ML20009F066

From kanterella
Jump to navigation Jump to search
Discusses Applicability of Tech Spec Tables 3.1.1 & Tech Spec 3/4.10.A,core Alterations & Refueling Interlocks,In Licensee Proposal Re Mod to Scram Discharge Vol Sys & Reloading Fuel.Tech Spec Change Unnecessary
ML20009F066
Person / Time
Site: Peach Bottom Constellation icon.png
Issue date: 07/21/1981
From: Fairtile M
Office of Nuclear Reactor Regulation
To: Cowgill C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 8107280656
Download: ML20009F066 (1)


Text

1 i

.D

'RY 2 1 1991 %

wr,t

%my

,p.,

w cp y

y-

>;.f g

Q

, w s

//

/

+.

DISTRIRUTION:

HRCL PDRI N

\\

!h%

Cnnekot FTfh

'0RBf4'Rdg July 21, 1981 Oh L PDR Memo File MFairtile C. k Docket No. 50-278 4

6 ;,4.*'

f,..--

q 4

MEMORAllDUM FOR: Curtis Cowgill, Sr. Resident Inspector, Peach Bottom Station i

FR0ft:

Morton B. Fairtile, Project Manager, Operating Reactors, i

Branch #4, Division of Licensing

)

SUBJECT:

APPLICABILITY OF TECll SPEC TABLE 3.1.1 AND TECH SPEC 3/4.10.A. WHILE CONTROL RODS ARE BLOCKED IN CORE The licensee is currently modifying the Scram Discharge Volume System and reloading fuel in the Peach Bottom Unit 3 core.

In the Tech Specs, Footnote 2 to Table 3.1.1 permits bypassing the "lligh Water Level in Scram Discharge Volume" Trip Function while the reactor mode switch is in the

" refuel" or " shutdown" position. Thus, the Tech Specs clearly permit omis-sion of this trip function test as the mode switch is in the " refuel" position.

Tech Spec 3/4.10.A-Core Alterations - Refueling Interlocks., states-in the j

bases section, "The interlocks prevent an inadvertent criticality during refueling operations when the reactivity potential of the core is being i

altered." This Tech Spec calls for designated interlock tests at specified intervals; however, since the control rods are blocked against any motion, the blocking is equivalent to meeting the intent of the bases statement quoted above.

In consideration of the above there is no need for a Tech Spec change.

i Original signed by I

fjorton B. Fairtile, Project Manager Operating Reactors Branch #4 Division of Licensing cc:

DEisenhut i

TNovak JStolz J

l 81072806S6 810721 PDR ADOCK 05000278 P

PDR o,,,c,p!

ORB #4 :DL

.......r i e/I:E fiFai

!.uns.ur)

.... / y /.81 7

osu )

~.....

i nne.onu mom soycu e2it

__OFFICI AL RECOR D COPY s usc.m im_32,.:.j