ML20003C494

From kanterella
Jump to navigation Jump to search
Advises That Review of Potential Problems W/Surveillance Procedures & Multiple Failures Is Resolved
ML20003C494
Person / Time
Site: Yankee Rowe
Issue date: 01/28/1981
From: Crutchfield D
Office of Nuclear Reactor Regulation
To: Kay J
YANKEE ATOMIC ELECTRIC CO.
References
NUDOCS 8103060275
Download: ML20003C494 (2)


Text

-

--- - g a mecy

.-~

e

'o d

< UNITED STATED

[\\,i "q* /(',j NUCLEAR REGULATORY COMMISSION C

WASHINGTON, D. C. 20S55 k N4[ #

DISTRIBUTION CDocket NSIC

~NRC PDR TERA

~

Docket No. 50-29 Local PDR ACRS (16)

ORB Reading Deisenhut b ' / Id 8" " /

RPurple TNovak Mr. James A. Kay Rtedesco Senior Engineer-Licensing Glainas Yankee Atomic Electric Company DCrutch fiel d 1671 Worcester Road HSmith Framingham, Massachusetts 01701 RCaruso 0I&E (3)

Dear Mr. Kay:

0 ELD

SUBJECT:

REVIEW 0F POTENTIAL PROBLEMS WITH SURVEILLANCE PROCEDURES AND MULTIPLE FAILURES We have reviewed your letter of September 28, 1979 concerning inadvertent safety injection during surveillance testing at Yankee-Rowe.

We find that your response adequately addresses the concerns stated in our September 21, 1979 letter (which enclosed our June 26, 1979 letter) f and, therefore, we consider the matter resolved for your facility.

i

-l Sincerely,

'i Dennis M. Crutchfield, Chief; ' t,rt Operating Reactors Branch #P-Q, hs Division of Licensing Vg%

h 4,

j cc: See next pace w

f q

I

. e. % [-

Qh,p

\\f s

/

s, M

Ig g gd\\'

8108000p 5

/

,},JL;,,q[Fg1

,j, l

j,,,

! ! >~ =>L.DL;,/so;cc j DC0,RB #5,j, DL -

RB #5 li * ~ ~r)l RCay fie,1dl, ?RhfW6(4,,,,,,,

= ~ >\\. 3.\\.m....

,.7.1.. l... [s p. gl.....

U%

.........t.

p j

3.aC FC lu 3's -ic em NReaa c:o Q pp j C],4 Ig g g CQ p C C C 7,\\f acco nc-2,n

= - -

I

,(f* *EG Q[c, V

UNITED STATES NUCLEAR REGULATORY COMMISSION y $ ~c., j g t

/s -

/, E WASHINGTON, D. C. :0555

d M' v /ol January 28, 1981 Docket No. 50-29 LS05-81 044 Mr. James A. Kay Senior Engineer-Licensing Yankee Atomic Electric Company

[

1671 Worcester Road Framingham, Massachusetts 01701 Cear Mr. Kay:

[

SUBJECT:

REVIEW 0F POTENTIAL PROBLEMS WITH SURVEILLANCE PROCEDURES AND MULTIFLE FAILURES We have reviewed your letter of September 28, 1979 concerning l

inadvertent safety injection during surveillance testing at Yankee-Rowe.

{

We find that your response adequately addresses the concerns stated in our September 21, 1979 letter (which enclosed our June 26, 1979 letter) t and, therefore, we consider the matter resolved for your facility.

r Sincerely,

!hth.

Dennis M. Crutchfield, ief Operating Reactors Branch #5

.4 I,

Division of Licensing i l

?

cc: See next page r

r h

f

{

I l

.I E

Jib e

i i 6

.)

"o

1
i Mr. James A. Kay January 28, 1981 a

f CC Mr. Janes E. Tribble, President I

Yankee Atomic Electric Cocpany 25 Research Drive Westborough, Massachusetts 01581 Greenfield Comrunity College 1' College Drive

,~

Greenfield, Massachusetts 01301

~

Chai rman Board of Selectmen Town of Rowe Rowe, Massachusetts 01357 I

Energy Facilities Siting Council 14th Floor One Ashburton Place.

Boston, Massachusetts 02108 i s 4

Director, Criteria and Standards Division Office of Radiation Programs (ANR-460)

U. S. Environmental Protection Agency

- l Washington, D. C.

20460

' l U. S. Environmental Protection Agency Region I Office ATTN: EIS COORDINATOR JFK Federal Building Boston, Massachusetts 02203 Resident Inspector Yankee Rowe Nuclear Power Station c/o U.S. NLC Post Office Box 28 Monroe Bridge, Massachusetts 01350 1

.