discussions, particularly in the area of the fog inerting c'iteria Tnd the flame temperature criteria for fog, to Messrs.
/. ', eford, R. Bryan, F. G. Hudson, and K. Shiu for valuable :ccraert.
to Mr. K. C. Perry, Mr. S. J. Reiser, and j
Ms. R. M. P.arfr.er hr oroviding data on the three ice condenser plants, and to Mr. T. J. Miele for pm!! ding programing assistance.
He also would like to t,'ank 1YA, L !ke 'ower, and AEP for providing the financial support.
t
/
h I
I i
j 0430Q:1 7-3 i
- " ~..
"Y
I 4
i REFERENCES 1.
B. Lowry, " Preliminary Results: A Study of Hydrogen Igniters,"
j l
ENN80-45, Lawrence Livermore National Laboratory, November 17, 1980.
i 2.
" Additional Questions on Hydrogen Control SyJtem for Ice Condenser Plants," NRC memo from L. Rubenstein to R. Tedesco, dated June 26, 1981.
3.
"The Marvikken Full Scale Containment Experiments," MXB-301 AB Atomenergi, March,1977.
4.
T. F. Kanzleiter, "LOCA Experiments With a PWR Multi-Compartment Model Containment," Trans.1977 LWR Safety Conf., Idaho Falls, Id aho, 1977.
5.
G. M. Fuls, "The CLASIX Computer Program for the Hydrogen Release and Degradation", OPS-07A35, Offshore Power Systems,1981.
t 6.
K. K. Almenas, "The Physical State of Post-Loss-of-Coolant Accident Containment Atmospheres," Vol. 44, Nuclear Technology, pp. 411-427, August, 1979.
I 7.
" Summary of Analysis of Ice Condenser Containment Response to Hydro-gen Transients," Offshore Power Systems report No. RP-2BA52, Septem-ber, 1980.
8.
R. Brown and J. L. York, " Sprays Formed by Flashing Li quid Jets,"
Vol. 8, No. 2, AICh.E Journal, p.149, May,1962.
9.
R. G. Gido, and A. Koestel, "LOCA-Generated Drop Size Prediction - A j
Thermal Framentation Model," Trans. Am. Nucl. Soc., 30, p. 371,1978.
- 10. P. G. Hill, H. Witting, and E. P. Demetri, " Condensation of Metal Vapors During Rapid Expansion," Journal of Heat Transfer, p. 303, November, 1963.
"I 0430Q:1/101982
..~-...._
i
- 11. M. Volmer and H. Flood, Z. Physik Chemie, A170, p. 273,1934.
l
- 12. C. E. Junge, Advan. Geophys., H. Landsberg and J. Van Mieghem, ed.,
4.1, Academic Press, New York,1958.
- 13. K. Almenas, and J. Marchello, "On the Creaction and Persistence of Mist-Laden Post-LOCA Containment Atmospheres," Trans. Am. Nucl.
Soc., 30, P. 370,1978.
- 14. R. K. Hilliard and L. F. Coleman, " Natural Transport Effects on Fission Product Behavior in the Containment Systems Experiment,"
BNWL-7457 Battelle-Northwest, Richland, Washington,1970.
I
- 15. N. H. Fletcher, J. Chem. Phys., 29, p. 572; 31, p.1136,1958.
i
- 16. D. E. Rosner and M. Epstein, " Fog Formation Conditions Near Cold Surfaces," Vol. 28, No.1, J. of Colloid and Interf ace Sci., Septem-ber, 1968.
- 17. K. Hijikata, and Y. Mori, " Forced Convective Heat Transfer of a Gas With Condensing Vapor Around a Flat P1 ate,'" Vol. 2, No.1, Heat
~
~
~
~
Transfer - Jap. Res., pp.81-101, January,1973.
j
- 18. M. Nef burger and C. W. Chien, " Computation of the Growth of Cloud Drops by Condensation Using an Electronic Digital Computer,"
Geophys. Monograph No. 5, pp.191-209,1960.
- 19. R. M. Kemper, " Iodine Removal by Spray in the Salem Station Contain-ment," WCAP-7952, Westi nghouse Electric Corp., August,1972.
- 20. N. J. Liparulo, J. E. 01hoeft and D. F. Paddleford, " Glow Plug Ignitor Tests in H2 Mixtures," WCAP-5909, Westinghouse Electric Corp., March 6,1981.
- 21. R. G. Zalosh and S. N. Bajpai, " Water Fog Inerting of Hydrogen - Air Mixtures," EPRI Project Preliminary Rp.1932-1, September,1981.
0430Q:1/101982 R-2 en
i
- 22. J. M. Marchello, " Control of Air Pollution Source," Marcel Dekker, Inc., New York,1976.
- 23. Letter from B. Lewis and B. Karlovitz to L. E. Hochreiter, dated may 5, 1930.
l
- 24. M. Bennan, et al., " Analysis of Hydrogen Mitigation for Degraded j
Core Accidents in the Sequoyah Nuclear Power Plant," Sandia draft report, December 1,1980.
- 25. T. von Karman, Unpublished notes,1956.
- 26. S. S. Tsai, "Flaae Temperature Criteri a Tests," NS-CCA-81-039, West-inghouse internal memo, dated June 17, 1981.
l
- 27. Attachment to Offshore Power System letter PST-NE-109, dated May 22, f
1981.
- 28. Attachnent to Offshore Power System letter P5T-NE-106, dated May 14, j
1981.
t i
- 29. Attachment to Offshore Power System letter PST-NE-218, dated August 6, 1981.
4
- 30. M. L. Corri n, J. R. Connel, and A. J. Gero, "An Assessment of Warm Fog - Nucleation, Control, and Recommended Research," MASACR-2477, November, 1974.
l l
l R-3 l
04300:1/101982 l
l APPENDIX A I
COMPUTATION OF Y AND ( IN EQUATION (3.12) g I17I The Hijikata-Mori fog for nation theory used the boundary layer approximation for the continuity, momentun, and energy equations. The fog concentration and velocity profiles in the boundary layer are assuned in Eqs. (3.7) and (3.8). Substituting Eqs. (3.7) through (3.10) into the conservation equations, we have 1
+
g+
Y + v'
=0 (A-1) o
-(1+Y)[V -d+
+ d g Y, + v'
=0 (A-2) g+
V g
-f(1+g)h (A-3) d+ d g +
Y + v'
=
g j
A (n) + B (n) g + f C (n) + h E Y,
= h { [ - V, - Vg (1 + E) Y (A-4) g i
i
~
- - ' ~ ~
where A (n) = 4 (n + 1) (n + 3) (n + 4) 3 (n + 6) 8 I"I
- 4 in + z) (n + 3) (n + 4) 3 (n + 7)
C ( n ) = 4 ( n +.1 ) (n + d) in + b)
'N V
=
=
1-W 2 AW y
o (1 - W )5 g g h
9 E
=C af pg i
e' A-1 0430Q:1/101982
=
2 a
U, v
ay v'
=
a U,
=
1 W
weight fraction of vapor at free stream
=
W weight fraction of vapor at wall
=
o 3
AW W, - W,
=
1 S
Schmidt number
=
c kinetic viscosity v
=
i v,
component of the free stream velocity perpendicular to
=
the wall h
heat of vaporization
=
j yg j
C specific heat of non-condensible gas
=
pg aT T, - T
=
o T.
gas temperature at free stream
=
T gas temperature at wall
=
o Equations (A-1) through (A-4) are four algebraic equatione for four unknowns, Yo,(, R, and v'. These equations have been solved by the computer program FOG. In FOG, the values of Y, C, and R are o
computed and used in Eq. (3.12) to compute the fog fonnation rate.
i i
l I
}
t I
A-2 0430Q:1/101982
- m..
APPENDIX B j
DERIVATION OF EQUATION (5.5)
This appendix gives detailed procedures to derive Eq. (5.5), starting f rom E q. (5.4) 1 = f ( (Y - Y )/e )
(5.4)
(K)cMt 8 u
f g
I where the ratio of heat loss rate per unit volume to the heat release rate by chemical reaction per unit volume, (K)cMt, is defined as l
XcMt = S/C w (B-1) p and the ratio of sensible heat to heat of combustion, e, is defined as j
g=Cp (Tj - T )/q (B-2) o u
l To arrive at Eq. (5.5), it is necesary to assume that all the heat loss is attributed to convection heat transfer to fog droplets of only one drop size. Under this assunption,_the rate of teat loss per unit volume per degree, S, may be expressed as 2
S = nud h e
number of drops per unit volume where n
=
volume mean drop size d
=
heat transfer coefficient h
=
It i s further assumed that the relative velocity between the droplets and the mixture flow is so small that heat transfer coefficient, h, c an be approximated by the conduction limit. Under thi s assumption, E q.
(B-3) reduces to S = 12ni (B-4) d 04300:1/101982
....-.......-u..
mean heat conductivitL-where x
=
3 voltsne fraction of mist droplets (h a d )
=
n The rate of heat generation per unit volume, w, is related to he laminar burning velocity, S, and the thickness of the reaction zone, f.,
by u
2 o Su (Y -Y) u u
f w=
(B-5) g j
The thickness of the reaction zone may be approximated by I
A=
(B-6)
S S u u p Combi ning Eqs. (B-1), (B-4), (B-5), and (B-6), we have 12ni (B-7)
K
=
crit 4
4g4 (Y -Y)d#
3
,u u
p u
f Substituting Eqs. (B-2) and (B-7) into Eq. (5.4), we have a
I i
qC o
S Y
-Y l
(y", y ) f ( u f)
(5.5) p u u
d 12 i # (T4-TI
'I u
j Q.E.D.
I i
t t
4
~
0430Q: 1/101982
=.
.w..
--w%
, _ _,